1
|
Fang L, Huang F. Measurement precision bounds on aberrated single molecule emission patterns. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.11.30.569462. [PMID: 38076960 PMCID: PMC10705439 DOI: 10.1101/2023.11.30.569462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/17/2023]
Abstract
Single-Molecule Localization Microscopy (SMLM) has revolutionized the study of biological phenomena by providing exquisite nanoscale spatial resolution. However, optical aberrations induced by sample and system imperfections distort the single molecule emission patterns (i.e. PSFs), leading to reduced precision and resolution of SMLM, particularly in three-dimensional (3D) applications. While various methods, both analytical and instrumental, have been employed to mitigate these aberrations, a comprehensive analysis of how different types of commonly encountered aberrations affect single molecule experiments and their image formation remains missing. In this study, we addressed this gap by conducting a quantitative study of the theoretical precision limit for position and wavefront distortion measurements in the presence of aberrations. Leveraging Fisher information and Cramér-Rao lower bound (CRLB), we quantitively analyzed and compared the effects of different aberration types, including index mismatch aberrations, on localization precision in both biplane and astigmatism 3D modalities as well as 2D SMLM imaging. Furthermore, we studied the achievable wavefront estimation precision from aberrated single molecule emission patterns, a pivot step for successful adaptive optics in SMLM through thick specimens. This analysis lays a quantitative foundation for the development and application of SMLM in whole-cells, tissues and with large field of view, providing in-depth insights into the behavior of different aberration types in single molecule imaging and thus generating theoretical guidelines for developing highly efficient aberration correction strategies and enhancing the precision and reliability of 3D SMLM.
Collapse
Affiliation(s)
- Li Fang
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA
| | - Fang Huang
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA
- Purdue Institute for Integrative Neuroscience, Purdue University, West Lafayette, IN, USA
- Purdue Institute of Inflammation, Immunology and Infectious Disease, Purdue University, West Lafayette, IN, USA
| |
Collapse
|
2
|
He C, Zhan Z, Li C, Sun X, Liu Y, Kuang C, Liu X. Effects of optical aberrations on localization of MINFLUX super-resolution microscopy. OPTICS EXPRESS 2022; 30:46849-46860. [PMID: 36558626 DOI: 10.1364/oe.475425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Accepted: 11/22/2022] [Indexed: 06/17/2023]
Abstract
A novel super-resolution imaging technique based on the minimum photon flux (MINFLUX), can achieve nanometer-scale localization precision and sub-5-nm imaging. However, aberrations can affect the localization performance and degrade the quality of reconstructed images. In this study, we analyze the effects of different low-order aberrations on the MINFLUX system through both theoretical limits and Monte Carlo methods. We report that 1) defocus and spherical aberration have little effect on 2D localization performance, whereas astigmatism and coma have significant negative effects; 2) system aberrations that can be measured in advance cause changes primarily in the magnitude and angular uniformity of localization precision, whereas sample-induced aberrations that cannot be a priori introduce large biases and reduce localization accuracy.
Collapse
|
3
|
Chowdhury R, Sau A, Chao J, Sharma A, Musser SM. Tuning axial and lateral localization precision in 3D super-resolution microscopy with variable astigmatism. OPTICS LETTERS 2022; 47:5727-5730. [PMID: 37219314 PMCID: PMC10332797 DOI: 10.1364/ol.466213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Accepted: 10/06/2022] [Indexed: 05/24/2023]
Abstract
Astigmatism imaging is a three-dimensional (3D) single molecule fluorescence microscopy approach that yields super-resolved spatial information on a rapid time scale from a single image. It is ideally suited for resolving structures on a sub-micrometer scale and temporal behavior in the millisecond regime. While traditional astigmatism imaging utilizes a cylindrical lens, adaptive optics enables the astigmatism to be tuned for the experiment. We demonstrate here how the precisions in x, y, and z are inter-linked and vary with the astigmatism, z-position, and photon level. This experimentally driven and verified approach provides a guide for astigmatism selection in biological imaging strategies.
Collapse
Affiliation(s)
| | | | | | - Ankith Sharma
- Department of Cell Biology and Genetics, Texas A&M University, School of Medicine, 1114 TAMU, College Station, TX 77843, USA
| | - Siegfried M. Musser
- Department of Cell Biology and Genetics, Texas A&M University, School of Medicine, 1114 TAMU, College Station, TX 77843, USA
| |
Collapse
|
4
|
Wang J, Zhang Y. Adaptive optics in super-resolution microscopy. BIOPHYSICS REPORTS 2021; 7:267-279. [PMID: 37287764 PMCID: PMC10233472 DOI: 10.52601/bpr.2021.210015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Accepted: 06/23/2021] [Indexed: 06/09/2023] Open
Abstract
Fluorescence microscopy has become a routine tool in biology for interrogating life activities with minimal perturbation. While the resolution of fluorescence microscopy is in theory governed only by the diffraction of light, the resolution obtainable in practice is also constrained by the presence of optical aberrations. The past two decades have witnessed the advent of super-resolution microscopy that overcomes the diffraction barrier, enabling numerous biological investigations at the nanoscale. Adaptive optics, a technique borrowed from astronomical imaging, has been applied to correct for optical aberrations in essentially every microscopy modality, especially in super-resolution microscopy in the last decade, to restore optimal image quality and resolution. In this review, we briefly introduce the fundamental concepts of adaptive optics and the operating principles of the major super-resolution imaging techniques. We highlight some recent implementations and advances in adaptive optics for active and dynamic aberration correction in super-resolution microscopy.
Collapse
Affiliation(s)
- Jingyu Wang
- Department of Engineering Science, University of Oxford, Oxford, OX1 3PJ, UK
| | - Yongdeng Zhang
- School of Life Sciences, Westlake University, Hangzhou 310024, China
- Westlake Laboratory of Life Sciences and Biomedicine, Hangzhou 310024, China
| |
Collapse
|
5
|
Siemons M, Cloin BMC, Salas DM, Nijenhuis W, Katrukha EA, Kapitein LC. Comparing strategies for deep astigmatism-based single-molecule localization microscopy. BIOMEDICAL OPTICS EXPRESS 2020; 11:735-751. [PMID: 32133221 PMCID: PMC7041481 DOI: 10.1364/boe.382023] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2019] [Revised: 12/12/2019] [Accepted: 12/13/2019] [Indexed: 05/22/2023]
Abstract
Single-molecule localization microscopy (SMLM) enables fluorescent microscopy with nanometric resolution. While localizing molecules close to the coverslip is relatively straightforward using high numerical aperture (NA) oil immersion (OI) objectives, optical aberrations impede SMLM deeper in watery samples. Adaptive optics (AO) with a deformable mirror (DM) can be used to correct such aberrations and to induce precise levels of astigmatism to encode the z-position of molecules. Alternatively, the use of water immersion (WI) objectives might be sufficient to limit the most dominant aberrations. Here we compare SMLM at various depths using either WI or OI with or without AO. In addition, we compare the performance of a cylindrical lens and a DM for astigmatism-based z-encoding. We find that OI combined with adaptive optics improves localization precision beyond the performance of WI-based imaging and enables deep (>10 µm) 3D localization.
Collapse
|
6
|
Tehrani KF, Zhang Y, Shen P, Kner P. Adaptive optics stochastic optical reconstruction microscopy (AO-STORM) by particle swarm optimization. BIOMEDICAL OPTICS EXPRESS 2017; 8:5087-5097. [PMID: 29188105 PMCID: PMC5695955 DOI: 10.1364/boe.8.005087] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2017] [Revised: 10/10/2017] [Accepted: 10/10/2017] [Indexed: 05/12/2023]
Abstract
Stochastic optical reconstruction microscopy (STORM) can achieve resolutions of better than 20nm imaging single fluorescently labeled cells. However, when optical aberrations induced by larger biological samples degrade the point spread function (PSF), the localization accuracy and number of localizations are both reduced, destroying the resolution of STORM. Adaptive optics (AO) can be used to correct the wavefront, restoring the high resolution of STORM. A challenge for AO-STORM microscopy is the development of robust optimization algorithms which can efficiently correct the wavefront from stochastic raw STORM images. Here we present the implementation of a particle swarm optimization (PSO) approach with a Fourier metric for real-time correction of wavefront aberrations during STORM acquisition. We apply our approach to imaging boutons 100 μm deep inside the central nervous system (CNS) of Drosophila melanogaster larvae achieving a resolution of 146 nm.
Collapse
Affiliation(s)
- Kayvan F. Tehrani
- College of Engineering, University of Georgia, Athens, GA 30602, USA
- Currently with the Regenerative Bioscience Center, University of Georgia, Athens, GA 30602, USA
| | - Yiwen Zhang
- Department of Cellular Biology, University of Georgia, Athens, GA 30602, USA
| | - Ping Shen
- Department of Cellular Biology, University of Georgia, Athens, GA 30602, USA
| | - Peter Kner
- College of Engineering, University of Georgia, Athens, GA 30602, USA
| |
Collapse
|
7
|
von Diezmann A, Shechtman Y, Moerner WE. Three-Dimensional Localization of Single Molecules for Super-Resolution Imaging and Single-Particle Tracking. Chem Rev 2017; 117:7244-7275. [PMID: 28151646 PMCID: PMC5471132 DOI: 10.1021/acs.chemrev.6b00629] [Citation(s) in RCA: 264] [Impact Index Per Article: 37.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Single-molecule super-resolution fluorescence microscopy and single-particle tracking are two imaging modalities that illuminate the properties of cells and materials on spatial scales down to tens of nanometers or with dynamical information about nanoscale particle motion in the millisecond range, respectively. These methods generally use wide-field microscopes and two-dimensional camera detectors to localize molecules to much higher precision than the diffraction limit. Given the limited total photons available from each single-molecule label, both modalities require careful mathematical analysis and image processing. Much more information can be obtained about the system under study by extending to three-dimensional (3D) single-molecule localization: without this capability, visualization of structures or motions extending in the axial direction can easily be missed or confused, compromising scientific understanding. A variety of methods for obtaining both 3D super-resolution images and 3D tracking information have been devised, each with their own strengths and weaknesses. These include imaging of multiple focal planes, point-spread-function engineering, and interferometric detection. These methods may be compared based on their ability to provide accurate and precise position information on single-molecule emitters with limited photons. To successfully apply and further develop these methods, it is essential to consider many practical concerns, including the effects of optical aberrations, field dependence in the imaging system, fluorophore labeling density, and registration between different color channels. Selected examples of 3D super-resolution imaging and tracking are described for illustration from a variety of biological contexts and with a variety of methods, demonstrating the power of 3D localization for understanding complex systems.
Collapse
Affiliation(s)
| | - Yoav Shechtman
- Department of Chemistry, Stanford University, Stanford, CA 94305
| | - W. E. Moerner
- Department of Chemistry, Stanford University, Stanford, CA 94305
| |
Collapse
|
8
|
Lambert TJ, Waters JC. Navigating challenges in the application of superresolution microscopy. J Cell Biol 2017; 216:53-63. [PMID: 27920217 PMCID: PMC5223610 DOI: 10.1083/jcb.201610011] [Citation(s) in RCA: 66] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2016] [Revised: 11/15/2016] [Accepted: 11/18/2016] [Indexed: 11/22/2022] Open
Abstract
In 2014, the Nobel Prize in Chemistry was awarded to three scientists who have made groundbreaking contributions to the field of superresolution (SR) microscopy (SRM). The first commercial SR microscope came to market a decade earlier, and many other commercial options have followed. As commercialization has lowered the barrier to using SRM and the awarding of the Nobel Prize has drawn attention to these methods, biologists have begun adopting SRM to address a wide range of questions in many types of specimens. There is no shortage of reviews on the fundamental principles of SRM and the remarkable achievements made with these methods. We approach SRM from another direction: we focus on the current practical limitations and compromises that must be made when designing an SRM experiment. We provide information and resources to help biologists navigate through common pitfalls in SRM specimen preparation and optimization of image acquisition as well as errors and artifacts that may compromise the reproducibility of SRM data.
Collapse
Affiliation(s)
- Talley J Lambert
- Department of Cell Biology, Harvard Medical School, Boston, MA 02115
| | - Jennifer C Waters
- Department of Cell Biology, Harvard Medical School, Boston, MA 02115
| |
Collapse
|