1
|
Zhou Y, Zhou W, Ren Z, Zhang Y, Gong H, Shen C, Chen RP, Albert J. In-situ monitoring of refractive index change during water-ice phase transition with a multiresonant fiber grating. OPTICS EXPRESS 2023; 31:31231-31242. [PMID: 37710647 DOI: 10.1364/oe.497679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Accepted: 08/29/2023] [Indexed: 09/16/2023]
Abstract
In-situ monitoring of refractive index changes during a liquid-solid phase transition is achieved by measurement of the transmission spectrum from a single tilted fiber Bragg grating immersed in water. Differential wavelength shifts of multiple mode resonances are used to eliminate cross-talk from temperature, throughout the phase transition, and from strains occurring after solidification. The measured sudden shift of refractive index at the phase transition is shown to be consistent with the expected difference from water to ice, in spite of the observed onset of compressive strain on the fiber by the frozen water. Beyond the obvious application to research on the dynamics of liquid-solid phase transitions, this work demonstrates the multiparameter measurement capabilities of multiresonant gratings.
Collapse
|
2
|
Liu F, Zhang X, Li K, Guo T, Ianoul A, Albert J. Discrimination of Bulk and Surface Refractive Index Change in Plasmonic Sensors with Narrow Bandwidth Resonance Combs. ACS Sens 2021; 6:3013-3023. [PMID: 34190543 DOI: 10.1021/acssensors.1c00906] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
A method to enable surface plasmon resonance (SPR) sensors to discriminate between bulk and surface-localized refractive index changes is demonstrated with modified gold-coated tilted fiber Bragg grating SPR sensors (TFBG-SPR). Without this capability, all high-resolution SPR sensors should be using reference channels and strict temperature control to prevent the contamination of the desired detection of surface-localized chemical or binding events by drift of the refractive index of the medium, in which the experiment is carried out. The very fine comb of high-quality-factor resonances of a TFBG-SPR device coupled to the large differential sensitivity of some of the resonances to various perturbations is used to measure unambiguously the refractive index changes within a surface layer thinner than 25 nm from those of the bulk surrounding. The enabling modification of the conventional TFBG-SPR is a reduction of the gold coating from its optimum value near 50-30 nm: at this lower thickness, a surface plasmon wave can still be excited by a limited number of cladding mode resonances, but at the same time, the metal is thin enough to allow modes away from the SPR to tunnel across the metal and probe the bulk RI value. Measurements and simulations of the deposition of a self-assembled monolayer of 1-dodecanethiol in ethanol show that the bulk refractive index changes as small as 0.0004 can be distinguished from the formation of a 1 nm thick coating on the surface of the fiber.
Collapse
Affiliation(s)
- Fu Liu
- Department of Electronics, Carleton University, Ottawa, Ontario K1S 5B6, Canada
| | - Xuejun Zhang
- Institute of Photonics Technology, Jinan University, Guangzhou 510632, China
| | - Kaiwei Li
- Institute of Photonics Technology, Jinan University, Guangzhou 510632, China
| | - Tuan Guo
- Institute of Photonics Technology, Jinan University, Guangzhou 510632, China
| | - Anatoli Ianoul
- Department of Chemistry, Carleton University, Ottawa, Ontario K1S 5B6, Canada
| | - Jacques Albert
- Department of Electronics, Carleton University, Ottawa, Ontario K1S 5B6, Canada
| |
Collapse
|
3
|
Liu Y, Jing Z, Liu Q, Li A, Lee A, Cheung Y, Zhang Y, Peng W. All-silica fiber-optic temperature-depth-salinity sensor based on cascaded EFPIs and FBG for deep sea exploration. OPTICS EXPRESS 2021; 29:23953-23966. [PMID: 34614649 DOI: 10.1364/oe.432943] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 07/03/2021] [Indexed: 06/13/2023]
Abstract
Using fusion splicing and hydroxide catalysis bonding (HCB) technology, an all-silica inline fiber-optic sensor with high-pressure survivability, high-resolution salinity measurement capability, and corrosion resistance for deep sea explorations is proposed and experimentally demonstrated. Two extrinsic Fabry-Perot interferometers (EFPIs) and a fiber Bragg grating (FBG) are cascaded in one single-mode fiber (SMF), enabling structural integration of single lead-in fiber and versatility of the sensing probe for temperature, depth, and salinity monitoring. The HCB technology offers a polymer adhesive-free assembly of one open-cavity EFPI for refractive index (RI) (salinity) sensing under normal pressure and temperature (NPT) conditions, showing obvious advantages of strong bonding strength, reliable effectiveness, and no corrosive chemicals requirements. The other EFPI formed by a fused structure is designed for pressure (depth) measurement. The cascading of EFPIs, especially the open-cavity EFPI immersed in water, will result in large light transmission loss and bring challenges to signal interrogation. Graded-index fiber (GIF) micro-collimators and reflective films are added to prevent dramatic degradations of signal intensity and fringe visibility underwater. Thereby, a Fabry-Perot (FP) cavity of several hundreds of microns in length and an open cavity of a thousand microns can be cascaded for underwater applications, effectively enhancing sensitivities and underwater signal readout simultaneously. Results show that the proposed sensor can well operate in the deep-sea pressure range of 0∼2039.43 mH2O, RI range of 1.33239∼1.36885 RIU, and temperature range of 23∼80 °C, with resolutions of 0.033 MPa, 4.16×10-7 RIU, and 0.54 °C, respectively. With the multi-parameter measurement capability, all-silica construction, and inline compact structure, the proposed sensor could be a potential candidate for deep sea exploration.
Collapse
|
4
|
Wang F, Duan Y, Lu M, Zhang Y, Jing Z, Sun C, Peng W. Linear-response and simple hot-wire fiber-optic anemometer using high-order cladding mode. OPTICS EXPRESS 2020; 28:27028-27036. [PMID: 32906964 DOI: 10.1364/oe.399774] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Accepted: 08/19/2020] [Indexed: 06/11/2023]
Abstract
We present a single walled carbon nanotubes (SWCNTs)-coated tilted fiber Bragg grating (TFBG) hot-wire anemometer (HWA) with simple configuration, linear response, and high sensitivity. TFBG is utilized to effectively couple a pumping laser at 1550 nm to the cladding mode that is absorbed by the SWCNTs film immobilized on the fiber surface with good light-heat conversion efficiency. As a result, the TFBG is converted to a "hot wire", and the wind speed can be deduced from the output power of the laser, which is a function of both the wind-induced temperature change and the spectral profile of the cladding mode. The most significant aspect of the HWA system is that we use the Gaussian shape of the high-order TFBG cladding mode to compensate for the inherent nonlinear relationship between the heat loss and the wind speed that is an undesirable characteristic of existing HWA systems. The validity of this novel operating principle was verified theoretically and experimentally. Via careful control of the parameters, a good linear response of the HWA system was achieved, especially for the low wind speed range where nonlinearity was more conspicuous. It was demonstrated that, with a low input power of only 29.3 mW of the pump laser, an R2 value of 0.9927 was obtained in this fiber-optic HWA system with high sensitivity 7.425 dBm / (m/s) and resolution 0.0027 m/s in a small wind speed range (0-2m/s) considering the intensity resolution of OSA and the noise of the pump laser. Furthermore, the system also exhibits a simple and low-cost design with only one laser source and one low-cost power measurement component.
Collapse
|
5
|
Caucheteur C, Loyez M, González-Vila Á, Wattiez R. Evaluation of gold layer configuration for plasmonic fiber grating biosensors. OPTICS EXPRESS 2018; 26:24154-24163. [PMID: 30184907 DOI: 10.1364/oe.26.024154] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2018] [Accepted: 08/28/2018] [Indexed: 05/22/2023]
Abstract
Gold-coated fiber Bragg gratings (FBGs) are nowadays a mature technology for lab-on-fiber sensing based on surface plasmon resonance (SPR) excitation. Tilted FBGs bring valuable assets such as easy light injection, remote operation in very small volumes of analytes and immunity to temperature fluctuations. Different gold configurations have been reported to date, without considering their relative performances in terms of biochemical sensing. In this work, we experimentally study the impact of the gold coating on the cladding mode distribution in the tilted FBG amplitude spectrum and subsequently on its sensitivity to cytokeratins used as biomarkers for cancer diagnosis. Some relevant configurations of gold coatings are produced and tested, relying on both the sputtering and electroless plating (ELP) processes. The obtained results confirm that the coating thickness and its roughness drive the biosensing performances. The experimental limit of detection for cytokeratins 17 sensing reaches 14 fM for the most sensitive configurations.
Collapse
|
6
|
Hypersensitivity and Applications of Cladding Modes of Optical Fibers Coated with Nanoscale Metal Layers. SENSORS 2018; 18:s18051518. [PMID: 29751642 PMCID: PMC5982096 DOI: 10.3390/s18051518] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/14/2018] [Revised: 05/05/2018] [Accepted: 05/08/2018] [Indexed: 11/17/2022]
Abstract
Theoretical and experimental results are presented to show that the complex effective index of the modes of optical fibers coated with non-uniform metal coatings of gold, silver, copper, or palladium, with thicknesses between 0 and 20 nm, acquire a greatly enhanced sensitivity to various forms of perturbations. Thickness changes of less than 1 nm can be measured as well as the binding of record low concentrations of chemical and biochemical species.
Collapse
|
7
|
Morphological Characteristics of Au Films Deposited on Ti: A Combined SEM-AFM Study. COATINGS 2018. [DOI: 10.3390/coatings8040121] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Deposited Au films and coatings are, nowadays, routinely used as active or passive elements in several innovative electronic, optoelectronic, sensing, and energy devices. In these devices, the physical properties of the Au films are strongly determined by the films nanoscale structure. In addition, in these devices, often, a layer of Ti is employed to promote adhesion and, so, influencing the nanoscale structure of the deposited Au film. In this work, we present experimental analysis on the nanoscale cross-section and surface morphology of Au films deposited on Ti. In particular, we sputter-deposited thick (>100 nm thickness) Au films on Ti foils and we used Scanning Electron Microscopy to analyze the films cross-sectional and surface morphology as a function of the Au film thickness and deposition angle. In addition, we analyzed the Au films surface morphology by Atomic Force Microscopy which allowed quantifying the films surface roughness versus the film thickness and deposition angle. The results establish a relation between the Au films cross-sectional and surface morphologies and surface roughness to the film thickness and deposition angle. These results allow setting a general working framework to obtain Au films on Ti with specific morphological and topographic properties for desired applications in which the Ti adhesion layer is needed for Au.
Collapse
|
8
|
Zhang Y, Wang F, Liu Z, Duan Z, Cui W, Han J, Gu Y, Wu Z, Jing Z, Sun C, Peng W. Fiber-optic anemometer based on single-walled carbon nanotube coated tilted fiber Bragg grating. OPTICS EXPRESS 2017; 25:24521-24530. [PMID: 29041396 DOI: 10.1364/oe.25.024521] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2017] [Accepted: 09/19/2017] [Indexed: 06/07/2023]
Abstract
In this work, a novel and simple optical fiber hot-wire anemometer based on single-walled carbon nanotubes (SWCNTs) coated tilted fiber Bragg grating (TFBG) is proposed and demonstrated. For the hot-wire wind speed sensor design, TFBG is an ideal in-fiber sensing structure due to its unique features. It is utilized as both light coupling and temperature sensing element without using any geometry-modified or uncommon fiber, which simplifies the sensor structure. To further enhance the thermal conversion capability, SWCNTs are coated on the surface of the TFBG instead of traditional metallic materials, which have excellent thermal characteristics. When a laser light is pumped into the sensor, the pump light propagating in the core will be easily coupled into cladding of the fiber via the TFBG and strongly absorbed by the SWCNTs thin film. This absorption acts like a hot-wire raising the local temperature of the fiber, which is accurately detected by the TFBG resonance shift. In the experiments, the sensor's performances were investigated and controlled by adjusting the inherent angle of the TFBG, the thickness of SWCNTs film, and the input power of the pump laser. It was demonstrated that the developed anemometer exhibited significant light absorption efficiency up to 93%, and the maximum temperature of the local area on the fiber was heated up to 146.1°C under the relatively low pump power of 97.76 mW. The sensitivity of -0.3667 nm/(m/s) at wind speed of 1.0 m/s was measured with the selected 12° TFBG and 1.6 μm film.
Collapse
|
9
|
Feng D, Zhou W, Qiao X, Albert J. High resolution fiber optic surface plasmon resonance sensors with single-sided gold coatings. OPTICS EXPRESS 2016; 24:16456-16464. [PMID: 27464098 DOI: 10.1364/oe.24.016456] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The surface plasmon resonance (SPR) performance of gold coated tilted fiber Bragg gratings (TFBG) at near infrared wavelengths is evaluated as a function of the angle between the tilt plane orientation and the direction of single- and double-sided, nominally 50 nm-thick gold metal depositions. Scanning electron microscope images show that the coating are highly non-uniform around the fiber circumference, varying between near zero and 50 nm. In spite of these variations, the experimental results show that the spectral signature of the TFBG-SPR sensors is similar to that of simulations based on perfectly uniform coatings, provided that the depositions are suitably oriented along the tilt plane direction. Furthermore, it is shown that even a (properly oriented) single-sided coating (over only half of the fiber circumference) is sufficient to provide a theoretically perfect SPR response with a bandwidth under 5 nm, and 90% attenuation. Finally, using a pair of adjacent TFBG resonances within the SPR response envelope, a power detection scheme is used to demonstrate a limit of detection of 3 × 10-6 refractive index units.
Collapse
|
10
|
Mandia DJ, Zhou W, Ward MJ, Joress H, Sims JJ, Giorgi JB, Albert J, Barry ST. The effect of ALD-grown Al₂O₃ on the refractive index sensitivity of CVD gold-coated optical fiber sensors. NANOTECHNOLOGY 2015; 26:434002. [PMID: 26437035 DOI: 10.1088/0957-4484/26/43/434002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The combined effect of nanoscale dielectric and metallic layers prepared by atomic layer deposition (ALD) and chemical vapor deposition (CVD) on the refractometric properties of tilted optical fiber Bragg gratings (TFBG) is studied. A high index intermediate layer made up of either 50 nm or 100 nm layers of Al2O3 (refractive index near 1.62) was deposited by ALD and followed by thin gold layers (30-65 nm) deposited from a known single-source gold (I) iminopyrrolidinate CVD precursor. The fabricated devices were immersed in different surrounding refractive indices (SRI) and the spectral transmission response of the TFBGs was measured. Preliminary results indicate that the addition of the dielectric Al2O3 pre-coating enhances the SRI sensitivity by up to 75% but this enhancement is highly dependent on the polarization and dielectric thickness. In fact, the sensitivity decreases by up to 50% for certain cases. These effects are discussed with support from TFBG simulations and models, by quantifying the penetration of the evanescently coupled light out of the fiber through the various coating layers. Additional characterization studies have been carried out on these samples to further correlate the optical behaviour of the coated TFBGs with the physical properties of the gold and Al2O3 layers, using atomic force microscopy x-ray photoelectron spectroscopy and an ensemble of other optical and x-ray absorption spectroscopy techniques. The purity, roughness, and morphology of gold thin films deposited by CVD onto the dielectric-TFBG surface are also provided.
Collapse
Affiliation(s)
- David J Mandia
- Carleton University, Department of Chemistry, 1125 Colonel By Drive, Ottawa, ON, K1S 5B6, Canada
| | | | | | | | | | | | | | | |
Collapse
|
11
|
Zhou W, Mandia DJ, Barry ST, Albert J. Absolute near-infrared refractometry with a calibrated tilted fiber Bragg grating. OPTICS LETTERS 2015; 40:1713-1716. [PMID: 25872055 DOI: 10.1364/ol.40.001713] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The absolute refractive indices (RIs) of water and other liquids are determined with an uncertainty of ±0.001 at near-infrared wavelengths by using the tilted fiber Bragg grating (TFBG) cladding mode resonances of a standard single-mode fiber to measure the critical angle for total internal reflection at the interface between the fiber and its surroundings. The necessary condition to obtain absolute RIs (instead of measuring RI changes) is a thorough characterization of the dispersion of the core mode effective index of the TFBG across the full range of its cladding mode resonance spectrum. This technique is shown to be competitive with the best available measurements of the RIs of water and NaCl solutions at wavelengths in the vicinity of 1550 nm.
Collapse
|