Nouizi F, Kwong TC, Turong B, Nikkhah D, Sampathkumaran U, Gulsen G. Fast ICCD-based temperature modulated fluorescence tomography. APPLIED OPTICS 2023; 62:7420-7430. [PMID: 37855510 DOI: 10.1364/ao.499281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Accepted: 09/06/2023] [Indexed: 10/20/2023]
Abstract
Fluorescence tomography (FT) has become a powerful preclinical imaging modality with a great potential for several clinical applications. Although it has superior sensitivity and utilizes low-cost instrumentation, the highly scattering nature of bio-tissue makes FT in thick samples challenging, resulting in poor resolution and low quantitative accuracy. To overcome the limitations of FT, we previously introduced a novel method, termed temperature modulated fluorescence tomography (TMFT), which is based on two key elements: (1) temperature-sensitive fluorescent agents (ThermoDots) and (2) high-intensity focused ultrasound (HIFU). The fluorescence emission of ThermoDots increases up to hundredfold with only several degree temperature elevation. The exceptional and reversible response of these ThermoDots enables their modulation, which effectively allows their localization using the HIFU. Their localization is then used as functional a priori during the FT image reconstruction process to resolve their distribution with higher spatial resolution. The last version of the TMFT system was based on a cooled CCD camera utilizing a step-and-shoot mode, which necessitated long total imaging time only for a small selected region of interest (ROI). In this paper, we present the latest version of our TMFT technology, which uses a much faster continuous HIFU scanning mode based on an intensified CCD (ICCD) camera. This new, to the best of our knowledge, version can capture the whole field-of-view (FOV) of 50×30m m 2 at once and reduces the total imaging time down to 30 min, while preserving the same high resolution (∼1.3m m) and superior quantitative accuracy (<7% error) as the previous versions. Therefore, this new method is an important step toward utilization of TMFT for preclinical imaging.
Collapse
|
2
|
Nouizi F, Erkol H, Nikkhah D, Kwong TC, Gulsen G. Development of a preclinical CCD-based temperature modulated fluorescence tomography platform. BIOMEDICAL OPTICS EXPRESS 2022; 13:5740-5752. [PMID: 36733748 PMCID: PMC9872903 DOI: 10.1364/boe.470723] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 09/25/2022] [Accepted: 09/26/2022] [Indexed: 05/11/2023]
Abstract
In preclinical research, fluorescence molecular tomography (FMT) is the most sensitive imaging modality to interrogate whole-body and provide 3D distribution of fluorescent contract agents. Despite its superior sensitivity, its mediocre spatial-resolution has been the main barrier to its clinical translation. This limitation is mainly due to the high scattering of optical photons in biological tissue together with the limited boundary measurements that lead to an undetermined and ill-posed inverse problem. To overcome the limitations of FMT, we previously introduced a novel method termed, Temperature Modulated Fluorescence Tomography (TMFT). TMFT utilizes thermos-sensitive fluorescent agents (ThermoDots) as a key component and localizes them with high-intensity focused ultrasound (HIFU). Scanning the focused HIFU beam having a diameter Ø = 1.3 mm across the tissue while monitoring the variation in the measured fluorescence signals reveals the position of the ThermoDots with high spatial accuracy. We have formerly built a prototype TMFT system that uses optical fibers for detection. In this paper, we present an upgraded version using a CCD camera-based detection that enables non-contact imaging. In this version, the animal under investigation is placed on an ultrasound transparent membrane, which eliminates the need for its immersion in optical matching fluids that were required by the fiber-based system. This CCD-based system will pave the way for convenient and wide-spread use of TMFT in preclinical research. Its performance validation on phantom studies demonstrates that high spatial-resolution (∼1.3 mm) and quantitative accuracy in recovered fluorophore concentration (<3% error) can be achieved.
Collapse
Affiliation(s)
- Farouk Nouizi
- Tu and Yuen Center for Functional Onco-Imaging, Department of Radiological Sciences, University of California Irvine, CA 92697, USA
- Chao Family Comprehensive Cancer Center, University of California Irvine, CA 92697, USA
| | - Hakan Erkol
- Department of Physics, Bogazici University, Bebek, 34342, Istanbul, Turkey
| | - Deniz Nikkhah
- Tu and Yuen Center for Functional Onco-Imaging, Department of Radiological Sciences, University of California Irvine, CA 92697, USA
| | - Tiffany C. Kwong
- Tu and Yuen Center for Functional Onco-Imaging, Department of Radiological Sciences, University of California Irvine, CA 92697, USA
| | - Gultekin Gulsen
- Tu and Yuen Center for Functional Onco-Imaging, Department of Radiological Sciences, University of California Irvine, CA 92697, USA
- Chao Family Comprehensive Cancer Center, University of California Irvine, CA 92697, USA
| |
Collapse
|
3
|
Nouizi F, Brooks J, Zuro DM, Hui SK, Gulsen G. Development of a theranostic preclinical fluorescence molecular tomography/cone beam CT-guided irradiator platform. BIOMEDICAL OPTICS EXPRESS 2022; 13:6100-6112. [PMID: 36733750 PMCID: PMC9872876 DOI: 10.1364/boe.469559] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 09/21/2022] [Accepted: 09/22/2022] [Indexed: 05/11/2023]
Abstract
Image-guided small animal radiation research platforms allow more precise radiation treatment. Commercially available small animal X-ray irradiators are often equipped with a CT/cone-beam CT (CBCT) component for target guidance. Besides having poor soft-tissue contrast, CBCT unfortunately cannot provide molecular information due to its low sensitivity. Hence, there are extensive efforts to incorporate a molecular imaging component besides CBCT on these radiation therapy platforms. As an extension of these efforts, here we present a theranostic fluorescence tomography/CBCT-guided irradiator platform that provides both anatomical and molecular guidance, which can overcome the limitations of stand-alone CBCT. The performance of our hybrid system is validated using both tissue-like phantoms and mice ex vivo. Both studies show that fluorescence tomography can provide much more accurate quantitative results when CBCT-derived structural information is used to constrain the inverse problem. The error in the recovered fluorescence absorbance reduces nearly 10-fold for all cases, from approximately 60% down to 6%. This is very significant since high quantitative accuracy in molecular information is crucial to the correct assessment of the changes in tumor microenvironment related to radiation therapy.
Collapse
Affiliation(s)
- Farouk Nouizi
- Tu and Yuen Center for Functional Onco-Imaging, Department of Radiological Sciences, University of California Irvine, CA 92697, USA
- Chao Family Comprehensive Cancer Center, University of California Irvine, CA 92697, USA
| | - Jamison Brooks
- Department of Radiation Oncology, Beckman Research Institute, City of Hope National Medical Center, Duarte, CA 91010, USA
| | - Darren M. Zuro
- Department of Radiation Oncology, Beckman Research Institute, City of Hope National Medical Center, Duarte, CA 91010, USA
| | - Susanta K. Hui
- Department of Radiation Oncology, Beckman Research Institute, City of Hope National Medical Center, Duarte, CA 91010, USA
| | - Gultekin Gulsen
- Tu and Yuen Center for Functional Onco-Imaging, Department of Radiological Sciences, University of California Irvine, CA 92697, USA
- Chao Family Comprehensive Cancer Center, University of California Irvine, CA 92697, USA
| |
Collapse
|
4
|
Zhang Y, Zhang L, Yin G, Ma W, Li J, Zhou Z, Gao F. In Vivo Pharmacokinetics Assessment of Indocyanine Green-Loaded Nanoparticles in Tumor Tissue with a Dynamic Diffuse Fluorescence Tomography System. Mol Imaging Biol 2019; 21:1044-1053. [PMID: 30850969 DOI: 10.1007/s11307-019-01340-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
PURPOSE The purpose of this study was to show a systematic strategy for assessing the pharmacokinetics of indocyanine green (ICG)-loaded nanoparticles in the tumor tissue based on a dynamic diffuse fluorescence tomography (DFT) system. PROCEDURES Twelve-seven-week-old male Balb/c nude mice bearing HepG2/ADR hepatocellular carcinoma were randomly divided into four groups (n = 3 per group). Four hundred microliters of three types of ICG-loaded nanoparticles (content of ICG: 50 μg/ml) and free ICG (50 μg/ml) was intravenously injected into the mice in each group, respectively. Afterwards, the real-time tomographic images on the spatial level were acquired at 2-11 min, 30 min, 1, 2, 3, 4, 6, 8, 10, 12, and 24 h post-injection, and pharmacokinetic rates were derived for semi-quantitative assessment of the pharmacokinetics of nanoparticles at the tumor site using our proposed pharmacokinetic analysis method. RESULTS The results obtained from our proposed dynamic DFT experiment demonstrated the distribution of different ICG formulations on the spatial level and enabled the semi-quantitative analysis of the pharmacokinetics of nanoparticles in the tumor tissue. CONCLUSIONS The obtained pharmacokinetic rates effectively reflected the metabolic processes of nanoparticles in the tumor tissue, which proves to be beneficial for the development of tumor diagnosis and therapy.
Collapse
Affiliation(s)
- Yanqi Zhang
- School of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, 300072, China
| | - Limin Zhang
- School of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, 300072, China. .,Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin, 300072, China.
| | - Guoyan Yin
- School of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, 300072, China
| | - Wenjuan Ma
- Cancer Institute and Hospital, Tianjin Medical University, Tianjin, 300060, China
| | - Jiao Li
- School of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, 300072, China.,Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin, 300072, China
| | - Zhongxing Zhou
- School of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, 300072, China.,Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin, 300072, China
| | - Feng Gao
- School of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, 300072, China. .,Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin, 300072, China.
| |
Collapse
|
5
|
Zhang Y, Zhang L, Yin G, Ma W, Gao F. Assessing indocyanine green pharmacokinetics in mouse liver with a dynamic diffuse fluorescence tomography system. JOURNAL OF BIOPHOTONICS 2018; 11:e201800041. [PMID: 29797547 DOI: 10.1002/jbio.201800041] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Accepted: 05/22/2018] [Indexed: 06/08/2023]
Abstract
Fluorescence pharmacokinetic rates in tissues can provide additional specific and quantitative physiological and pathological information for evaluating organ function. This modality requires a highly sensitive diffuse fluorescence tomography (DFT) working in dynamic way to finally extract the pharmacokinetic rates from the measured pharmacokinetics-associated temporally varying boundary intensity, normally with the support of a priori anatomy. This paper is devoted to study pharmacokinetics of indocyanine green (ICG) in mouse liver based on synergistic dynamic-DFT and X-ray computer tomography (XCT): A highly sensitive dynamic DFT system of CT-scanning mode working with parallel 4 photomultiplier-tube photon-counting channels generates informative and instantaneous sampling datasets; An XCT system provides priori information of the target localization for improvement of the reconstruction quality; An analysis procedure extracts the pharmacokinetic rates from the reconstructed ICG concentration-time curves, using the Gauss-Newton scheme for fitting to a 2-compartment model. The uptake and excretion rates of ICG which were obtained in livers of 10 healthy mice in the in vivo experiments can be used to quantitatively evaluate liver function. The results can validate the effectiveness of both the imaging measurements system and pharmacokinetic analysis method.
Collapse
Affiliation(s)
- Yanqi Zhang
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, China
| | - Limin Zhang
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, China
- Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin, China
| | - Guoyan Yin
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, China
| | - Wenjuan Ma
- Cancer Institute and Hospital, Tianjin Medical University, Tianjin, China
| | - Feng Gao
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, China
- Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin, China
| |
Collapse
|
6
|
Zhang B, Yin W, Liu H, Cao X, Wang H. Bioluminescence tomography with structural information estimated via statistical mouse atlas registration. BIOMEDICAL OPTICS EXPRESS 2018; 9:3544-3558. [PMID: 30338139 PMCID: PMC6191626 DOI: 10.1364/boe.9.003544] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Revised: 06/27/2018] [Accepted: 07/02/2018] [Indexed: 05/10/2023]
Abstract
Due to an ill-posed and underestimated characteristic of bioluminescence tomography (BLT) reconstruction, a priori anatomical information obtained from computed tomography (CT) or magnetic resonance imaging (MRI), is usually incorporated to improve the reconstruction accuracy. The organs need to be segmented, which is time-consuming and challenging, especially for the low-contrast CT images. In this paper, we present a BLT reconstruction method based on a statistical mouse atlas to improve the efficiency of heterogeneous model generation and the accuracy of target localization. The low-contrast CT image of the mouse was first registered to the statistical mouse atlas model with the constraints of mouse surface and high-contrast organs (bone and lung). Then the other organs, such as the liver and kidney, were determined automatically through the statistical mouse atlas model. The estimated organs were then discretized into tetrahedral meshes for BLT reconstruction. The linearized Bregman method was used to solve the sparse inverse problem of BLT by minimizing the regularization function (L1 norm plus L2 norm with smooth factor). Both numerical simulations and in vivo experiments were conducted, and the results demonstrate that even though the localization of the estimated organs may not be exactly accurate, the proposed method is feasible to reconstruct the bioluminescent source effectively and accurately with the estimated organs. This method would greatly benefit the bioluminescent light source localization for hybrid BLT/CT systems.
Collapse
Affiliation(s)
- Bin Zhang
- School of Biomedical Engineering, Dalian University of Technology, Dalian, Liaoning 116024, China
| | - Wanzhou Yin
- School of Biomedical Engineering, Dalian University of Technology, Dalian, Liaoning 116024, China
| | - Hao Liu
- School of Biomedical Engineering, Dalian University of Technology, Dalian, Liaoning 116024, China
| | - Xu Cao
- Engineering Research Center of Molecular and Neuro Imaging of the Ministry of Education & School of Life Science and Technology, Xidian University, Xi'an, Shaanxi 710071, China
| | - Hongkai Wang
- School of Biomedical Engineering, Dalian University of Technology, Dalian, Liaoning 116024, China
| |
Collapse
|
7
|
Wang Y, Li J, Lu T, Zhang L, Zhou Z, Zhao H, Gao F. Combined diffuse optical tomography and photoacoustic tomography for enhanced functional imaging of small animals: a methodological study on phantoms. APPLIED OPTICS 2017; 56:303-311. [PMID: 28085867 DOI: 10.1364/ao.56.000303] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Hybrid imaging methods combining diffuse optical tomography (DOT) and other anatomical or nonoptical functional modalities have been widely investigated to improve imaging performance degraded by the strong optical scattering of biological tissues, through constraining the reconstruction process by prior structures. However, these modalities with different contrast mechanisms may be ineffective in revealing early-staged lesions with high optical contrast but no morphological changes. Photoacoustic tomography (PAT) is particularly useful for visualizing light-absorbing structures embedded in soft tissues with high spatial resolution. Although it is still challenging for PAT to quantitatively disclose the absorption distribution, the modality does provide reliable and specific a priori information differentiating light-absorbing structures of soft tissues and might be more appropriate to guide DOT in lesion diagnosis, as compared with other anatomical or nonoptical functional modalities. In this study, a PAT-guided DOT approach is introduced with both soft- and hard-prior regularizations. The methodology is experimentally validated on small-animal-sized phantoms using a computed-tomography-analogous (CT-analogous) PAT/DOT dual-modality system, focusing on future whole-body applications. The results show that the proposed scheme is capable of effectively improving the quantitative accuracy and spatial resolution of DOT reconstruction.
Collapse
|