1
|
Xiong H, Shao L, Cao Y, Wang G, Wang R, Mei J, Liu K, Gao X. Neural Network Based Aliasing Spectral Decoupling Algorithm for Precise Mid-Infrared Multicomponent Gases Sensing. ACS Sens 2024; 9:4906-4914. [PMID: 39150333 DOI: 10.1021/acssensors.4c01514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/17/2024]
Abstract
Owing to the overlapping and cross-interference of absorption lines in multicomponent gases, the simultaneous measurement of such gases via laser absorption spectroscopy frequently necessitates the use of supplementary pressure sensors to distinguish the spectral lines. Alternatively, it requires multiple lasers combined with time-division multiplexing to independently scan the absorption peaks of each gas, thereby preventing interference from other gases. This inevitably escalates both the cost of the system and the complexity of the gas pathway. In response to these challenges, a mid-infrared sensor employing a neural network-based decoupling algorithm for aliasing spectral is developed, enabling the simultaneous detection of methane(CH4), water vapor(H2O), and ethane(C2H6). The sensor system underwent evaluation in a controlled laboratory environment. Allan deviation analysis revealed that the minimum detection limits for CH4,H2O, and C2H6 were 6.04, 118.44, and 1 ppb, respectively, with an averaging time of 3 s. The performance of the proposed sensor demonstrates that the aliasing spectral decoupling algorithm based on neural network combined with wavelength-modulated spectroscopy technology has the advantages of high sensitivity, low cost and low complexity, showing its potential for simultaneous detection of multicomponent trace gases in various fields.
Collapse
Affiliation(s)
- Hao Xiong
- College of Environmental Science and Optoelectronic Technology, University of Science and Technology of China, Hefei, Anhui 230026, China
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230037, China
| | - Ligang Shao
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230037, China
| | - Yuan Cao
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230037, China
| | - Guishi Wang
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230037, China
| | - Ruifeng Wang
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230037, China
| | - Jiaoxu Mei
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230037, China
| | - Kun Liu
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230037, China
| | - Xiaoming Gao
- College of Environmental Science and Optoelectronic Technology, University of Science and Technology of China, Hefei, Anhui 230026, China
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230037, China
| |
Collapse
|
2
|
Li J, Li M, Liu R, Guo Y, Yang D, Hou K. A homogeneous sampling membrane inlet photoelectron ionization miniature time-of-flight mass spectrometer for on-line determination of ethane. Talanta 2024; 267:125221. [PMID: 37742395 DOI: 10.1016/j.talanta.2023.125221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2023] [Revised: 09/10/2023] [Accepted: 09/16/2023] [Indexed: 09/26/2023]
Abstract
Ethane is the second largest component among natural gas, and the detection of ethane is an effective method for rapid identification of the leakage of the natural gas pipelines. In this work, a homogeneous sampling membrane inlet was developed and coupled with the homemade photoelectron ionization miniature time-of-flight mass spectrometer (PEI-mini-TOFMS) for in situ, on-line and highly sensitive ethane detection. The membrane area of the homogeneous sampling membrane inlet was increased from 490 mm2 to 1256 mm2, gaseous sample is injected from the top port and flowed through the membrane surface and out of the bottom two ports, with the three ports arranged in a triangular shape. The highest average flow velocity of the gas on the surface of the membrane reached 0.4 m s-1, and the optimal gas pressure in the PEI source was enhanced from 2.2 Pa to 4.0 Pa with this new design. The new design improved the comprehensive sensitivity of ethane by a factor of 3.0 compared with that of the traditional two-hole membrane inlet with the membrane area of 490 mm2. The semiconductor cold trap controlled the sample relative humidity (RH) at 10-12%, enabling direct sampling for highly sensitive analysis with RH as high as 70% and temperature from 7 °C to 40 °C. The quantitative range was 1-50 ppmv with a limit of detection (LOD, S/N = 3) lowered to 420 ppbv within 1 min, and zero humidity quantitative calibration with cold trap further reduced the relative standard deviation (RSD) of the signal intensities to 2.84%. The performance of the novel method developed in this work demonstrated a potential application on the above-ground natural gas pipelines leakage monitoring.
Collapse
Affiliation(s)
- Jing Li
- Environment Research Institute, Shandong University, 72 Binhai Road, Qingdao, 266237, China
| | - Mei Li
- Environment Research Institute, Shandong University, 72 Binhai Road, Qingdao, 266237, China.
| | - Ruidong Liu
- Environment Research Institute, Shandong University, 72 Binhai Road, Qingdao, 266237, China
| | - Yingzhe Guo
- Environment Research Institute, Shandong University, 72 Binhai Road, Qingdao, 266237, China
| | - Dong Yang
- Environment Research Institute, Shandong University, 72 Binhai Road, Qingdao, 266237, China
| | - Keyong Hou
- Environment Research Institute, Shandong University, 72 Binhai Road, Qingdao, 266237, China.
| |
Collapse
|
3
|
Bayrakli I, Akman H, Sari F. Sensor using a photo-acoustic absorption cell with two perpendicular acoustic resonators to analyze multiple molecules. APPLIED OPTICS 2023; 62:6689-6696. [PMID: 37706801 DOI: 10.1364/ao.495411] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Accepted: 08/14/2023] [Indexed: 09/15/2023]
Abstract
An ultra-high sensitivity multi-molecule sensor based on a photo-acoustic cell with two perpendicular acoustic resonators and a common microphone has been reported. In this work, a 4.5 µm distributed-feedback quantum cascade laser and a 1.5 µm external cavity diode laser (EC-DL) were used as optical excitation sources. Considering the spectral ranges of the lasers used, it is possible to analyze eight molecules (Q C L:N 2 O and C O 2, EC-DL: H 2 O, H 2 S, N H 3, CO, C H 4, and C 2 H 2). The N 2 O molecule was used to evaluate the performance of the photo-acoustic spectroscopy (PAS)-based sensor. A sensitivity of 0.073 V/ppm and a linearity of 0.99 were found by analyzing the PAS signal as a function of N 2 O concentration at 2237.656c m -1. The long-term performance of the sensor was determined by performing an Allan deviation analysis. A minimum detection limit of 9.8 ppb for 90 s integration time was achieved. The simultaneous multi-trace gas detection capability was verified by measurement of N 2 O, C O 2, and H 2 O. Depending on the coarse/fine-tuning ranges of the lasers used, the number of molecules analyzed can be further increased. Such a sensor could provide simultaneous diagnosis of many diseases through an analysis of breath air and simultaneous monitoring of the most important greenhouse gases.
Collapse
|
4
|
Gomółka G, Stępniewski G, Pysz D, Buczyński R, Klimczak M, Nikodem M. Highly sensitive methane detection using a mid-infrared interband cascade laser and an anti-resonant hollow-core fiber. OPTICS EXPRESS 2023; 31:3685-3697. [PMID: 36785355 DOI: 10.1364/oe.479963] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Accepted: 12/19/2022] [Indexed: 06/18/2023]
Abstract
For over a decade hollow-core fibers have been used in optical gas sensors in the role of gas cells. However, very few examples of actual real-life applications of those sensors have been demonstrated so far. In this paper, we present a highly-sensitive hollow-core fiber based methane sensor. Mid-infrared distributed feedback interband cascade laser operating near 3.27 µm is used to detect gas inside anti-resonant hollow-core fiber. R(3) line near 3057.71 cm-1 located in ν3 band of methane is targeted. Compact, lens-free optical setup with an all-silica negative curvature hollow-core fiber as the gas cell is demonstrated. Using wavelength modulation spectroscopy and 7.5-m-long fiber the detection limit as low as 1.54 ppbv (at 20 s) is obtained. The demonstrated system is applied for a week-long continuous monitoring of ambient methane and water vapor in atmospheric air at ground level. Diurnal cycles in methane concentrations are observed, what proves the sensor's usability in environmental monitoring.
Collapse
|
5
|
Wang R, Peng J, Cao Y, Mei J, Wang G, Liu K, Chen W, Gao X. Double-enhanced multipass cell-based wavelength modulation spectroscopy CH 4 sensor for ecological applications. OPTICS EXPRESS 2023; 31:3237-3248. [PMID: 36785320 DOI: 10.1364/oe.480496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Accepted: 12/19/2022] [Indexed: 06/18/2023]
Abstract
A novel CH4 sensor based on wavelength modulation spectroscopy with a multipass cell was developed for the soil respiration measurement of CH4. A home-made double-enhanced Herriot-type multipass cell with an effective absorption length of 73.926 m and a fiber-coupled distributed feedback diode laser emission at 1653.74 nm were used to design the sensor. The double enhancement of the effective optical pathlength of the multipass cell, absorption line locking, laser intensity normalization, and temperature control of the multipass cell were used to improve cell performance and achieve a minimum detection limit of 10 ppbv and a measurement precision of 6.4 ppbv. Finally, the potential of the developed CH4 sensor for ecological applications was verified by measuring the soil respiration of CH4 and monitoring of CH4 in the atmosphere over a long period.
Collapse
|
6
|
Zhao H, Zheng C, Pi M, Liang L, Song F, Zhang Y, Wang Y, Tittel FK. On-chip mid-infrared silicon-on-insulator waveguide methane sensor using two measurement schemes at 3.291 μm. Front Chem 2022; 10:953684. [PMID: 36082199 PMCID: PMC9445134 DOI: 10.3389/fchem.2022.953684] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Accepted: 07/29/2022] [Indexed: 11/18/2022] Open
Abstract
Portable or even on-chip detection of methane (CH4) is significant for environmental protection and production safety. However, optical sensing systems are usually based on discrete optical elements, which makes them unsuitable for the occasions with high portability requirement. In this work, we report on-chip silicon-on-insulator (SOI) waveguide CH4 sensors at 3.291 μm based on two measurement schemes including direct absorption spectroscopy (DAS) and wavelength modulation spectroscopy (WMS). In order to suppress noise, Kalman filter was adopted in signal processing. By optimizing the waveguide cross-section structure, an etch depth of 220 nm was selected with an experimentally high power confinement factor (PCF) of 23% and a low loss of only 0.71 dB/cm. A limit of detection (LoD) of 155 parts-per-million (ppm) by DAS and 78 ppm by WMS at an averaging time of 0.2 s were obtained for a 2 cm-long waveguide sensor. Compared to the chalcogenide (ChG) waveguide CH4 sensors at the same wavelength, the reported sensor reveals the minimum waveguide loss and the lowest LoD. Therefore the SOI waveguide sensor has the potential of on-chip gas sensing in the mid-infrared (MIR) waveband.
Collapse
Affiliation(s)
- Huan Zhao
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, China
| | - Chuantao Zheng
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, China
- *Correspondence: Chuantao Zheng, ; Lei Liang,
| | - Mingquan Pi
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, China
| | - Lei Liang
- State Key Laboratory of Luminescence and Applications, Changchun Institute of Optics Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, China
- *Correspondence: Chuantao Zheng, ; Lei Liang,
| | - Fang Song
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, China
| | - Yu Zhang
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, China
| | - Yiding Wang
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, China
| | - Frank K. Tittel
- Department of Electrical and Computer Engineering, Rice University, Houston, TX, United States
| |
Collapse
|
7
|
Zheng K, Yu L, Zheng C, Xi Z, Zhang Y, Yan G, Zhang H, Zhang Y, Wang Y, Tittel FK. Vehicle-Deployed Off-Axis Integrated Cavity Output Spectroscopic CH 4/C 2H 6 Sensor System for Mobile Inspection of Natural Gas Leakage. ACS Sens 2022; 7:1685-1697. [PMID: 35622089 DOI: 10.1021/acssensors.2c00373] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
A vehicle-deployed parts-per-billion in volume (ppbv)-level off-axis integrated cavity output spectroscopic (OA-ICOS) CH4/C2H6 sensor system was experimentally presented for mobile inspection of natural gas leakage in urban areas. For the time-division-multiplexing-based dual-gas sensor system, an antivibration 35-cm-long optical cavity with an effective path length of ∼2510 m was fabricated with a high-stability temperature and pressure control design. An Allan deviation analysis yielded a minimum detection limit of 0.2 ppbv for CH4 detection and 10 ppbv for C2H6 detection for a 1 s averaging time. A natural gas leakage source location algorithm was proposed using an improved hybrid Nelder-Mead simplex search method and a particle swarm optimization (NM-PSO) algorithm. For field industrial application, the accuracy of the sensor system and leakage source location algorithm was confirmed through a CH4/C2H6 cylinder leakage experiment on the campus. Furthermore, through natural gas pipeline network inspection measurements in urban areas, three types of leakage sources, including natural gas, biogas, and possible leakage source were respectively located and confirmed using the global positioning system and wind speed and direction measurement system, verifying the reliability and potential application of the vehicle-deployed inspection system for future natural gas pipeline leakage monitoring.
Collapse
Affiliation(s)
- Kaiyuan Zheng
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, P. R. China
| | - Ling Yu
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, P. R. China
| | - Chuantao Zheng
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, P. R. China
| | - Zhenhai Xi
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, P. R. China
| | - Yixiao Zhang
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, P. R. China
| | - Ge Yan
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, P. R. China
| | - Haipeng Zhang
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, P. R. China
| | - Yu Zhang
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, P. R. China
| | - Yiding Wang
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, P. R. China
| | - Frank K. Tittel
- Department of Electrical and Computer Engineering, Rice University, 6100 Main Street, Houston, Texas 77005, United States
| |
Collapse
|
8
|
Selective Mid-IR Metamaterial-Based Gas Sensor System: Proof of Concept and Performances Tests. NANOMATERIALS 2022; 12:nano12061009. [PMID: 35335822 PMCID: PMC8951643 DOI: 10.3390/nano12061009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Revised: 03/09/2022] [Accepted: 03/16/2022] [Indexed: 11/17/2022]
Abstract
In this paper, we propose a highly selective and efficient gas detection system based on a narrow-band IR metasurface emitter integrated with a resistive heater. In order to develop the sensor for the detection of specific gases, both the microheater and metasurface structures have been optimized in terms of geometry and materials. Devices with different metamaterial structures and geometries for the heater have been tested. Our prototype showed that the modification of the spectral response of metasurface-based structures is easily achieved by adapting the geometrical parameters of the plasmonic micro-/nanostructures in the metasurface. The advantage of this system is the on-chip integration of a thermal source with broad IR radiation with the metasurface structure, obtaining a compact selective radiation source. From the experimental data, narrow emission peaks (FWHM as low as 0.15 μm), corresponding to the CO2, CH4, and CO absorption bands, with a radiant power of a few mW were obtained. It has been shown that, by changing the bias voltage, a shift of a few tens of nm around the central emission wavelength can be obtained, allowing fine optimization for gas detection applications.
Collapse
|
9
|
Liu N, Xu L, Zhou S, Zhang L, Li J. Simultaneous Detection of Multiple Atmospheric Components Using an NIR and MIR Laser Hybrid Gas Sensing System. ACS Sens 2020; 5:3607-3616. [PMID: 33137254 DOI: 10.1021/acssensors.0c01910] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
A compact multi-gas sensor has been developed for simultaneous detection of atmospheric carbon monoxide (CO), nitrous oxide (N2O), and methane (CH4). Instead of the traditional time-division multiplexing detection technique, two lasers having center emission wavelengths of 1.653 μm (near-infrared (NIR) diode feedback (DFB) laser diode) and 4.56 μm (mid-infrared (MIR) quantum cascade laser) were simultaneously coupled to a multipass cell using a dichroic mirror, which significantly decreased the complexity of the measurement and increased the temporal resolution of the spectrometer. Wavelength modulation spectroscopy (WMS) with the second-harmonic detection technique (WMS-2f) was used to improve the detection sensitivity. A LabVIEW-based digital lock-in amplifier (DLIA) algorithm and system control unit was developed to make the system more compact and flexible. Allan deviation analysis indicates that detection limits of 6.36 ppb by volume for CO, 4.9 ppb by volume for N2O, and 23.6 ppb by volume for CH4 are obtained at 1 s averaging time, and the sensitivity can be improved to 0.44 ppb for CO, 0.41 ppb for N2O, and 2 ppb for CH4 at an optimal averaging time of 900 s. Two-day real-time measurement in ambient air was performed to demonstrate the long-term stability of the sensor system.
Collapse
Affiliation(s)
- Ningwu Liu
- Laser Spectroscopy and Sensing Laboratory, Anhui University, 230601 Hefei, China
| | - Linguang Xu
- Laser Spectroscopy and Sensing Laboratory, Anhui University, 230601 Hefei, China
| | - Sheng Zhou
- Laser Spectroscopy and Sensing Laboratory, Anhui University, 230601 Hefei, China
| | - Lei Zhang
- Laser Spectroscopy and Sensing Laboratory, Anhui University, 230601 Hefei, China
| | - Jingsong Li
- Laser Spectroscopy and Sensing Laboratory, Anhui University, 230601 Hefei, China
| |
Collapse
|
10
|
Cui H, Wang F, Huang Q, Yan J, Cen K. Sensitive detection of NO using a compact portable CW DFB-QCL-based WMS sensor. APPLIED OPTICS 2020; 59:9491-9498. [PMID: 33104669 DOI: 10.1364/ao.402484] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Accepted: 10/01/2020] [Indexed: 06/11/2023]
Abstract
This paper introduces a compact and portable sensor based on mid-infrared absorption spectroscopy for NO detection employing a room-temperature continuous wave (CW) distributed feedback quantum cascade laser (DFB-QCL) emitting at 1900.08cm-1. A software-based digital signal generator and lock-in amplifier, in combination with the wavelength modulation spectroscopy (WMS) technique, were used for the concentration measurement of NO. In addition, a Gabor filter denoising method was developed to improve the performance of the measurement system. As a result, a minimum detection limit of 42 ppbv can be achieved at 3 s integration time, and a measurement precision of 450 ppbv can be reached with a time resolution of 0.1 s. The performance of the compact portable sensor was verified by a series of experiments, denoting great potential of field application for sensitive NO sensing.
Collapse
|
11
|
Zheng H, Liu Y, Lin H, Kan R, Patimisco P, Sampaolo A, Giglio M, Zhu W, Yu J, Tittel FK, Spagnolo V, Chen Z. Sub-ppb-level CH 4 detection by exploiting a low-noise differential photoacoustic resonator with a room-temperature interband cascade laser. OPTICS EXPRESS 2020; 28:19446-19456. [PMID: 32672221 DOI: 10.1364/oe.391322] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Accepted: 06/11/2020] [Indexed: 06/11/2023]
Abstract
An ultra-highly sensitive and robust CH4 sensor is reported based on a 3.3 µm interband cascade laser (ICL) and a low-noise differential photoacoustic (PAS) cell. The ICL emission wavelength targeted a fundamental absorption line of CH4 at 2988.795 cm-1 with an intensity of 1.08 × 10-19 cm/molecule. The double-pass and differential design of the PAS cell effectively enhanced the PAS signal amplitude and decreased its background noise. The wavelength modulation depth, operating pressure and V-T relaxation promotion were optimized to maximize the sensor detection limit. With an integration time of 90 s, a detection limit of 0.6 ppb was achieved. No additional water or air laser cooling were required and thereby allowing the realization of a compact and robust CH4 sensor.
Collapse
|
12
|
Ma H, Sun M, Zhan S, Zhang Q, Zha S, Wang G, Liu K, Yi M, Cao Z. Compact dual-gas sensor for simultaneous measurement of atmospheric methane, and water vapor using a 3.38 μm antimonide-distributed feedback laser diode. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2020; 226:117605. [PMID: 31605968 DOI: 10.1016/j.saa.2019.117605] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2019] [Revised: 07/21/2019] [Accepted: 10/06/2019] [Indexed: 06/10/2023]
Abstract
A simple, compact sensor involving a continuous-wave 3.38 μm distributed feedback laser in combination with a novel compact dense-pattern multipass cell was demonstrated for simultaneous measurement of atmospheric methane and water vapor. The calibration-free direct absorption spectroscopy approach was adopted for data generation and processing. Allan deviation analysis indicates that minimum detection limits (1σ) of 11.0 ppb for CH4 and 100 ppm for H2O were achieved with a 1-s integration time at an optimum pressure of 50 Torr. Atmospheric environmental mixing ratios of these two gases were recorded and analyzed. This newly developed mid-infrared dual-gas sensor is very suitable for trace gas sensing in weight-limited unmanned aerial vehicle- or balloon-embedded field observations.
Collapse
Affiliation(s)
- Hongliang Ma
- School of Physics and Electrical Engineering, Anqing Normal University, Anqing, 246133, China
| | - Mingguo Sun
- Key Laboratory of Atmospheric Optics, Chinese Academy of Sciences, Hefei, 230031, China
| | - Shengbao Zhan
- School of Physics and Electrical Engineering, Anqing Normal University, Anqing, 246133, China
| | - Qilei Zhang
- School of Physics and Electrical Engineering, Anqing Normal University, Anqing, 246133, China
| | - Shenlong Zha
- School of Physics and Electrical Engineering, Anqing Normal University, Anqing, 246133, China
| | - Guishi Wang
- Key Laboratory of Atmospheric Optics, Chinese Academy of Sciences, Hefei, 230031, China
| | - Kun Liu
- Key Laboratory of Atmospheric Optics, Chinese Academy of Sciences, Hefei, 230031, China
| | - Mingfang Yi
- School of Physics and Electrical Engineering, Anqing Normal University, Anqing, 246133, China
| | - Zhensong Cao
- Key Laboratory of Atmospheric Optics, Chinese Academy of Sciences, Hefei, 230031, China.
| |
Collapse
|
13
|
Chen K, Liu S, Mei L, Jin F, Zhang B, Ma F, Chen Y, Deng H, Guo M, Yu Q. An auto-correction laser photoacoustic spectrometer based on 2f/1f wavelength modulation spectroscopy. Analyst 2020; 145:1524-1530. [DOI: 10.1039/c9an01799b] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
An auto-correction laser photoacoustic (PA) spectrometer based on 2f/1f wavelength modulation spectroscopy (WMS) has been proposed and demonstrated for trace gas detection to eliminate concentration measurement errors due to light power variations.
Collapse
Affiliation(s)
- Ke Chen
- School of Optoelectronic Engineering and Instrumentation Science
- Dalian University of Technology
- Dalian
- China
| | - Shuai Liu
- School of Optoelectronic Engineering and Instrumentation Science
- Dalian University of Technology
- Dalian
- China
| | - Liang Mei
- School of Optoelectronic Engineering and Instrumentation Science
- Dalian University of Technology
- Dalian
- China
| | - Feng Jin
- School of Optoelectronic Engineering and Instrumentation Science
- Dalian University of Technology
- Dalian
- China
| | - Bo Zhang
- School of Optoelectronic Engineering and Instrumentation Science
- Dalian University of Technology
- Dalian
- China
| | - Fengxiang Ma
- Electric Power Research Institute of State Grid Anhui Electric Power Co
- Ltd
- Hefei
- China
| | - Yewei Chen
- School of Optoelectronic Engineering and Instrumentation Science
- Dalian University of Technology
- Dalian
- China
| | - Hong Deng
- School of Optoelectronic Engineering and Instrumentation Science
- Dalian University of Technology
- Dalian
- China
| | - Min Guo
- School of Optoelectronic Engineering and Instrumentation Science
- Dalian University of Technology
- Dalian
- China
| | - Qingxu Yu
- School of Optoelectronic Engineering and Instrumentation Science
- Dalian University of Technology
- Dalian
- China
| |
Collapse
|
14
|
Razavipour SG, Gupta JA, Sabiston G, Sabourin N, Bezinger A, Lapointe J, Poitras D. Pressure-dependent sensitivity of a single-pass methane detection system using a continuous-wave distributed feedback laser at 3270 nm. APPLIED OPTICS 2019; 58:6906-6911. [PMID: 31503663 DOI: 10.1364/ao.58.006906] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Accepted: 07/30/2019] [Indexed: 06/10/2023]
Abstract
A single-pass, compact, and low-power-consumption methane sensing system is presented, and its sensitivity is examined for a set of reference cells with pressures of 7.4, 74, and 740 Torr and the same methane concentration at laboratory temperature of 23°C. A GaSb-based continuous-wave distributed feedback tunable diode laser at 3270 nm and wavelength modulation spectroscopy were employed to collect 2f spectra in the ν3, R3 band of CH412. The collected 2f spectra were fitted to a modulated Voigt line profile model. An Allan-Werle variance analysis shows that the best detectivity, 4 ppbm, is obtained for the highest pressure cell. At pressures of 74 and 7.4 Torr the detectivities are 16 and 28 ppbm, respectively. For these low-pressure cells, further sensitivity improvements were achieved using a large modulation depth (m>2.2) at the expense of spectral resolution.
Collapse
|
15
|
Recent Developments in Modulation Spectroscopy for Methane Detection Based on Tunable Diode Laser. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9142816] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
In this review, methane absorption characteristics mainly in the near-infrared region and typical types of currently available semiconductor lasers are described. Wavelength modulation spectroscopy (WMS), frequency modulation spectroscopy (FMS), and two-tone frequency modulation spectroscopy (TTFMS), as major techniques in modulation spectroscopy, are presented in combination with the application of methane detection.
Collapse
|
16
|
Yuan W, Zhang D, Lu S, Zhang HP, Guan Y. Fast-response concentration measurement of bromotrifluoromethane using a quantum cascade laser (QCL) at 8.280 μm. OPTICS EXPRESS 2019; 27:8838-8847. [PMID: 31052695 DOI: 10.1364/oe.27.008838] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Accepted: 12/10/2018] [Indexed: 06/09/2023]
Abstract
In this study, a measurement system for a gaseous fire extinguisher bromotrifluoromethane (Halon 1301) was developed, using a quantum cascade laser (QCL) at ~8.280 μm. The performance parameters of this system were also analyzed. Much higher sensitivity and faster response time were achieved compared to non-dispersive infrared (NDIR) sensors and differential-pressure method. A response time of 90 ms from 0% to the targeted concentration 6% was obtained. The detection limit of 500 ppm was obtained with a short optical path length of 2.8 mm. In conclusion, the proposed system can be applied in the airworthiness certification test of an aircraft fire suppression system.
Collapse
|
17
|
Zheng K, Zheng C, Yao D, Hu L, Liu Z, Li J, Zhang Y, Wang Y, Tittel FK. A near-infrared C 2H 2/CH 4 dual-gas sensor system combining off-axis integrated-cavity output spectroscopy and frequency-division-multiplexing-based wavelength modulation spectroscopy. Analyst 2019; 144:2003-2010. [PMID: 30698590 DOI: 10.1039/c8an02164c] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
By combining frequency division multiplexing assisted wavelength modulation spectroscopy (FDM-WMS) and off-axis integrated-cavity output spectroscopy (OA-ICOS), a near-infrared (near-IR) dual-gas sensor system was demonstrated for simultaneous chemical gas-phase detection of acetylene (C2H2) and methane (CH4). Two distributed feedback (DFB) lasers modulated at the frequency of 3 kHz and 4 kHz with an emitting wavelength of 1532 and 1653 nm were used to target two absorption lines, C2H2 at 6523.88 cm-1 and CH4 at 6046.95 cm-1, respectively. A 6 cm-long cavity was fabricated, which reveals an effective path length of 9.28 m (@1532 nm, C2H2) and 8.56 m (@1653 nm, CH4), respectively. Performances of the dual-gas sensor system were experimentally evaluated using C2H2 and CH4 samples generated by an Environics gas mixing system. An Allan deviation of 700 parts-per-billion in volume (ppbv) for C2H2 with an averaging time of 200 s and 850 ppbv for CH4 with an averaging time of 150 s was achieved for these two gas species. Dynamic measurements of a C2H2/CH4 : N2 mixture were performed for monitoring both C2H2 and CH4 simultaneously. This dual-gas sensor has the merits of reduced size and cost compared to two separate OA-ICOS sensors and reveals the minimum detectable column density (DCD) compared to other reported C2H2 and CH4 sensor systems.
Collapse
Affiliation(s)
- Kaiyuan Zheng
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, China.
| | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Liu Z, Zheng C, Chen C, Li Y, Xie H, Ren Q, Wang Y, Tittel FK. ICL-based mid-infrared carbon dioxide sensor system for deep-sea natural gas hydrate exploration. OPTICS EXPRESS 2019; 27:5598-5609. [PMID: 30876159 DOI: 10.1364/oe.27.005598] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2019] [Accepted: 02/08/2019] [Indexed: 06/09/2023]
Abstract
For deep-sea natural gas hydrate exploration, highly sensitive detection of the dissolved gas in seawater near the seabed is significant because it requires the sensor system to be small in size, low in power consumption, and high in sensitivity. A mid-infrared sensor system was developed to detect dissolved carbon dioxide (CO2) in sea-water, while employing a 4319 nm continuous-wave interband cascade laser (ICL) and a multi-pass gas cell (MPGC) with a 29.8 m optical path length. A compact rectilinear optical structure was proposed by using the free-space-emitting ICL and tunable laser absorption spectroscopy (TLAS). This leads to a minimized sensor size and a simple optical alignment for deep-sea operation. A strong CO2 absorption line, located at 2315.19 cm-1 and a weak 2315.28 cm-1 line and at a low pressure of 40 Torr, was targeted for low- and high-concentration CO2 detection within a concentration range of 0-1000 parts per billion by volume (ppbv) and 0-40 parts per million by volume (ppmv), respectively. The limit of detection (LoD) was assessed to be 0.72 ppbv at an averaging time of 2 s, and the response time was measured to be ~30 s at a flow rate of ~180 standard cubic centimeters per minute (sccm). Deployment of the CO2 sensor combined with a gas-liquid separator was carried out for the CO2 detection in the gas extracted from water, which validated the reported sensor system's potential application for deep-sea natural gas hydrate exploration.
Collapse
|
19
|
Mid-Infrared Tunable Laser-Based Broadband Fingerprint Absorption Spectroscopy for Trace Gas Sensing: A Review. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9020338] [Citation(s) in RCA: 66] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
The vast majority of gaseous chemical substances exhibit fundamental rovibrational absorption bands in the mid-infrared spectral region (2.5–25 μm), and the absorption of light by these fundamental bands provides a nearly universal means for their detection. A main feature of optical techniques is the non-intrusive in situ detection of trace gases. We reviewed primarily mid-infrared tunable laser-based broadband absorption spectroscopy for trace gas detection, focusing on 2008–2018. The scope of this paper is to discuss recent developments of system configuration, tunable lasers, detectors, broadband spectroscopic techniques, and their applications for sensitive, selective, and quantitative trace gas detection.
Collapse
|
20
|
Zheng K, Zheng C, He Q, Yao D, Hu L, Zhang Y, Wang Y, Tittel FK. Near-infrared acetylene sensor system using off-axis integrated-cavity output spectroscopy and two measurement schemes. OPTICS EXPRESS 2018; 26:26205-26216. [PMID: 30469711 DOI: 10.1364/oe.26.026205] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2018] [Accepted: 09/11/2018] [Indexed: 06/09/2023]
Abstract
For highly sensitive and accurate acetylene (C2H2) detection, a near-infrared (NIR) off-axis integrated-cavity output spectroscopy (OA-ICOS) sensor system based on an ultra-compact cage-based absorption cell was proposed. The absorption cell with dimensions of 10 cm × 8 cm × 6 cm realized a dense-pattern and an easily-aligned stable optical system. The OA-ICOS sensor system employed a 6cm-long optical cavity that was formed by two mirrors with a reflectivity of 99.35% and provided an effective absorption path length of ∼9.28 m. The performance of the C2H2 sensor system based on two measurement schemes, i.e. laser direct absorption spectroscopy (LDAS) and wavelength modulation spectroscopy (WMS) is reported. A NIR distributed feedback (DFB) laser was employed for targeting a C2H2 absorption line at 6523.88 cm-1. An Allan deviation analysis yielded a detection sensitivity of 760 parts-per-billion in volume (ppbv) for an averaging time of 304 s using the LDAS-based OA-ICOS. A detection sensitivity of 85 ppbv for an averaging time of 250 s was obtained using the WMS-based OA-ICOS, which was further improved by a factor of ~9 compared to the result obtained with the LDAS method. The proposed sensor system has the advantages of reduced size and cost with acceptable detection sensitivity, which is suitable for applications in trace gas sensing in harsh environments and weight-limited balloon-embedded observations.
Collapse
|
21
|
Cui R, Dong L, Wu H, Li S, Zhang L, Ma W, Yin W, Xiao L, Jia S, Tittel FK. Highly sensitive and selective CO sensor using a 2.33 μm diode laser and wavelength modulation spectroscopy. OPTICS EXPRESS 2018; 26:24318-24328. [PMID: 30469553 DOI: 10.1364/oe.26.024318] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2018] [Accepted: 08/27/2018] [Indexed: 06/09/2023]
Abstract
A ppm-level CO sensor based on a 2f wavelength modulation spectroscopy (2f-WMS) technique was developed for the application of SF6 decomposition analysis in an electric power system. A detailed investigation of the optimum target line selection was carried out to avoid spectral interference from high purity SF6 in a wide wavelength range. A diode laser emitting at 2.33 μm and a 14.5-m multipass gas cell (MGC) was employed to target the R(6) line of the CO first overtone band and increase the optical path, respectively, thus resulting in a minimum detection sensitivity of 1 ppm. A Levenberg-Marquardt nonlinear least-squares fit algorithm makes full use of the information from all data points of the 2f spectrum and as a result, a measurement precision of ~40 ppb was achieved with a data update rate of 0.6 s. The sensor performance was also evaluated in terms of the gas flow rate, stability, and linearity. The results showed that the best operating condition with a precision of 6 ppb can be achieved by increasing the gas flow rate to the value that matches the optimum averaging time of 48 s.
Collapse
|
22
|
Jin T, Zhou J, Wang Z, Gutierrez-Osuna R, Ahn C, Hwang W, Park K, Lin PT. Real-Time Gas Mixture Analysis Using Mid-Infrared Membrane Microcavities. Anal Chem 2018; 90:4348-4353. [PMID: 29509404 DOI: 10.1021/acs.analchem.7b03599] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Real-time gas analysis on-a-chip was demonstrated using a mid-infrared (mid-IR) microcavity. Optical apertures for the microcavity were made of ultrathin silicate membranes embedded in a silicon chip using the complementary metal-oxide-semiconductor (CMOS) process. Fourier transform infrared spectroscopy (FTIR) shows that the silicate membrane is transparent in the range of 2.5-6.0 μm, a region that overlaps with multiple characteristic gas absorption lines and therefore enables gas detection applications. A test station integrating a mid-IR tunable laser, a microgas delivery system, and a mid-IR camera was assembled to evaluate the gas detection performance. CH4, CO2, and N2O were selected as analytes due to their strong absorption bands at λ = 3.25-3.50, 4.20-4.35, and 4.40-4.65 μm, which correspond to C-H, C-O, and O-N stretching, respectively. A short subsecond response time and high gas identification accuracy were achieved. Therefore, our chip-scale mid-IR sensor provides a new platform for an in situ, remote, and embedded gas monitoring system.
Collapse
Affiliation(s)
| | | | | | | | - Charles Ahn
- Crucialtec Co., LTD , Seongnam-si , Gyeonggi-do 13486 , South Korea
| | - Wonjun Hwang
- Crucialtec Co., LTD , Seongnam-si , Gyeonggi-do 13486 , South Korea
| | - Ken Park
- Crucialtec Co., LTD , Seongnam-si , Gyeonggi-do 13486 , South Korea
| | | |
Collapse
|
23
|
Song F, Zheng C, Yan W, Ye W, Wang Y, Tittel FK. Interband cascade laser based mid-infrared methane sensor system using a novel electrical-domain self-adaptive direct laser absorption spectroscopy (SA-DLAS). OPTICS EXPRESS 2017; 25:31876-31888. [PMID: 29245857 DOI: 10.1364/oe.25.031876] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2017] [Accepted: 12/04/2017] [Indexed: 06/07/2023]
Abstract
To suppress sensor noise with unknown statistical properties, a novel self-adaptive direct laser absorption spectroscopy (SA-DLAS) technique was proposed by incorporating a recursive, least square (RLS) self-adaptive denoising (SAD) algorithm and a 3291 nm interband cascade laser (ICL) for methane (CH4) detection. Background noise was suppressed by introducing an electrical-domain noise-channel and an expectation-known-based RLS SAD algorithm. Numerical simulations and measurements were carried out to validate the function of the SA-DLAS technique by imposing low-frequency, high-frequency, White-Gaussian and hybrid noise on the ICL scan signal. Sensor calibration, stability test and dynamic response measurement were performed for the SA-DLAS sensor using standard or diluted CH4 samples. With the intrinsic sensor noise considered only, an Allan deviation of ~43.9 ppbv with a ~6 s averaging time was obtained and it was further decreased to 6.3 ppbv with a ~240 s averaging time, through the use of self-adaptive filtering (SAF). The reported SA-DLAS technique shows enhanced sensitivity compared to a DLAS sensor using a traditional sensing architecture and filtering method. Indoor and outdoor atmospheric CH4 measurements were conducted to validate the normal operation of the reported SA-DLAS technique.
Collapse
|
24
|
Zheng H, Lou M, Dong L, Wu H, Ye W, Yin X, Kim CS, Kim M, Bewley WW, Merritt CD, Canedy CL, Warren MV, Vurgaftman I, Meyer JR, Tittel FK. Compact photoacoustic module for methane detection incorporating interband cascade light emitting device. OPTICS EXPRESS 2017; 25:16761-16770. [PMID: 28789177 DOI: 10.1364/oe.25.016761] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
A photoacoustic module (PAM) for methane detection was developed by combining a novel 3.2 μm interband cascade light emitting device (ICLED) with a compact differential photoacoustic cell. The ICLED with a 22-stage interband cascade active core emitted a collimated power of ~700 μW. A concave Al-coat reflector was positioned adjacent to the photoacoustic cell to enhance the gas absorption length. Assembly of the ICLED and reflector with the photoacoustic cell resulted in a robust and portable PAM without any moving parts. The PAM performance was evaluated in terms of operating pressure, sensitivity and linearity. A 1σ detection limit of 3.6 ppmv was achieved with a 1-s integration time.
Collapse
|