1
|
Svede A, Semjonova S, Ganebnaya A, Puhova L, Baig KF, Kucika A, Ikaunieks G, Panke K, Gromov D. Application of a New Device for Vision Relaxation in Computer Users. Vision (Basel) 2024; 8:40. [PMID: 39051226 PMCID: PMC11270284 DOI: 10.3390/vision8030040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2024] [Revised: 06/17/2024] [Accepted: 06/19/2024] [Indexed: 07/27/2024] Open
Abstract
This study aims to explore the potential of a novel EYE ROLL device designed to facilitate guided vision relaxation exercises in an open space. A prospective study was performed on 89 participants who perform screenwork for at least four hours daily. All participants were randomly divided into three groups: a Control group with no exercising, a Manual group undertook manual vision relax ation exercises, and an Eyeroll group engaged in EYE ROLL device-assisted vision relaxation exercises. Each participant underwent three evaluations (an initial baseline assessment, a 4-week follow-up, and an 8-week follow-up) with four assessment tools: a comprehensive vision examination, an in-depth questionnaire, saccadic eye movement recordings, and objective accommodation measurements. There was a statistically significant decrease (35% and above) in complaint scores at the 4-week follow-up in both training groups. Although statistically insignificant, complaints continued to decrease after an 8-week period. No significant changes were observed in clinical or objective accommodative parameters. Some variation of visual functions was observed in all groups due to repeated measures. Vision relaxation exercises combined with proper vision ergonomics and working habits can reduce asthenopic complaints. The EYE ROLL device presents a promising tool for integrating these exercises into the working environment.
Collapse
Affiliation(s)
- Aiga Svede
- Department of Optometry and Vision Science, Faculty of Physics, Mathematics and Optometry, University of Latvia, Jelgavas Street 1, LV-1004 Riga, Latvia (A.G.); (A.K.); (G.I.); (K.P.)
| | - Svetlana Semjonova
- Department of Optometry and Vision Science, Faculty of Physics, Mathematics and Optometry, University of Latvia, Jelgavas Street 1, LV-1004 Riga, Latvia (A.G.); (A.K.); (G.I.); (K.P.)
| | - Angelina Ganebnaya
- Department of Optometry and Vision Science, Faculty of Physics, Mathematics and Optometry, University of Latvia, Jelgavas Street 1, LV-1004 Riga, Latvia (A.G.); (A.K.); (G.I.); (K.P.)
| | - Liga Puhova
- Department of Optometry and Vision Science, Faculty of Physics, Mathematics and Optometry, University of Latvia, Jelgavas Street 1, LV-1004 Riga, Latvia (A.G.); (A.K.); (G.I.); (K.P.)
| | - Kulsum Fatima Baig
- Department of Optometry and Vision Science, Faculty of Physics, Mathematics and Optometry, University of Latvia, Jelgavas Street 1, LV-1004 Riga, Latvia (A.G.); (A.K.); (G.I.); (K.P.)
| | - Alina Kucika
- Department of Optometry and Vision Science, Faculty of Physics, Mathematics and Optometry, University of Latvia, Jelgavas Street 1, LV-1004 Riga, Latvia (A.G.); (A.K.); (G.I.); (K.P.)
| | - Gatis Ikaunieks
- Department of Optometry and Vision Science, Faculty of Physics, Mathematics and Optometry, University of Latvia, Jelgavas Street 1, LV-1004 Riga, Latvia (A.G.); (A.K.); (G.I.); (K.P.)
| | - Karola Panke
- Department of Optometry and Vision Science, Faculty of Physics, Mathematics and Optometry, University of Latvia, Jelgavas Street 1, LV-1004 Riga, Latvia (A.G.); (A.K.); (G.I.); (K.P.)
| | - Dmitry Gromov
- Department of Mathematics, Faculty of Physics, Mathematics and Optometry, University of Latvia, Jelgavas Street 3, LV-1004 Riga, Latvia;
| |
Collapse
|
2
|
Pourreza Ghoushchi V, Mompeán J, Prieto PM, Artal P. Contrast sensitivity is resilient to induced fast periodic defocus oscillations. BIOMEDICAL OPTICS EXPRESS 2024; 15:3848-3858. [PMID: 38867768 PMCID: PMC11166443 DOI: 10.1364/boe.521340] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/08/2024] [Revised: 05/08/2024] [Accepted: 05/09/2024] [Indexed: 06/14/2024]
Abstract
This study investigates the potential effects of periodic defocus oscillations on contrast sensitivity. Sinusoidal fluctuations at 5, 15, and 25 Hz, with defocus peak-to-valley values ranging from 0.15 to 3 D, were induced by means of a focus-tunable lens after calibrating its dynamic behavior. Monocular contrast sensitivity was measured on five young emmetropic subjects. The experimental data shows that contrast sensitivity loss due to defocus fluctuations is low for a wide range of frequencies and amplitudes. Only for the more severe case studied (25 Hz, ± 1.5 D) contrast threshold showed a clear increase in most subjects. Qualitative comparison of the empirical data with a simulation of modulation loss due to time integration of defocused retinal point spread functions, suggests a short integration time by the eye for defocus blur, around or even below a hundredth of a second.
Collapse
Affiliation(s)
- Vahid Pourreza Ghoushchi
- Laboratorio de Óptica, Instituto Universitario de Investigación en Óptica y Nanofísica, Universidad de Murcia, Campus de Espinardo (Edificio 34), E-30100 Murcia, Spain
| | - Juan Mompeán
- Laboratorio de Óptica, Instituto Universitario de Investigación en Óptica y Nanofísica, Universidad de Murcia, Campus de Espinardo (Edificio 34), E-30100 Murcia, Spain
| | - Pedro M. Prieto
- Laboratorio de Óptica, Instituto Universitario de Investigación en Óptica y Nanofísica, Universidad de Murcia, Campus de Espinardo (Edificio 34), E-30100 Murcia, Spain
| | - Pablo Artal
- Laboratorio de Óptica, Instituto Universitario de Investigación en Óptica y Nanofísica, Universidad de Murcia, Campus de Espinardo (Edificio 34), E-30100 Murcia, Spain
| |
Collapse
|
3
|
Liu Y, Liu L, Liu M, Wang X, Jin C, Ni B, Ke B. Change in three-dimensional choroidal vessel network after AR device assisted 1-hour visual task in 2D/3D mode in young healthy subjects. Acta Ophthalmol 2024; 102:e117-e125. [PMID: 37088997 DOI: 10.1111/aos.15671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 03/07/2023] [Accepted: 03/27/2023] [Indexed: 04/25/2023]
Abstract
PURPOSE The purpose of the study was to investigate the changes of choroidal blood perfusion in different layers and quadrants and its possible related factors after 1 h visual task by augmented reality (AR) device in two-dimensional (2D) and three-dimensional (3D) mode, respectively. METHODS Thirty healthy subjects aged 22-37 years watched the same video source in 2D and 3D mode separately using AR glasses for 1 h with a one-week interval. Swept-source optical coherence tomography angiography (SS-OCTA) was performed before and immediately after watching to acquire choroidal thickness (ChT), three-dimensional choroidal vascularity index (CVI) of large- and middle-sized choroidal vessels and choriocapillaris flow voids (FV%) at macular and peripapillary area. Near point of accommodation (NPA) and accommodative facility (AF) were examined to evaluate the accommodative ability. Pupil diameters by infrared-automated pupillometer under scotopic, mesopic and photopic condition were also obtained. RESULTS Compared with pre-visual task, the subfoveal CVI decreased from 0.406 ± 0.097 to 0.360 ± 0.102 after 2D watching (p < 0.001) and to 0.368 ± 0.102 after 3D watching (p = 0.002). Pupil sizes under different illuminance conditions became smaller after both 2D and 3D watching (all p < 0.001). AF increased after both 2D and 3D watching (both p < 0.05). NPA receded in post-3D watching (p = 0.017) while a not significant tendency was observed in post-2D. CONCLUSION A reduction in subfoveal choroidal blood flow accompanied with pupil constriction was observed immediately after 1 h visual task using AR glasses in 2D and 3D mode. Accommodative facility improved after 2D and 3D watching with AR glasses, whereas decrease in the maximum accommodation power was only found in 3D mode.
Collapse
Affiliation(s)
- Yuying Liu
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- National Clinical Research Center for Eye Diseases, Shanghai, China
- Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai, China
- Shanghai Engineering Center for Visual Science and Photo Medicine, Shanghai, China
- Shanghai Engineering Center for Precise Diagnosis and Treatment of Eye Diseases, Shanghai, China
| | - Lu Liu
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- National Clinical Research Center for Eye Diseases, Shanghai, China
- Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai, China
- Shanghai Engineering Center for Visual Science and Photo Medicine, Shanghai, China
- Shanghai Engineering Center for Precise Diagnosis and Treatment of Eye Diseases, Shanghai, China
| | - Mingming Liu
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- National Clinical Research Center for Eye Diseases, Shanghai, China
- Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai, China
- Shanghai Engineering Center for Visual Science and Photo Medicine, Shanghai, China
- Shanghai Engineering Center for Precise Diagnosis and Treatment of Eye Diseases, Shanghai, China
| | - Xuetong Wang
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- National Clinical Research Center for Eye Diseases, Shanghai, China
- Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai, China
- Shanghai Engineering Center for Visual Science and Photo Medicine, Shanghai, China
- Shanghai Engineering Center for Precise Diagnosis and Treatment of Eye Diseases, Shanghai, China
| | - Chengcheng Jin
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- National Clinical Research Center for Eye Diseases, Shanghai, China
- Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai, China
- Shanghai Engineering Center for Visual Science and Photo Medicine, Shanghai, China
- Shanghai Engineering Center for Precise Diagnosis and Treatment of Eye Diseases, Shanghai, China
| | - Bingbing Ni
- Department of Electronic Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Bilian Ke
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- National Clinical Research Center for Eye Diseases, Shanghai, China
- Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai, China
- Shanghai Engineering Center for Visual Science and Photo Medicine, Shanghai, China
- Shanghai Engineering Center for Precise Diagnosis and Treatment of Eye Diseases, Shanghai, China
| |
Collapse
|
4
|
Espinosa J, Archid K, Pérez J, Perales E. Using a video-based eye tracker to analyse the binocular near-reflex dynamics response. Ophthalmic Physiol Opt 2023; 43:1540-1549. [PMID: 37470168 DOI: 10.1111/opo.13203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 07/04/2023] [Accepted: 07/05/2023] [Indexed: 07/21/2023]
Abstract
PURPOSE This study presents a novel video-based eye-tracking system for analysing the dynamics of the binocular near-reflex response. The system enables the simultaneous measurement of convergence, divergence and pupillary size during accommodation and disaccommodation to aid the comprehensive understanding of the three-component near-reflex. METHODS A high-speed (90 Hz) video-based eye tracker was used to capture changes in eye gaze and pupil radius in 15 participants in response to altering stimulus conditions. An offline analysis involved separating the gaze vector components and pupil radius, which were fitted to a hyperbolic tangent function to characterise the dynamics of the near-reflex process. RESULTS Significant differences in the temporal parameters of the pupil radius were observed between the near-to-far and far-to-near vision changes, with faster miosis compared with mydriasis. Additionally, differences in response times were found between gaze angle components, with longer convergence times compared to changes in the vertical direction (saccades). The steady-state values of the gaze components and pupil radius were in line with theoretical expectations and previous reports. CONCLUSIONS The proposed system provides a non-invasive, portable and cost-effective method for evaluating near-reflex dynamics under natural viewing conditions using a video-based eye tracker. The sampling rate ensures the accurate assessment of vergence eye movements and pupillary dynamics. By simultaneously measuring eye convergence, divergence and pupil size, the system offers a more comprehensive assessment of the near-reflex response. This makes it a valuable tool for clinical diagnosis, research studies and investigating the effects of near work on the visual system.
Collapse
Affiliation(s)
- Julián Espinosa
- Departamento de Óptica, Farmacología y Anatomía, Universidad de Alicante, Alicante, Spain
- Instituto Universitario de Física, Aplicada a las Ciencias y las Tecnologías, Universidad de Alicante, Alicante, Spain
| | - Kauzar Archid
- Departamento de Óptica, Farmacología y Anatomía, Universidad de Alicante, Alicante, Spain
| | - Jorge Pérez
- Departamento de Óptica, Farmacología y Anatomía, Universidad de Alicante, Alicante, Spain
- Instituto Universitario de Física, Aplicada a las Ciencias y las Tecnologías, Universidad de Alicante, Alicante, Spain
| | - Esther Perales
- Departamento de Óptica, Farmacología y Anatomía, Universidad de Alicante, Alicante, Spain
- Instituto Universitario de Física, Aplicada a las Ciencias y las Tecnologías, Universidad de Alicante, Alicante, Spain
| |
Collapse
|
5
|
Zhu J, Guo D, Jin L, Zhou T, Shan S, Zhu H, Zhang L, Tong J, Shen Y. Comparison of higher-order aberrations between implantable collamer lens V4c implantation and simulated spectacle correction in patients with high myopia. J Fr Ophtalmol 2023:S0181-5512(23)00145-6. [PMID: 37149460 DOI: 10.1016/j.jfo.2022.11.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2022] [Revised: 11/13/2022] [Accepted: 11/21/2022] [Indexed: 05/08/2023]
Abstract
PURPOSE To investigate the differences in higher-order aberrations between non-toric or toric implantable collamer lens (ICL or TICL) V4c implantation and simulated spectacle correction. METHODS Patients with high myopia who underwent ICL/TICL V4c implantation were enrolled. The "total no defocus" pattern of iTrace aberrometry to simulate the condition of spectacle correction was measured before ICL/TICL implantation, and higher-order aberrations in this condition were compared to those 3 months after surgery. Related factors with changes in coma were comprehensively analyzed. RESULTS A total of 89 right eyes of 89 patients were included. Compared to simulated spectacle correction, total-eye coma (P<0.0001 ICL, P<0.0001 TICL) and internal coma (P<0.0001 ICL, P<0.001 TICL) decreased in the ICL- and TICL-treated groups after surgery. Total-eye secondary astigmatism (P<0.0001 ICL, P=0.007 TICL) and internal secondary astigmatism (P<0.0001 ICL, P=0.009 TICL) were also decreased in both groups postoperatively. Spherical error showed positive correlations with variation in total-eye coma (r=0.37, P=0.004 ICL; r=0.56, P=0.001 TICL) and internal coma (r=0.30, P=0.02 ICL and r=0.45, P=0.01 TICL). Axial length revealed negative correlations with changes in total-eye coma (r=-0.45, P<0.001 ICL; r=-0.39, P=0.03 TICL) and internal coma (r=-0.28, P=0.03 ICL and r=-0.42, P=0.02 TICL). CONCLUSIONS Both ICL- and TICL-treated groups demonstrated a decrease in coma and secondary astigmatism after 3 months, postoperatively. ICL/TICL may confer a compensatory effect on coma aberration and secondary astigmatism. Patients with a higher myopia achieved a greater improvement in coma and may benefit more from ICL/TICL implantation than from spectacle correction implantation than from spectacle correction.
Collapse
Affiliation(s)
- J Zhu
- Department of Ophthalmology, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, China; Clinical Research Center, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, China
| | - D Guo
- Department of Ophthalmology, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, China; Clinical Research Center, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, China
| | - L Jin
- Department of Ophthalmology, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, China; Clinical Research Center, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, China
| | - T Zhou
- Department of Ophthalmology, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, China; Clinical Research Center, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, China
| | - S Shan
- Department of Ophthalmology, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, China; Clinical Research Center, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, China
| | - H Zhu
- Department of Ophthalmology, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, China; Clinical Research Center, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, China
| | - L Zhang
- Department of Ophthalmology, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, China; Clinical Research Center, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, China
| | - J Tong
- Department of Ophthalmology, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, China; Clinical Research Center, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, China.
| | - Y Shen
- Department of Ophthalmology, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, China; Clinical Research Center, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, China.
| |
Collapse
|
6
|
Li K, Li X, Wang Q, Wang L, Huang Y. Kinetic pupillary size using Pentacam in myopia. Front Neurosci 2022; 16:981436. [PMID: 36507361 PMCID: PMC9732367 DOI: 10.3389/fnins.2022.981436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Accepted: 11/10/2022] [Indexed: 11/26/2022] Open
Abstract
Purpose To compare if the kinetic pupillary changes differs between high myopia (HM) and low/moderate myopia by Pentacam. Setting Chinese People's Liberation Army (PLA) General Hospital, Beijing, China. Design Comparative study. Methods In this cross-sectional retrospective study, 44 eyes of 44 patients were recruited in the Refractive Surgery Center of Chinese PLA General Hospital. Eyes were divided into two groups according to the refractive error: low/moderate myopia (22 eyes; -2.99 ± 1.09 D) and HM (22 eyes, -12.93 ± 3.44 D). At the beginning of the experiment, we made trials of scanning one false pupil by Pentacam. All patients underwent the Pentacam examination three times. Pupillary diameters (PD) during the scan process and other parameters were measured using the Pentacam. Coefficient variations of PD (CV) during the different scanning periods were analyzed comparatively between the two groups. Results Pentacam once time output 25 Scheimpflug images, with 13 ones during the period from 1st to 1.5th s and 12 ones during the period from 2.5th to 3rd s after the scanning onset. For the spatial order on all the 25 meridians, 13 Scheimpflug images came out when the Pentacam rotated from 60° to 153°meridians and the remaining 12 Scheimpflug images from 161° to 245° meridians. Among pupillary parameters, no statistical significance existed in PD25, PD13, and PD12 (pupil diameter's mean from all, former 13 and remaining 12 of 25 Scheimpflug images, respectively) (P > 0.05) between the two groups. However, there were statistically significant differences in CV25 and CV13 (coefficient variation of the pupil diameters from all and former 13 of 25 images, respectively) (P < 0.001), with no statistical significance in CV12 (coefficient variation of the pupil diameters from remaining 12 of 25 images) between both groups. Conclusion Twenty-five Scheimpflug images on Pentacam had the temporal and the spatial orders. CV in eyes with HM was lower than that in eyes with low/moderate myopia in a certain period of the Pentacam scan. Kinetic pupillary size in HM changed more slowly than that in low/moderate myopia during some scanning period analogous to the phasic response of the pupil reflex.
Collapse
Affiliation(s)
- Kaixiu Li
- Medical School of Chinese People’s Liberation Army (PLA), Beijing, China
- Department of Ophthalmology, The First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Xiaoqi Li
- Medical School of Chinese People’s Liberation Army (PLA), Beijing, China
- Department of Ophthalmology, The First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Qun Wang
- Department of Ophthalmology, The Third Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Liqiang Wang
- Department of Ophthalmology, The Third Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Yifei Huang
- Department of Ophthalmology, The Third Medical Center, Chinese PLA General Hospital, Beijing, China
| |
Collapse
|