Brunner E, Kunze L, Drexler W, Pollreisz A, Pircher M. Image Quality in Adaptive Optics Optical Coherence Tomography of Diabetic Patients. Diagnostics (Basel) 2025; 15:429. [PMID: 40002580 PMCID: PMC11854792 DOI: 10.3390/diagnostics15040429] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2024] [Revised: 01/17/2025] [Accepted: 01/30/2025] [Indexed: 02/27/2025] Open
Abstract
Background/Objectives: An assessment of the retinal image quality in adaptive optics optical coherence tomography (AO-OCT) is challenging. Many factors influence AO-OCT imaging performance, leading to greatly varying imaging results, even in the same subject. The aim of this study is to introduce quantitative means for an assessment of AO-OCT image quality and to compare these with parameters retrieved from the pyramid wavefront sensor of the system. Methods: We used a spectral domain AO-OCT instrument to repetitively image six patients suffering from diabetic retinopathy over a time span of one year. The data evaluation consists of two volume acquisitions with a focus on the photoreceptor layer, each at five different retinal locations per visit; 7-8 visits per patient are included in this data analysis, resulting in a total of ~420 volumes. Results: A large variability in AO-OCT image quality is observed between subjects and between visits of the same subject. On average, the image quality does not depend on the measurement location. The data show a moderate correlation between the axial position of the volume recording and image quality. The correlation between pupil size and AO-OCT image quality is not linear. A weak correlation is found between the signal-to-noise ratio of the wavefront sensor image and the image quality. Conclusions: The introduced AO-OCT image quality metric gives useful insights into the performance of such a system. A longitudinal assessment of this metric, together with wavefront sensor data, is essential to identify factors influencing image quality and, in the next step, to optimize the performance of AO-OCT systems.
Collapse
Affiliation(s)
- Elisabeth Brunner
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Wien, Austria; (E.B.); (W.D.)
| | - Laura Kunze
- Department of Ophthalmology and Optometry, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Wien, Austria; (L.K.); (A.P.)
| | - Wolfgang Drexler
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Wien, Austria; (E.B.); (W.D.)
| | - Andreas Pollreisz
- Department of Ophthalmology and Optometry, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Wien, Austria; (L.K.); (A.P.)
| | - Michael Pircher
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Wien, Austria; (E.B.); (W.D.)
| |
Collapse
|
2
|
Vasilescu MA, Macovei ML. The Perspective of Using Optical Coherence Tomography in Ophthalmology: Present and Future Applications. Diagnostics (Basel) 2025; 15:402. [PMID: 40002553 PMCID: PMC11854452 DOI: 10.3390/diagnostics15040402] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2024] [Revised: 01/17/2025] [Accepted: 02/05/2025] [Indexed: 02/27/2025] Open
Abstract
Optical coherence tomography (OCT) imaging plays a major role in the field of diagnosing, monitoring, and treating ophthalmological diseases. Since its introduction in the early 1990s, OCT technology has continued to advance both in the direction of acquisition quality and technique. In this manuscript, we concentrate on actual and future applications of OCT in the ophthalmology field, reviewing multiple types of OCT techniques and systems, such as visible-light OCT, adaptative optics OCT, intraoperative OCT, wide-field OCT, and more. All of them allow better monitoring of ocular diseases, earlier and broader diagnosis, and a more suitable treatment. Furthermore, overviewing all these technologies could play a pivotal role in research, leading to an advance in understanding the pathophysiology of targeted diseases. Finally, the aim of the present review was to evaluate the technical advances in OCT and their actual and potential clinical applications.
Collapse
Affiliation(s)
- Mario A. Vasilescu
- Department of Ophthalmology, “Dr. Carol Davila” Central Military Emergency University Hospital, 010825 Bucharest, Romania;
| | - Mioara L. Macovei
- Department of Ophthalmology, “Dr. Carol Davila” Central Military Emergency University Hospital, 010825 Bucharest, Romania;
- Ophthalmology Department, “Carol Davila” University of Medicine and Pharmacy, 050474 Bucharest, Romania
| |
Collapse
|
3
|
Ma G, McCloud M, Tian Y, Narawane A, Shi H, Trout R, McNabb RP, Kuo AN, Draelos M. Robotics and optical coherence tomography: current works and future perspectives [Invited]. BIOMEDICAL OPTICS EXPRESS 2025; 16:578-602. [PMID: 39958851 PMCID: PMC11828438 DOI: 10.1364/boe.547943] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/14/2024] [Revised: 12/29/2024] [Accepted: 01/01/2025] [Indexed: 02/18/2025]
Abstract
Optical coherence tomography (OCT) is an interferometric technique for micron-level imaging in biological and non-biological contexts. As a non-invasive, non-ionizing, and video-rate imaging modality, OCT is widely used in biomedical and clinical applications, especially ophthalmology, where it functions in many roles, including tissue mapping, disease diagnosis, and intrasurgical visualization. In recent years, the rapid growth of medical robotics has led to new applications for OCT, primarily for 3D free-space scanning, volumetric perception, and novel optical designs for specialized medical applications. This review paper surveys these recent developments at the intersection of OCT and robotics and organizes them by degree of integration and application, with a focus on biomedical and clinical topics. We conclude with perspectives on how these recent innovations may lead to further advances in imaging and medical technology.
Collapse
Affiliation(s)
- Guangshen Ma
- Department of Robotics, University of Michigan Ann Arbor, MI 48105, USA
| | - Morgan McCloud
- Department of Biomedical Engineering, Duke University, Durham, NC 27705, USA
| | - Yuan Tian
- Department of Biomedical Engineering, Duke University, Durham, NC 27705, USA
| | - Amit Narawane
- Department of Biomedical Engineering, Duke University, Durham, NC 27705, USA
| | - Harvey Shi
- Department of Biomedical Engineering, Duke University, Durham, NC 27705, USA
| | - Robert Trout
- Department of Biomedical Engineering, Duke University, Durham, NC 27705, USA
| | - Ryan P McNabb
- Department of Ophthalmology, Duke University Medical Center, Durham, NC 27705, USA
| | - Anthony N Kuo
- Department of Biomedical Engineering, Duke University, Durham, NC 27705, USA
- Department of Ophthalmology, Duke University Medical Center, Durham, NC 27705, USA
| | - Mark Draelos
- Department of Robotics, University of Michigan Ann Arbor, MI 48105, USA
- Department of Ophthalmology and Visual Sciences, University of Michigan Medical School, Ann Arbor, MI 48105, USA
| |
Collapse
|
4
|
Limcharoen B, Wanichwecharungruang S, Banlunara W, Darvin ME. Seeing through the skin: Optical methods for visualizing transdermal drug delivery with microneedles. Adv Drug Deliv Rev 2025; 217:115478. [PMID: 39603387 DOI: 10.1016/j.addr.2024.115478] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2024] [Revised: 11/08/2024] [Accepted: 11/22/2024] [Indexed: 11/29/2024]
Abstract
Optical methods play a pivotal role in advancing transdermal drug delivery research, particularly with the emergence of microneedle technology. This review presents a comprehensive analysis of optical methods used in studying transdermal drug delivery facilitated by microneedle technology. Beginning with an introduction to microneedle technology and skin anatomy and optical properties, the review explores the integration of optical methods for enhanced visualization. Optical imaging offers key advantages including real-time drug distribution visualization, non-invasive skin response monitoring, and quantitative drug penetration analysis. A spectrum of optical imaging modalities ranging from conventional dermoscopy and stereomicroscopy to advance techniques as fluorescence microscopy, laser scanning microscopy, in vivo imaging system, two-photon microscopy, fluorescence lifetime imaging microscopy, optical coherence tomography, Raman microspectroscopy, laser speckle contrast imaging, and photoacoustic microscopy is discussed. Challenges such as resolution and depth penetration limitations are addressed alongside potential breakthroughs and future directions in optical techniques development. The review underscores the importance of bridging the gap between preclinical and clinical studies, explores opportunities for integrating optical imaging and chemical sensing methods with drug delivery systems, and highlight the importance of non-invasive "optical biopsy" as a valuable alternative to conventional histology. Overall, this review provides insight into the role of optical methods in understanding transdermal drug delivery mechanisms with microneedles.
Collapse
Affiliation(s)
- Benchaphorn Limcharoen
- Department of Anatomy, Faculty of Veterinary Science, Chulalongkorn University, Bangkok 10330, Thailand; Center of Excellence in Advanced Materials and Biointerfaces, Chulalongkorn University, Pathumwan, Bangkok 10330, Thailand.
| | - Supason Wanichwecharungruang
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Pathumwan, Bangkok 10330, Thailand; Center of Excellence in Advanced Materials and Biointerfaces, Chulalongkorn University, Pathumwan, Bangkok 10330, Thailand
| | - Wijit Banlunara
- Department of Pathology, Faculty of Veterinary Science, Chulalongkorn University, Pathumwan, Bangkok 10330, Thailand; Center of Excellence in Advanced Materials and Biointerfaces, Chulalongkorn University, Pathumwan, Bangkok 10330, Thailand
| | - Maxim E Darvin
- Fraunhofer Institute for Photonic Microsystems IPMS, Dresden 01109, Germany.
| |
Collapse
|
5
|
Li X, Guo X, Wang X, Jiang L, Li M, Dai X, Hao Q, Zhao J, Huang Y, Sun L. Wearable optical coherence tomography angiography probe with extended depth of field. JOURNAL OF BIOMEDICAL OPTICS 2025; 30:016003. [PMID: 39845726 PMCID: PMC11752921 DOI: 10.1117/1.jbo.30.1.016003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/06/2024] [Revised: 12/23/2024] [Accepted: 12/27/2024] [Indexed: 01/24/2025]
Abstract
Significance Optical coherence tomography (OCT) is widely utilized to investigate brain activities and disorders in anesthetized or restrained rodents. However, anesthesia can alter several physiological parameters, leading to findings that might not fully represent the true physiological state. To advance the understanding of brain function in awake and freely moving animals, the development of wearable OCT probes is crucial. Aim We aim to address the challenge of insufficient depth of field (DOF) in wearable OCT probes for brain imaging in freely moving mice, ensuring high lateral resolution while capturing brain vasculature across varying heights. Approach We integrated diffractive optical elements (DOEs) capable of generating beams with an extended DOF into a wearable OCT probe. This design effectively overcomes the traditional trade-off between lateral resolution and DOF, enabling the capture of detailed angiographic images in a dynamic and uncontrolled environment. Results The enhanced wearable OCT probe achieved a lateral resolution superior to 8 μ m within a 450 μ m axial range. This setup allowed for high-resolution optical coherence tomography angiography (OCTA) imaging with extended DOF, making it suitable for studying brain vasculature in freely moving mice. Conclusions The incorporation of DOEs into the wearable OCT probe represents a significant advancement in wearable biomedical imaging. This technology facilitates the acquisition of high-resolution angiographic images with an extended DOF, thus enhancing the ability to study brain function in awake and naturally behaving animals.
Collapse
Affiliation(s)
- Xiaochen Li
- Tsinghua University, State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Beijing, China
| | - Xiangyu Guo
- Tsinghua University, State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Beijing, China
| | - Xinyue Wang
- Tsinghua University, School of Biomedical Engineering, Beijing, China
| | - Lingqi Jiang
- Tsinghua University, State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Beijing, China
| | - Mingxin Li
- Tsinghua University, State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Beijing, China
| | - Xiaochuan Dai
- Tsinghua University, School of Biomedical Engineering, Beijing, China
| | - Qun Hao
- Beijing Institute of Technology, School of Optics and Photonics, Beijing, China
| | - Jingjing Zhao
- Huazhong University of Science and Technology, Institute of Medical Equipment Science and Engineering, Wuhan, China
| | - Yong Huang
- Beijing Institute of Technology, School of Optics and Photonics, Beijing, China
| | - Liqun Sun
- Tsinghua University, State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Beijing, China
| |
Collapse
|
6
|
Son K, Lee W, Kim WT, Jeon M, Kim J, Jin MU, Kim SY, Lee KB. A feasibility study on the use of an intraoral optical coherence tomography system for scanning the subgingival finish line for the fabrication of zirconia crowns: An evaluation of the marginal and internal fit. J Dent 2024; 151:105386. [PMID: 39366541 DOI: 10.1016/j.jdent.2024.105386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2024] [Revised: 09/25/2024] [Accepted: 10/01/2024] [Indexed: 10/06/2024] Open
Abstract
OBJECTIVES This study aimed to evaluate the marginal and internal fit of zirconia crowns were fabricated using scan data from an intraoral optical coherence tomography (OCT) scanner and an intraoral scanner (IOS) for scanning the subgingival finish line. METHODS An extracted maxillary left central incisor was prepared for a zirconia crown. The prepared tooth was placed in artificial gingiva, created using silicone with a refractive index similar to that of the tooth, ensuring a subgingival depth of 0.50 to 0.70 mm from the labial finish line. Scanning data were obtained from four types of models as follows. (1) CAD reference model (CRM) excluding the gingiva and scanned using a laboratory scanner. (2) IOS group excluding the gingiva (IOS only, IOSO group). (3) IOS group with scanned attached artificial (IOS with gingiva, IOSG group). (4) OCT post-processed data of the subgingival finish line and IOSG data (OCT group). Zirconia crowns were fabricated based on these data, and their marginal and internal fit were evaluated using the silicone replica technique. Statistical analyses were conducted using one-way and two-way ANOVA (α = 0.05). RESULTS The OCT group exhibited a significantly smaller marginal gap than the IOSG group (P < 0.05). The marginal fit of the OCT group did not significantly differ from that of the CRM group (P > 0.05). The IOSG group exhibited a significantly larger chamfer gap, while both the IOSG and OCT groups had significantly larger axial gaps. Furthermore, the OCT group showed a significantly larger incisal gap (P < 0.05). CONCLUSIONS An intraoral OCT system can enhance the fabrication accuracy of zirconia crowns by achieving superior marginal fit for crowns with subgingival finish lines. CLINICAL SIGNIFICANCE The use of an IOS for subgingival finish lines without gingival displacement cords may result in a suboptimal marginal fit. However, integrating OCT technology can effectively address this issue, leading to improved clinical outcomes.
Collapse
Affiliation(s)
- KeunBaDa Son
- Advanced Dental Device Development Institute (A3DI), School of Dentistry, Kyungpook National University, 2177 Dalgubeol-daero, Jung-gu, Daegu, 41940, Republic of Korea.
| | - Weonjoon Lee
- Huvitz Co., Ltd., 38 Burim-ro 170beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, Republic of Korea.
| | - Wook-Tae Kim
- Department of Dental Technology & Science, Shinhan University, 95 Hoam-ro, Uijeongbu-si, Gyeonggi-do, Republic of Korea.
| | - Mansik Jeon
- School of Electronics Engineering, College of IT Engineering, Kyungpook National University, 80, Daehak-ro, Buk-gu, Daegu, 41566, Republic of Korea.
| | - Jeehyun Kim
- School of Electronics Engineering, College of IT Engineering, Kyungpook National University, 80, Daehak-ro, Buk-gu, Daegu, 41566, Republic of Korea.
| | - Myoung-Uk Jin
- Department of Conservative Dentistry, School of Dentistry, Kyungpook National University, 2177 Dalgubeol-daero, Jung-gu, Daegu, 41940, Republic of Korea.
| | - So-Yeun Kim
- Department of Prosthodontics, School of Dentistry, Kyungpook National University, 2177 Dalgubeol-daero, Jung-gu, Daegu, 41940, Republic of Korea.
| | - Kyu-Bok Lee
- Department of Prosthodontics, School of Dentistry, Kyungpook National University, 2177 Dalgubeol-daero, Jung-gu, Daegu, 41940, Republic of Korea.
| |
Collapse
|
7
|
Liu Y, Crowell JA, Kurokawa K, Bernucci MT, Ji Q, Lassoued A, Jung HW, Keller MJ, Marte ME, Miller DT. Ultrafast adaptive optics for imaging the living human eye. Nat Commun 2024; 15:10409. [PMID: 39613735 DOI: 10.1038/s41467-024-54687-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Accepted: 11/19/2024] [Indexed: 12/01/2024] Open
Abstract
Adaptive optics (AO) is a powerful method for correcting dynamic aberrations in numerous applications. When applied to the eye, it enables cellular-resolution retinal imaging and enhanced visual performance and stimulation. Most ophthalmic AO systems correct dynamic aberrations up to 1-2 Hz, the commonly-known cutoff frequency for correcting ocular aberrations. However, this frequency may be grossly underestimated for more clinically relevant scenarios where the medical impact of AO will be greatest. Unfortunately, little is known about the aberration dynamics in these scenarios. A major bottleneck has been the lack of sufficiently fast AO systems to measure and correct them. We develop an ultrafast ophthalmic AO system that increases AO bandwidth by ~30× and improves aberration power rejection magnitude by 500×. We demonstrate that this much faster ophthalmic AO is possible without sacrificing other system performances. We find that the discontinuous-exposure AO-control scheme runs 32% slower yet achieves 53% larger AO bandwidth than the commonly used continuous-exposure scheme. Using the ultrafast system, we characterize ocular aberration dynamics in six clinically-relevant scenarios and find their power spectra to be 10-100× larger than normal. We show that ultrafast AO substantially improves aberration correction and retinal imaging performance in these scenarios compared with conventional AO.
Collapse
Affiliation(s)
- Yan Liu
- School of Optometry, Indiana University, Bloomington, IN, USA.
| | - James A Crowell
- School of Optometry, Indiana University, Bloomington, IN, USA
| | - Kazuhiro Kurokawa
- School of Optometry, Indiana University, Bloomington, IN, USA
- Discoveries in Sight Research Laboratories, Devers Eye Institute, Legacy Research Institute, Legacy Health, Portland, OR, USA
| | | | - Qiuzhi Ji
- School of Optometry, Indiana University, Bloomington, IN, USA
| | - Ayoub Lassoued
- School of Optometry, Indiana University, Bloomington, IN, USA
- Centre Hospitalier National d'Ophtalmologie des Quinze-Vingts Centre d'investigation clinique, Paris, Île-de-France, France; Institut de la vision, Paris, Île-de-France, Paris, France
| | - Hae Won Jung
- School of Optometry, Indiana University, Bloomington, IN, USA
- University of Houston, Houston, TX, USA
| | | | - Mary E Marte
- School of Optometry, Indiana University, Bloomington, IN, USA
- Richard L. Roudebush VAMC, Indianapolis, IN, USA
| | - Donald T Miller
- School of Optometry, Indiana University, Bloomington, IN, USA.
| |
Collapse
|
8
|
Mecê P, Gocho K, Harmening W, Rossi E, Young L. Editorial: Advances in optical imaging for ophthalmology: new developments, clinical applications and perspectives. FRONTIERS IN OPHTHALMOLOGY 2024; 4:1496015. [PMID: 39479555 PMCID: PMC11521964 DOI: 10.3389/fopht.2024.1496015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/13/2024] [Accepted: 09/19/2024] [Indexed: 11/02/2024]
Affiliation(s)
- Pedro Mecê
- Institut Langevin, ESPCI Paris, CNRS, PSL University, Paris, France
| | - Kiyoko Gocho
- Centre d’Investigation Clinique, Quinze-Vingts National Ophthalmology Hospital, Paris, France
| | - Wolf Harmening
- Rheinische Friedrich-Wilhelms-Universität Bonn, University Eye Hospital, Bonn, Germany
| | - Ethan Rossi
- Department of Ophthalmology, University of Pittsburgh School of Medicine, Pittsburgh, PA, United States
| | - Laura Young
- Biosciences Institute, Newcastle University, Newcastle, United Kingdom
| |
Collapse
|
9
|
Brunner E, Kunze L, Laidlaw V, Jodlbauer D, Drexler W, Ramlau R, Pollreisz A, Pircher M. Improvements on speed, stability and field of view in adaptive optics OCT for anterior retinal imaging using a pyramid wavefront sensor. BIOMEDICAL OPTICS EXPRESS 2024; 15:6098-6116. [PMID: 39421790 PMCID: PMC11482182 DOI: 10.1364/boe.533451] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/20/2024] [Revised: 08/19/2024] [Accepted: 08/19/2024] [Indexed: 10/19/2024]
Abstract
We present improvements on the adaptive optics (AO) correction method using a pyramid wavefront sensor (P-WFS) and introduce a novel approach for closed-loop focus shifting in retinal imaging. The method's efficacy is validated through in vivo adaptive optics optical coherence tomography (AO-OCT) imaging in both, healthy individuals and patients with diabetic retinopathy. In both study groups, a stable focusing on the anterior retinal layers is achieved. We further report on an improvement in AO loop speed that can be used to expand the imaging area of AO-OCT in the slow scanning direction, largely independent of the eye's isoplanatic patch. Our representative AO-OCT data reveal microstructural details of the neurosensory retina such as vessel walls and microglia cells that are visualized in single volume data and over an extended field of view. The excellent performance of the P-WFS based AO-OCT imaging in patients suggests good clinical applicability of this technology.
Collapse
Affiliation(s)
- Elisabeth Brunner
- Center for Medical Physics and Biomedical
Engineering, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Wien, Austria
| | - Laura Kunze
- Department of Ophthalmology and Optometry, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Wien, Austria
| | - Victoria Laidlaw
- Johannes Kepler University Linz, Industrial Mathematics Institute, Altenbergerstraße 69, A-4040 Linz, Austria
| | - Daniel Jodlbauer
- Johann Radon Institute for Computational and Applied Mathematics, Altenbergerstraße 69, A-4040 Linz, Austria
| | - Wolfgang Drexler
- Center for Medical Physics and Biomedical
Engineering, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Wien, Austria
| | - Ronny Ramlau
- Johannes Kepler University Linz, Industrial Mathematics Institute, Altenbergerstraße 69, A-4040 Linz, Austria
| | - Andreas Pollreisz
- Department of Ophthalmology and Optometry, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Wien, Austria
| | - Michael Pircher
- Center for Medical Physics and Biomedical
Engineering, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Wien, Austria
| |
Collapse
|
10
|
Grad J, Hatamnejad A, Pattathil N, Golding J, Choudhry N. Photoreceptor Characteristics in Diabetic Retinopathy vs Controls Using Adaptive Optics Imaging: Systematic Review. JOURNAL OF VITREORETINAL DISEASES 2024:24741264241286682. [PMID: 39539836 PMCID: PMC11556365 DOI: 10.1177/24741264241286682] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2024]
Abstract
Purpose: To assess the differences in morphological photoreceptor outcomes measured using adaptive optics (AO)-assisted imaging between individuals with diabetes or prediabetes and healthy controls. Methods: A systematic search was conducted across MEDLINE, Embase, and Cochrane databases from January 2000 to June 2023. Studies that used AO-assisted imaging modalities to quantitatively compare photoreceptor outcomes in patients with diabetes or prediabetes with healthy controls were included. Results: Eleven studies consisting of 551 eyes were included. Most studies reported significant differences in photoreceptor outcomes between diabetic and healthy populations, particularly as diabetic retinopathy (DR) severity increased. Cone regularity was the most sensitive parameter for detecting significant differences between groups. AO imaging was less reliable in distinguishing individuals with diabetes without DR or with mild DR severity from controls. Conclusions: AO imaging showed promise in detecting significant differences associated with diabetes and DR, in particular with increasing disease severity. Further research is warranted to assess AO's utility as a diabetes and DR screening tool. Standardizing imaging protocols in future studies is recommended to allow for more direct quantitative comparisons. These findings highlight the current evidence on photoreceptor changes in patients with diabetes and the potential of AO in advancing diabetic eye care.
Collapse
Affiliation(s)
- Justin Grad
- Michael DeGroote School of Medicine, McMaster University, Hamilton, ON, Canada
| | - Amin Hatamnejad
- Michael DeGroote School of Medicine, McMaster University, Hamilton, ON, Canada
| | | | - John Golding
- Vitreous Retina Macula Specialists of Toronto, Etobicoke, ON, Canada
| | - Netan Choudhry
- Vitreous Retina Macula Specialists of Toronto, Etobicoke, ON, Canada
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, ON, Canada
- Cleveland Clinic Canada, Toronto, ON, Canada
- Retina Consultants of Texas, Blanton Eye Institute, Houston Methodist Hospital, Houston, TX, USA
| |
Collapse
|
11
|
Kreis J, Carroll J. Applications of Adaptive Optics Imaging for Studying Conditions Affecting the Fovea. Annu Rev Vis Sci 2024; 10:239-262. [PMID: 38635871 DOI: 10.1146/annurev-vision-102122-100022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/20/2024]
Abstract
The fovea is a highly specialized region of the central retina, defined by an absence of inner retinal layers and the accompanying vasculature, an increased density of cone photoreceptors, a near absence of rod photoreceptors, and unique private-line photoreceptor to midget ganglion cell circuitry. These anatomical specializations support high-acuity vision in humans. While direct study of foveal shape and size is routinely performed using optical coherence tomography, examination of the other anatomical specializations of the fovea has only recently become possible using an array of adaptive optics (AO)-based imaging tools. These devices correct for the eye's monochromatic aberrations and permit cellular-resolution imaging of the living retina. In this article, we review the application of AO-based imaging techniques to conditions affecting the fovea, with an emphasis on how imaging has advanced our understanding of pathophysiology.
Collapse
Affiliation(s)
- Joseph Kreis
- Department of Cell Biology, Neurobiology & Anatomy, Medical College of Wisconsin, Milwaukee, Wisconsin, USA; ,
| | - Joseph Carroll
- Joint Department of Biomedical Engineering, Marquette University and the Medical College of Wisconsin, Milwaukee, Wisconsin, USA
- Department of Ophthalmology & Visual Sciences, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
- Department of Cell Biology, Neurobiology & Anatomy, Medical College of Wisconsin, Milwaukee, Wisconsin, USA; ,
| |
Collapse
|
12
|
Rui Y, Zhang M, Lee DM, Snyder VC, Raghuraman R, Gofas-Salas E, Mecê P, Yadav S, Tiruveedhula P, Grieve K, Sahel JA, Errera MH, Rossi EA. Label-Free Imaging of Inflammation at the Level of Single Cells in the Living Human Eye. OPHTHALMOLOGY SCIENCE 2024; 4:100475. [PMID: 38881602 PMCID: PMC11179426 DOI: 10.1016/j.xops.2024.100475] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 12/22/2023] [Accepted: 01/16/2024] [Indexed: 06/18/2024]
Abstract
Purpose Putative microglia were recently detected using adaptive optics ophthalmoscopy in healthy eyes. Here we evaluate the use of nonconfocal adaptive optics scanning light ophthalmoscopy (AOSLO) for quantifying the morphology and motility of presumed microglia and other immune cells in eyes with retinal inflammation from uveitis and healthy eyes. Design Observational exploratory study. Participants Twelve participants were imaged, including 8 healthy participants and 4 posterior uveitis patients recruited from the clinic of 1 of the authors (M.H.E.). Methods The Pittsburgh AOSLO imaging system was used with a custom-designed 7-fiber optical fiber bundle for simultaneous confocal and nonconfocal multioffset detection. The inner retina was imaged at several locations at multiple timepoints in healthy participants and uveitis patients to generate time-lapse images. Main Outcome Measures Microglia and macrophages were manually segmented from nonconfocal AOSLO images, and their morphological characteristics quantified (including soma size, diameter, and circularity). Cell soma motion was quantified across time for periods of up to 30 minutes and their speeds were calculated by measuring their displacement over time. Results A spectrum of cell morphologies was detected in healthy eyes from circular amoeboid cells to elongated cells with visible processes, resembling activated and ramified microglia, respectively. Average soma diameter was 16.1 ± 0.9 μm. Cell movement was slow in healthy eyes (0.02 μm/sec on average), but macrophage-like cells moved rapidly in some uveitis patients (up to 3 μm/sec). In an eye with infectious uveitis, many macrophage-like cells were detected; during treatment their quantity and motility decreased as vision improved. Conclusions In vivo adaptive optics ophthalmoscopy offers promise as a potentially powerful tool for detecting and monitoring inflammation and response to treatment at a cellular level in the living eye. Financial Disclosures Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
Collapse
Affiliation(s)
- Yuhua Rui
- Department of Ophthalmology, University of Pittsburgh School of Medicine Pittsburgh, Pennsylvania
- Eye Center of Xiangya Hospital, Central South University Hunan Key Laboratory of Ophthalmology Changsha, Hunan, China
| | - Min Zhang
- Department of Ophthalmology, University of Pittsburgh School of Medicine Pittsburgh, Pennsylvania
| | - Daniel M.W. Lee
- Department of Bioengineering, University of Pittsburgh Swanson School of Engineering Pittsburgh, Pennsylvania
| | - Valerie C. Snyder
- Department of Ophthalmology, University of Pittsburgh School of Medicine Pittsburgh, Pennsylvania
| | - Rashmi Raghuraman
- Department of Ophthalmology, University of Pittsburgh School of Medicine Pittsburgh, Pennsylvania
| | - Elena Gofas-Salas
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, Paris, France
- CHNO des Quinze-Vingts, INSERM-DGOS CIC 1423, Paris, France
| | - Pedro Mecê
- Institut Langevin, ESPCI Paris, Université PSL, CNRS, Paris, France
| | - Sanya Yadav
- Department of Ophthalmology, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania
| | | | - Kate Grieve
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, Paris, France
- CHNO des Quinze-Vingts, INSERM-DGOS CIC 1423, Paris, France
| | - José-Alain Sahel
- Department of Ophthalmology, University of Pittsburgh School of Medicine Pittsburgh, Pennsylvania
| | - Marie-Hélène Errera
- Department of Ophthalmology, University of Pittsburgh School of Medicine Pittsburgh, Pennsylvania
| | - Ethan A. Rossi
- Department of Ophthalmology, University of Pittsburgh School of Medicine Pittsburgh, Pennsylvania
- Department of Bioengineering, University of Pittsburgh Swanson School of Engineering Pittsburgh, Pennsylvania
- McGowan Institute for Regenerative Medicine Pittsburgh, Pennsylvania
| |
Collapse
|
13
|
Abbasi N, Chen K, Wong A, Bizheva K. Computational approach for correcting defocus and suppressing speckle noise in line-field optical coherence tomography images. BIOMEDICAL OPTICS EXPRESS 2024; 15:5491-5504. [PMID: 39296416 PMCID: PMC11407272 DOI: 10.1364/boe.530569] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/20/2024] [Revised: 07/12/2024] [Accepted: 08/14/2024] [Indexed: 09/21/2024]
Abstract
The trade-off between transverse resolution and depth-of-focus (DOF) typical for optical coherence tomography (OCT) systems based on conventional optics, prevents "single-shot" acquisition of volumetric OCT images with sustained high transverse resolution over the entire imaging depth. Computational approaches for correcting defocus and higher order aberrations in OCT images developed in the past require highly stable phase data, which poses a significant technological challenge. Here, we present an alternative computational approach to sharpening OCT images and reducing speckle noise, based on intensity OCT data. The novel algorithm uses non-local priors to model correlated speckle noise within a maximum a posteriori framework to generate sharp and noise-free images. The performance of the algorithm was tested on images of plant tissue (cucumber) and in-vivo healthy human cornea, acquired with line-field spectral domain OCT (LF-SD-OCT) systems. The novel algorithm effectively suppressed speckle noise and sharpened or recovered morphological features in the OCT images for depths up to 13×DOF (depth-of-focus) relative to the focal plane.
Collapse
Affiliation(s)
- Nima Abbasi
- Department of Systems Design Engineering, University of Waterloo, Waterloo, Ontario, Canada
| | - Keyu Chen
- Department of Physics and Astronomy, University of Waterloo, Waterloo, Ontario, Canada
| | - Alexander Wong
- Department of Systems Design Engineering, University of Waterloo, Waterloo, Ontario, Canada
| | - Kostadinka Bizheva
- Department of Systems Design Engineering, University of Waterloo, Waterloo, Ontario, Canada
- Department of Physics and Astronomy, University of Waterloo, Waterloo, Ontario, Canada
- School of Optometry and Vision Sciences, University of Waterloo, Waterloo, Ontario, Canada
| |
Collapse
|
14
|
Zhang F, Kovalick K, Raghavendra A, Soltanian-Zadeh S, Farsiu S, Hammer DX, Liu Z. In vivo imaging of human retinal ganglion cells using optical coherence tomography without adaptive optics. BIOMEDICAL OPTICS EXPRESS 2024; 15:4675-4688. [PMID: 39346995 PMCID: PMC11427184 DOI: 10.1364/boe.533249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/18/2024] [Revised: 06/21/2024] [Accepted: 06/25/2024] [Indexed: 10/01/2024]
Abstract
Retinal ganglion cells play an important role in human vision, and their degeneration results in glaucoma and other neurodegenerative diseases. Imaging these cells in the living human retina can greatly improve the diagnosis and treatment of glaucoma. However, owing to their translucent soma and tight packing arrangement within the ganglion cell layer (GCL), successful imaging has only been achieved with sophisticated research-grade adaptive optics (AO) systems. For the first time we demonstrate that GCL somas can be resolved and cell morphology can be quantified using non-AO optical coherence tomography (OCT) devices with optimal parameter configuration and post-processing.
Collapse
Affiliation(s)
- Furu Zhang
- Center for Devices and Radiological Health (CDRH), U.S. Food and Drug Administration, Silver Spring, MD 20993, USA
| | - Katherine Kovalick
- Center for Devices and Radiological Health (CDRH), U.S. Food and Drug Administration, Silver Spring, MD 20993, USA
| | - Achyut Raghavendra
- Center for Devices and Radiological Health (CDRH), U.S. Food and Drug Administration, Silver Spring, MD 20993, USA
| | | | - Sina Farsiu
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA
| | - Daniel X. Hammer
- Center for Devices and Radiological Health (CDRH), U.S. Food and Drug Administration, Silver Spring, MD 20993, USA
| | - Zhuolin Liu
- Center for Devices and Radiological Health (CDRH), U.S. Food and Drug Administration, Silver Spring, MD 20993, USA
| |
Collapse
|
15
|
Hamza A, Hayward TM, Majumder A, Brimhall N, Menon R, Ha J. High-resolution optical coherence tomography using a multi-level diffractive lens. OPTICS EXPRESS 2024; 32:27748-27755. [PMID: 39538605 DOI: 10.1364/oe.529870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2024] [Accepted: 07/06/2024] [Indexed: 11/16/2024]
Abstract
We present a high-resolution optical coherence tomography (OCT) imaging system that utilizes a multi-level diffractive lens (MDL) to enhance lateral resolution. The system utilizes a polygon-based swept laser source with a center wavelength of 1,000 nm to achieve an axial resolution of 5.6 µm and an imaging depth of 1.4 mm using the bidirectional configuration of a semiconductor optical amplifier. The MDL significantly enhances the lateral resolution of the system, providing an extended depth of focus of 550 µm with an average lateral resolution of 8.5 µm. The effectiveness of this setup is validated through imaging of phantom and onion samples, demonstrating the system's capability for high-resolution deep tissue imaging. These findings underscore the potential of compact MDLs to significantly enhance the performance of OCT systems, offering a promising direction for advanced high-resolution imaging applications.
Collapse
|
16
|
Yue X, Yang Y, Chen S, Dai H. Statistical optimal parameters obtained by using clinical human ocular aberrations for high-precision aberration measurement. Int Ophthalmol 2024; 44:292. [PMID: 38940969 DOI: 10.1007/s10792-024-03176-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Accepted: 06/15/2024] [Indexed: 06/29/2024]
Abstract
PURPOSE Compared to Shack-Hartmann wavefront sensor (SHWS), the parameters of virtual SHWS (vSHWS) can be easily adjusted to obtain the optimal performance of aberration measurement. Its current optimal parameters are obtained with only a set of statistical aberrations and not statistically significant. Whether the above parameters are consistent with the statistical results of the optimal parameters corresponding to each set of aberrations, and which performance is better if not? The purpose of this study was to answer these questions. METHODS The optimal parameters to reconstruct 624 sets of clinical ocular aberrations in the highest accuracy, including the numbers of sub-apertures (NSAs) and the expansion ratios (ERs) of electric field zero-padding, were determined sequentially in this work. By using wavefront-reconstruction accuracy as an evaluation index, the statistical optimal parameter configuration was selected from some possible configurations determined by the optimal NSAs and ERs. RESULTS The statistical optimal parameters are consistent for normal and abnormal eyes. They are different from the optimal parameters obtained with a set of statistical aberrations from the same 624 sets of aberrations, and the performance using the former is better than that using the latter. The performance using a fixed set of statistical optimal parameters is even close to that using the respective optimal parameters corresponding to each set of aberrations. CONCLUSION The vSHWS configured with a fixed set of statistical optimal parameters can be used for high-precision aberration measurement of both normal and abnormal eyes. The statistical optimal parameters are more suitable for vSHWS than the parameters obtained with a set of statistical aberrations. These conclusions are significant for the designs of vSHWS and also SHWS.
Collapse
Affiliation(s)
- Xian Yue
- Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, 610209, China
- Key Laboratory of Adaptive Optics, Chinese Academy of Sciences, Chengdu, 610209, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Yaliang Yang
- Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, 610209, China.
- Key Laboratory of Adaptive Optics, Chinese Academy of Sciences, Chengdu, 610209, China.
- University of Chinese Academy of Sciences, Beijing, 100049, China.
| | - Shen Chen
- Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, 610209, China
- Key Laboratory of Adaptive Optics, Chinese Academy of Sciences, Chengdu, 610209, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Hao Dai
- Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, 610209, China
- Key Laboratory of Adaptive Optics, Chinese Academy of Sciences, Chengdu, 610209, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| |
Collapse
|
17
|
Torm MEW, Pircher M, Bonnin S, Johannesen J, Klefter ON, Schmidt MF, Frederiksen JL, Lefaudeux N, Andilla J, Valdes C, Loza-Alvarez P, Brea LS, De Jesus DA, Grieve K, Paques M, Larsen M, Gocho K. Detection of capillary abnormalities in early diabetic retinopathy using scanning laser ophthalmoscopy and optical coherence tomography combined with adaptive optics. Sci Rep 2024; 14:13450. [PMID: 38862584 PMCID: PMC11166634 DOI: 10.1038/s41598-024-63749-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Accepted: 05/31/2024] [Indexed: 06/13/2024] Open
Abstract
This study tested if a high-resolution, multi-modal, multi-scale retinal imaging instrument can provide novel information about structural abnormalities in vivo. The study examined 11 patients with very mild to moderate non-proliferative diabetic retinopathy (NPDR) and 10 healthy subjects using fundus photography, optical coherence tomography (OCT), OCT angiography (OCTA), adaptive optics scanning laser ophthalmoscopy (AO-SLO), adaptive optics OCT and OCTA (AO-OCT(A)). Of 21 eyes of 11 patients, 11 had very mild NPDR, 8 had mild NPDR, 2 had moderate NPDR, and 1 had no retinopathy. Using AO-SLO, capillary looping, inflections and dilations were detected in 8 patients with very mild or mild NPDR, and microaneurysms containing hyperreflective granular elements were visible in 9 patients with mild or moderate NPDR. Most of the abnormalities were seen to be perfused in the corresponding OCTA scans while a few capillary loops appeared to be occluded or perfused at a non-detectable flow rate, possibly because of hypoperfusion. In one patient with moderate NPDR, non-perfused capillaries, also called ghost vessels, were identified by alignment of corresponding en face AO-OCT and AO-OCTA images. The combination of multiple non-invasive imaging methods could identify prominent microscopic abnormalities in diabetic retinopathy earlier and more detailed than conventional fundus imaging devices.
Collapse
Affiliation(s)
- Marie Elise Wistrup Torm
- Department of Ophthalmology, Center for Research in Eye Diseases, Rigshospitalet, Section 37, Valdemar Hansens Vej 13, 2600, Glostrup, Denmark.
- Faculty of Health and Medical Sciences, University of Copenhagen, Blegdamsvej 3B, Copenhagen N, Denmark.
| | - Michael Pircher
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20, 1090, Vienna, Austria
| | - Sophie Bonnin
- INSERM-DGOS CIC 1423, CHNO des Quinze-Vingts, 28 Rue de Charenton, 75012, Paris, France
- INSERM, CNRS, Institut de La Vision, Sorbonne Université, 17 Rue Moreau, 75012, Paris, France
- Foundation Rothschild Hospital, 25-29, Rue Manin, 75019, Paris, France
| | - Jesper Johannesen
- Faculty of Health and Medical Sciences, University of Copenhagen, Blegdamsvej 3B, Copenhagen N, Denmark
- Department of Pediatrics, Herlev-Gentofte Hospital, Borgmester Ib Juuls Vej 25C, Herlev, Denmark
- Department of Clinical Research, Steno Diabetes Center Copenhagen, Borgmester Ib Juuls Vej 83, Herlev, Denmark
| | - Oliver Niels Klefter
- Department of Ophthalmology, Center for Research in Eye Diseases, Rigshospitalet, Section 37, Valdemar Hansens Vej 13, 2600, Glostrup, Denmark
- Faculty of Health and Medical Sciences, University of Copenhagen, Blegdamsvej 3B, Copenhagen N, Denmark
| | - Mathias Falck Schmidt
- Faculty of Health and Medical Sciences, University of Copenhagen, Blegdamsvej 3B, Copenhagen N, Denmark
- Department of Neurology, Clinic of Optic Neuritis, The Danish Multiple Sclerosis Center (DMSC), Rigshospitalet, Valdemar Hansens Vej 13, Glostrup, Denmark
| | - Jette Lautrup Frederiksen
- Faculty of Health and Medical Sciences, University of Copenhagen, Blegdamsvej 3B, Copenhagen N, Denmark
- Department of Neurology, Clinic of Optic Neuritis, The Danish Multiple Sclerosis Center (DMSC), Rigshospitalet, Valdemar Hansens Vej 13, Glostrup, Denmark
| | | | - Jordi Andilla
- The Barcelona Institute of Science and Technology, ICFO-Institut de Ciencies Fotoniques, 08860, Castelldefels, Barcelona, Spain
| | - Claudia Valdes
- The Barcelona Institute of Science and Technology, ICFO-Institut de Ciencies Fotoniques, 08860, Castelldefels, Barcelona, Spain
| | - Pablo Loza-Alvarez
- The Barcelona Institute of Science and Technology, ICFO-Institut de Ciencies Fotoniques, 08860, Castelldefels, Barcelona, Spain
| | - Luisa Sanchez Brea
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center, Dr. Molewaterplein 40, Rotterdam, The Netherlands
- Department of Ophthalmology, Erasmus Medical Center, Dr. Molewaterplein 40, Rotterdam, The Netherlands
- The Rotterdam Eye Hospital, The Rotterdam Ophthalmic Institute, Schiedamse Vest 160, Rotterdam, The Netherlands
| | - Danilo Andrade De Jesus
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center, Dr. Molewaterplein 40, Rotterdam, The Netherlands
- Department of Ophthalmology, Erasmus Medical Center, Dr. Molewaterplein 40, Rotterdam, The Netherlands
- The Rotterdam Eye Hospital, The Rotterdam Ophthalmic Institute, Schiedamse Vest 160, Rotterdam, The Netherlands
| | - Kate Grieve
- INSERM-DGOS CIC 1423, CHNO des Quinze-Vingts, 28 Rue de Charenton, 75012, Paris, France
- INSERM, CNRS, Institut de La Vision, Sorbonne Université, 17 Rue Moreau, 75012, Paris, France
| | - Michel Paques
- INSERM-DGOS CIC 1423, CHNO des Quinze-Vingts, 28 Rue de Charenton, 75012, Paris, France
- INSERM, CNRS, Institut de La Vision, Sorbonne Université, 17 Rue Moreau, 75012, Paris, France
| | - Michael Larsen
- Department of Ophthalmology, Center for Research in Eye Diseases, Rigshospitalet, Section 37, Valdemar Hansens Vej 13, 2600, Glostrup, Denmark
- Faculty of Health and Medical Sciences, University of Copenhagen, Blegdamsvej 3B, Copenhagen N, Denmark
| | - Kiyoko Gocho
- INSERM-DGOS CIC 1423, CHNO des Quinze-Vingts, 28 Rue de Charenton, 75012, Paris, France
- INSERM, CNRS, Institut de La Vision, Sorbonne Université, 17 Rue Moreau, 75012, Paris, France
| |
Collapse
|
18
|
Wang CY, Sadrieh FK, Shen YT, Chen SE, Kim S, Chen V, Raghavendra A, Wang D, Saeedi O, Tao Y. MEMO: dataset and methods for robust multimodal retinal image registration with large or small vessel density differences. BIOMEDICAL OPTICS EXPRESS 2024; 15:3457-3479. [PMID: 38855695 PMCID: PMC11161385 DOI: 10.1364/boe.516481] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 03/20/2024] [Accepted: 04/18/2024] [Indexed: 06/11/2024]
Abstract
The measurement of retinal blood flow (RBF) in capillaries can provide a powerful biomarker for the early diagnosis and treatment of ocular diseases. However, no single modality can determine capillary flowrates with high precision. Combining erythrocyte-mediated angiography (EMA) with optical coherence tomography angiography (OCTA) has the potential to achieve this goal, as EMA can measure the absolute RBF of retinal microvasculature and OCTA can provide the structural images of capillaries. However, multimodal retinal image registration between these two modalities remains largely unexplored. To fill this gap, we establish MEMO, the first public multimodal EMA and OCTA retinal image dataset. A unique challenge in multimodal retinal image registration between these modalities is the relatively large difference in vessel density (VD). To address this challenge, we propose a segmentation-based deep-learning framework (VDD-Reg), which provides robust results despite differences in vessel density. VDD-Reg consists of a vessel segmentation module and a registration module. To train the vessel segmentation module, we further designed a two-stage semi-supervised learning framework (LVD-Seg) combining supervised and unsupervised losses. We demonstrate that VDD-Reg outperforms existing methods quantitatively and qualitatively for cases of both small VD differences (using the CF-FA dataset) and large VD differences (using our MEMO dataset). Moreover, VDD-Reg requires as few as three annotated vessel segmentation masks to maintain its accuracy, demonstrating its feasibility.
Collapse
Affiliation(s)
- Chiao-Yi Wang
- Department of Bioengineering, University of Maryland, College Park, MD 20742, USA
| | | | - Yi-Ting Shen
- Department of Electrical and Computer Engineering, University of Maryland, College Park, MD 20742, USA
| | - Shih-En Chen
- Department of Ophthalmology and Visual Sciences, University of Maryland School of Medicine, Baltimore, MD 21201, USA
| | - Sarah Kim
- Department of Ophthalmology and Visual Sciences, University of Maryland School of Medicine, Baltimore, MD 21201, USA
| | - Victoria Chen
- Department of Ophthalmology and Visual Sciences, University of Maryland School of Medicine, Baltimore, MD 21201, USA
| | - Achyut Raghavendra
- Department of Ophthalmology and Visual Sciences, University of Maryland School of Medicine, Baltimore, MD 21201, USA
| | - Dongyi Wang
- Department of Biological and Agricultural Engineering, University of Arkansas, Fayetteville, AR 72701, USA
| | - Osamah Saeedi
- Department of Ophthalmology and Visual Sciences, University of Maryland School of Medicine, Baltimore, MD 21201, USA
| | - Yang Tao
- Department of Bioengineering, University of Maryland, College Park, MD 20742, USA
| |
Collapse
|
19
|
Das V, Zhang F, Bower AJ, Li J, Liu T, Aguilera N, Alvisio B, Liu Z, Hammer DX, Tam J. Revealing speckle obscured living human retinal cells with artificial intelligence assisted adaptive optics optical coherence tomography. COMMUNICATIONS MEDICINE 2024; 4:68. [PMID: 38600290 PMCID: PMC11006674 DOI: 10.1038/s43856-024-00483-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Accepted: 03/13/2024] [Indexed: 04/12/2024] Open
Abstract
BACKGROUND In vivo imaging of the human retina using adaptive optics optical coherence tomography (AO-OCT) has transformed medical imaging by enabling visualization of 3D retinal structures at cellular-scale resolution, including the retinal pigment epithelial (RPE) cells, which are essential for maintaining visual function. However, because noise inherent to the imaging process (e.g., speckle) makes it difficult to visualize RPE cells from a single volume acquisition, a large number of 3D volumes are typically averaged to improve contrast, substantially increasing the acquisition duration and reducing the overall imaging throughput. METHODS Here, we introduce parallel discriminator generative adversarial network (P-GAN), an artificial intelligence (AI) method designed to recover speckle-obscured cellular features from a single AO-OCT volume, circumventing the need for acquiring a large number of volumes for averaging. The combination of two parallel discriminators in P-GAN provides additional feedback to the generator to more faithfully recover both local and global cellular structures. Imaging data from 8 eyes of 7 participants were used in this study. RESULTS We show that P-GAN not only improves RPE cell contrast by 3.5-fold, but also improves the end-to-end time required to visualize RPE cells by 99-fold, thereby enabling large-scale imaging of cells in the living human eye. RPE cell spacing measured across a large set of AI recovered images from 3 participants were in agreement with expected normative ranges. CONCLUSIONS The results demonstrate the potential of AI assisted imaging in overcoming a key limitation of RPE imaging and making it more accessible in a routine clinical setting.
Collapse
Affiliation(s)
- Vineeta Das
- National Eye Institute, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Furu Zhang
- National Eye Institute, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Andrew J Bower
- National Eye Institute, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Joanne Li
- National Eye Institute, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Tao Liu
- National Eye Institute, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Nancy Aguilera
- National Eye Institute, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Bruno Alvisio
- National Eye Institute, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Zhuolin Liu
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD, 20993, USA
| | - Daniel X Hammer
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD, 20993, USA
| | - Johnny Tam
- National Eye Institute, National Institutes of Health, Bethesda, MD, 20892, USA.
| |
Collapse
|
20
|
Corradetti G, Verma A, Tojjar J, Almidani L, Oncel D, Emamverdi M, Bradley A, Lindenberg S, Nittala MG, Sadda SR. Retinal Imaging Findings in Inherited Retinal Diseases. J Clin Med 2024; 13:2079. [PMID: 38610844 PMCID: PMC11012835 DOI: 10.3390/jcm13072079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Revised: 03/19/2024] [Accepted: 03/27/2024] [Indexed: 04/14/2024] Open
Abstract
Inherited retinal diseases (IRDs) represent one of the major causes of progressive and irreversible vision loss in the working-age population. Over the last few decades, advances in retinal imaging have allowed for an improvement in the phenotypic characterization of this group of diseases and have facilitated phenotype-to-genotype correlation studies. As a result, the number of clinical trials targeting IRDs has steadily increased, and commensurate to this, the need for novel reproducible outcome measures and endpoints has grown. This review aims to summarize and describe the clinical presentation, characteristic imaging findings, and imaging endpoint measures that are being used in clinical research on IRDs. For the purpose of this review, IRDs have been divided into four categories: (1) panretinal pigmentary retinopathies affecting rods or cones; (2) macular dystrophies; (3) stationary conditions; (4) hereditary vitreoretinopathies.
Collapse
Affiliation(s)
- Giulia Corradetti
- Doheny Eye Institute, Pasadena, CA 91103, USA (J.T.); (L.A.)
- Department of Ophthalmology, David Geffen School of Medicine at UCLA, Los Angeles, CA 90095, USA
| | - Aditya Verma
- Doheny Eye Institute, Pasadena, CA 91103, USA (J.T.); (L.A.)
- Department of Ophthalmology and Visual Sciences, University of Louisville, Louisville, KY 40202, USA
| | - Jasaman Tojjar
- Doheny Eye Institute, Pasadena, CA 91103, USA (J.T.); (L.A.)
- Department of Ophthalmology, David Geffen School of Medicine at UCLA, Los Angeles, CA 90095, USA
| | - Louay Almidani
- Doheny Eye Institute, Pasadena, CA 91103, USA (J.T.); (L.A.)
- Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA
| | - Deniz Oncel
- Doheny Eye Institute, Pasadena, CA 91103, USA (J.T.); (L.A.)
- Stritch School of Medicine, Loyola University Chicago, Chicago, IL 60153, USA
| | - Mehdi Emamverdi
- Doheny Eye Institute, Pasadena, CA 91103, USA (J.T.); (L.A.)
| | - Alec Bradley
- Department of Ophthalmology and Visual Sciences, University of Louisville, Louisville, KY 40202, USA
| | | | | | - SriniVas R. Sadda
- Doheny Eye Institute, Pasadena, CA 91103, USA (J.T.); (L.A.)
- Department of Ophthalmology, David Geffen School of Medicine at UCLA, Los Angeles, CA 90095, USA
| |
Collapse
|
21
|
Britten-Jones AC, Thai L, Flanagan JPM, Bedggood PA, Edwards TL, Metha AB, Ayton LN. Adaptive optics imaging in inherited retinal diseases: A scoping review of the clinical literature. Surv Ophthalmol 2024; 69:51-66. [PMID: 37778667 DOI: 10.1016/j.survophthal.2023.09.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Revised: 09/22/2023] [Accepted: 09/25/2023] [Indexed: 10/03/2023]
Abstract
Adaptive optics (AO) imaging enables direct, objective assessments of retinal cells. Applications of AO show great promise in advancing our understanding of the etiology of inherited retinal disease (IRDs) and discovering new imaging biomarkers. This scoping review systematically identifies and summarizes clinical studies evaluating AO imaging in IRDs. Ovid MEDLINE and EMBASE were searched on February 6, 2023. Studies describing AO imaging in monogenic IRDs were included. Study screening and data extraction were performed by 2 reviewers independently. This review presents (1) a broad overview of the dominant areas of research; (2) a summary of IRD characteristics revealed by AO imaging; and (3) a discussion of methodological considerations relating to AO imaging in IRDs. From 140 studies with AO outcomes, including 2 following subretinal gene therapy treatments, 75% included fewer than 10 participants with AO imaging data. Of 100 studies that included participants' genetic diagnoses, the most common IRD genes with AO outcomes are CNGA3, CNGB3, CHM, USH2A, and ABCA4. Confocal reflectance AO scanning laser ophthalmoscopy was the most reported imaging modality, followed by flood-illuminated AO and split-detector AO. The most common outcome was cone density, reported quantitatively in 56% of studies. Future research areas include guidelines to reduce variability in the reporting of AO methodology and a focus on functional AO techniques to guide the development of therapeutic interventions.
Collapse
Affiliation(s)
- Alexis Ceecee Britten-Jones
- Department of Optometry and Vision Sciences, Faculty of Medicine, Dentistry and Health Sciences, University of Melbourne, Parkville, VIC, Australia; Department of Surgery (Ophthalmology), Faculty of Medicine, Dentistry and Health Sciences, University of Melbourne, Parkville, VIC, Australia; Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia.
| | - Lawrence Thai
- Department of Surgery (Ophthalmology), Faculty of Medicine, Dentistry and Health Sciences, University of Melbourne, Parkville, VIC, Australia; Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| | - Jeremy P M Flanagan
- Department of Surgery (Ophthalmology), Faculty of Medicine, Dentistry and Health Sciences, University of Melbourne, Parkville, VIC, Australia; Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| | - Phillip A Bedggood
- Department of Optometry and Vision Sciences, Faculty of Medicine, Dentistry and Health Sciences, University of Melbourne, Parkville, VIC, Australia
| | - Thomas L Edwards
- Department of Surgery (Ophthalmology), Faculty of Medicine, Dentistry and Health Sciences, University of Melbourne, Parkville, VIC, Australia; Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| | - Andrew B Metha
- Department of Optometry and Vision Sciences, Faculty of Medicine, Dentistry and Health Sciences, University of Melbourne, Parkville, VIC, Australia
| | - Lauren N Ayton
- Department of Optometry and Vision Sciences, Faculty of Medicine, Dentistry and Health Sciences, University of Melbourne, Parkville, VIC, Australia; Department of Surgery (Ophthalmology), Faculty of Medicine, Dentistry and Health Sciences, University of Melbourne, Parkville, VIC, Australia; Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| |
Collapse
|
22
|
Chauhan BC. Understanding the Increasing Role of Optical Coherence Tomography in Glaucoma Diagnostics and Disease Progression. JAMA Ophthalmol 2023; 141:890. [PMID: 37589988 DOI: 10.1001/jamaophthalmol.2023.3732] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/18/2023]
Affiliation(s)
- Balwantray C Chauhan
- Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Nova Scotia, Canada
- Nova Scotia Health Authority, Halifax, Nova Scotia, Canada
| |
Collapse
|
23
|
Wongwai J, Buranasiri P, Pasupa K, Manassakorn A. Analysis of volumetric 3D reconstruction of lamina cribrosa images from swept-source optical coherence tomography in glaucomatous and healthy subjects. BIOMEDICAL OPTICS EXPRESS 2023; 14:4627-4643. [PMID: 37791255 PMCID: PMC10545178 DOI: 10.1364/boe.497242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Revised: 07/18/2023] [Accepted: 07/24/2023] [Indexed: 10/05/2023]
Abstract
This study demonstrates the 3D visualization of the lamina cribrosa (LC) structure and its correlation with volumetric data, pore volume, and disc area in glaucomatous and non-glaucomatous eyes. The participant cohort included 65 glaucomatous and 58 non-glaucomatous eyes (13 suspected glaucoma and 45 normal). An ophthalmologist diagnosed glaucoma patients and all subjects were over 18 years old, passed a visual field test, and underwent optical coherence tomography (OCT) examinations. LC images were obtained using the DRI OCT Triton, while optic disc images were obtained from the enface image of the Cirrus HD-OCT 5000. Since LC images alone did not provide clear edge information, we used optic disc images as a reference for edge detection. To achieve this, we employed a fine-tuned model, specifically a pre-trained U-shaped Encoder-Decoder Network with Attention. This model was used to obtain a segmented mask, which was then aligned and utilized to locate the edge of the LC in the LC images. A blood vessel mask was created to remove blood vessels, as they can interfere with the accurate visualization and analysis of LC characteristics. This step allowed for the 3D reconstruction of the LC structure without the presence of blood vessels. Correlations between LC volume, pore volume, and pore volume to LC volume were calculated separately for glaucomatous and non-glaucomatous eyes. We divided the areas for considering the LC structure into three types: overall, quadrants, and 12-clock-hour sectors. Based on the experimental results, we found that the pore volume and pore-to-LC volume were different between glaucoma and normal across all areas considered. In conclusion, this research generated 3D images of the LC from OCT images using computer techniques, showcasing a microstructure that closely resembles the actual LC. Statistical methods were employed to calculate and analyze the differences observed between the two groups of samples.
Collapse
Affiliation(s)
- Jutamash Wongwai
- Artificial Intelligence Photonics Advanced
Research Laboratory, Department of Physics, School of Science, King Mongkut’s Institute of Technology Ladkrabang, Bangkok 10520, Thailand
| | - Prathan Buranasiri
- Artificial Intelligence Photonics Advanced
Research Laboratory, Department of Physics, School of Science, King Mongkut’s Institute of Technology Ladkrabang, Bangkok 10520, Thailand
- Electronic and Optoelectronic Device
Research Unit, School of Science, King Mongkut’s
Institute of Technology Ladkrabang, Bangkok 10520,
Thailand
| | - Kitsuchart Pasupa
- School of Information Technology,
King Mongkut’s Institute of Technology
Ladkrabang, Bangkok 10520, Thailand
| | - Anita Manassakorn
- Center of Excellence in Glaucoma,
Department of Ophthalmology, Faculty of Medicine,
Chulalongkorn University and King Chulalongkorn Memorial
Hospital, The Thai Red Cross Society, Bangkok 10330,
Thailand
| |
Collapse
|
24
|
Untracht GR, Chen M, Wijesinghe P, Mas J, Yura HT, Marti D, Andersen PE, Dholakia K. Spatially offset optical coherence tomography: Leveraging multiple scattering for high-contrast imaging at depth in turbid media. SCIENCE ADVANCES 2023; 9:eadh5435. [PMID: 37418534 DOI: 10.1126/sciadv.adh5435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Accepted: 06/05/2023] [Indexed: 07/09/2023]
Abstract
The penetration depth of optical coherence tomography (OCT) reaches well beyond conventional microscopy; however, signal reduction with depth leads to rapid degradation of the signal below the noise level. The pursuit of imaging at depth has been largely approached by extinguishing multiple scattering. However, in OCT, multiple scattering substantially contributes to image formation at depth. Here, we investigate the role of multiple scattering in OCT image contrast and postulate that, in OCT, multiple scattering can enhance image contrast at depth. We introduce an original geometry that completely decouples the incident and collection fields by introducing a spatial offset between them, leading to preferential collection of multiply scattered light. A wave optics-based theoretical framework supports our experimentally demonstrated improvement in contrast. The effective signal attenuation can be reduced by more than 24 decibels. Notably, a ninefold enhancement in image contrast at depth is observed in scattering biological samples. This geometry enables a powerful capacity to dynamically tune for contrast at depth.
Collapse
Affiliation(s)
- Gavrielle R Untracht
- Department of Health Technology, Technical University of Denmark, Kongens Lyngby 2800, Denmark
| | - Mingzhou Chen
- SUPA, School of Physics and Astronomy, University of St Andrews, St Andrews KY16 9SS, UK
| | - Philip Wijesinghe
- SUPA, School of Physics and Astronomy, University of St Andrews, St Andrews KY16 9SS, UK
| | - Josep Mas
- SUPA, School of Physics and Astronomy, University of St Andrews, St Andrews KY16 9SS, UK
| | - Harold T Yura
- Electronics and Photonics Laboratory, The Aerospace Corporation, El Segundo, CA 90245, USA
| | - Dominik Marti
- Department of Health Technology, Technical University of Denmark, Kongens Lyngby 2800, Denmark
| | - Peter E Andersen
- Department of Health Technology, Technical University of Denmark, Kongens Lyngby 2800, Denmark
| | - Kishan Dholakia
- SUPA, School of Physics and Astronomy, University of St Andrews, St Andrews KY16 9SS, UK
- Centre of Light for Life and School of Biological Sciences, University of Adelaide, Adelaide, SA 5005, Australia
| |
Collapse
|
25
|
Han L, Bizheva K. Correcting spatial-spectral crosstalk and chromatic aberrations in broadband line-scan spectral-domain OCT images. BIOMEDICAL OPTICS EXPRESS 2023; 14:3344-3361. [PMID: 37497512 PMCID: PMC10368066 DOI: 10.1364/boe.488881] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 05/30/2023] [Accepted: 06/02/2023] [Indexed: 07/28/2023]
Abstract
Digital correction of optical aberrations allows for high-resolution imaging across the full depth range in optical coherence tomography (OCT). Many digital aberration correction (DAC) methods have been proposed in the past to evaluate and correct monochromatic error in OCT images. However, other factors that deteriorate the image quality have not been fully investigated. Specifically, in a broadband line-scan spectral-domain OCT system (LS-SD-OCT), photons with different wavelengths scattered from the same transverse location and in the imaged object will be projected onto different spatial coordinates onto the 2D camera sensor, which in this work is defined as spatial-spectral crosstalk. In addition, chromatic aberrations in both axial and lateral directions are not negligible for broad spectral bandwidths. Here we present a novel approach to digital recovery of the spatial resolution in images acquired with a broadband LS-SD-OCT, which addresses these two main factors that limit the effectiveness of DAC for restoring diffraction-limited resolution in LS-SD-OCT images. In the proposed approach, spatial-spectral crosstalk and chromatic aberrations are suppressed by the registration of monochromatic sub-band tomograms that are digitally corrected for aberrations. The new method was validated by imaging a standard resolution target, a microspheres phantom, and different biological tissues. LS-SD-OCT technology combined with the proposed novel image reconstruction method could be a valuable research tool for various biomedical and clinical applications.
Collapse
Affiliation(s)
- Le Han
- Department of Physics and Astronomy, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Kostadinka Bizheva
- Department of Physics and Astronomy, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
- Department of Systems Design Engineering, University of Waterloo, Waterloo, Ontario, Canada
- School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
26
|
Feng BY, Guo H, Xie M, Boominathan V, Sharma MK, Veeraraghavan A, Metzler CA. NeuWS: Neural wavefront shaping for guidestar-free imaging through static and dynamic scattering media. SCIENCE ADVANCES 2023; 9:eadg4671. [PMID: 37379386 DOI: 10.1126/sciadv.adg4671] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Accepted: 05/23/2023] [Indexed: 06/30/2023]
Abstract
Diffraction-limited optical imaging through scattering media has the potential to transform many applications such as airborne and space-based imaging (through the atmosphere), bioimaging (through skin and human tissue), and fiber-based imaging (through fiber bundles). Existing wavefront shaping methods can image through scattering media and other obscurants by optically correcting wavefront aberrations using high-resolution spatial light modulators-but these methods generally require (i) guidestars, (ii) controlled illumination, (iii) point scanning, and/or (iv) statics scenes and aberrations. We propose neural wavefront shaping (NeuWS), a scanning-free wavefront shaping technique that integrates maximum likelihood estimation, measurement modulation, and neural signal representations to reconstruct diffraction-limited images through strong static and dynamic scattering media without guidestars, sparse targets, controlled illumination, nor specialized image sensors. We experimentally demonstrate guidestar-free, wide field-of-view, high-resolution, diffraction-limited imaging of extended, nonsparse, and static/dynamic scenes captured through static/dynamic aberrations.
Collapse
Affiliation(s)
- Brandon Y Feng
- Department of Computer Science, The University of Maryland, College Park, College Park, MD 20742, USA
| | - Haiyun Guo
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, USA
| | - Mingyang Xie
- Department of Computer Science, The University of Maryland, College Park, College Park, MD 20742, USA
| | - Vivek Boominathan
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, USA
| | - Manoj K Sharma
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, USA
| | - Ashok Veeraraghavan
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, USA
| | - Christopher A Metzler
- Department of Computer Science, The University of Maryland, College Park, College Park, MD 20742, USA
| |
Collapse
|
27
|
Williams DR, Burns SA, Miller DT, Roorda A. Evolution of adaptive optics retinal imaging [Invited]. BIOMEDICAL OPTICS EXPRESS 2023; 14:1307-1338. [PMID: 36950228 PMCID: PMC10026580 DOI: 10.1364/boe.485371] [Citation(s) in RCA: 28] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Accepted: 02/02/2023] [Indexed: 05/02/2023]
Abstract
This review describes the progress that has been achieved since adaptive optics (AO) was incorporated into the ophthalmoscope a quarter of a century ago, transforming our ability to image the retina at a cellular spatial scale inside the living eye. The review starts with a comprehensive tabulation of AO papers in the field and then describes the technological advances that have occurred, notably through combining AO with other imaging modalities including confocal, fluorescence, phase contrast, and optical coherence tomography. These advances have made possible many scientific discoveries from the first maps of the topography of the trichromatic cone mosaic to exquisitely sensitive measures of optical and structural changes in photoreceptors in response to light. The future evolution of this technology is poised to offer an increasing array of tools to measure and monitor in vivo retinal structure and function with improved resolution and control.
Collapse
Affiliation(s)
- David R. Williams
- The Institute of Optics and the Center for
Visual Science, University of Rochester,
Rochester NY, USA
| | - Stephen A. Burns
- School of Optometry, Indiana
University at Bloomington, Bloomington IN, USA
| | - Donald T. Miller
- School of Optometry, Indiana
University at Bloomington, Bloomington IN, USA
| | - Austin Roorda
- Herbert Wertheim School of Optometry and
Vision Science, University of California at Berkeley, Berkeley CA, USA
| |
Collapse
|
28
|
Abstract
We examine the inverse problem of retrieving sample refractive index information in the context of optical coherence tomography. Using two separate approaches, we discuss the limitations of the inverse problem which lead to it being ill-posed, primarily as a consequence of the limited viewing angles available in the reflection geometry. This is first considered from the theoretical point of view of diffraction tomography under a weak scattering approximation. We then investigate the full non-linear inverse problem using a variational approach. This presents another illustration of the non-uniqueness of the solution, and shows that even the non-linear (strongly scattering) scenario suffers a similar fate as the linear problem, with the observable spatial Fourier components of the sample occupying a limited support. Through examples we demonstrate how the solutions to the inverse problem compare when using the variational and diffraction-tomography approaches.
Collapse
|
29
|
Xu W, Wang H. Using beam-offset optical coherence tomography to reconstruct backscattered photon profiles in scattering media. BIOMEDICAL OPTICS EXPRESS 2022; 13:6124-6135. [PMID: 36733762 PMCID: PMC9872868 DOI: 10.1364/boe.469082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 09/10/2022] [Accepted: 10/09/2022] [Indexed: 06/18/2023]
Abstract
Raster scanning imaging technologies capture least scattered photons (LSPs) and reject multiple scattered photons (MSPs) in backscattered photons to image the underlying structures of a scattering medium. However, MSPs can still squeeze into the images, resulting in limited imaging depth, degraded contrast, and significantly reduced lateral resolution. Great efforts have been made to understand how MSPs affect imaging performance through modeling, but the techniques for visualizing the backscattered photon profile (BSPP) in scattering media during imaging are unavailable. Here, a method of reconstructing BSPP is demonstrated using beam-offset optical coherence tomography (OCT), in which OCT images are acquired at offset positions from the illumination beam. The separation of LSPs and MSPs based on the BSPP enables quantification of imaging depth, contrast, and lateral resolution, as well as access to the depth-resolved modulated transfer function (MTF). This approach presents great opportunities for better retrieving tissue optical properties, correctly interpreting images, or directly using MTF as the feedback for adaptive optical imaging.
Collapse
Affiliation(s)
- Weiming Xu
- The Department of Chemical, Paper, and Biomedical Engineering, Miami University, Oxford, 45056 OH, USA
- The Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
| | - Hui Wang
- The Department of Chemical, Paper, and Biomedical Engineering, Miami University, Oxford, 45056 OH, USA
| |
Collapse
|
30
|
Liu Z, Zhang F, Zucca K, Agrawal A, Hammer DX. Ultrahigh-speed multimodal adaptive optics system for microscopic structural and functional imaging of the human retina. BIOMEDICAL OPTICS EXPRESS 2022; 13:5860-5878. [PMID: 36733751 PMCID: PMC9872887 DOI: 10.1364/boe.462594] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 09/16/2022] [Accepted: 09/20/2022] [Indexed: 05/02/2023]
Abstract
We describe the design and performance of a multimodal and multifunctional adaptive optics (AO) system that combines scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT) for simultaneous retinal imaging at 13.4 Hz. The high-speed AO-OCT channel uses a 3.4 MHz Fourier-domain mode-locked (FDML) swept source. The system achieves exquisite resolution and sensitivity for pan-macular and transretinal visualization of retinal cells and structures while providing a functional assessment of the cone photoreceptors. The ultra-high speed also enables wide-field scans for clinical usability and angiography for vascular visualization. The FDA FDML-AO system is a powerful platform for studying various retinal and neurological diseases for vision science research, retina physiology investigation, and biomarker development.
Collapse
Affiliation(s)
- Zhuolin Liu
- Center for Devices and Radiological Health
(CDRH), U. S. Food and Drug Administration (FDA), Silver Spring, Maryland 20993, USA
| | - Furu Zhang
- Center for Devices and Radiological Health
(CDRH), U. S. Food and Drug Administration (FDA), Silver Spring, Maryland 20993, USA
- Co-first author
| | - Kelvy Zucca
- Center for Devices and Radiological Health
(CDRH), U. S. Food and Drug Administration (FDA), Silver Spring, Maryland 20993, USA
| | - Anant Agrawal
- Center for Devices and Radiological Health
(CDRH), U. S. Food and Drug Administration (FDA), Silver Spring, Maryland 20993, USA
| | - Daniel X. Hammer
- Center for Devices and Radiological Health
(CDRH), U. S. Food and Drug Administration (FDA), Silver Spring, Maryland 20993, USA
| |
Collapse
|
31
|
Nanegrungsunk O, Patikulsila D, Sadda SR. Ophthalmic imaging in diabetic retinopathy: A review. Clin Exp Ophthalmol 2022; 50:1082-1096. [PMID: 36102668 PMCID: PMC10088017 DOI: 10.1111/ceo.14170] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Revised: 09/01/2022] [Accepted: 09/09/2022] [Indexed: 11/30/2022]
Abstract
Retinal imaging has been a key tool in the diagnosis, evaluation, management and documentation of diabetic retinopathy (DR) and diabetic macular oedema (DMO) for many decades. Imaging technologies have rapidly evolved over the last few decades, yielding images with higher resolution and contrast with less time, effort and invasiveness. While many retinal imaging technologies provide detailed insight into retinal structure such as colour reflectance photography and optical coherence tomography (OCT), others such as fluorescein or OCT angiography and oximetry provide dynamic and functional information. Many other novel imaging technologies are in development and are poised to further enhance our evaluation of patients with DR.
Collapse
Affiliation(s)
- Onnisa Nanegrungsunk
- Doheny Imaging Reading Center Doheny Eye Institute Pasadena California USA
- David Geffen School of Medicine University of California‐Los Angeles Los Angeles California USA
- Retina Division, Department of Ophthalmology Chiang Mai University Chiang Mai Thailand
| | - Direk Patikulsila
- Retina Division, Department of Ophthalmology Chiang Mai University Chiang Mai Thailand
| | - Srinivas R. Sadda
- Doheny Imaging Reading Center Doheny Eye Institute Pasadena California USA
- David Geffen School of Medicine University of California‐Los Angeles Los Angeles California USA
| |
Collapse
|
32
|
Pham AT, Onghanseng N, Halim MS, Ormaechea MS, Hassan M, Akhavanrezayat A, Uludag G, Tran ANT, Razeen MM, Sredar N, Dubra A, Nguyen QD. Reflectance adaptive optics findings in a patient with Vogt-Koyanagi-Harada disease. Am J Ophthalmol Case Rep 2022; 27:101660. [PMID: 35880207 PMCID: PMC9307596 DOI: 10.1016/j.ajoc.2022.101660] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Revised: 05/25/2022] [Accepted: 07/10/2022] [Indexed: 11/22/2022] Open
Abstract
Purpose To describe the reflectance adaptive optics scanning laser ophthalmoscopy (AOSLO) findings in different stages of Vogt-Koyanagi-Harada (VKH) disease and correlate them to visual gain post treatment. Confocal (cAOSLO) and non-confocal split-detector AOSLO (sdAOSLO) were used to assess longitudinally the status of the photoreceptors in a patient with VKH managed on corticosteroid and immunomodulatory therapy. Observation A 32-year-old Japanese American female presented with a 2-week history of blurred vision in both eyes (OU) and worsening headache previously diagnosed as a case of VKH and treated with high dose oral prednisone. At the time of presentation, though vision was improving, and frank serous retinal detachments were absent, spectral domain optical coherence tomography (SD-OCT) showed presence of residual subretinal fluid with disruption of the photoreceptor inner segments and outer segments (IS/OS) involving OU. The photoreceptor mosaic at the foveal center appeared very sparse with large areas devoid of visible photoreceptors on cAOSLO, in agreement with the SD-OCT data. sdAOSLO imaging over the same location shows a higher number of contiguous photoreceptors. After imaging, the patient was started on mycophenolate mofetil as steroid-sparing long-term therapy. Three months later, visual acuity improved to 20/20 OU, and SD-OCT showed almost complete resolution of subretinal fluid with significant improvement of the IS/OS SD-OCT signal, OU. cAOSLO imaging revealed a contiguous photoreceptor mosaic without gaps and of normal appearance. Conclusions and Importance VKH patients may demonstrate transient photoreceptor abnormalities on SD-OCT and cAOSLO imaging. sdAOSLO imaging revealed intact photoreceptor segments in areas that appeared as voids on cAOSLO, which later showed structural recovery on SD-OCT and cAOSLO. Therefore, sdAOSLO may predict potential for improvement in patients wherein there appears to be photoreceptor loss in cAOSLO and/or SD-OCT.
Collapse
|
33
|
Ong J, Zarnegar A, Corradetti G, Singh SR, Chhablani J. Advances in Optical Coherence Tomography Imaging Technology and Techniques for Choroidal and Retinal Disorders. J Clin Med 2022; 11:jcm11175139. [PMID: 36079077 PMCID: PMC9457394 DOI: 10.3390/jcm11175139] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 08/27/2022] [Accepted: 08/28/2022] [Indexed: 11/16/2022] Open
Abstract
Optical coherence tomography (OCT) imaging has played a pivotal role in the field of retina. This light-based, non-invasive imaging modality provides high-quality, cross-sectional analysis of the retina and has revolutionized the diagnosis and management of retinal and choroidal diseases. Since its introduction in the early 1990s, OCT technology has continued to advance to provide quicker acquisition times and higher resolution. In this manuscript, we discuss some of the most recent advances in OCT technology and techniques for choroidal and retinal diseases. The emerging innovations discussed include wide-field OCT, adaptive optics OCT, polarization sensitive OCT, full-field OCT, hand-held OCT, intraoperative OCT, at-home OCT, and more. The applications of these rising OCT systems and techniques will allow for a closer monitoring of chorioretinal diseases and treatment response, more robust analysis in basic science research, and further insights into surgical management. In addition, these innovations to optimize visualization of the choroid and retina offer a promising future for advancing our understanding of the pathophysiology of chorioretinal diseases.
Collapse
Affiliation(s)
- Joshua Ong
- Department of Ophthalmology, University of Pittsburgh School of Medicine, Pittsburgh, PA 15213, USA
| | - Arman Zarnegar
- Department of Ophthalmology, University of Pittsburgh School of Medicine, Pittsburgh, PA 15213, USA
| | - Giulia Corradetti
- Department of Ophthalmology, Doheny Eye Institute, Los Angeles, CA 90095, USA
- Stein Eye Institute, David Geffen School of Medicine at the University of California, Los Angeles, CA 90033, USA
| | | | - Jay Chhablani
- Department of Ophthalmology, University of Pittsburgh School of Medicine, Pittsburgh, PA 15213, USA
- Correspondence:
| |
Collapse
|
34
|
Guest Edited Collection: Quantitative and computational techniques in optical coherence tomography. Sci Rep 2022; 12:11808. [PMID: 35821223 PMCID: PMC9276651 DOI: 10.1038/s41598-022-15424-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
|
35
|
Multi-modal and multi-scale clinical retinal imaging system with pupil and retinal tracking. Sci Rep 2022; 12:9577. [PMID: 35688890 PMCID: PMC9187716 DOI: 10.1038/s41598-022-13631-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Accepted: 05/17/2022] [Indexed: 11/08/2022] Open
Abstract
We present a compact multi-modal and multi-scale retinal imaging instrument with an angiographic functional extension for clinical use. The system integrates scanning laser ophthalmoscopy (SLO), optical coherence tomography (OCT) and OCT angiography (OCTA) imaging modalities and provides multi-scale fields of view. For high resolution, and high lateral resolution in particular, cellular imaging correction of aberrations by adaptive optics (AO) is employed. The entire instrument has a compact design and the scanning head is mounted on motorized translation stages that enable 3D self-alignment with respect to the subject's eye by tracking the pupil position. Retinal tracking, based on the information provided by SLO, is incorporated in the instrument to compensate for retinal motion during OCT imaging. The imaging capabilities of the multi-modal and multi-scale instrument were tested by imaging healthy volunteers and patients.
Collapse
|
36
|
Tomczewski S, Węgrzyn P, Borycki D, Auksorius E, Wojtkowski M, Curatolo A. Light-adapted flicker optoretinograms captured with a spatio-temporal optical coherence-tomography (STOC-T) system. BIOMEDICAL OPTICS EXPRESS 2022; 13:2186-2201. [PMID: 35519256 PMCID: PMC9045926 DOI: 10.1364/boe.444567] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Revised: 02/20/2022] [Accepted: 02/23/2022] [Indexed: 06/14/2023]
Abstract
For many years electroretinography (ERG) has been used for obtaining information about the retinal physiological function. More recently, a new technique called optoretinography (ORG) has been developed. In one form of this technique, the physiological response of retinal photoreceptors to visible light, resulting in a nanometric photoreceptor optical path length change, is measured by phase-sensitive optical coherence tomography (OCT). To date, a limited number of studies with phase-based ORG measured the retinal response to a flickering light stimulation. In this work, we use a spatio-temporal optical coherence tomography (STOC-T) system to capture optoretinograms with a flickering stimulus over a 1.7 × 0.85 mm2 area of a light-adapted retina located between the fovea and the optic nerve. We show that we can detect statistically-significant differences in the photoreceptor optical path length (OPL) modulation amplitudes in response to different flicker frequencies and with better signal to noise ratios (SNRs) than for a dark-adapted eye. We also demonstrate the ability to spatially map such response to a patterned stimulus with light stripes flickering at different frequencies, highlighting the prospect of characterizing the spatially-resolved temporal-frequency response of the retina with ORG.
Collapse
Affiliation(s)
- Sławomir Tomczewski
- International Centre for Translational Eye Research, Skierniewicka 10A, 01-230, Warszawa, Poland
- Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warszawa, Poland
- Equal contributors
| | - Piotr Węgrzyn
- International Centre for Translational Eye Research, Skierniewicka 10A, 01-230, Warszawa, Poland
- Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warszawa, Poland
- Faculty of Physics, University of Warsaw, Pasteura 5, 02-093 Warszawa, Poland
- Equal contributors
| | - Dawid Borycki
- International Centre for Translational Eye Research, Skierniewicka 10A, 01-230, Warszawa, Poland
- Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warszawa, Poland
| | - Egidijus Auksorius
- International Centre for Translational Eye Research, Skierniewicka 10A, 01-230, Warszawa, Poland
- Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warszawa, Poland
- Center for Physical Sciences and Technology (FTMC), Saulėtekio al. 3, LT-10257 Vilnius, Lithuania
| | - Maciej Wojtkowski
- International Centre for Translational Eye Research, Skierniewicka 10A, 01-230, Warszawa, Poland
- Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warszawa, Poland
| | - Andrea Curatolo
- International Centre for Translational Eye Research, Skierniewicka 10A, 01-230, Warszawa, Poland
- Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warszawa, Poland
| |
Collapse
|
37
|
Amplitude Zone Plate in Adaptive Optics: Proposal of the Principle. PHOTONICS 2022. [DOI: 10.3390/photonics9030163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
One of the main elements in hardware-based adaptive optics systems is a deformable mirror. There is quite a large number of such mirrors based on different principles and exhibiting varying performance. They constitute a significant portion of the cost of the final optical devices. In this study, we consider the possibility of replacing an adaptive mirror with the adaptive amplitude Fresnel zone plate, implemented using a digital light-processing matrix. Since such matrices are widely used in mass industry products (light projectors), their costs in large batches are 1–2 orders of magnitude lower than the cost of inexpensive deformable mirrors. Numerical modeling for scanning an optical coherence tomography system with adaptive optics is presented. It is shown that wavefront distortions with high spatial frequencies and large amplitudes can be corrected using an amplitude Fresnel zone plate. The results are compared with piezoelectric and microelectromechanical system mirrors.
Collapse
|
38
|
Iyer RR, Sorrells JE, Yang L, Chaney EJ, Spillman DR, Tibble BE, Renteria CA, Tu H, Žurauskas M, Marjanovic M, Boppart SA. Label-free metabolic and structural profiling of dynamic biological samples using multimodal optical microscopy with sensorless adaptive optics. Sci Rep 2022; 12:3438. [PMID: 35236862 PMCID: PMC8891278 DOI: 10.1038/s41598-022-06926-w] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Accepted: 02/01/2022] [Indexed: 01/21/2023] Open
Abstract
Label-free optical microscopy has matured as a noninvasive tool for biological imaging; yet, it is criticized for its lack of specificity, slow acquisition and processing times, and weak and noisy optical signals that lead to inaccuracies in quantification. We introduce FOCALS (Fast Optical Coherence, Autofluorescence Lifetime imaging, and Second harmonic generation) microscopy capable of generating NAD(P)H fluorescence lifetime, second harmonic generation (SHG), and polarization-sensitive optical coherence microscopy (OCM) images simultaneously. Multimodal imaging generates quantitative metabolic and morphological profiles of biological samples in vitro, ex vivo, and in vivo. Fast analog detection of fluorescence lifetime and real-time processing on a graphical processing unit enables longitudinal imaging of biological dynamics. We detail the effect of optical aberrations on the accuracy of FLIM beyond the context of undistorting image features. To compensate for the sample-induced aberrations, we implemented a closed-loop single-shot sensorless adaptive optics solution, which uses computational adaptive optics of OCM for wavefront estimation within 2 s and improves the quality of quantitative fluorescence imaging in thick tissues. Multimodal imaging with complementary contrasts improves the specificity and enables multidimensional quantification of the optical signatures in vitro, ex vivo, and in vivo, fast acquisition and real-time processing improve imaging speed by 4-40 × while maintaining enough signal for quantitative nonlinear microscopy, and adaptive optics improves the overall versatility, which enable FOCALS microscopy to overcome the limits of traditional label-free imaging techniques.
Collapse
Affiliation(s)
- Rishyashring R. Iyer
- grid.35403.310000 0004 1936 9991Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, USA ,grid.35403.310000 0004 1936 9991Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, USA
| | - Janet E. Sorrells
- grid.35403.310000 0004 1936 9991Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, USA ,grid.35403.310000 0004 1936 9991Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, USA
| | - Lingxiao Yang
- grid.35403.310000 0004 1936 9991Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, USA ,grid.35403.310000 0004 1936 9991Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, USA
| | - Eric J. Chaney
- grid.35403.310000 0004 1936 9991Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, USA
| | - Darold R. Spillman
- grid.35403.310000 0004 1936 9991Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, USA
| | - Brian E. Tibble
- grid.35403.310000 0004 1936 9991Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, USA ,grid.35403.310000 0004 1936 9991The School of Molecular and Cellular Biology, University of Illinois at Urbana-Champaign, Urbana, USA
| | - Carlos A. Renteria
- grid.35403.310000 0004 1936 9991Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, USA ,grid.35403.310000 0004 1936 9991Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, USA
| | - Haohua Tu
- grid.35403.310000 0004 1936 9991Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, USA ,grid.35403.310000 0004 1936 9991Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, USA
| | - Mantas Žurauskas
- grid.35403.310000 0004 1936 9991Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, USA
| | - Marina Marjanovic
- grid.35403.310000 0004 1936 9991Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, USA ,grid.35403.310000 0004 1936 9991Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, USA ,grid.35403.310000 0004 1936 9991Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, Urbana, USA
| | - Stephen A. Boppart
- grid.35403.310000 0004 1936 9991Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, USA ,grid.35403.310000 0004 1936 9991Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, USA ,grid.35403.310000 0004 1936 9991Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, USA ,grid.35403.310000 0004 1936 9991Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, Urbana, USA ,grid.35403.310000 0004 1936 9991Cancer Center at Illinois, University of Illinois at Urbana-Champaign, Urbana, USA
| |
Collapse
|
39
|
Tamura M, Moriguchi Y, Yeh SY, Matsumoto A, Shibutani M, Asao T, Mino T, Nakanishi M, Kubota A, Akiba M. Sensorless astigmatism correction using a variable cross-cylinder for high lateral resolution optical coherence tomography in a human retina. APPLIED OPTICS 2021; 60:9553-9559. [PMID: 34807099 DOI: 10.1364/ao.441646] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Accepted: 09/30/2021] [Indexed: 06/13/2023]
Abstract
High lateral resolution (∼5µm) optical coherence tomography (OCT) that employs a variable cross-cylinder (VCC) to compensate for astigmatism is presented for visualizing minute structures of the human retina. The VCC and its sensorless optimization process enable ocular astigmatism correction of up to -5.0 diopter within a few seconds. VCC correction has been proven to increase the signal-to-noise ratio and lateral resolution using a model eye. This process is also validated using the human eye by visualizing the capillary network and human cone mosaic. The proposed method is applicable to existing OCT, making high lateral resolution OCT practical in clinical settings.
Collapse
|
40
|
Datlinger F, Wassermann L, Reumueller A, Hajdu D, Steiner I, Salas M, Drexler W, Pircher M, Schmidt-Erfurth U, Pollreisz A. Assessment of Detailed Photoreceptor Structure and Retinal Sensitivity in Diabetic Macular Ischemia Using Adaptive Optics-OCT and Microperimetry. Invest Ophthalmol Vis Sci 2021; 62:1. [PMID: 34605880 PMCID: PMC8496411 DOI: 10.1167/iovs.62.13.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose The purpose of this study was to assess density and morphology of cone photoreceptors (PRs) and corresponding retinal sensitivity in ischemic compared to nonischemic retinal capillary areas of diabetic eyes using adaptive optics optical coherence tomography (AO-OCT) and microperimetry (MP). Methods In this cross-sectional, observational study five eyes of four patients (2 eyes with proliferative diabetic retinopathy (DR) and 3 eyes moderate nonproliferative DR) were included. PR morphology and density was manually assessed in AO-OCT en face images both at the axial position of the inner-segment outer segment (IS/OS) and cone outer segment tips (COSTs). Retinal sensitivity was determined by fundus-controlled microperimetry in corresponding areas (MP-3, Nidek). Results In AO-OCT, areas affected by capillary nonperfusion showed severe alterations of cone PR morphology at IS/OS and COST compared to areas with intact capillary perfusion (84% and 87% vs. 9% and 8% of area affected for IS/OS and COST, respectively). Mean reduction of PR signal density in affected areas compared to those with intact superficial capillary plexus (SCP) and deep capillary plexus (DCP) perfusion of similar eccentricity was -38% at the level of IS/OS (P = 0.01) and -39% at the level of COST (P = 0.01). Mean retinal sensitivity was 10.8 ± 5.4 in areas affected by DCP nonperfusion and 28.2 ± 1.5 outside these areas (P < 0.001). Conclusions Cone PR morphology and signal density are severely altered in areas of capillary nonperfusion. These structural changes are accompanied by a severe reduction of retinal sensitivity, indicating the importance of preventing impaired capillary circulation in patients with DR.
Collapse
Affiliation(s)
- Felix Datlinger
- Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| | - Lorenz Wassermann
- Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| | - Adrian Reumueller
- Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| | - Dorottya Hajdu
- Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| | - Irene Steiner
- Center of Medical Statistics, Informatics and Intelligent Systems, Medical University of Vienna, Vienna, Austria
| | - Matthias Salas
- Center of Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Wolfgang Drexler
- Center of Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Michael Pircher
- Center of Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Ursula Schmidt-Erfurth
- Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| | - Andreas Pollreisz
- Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
41
|
Brunner E, Shatokhina J, Shirazi MF, Drexler W, Leitgeb R, Pollreisz A, Hitzenberger CK, Ramlau R, Pircher M. Retinal adaptive optics imaging with a pyramid wavefront sensor. BIOMEDICAL OPTICS EXPRESS 2021; 12:5969-5990. [PMID: 34745716 PMCID: PMC8548025 DOI: 10.1364/boe.438915] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Accepted: 08/04/2021] [Indexed: 05/25/2023]
Abstract
The pyramid wavefront sensor (P-WFS) has replaced the Shack-Hartmann (SH-) WFS as the sensor of choice for high-performance adaptive optics (AO) systems in astronomy. Many advantages of the P-WFS, such as its adjustable pupil sampling and superior sensitivity, are potentially of great benefit for AO-supported imaging in ophthalmology as well. However, so far no high quality ophthalmic AO imaging was achieved using this novel sensor. Usually, a P-WFS requires modulation and high precision optics that lead to high complexity and costs of the sensor. These factors limit the competitiveness of the P-WFS with respect to other WFS devices for AO correction in visual science. Here, we present a cost-effective realization of AO correction with a non-modulated P-WFS based on standard components and apply this technique to human retinal in vivo imaging using optical coherence tomography (OCT). P-WFS based high quality AO imaging was successfully performed in 5 healthy subjects and smallest retinal cells such as central foveal cone photoreceptors are visualized. The robustness and versatility of the sensor is demonstrated in the model eye under various conditions and in vivo by high-resolution imaging of other structures in the retina using standard and extended fields of view. As a quality benchmark, the performance of conventional SH-WFS based AO was used and successfully met. This work may trigger a paradigm shift with respect to the wavefront sensor of choice for AO in ophthalmic imaging.
Collapse
Affiliation(s)
- Elisabeth Brunner
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria
| | - Julia Shatokhina
- Johann Radon Institute for Computational and Applied Mathematics, Altenbergerstrasse 69, A-4040 Linz, Austria
| | - Muhammad Faizan Shirazi
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria
| | - Wolfgang Drexler
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria
| | - Rainer Leitgeb
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria
| | - Andreas Pollreisz
- Department of Ophthalmology and Optometry, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria
| | - Christoph K. Hitzenberger
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria
| | - Ronny Ramlau
- Johann Radon Institute for Computational and Applied Mathematics, Altenbergerstrasse 69, A-4040 Linz, Austria
- Johannes Kepler University Linz, Industrial Mathematics Institute, Altenbergerstrasse 69, A-4040 Linz, Austria
| | - Michael Pircher
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria
| |
Collapse
|
42
|
Valente D, Vienola KV, Zawadzki RJ, Jonnal RS. Simultaneous directional full-field OCT using path-length and carrier multiplexing. OPTICS EXPRESS 2021; 29:32179-32195. [PMID: 34615295 PMCID: PMC8687100 DOI: 10.1364/oe.435761] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2021] [Revised: 09/02/2021] [Accepted: 09/07/2021] [Indexed: 06/13/2023]
Abstract
Full-field swept-source optical coherence tomography (FF-SS-OCT) is an emerging technology with potential applications in ophthalmic imaging, microscopy, metrology, and other domains. Here we demonstrate a novel method of multiplexing FF-SS-OCT signals using carrier modulation (CM). The principle of CM could be used to inspect various properties of the scattered light, e.g. its spectrum, polarization, Doppler shift, or distribution in the pupil. The last of these will be explored in this work, where CM was used to acquire images passing through two different optical pupils. The two pupils contained semicircular optical windows with perpendicular orientations, with each window permitting measurement of scattering anisotropy in one dimension by inducing an optical delay between the images formed by the two halves of the pupil. Together, the two forms of multiplexing permit measurement of differential scattering anisotropy in the x and y dimensions simultaneously. To demonstrate the feasibility of this technique our carrier multiplexed directional FF-OCT (CM-D-FF-OCT) system was used to acquire images of a microlens array, human hair, onion skin and in vivo human retina. The results of these studies are presented and briefly discussed in the context of future development and application of this technique.
Collapse
Affiliation(s)
- Denise Valente
- Vision Science and Advanced Retinal Imaging Laboratory (VSRI), Department of Ophthalmology and Vision Science, University of California Davis, Sacramento, CA 95817, USA
| | - Kari V. Vienola
- Vision Science and Advanced Retinal Imaging Laboratory (VSRI), Department of Ophthalmology and Vision Science, University of California Davis, Sacramento, CA 95817, USA
| | - Robert J. Zawadzki
- Vision Science and Advanced Retinal Imaging Laboratory (VSRI), Department of Ophthalmology and Vision Science, University of California Davis, Sacramento, CA 95817, USA
- EyePod Small Animal Ocular Imaging Laboratory, Department of Cell Biology and Human Anatomy, University of California Davis, Davis, CA 95616, USA
| | - Ravi S. Jonnal
- Vision Science and Advanced Retinal Imaging Laboratory (VSRI), Department of Ophthalmology and Vision Science, University of California Davis, Sacramento, CA 95817, USA
| |
Collapse
|
43
|
Pandiyan VP, Jiang X, Kuchenbecker JA, Sabesan R. Reflective mirror-based line-scan adaptive optics OCT for imaging retinal structure and function. BIOMEDICAL OPTICS EXPRESS 2021; 12:5865-5880. [PMID: 34692221 PMCID: PMC8515964 DOI: 10.1364/boe.436337] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/08/2021] [Revised: 08/16/2021] [Accepted: 08/20/2021] [Indexed: 05/06/2023]
Abstract
Line-scan OCT incorporated with adaptive optics (AO) offers high resolution, speed, and sensitivity for imaging retinal structure and function in vivo. Here, we introduce its implementation with reflective mirror-based afocal telescopes, optimized for imaging light-induced retinal activity (optoretinography) and weak retinal reflections at the cellular scale. A non-planar optical design was followed based on previous recommendations with key differences specific to a line-scan geometry. The three beam paths fundamental to an OCT system -illumination/sample, detection, and reference- were modeled in Zemax optical design software to yield theoretically diffraction-limited performance over a 2.2 deg. field-of-view and 1.5 D vergence range at the eye's pupil. The performance for imaging retinal structure was exemplified by cellular-scale visualization of retinal ganglion cells, macrophages, foveal cones, and rods in human observers. The performance for functional imaging was exemplified by resolving the light-evoked optical changes in foveal cone photoreceptors where the spatial resolution was sufficient for cone spectral classification at an eccentricity 0.3 deg. from the foveal center. This enabled the first in vivo demonstration of reduced S-cone (short-wavelength cone) density in the human foveola, thus far observed only in ex vivo histological preparations. Together, the feasibility for high resolution imaging of retinal structure and function demonstrated here holds significant potential for basic science and translational applications.
Collapse
Affiliation(s)
- Vimal Prabhu Pandiyan
- Department of Ophthalmology, University of Washington School of Medicine, Seattle, WA 98109, USA
- Co-first authors with equal contribution
| | - Xiaoyun Jiang
- Department of Ophthalmology, University of Washington School of Medicine, Seattle, WA 98109, USA
- Co-first authors with equal contribution
| | - James A Kuchenbecker
- Department of Ophthalmology, University of Washington School of Medicine, Seattle, WA 98109, USA
| | - Ramkumar Sabesan
- Department of Ophthalmology, University of Washington School of Medicine, Seattle, WA 98109, USA
| |
Collapse
|
44
|
Kawai K, Uji A, Murakami T, Kadomoto S, Oritani Y, Dodo Y, Muraoka Y, Akagi T, Miyata M, Tsujikawa A. IMAGE EVALUATION OF ARTIFICIAL INTELLIGENCE-SUPPORTED OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY IMAGING USING OCT-A1 DEVICE IN DIABETIC RETINOPATHY. Retina 2021; 41:1730-1738. [PMID: 33395219 DOI: 10.1097/iae.0000000000003101] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
PURPOSE To investigate the effect of denoise processing by artificial intelligence (AI) on the optical coherence tomography angiography (OCTA) images in eyes with retinal lesions. METHODS Prospective, observational, cross-sectional study. Optical coherence tomography angiography imaging of a 3 × 3-mm area involving the lesions (neovascularization, intraretinal microvascular abnormality, and nonperfusion area) was performed five times using OCT-HS100 (Canon, Tokyo, Japan). We acquired AI-denoised OCTA images and averaging OCTA images generated from five cube scan data through built-in software. Main outcomes were image acquisition time and the subjective assessment by graders and quantitative measurements of original OCTA images, averaging OCTA images, and AI-denoised OCTA images. The parameters of quantitative measurements were contrast-to-noise ratio, vessel density, vessel length density, and fractal dimension. RESULTS We studied 56 eyes from 43 patients. The image acquisition times for the original, averaging, and AI-denoised images were 31.87 ± 12.02, 165.34 ± 41.91, and 34.37 ± 12.02 seconds, respectively. We found significant differences in vessel density, vessel length density, fractal dimension, and contrast-to-noise ratio (P < 0.001) between original, averaging, and AI-denoised images. Both subjective and quantitative evaluations showed that AI-denoised OCTA images had less background noise and depicted vessels clearly. In AI-denoised images, the presence of fictional vessels was suspected in 2 of the 35 cases of nonperfusion area. CONCLUSION Denoise processing by AI improved the image quality of OCTA in a shorter time and allowed more accurate quantitative evaluation.
Collapse
Affiliation(s)
- Kentaro Kawai
- Department of Ophthalmology and Visual Sciences, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | | | | | | | | | | | | | | | | | | |
Collapse
|
45
|
Jonnal RS. Toward a clinical optoretinogram: a review of noninvasive, optical tests of retinal neural function. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:1270. [PMID: 34532407 PMCID: PMC8421939 DOI: 10.21037/atm-20-6440] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Accepted: 07/12/2021] [Indexed: 11/17/2022]
Abstract
The past few years have witnessed rapid development of the optoretinogram-a noninvasive, optical measurement of neural function in the retina, and especially the photoreceptors (Ph). While its recent development has been rapid, it represents the culmination of hundreds of experiments spanning decades. Early work showed measurable and reproducible changes in the optical properties of retinal explants and suspensions of Ph, and uncovered some of the biophysical and biochemical mechanisms underlying them. That work thus provided critical motivation for more recent work based on clinical imaging platforms, whose eventual goal is the improvement of ophthalmic care and streamlining the discovery of novel therapeutics. The first part of this review consists of a selective summary of the early work, and identifies four kinds of stimulus-evoked optical signals that have emerged from it: changes in light scattered from the membranous discs of the Ph's outer segment (OS), changes in light scattered by the front and back boundaries of the OS, rearrangement of scattering material in and near the OS, and changes in the OS length. In the past decade, all four of these signals have continued to be investigated using imaging systems already used in the clinic or intended for clinical and translational use. The second part of this review discusses these imaging modalities, their potential to detect and quantify the signals of interest, and other factors influencing their translational promise. Particular attention is paid to phase-sensitive optical coherence tomography (OCT) with adaptive optics (AO), a method in which both the amplitude and the phase of light reflected from individual Ph is monitored as visible stimuli are delivered to them. The record of the light's phase is decoded to reveal a reproducible pattern of deformation in the OS, while the amplitude reveals changes in scattering and structural rearrangements. The method has been demonstrated in a few labs and has been used to measure responses from both rods and cones. With the ability to detect responses to stimuli isomerizing less than 0.01% of photopigment, this technique may prove to be a quick, noninvasive, and objective way to measure subtle disease-related dysfunction at the cellular level, and thus to provide an entirely new and complementary biomarker for retinal disease and recovery.
Collapse
|
46
|
Park J, Brady DJ, Zheng G, Tian L, Gao L. Review of bio-optical imaging systems with a high space-bandwidth product. ADVANCED PHOTONICS 2021; 3:044001. [PMID: 35178513 PMCID: PMC8849623 DOI: 10.1117/1.ap.3.4.044001] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Optical imaging has served as a primary method to collect information about biosystems across scales-from functionalities of tissues to morphological structures of cells and even at biomolecular levels. However, to adequately characterize a complex biosystem, an imaging system with a number of resolvable points, referred to as a space-bandwidth product (SBP), in excess of one billion is typically needed. Since a gigapixel-scale far exceeds the capacity of current optical imagers, compromises must be made to obtain either a low spatial resolution or a narrow field-of-view (FOV). The problem originates from constituent refractive optics-the larger the aperture, the more challenging the correction of lens aberrations. Therefore, it is impractical for a conventional optical imaging system to achieve an SBP over hundreds of millions. To address this unmet need, a variety of high-SBP imagers have emerged over the past decade, enabling an unprecedented resolution and FOV beyond the limit of conventional optics. We provide a comprehensive survey of high-SBP imaging techniques, exploring their underlying principles and applications in bioimaging.
Collapse
Affiliation(s)
- Jongchan Park
- University of California, Department of Bioengineering, Los Angeles, California, United States
| | - David J. Brady
- University of Arizona, James C. Wyant College of Optical Sciences, Tucson, Arizona, United States
| | - Guoan Zheng
- University of Connecticut, Department of Biomedical Engineering, Storrs, Connecticut, United States
- University of Connecticut, Department of Electrical and Computer Engineering, Storrs, Connecticut, United States
| | - Lei Tian
- Boston University, Department of Electrical and Computer Engineering, Boston, Massachusetts, United States
| | - Liang Gao
- University of California, Department of Bioengineering, Los Angeles, California, United States
| |
Collapse
|
47
|
Song G, Jelly ET, Chu KK, Kendall WY, Wax A. A review of low-cost and portable optical coherence tomography. PROGRESS IN BIOMEDICAL ENGINEERING (BRISTOL, ENGLAND) 2021; 3:032002. [PMID: 37645660 PMCID: PMC10465117 DOI: 10.1088/2516-1091/abfeb7] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/31/2023]
Abstract
Optical coherence tomography (OCT) is a powerful optical imaging technique capable of visualizing the internal structure of biological tissues at near cellular resolution. For years, OCT has been regarded as the standard of care in ophthalmology, acting as an invaluable tool for the assessment of retinal pathology. However, the costly nature of most current commercial OCT systems has limited its general accessibility, especially in low-resource environments. It is therefore timely to review the development of low-cost OCT systems as a route for applying this technology to population-scale disease screening. Low-cost, portable and easy to use OCT systems will be essential to facilitate widespread use at point of care settings while ensuring that they offer the necessary imaging performances needed for clinical detection of retinal pathology. The development of low-cost OCT also offers the potential to enable application in fields outside ophthalmology by lowering the barrier to entry. In this paper, we review the current development and applications of low-cost, portable and handheld OCT in both translational and research settings. Design and cost-reduction techniques are described for general low-cost OCT systems, including considerations regarding spectrometer-based detection, scanning optics, system control, signal processing, and the role of 3D printing technology. Lastly, a review of clinical applications enabled by low-cost OCT is presented, along with a detailed discussion of current limitations and outlook.
Collapse
Affiliation(s)
- Ge Song
- Author to whom any correspondence should be addressed.
| | | | - Kengyeh K Chu
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, United States of America
| | - Wesley Y Kendall
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, United States of America
| | - Adam Wax
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, United States of America
| |
Collapse
|
48
|
Yao X, Tan B, Ho Y, Liu X, Wong D, Chua J, Wong TT, Perera S, Ang M, Werkmeister RM, Schmetterer L. Full circumferential morphological analysis of Schlemm's canal in human eyes using megahertz swept source OCT. BIOMEDICAL OPTICS EXPRESS 2021; 12:3865-3877. [PMID: 34457385 PMCID: PMC8367246 DOI: 10.1364/boe.426218] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Revised: 05/03/2021] [Accepted: 05/05/2021] [Indexed: 05/16/2023]
Abstract
We performed full circumferential imaging of the Schlemm's canal (SC) of two human eyes using a Fourier domain mode-lock laser (FDML) based 1.66-MHz SS-OCT prototype at 1060 nm. Eight volumes with overlapping margins were acquired around the limbal area with customized raster scanning patterns designed to fully cover the SC while minimizing motion artifacts. The SC was segmented from the volumes using a semi-automated active contour segmentation algorithm, whose mean dice similarity coefficient was 0.76 compared to the manual segmentation results. We also reconstructed three-dimensional (3D) renderings of the 360° SC by stitching the segmented SCs from the volumetric datasets. Quantitative metrics of the full circumferential SC were provided, including the mean and standard deviation (SD) of the cross-sectional area (CSA), the maximum CSA, the minimum and maximum SC opening width, and the number of collector channels (CC) stemming from the SC.
Collapse
Affiliation(s)
- Xinwen Yao
- SERI-NTU Advanced Ocular Engineering (STANCE), Singapore
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
| | - Bingyao Tan
- SERI-NTU Advanced Ocular Engineering (STANCE), Singapore
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
| | - Yijie Ho
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| | - Xinyu Liu
- SERI-NTU Advanced Ocular Engineering (STANCE), Singapore
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
| | - Damon Wong
- SERI-NTU Advanced Ocular Engineering (STANCE), Singapore
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
| | - Jacqueline Chua
- SERI-NTU Advanced Ocular Engineering (STANCE), Singapore
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore
| | - Tina T. Wong
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore
| | - Shamira Perera
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore
| | - Marcus Ang
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore
| | - René M. Werkmeister
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
| | - Leopold Schmetterer
- SERI-NTU Advanced Ocular Engineering (STANCE), Singapore
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
- Institute of Molecular and Clinical Ophthalmology, Basel, Switzerland
| |
Collapse
|
49
|
Konstantinou EK, Mendonça LSM, Braun P, Monahan KM, Mehta N, Gendelman I, Levine ES, Baumal CR, Witkin AJ, Duker JS, Waheed NK. Retinal Imaging Using a Confocal Scanning Laser Ophthalmoscope-Based High-Magnification Module. Ophthalmol Retina 2021; 5:438-449. [PMID: 32861857 DOI: 10.1016/j.oret.2020.08.014] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 08/19/2020] [Accepted: 08/19/2020] [Indexed: 06/11/2023]
Abstract
PURPOSE To evaluate the usefulness of a high-magnification module (HMM) lens to visualize retinal photoreceptors, retinal nerve fiber layer (RNFL), and superficial retinal vasculature in physiologic and pathologic retinal conditions. DESIGN Observational descriptive study. PARTICIPANTS Thirty-two participants with normal and pathologic retina examination results. METHODS Normal and pathologic maculae were imaged in vivo using still and video HMM lens modes, with fixation and contrast adjustments to enhance visualization. The HMM images were classified qualitatively based on structures identified as either good (photoreceptors seen), average (photoreceptor mosaic cannot be visualized clearly, retinal vessels and other retinal changes can be seen), or poor (no identifiable structures). Selected eyes were imaged with fundus photography, OCT, OCT angiography, indocyanine green angiography, and fluorescein angiography for comparison with the pathologic maculae. MAIN OUTCOMES MEASURES Description of HMM module-obtained macula images. RESULTS From 32 eyes imaged (16 normal and 16 pathologic retinas), 12 of 16 normal and 11 of 16 pathologic retinas demonstrated at least average image quality, in which retinal vasculature and landmarks could be visualized. The mosaic pattern of hexagonal shapes representing photoreceptors could not be resolved in most pathologic retinas. For the retinas in which the photoreceptor mosaics were visualized (12 of 16 normal and 2 of 16 pathologic retinas), parafoveal mosaic patterns appeared denser with better image quality for all participants compared with foveal photoreceptors. Difficulty in resolving the photoreceptors in the umbo, fovea, and perifovea was encountered, similar to what has been reported with adaptive optics devices. The RNFL was seen as arcuate hyperreflective bundles. Flow was observed in the macular microvasculature. Poorly resolved photoreceptors and scattered hyperreflective foci were correlated with changes in the retinal pigment epithelium in eyes with age-related macular degeneration or central serous chorioretinopathy. Macular striae were seen in eyes with epiretinal membrane. CONCLUSIONS In most eyes, regardless of whether retinal pathologic features were present, it was challenging to obtain average quality (or better) images. In the few participants with good-quality imaging, the parafoveal photoreceptor mosaic, vascular flow, and various features of pathologic eyes could be visualized.
Collapse
Affiliation(s)
- Eleni K Konstantinou
- New England Eye Center, Tufts University School of Medicine, Boston, Massachusetts
| | - Luísa S M Mendonça
- New England Eye Center, Tufts University School of Medicine, Boston, Massachusetts; Department of Ophthalmology, Federal University of São Paulo, São Paulo, Brazil
| | - Phillip Braun
- New England Eye Center, Tufts University School of Medicine, Boston, Massachusetts; Yale University School of Medicine, New Haven, Connecticut
| | - Kyle M Monahan
- Data Lab, Tufts Technology Services, Tufts University, Medford, Massachusetts
| | - Nihaal Mehta
- New England Eye Center, Tufts University School of Medicine, Boston, Massachusetts; Warren Alpert Medical School of Brown University, Providence, Rhode Island
| | - Isaac Gendelman
- New England Eye Center, Tufts University School of Medicine, Boston, Massachusetts
| | - Emily S Levine
- New England Eye Center, Tufts University School of Medicine, Boston, Massachusetts
| | - Caroline R Baumal
- New England Eye Center, Tufts University School of Medicine, Boston, Massachusetts
| | - Andre J Witkin
- New England Eye Center, Tufts University School of Medicine, Boston, Massachusetts
| | - Jay S Duker
- New England Eye Center, Tufts University School of Medicine, Boston, Massachusetts
| | - Nadia K Waheed
- New England Eye Center, Tufts University School of Medicine, Boston, Massachusetts.
| |
Collapse
|
50
|
Ringel MJ, Tang EM, Tao YK. Advances in multimodal imaging in ophthalmology. Ther Adv Ophthalmol 2021; 13:25158414211002400. [PMID: 35187398 PMCID: PMC8855415 DOI: 10.1177/25158414211002400] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Accepted: 02/23/2021] [Indexed: 12/12/2022] Open
Abstract
Multimodality ophthalmic imaging systems aim to enhance the contrast, resolution, and functionality of existing technologies to improve disease diagnostics and therapeutic guidance. These systems include advanced acquisition and post-processing methods using optical coherence tomography (OCT), combined scanning laser ophthalmoscopy and OCT systems, adaptive optics, surgical guidance, and photoacoustic technologies. Here, we provide an overview of these ophthalmic imaging systems and their clinical and basic science applications.
Collapse
Affiliation(s)
- Morgan J. Ringel
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Eric M. Tang
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Yuankai K. Tao
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37235, USA
| |
Collapse
|