Lago MA, Abbey CK, Eckstein MP. Medical image quality metrics for foveated model observers. J Med Imaging (Bellingham) 2021; 8:041209. [PMID: 34423070 DOI: 10.1117/1.jmi.8.4.041209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Accepted: 07/20/2021] [Indexed: 11/14/2022] Open
Abstract
Purpose: A recently proposed model observer mimics the foveated nature of the human visual system by processing the entire image with varying spatial detail, executing eye movements, and scrolling through slices. The model can predict how human search performance changes with signal type and modality (2D versus 3D), yet its implementation is computationally expensive and time-consuming. Here, we evaluate various image quality metrics using extensions of the classic index of detectability expression and assess foveated model observers for search tasks. Approach: We evaluated foveated extensions of a channelized Hotelling and nonprewhitening matched filter model with an eye filter. The proposed methods involve calculating a model index of detectability ( d ' ) for each retinal eccentricity and combining these with a weighting function into a single detectability metric. We assessed different versions of the weighting function that varied in the required measurements of the human observers' search (no measurements, eye movement patterns, size of the image, and median search times). Results: We show that the index of detectability across eccentricities weighted using the eye movement patterns of observers best predicted human performance in 2D versus 3D search performance for a small microcalcification-like signal and a larger mass-like. The metric with a weighting function based on median search times was the second best predicting human results. Conclusions: The findings provide a set of model observer tools to evaluate image quality in the early stages of imaging system evaluation or design without implementing the more computationally complex foveated search model.
Collapse
Affiliation(s)
- Miguel A Lago
- University of California at Santa Barbara, Department of Psychological and Brain Sciences, Santa Barbara, California, United States
| | - Craig K Abbey
- University of California at Santa Barbara, Department of Psychological and Brain Sciences, Santa Barbara, California, United States
| | - Miguel P Eckstein
- University of California at Santa Barbara, Department of Psychological and Brain Sciences, Santa Barbara, California, United States.,University of California at Santa Barbara, Department of Electrical and Computer Engineering, Santa Barbara, California, United States
| |
Collapse
|
2
|
Lago MA, Abbey CK, Eckstein MP. Foveated Model Observers for Visual Search in 3D Medical Images. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:1021-1031. [PMID: 33315556 PMCID: PMC7994931 DOI: 10.1109/tmi.2020.3044530] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Model observers have a long history of success in predicting human observer performance in clinically-relevant detection tasks. New 3D image modalities provide more signal information but vastly increase the search space to be scrutinized. Here, we compared standard linear model observers (ideal observers, non-pre-whitening matched filter with eye filter, and various versions of Channelized Hotelling models) to human performance searching in 3D 1/f2.8 filtered noise images and assessed its relationship to the more traditional location known exactly detection tasks and 2D search. We investigated two different signal types that vary in their detectability away from the point of fixation (visual periphery). We show that the influence of 3D search on human performance interacts with the signal's detectability in the visual periphery. Detection performance for signals difficult to detect in the visual periphery deteriorates greatly in 3D search but not in 3D location known exactly and 2D search. Standard model observers do not predict the interaction between 3D search and signal type. A proposed extension of the Channelized Hotelling model (foveated search model) that processes the image with reduced spatial detail away from the point of fixation, explores the image through eye movements, and scrolls across slices can successfully predict the interaction observed in humans and also the types of errors in 3D search. Together, the findings highlight the need for foveated model observers for image quality evaluation with 3D search.
Collapse
|
3
|
Zeng R, Samuelson FW, Sharma D, Badal A, Christian GG, Glick SJ, Myers KJ, Badano A. Computational reader design and statistical performance evaluation of an in-silico imaging clinical trial comparing digital breast tomosynthesis with full-field digital mammography. J Med Imaging (Bellingham) 2020; 7:042802. [PMID: 32118094 PMCID: PMC7043285 DOI: 10.1117/1.jmi.7.4.042802] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2019] [Accepted: 01/07/2020] [Indexed: 01/15/2023] Open
Abstract
A recent study reported on an in-silico imaging trial that evaluated the performance of digital breast tomosynthesis (DBT) as a replacement for full-field digital mammography (FFDM) for breast cancer screening. In this in-silico trial, the whole imaging chain was simulated, including the breast phantom generation, the x-ray transport process, and computational readers for image interpretation. We focus on the design and performance characteristics of the computational reader in the above-mentioned trial. Location-known lesion (spiculated mass and clustered microcalcifications) detection tasks were used to evaluate the imaging system performance. The computational readers were designed based on the mechanism of a channelized Hotelling observer (CHO), and the reader models were selected to trend human performance. Parameters were tuned to ensure stable lesion detectability. A convolutional CHO that can adapt a round channel function to irregular lesion shapes was compared with the original CHO and was found to be suitable for detecting clustered microcalcifications but was less optimal in detecting spiculated masses. A three-dimensional CHO that operated on the multiple slices was compared with a two-dimensional (2-D) CHO that operated on three versions of 2-D slabs converted from the multiple slices and was found to be optimal in detecting lesions in DBT. Multireader multicase reader output analysis was used to analyze the performance difference between FFDM and DBT for various breast and lesion types. The results showed that DBT was more beneficial in detecting masses than detecting clustered microcalcifications compared with FFDM, consistent with the finding in a clinical imaging trial. Statistical uncertainty smaller than 0.01 standard error for the estimated performance differences was achieved with a dataset containing approximately 3000 breast phantoms. The computational reader design methodology presented provides evidence that model observers can be useful in-silico tools for supporting the performance comparison of breast imaging systems.
Collapse
Affiliation(s)
- Rongping Zeng
- Division of Imaging, Diagnostics and Software Reliability, Office of Science and Engineering Laboratories, CDRH, FDA, Silver Spring, Maryland, United States
| | - Frank W. Samuelson
- Division of Imaging, Diagnostics and Software Reliability, Office of Science and Engineering Laboratories, CDRH, FDA, Silver Spring, Maryland, United States
| | - Diksha Sharma
- Division of Imaging, Diagnostics and Software Reliability, Office of Science and Engineering Laboratories, CDRH, FDA, Silver Spring, Maryland, United States
| | - Andreu Badal
- Division of Imaging, Diagnostics and Software Reliability, Office of Science and Engineering Laboratories, CDRH, FDA, Silver Spring, Maryland, United States
| | - Graff G. Christian
- Division of Imaging, Diagnostics and Software Reliability, Office of Science and Engineering Laboratories, CDRH, FDA, Silver Spring, Maryland, United States
| | - Stephen J. Glick
- Division of Imaging, Diagnostics and Software Reliability, Office of Science and Engineering Laboratories, CDRH, FDA, Silver Spring, Maryland, United States
| | - Kyle J. Myers
- Division of Imaging, Diagnostics and Software Reliability, Office of Science and Engineering Laboratories, CDRH, FDA, Silver Spring, Maryland, United States
| | - Aldo Badano
- Division of Imaging, Diagnostics and Software Reliability, Office of Science and Engineering Laboratories, CDRH, FDA, Silver Spring, Maryland, United States
| |
Collapse
|
4
|
He X. The falsifiability of Swets' ROC may bring consensus to search performance assessment. Med Phys 2018; 45:493-495. [DOI: 10.1002/mp.12662] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2017] [Revised: 09/14/2017] [Accepted: 09/18/2017] [Indexed: 11/06/2022] Open
|
5
|
Eckstein MP, Lago MA, Abbey CK. The role of extra-foveal processing in 3D imaging. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2017; 10136. [PMID: 29176920 DOI: 10.1117/12.2255879] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
The field of medical image quality has relied on the assumption that metrics of image quality for simple visual detection tasks are a reliable proxy for the more clinically realistic visual search tasks. Rank order of signal detectability across conditions often generalizes from detection to search tasks. Here, we argue that search in 3D images represents a paradigm shift in medical imaging: radiologists typically cannot exhaustively scrutinize all regions of interest with the high acuity fovea requiring detection of signals with extra-foveal areas (visual periphery) of the human retina. We hypothesize that extra-foveal processing can alter the detectability of certain types of signals in medical images with important implications for search in 3D medical images. We compare visual search of two different types of signals in 2D vs. 3D images. We show that a small microcalcification-like signal is more highly detectable than a larger mass-like signal in 2D search, but its detectability largely decreases (relative to the larger signal) in the 3D search task. Utilizing measurements of observer detectability as a function retinal eccentricity and observer eye fixations we can predict the pattern of results in the 2D and 3D search studies. Our findings: 1) suggest that observer performance findings with 2D search might not always generalize to 3D search; 2) motivate the development of a new family of model observers that take into account the inhomogeneous visual processing across the retina (foveated model observers).
Collapse
Affiliation(s)
- Miguel P Eckstein
- Department of Psychological & Brain Sciences, University of California Santa Barbara, Santa Barbara, CA. 93106, USA
| | - Miguel A Lago
- Department of Psychological & Brain Sciences, University of California Santa Barbara, Santa Barbara, CA. 93106, USA
| | - Craig K Abbey
- Department of Psychological & Brain Sciences, University of California Santa Barbara, Santa Barbara, CA. 93106, USA
| |
Collapse
|