1
|
Mieites V, Anichini G, Qi J, O'Neill K, Conde OM, Elson DS. PoLambRimetry: a multispectral polarimetric atlas of lamb brain. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:096002. [PMID: 39290462 PMCID: PMC11406468 DOI: 10.1117/1.jbo.29.9.096002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Figures] [Subscribe] [Scholar Register] [Received: 05/09/2024] [Revised: 08/02/2024] [Accepted: 08/19/2024] [Indexed: 09/19/2024]
Abstract
Significance Mueller matrix imaging (MMI) is a comprehensive form of polarization imaging useful for assessing structural changes. However, there is limited literature on the polarimetric properties of brain specimens, especially with multispectral analysis. Aim We aim to employ multispectral MMI for an exhaustive polarimetric analysis of brain structures, providing a reference dataset for future studies and enhancing the understanding of brain anatomy for clinicians and researchers. Approach A multispectral wide-field MMI system was used to measure six fresh lamb brain specimens. Multiple decomposition methods (forward polar, symmetric, and differential) and polarization invariants (indices of polarimetric purity and anisotropy coefficients) have been calculated to obtain a complete polarimetric description of the samples. A total of 16 labels based on major brain structures, including grey matter (GM) and white matter (WM), were identified. K -nearest neighbors classification was used to distinguish between GM and WM and validate the feasibility of MMI for WM identification. Results As the wavelength increases, both depolarization and retardance increase, suggesting enhanced tissue penetration into deeper layers. Moreover, utilizing multiple wavelengths allowed us to track dynamic shifts in the optical axis of retardance within the brain tissue, providing insights into morphological changes in WM beneath the cortical surface. The use of multispectral data for classification outperformed all results obtained with single-wavelength data and provided over 95% accuracy for the test dataset. Conclusions The consistency of these observations highlights the potential of multispectral wide-field MMI as a non-invasive and effective technique for investigating the brain's architecture.
Collapse
Affiliation(s)
- Verónica Mieites
- University of Cantabria, Photonics Engineering Group, Santander, Spain
- Valdecilla Health Research Institute (IDIVAL), Santander, Spain
| | - Giulio Anichini
- Imperial College London, Department of Brain Sciences, London, United Kingdom
| | - Ji Qi
- Research Centre for Fundamental Research, Zhejiang Lab, Hangzhou, China
| | - Kevin O'Neill
- Imperial College London, Department of Brain Sciences, London, United Kingdom
| | - Olga M Conde
- University of Cantabria, Photonics Engineering Group, Santander, Spain
- Valdecilla Health Research Institute (IDIVAL), Santander, Spain
- Bioengineering, Biomaterials and Nanomedicine Research Network (CIBER-BBN), Madrid, Spain
| | - Daniel S Elson
- Imperial College London, Hamlyn Centre for Robotic Surgery, Department of Surgery and Cancer, London, United Kingdom
| |
Collapse
|
2
|
Bonaventura J, Morara K, Carlson R, Comrie C, Twer A, Hutchinson E, Sawyer TW. Evaluating backscattering polarized light imaging microstructural mapping capabilities through neural tissue and analogous phantom imaging. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:052914. [PMID: 38077501 PMCID: PMC10704260 DOI: 10.1117/1.jbo.29.5.052914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Revised: 10/01/2023] [Accepted: 11/06/2023] [Indexed: 12/18/2023]
Abstract
Significance Knowledge of fiber microstructure and orientation in the brain is critical for many applications. Polarized light imaging (PLI) has been shown to have potential for better understanding neural fiber microstructure and directionality due to the anisotropy in myelin sheaths surrounding nerve fibers of the brain. Continuing to advance backscattering based PLI systems could provide a valuable avenue for in vivo neural imaging. Aim To assess the potential of backscattering PLI systems, the ability to resolve crossing fibers, and the sensitivity to fiber inclination and curvature are considered across different imaging wavelengths. Approach Investigation of these areas of relative uncertainty is undergone through imaging potential phantoms alongside analogous regions of interest in fixed ferret brain samples with a five-wavelength backscattering Mueller matrix polarimeter. Results Promising phantoms are discovered for which the retardance, diattenuation and depolarization mappings are derived from the Mueller matrix and studied to assess the sensitivity of this polarimeter configuration to fiber orientations and tissue structures. Conclusions Rich avenues for future study include further classifying this polarimeter's sensitivity to fiber inclination and fiber direction to accurately produce microstructural maps of neural tissue.
Collapse
Affiliation(s)
- Justina Bonaventura
- University of Arizona, Wyant College of Optical Sciences, Tucson, Arizona, United States
| | - Kellys Morara
- University of Arizona, Department of Biomedical Engineering, Tucson, Arizona, United States
| | - Rhea Carlson
- University of Arizona, Department of Biomedical Engineering, Tucson, Arizona, United States
| | - Courtney Comrie
- University of Arizona, Department of Biomedical Engineering, Tucson, Arizona, United States
| | - AnneLeigh Twer
- University of Arizona, Department of Molecular and Cellular Biology, Tucson, Arizona, United States
| | - Elizabeth Hutchinson
- University of Arizona, Department of Biomedical Engineering, Tucson, Arizona, United States
| | - Travis W. Sawyer
- University of Arizona, Wyant College of Optical Sciences, Tucson, Arizona, United States
- University of Arizona, Department of Biomedical Engineering, Tucson, Arizona, United States
| |
Collapse
|
3
|
Felger L, Rodríguez-Núñez O, Gros R, Maragkou T, McKinley R, Moriconi S, Murek M, Zubak I, Novikova T, Pierangelo A, Schucht P. Robustness of the wide-field imaging Mueller polarimetry for brain tissue differentiation and white matter fiber tract identification in a surgery-like environment: an ex vivo study. BIOMEDICAL OPTICS EXPRESS 2023; 14:2400-2415. [PMID: 37206128 PMCID: PMC10191649 DOI: 10.1364/boe.486438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 03/30/2023] [Accepted: 04/01/2023] [Indexed: 05/21/2023]
Abstract
During neurooncological surgery, the visual differentiation of healthy and diseased tissue is often challenging. Wide-field imaging Muller polarimetry (IMP) is a promising technique for tissue discrimination and in-plane brain fiber tracking in an interventional setup. However, the intraoperative implementation of IMP requires realizing imaging in the presence of remanent blood, and complex surface topography resulting from the use of an ultrasonic cavitation device. We report on the impact of both factors on the quality of polarimetric images of the surgical resection cavities reproduced in fresh animal cadaveric brains. The robustness of IMP is observed under adverse experimental conditions, suggesting a feasible translation of IMP for in vivo neurosurgical applications.
Collapse
Affiliation(s)
- Leonard Felger
- Department of Neurosurgery, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland
| | - Omar Rodríguez-Núñez
- Department of Neurosurgery, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland
| | - Romain Gros
- Institute of Tissue Medicine and Pathology, University of Bern, 3010 Bern, Switzerland
| | - Theoni Maragkou
- Institute of Tissue Medicine and Pathology, University of Bern, 3010 Bern, Switzerland
| | - Richard McKinley
- SCAN, University Institute of Diagnostic and Interventional Radiology, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland
| | - Stefano Moriconi
- SCAN, University Institute of Diagnostic and Interventional Radiology, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland
| | - Michael Murek
- Department of Neurosurgery, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland
| | - Irena Zubak
- Department of Neurosurgery, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland
| | - Tatiana Novikova
- LPICM, CNRS, Ecole polytechnique, IP Paris, 91128 Palaiseau, France
| | | | - Philippe Schucht
- Department of Neurosurgery, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland
| |
Collapse
|
4
|
Automatic pseudo-coloring approaches to improve visual perception and contrast in polarimetric images of biological tissues. Sci Rep 2022; 12:18479. [PMID: 36323771 PMCID: PMC9630374 DOI: 10.1038/s41598-022-23330-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Accepted: 10/29/2022] [Indexed: 11/06/2022] Open
Abstract
Imaging polarimetry methods have proved their suitability to enhance the image contrast between tissues and structures in organic samples, or even to reveal structures hidden in regular intensity images. These methods are nowadays used in a wide range of biological applications, as for the early diagnosis of different pathologies. To include the discriminatory potential of different polarimetric observables in a single image, a suitable strategy reported in literature consists in associating different observables to different color channels, giving rise to pseudo-colored images helping the visualization of different tissues in samples. However, previous reported polarimetric based pseudo-colored images of tissues are mostly based on simple linear combinations of polarimetric observables whose weights are set ad-hoc, and thus, far from optimal approaches. In this framework, we propose the implementation of two pseudo-colored methods. One is based on the Euclidean distances of actual values of pixels and an average value taken over a given region of interest in the considered image. The second method is based on the likelihood for each pixel to belong to a given class. Such classes being defined on the basis of a statistical model that describes the statistical distribution of values of the pixels in the considered image. The methods are experimentally validated on four different biological samples, two of animal origin and two of vegetal origin. Results provide the potential of the methods to be applied in biomedical and botanical applications.
Collapse
|
5
|
Meglinski I, Novikova T, Dholakia K. Polarization and Orbital Angular Momentum of Light in Biomedical Applications: feature issue introduction. BIOMEDICAL OPTICS EXPRESS 2021; 12:6255-6258. [PMID: 34745733 PMCID: PMC8548002 DOI: 10.1364/boe.442828] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Indexed: 05/25/2023]
Abstract
In the last decade, consistent and successful innovations have been achieved in the field of lasers and optics, collectively known as 'photonics', founding new applications in biomedicine, including clinical biopsy. Non-invasive photonics-based diagnostic modalities are rapidly expanding, and with their exponential improvement, there is a great potential to develop practical instrumentation for automatic detection and identification of different types and/or sub-types of diseases at a very early stage. While using conventional light for the studies of different properties of objects in materials science, astrophysics and biomedicine already has a long history, the interaction of polarized light and optical angular momentum with turbid tissue-like scattering media has not yet been ultimately explored. Since recently this research area became a hot topic. This feature issue is a first attempt to summarize the recognitions achieved in this emerging research field of polarized light and optical angular momentum for practical biomedical applications during the last years.
Collapse
Affiliation(s)
- Igor Meglinski
- College of Engineering and Physical Science, Aston University, Birmingham, B4 7ET, United Kingdom
- Institute of Clinical Medicine N.V. Sklifosovsky, I.M. Sechenov First Moscow State Medical University, Moscow, Russia
- Optoelectronics and Measurement Techniques, ITEE, University of Oulu, Oulu, Finland
| | - Tatiana Novikova
- LPICM, CNRS, Ecole Polytechnique, Institut Polytechnique de Paris, Palaiseau, France
- Department of Biomedical Engineering, College of Engineering and Computing, Florida International University, Miami, FL 33174, USA
| | - Kishan Dholakia
- SUPA, School of Physics & Astronomy, University of St. Andrews, St. Andrews, KY16 9SS, United Kingdom
- Department of Physics, College of Science, Yonsei University, Seoul 03722, Republic of Korea
| |
Collapse
|
6
|
Rodríguez-Núñez O, Schucht P, Hewer E, Novikova T, Pierangelo A. Polarimetric visualization of healthy brain fiber tracts under adverse conditions: ex vivo studies. BIOMEDICAL OPTICS EXPRESS 2021; 12:6674-6685. [PMID: 34745764 PMCID: PMC8548022 DOI: 10.1364/boe.439754] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 09/22/2021] [Accepted: 09/22/2021] [Indexed: 05/09/2023]
Abstract
We suggest using the wide-field imaging Mueller polarimetry to contrast optically anisotropic fiber tracts of healthy brain white matter for the detection of brain tumor borders during neurosurgery. Our prior studies demonstrate that this polarimetric imaging modality detects correctly the in-plane orientation of brain white matter fiber tracts of a flat formalin-fixed thick brain specimen in reflection geometry [IEEE Trans. Med. Imaging39, 4376 (2020)10.1109/TMI.2020.3018439]. Here we present the results of ex vivo polarimetric studies of large cross-sections of fresh calf brain in reflection geometry with a special focus on the impact of the adverse measurement conditions (e.g. complex surface topography, presence of blood, etc.) on the quality of polarimetric images and the detection performance of white matter fiber tracts and their in-plane orientation.
Collapse
Affiliation(s)
| | - Philippe Schucht
- Department of Neurosurgery, Inselspital, Bern University Hospital, University of Bern, 3010, Bern, Switzerland
| | - Ekkehard Hewer
- Lausanne University Hospital and University of Lausanne, 1011 Lausanne, Switzerland
| | - Tatiana Novikova
- LPICM, CNRS, Ecole polytechnique, IP Paris, Palaiseau, 91128, France
| | - Angelo Pierangelo
- LPICM, CNRS, Ecole polytechnique, IP Paris, Palaiseau, 91128, France
| |
Collapse
|