1
|
Rodrigues J, Amin A, Chandra S, Mulla NJ, Nayak GS, Rai S, Ray S, Mahato KK. Machine Learning Enabled Photoacoustic Spectroscopy for Noninvasive Assessment of Breast Tumor Progression In Vivo: A Preclinical Study. ACS Sens 2024; 9:589-601. [PMID: 38288735 PMCID: PMC10897932 DOI: 10.1021/acssensors.3c01085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Revised: 11/25/2023] [Accepted: 01/17/2024] [Indexed: 02/24/2024]
Abstract
Breast cancer is a dreaded disease affecting women the most in cancer-related deaths over other cancers. However, early diagnosis of the disease can help increase survival rates. The existing breast cancer diagnosis tools do not support the early diagnosis of the disease. Therefore, there is a great need to develop early diagnostic tools for this cancer. Photoacoustic spectroscopy (PAS), being very sensitive to biochemical changes, can be relied upon for its application in detecting breast tumors in vivo. With this motivation, in the current study, an aseptic chamber integrated photoacoustic (PA) probe was designed and developed to monitor breast tumor progression in vivo, established in nude mice. The device served the dual purpose of transporting tumor-bearing animals to the laboratory from the animal house and performing PA experiments in the same chamber, maintaining sterility. In the current study, breast tumor was induced in the nude mice by MCF-7 cells injection and the corresponding PA spectra at different time points (day 0, 5, 10, 15, and 20) of tumor progression in vivo in the same animals. The recorded photoacoustic spectra were subsequently preprocessed, wavelet-transformed, and subjected to filter-based feature selection algorithm. The selected top 20 features, by minimum redundancy maximum relevance (mRMR) algorithm, were then used to build an input feature matrix for machine learning (ML)-based classification of the data. The performance of classification models demonstrated 100% specificity, whereas the sensitivity of 95, 100, 92.5, and 85% for the time points, day 5, 10, 15, and 20, respectively. These results suggest the potential of PA signal-based classification of breast tumor progression in a preclinical model. The PA signal contains information on the biochemical changes associated with disease progression, emphasizing its translational strength toward early disease diagnosis.
Collapse
Affiliation(s)
- Jackson Rodrigues
- Department
of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Karnataka, Manipal 576104, India
| | - Ashwini Amin
- Department
of Computer Science and Engineering, Manipal
Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, India
| | - Subhash Chandra
- Department
of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Karnataka, Manipal 576104, India
| | - Nitufa J. Mulla
- Department
of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Karnataka, Manipal 576104, India
| | - G. Subramanya Nayak
- Department
of Electronics and Communication, Manipal
Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, India
| | - Sharada Rai
- Department
of Pathology, Kasturba Medical College Mangalore,
Manipal Academy of Higher Education, Karnataka, Manipal 576104, India
| | - Satadru Ray
- Department
of Surgery, Kasturba Medical College, Manipal
Academy of Higher Education, Karnataka,Manipal 576104, India
| | - Krishna Kishore Mahato
- Department
of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Karnataka, Manipal 576104, India
| |
Collapse
|
2
|
Liu H, Wang M, Ji F, Jiang Y, Yang M. Mini review of photoacoustic clinical imaging: a noninvasive tool for disease diagnosis and treatment evaluation. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:S11522. [PMID: 38230369 PMCID: PMC10790789 DOI: 10.1117/1.jbo.29.s1.s11522] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 12/05/2023] [Accepted: 12/14/2023] [Indexed: 01/18/2024]
Abstract
Significance Photoacoustic (PA) imaging is an imaging modality that integrates anatomical, functional, metabolic, and histologic insights. It has been a hot topic of medical research and draws extensive attention. Aim This review aims to explore the applications of PA clinical imaging in human diseases, highlighting recent advancements. Approach A systemic survey of the literature concerning the clinical utility of PA imaging was conducted, with a particular focus on its application in tumors, autoimmune diseases, inflammatory conditions, and endocrine disorders. Results PA imaging is emerging as a valuable tool for human disease investigation. Information provided by PA imaging can be used for diagnosis, grading, and prognosis in multiple types of tumors including breast tumors, ovarian neoplasms, thyroid nodules, and cutaneous malignancies. PA imaging facilitates the monitoring of disease activity in autoimmune and inflammatory diseases such as rheumatoid arthritis, systemic sclerosis, arteritis, and inflammatory bowel disease by capturing dynamic functional alterations. Furthermore, its unique capability of visualizing vascular structure and oxygenation levels aids in assessing diabetes mellitus comorbidities and thyroid function. Conclusions Despite extant challenges, PA imaging offers a promising noninvasive tool for precision disease diagnosis, long-term evaluation, and prognosis anticipation, making it a potentially significant imaging modality for clinical practice.
Collapse
Affiliation(s)
- Huazhen Liu
- Chinese Academy of Medical Sciences and Peking Union Medical College, Peking Union Medical College Hospital, Department of Ultrasound, Beijing, China
| | - Ming Wang
- Chinese Academy of Medical Sciences and Peking Union Medical College, Peking Union Medical College Hospital, Department of Ultrasound, Beijing, China
| | - Fei Ji
- Chinese Academy of Medical Sciences and Peking Union Medical College, Peking Union Medical College Hospital, Department of Ultrasound, Beijing, China
| | - Yuxin Jiang
- Chinese Academy of Medical Sciences and Peking Union Medical College, Peking Union Medical College Hospital, Department of Ultrasound, Beijing, China
| | - Meng Yang
- Chinese Academy of Medical Sciences and Peking Union Medical College, Peking Union Medical College Hospital, Department of Ultrasound, Beijing, China
| |
Collapse
|
3
|
Ramírez-Chavarría RG, Pérez-Pacheco A, Terán E, Quispe-Siccha RM. Study of Polyvinyl Alcohol Hydrogels Applying Physical-Mechanical Methods and Dynamic Models of Photoacoustic Signals. Gels 2023; 9:727. [PMID: 37754408 PMCID: PMC10529391 DOI: 10.3390/gels9090727] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 08/23/2023] [Accepted: 08/29/2023] [Indexed: 09/28/2023] Open
Abstract
This study aims to analyze the physical-mechanical properties and dynamic models of tissue-simulating hydrogels, specifically the photoacoustic (PA) response signals, by varying the concentrations of polyvinyl alcohol (PVA) and molecular weight (MW). A state-space model (SSM) is proposed to study the PVA hydrogels to retrieve the PA-related signal's damping ratio and natural frequency. Nine box-shaped PVA hydrogels containing saline solution were used, with five concentrations of PVA (7, 9, 12, 15, 20%) for MW1 and four for MW2. The results indicated that the concentration of PVA and MW played an important role in the PA wave's amplitude, arrival time, and speed of sound over the hydrogels. The SSM parameters showed that increasing PVA and MW concentrations improved the hydrogels' ability to absorb and transfer energy under the PA effect. These parameters were also found to be correlated with density and modulus of elasticity. Additionally, the concentrations of PVA and MW affected the absorption and optical scattering coefficients. The physical-mechanical properties, including porosity, density, and modulus of elasticity, improved as the concentration of PVA and MW increased. The ultimate goal of this study is to develop hydrogels as phantoms that can be used for tissue simulation and imaging.
Collapse
Affiliation(s)
| | - Argelia Pérez-Pacheco
- Research and Technological Development Unit, Research Department, General Hospital of Mexico “Dr. Eduardo Liceaga”, Mexico City 06726, Mexico;
| | - Emiliano Terán
- Faculty of Physical-Mathematical Sciences, Autonomous University of Sinaloa, Culiacan, Sinaloa 80040, Mexico;
| | - Rosa M. Quispe-Siccha
- Research and Technological Development Unit, Research Department, General Hospital of Mexico “Dr. Eduardo Liceaga”, Mexico City 06726, Mexico;
| |
Collapse
|
4
|
Park S, Villa U, Li F, Cam RM, Oraevsky AA, Anastasio MA. Stochastic three-dimensional numerical phantoms to enable computational studies in quantitative optoacoustic computed tomography of breast cancer. JOURNAL OF BIOMEDICAL OPTICS 2023; 28:066002. [PMID: 37347003 PMCID: PMC10281048 DOI: 10.1117/1.jbo.28.6.066002] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 05/18/2023] [Accepted: 05/22/2023] [Indexed: 06/23/2023]
Abstract
Significance When developing a new quantitative optoacoustic computed tomography (OAT) system for diagnostic imaging of breast cancer, objective assessments of various system designs through human trials are infeasible due to cost and ethical concerns. In prototype stages, however, different system designs can be cost-efficiently assessed via virtual imaging trials (VITs) employing ensembles of digital breast phantoms, i.e., numerical breast phantoms (NBPs), that convey clinically relevant variability in anatomy and optoacoustic tissue properties. Aim The aim is to develop a framework for generating ensembles of realistic three-dimensional (3D) anatomical, functional, optical, and acoustic NBPs and numerical lesion phantoms (NLPs) for use in VITs of OAT applications in the diagnostic imaging of breast cancer. Approach The generation of the anatomical NBPs was accomplished by extending existing NBPs developed by the U.S. Food and Drug Administration. As these were designed for use in mammography applications, substantial modifications were made to improve blood vasculature modeling for use in OAT. The NLPs were modeled to include viable tumor cells only or a combination of viable tumor cells, necrotic core, and peripheral angiogenesis region. Realistic optoacoustic tissue properties were stochastically assigned in the NBPs and NLPs. Results To advance optoacoustic and optical imaging research, 84 datasets have been released; these consist of anatomical, functional, optical, and acoustic NBPs and the corresponding simulated multi-wavelength optical fluence, initial pressure, and OAT measurements. The generated NBPs were compared with clinical data with respect to the volume of breast blood vessels and spatially averaged effective optical attenuation. The usefulness of the proposed framework was demonstrated through a case study to investigate the impact of acoustic heterogeneity on OAT images of the breast. Conclusions The proposed framework will enhance the authenticity of virtual OAT studies and can be widely employed for the investigation and development of advanced image reconstruction and machine learning-based methods, as well as the objective evaluation and optimization of the OAT system designs.
Collapse
Affiliation(s)
- Seonyeong Park
- University of Illinois Urbana-Champaign, Department of Bioengineering, Urbana, Illinois, United States
| | - Umberto Villa
- The University of Texas at Austin, Oden Institute for Computational Engineering and Sciences, Austin, Texas, United States
| | - Fu Li
- University of Illinois Urbana-Champaign, Department of Bioengineering, Urbana, Illinois, United States
| | - Refik Mert Cam
- University of Illinois Urbana-Champaign, Department of Electrical and Computer Engineering, Urbana, Illinois, United States
| | | | - Mark A. Anastasio
- University of Illinois Urbana-Champaign, Department of Bioengineering, Urbana, Illinois, United States
- University of Illinois Urbana-Champaign, Department of Electrical and Computer Engineering, Urbana, Illinois, United States
| |
Collapse
|
5
|
Rascevska E, Yip L, Omidi P, Brackstone M, Carson J. Investigating the feasibility of a hand-held photoacoustic imaging probe for margin assessment during breast conserving surgery. PHOTOACOUSTICS 2022; 28:100424. [PMID: 36386296 PMCID: PMC9650058 DOI: 10.1016/j.pacs.2022.100424] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Revised: 10/10/2022] [Accepted: 10/31/2022] [Indexed: 06/16/2023]
Abstract
Approximately 19 % of breast cancer patients undergoing breast conserving surgery (BCS) must return for a secondary surgery due to incomplete tumour removal. Our previous work demonstrated that the lower lipid content, characteristic of tumour tissue, was observed as regions of hypo-intense photoacoustic (PA) contrast. The goal of this work was to evaluate feasibility of a low-frequency, hand-held PA imaging probe for surgical margin assessment based on lipid content differences. Here, we describe (i) the design of a prototype hand-held PA imaging probe, (ii) the effect of limited-bandwidth on image contrast, (iii) accuracy towards hypo-intense contrast detection, (iv) the limited-view characteristics of the single sensor design, and (iv) early imaging results of an ex-vivo breast cancer specimen. The probe incorporates a single polyvinylidene fluoride acoustic sensor, a 1-to-4 optical fibre bundle and a polycarbonate axicon lens for light delivery. Imaging results on phantoms designed to mimic positive margins demonstrated the ability to detect gaps in optical absorption as small as 1 mm in width. Compared to images from a near full-view PAI system, the hand-held PAI probe had higher signal to noise ratio but suffered from negativity image artifacts. Lumpectomy specimen imaging showed that strong signals can be obtained from the fatty tissue. Taken together, the results show this imaging approach with a hand-held probe has potential for detection of residual breast cancer tissue during BCS; however, more work is needed to reduce the size of the probe to fit within the surgical cavity.
Collapse
Affiliation(s)
- E. Rascevska
- Imaging Program, Lawson Health Research Institute, 268 Grosvenor St., London N6A 4V2, ON, Canada
- School of Biomedical Engineering, Western University, 1151 Richmond St., London N6A 3K7, ON, Canada
| | - L.C.M. Yip
- Imaging Program, Lawson Health Research Institute, 268 Grosvenor St., London N6A 4V2, ON, Canada
- Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, 1151 Richmond St., London N6A 3K7, ON, Canada
| | - P. Omidi
- Imaging Program, Lawson Health Research Institute, 268 Grosvenor St., London N6A 4V2, ON, Canada
- School of Biomedical Engineering, Western University, 1151 Richmond St., London N6A 3K7, ON, Canada
| | - M. Brackstone
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University, 1151 Richmond St., London N6A 3K7, ON, Canada
- Department of Oncology, Schulich School of Medicine & Dentistry, The University of Western Ontario, 1151 Richmond St., N6A 3K7, London, ON, Canada
| | - J.J.L. Carson
- Imaging Program, Lawson Health Research Institute, 268 Grosvenor St., London N6A 4V2, ON, Canada
- School of Biomedical Engineering, Western University, 1151 Richmond St., London N6A 3K7, ON, Canada
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University, 1151 Richmond St., London N6A 3K7, ON, Canada
- Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, 1151 Richmond St., London N6A 3K7, ON, Canada
| |
Collapse
|
6
|
Liu S, Zhang R, Han T, Pan Y, Zhang G, Long X, Zhao C, Wang M, Li X, Yang F, Sang Y, Zhu L, He X, Li J, Zhang Y, Li C, Jiang Y, Yang M. Validation of photoacoustic/ultrasound dual imaging in evaluating blood oxygen saturation. BIOMEDICAL OPTICS EXPRESS 2022; 13:5551-5570. [PMID: 36425613 PMCID: PMC9664893 DOI: 10.1364/boe.469747] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 09/16/2022] [Accepted: 09/16/2022] [Indexed: 06/16/2023]
Abstract
Photoacoustic imaging (PAI) was performed to evaluate oxygen saturation (sO2) of blood-mimicking phantoms, femoral arteries in beagles, and radial arteries in humans at various sO2 plateaus. The accuracy (root mean square error, RMSE) of PAI sO2 compared with reference sO2 was calculated. In blood-mimicking phantoms, PAI achieved an accuracy of 1.49% and a mean absolute error (MAE) of 1.09% within 25 mm depth, and good linearity (R = 0.968; p < 0.001) was obtained between PAI sO2 and reference sO2. In canine femoral arteries, PAI achieved an accuracy of 2.16% and an MAE of 1.58% within 8 mm depth (R = 0.965; p < 0.001). In human radial arteries, PAI achieved an accuracy of 3.97% and an MAE of 3.28% in depth from 4 to 14 mm (R = 0.892; p < 0.001). For PAI sO2 evaluation at different depths in healthy volunteers, the RMSE accuracy of PAI sO2 increased from 2.66% to 24.96% with depth increasing from 4 to 14 mm. Through the multiscale method, we confirmed the feasibility of the hand-held photoacoustic/ultrasound (PA/US) in evaluating sO2. These results demonstrate the potential clinical value of PAI in evaluating blood sO2. Consequently, protocols for verifying the feasibility of medical devices based on PAI may be established.
Collapse
Affiliation(s)
- Sirui Liu
- Department of Ultrasound, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
- The authors contributed equally to this manuscript
| | - Rui Zhang
- Department of Ultrasound, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
- The authors contributed equally to this manuscript
| | - Tao Han
- Department of Biomedical Engineering, College of Engineering, Peking University, Beijing, China
| | - Yinhao Pan
- Mindray Bio-Medical Electronics Co., Ltd., Shenzhen, China
| | - Guangjie Zhang
- Department of Biomedical Engineering, College of Engineering, Peking University, Beijing, China
| | - Xing Long
- Department of Biomedical Engineering, College of Engineering, Peking University, Beijing, China
| | - Chenyang Zhao
- Department of Ultrasound, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
| | - Ming Wang
- Department of Ultrasound, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
| | - Xuelan Li
- Department of Ultrasound, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
| | - Fang Yang
- Mindray Bio-Medical Electronics Co., Ltd., Shenzhen, China
| | - Yuchao Sang
- Mindray Bio-Medical Electronics Co., Ltd., Shenzhen, China
| | - Lei Zhu
- Mindray Bio-Medical Electronics Co., Ltd., Shenzhen, China
| | - Xujin He
- Mindray Bio-Medical Electronics Co., Ltd., Shenzhen, China
| | - Jianchu Li
- Department of Ultrasound, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
| | - Yewei Zhang
- Hepatopancreatobiliary Center, The Second Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Changhui Li
- Department of Biomedical Engineering, College of Engineering, Peking University, Beijing, China
| | - Yuxin Jiang
- Department of Ultrasound, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
| | - Meng Yang
- Department of Ultrasound, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
| |
Collapse
|
7
|
Lin L, Wang LV. The emerging role of photoacoustic imaging in clinical oncology. Nat Rev Clin Oncol 2022; 19:365-384. [PMID: 35322236 DOI: 10.1038/s41571-022-00615-3] [Citation(s) in RCA: 97] [Impact Index Per Article: 48.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/23/2022] [Indexed: 12/13/2022]
Abstract
Clinical oncology can benefit substantially from imaging technologies that reveal physiological characteristics with multiscale observations. Complementing conventional imaging modalities, photoacoustic imaging (PAI) offers rapid imaging (for example, cross-sectional imaging in real time or whole-breast scanning in 10-15 s), scalably high levels of spatial resolution, safe operation and adaptable configurations. Most importantly, this novel imaging modality provides informative optical contrast that reveals details on anatomical, functional, molecular and histological features. In this Review, we describe the current state of development of PAI and the emerging roles of this technology in cancer screening, diagnosis and therapy. We comment on the performance of cutting-edge photoacoustic platforms, and discuss their clinical applications and utility in various clinical studies. Notably, the clinical translation of PAI is accelerating in the areas of macroscopic and mesoscopic imaging for patients with breast or skin cancers, as well as in microscopic imaging for histopathology. We also highlight the potential of future developments in technological capabilities and their clinical implications, which we anticipate will lead to PAI becoming a desirable and widely used imaging modality in oncological research and practice.
Collapse
Affiliation(s)
- Li Lin
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Lihong V Wang
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA, USA. .,Department of Electrical Engineering, California Institute of Technology, Pasadena, CA, USA.
| |
Collapse
|
8
|
Chen C, Liu S, Zhao C, Wang R, Yu N, Long X, Wang Y, Yang F, Sun J, Lu ZL, Xia Y, Jiang Y, Yang M. Activity of keloids evaluated by multimodal photoacoustic/ultrasonic imaging system. PHOTOACOUSTICS 2021; 24:100302. [PMID: 34540586 PMCID: PMC8441086 DOI: 10.1016/j.pacs.2021.100302] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/23/2021] [Revised: 08/25/2021] [Accepted: 09/06/2021] [Indexed: 06/13/2023]
Abstract
Multiple objective assessments have been used to assess the activity of keloids to compare different therapeutic regimens and facilitate the best individual treatment choice for patients, but none of them are standardized. A multimodal photoacoustic/ultrasonic (PA/US) imaging system, including photoacoustic imaging, elastography, ultra-micro-angiography, and conventional US technologies (gray scale US, color Doppler US, and power Doppler US), was applied to evaluate keloids by a radiologist. Growing stages were defined by patients, and Vancouver Scar Scale (VSS) was assessed by a plastic surgeon. A comprehensive model based on multimodal ultrasound parameters (poor-echo pattern, high vascular density, decreased elasticity, and low SO2 within the keloid) and VSS might be a potential indicator of active keloids, comparing with VSS alone. The multimodal PA/US imaging system could be a promising technique for keloids assessment.
Collapse
Affiliation(s)
- Cheng Chen
- Department of Ultrasonography, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Sirui Liu
- Department of Ultrasonography, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Chenyang Zhao
- Department of Ultrasonography, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Ruojiao Wang
- Department of Ultrasonography, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Nanze Yu
- Department of Plastic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Xiao Long
- Department of Plastic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Youbin Wang
- Department of Plastic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Fang Yang
- Mindray Bio-Medical Electronics Co., Ltd., Shenzhen, China
| | - Jie Sun
- Mindray Bio-Medical Electronics Co., Ltd., Shenzhen, China
| | - Zhao Ling Lu
- Mindray North American Innovation Center, San Jose, CA, United States
| | - Yu Xia
- Department of Ultrasonography, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Yuxin Jiang
- Department of Ultrasonography, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Meng Yang
- Department of Ultrasonography, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|
9
|
Yang H, Zhang T, Tao C, Liu X. Multispectral photoacoustic holography of elastomers from a bright background. OPTICS LETTERS 2021; 46:5071-5074. [PMID: 34598271 DOI: 10.1364/ol.441660] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Accepted: 09/19/2021] [Indexed: 06/13/2023]
Abstract
Photoacoustic imaging of elastomers has important biomedical value. However, a bright background, e.g., blood vessels in living tissue, brings a challenge for photoacoustic elastography. In this study, we predicted that the spectrum of photoacoustic signals from elastomers with high elasticity could appear as narrow peaks at the eigen-frequencies of elastomers, but the signals from a bright background, e.g., blood vessel, show flat broadband spectrum for their low-quality factor. Even when the two kinds of signals are mixed together, the signals from elastomers can be identified from the spectrum since they present as convex narrow peaks on a wide base. Based on this factor, we propose a multispectral photoacoustic holography to realize selective imaging of tiny elastomers. This method recovers the image only using several frequency components in photoacoustic signals, instead of the whole-band signal. Since these narrow peaks in the spectrum correspond to the eigen-vibration of elastomers, the proposed method can highlight the elastomers with high elasticity from a bright background with low elasticity. The method was validated by experiments. This study might be helpful to localize elastic anomalous areas in the tissue, such as calcification in the vascular network, microcalcification in a tumor, and implants.
Collapse
|
10
|
Na S, Wang LV. Photoacoustic computed tomography for functional human brain imaging [Invited]. BIOMEDICAL OPTICS EXPRESS 2021; 12:4056-4083. [PMID: 34457399 PMCID: PMC8367226 DOI: 10.1364/boe.423707] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 06/05/2021] [Accepted: 06/08/2021] [Indexed: 05/02/2023]
Abstract
The successes of magnetic resonance imaging and modern optical imaging of human brain function have stimulated the development of complementary modalities that offer molecular specificity, fine spatiotemporal resolution, and sufficient penetration simultaneously. By virtue of its rich optical contrast, acoustic resolution, and imaging depth far beyond the optical transport mean free path (∼1 mm in biological tissues), photoacoustic computed tomography (PACT) offers a promising complementary modality. In this article, PACT for functional human brain imaging is reviewed in its hardware, reconstruction algorithms, in vivo demonstration, and potential roadmap.
Collapse
Affiliation(s)
- Shuai Na
- Caltech Optical Imaging Laboratory, Andrew
and Peggy Cherng Department of Medical Engineering,
California Institute of Technology, 1200
East California Boulevard, Pasadena, CA 91125, USA
| | - Lihong V. Wang
- Caltech Optical Imaging Laboratory, Andrew
and Peggy Cherng Department of Medical Engineering,
California Institute of Technology, 1200
East California Boulevard, Pasadena, CA 91125, USA
- Caltech Optical Imaging Laboratory,
Department of Electrical Engineering, California
Institute of Technology, 1200 East California Boulevard,
Pasadena, CA 91125, USA
| |
Collapse
|