1
|
Naranjo-Montoya OA, Bridger M, Bhar R, Kalkhoff L, Schleberger M, Wende H, Tarasevitch A, Bovensiepen U. Table-top source for x-ray absorption spectroscopy with photon energies up to 350 eV. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2024; 95:103001. [PMID: 39356188 DOI: 10.1063/5.0219921] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2024] [Accepted: 09/03/2024] [Indexed: 10/03/2024]
Abstract
We present a table-top setup for x-ray absorption spectroscopy (XAS) based on high harmonic generation (HHG) in noble gases. Using sub-millijoule pump pulses at a central wavelength of 1550 nm, broadband HHG in the range of 70-350 eV was demonstrated. The HHG coherence lengths of several millimeters were achieved by reaching the nonadiabatic regime of harmonic generation. Near edge x-ray absorption fine structure spectroscopy experiments on the boron K edge of a boron foil and a hexagonal boron nitride (hBN) 2D material demonstrate the capabilities of the setup. Femtosecond pulse duration makes pump-probe XAS experiments with corresponding time resolution possible.
Collapse
Affiliation(s)
- O A Naranjo-Montoya
- Faculty of Physics and Center for Nanointegration (CENIDE), University of Duisburg-Essen, Lotharstrasse 1, 47057 Duisburg, Germany
| | - M Bridger
- Faculty of Physics and Center for Nanointegration (CENIDE), University of Duisburg-Essen, Lotharstrasse 1, 47057 Duisburg, Germany
| | - R Bhar
- Faculty of Physics and Center for Nanointegration (CENIDE), University of Duisburg-Essen, Lotharstrasse 1, 47057 Duisburg, Germany
| | - L Kalkhoff
- Faculty of Physics and Center for Nanointegration (CENIDE), University of Duisburg-Essen, Lotharstrasse 1, 47057 Duisburg, Germany
| | - M Schleberger
- Faculty of Physics and Center for Nanointegration (CENIDE), University of Duisburg-Essen, Lotharstrasse 1, 47057 Duisburg, Germany
| | - H Wende
- Faculty of Physics and Center for Nanointegration (CENIDE), University of Duisburg-Essen, Lotharstrasse 1, 47057 Duisburg, Germany
| | - A Tarasevitch
- Faculty of Physics and Center for Nanointegration (CENIDE), University of Duisburg-Essen, Lotharstrasse 1, 47057 Duisburg, Germany
| | - U Bovensiepen
- Faculty of Physics and Center for Nanointegration (CENIDE), University of Duisburg-Essen, Lotharstrasse 1, 47057 Duisburg, Germany
| |
Collapse
|
2
|
Borchert M, Braenzel J, Gnewkow R, Lunin L, Sidiropoulos T, Tümmler J, Will I, Noll T, Reichel O, Rohloff D, Erko A, Krist T, von Korff Schmising C, Pfau B, Eisebitt S, Stiel H, Schick D. Versatile tabletop setup for picosecond time-resolved resonant soft-x-ray scattering and spectroscopy. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2023; 94:063102. [PMID: 37862537 DOI: 10.1063/5.0151613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Accepted: 05/31/2023] [Indexed: 10/22/2023]
Abstract
We present a laser-driven, bright, and broadband (50 to 1500 eV) soft-x-ray plasma source with <10 ps pulse duration. This source is employed in two complementary, laboratory-scale beamlines for time-resolved, magnetic resonant scattering and spectroscopy, as well as near-edge x-ray absorption fine-structure (NEXAFS) spectroscopy. In both beamlines, dedicated reflection zone plates (RZPs) are used as single optical elements to capture, disperse, and focus the soft x rays, reaching resolving powers up to E/ΔE > 1000, with hybrid RZPs at the NEXAFS beamline retaining a consistent E/ΔE > 500 throughout the full spectral range, allowing for time-efficient data acquisition. We demonstrate the versatility and performance of our setup by a selection of soft-x-ray spectroscopy and scattering experiments, which so far have not been possible on a laboratory scale. Excellent data quality, combined with experimental flexibility, renders our approach a true alternative to large-scale facilities, such as synchrotron-radiation sources and free-electron lasers.
Collapse
Affiliation(s)
- Martin Borchert
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
| | - Julia Braenzel
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
| | - Richard Gnewkow
- Helmholtz-Zentrum Berlin, 12489 Berlin, Germany
- Technische Universität Berlin, Institut für Optik und Atomare Physik, 10623 Berlin, Germany
- Berlin Laboratory for Innovative X-ray Technologies (BLiX), 10623 Berlin, Germany
| | - Leonid Lunin
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
| | | | - Johannes Tümmler
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
| | - Ingo Will
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
| | - Tino Noll
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
| | - Oliver Reichel
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
| | - Dirk Rohloff
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
| | | | - Thomas Krist
- NOB Nano Optics Berlin GmbH, 10627 Berlin, Germany
| | | | - Bastian Pfau
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
| | - Stefan Eisebitt
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
- Technische Universität Berlin, Institut für Optik und Atomare Physik, 10623 Berlin, Germany
| | - Holger Stiel
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
- Berlin Laboratory for Innovative X-ray Technologies (BLiX), 10623 Berlin, Germany
| | - Daniel Schick
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
| |
Collapse
|
3
|
Janulewicz KA, Węgrzyński Ł, Fok T, Bartnik A, Fiedorowicz H, Skruszewicz S, Wünsche M, Eckner E, Fuchs S, Reinhard J, Abel JJ, Wiesner F, Paulus GG, Rödel C, Kim CM, Wachulak PW. Broadband soft X-ray source from a clustered gas target dedicated to high-resolution XCT and X-ray absorption spectroscopy. OPTICS EXPRESS 2022; 30:47867-47878. [PMID: 36558705 DOI: 10.1364/oe.477726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Accepted: 11/21/2022] [Indexed: 06/17/2023]
Abstract
The development of the broad-bandwidth photon sources emitting in the soft X-ray range has attracted great attention for a long time due to the possible applications in high-resolution spectroscopy, nano-metrology, and material sciences. A high photon flux accompanied by a broad, smooth spectrum is favored for the applications such as near-edge X-ray absorption fine structure (NEXAFS), extended X-ray absorption fine structure (EXAFS), or XUV/X-ray coherence tomography (XCT). So far, either large-scale facilities or technologically challenging systems providing only limited photon flux in a single shot dominate the suitable sources. Here, we present a soft, broad-band (1.5 nm - 10.7 nm) soft X-ray source. The source is based on the interaction of very intense laser pulses with a target formed by a cluster mixture. A photon yield of 2.4 × 1014 photons/pulse into 4π (full space) was achieved with a medium containing Xe clusters of moderate-size mixed with a substantial amount of extremely large ones. It is shown that such a cluster mixture enhances the photon yield in the soft X-ray range by roughly one order of magnitude. The size of the resulting source is not beneficial (≤500 µm but this deficit is compensated by a specific spectral structure of its emission fulfilling the specific needs of the spectroscopic (broad spectrum and high signal dynamics) and metrological applications (broad and smoothed spectrum enabling a sub-nanometer resolution limit for XCT).
Collapse
|
4
|
Holburg J, Müller M, Mann K, Wild P, Eusterhues K, Thieme J. High-Resolution Table-Top NEXAFS Spectroscopy. Anal Chem 2022; 94:3510-3516. [PMID: 35175027 DOI: 10.1021/acs.analchem.1c04374] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
A table-top near-edge X-ray absorption fine structure (NEXAFS) spectroscopy system consisting of a soft X-ray source and an integrated spectrometer with a significantly improved resolution is presented. The soft X-ray source is based on a long-term stable and nearly debris-free picosecond laser-induced plasma generated in a pulsed krypton gas jet target. Photon energies ranging from 250 to 1000 eV can be used for the absorption spectroscopy of thin samples. The newly designed spectrometer accomplishes a spectral resolution of E/ΔE = 1535 at 430 eV, being close to typical synchrotron setups. Moreover, a simultaneous multi-edge analysis is possible. The performance of the new system is demonstrated by investigating the fine structure of the K- and L-absorption edges of various elements (carbon, calcium, oxygen, iron, nickel, and copper) for different types of samples. An excellent agreement with synchrotron spectra is achieved.
Collapse
Affiliation(s)
- Jonathan Holburg
- Institut für Nanophotonik Göttingen e.V., Hans-Adolf-Krebs-Weg 1, D-37077 Göttingen, Germany
| | - Matthias Müller
- Institut für Nanophotonik Göttingen e.V., Hans-Adolf-Krebs-Weg 1, D-37077 Göttingen, Germany
| | - Klaus Mann
- Institut für Nanophotonik Göttingen e.V., Hans-Adolf-Krebs-Weg 1, D-37077 Göttingen, Germany
| | - Philip Wild
- Institut für Geowissenschaften, Friedrich-Schiller-Universität Jena, Burgweg 11, D-07749 Jena, Germany
| | - Karin Eusterhues
- Institut für Geowissenschaften, Friedrich-Schiller-Universität Jena, Burgweg 11, D-07749 Jena, Germany
| | - Jürgen Thieme
- Brookhaven National Laboratory, National Synchrotron Light Source II, 743 Brookhaven Avenue, Upton, New York 11973-5000, United States
| |
Collapse
|
5
|
Design of Two-Mode Spectroscopic Sensor for Biomedical Applications: Analysis and Measurement of Relative Intensity Noise through Control Mechanism. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12041856] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
The design of an intracavity spectroscopy based two-mode biomedical sensor involves a thorough investigation of the system. For this purpose, the individual components that are present in the system must be examined. This work describes the principle of two very important gadgets, namely the Fibre Bragg Grating (FBG), and the tunable coupler. We adhere to a Petri network scheme to model and analyze the performance of the FBG, and the results mirror strikingly low difference in the values of Bragg Wavelength during its ascending and descending operational principle, thereby maintaining the accuracy of the sensor’s results. Next, a pseudocode is developed and implemented for the investigation of the optical coupler in LabView. The values of its maximum output power are determined, and the coupling ratio for various values of controlling voltage is determined at three different wavelengths. The hysteresis results mirror an extremely low difference between the forward and reverse values in the results. Both the results of the FBG and the coupler are thereby extremely reliable to use them in the laser system, as evident from the respective intensity noise outcomes, as well as the experimentation on substances of interest (Dichloro Methane and Propofol).
Collapse
|
6
|
Loetgering L, Witte S, Rothhardt J. Advances in laboratory-scale ptychography using high harmonic sources [Invited]. OPTICS EXPRESS 2022; 30:4133-4164. [PMID: 35209658 DOI: 10.1364/oe.443622] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Accepted: 12/22/2021] [Indexed: 06/14/2023]
Abstract
Extreme ultraviolet microscopy and wavefront sensing are key elements for next-generation ultrafast applications, such as chemically-resolved imaging, focal spot diagnostics in pump-and-probe experiments, and actinic metrology for the state-of-the-art lithography node at 13.5 nm wavelength. Ptychography offers a robust solution to the aforementioned challenges. Originally adapted by the electron and synchrotron communities, advances in the stability and brightness of high-harmonic tabletop sources have enabled the transfer of ptychography to the laboratory. This review covers the state of the art in tabletop ptychography with high harmonic generation sources. We consider hardware options such as illumination optics and detector concepts as well as algorithmic aspects in the analysis of multispectral ptychography data. Finally, we review technological application cases such as multispectral wavefront sensing, attosecond pulse characterization, and depth-resolved imaging.
Collapse
|
7
|
Stiel H, Braenzel J, Jonas A, Gnewkow R, Glöggler LT, Sommer D, Krist T, Erko A, Tümmler J, Mantouvalou I. Towards Understanding Excited-State Properties of Organic Molecules Using Time-Resolved Soft X-ray Absorption Spectroscopy. Int J Mol Sci 2021; 22:13463. [PMID: 34948258 PMCID: PMC8706469 DOI: 10.3390/ijms222413463] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Revised: 12/01/2021] [Accepted: 12/08/2021] [Indexed: 11/16/2022] Open
Abstract
The extension of the pump-probe approach known from UV/VIS spectroscopy to very short wavelengths together with advanced simulation techniques allows a detailed analysis of excited-state dynamics in organic molecules or biomolecular structures on a nanosecond to femtosecond time level. Optical pump soft X-ray probe spectroscopy is a relatively new approach to detect and characterize optically dark states in organic molecules, exciton dynamics or transient ligand-to-metal charge transfer states. In this paper, we describe two experimental setups for transient soft X-ray absorption spectroscopy based on an LPP emitting picosecond and sub-nanosecond soft X-ray pulses in the photon energy range between 50 and 1500 eV. We apply these setups for near-edge X-ray absorption fine structure (NEXAFS) investigations of thin films of a metal-free porphyrin, an aggregate forming carbocyanine and a nickel oxide molecule. NEXAFS investigations have been carried out at the carbon, nitrogen and oxygen K-edge as well as on the Ni L-edge. From time-resolved NEXAFS carbon, K-edge measurements of the metal-free porphyrin first insights into a long-lived trap state are gained. Our findings are discussed and compared with density functional theory calculations.
Collapse
Affiliation(s)
- Holger Stiel
- Berlin Laboratory for Innovative X-ray Technologies (BLiX), D-10623 Berlin, Germany; (J.B.); (A.J.); (R.G.); (L.T.G.); (J.T.); (I.M.)
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, D-12489 Berlin, Germany;
| | - Julia Braenzel
- Berlin Laboratory for Innovative X-ray Technologies (BLiX), D-10623 Berlin, Germany; (J.B.); (A.J.); (R.G.); (L.T.G.); (J.T.); (I.M.)
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, D-12489 Berlin, Germany;
| | - Adrian Jonas
- Berlin Laboratory for Innovative X-ray Technologies (BLiX), D-10623 Berlin, Germany; (J.B.); (A.J.); (R.G.); (L.T.G.); (J.T.); (I.M.)
- Analytical X-ray Physics, TU Berlin, D-10623 Berlin, Germany
| | - Richard Gnewkow
- Berlin Laboratory for Innovative X-ray Technologies (BLiX), D-10623 Berlin, Germany; (J.B.); (A.J.); (R.G.); (L.T.G.); (J.T.); (I.M.)
- Analytical X-ray Physics, TU Berlin, D-10623 Berlin, Germany
- Helmholtz Zentrum Berlin, D-12489 Berlin, Germany
| | - Lisa Theresa Glöggler
- Berlin Laboratory for Innovative X-ray Technologies (BLiX), D-10623 Berlin, Germany; (J.B.); (A.J.); (R.G.); (L.T.G.); (J.T.); (I.M.)
- Analytical X-ray Physics, TU Berlin, D-10623 Berlin, Germany
| | - Denny Sommer
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, D-12489 Berlin, Germany;
| | - Thomas Krist
- NOB Nano Optics Berlin GmbH, D-10627 Berlin, Germany;
| | | | - Johannes Tümmler
- Berlin Laboratory for Innovative X-ray Technologies (BLiX), D-10623 Berlin, Germany; (J.B.); (A.J.); (R.G.); (L.T.G.); (J.T.); (I.M.)
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, D-12489 Berlin, Germany;
| | - Ioanna Mantouvalou
- Berlin Laboratory for Innovative X-ray Technologies (BLiX), D-10623 Berlin, Germany; (J.B.); (A.J.); (R.G.); (L.T.G.); (J.T.); (I.M.)
- Analytical X-ray Physics, TU Berlin, D-10623 Berlin, Germany
- Helmholtz Zentrum Berlin, D-12489 Berlin, Germany
| |
Collapse
|
8
|
Demonstration of Near Edge X-ray Absorption Fine Structure Spectroscopy of Transition Metals Using Xe/He Double Stream Gas Puff Target Soft X-ray Source. MATERIALS 2021; 14:ma14237337. [PMID: 34885490 PMCID: PMC8658430 DOI: 10.3390/ma14237337] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 11/26/2021] [Accepted: 11/27/2021] [Indexed: 11/16/2022]
Abstract
A near 1-keV photons from the Xe/He plasma produced by the interaction of laser beam with a double stream gas puff target were employed for studies of L absorption edges of period 4 transitional metals with atomic number Z from 26 to 30. The dual-channel, compact NEXAFS system was employed for the acquisition of the absorption spectra. L1-3 absorption edges of the samples were identified in transmission mode using broadband emission from the Xe/He plasma to show the applicability of such source and measurement system to the NEXAFS studies of the transition metals, including magnetic materials.
Collapse
|
9
|
Jonas A, Stiel H, Glöggler L, Dahm D, Dammer K, Kanngießer B, Mantouvalou I. Towards Poisson noise limited optical pump soft X-ray probe NEXAFS spectroscopy using a laser-produced plasma source: erratum. OPTICS EXPRESS 2021; 29:13518. [PMID: 33985083 DOI: 10.1364/oe.425037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Indexed: 06/12/2023]
Abstract
We provide corrections for our previous publication [Opt. Express27, 36524 (2019)10.1364/OE.27.036524].
Collapse
|
10
|
Jonas A, Staeck S, Kanngießer B, Stiel H, Mantouvalou I. Laboratory quick near edge x-ray absorption fine structure spectroscopy in the soft x-ray range with 100 Hz frame rate using CMOS technology. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:023102. [PMID: 33648064 DOI: 10.1063/5.0032628] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Accepted: 01/24/2021] [Indexed: 06/12/2023]
Abstract
In laboratory based x-ray absorption fine structure (XAFS) spectroscopy, the slow readout speed of conventional CCD cameras can prolong the measuring times by multiple orders of magnitude. Using pulsed sources, e.g., laser-based x-ray sources, the pulse repetition rate often exceeds the frame rate of the CCD camera. We report the use of a scientific CMOS (sCMOS) camera for XAFS spectroscopy with a laser-produced plasma source facilitating measurements at 100 Hz. With this technological improvement, a new class of experiments becomes possible, starting from the time consuming analysis of samples with small absorption to pump-probe investigations. Furthermore, laboratory quick soft x-ray absorption fine structure (QXAFS) measurements with 10 ms time resolution are rendered feasible. We present the characterization of the sCMOS camera concerning noise characteristics and a comparison to conventional CCD camera performance. The feasibility of time resolved QXAFS measurements is shown by analyzing the statistical uncertainty of single shot spectra. Finally, XAFS spectroscopy on a complex sandwich structure with minute amounts of NiO exemplifies the additional merits of fast detectors.
Collapse
Affiliation(s)
- Adrian Jonas
- Berlin Laboratory for Innovative X-ray Technologies (BLiX), D-10623 Berlin, Germany
| | - Steffen Staeck
- Berlin Laboratory for Innovative X-ray Technologies (BLiX), D-10623 Berlin, Germany
| | - Birgit Kanngießer
- Berlin Laboratory for Innovative X-ray Technologies (BLiX), D-10623 Berlin, Germany
| | - Holger Stiel
- Berlin Laboratory for Innovative X-ray Technologies (BLiX), D-10623 Berlin, Germany
| | - Ioanna Mantouvalou
- Berlin Laboratory for Innovative X-ray Technologies (BLiX), D-10623 Berlin, Germany
| |
Collapse
|
11
|
Géneaux R, Chang HT, Schwartzberg AM, Marroux HJB. Source noise suppression in attosecond transient absorption spectroscopy by edge-pixel referencing. OPTICS EXPRESS 2021; 29:951-960. [PMID: 33726320 DOI: 10.1364/oe.412117] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Accepted: 12/01/2020] [Indexed: 06/12/2023]
Abstract
Attosecond transient absorption spectroscopy (ATAS) is used to observe photoexcited dynamics with outstanding time resolution. The main experimental challenge of this technique is that high-harmonic generation sources show significant instabilities, resulting in sub-par sensitivity when compared to other techniques. This paper proposes edge-pixel referencing as a means to suppress this noise. Two approaches are introduced: the first is deterministic and uses a correlation analysis, while the second relies on singular value decomposition. Each method is demonstrated and quantified on a noisy measurement taken on WS2 and results in a fivefold increase in sensitivity. The combination of the two methods ensures the fidelity of the procedure and can be implemented on live data collection but also on existing datasets. The results show that edge-referencing methods bring the sensitivity of ATAS near the detector noise floor. An implementation of the post-processing code is provided to the reader.
Collapse
|
12
|
Jonas A, Dammer K, Stiel H, Kanngiesser B, Sánchez-de-Armas R, Mantouvalou I. Transient Sub-nanosecond Soft X-ray NEXAFS Spectroscopy on Organic Thin Films. Anal Chem 2020; 92:15611-15615. [PMID: 33206514 DOI: 10.1021/acs.analchem.0c03845] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
We demonstrate visible pump soft X-ray probe near-edge X-ray absorption fine structure (NEXAFS) spectroscopy measurements at the carbon K edge on thin molecular films in the laboratory. This opens new opportunities through the use of laboratory equipment for chemical speciation. We investigate the metal-free porphyrin derivative tetra(tert-butyl)porphyrazine as an ideal model system to elucidate electronic properties of tetrapyrroles like chlorophyll or heme. In contrast to measurements in gas or liquid state, the investigation of thin films is of high interest in the field of optoelectronic and photovoltaic devices though challenging due to the low damage thresholds of the samples upon excitation. With a careful pre-characterization using optical techniques, successful measurements were performed using a NEXAFS spectrometer based on a laser-produced plasma source and reflection zone plates with a resolving power of 1000 and a time resolution of 0.5 ns. In combination with density functional theory calculations, first insights into a long-lived excitonic state are gained and discussed.
Collapse
Affiliation(s)
- Adrian Jonas
- Berlin Laboratory for Innovative X-ray Technologies (BLiX), D-10623 Berlin, Germany.,Analytical X-ray Physics, TU Berlin, D-10623 Berlin, Germany
| | - Katharina Dammer
- Berlin Laboratory for Innovative X-ray Technologies (BLiX), D-10623 Berlin, Germany.,Analytical X-ray Physics, TU Berlin, D-10623 Berlin, Germany
| | - Holger Stiel
- Berlin Laboratory for Innovative X-ray Technologies (BLiX), D-10623 Berlin, Germany.,Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, D-12489 Berlin, Germany
| | - Birgit Kanngiesser
- Berlin Laboratory for Innovative X-ray Technologies (BLiX), D-10623 Berlin, Germany.,Analytical X-ray Physics, TU Berlin, D-10623 Berlin, Germany
| | | | - Ioanna Mantouvalou
- Berlin Laboratory for Innovative X-ray Technologies (BLiX), D-10623 Berlin, Germany.,Analytical X-ray Physics, TU Berlin, D-10623 Berlin, Germany
| |
Collapse
|