1
|
Zhang C, Yang Q, Meng X, Li H, Luo Z, Kai L, Liang J, Chen S, Chen F. Wireless, Smart Hemostasis Device with All-Soft Sensing System for Quantitative and Real-Time Pressure Evaluation. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2303418. [PMID: 37688344 PMCID: PMC10667811 DOI: 10.1002/advs.202303418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Revised: 08/21/2023] [Indexed: 09/10/2023]
Abstract
The properly applied pressure between the skin and hemostasis devices is an essential parameter for preventing bleeding and postoperative complications after a transradial procedure. However, this parameter is usually controlled based on the subjective judgment of doctors, which might cause insufficient hemostatic effect or thrombosis. Here this study develops a compact and wireless sensing system for continuously monitoring the pressure applied on the radial artery and wrist skin in clinical practice. A liquid metal (LM)-based all-soft pressure sensor is fabricated to enable conformal attachment between the device and skin even under large deformation conditions. The linear sensitivity of 0.007 kPa-1 among the wide pressure range of 0-100 kPa is achieved and the real-time detection data can be wirelessly transmitted to mobile clients as a reference pressure value. With these devices, detailed pressure data can be collected, analyzed, and stored for medical assistance as well as to improve surgery quality.
Collapse
Affiliation(s)
- Chengjun Zhang
- School of Mechanical EngineeringXi'an Jiaotong UniversityXi'an710049P. R. China
| | - Qing Yang
- School of Mechanical EngineeringXi'an Jiaotong UniversityXi'an710049P. R. China
| | - Xianglin Meng
- Department of Critical Care MedicineThe First Affiliated Hospital of Harbin Medical UniversityHarbin150001P. R. China
| | - Haoyu Li
- State Key Laboratory for Manufacturing System Engineering and Shaanxi Key Laboratory of Photonics Technology for InformationSchool of Electronic Science and EngineeringXi'an Jiaotong UniversityXi'an710049P. R. China
| | - Zexiang Luo
- State Key Laboratory for Manufacturing System Engineering and Shaanxi Key Laboratory of Photonics Technology for InformationSchool of Electronic Science and EngineeringXi'an Jiaotong UniversityXi'an710049P. R. China
| | - Lin Kai
- State Key Laboratory for Manufacturing System Engineering and Shaanxi Key Laboratory of Photonics Technology for InformationSchool of Electronic Science and EngineeringXi'an Jiaotong UniversityXi'an710049P. R. China
| | - Jie Liang
- State Key Laboratory for Manufacturing System Engineering and Shaanxi Key Laboratory of Photonics Technology for InformationSchool of Electronic Science and EngineeringXi'an Jiaotong UniversityXi'an710049P. R. China
| | - Sicheng Chen
- School of Electrical and Electronic EngineeringNanyang Technological University50 Nanyang AvenueSingapore639798Singapore
| | - Feng Chen
- State Key Laboratory for Manufacturing System Engineering and Shaanxi Key Laboratory of Photonics Technology for InformationSchool of Electronic Science and EngineeringXi'an Jiaotong UniversityXi'an710049P. R. China
| |
Collapse
|
2
|
Makarov S, Grigoryev S, Inogamov N, Filippov E, Pikuz T, Ozaki N, Ishino M, Nishikino M, Dinh TH, Kawachi T, Zanaveskin M, Makita M, Nakatsutsumi M, Preston TR, Appel K, Konopkova Z, Cerantola V, Brambrink E, Schwinkendorf JP, Mohacsi I, Vozda V, Hajkova V, Burian T, Chalupsky J, Juha L, Zhakhovsky V, Zastrau U, Pikuz S. Damage threshold of LiF crystal irradiated by femtosecond hard XFEL pulse sequence. OPTICS EXPRESS 2023; 31:26383-26397. [PMID: 37710501 DOI: 10.1364/oe.486868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Accepted: 06/26/2023] [Indexed: 09/16/2023]
Abstract
Here we demonstrate the results of investigating the damage threshold of a LiF crystal after irradiating it with a sequence of coherent femtosecond pulses using the European X-ray Free Electron Laser (EuXFEL). The laser fluxes on the crystal surface varied in the range ∼ 0.015-13 kJ/cm2 per pulse when irradiated with a sequence of 1-100 pulses (tpulse ∼ 20 fs, Eph = 9 keV). Analysis of the surface of the irradiated crystal using different reading systems allowed the damage areas and the topology of the craters formed to be accurately determined. It was found that the ablation threshold decreases with increasing number of X-ray pulses, while the depth of the formed craters increases non-linearly and reaches several hundred nanometers. The obtained results have been compared with data already available in the literature for nano- and picosecond pulses from lasers in the soft X-ray/VUV and optical ranges. A failure model of lithium fluoride is developed and verified with simulation of material damage under single-pulse irradiation. The obtained damage threshold is in reasonably good agreement with the experimentally measured one.
Collapse
|
3
|
Chen H, Luo Z, Lin X, Zhu Y, Zhao Y. Sensors-integrated organ-on-a-chip for biomedical applications. NANO RESEARCH 2023; 16:1-28. [PMID: 37359077 PMCID: PMC10130312 DOI: 10.1007/s12274-023-5651-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 03/04/2023] [Accepted: 03/17/2023] [Indexed: 06/28/2023]
Abstract
As a promising new micro-physiological system, organ-on-a-chip has been widely utilized for in vitro pharmaceutical study and tissues engineering based on the three-dimensional constructions of tissues/organs and delicate replication of in vivo-like microenvironment. To better observe the biological processes, a variety of sensors have been integrated to realize in-situ, real-time, and sensitive monitoring of critical signals for organs development and disease modeling. Herein, we discuss the recent research advances made with respect to sensors-integrated organ-on-a-chip in this overall review. Firstly, we briefly explore the underlying fabrication procedures of sensors within microfluidic platforms and several classifications of sensory principles. Then, emphasis is put on the highlighted applications of different types of organ-on-a-chip incorporated with various sensors. Last but not least, perspective on the remaining challenges and future development of sensors-integrated organ-on-a-chip are presented.
Collapse
Affiliation(s)
- Hanxu Chen
- Department of Rheumatology and Immunology, Nanjing Drum Tower Hospital, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096 China
| | - Zhiqiang Luo
- Department of Rheumatology and Immunology, Nanjing Drum Tower Hospital, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096 China
| | - Xiang Lin
- Department of Rheumatology and Immunology, Nanjing Drum Tower Hospital, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096 China
| | - Yujuan Zhu
- Department of Rheumatology and Immunology, Nanjing Drum Tower Hospital, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096 China
| | - Yuanjin Zhao
- Department of Rheumatology and Immunology, Nanjing Drum Tower Hospital, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096 China
- Oujiang Laboratory (Zhejiang Lab for Regenerative Medicine, Vision and Brain Health), Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, 325001 China
| |
Collapse
|
4
|
Sun K, Whiteside B, Hebda M, Fan Y, Zhang Y, Xie Y, Liang K. A low-cost and hand-hold PCR microdevice based on water-cooling technology. Biomed Microdevices 2023; 25:12. [PMID: 36933064 DOI: 10.1007/s10544-023-00652-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/08/2023] [Indexed: 03/19/2023]
Abstract
Polymerase chain reaction (PCR) has become a powerful tool for detecting various diseases due to its high sensitivity and specificity. However, the long thermocycling time and the bulky system have limited the application of PCR devices in Point-of-care testing. Herein, we have proposed an efficient, low-cost, and hand-hold PCR microdevice, mainly including a control module based on water-cooling technology and an amplification module fabricated by 3D printing. The whole device is tiny and can be easily hand-held with a size of about 110 mm × 100 mm × 40 mm and a weight of about 300 g at a low cost of about $170.83. Based on the water-cooling technology, the device can efficiently perform 30 thermal cycles within 46 min at a heating/cooling rate of 4.0/8.1 ℃/s. To test our instrument, plasmid DNA dilutions were amplified with this device; the results demonstrate successful nucleic acid amplification of the plasmid DNA and exhibit the promise of this device for Point-of-care testing.
Collapse
Affiliation(s)
- Kaixin Sun
- School of Mechanical and Electrical Engineering, Beijing University of Chemical Technology, Beijing, People's Republic of China
| | - Ben Whiteside
- Faculty of Engineering and informatics, University of Bradford, Bradford, UK
| | - Michael Hebda
- Faculty of Engineering and informatics, University of Bradford, Bradford, UK
| | - Yiqiang Fan
- School of Mechanical and Electrical Engineering, Beijing University of Chemical Technology, Beijing, People's Republic of China
| | - Yajun Zhang
- School of Mechanical and Electrical Engineering, Beijing University of Chemical Technology, Beijing, People's Republic of China.
| | - Yumeng Xie
- School of Mechanical and Electrical Engineering, Beijing University of Chemical Technology, Beijing, People's Republic of China
| | - KunMing Liang
- LK Injection Molding Machine Co., LTD, Guangdong, People's Republic of China
| |
Collapse
|
5
|
Qian Y, Brown JB, Zhang T, Huang-Fu ZC, Rao Y. In Situ Detection of Chemical Compositions at Nanodroplet Surfaces and In-Nanodroplet Phases. J Phys Chem A 2022; 126:3758-3764. [PMID: 35667005 DOI: 10.1021/acs.jpca.2c03346] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Small-volume nanodroplets play an increasingly common role in chemistry and biology. Such nanodroplets are believed to have unique chemical and physical properties at the interface between a droplet and its surrounding medium, however, they are underexamined. In this study, we present the novel technique of vibrational sum frequency scattering (VSFS) spectroscopy as an interface-specific, high-performance method for the in situ investigation of nanodroplets with sub-micron radii; as well as the droplet bulk through simultaneous hyper-Raman scattering (HRS) spectroscopy. We use laboratory-generated nanodroplets from aqueous alcohol solutions to demonstrate this technique's ability to separate the vibrational phenomena which take place at droplet surfaces from the underlying bulk phase. In addition, we systemically examine interfacial spectra of nanodroplets containing methanol, ethanol, 1-propanol, and 1-butanol through VSFS. Furthermore, we demonstrate interfacial differences between such nanodroplets and their analogous planar surfaces. The sensitivity of this technique to probe droplet surfaces with few-particle density at standard conditions validates VSFS as an analytical technique for the in situ investigation of small nanodroplets, providing breakthrough information about these species of ever-increasing relevance.
Collapse
Affiliation(s)
- Yuqin Qian
- Department of Chemistry and Biochemistry, Utah State University, Logan, Utah 84322, United States
| | - Jesse B Brown
- Department of Chemistry and Biochemistry, Utah State University, Logan, Utah 84322, United States
| | - Tong Zhang
- Department of Chemistry and Biochemistry, Utah State University, Logan, Utah 84322, United States
| | - Zhi-Chao Huang-Fu
- Department of Chemistry and Biochemistry, Utah State University, Logan, Utah 84322, United States
| | - Yi Rao
- Department of Chemistry and Biochemistry, Utah State University, Logan, Utah 84322, United States
| |
Collapse
|
6
|
Lu YM, Duan YZ, Liu XQ, Chen QD, Sun HB. High-quality rapid laser drilling of transparent hard materials. OPTICS LETTERS 2022; 47:921-924. [PMID: 35167559 DOI: 10.1364/ol.452530] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Accepted: 01/12/2022] [Indexed: 06/14/2023]
Abstract
In this study, a hybrid method for high-quality rapid drilling of transparent hard materials which combines femtosecond laser (fs-laser) Bessel beam modifying materials and selective wet etching is presented. Using this method, micro-holes with no taper of different sizes (from 10 to 35 μm) and shapes (square, triangle, circular, and pentagram) are fabricated. Bessel beams of different lengths can be generated flexibly by loading different computer-generated holograms (CGHs) into the spatial light modulator (SLM) and the maximum length of light interacting with materials can reach 320 μm, leading to a reduction of the laser scanning time by two orders of magnitude. Moreover, a set of three-dimensional multi-layer submicron through-holes in crystal materials is also realized, with an aspect ratio of more than 1000 for each hole. These results indicate that this method has broad application potential in chip packaging, aviation manufacturing, single particle catalysis, and other fields.
Collapse
|