1
|
Brault D, Olivier T, Faure N, Dixneuf S, Kolytcheff C, Charmette E, Soulez F, Fournier C. Multispectral in-line hologram reconstruction with aberration compensation applied to Gram-stained bacteria microscopy. Sci Rep 2023; 13:14437. [PMID: 37660181 PMCID: PMC10475072 DOI: 10.1038/s41598-023-41079-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Accepted: 08/21/2023] [Indexed: 09/04/2023] Open
Abstract
In multispectral digital in-line holographic microscopy (DIHM), aberrations of the optical system affect the repeatability of the reconstruction of transmittance, phase and morphology of the objects of interest. Here we address this issue first by model fitting calibration using transparent beads inserted in the sample. This step estimates the aberrations of the optical system as a function of the lateral position in the field of view and at each wavelength. Second, we use a regularized inverse problem approach (IPA) to reconstruct the transmittance and phase of objects of interest. Our method accounts for shift-variant chromatic and geometrical aberrations in the forward model. The multi-wavelength holograms are jointly reconstructed by favouring the colocalization of the object edges. The method is applied to the case of bacteria imaging in Gram-stained blood smears. It shows our methodology evaluates aberrations with good repeatability. This improves the repeatability of the reconstructions and delivers more contrasted spectral signatures in transmittance and phase, which could benefit applications of microscopy, such as the analysis and classification of stained bacteria.
Collapse
Affiliation(s)
- Dylan Brault
- Université Jean Monnet Saint-Etienne, CNRS, Institut d Optique Graduate School, Laboratoire Hubert Curien UMR 5516, 42023, Saint-Etienne, France
| | - Thomas Olivier
- Université Jean Monnet Saint-Etienne, CNRS, Institut d Optique Graduate School, Laboratoire Hubert Curien UMR 5516, 42023, Saint-Etienne, France
| | - Nicolas Faure
- bioMérieux, Centre Christophe Mérieux, 38024, Grenoble, France
| | - Sophie Dixneuf
- BIOASTER, Bioassays, Microsystems and Optical Engineering Unit, Lyon, France
| | | | | | - Ferréol Soulez
- Univ. de Lyon, Université Lyon1, ENS de Lyon, CNRS, Centre de Recherche Astrophysique de Lyon, UMR 5574, 69230, Saint-Genis-Laval, France
| | - Corinne Fournier
- Université Jean Monnet Saint-Etienne, CNRS, Institut d Optique Graduate School, Laboratoire Hubert Curien UMR 5516, 42023, Saint-Etienne, France.
| |
Collapse
|
2
|
Wang Z, Bianco V, Maffettone PL, Ferraro P. Holographic flow scanning cytometry overcomes depth of focus limits and smartly adapts to microfluidic speed. LAB ON A CHIP 2023; 23:2316-2326. [PMID: 37074006 DOI: 10.1039/d3lc00063j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Space-time digital holography (STDH) maps holograms in a hybrid space-time domain to achieve extended field of view, resolution enhanced, quantitative phase-contrast microscopy and velocimetry of flowing objects in a label-free modality. In STDH, area sensors can be replaced by compact and faster linear sensor arrays to augment the imaging throughput and to compress data from a microfluidic video sequence into one single hybrid hologram. However, in order to ensure proper imaging, the velocity of the objects in microfluidic channels has to be well-matched to the acquisition frame rate, which is the major constraint of the method. Also, imaging all the flowing samples in focus at the same time, while avoiding hydrodynamic focusing devices, is a highly desirable goal. Here we demonstrate a novel processing pipeline that addresses non-ideal flow conditions and is capable of returning the correct and extended focus phase contrast mapping of an entire microfluidic experiment in a single image. We apply this novel processing strategy to recover phase imaging of flowing HeLa cells in a lab-on-a-chip platform even when severely undersampled due to too fast flow while ensuring that all cells are in focus.
Collapse
Affiliation(s)
- Zhe Wang
- Dipartimento di Ingegneria Chimica, dei Materiali e della Produzione Industriale, Università degli Studi di Napoli "Federico II", P.le Tecchio 80, 80125, Napoli, Italy
- Institute of Applied Sciences and Intelligent Systems "E. Caianiello" (ISASI-CNR), via Campi Flegrei 34, 80078 Pozzuoli, Napoli, Italy.
| | - Vittorio Bianco
- Institute of Applied Sciences and Intelligent Systems "E. Caianiello" (ISASI-CNR), via Campi Flegrei 34, 80078 Pozzuoli, Napoli, Italy.
| | - Pier Luca Maffettone
- Dipartimento di Ingegneria Chimica, dei Materiali e della Produzione Industriale, Università degli Studi di Napoli "Federico II", P.le Tecchio 80, 80125, Napoli, Italy
- Institute of Applied Sciences and Intelligent Systems "E. Caianiello" (ISASI-CNR), via Campi Flegrei 34, 80078 Pozzuoli, Napoli, Italy.
| | - Pietro Ferraro
- Institute of Applied Sciences and Intelligent Systems "E. Caianiello" (ISASI-CNR), via Campi Flegrei 34, 80078 Pozzuoli, Napoli, Italy.
| |
Collapse
|
3
|
Micó V, Rogalski M, Picazo-Bueno JÁ, Trusiak M. Single-shot wavelength-multiplexed phase microscopy under Gabor regime in a regular microscope embodiment. Sci Rep 2023; 13:4257. [PMID: 36918618 PMCID: PMC10015059 DOI: 10.1038/s41598-023-31300-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Accepted: 03/09/2023] [Indexed: 03/16/2023] Open
Abstract
Phase imaging microscopy under Gabor regime has been recently reported as an extremely simple, low cost and compact way to update a standard bright-field microscope with coherent sensing capabilities. By inserting coherent illumination in the microscope embodiment and producing a small defocus distance of the sample at the input plane, the digital sensor records an in-line Gabor hologram of the target sample, which is then numerically post-processed to finally achieve the sample's quantitative phase information. However, the retrieved phase distribution is affected by the two well-known drawbacks when dealing with Gabor's regime, that is, coherent noise and twin image disturbances. Here, we present a single-shot technique based on wavelength multiplexing for mitigating these two effects. A multi-illumination laser source (including 3 diode lasers) illuminates the sample and a color digital sensor (conventional RGB color camera) is used to record the wavelength-multiplexed Gabor hologram in a single exposure. The technique is completed by presenting a novel algorithm based on a modified Gerchberg-Saxton kernel to finally retrieve an enhanced quantitative phase image of the sample, enhanced in terms of coherent noise removal and twin image minimization. Experimental validations are performed in a regular Olympus BX-60 upright microscope using a 20X 0.46NA objective lens and considering static (resolution test targets) and dynamic (living spermatozoa) phase samples.
Collapse
Affiliation(s)
- Vicente Micó
- Departamento de Óptica y Optometría y Ciencias de la Visión, Universidad de Valencia, C/Doctor Moliner 50, 46100, Burjassot, Spain.
| | - Mikołaj Rogalski
- Institute of Micromechanics and Photonics, Warsaw University of Technology, 8 Sw. A. Boboli St., 02‑525, Warsaw, Poland
| | - José Ángel Picazo-Bueno
- Departamento de Óptica y Optometría y Ciencias de la Visión, Universidad de Valencia, C/Doctor Moliner 50, 46100, Burjassot, Spain
| | - Maciej Trusiak
- Institute of Micromechanics and Photonics, Warsaw University of Technology, 8 Sw. A. Boboli St., 02‑525, Warsaw, Poland
| |
Collapse
|
4
|
Picazo-Bueno JÁ, Sanz M, Granero L, García J, Micó V. Multi-Illumination Single-Holographic-Exposure Lensless Fresnel (MISHELF) Microscopy: Principles and Biomedical Applications. SENSORS (BASEL, SWITZERLAND) 2023; 23:1472. [PMID: 36772511 PMCID: PMC9918952 DOI: 10.3390/s23031472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/17/2022] [Revised: 01/13/2023] [Accepted: 01/19/2023] [Indexed: 06/18/2023]
Abstract
Lensless holographic microscopy (LHM) comes out as a promising label-free technique since it supplies high-quality imaging and adaptive magnification in a lens-free, compact and cost-effective way. Compact sizes and reduced prices of LHMs make them a perfect instrument for point-of-care diagnosis and increase their usability in limited-resource laboratories, remote areas, and poor countries. LHM can provide excellent intensity and phase imaging when the twin image is removed. In that sense, multi-illumination single-holographic-exposure lensless Fresnel (MISHELF) microscopy appears as a single-shot and phase-retrieved imaging technique employing multiple illumination/detection channels and a fast-iterative phase-retrieval algorithm. In this contribution, we review MISHELF microscopy through the description of the principles, the analysis of the performance, the presentation of the microscope prototypes and the inclusion of the main biomedical applications reported so far.
Collapse
Affiliation(s)
- José Ángel Picazo-Bueno
- Department of Optics, Optometry and Vision Science, University of Valencia, 46100 Burjassot, Spain
- Biomedical Technology Center of the Medical Faculty, University of Muenster, Mendelstr. 17, D-48149 Muenster, Germany
| | - Martín Sanz
- Department of Optics, Optometry and Vision Science, University of Valencia, 46100 Burjassot, Spain
| | - Luis Granero
- Department of Optics, Optometry and Vision Science, University of Valencia, 46100 Burjassot, Spain
| | - Javier García
- Department of Optics, Optometry and Vision Science, University of Valencia, 46100 Burjassot, Spain
| | - Vicente Micó
- Department of Optics, Optometry and Vision Science, University of Valencia, 46100 Burjassot, Spain
| |
Collapse
|
5
|
Liu Y, Liu Q, Zhao S, Sun W, Xu B, He Z, Zhang J. Single-exposure multi-wavelength diffraction imaging with blazed grating. OPTICS LETTERS 2022; 47:485-488. [PMID: 35103657 DOI: 10.1364/ol.440336] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/12/2021] [Accepted: 11/17/2021] [Indexed: 06/14/2023]
Abstract
Multi-wavelength diffraction imaging is a lensless, high-resolution imaging technology. To avoid multiple exposures and enable high-speed data collection, here an innovative setup for the single-exposure multi-wavelength diffraction imaging based on a blazed grating is proposed. Since the blazed angle varies with the wavelength, the diffraction patterns for the individual wavelengths can be separated from each other and recorded in a single measurement at one time. A method of high-precision position alignment between different wavelength patterns is proposed in our system to achieve good image quality and high resolution. Experiments on a phase-only USAF resolution target and biological samples were carried out to verify the effectiveness of our proposed method. This proposed setup has such advantages as a simpler structure, fast recording, and algorithm robustness.
Collapse
|
6
|
Loetgering L, Witte S, Rothhardt J. Advances in laboratory-scale ptychography using high harmonic sources [Invited]. OPTICS EXPRESS 2022; 30:4133-4164. [PMID: 35209658 DOI: 10.1364/oe.443622] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Accepted: 12/22/2021] [Indexed: 06/14/2023]
Abstract
Extreme ultraviolet microscopy and wavefront sensing are key elements for next-generation ultrafast applications, such as chemically-resolved imaging, focal spot diagnostics in pump-and-probe experiments, and actinic metrology for the state-of-the-art lithography node at 13.5 nm wavelength. Ptychography offers a robust solution to the aforementioned challenges. Originally adapted by the electron and synchrotron communities, advances in the stability and brightness of high-harmonic tabletop sources have enabled the transfer of ptychography to the laboratory. This review covers the state of the art in tabletop ptychography with high harmonic generation sources. We consider hardware options such as illumination optics and detector concepts as well as algorithmic aspects in the analysis of multispectral ptychography data. Finally, we review technological application cases such as multispectral wavefront sensing, attosecond pulse characterization, and depth-resolved imaging.
Collapse
|
7
|
Boonzajer Flaes D, Štolzová H, Čižmár T. Time-averaged image projection through a multimode fiber. OPTICS EXPRESS 2021; 29:28005-28020. [PMID: 34614941 DOI: 10.1364/oe.431842] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Accepted: 07/17/2021] [Indexed: 06/13/2023]
Abstract
Many disciplines, ranging from lithography to opto-genetics, require high-fidelity image projection. However, not all optical systems can display all types of images with equal ease. Therefore, the image projection quality is dependent on the type of image. In some circumstances, this can lead to a catastrophic loss of intensity or image quality. For complex optical systems, it may not be known in advance which types of images pose a problem. Here we show a new method called Time-Averaged image Projection (TAP), allowing us to mitigate these limitations by taking the entire image projection system into account despite its complexity and building the desired intensity distribution up from multiple illumination patterns. Using a complex optical setup, consisting of a wavefront shaper and a multimode optical fiber illuminated by coherent light, we succeeded to suppress any speckle-related background. Further, we can display independent images at multiple distances simultaneously, and alter the effective sharpness depth through the algorithm. Our results demonstrate that TAP can significantly enhance the image projection quality in multiple ways. We anticipate that our results will greatly complement any application in which the response to light irradiation is relatively slow (one microsecond with current technology) and where high-fidelity spatial distribution of optical power is required.
Collapse
|
8
|
Liu Y, Liu Q, Li Y, Xu B, Zhang J, He Z. High-resolution multi-wavelength lensless diffraction imaging with adaptive dispersion correction. OPTICS EXPRESS 2021; 29:7197-7209. [PMID: 33726225 DOI: 10.1364/oe.419128] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Accepted: 02/13/2021] [Indexed: 06/12/2023]
Abstract
Multi-wavelength imaging diffraction system is a promising phase imaging technology due to its advantages of no mechanical movement and low complexity. In a multi-wavelength focused system, spectral bandwidth and dispersion correction are critical for high resolution reconstruction. Here, an optical setup for the multi-wavelength lensless diffraction imaging system with adaptive dispersion correction is proposed. Three beams with different wavelengths are adopted to illuminate the test object, and then the diffraction patterns are recorded by a image sensor. The chromatic correction is successfully realized by a robust refocusing technique. High-resolution images can be finally retrieved through phase retrieval algorithm. The effectiveness and reliability of our method is demonstrated in numerical simulation and experiments. The proposed method has the potential to be an alternative technology for quantitative biological imaging.
Collapse
|
9
|
Boonzajer Flaes DE, Witte S. Interference probe ptychography for computational amplitude and phase microscopy. OPTICS EXPRESS 2018; 26:31372-31390. [PMID: 30650724 DOI: 10.1364/oe.26.031372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2018] [Accepted: 10/25/2018] [Indexed: 06/09/2023]
Abstract
We have developed an approach to Fresnel domain ptychography in which the illumination consists of an interference pattern. This pattern is conveniently created by overlapping two coherent beams at an angle. Only the phase and orientation of the interferometric fringe pattern needs to be scanned to reconstruct a high-fidelity object image, which alleviates the requirements for accurate sample positioning and system stability. As such, the resulting imaging systems can be constructed in an extremely simple and robust way. Object images are reconstructed from recorded Fresnel diffraction data using a modified ptychographical iterative engine. We demonstrate the capabilities of this imaging system by recording images of various biological samples, demonstrating quantitative phase contrast as well as a spatial resolution better than 2.2 μm.
Collapse
|
10
|
Zhang H, Stangner T, Wiklund K, Andersson M. Object plane detection and phase retrieval from single-shot holograms using multi-wavelength in-line holography. APPLIED OPTICS 2018; 57:9855-9862. [PMID: 30462021 DOI: 10.1364/ao.57.009855] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2018] [Accepted: 10/15/2018] [Indexed: 06/09/2023]
Abstract
Phase retrieval and the twin-image problem in digital in-line holographic microscopy can be resolved by iterative reconstruction routines. However, recovering the phase properties of an object in a hologram requires an object plane to be chosen correctly for reconstruction. In this work, we present a novel multi-wavelength iterative algorithm to determine the object plane using single-shot holograms recorded at multiple wavelengths in an in-line holographic microscope. Using micro-sized objects, we verify the object positioning capabilities of the method for various shapes and derive the phase information using synthetic and experimental data. Experimentally, we built a compact digital in-line holographic microscopy setup around a standard optical microscope with a regular RGB-CCD camera and acquired holograms of micro-spheres, E. coli, and red blood cells, which are illuminated using three lasers operating at 491 nm, 532 nm, and 633 nm, respectively. We demonstrate that our method provides accurate object plane detection and phase retrieval under noisy conditions, e.g., using low-contrast holograms with an inhomogeneous background. This method allows for automatic positioning and phase retrieval suitable for holographic particle velocimetry, and object tracking in biophysical or colloidal research.
Collapse
|
11
|
Zhou Y, Wu J, Bian Z, Suo J, Zheng G, Dai Q. Fourier ptychographic microscopy using wavelength multiplexing. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:66006. [PMID: 28613346 DOI: 10.1117/1.jbo.22.6.066006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2017] [Accepted: 05/22/2017] [Indexed: 06/07/2023]
Abstract
Fourier ptychographic microscopy (FPM) is a recently developed technique stitching low-resolution images in Fourier domain to realize wide-field high-resolution imaging. However, the time-consuming process of image acquisition greatly narrows its applications in dynamic imaging. We report a wavelength multiplexing strategy to speed up the acquisition process of FPM several folds. A proof-of-concept system is built to verify its feasibility. Distinguished from many current multiplexing methods in Fourier domain, we explore the potential of high-speed FPM in spectral domain. Compatible with most existing FPM methods, our strategy provides an approach to high-speed gigapixel microscopy. Several experimental results are also presented to validate the strategy.
Collapse
Affiliation(s)
- You Zhou
- Tsinghua University, Department of Automation, Beijing, China
| | - Jiamin Wu
- Tsinghua University, Department of Automation, Beijing, China
| | - Zichao Bian
- University of Connecticut, Biomedical Engineering, and Electrical and Computer Engineering, Storrs, Connecticut, United States
| | - Jinli Suo
- Tsinghua University, Department of Automation, Beijing, China
| | - Guoan Zheng
- University of Connecticut, Biomedical Engineering, and Electrical and Computer Engineering, Storrs, Connecticut, United States
| | - Qionghai Dai
- Tsinghua University, Department of Automation, Beijing, China
| |
Collapse
|
12
|
Compact, cost-effective and field-portable microscope prototype based on MISHELF microscopy. Sci Rep 2017; 7:43291. [PMID: 28233829 PMCID: PMC5324169 DOI: 10.1038/srep43291] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2016] [Accepted: 01/20/2017] [Indexed: 02/08/2023] Open
Abstract
We report on a reduced cost, portable and compact prototype design of lensless holographic microscope with an illumination/detection scheme based on wavelength multiplexing, working with single hologram acquisition and using a fast convergence algorithm for image processing. All together, MISHELF (initials coming from Multi-Illumination Single-Holographic-Exposure Lensless Fresnel) microscopy allows the recording of three Fresnel domain diffraction patterns in a single camera snap-shot incoming from illuminating the sample with three coherent lights at once. Previous implementations have proposed an illumination/detection procedure based on a tuned (illumination wavelengths centered at the maximum sensitivity of the camera detection channels) configuration but here we report on a detuned (non-centered ones) scheme resulting in prototype miniaturization and cost reduction. Thus, MISHELF microscopy in combination with a novel and fast iterative algorithm allows high-resolution (μm range) phase-retrieved (twin image elimination) quantitative phase imaging of dynamic events (video rate recording speed). The performance of this microscope prototype is validated through experiments using both amplitude (USAF resolution test) and complex (live swine sperm cells and flowing microbeads) samples. The proposed method becomes in an alternative instrument improving some capabilities of existing lensless microscopes.
Collapse
|
13
|
Kazemzadeh F, Wong A. Laser Light-field Fusion for Wide-field Lensfree On-chip Phase Contrast Microscopy of Nanoparticles. Sci Rep 2016; 6:38981. [PMID: 27958348 PMCID: PMC5154191 DOI: 10.1038/srep38981] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2016] [Accepted: 11/16/2016] [Indexed: 01/02/2023] Open
Abstract
Wide-field lensfree on-chip microscopy, which leverages holography principles to capture interferometric light-field encodings without lenses, is an emerging imaging modality with widespread interest given the large field-of-view compared to lens-based techniques. In this study, we introduce the idea of laser light-field fusion for lensfree on-chip phase contrast microscopy for detecting nanoparticles, where interferometric laser light-field encodings acquired using a lensfree, on-chip setup with laser pulsations at different wavelengths are fused to produce marker-free phase contrast images of particles at the nanometer scale. As a proof of concept, we demonstrate, for the first time, a wide-field lensfree on-chip instrument successfully detecting 300 nm particles across a large field-of-view of ~30 mm2 without any specialized or intricate sample preparation, or the use of synthetic aperture- or shift-based techniques.
Collapse
Affiliation(s)
- Farnoud Kazemzadeh
- Department of Systems Design Engineering, University of Waterloo, Waterloo, Ontario, N2L 3G1, Canada
| | - Alexander Wong
- Department of Systems Design Engineering, University of Waterloo, Waterloo, Ontario, N2L 3G1, Canada
| |
Collapse
|
14
|
Luo W, Zhang Y, Feizi A, Göröcs Z, Ozcan A. Pixel super-resolution using wavelength scanning. LIGHT, SCIENCE & APPLICATIONS 2016; 5:e16060. [PMID: 30167157 PMCID: PMC6059953 DOI: 10.1038/lsa.2016.60] [Citation(s) in RCA: 76] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2015] [Revised: 12/09/2015] [Accepted: 12/11/2015] [Indexed: 05/03/2023]
Abstract
Undersampling and pixelation affect a number of imaging systems, limiting the resolution of the acquired images, which becomes particularly significant for wide-field microscopy applications. Various super-resolution techniques have been implemented to mitigate this resolution loss by utilizing sub-pixel displacements in the imaging system, achieved, for example, by shifting the illumination source, the sensor array and/or the sample, followed by digital synthesis of a smaller effective pixel by merging these sub-pixel-shifted low-resolution images. Herein, we introduce a new pixel super-resolution method that is based on wavelength scanning and demonstrate that as an alternative to physical shifting/displacements, wavelength diversity can be used to boost the resolution of a wide-field imaging system and significantly increase its space-bandwidth product. We confirmed the effectiveness of this new technique by improving the resolution of lens-free as well as lens-based microscopy systems and developed an iterative algorithm to generate high-resolution reconstructions of a specimen using undersampled diffraction patterns recorded at a few wavelengths covering a narrow spectrum (10-30 nm). When combined with a synthetic-aperture-based diffraction imaging technique, this wavelength-scanning super-resolution approach can achieve a half-pitch resolution of 250 nm, corresponding to a numerical aperture of ~1.0, across a large field of view (>20 mm2). We also demonstrated the effectiveness of this approach by imaging various biological samples, including blood and Papanicolaou smears. Compared with displacement-based super-resolution techniques, wavelength scanning brings uniform resolution improvement in all directions across a sensor array and requires significantly fewer measurements. This technique would broadly benefit wide-field imaging applications that demand larger space-bandwidth products.
Collapse
Affiliation(s)
- Wei Luo
- Electrical Engineering Department, University of California, Los Angeles, CA 90095, USA
- Bioengineering Department, University of California, Los Angeles, CA 90095, USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095, USA
| | - Yibo Zhang
- Electrical Engineering Department, University of California, Los Angeles, CA 90095, USA
- Bioengineering Department, University of California, Los Angeles, CA 90095, USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095, USA
| | - Alborz Feizi
- Electrical Engineering Department, University of California, Los Angeles, CA 90095, USA
- Bioengineering Department, University of California, Los Angeles, CA 90095, USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095, USA
| | - Zoltán Göröcs
- Electrical Engineering Department, University of California, Los Angeles, CA 90095, USA
- Bioengineering Department, University of California, Los Angeles, CA 90095, USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095, USA
| | - Aydogan Ozcan
- Electrical Engineering Department, University of California, Los Angeles, CA 90095, USA
- Bioengineering Department, University of California, Los Angeles, CA 90095, USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095, USA
- Department of Surgery, David Geffen School of Medicine, University of California, Los Angeles, CA 90095, USA
| |
Collapse
|
15
|
Propagation phasor approach for holographic image reconstruction. Sci Rep 2016; 6:22738. [PMID: 26964671 PMCID: PMC4786813 DOI: 10.1038/srep22738] [Citation(s) in RCA: 49] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2015] [Accepted: 02/18/2016] [Indexed: 01/28/2023] Open
Abstract
To achieve high-resolution and wide field-of-view, digital holographic imaging techniques need to tackle two major challenges: phase recovery and spatial undersampling. Previously, these challenges were separately addressed using phase retrieval and pixel super-resolution algorithms, which utilize the diversity of different imaging parameters. Although existing holographic imaging methods can achieve large space-bandwidth-products by performing pixel super-resolution and phase retrieval sequentially, they require large amounts of data, which might be a limitation in high-speed or cost-effective imaging applications. Here we report a propagation phasor approach, which for the first time combines phase retrieval and pixel super-resolution into a unified mathematical framework and enables the synthesis of new holographic image reconstruction methods with significantly improved data efficiency. In this approach, twin image and spatial aliasing signals, along with other digital artifacts, are interpreted as noise terms that are modulated by phasors that analytically depend on the lateral displacement between hologram and sensor planes, sample-to-sensor distance, wavelength, and the illumination angle. Compared to previous holographic reconstruction techniques, this new framework results in five- to seven-fold reduced number of raw measurements, while still achieving a competitive resolution and space-bandwidth-product. We also demonstrated the success of this approach by imaging biological specimens including Papanicolaou and blood smears.
Collapse
|
16
|
Kazemzadeh F, Jin C, Molladavoodi S, Mei Y, Emelko MB, Gorbet MB, Wong A. Lens-free spectral light-field fusion microscopy for contrast- and resolution-enhanced imaging of biological specimens. OPTICS LETTERS 2015; 40:3862-3865. [PMID: 26274679 DOI: 10.1364/ol.40.003862] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
A lens-free spectral light-field fusion microscopy (LSLFM) system is presented for enabling contrast- and resolution-enhanced imaging of biological specimens. LSLFM consists of a pulsed multispectral lens-free microscope for capturing interferometric light-field encodings at various wavelengths, and Bayesian-based fusion to reconstruct a fused object light-field from the encodings. By fusing unique object detail information captured at different wavelengths, LSLFM can achieve improved resolution, contrast, and signal-to-noise ratio (SNR) over a single-channel lens-free microscopy system. A five-channel LSLFM system was developed and quantitatively evaluated to validate the design. Experimental results demonstrated that the LSLFM system provided SNR improvements of 6-12 dB, as well as a six-fold improvement in the dispersion index (DI), over that achieved using a single-channel, resolution-enhancing lens-free deconvolution microscopy system or its multi-wavelength counterpart. Furthermore, the LSLFM system achieved an increase in numerical aperture (NA) of ∼16% over a single-channel resolution-enhancing lens-free deconvolution microscopy system at the highest resolution wavelength used in the study. Samples of Staurastrum paradoxum, a waterborne algae, and human corneal epithelial cells were imaged using the system to illustrate its potential for enhanced imaging of biological specimens.
Collapse
|
17
|
Sanz M, Picazo-Bueno JA, García J, Micó V. Improved quantitative phase imaging in lensless microscopy by single-shot multi-wavelength illumination using a fast convergence algorithm. OPTICS EXPRESS 2015; 23:21352-65. [PMID: 26367983 DOI: 10.1364/oe.23.021352] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
We report on a novel algorithm for high-resolution quantitative phase imaging in a new concept of lensless holographic microscope based on single-shot multi-wavelength illumination. This new microscope layout, reported by Noom et al. along the past year and named by us as MISHELF (initials incoming from Multi-Illumination Single-Holographic-Exposure Lensless Fresnel) microscopy, rises from the simultaneous illumination and recording of multiple diffraction patterns in the Fresnel domain. In combination with a novel and fast iterative phase retrieval algorithm, MISHELF microscopy is capable of high-resolution (micron range) phase-retrieved (twin image elimination) biological imaging of dynamic events. In this contribution, MISHELF microscopy is demonstrated through qualitative concept description, algorithm implementation, and experimental validation using both a synthetic object (resolution test target) and a biological sample (swine sperm sample) for the case of three (RGB) illumination wavelengths. The proposed method becomes in an alternative instrument improving the capabilities of existing lensless microscopes.
Collapse
|
18
|
Bianco V, Paturzo M, Marchesano V, Gallotta I, Di Schiavi E, Ferraro P. Optofluidic holographic microscopy with custom field of view (FoV) using a linear array detector. LAB ON A CHIP 2015; 15:2117-24. [PMID: 25832808 DOI: 10.1039/c5lc00143a] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Simple and effective imaging strategies are of utmost interest for applications on a lab-on-chip scale. In fact, the majority of diagnostic tools for medical as well as biotechnological studies still employ image-based approaches. Having onboard the chip a compact but powerful imaging apparatus with multiple imaging capabilities, such as 3D dynamic focusing along the optical axis, unlimited field of view (FoV) and double outputs, namely, intensity and quantitative phase-contrast maps of biological objects, is of extreme importance for the next generation of Lab-on-a-Chip (LoC) devices. Here we present a coherent 3D microscopy approach with a holographic modality that is specifically suitable for studying biological samples while they simply flow along microfluidic paths. The LoC device is equipped with a compact linear array detector to capture and generate a new conceptual type of a digital hologram in the space-time domain, named here as Space-Time Digital Hologram (STDH). The reported results show that the method is a promising diagnostic tool for optofluidic investigations of biological specimens.
Collapse
Affiliation(s)
- V Bianco
- CNR-Istituto di Cibernetica "E. Caianiello", Via Campi Flegrei 34, I-80078, Pozzuoli (NA), Italy.
| | | | | | | | | | | |
Collapse
|