1
|
Williamson S, Daniel-Watanabe L, Finnemann J, Powell C, Teed A, Allen M, Paulus M, Khalsa SS, Fletcher PC. The Hybrid Excess and Decay (HED) model: an automated approach to characterising changes in the photoplethysmography pulse waveform. Wellcome Open Res 2022. [DOI: 10.12688/wellcomeopenres.17855.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Photoplethysmography offers a widely used, convenient and non-invasive approach to monitoring basic indices of cardiovascular function, such as heart rate and blood oxygenation. Systematic analysis of the shape of the waveform generated by photoplethysmography might be useful to extract estimates of several physiological and psychological factors influencing the waveform. Here, we developed a robust and automated method for such a systematic analysis across individuals and across different physiological and psychological contexts. We describe a psychophysiologically-relevant model, the Hybrid Excess and Decay (HED) model, which characterises pulse wave morphology in terms of three underlying pressure waves and a decay function. We present the theoretical and practical basis for the model and demonstrate its performance when applied to a pharmacological dataset of 105 participants receiving intravenous administrations of the sympathomimetic drug isoproterenol (isoprenaline). We show that these parameters capture photoplethysmography data with a high degree of precision and, moreover, are sensitive to experimentally-induced changes in interoceptive arousal within individuals. We conclude by discussing the possible value in using the HED model as a complement to standard measures of photoplethysmography signals.
Collapse
|
2
|
Moscato S, Palmerini L, Palumbo P, Chiari L. Quality Assessment and Morphological Analysis of Photoplethysmography in Daily Life. Front Digit Health 2022; 4:912353. [PMID: 35873348 PMCID: PMC9300860 DOI: 10.3389/fdgth.2022.912353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2022] [Accepted: 06/08/2022] [Indexed: 11/13/2022] Open
Abstract
The photoplethysmographic (PPG) signal has been applied in various research fields, with promising results for its future clinical application. However, there are several sources of variability that, if not adequately controlled, can hamper its application in pervasive monitoring contexts. This study assessed and characterized the impact of several sources of variability, such as physical activity, age, sex, and health state on PPG signal quality and PPG waveform parameters (Rise Time, Pulse Amplitude, Pulse Time, Reflection Index, Delta T, and DiastolicAmplitude). We analyzed 31 24 h recordings by as many participants (19 healthy subjects and 12 oncological patients) with a wristband wearable device, selecting a set of PPG pulses labeled with three different quality levels. We implemented a Multinomial Logistic Regression (MLR) model to evaluate the impact of the aforementioned factors on PPG signal quality. We then extracted six parameters only on higher-quality PPG pulses and evaluated the influence of physical activity, age, sex, and health state on these parameters with Generalized Linear Mixed Effects Models (GLMM). We found that physical activity has a detrimental effect on PPG signal quality quality (94% of pulses with good quality when the subject is at rest vs. 9% during intense activity), and that health state affects the percentage of available PPG pulses of the best quality (at rest, 44% for healthy subjects vs. 13% for oncological patients). Most of the extracted parameters are influenced by physical activity and health state, while age significantly impacts two parameters related to arterial stiffness. These results can help expand the awareness that accurate, reliable information extracted from PPG signals can be reached by tackling and modeling different sources of inaccuracy.
Collapse
Affiliation(s)
- Serena Moscato
- Department of Electrical, Electronic, and Information Engineering “Guglielmo Marconi” – DEI, University of Bologna, Bologna, Italy
- *Correspondence: Serena Moscato
| | - Luca Palmerini
- Department of Electrical, Electronic, and Information Engineering “Guglielmo Marconi” – DEI, University of Bologna, Bologna, Italy
- Health Sciences and Technologies-Interdepartmental Center for Industrial Research (CIRI-SDV), University of Bologna, Bologna, Italy
| | - Pierpaolo Palumbo
- Department of Electrical, Electronic, and Information Engineering “Guglielmo Marconi” – DEI, University of Bologna, Bologna, Italy
| | - Lorenzo Chiari
- Department of Electrical, Electronic, and Information Engineering “Guglielmo Marconi” – DEI, University of Bologna, Bologna, Italy
- Health Sciences and Technologies-Interdepartmental Center for Industrial Research (CIRI-SDV), University of Bologna, Bologna, Italy
| |
Collapse
|
3
|
Haque CA, Hossain S, Kwon TH, Kim KD. Noninvasive In Vivo Estimation of Blood-Glucose Concentration by Monte Carlo Simulation. SENSORS 2021; 21:s21144918. [PMID: 34300657 PMCID: PMC8309922 DOI: 10.3390/s21144918] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 07/12/2021] [Accepted: 07/14/2021] [Indexed: 11/16/2022]
Abstract
Continuous monitoring of blood-glucose concentrations is essential for both diabetic and nondiabetic patients to plan a healthy lifestyle. Noninvasive in vivo blood-glucose measurements help reduce the pain of piercing human fingertips to collect blood. To facilitate noninvasive measurements, this work proposes a Monte Carlo photon simulation-based model to estimate blood-glucose concentration via photoplethysmography (PPG) on the fingertip. A heterogeneous finger model was exposed to light at 660 nm and 940 nm in the reflectance mode of PPG via Monte Carlo photon propagation. The bio-optical properties of the finger model were also deduced to design the photon simulation model for the finger layers. The intensities of the detected photons after simulation with the model were used to estimate the blood-glucose concentrations using a supervised machine-learning model, XGBoost. The XGBoost model was trained with synthetic data obtained from the Monte Carlo simulations and tested with both synthetic and real data (n = 35). For testing with synthetic data, the Pearson correlation coefficient (Pearson’s r) of the model was found to be 0.91, and the coefficient of determination (R2) was found to be 0.83. On the other hand, for tests with real data, the Pearson’s r of the model was 0.85, and R2 was 0.68. Error grid analysis and Bland–Altman analysis were also performed to confirm the accuracy. The results presented herein provide the necessary steps for noninvasive in vivo blood-glucose concentration estimation.
Collapse
|
4
|
Probing penile hemodynamics by using photoplethysmography as objective indicators for male erection quality and sexual function. Sci Rep 2021; 11:12019. [PMID: 34103629 PMCID: PMC8187730 DOI: 10.1038/s41598-021-91582-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Accepted: 05/27/2021] [Indexed: 11/09/2022] Open
Abstract
Erectile dysfunction (ED) is mostly due to the lack of blood flow into the penis. In the past 20 years, near-infrared spectroscopy (NIRS) was used in measuring the concentrations and temporal dynamics of different hemoglobin types. However, the dynamics of the light absorption (photoplethysmography; PPG) have not been applied to survey penile hemodynamics and erection quality. This paper compared the use of photoplethysmography (PPG) to study vascular ED with standard penile Doppler ultrasonography. Men diagnosed with vascular ED for at least 6 months and nominated for penile ultrasonography were included. PPG signals were collected during the ultrasound examination. All beat-to-beat PPG waveforms were aligned with the peak and averaged to one representative template waveform for feature analysis, including amplitude differences (APD) index, reflection time index (RTI), augmentation index (AI), and perfusion index (PI). An inverse correlation was found between end-erection amplitude and both erection hardness score (EHS) and resistive index (RI). APD index and EHS as well as the international index of erectile function-5 (IIEF) and RI were positively correlated. RTI and AI were inversely correlated to IIEF and RI. PI was positively correlated to RI. PPG may therefore be useful as a noninvasive, convenient, technique for sexual function evaluation.
Collapse
|
5
|
Yamazaki H, Fujimoto K. A new noninvasive method for measurement of dynamic lung compliance from fluctuations on photoplethysmography in respiration. J Appl Physiol (1985) 2021; 130:215-225. [PMID: 33119473 DOI: 10.1152/japplphysiol.00295.2020] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Lung compliance is important in interstitial lung disease (ILD). However, the measurement requires placement of an esophageal pressure probe and is therefore not done in routine clinic practice. This study was performed to develop and verify a new noninvasive method for estimation of dynamic lung compliance (Cdyn) with a photoplethysmograph (PPG) of pulse wave represented as the changes of absorbance of green LED for hemoglobin and to examine its usefulness. A system for measuring Cdyn in combination with changes in estimated pleural pressure (Ppl) from the fluctuations on PPG with respiration and lung volume measured simultaneously by spirometry was developed and verified to show correspondence with the estimated Ppl and the esophageal pressure (Pes), estimated Cdyn, and Cdyn measured with an esophageal balloon. Furthermore, the estimated percentage of predicted Cdyn (%Cdyn) was compared among healthy subjects (HS) (n = 33) and patients with chronic obstructive pulmonary disease (COPD) (n = 31) and ILD (n = 30). Both estimated Ppl and Cdyn were significantly correlated with Pes (r = 0.89) and measured Cdyn (r = 0.63), respectively. The estimated %Cdyn in ILD showed significantly lower values than those in HS and COPD. The estimated %Cdyn was significantly related to percentage of predicted vital capacity (VC) (r = 0.57, P < 0.01) and percentage of predicted diffusion capacity of carbon monoxide (DlCO) (r = 0.50, P < 0.01) in patients with ILD. These findings suggested that the newly developed noninvasive and convenient method for Cdyn estimation using a combination of PPG and spirometry may be useful for the assessment of lung fibrosis in ILD.NEW & NOTEWORTHY Our newly developed method for measuring dynamic lung compliance (Cdyn) in combination with changes in estimated intrathoracic pressure from fluctuations on photoplethysmography with respiration and lung volume measured simultaneously by spirometry showed good linear regression between the estimated Cdyn and the Cdyn measured with an esophageal balloon, and the estimated percentage of predicted Cdyn (%Cdyn) showed significantly lower values in patients with interstitial lung disease (ILD) than in healthy subjects and chronic obstructive pulmonary disease (COPD) patients and significant correlations with vital capacity and lung diffusion capacity.
Collapse
Affiliation(s)
- Haruna Yamazaki
- Department of Biomedical Laboratory Sciences, Graduate School of Medicine, Shinshu University, Matsumoto, Nagano, Japan
| | - Keisaku Fujimoto
- Department of Clinical Laboratory Sciences, Shinshu University School of Health Sciences, Matsumoto, Nagano, Japan
| |
Collapse
|
6
|
Allen J, O'Sullivan J, Stansby G, Murray A. Age-related changes in pulse risetime measured by multi-site photoplethysmography. Physiol Meas 2020; 41:074001. [PMID: 32784270 DOI: 10.1088/1361-6579/ab9b67] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE It is accepted that changes in the peripheral pulse waveform characteristics occur with ageing. Pulse risetime is one important feature which has clinical value. However, it is unclear how it varies across the full age spectrum from child to senior and for different peripheral measurement sites. The objectives of this study were to determine the association between age and pulse risetime characteristics over an 8-decade age range at the ears, fingers, and toes, and to consider effects arising from differences in systolic blood pressure (SBP), height and heart rate. APPROACH Multi-site photoplethysmography (MPPG) pulse waveforms were recorded non-invasively from the right and left ears, fingers, and toes of 304 normal healthy human subjects (range 6-87 years; 156 male and 148 female). SBP, height, and heart rate were also measured. Multi-site PPG pulse risetimes, and their site differences, were determined. MAIN RESULTS Univariate regression analysis showed positive correlations with risetime for age (ears, fingers and toes: + 0.8, + 1.9, and + 1.1 ms/year, respectively), SBP (+0.5, + 1.3, and + 0.9 ms/mmHg) and height (+0.5, + 1.2, and + 1.0 ms/cm), but with a clear inverse association with heart rate (-1.8, - 2.5, and - 1.6 ms min) (P < 0.0001). No significant differences between male and female subjects were found for pulse risetime. SIGNIFICANCE Normative multi-site PPG risetime characteristics have been defined in over 300 subjects and are shown to increase with age linearly up to the 8th decade. In contrast, we have shown that heart rate has a clear inverse relationship with risetime for all measurement sites.
Collapse
Affiliation(s)
- John Allen
- Centre for Intelligent Healthcare, Coventry University, Coventry, CV1 5FB, United Kingdom. Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, NE2 4HH, United Kingdom
| | | | | | | |
Collapse
|
7
|
Abdul Manap A, Md Izah SS, Mohamed K. Molecular Dynamics Study of Poly(dimethylsiloxane) Nanostructure Distortion in a Soft Lithography Demolding Process. ACS OMEGA 2019; 4:20257-20264. [PMID: 31815228 PMCID: PMC6893944 DOI: 10.1021/acsomega.9b02547] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Accepted: 11/13/2019] [Indexed: 06/10/2023]
Abstract
This study aims at investigating the distortion of poly(dimethylsiloxane) (PDMS) nanostructures in a soft lithography demolding process using molecular dynamics simulation. Experimental results show that after peeling, PDMS nanopillars became 10-60% longer in height than the mold size. Molecular dynamics simulations have been employed to plot the stress-strain curve of the nanopillars when subjected to uniaxial stress. Three force fields (COMPASS, CVFF, and PCFF) were used for modeling. The demolding process in soft lithography and nanoimprint lithography causes significant deformation in replication. The experimental results show clear signs of elongation after demolding. Molecular dynamics simulations are employed to study the stress-strain relationship of the PDMS nanopillars. The results from the simulation show that a PDMS nanopillar at temperature T = 300 K under tensile stress shows characteristics of flexible plastic under tensile stress and has a lower Young's modulus, ultimate tensile stress, and Poisson's ratio.
Collapse
Affiliation(s)
- Abdul
Haadi Abdul Manap
- Nanofabrication
and Functional Research Group, School of Mechanical Engineering, Engineering
Campus, Universiti Sains Malaysia, 14300 Nibong Tebal, Penang, Malaysia
| | - Siti Suhaila Md Izah
- Nanofabrication
and Functional Research Group, School of Mechanical Engineering, Engineering
Campus, Universiti Sains Malaysia, 14300 Nibong Tebal, Penang, Malaysia
| | - Khairudin Mohamed
- Nanofabrication
and Functional Research Group, School of Mechanical Engineering, Engineering
Campus, Universiti Sains Malaysia, 14300 Nibong Tebal, Penang, Malaysia
- NOR Lab,
School of Physics, Universiti Sains Malaysia, 11900 George, Penang, Malaysia
| |
Collapse
|
8
|
Photoplethysmography-Based Continuous Systolic Blood Pressure Estimation Method for Low Processing Power Wearable Devices. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9112236] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Regardless of age, it is always important to detect deviations in long-term blood pressure from normal levels. Continuous monitoring of blood pressure throughout the day is even more important for elderly people with cardiovascular diseases or a high risk of stroke. The traditional cuff-based method for blood pressure measurements is not suitable for continuous real-time applications and is very uncomfortable. To address this problem, continuous blood pressure measurement methods based on photoplethysmogram (PPG) have been developed. However, these methods use specialized high-performance hardware and sensors, which are not available for common users. This paper proposes the continuous systolic blood pressure (SBP) estimation method based on PPG pulse wave steepness for low processing power wearable devices and evaluates its suitability using the commercially available CMS50FW Pulse Oximeter. The SBP estimation is done based on the PPG pulse wave steepness (rising edge angle) because it is highly correlated with systolic blood pressure. The SBP estimation based on this single feature allows us to significantly reduce the amount of data processed and avoid errors, due to PPG pulse wave amplitude changes resulting from physiological or external factors. The experimental evaluation shows that the proposed SBP estimation method allows the use of off-the-shelf wearable PPG measurement devices with a low sampling rate (up to 60 Hz) and low resolution (up to 8-bit) for precise SBP measurements (mean difference MD = −0.043 and standard deviation SD = 6.79). In contrast, the known methods for continuous SBP estimation are based on equipment with a much higher sampling rate and better resolution characteristics.
Collapse
|
9
|
Lam J, Chan G, Morgan WH, Hazelton M, Betz-Stablein B, Cringle SJ, Yu DY. Structural characteristics of the optic nerve head influencing human retinal venous pulsations. Exp Eye Res 2016; 145:341-346. [PMID: 26892807 DOI: 10.1016/j.exer.2016.02.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2015] [Revised: 01/01/2016] [Accepted: 02/10/2016] [Indexed: 10/22/2022]
|
10
|
Minimally invasive or noninvasive cardiac output measurement: an update. J Anesth 2016; 30:461-80. [DOI: 10.1007/s00540-016-2154-9] [Citation(s) in RCA: 49] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2015] [Accepted: 02/17/2016] [Indexed: 12/15/2022]
|