1
|
Bocoum M, Gennisson JL, Venet C, Chi M, Petersen PM, Grabar AA, Ramaz F. Two-color interpolation of the absorption response for quantitative acousto-optic imaging. OPTICS LETTERS 2018; 43:399-402. [PMID: 29400869 DOI: 10.1364/ol.43.000399] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Accepted: 12/13/2017] [Indexed: 06/07/2023]
Abstract
Diffuse optical tomography (DOT) is a reliable and widespread technique for monitoring qualitative changes in absorption inside highly scattering media. It has been shown, however, that acousto-optic (AO) imaging can provide significantly more qualitative information without the need for inversion algorithms due to the spatial resolution afforded by ultrasound probing. In this Letter, we show how, by using multiple-wavelength AO imaging, it is also possible to perform quantitative measurements of absorber concentration inside scattering media.
Collapse
|
2
|
Chandran RS, Sarkar S, Kanhirodan R, Roy D, Vasu RM. Diffusing-wave spectroscopy in an inhomogeneous object: local viscoelastic spectra from ultrasound-assisted measurement of correlation decay arising from the ultrasound focal volume. PHYSICAL REVIEW. E, STATISTICAL, NONLINEAR, AND SOFT MATTER PHYSICS 2014; 90:012303. [PMID: 25122299 DOI: 10.1103/physreve.90.012303] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2014] [Indexed: 06/03/2023]
Abstract
We demonstrate diffusing-wave spectroscopy (DWS) in a localized region of a viscoelastically inhomogeneous object by measurement of the intensity autocorrelation [g(2)(τ)] that captures only the decay introduced by the temperature-induced Brownian motion in the region. The region is roughly specified by the focal volume of an ultrasound transducer which introduces region specific mechanical vibration owing to insonification. Essential characteristics of the localized non-Markovian dynamics are contained in the decay of the modulation depth [M(τ)], introduced by the ultrasound forcing in the focal volume selected, on g(2)(τ). The modulation depth M(τ(i)) at any delay time τ(i) can be measured by short-time Fourier transform of g(2)(τ) and measurement of the magnitude of the spectrum at the ultrasound drive frequency. By following the established theoretical framework of DWS, we are able to connect the decay in M(τ) to the mean-squared displacement (MSD) of scattering centers and the MSD to G*(ω), the complex viscoelastic spectrum. A two-region composite polyvinyl alcohol phantom with different viscoelastic properties is selected for demonstrating local DWS-based recovery of G*(ω) corresponding to these regions from the measured region specific M(τ(i))vsτ(i). The ultrasound-assisted measurement of MSD is verified by simulating, using a generalized Langevin equation (GLE), the dynamics of the particles in the region selected as well as by the usual DWS experiment without the ultrasound. It is shown that whereas the MSD obtained by solving the GLE without the ultrasound forcing agreed with its experimental counterpart covering small and large values of τ, the match was good only in the initial transients in regard to experimental measurements with ultrasound.
Collapse
Affiliation(s)
- R Sriram Chandran
- Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore-560012, India
| | - Saikat Sarkar
- Department of Civil Engineering, Indian Institute of Science, Bangalore-560012, India
| | - Rajan Kanhirodan
- Department of Physics, Indian Institute of Science, Bangalore-560012, India
| | - Debasish Roy
- Department of Civil Engineering, Indian Institute of Science, Bangalore-560012, India
| | - Ram Mohan Vasu
- Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore-560012, India
| |
Collapse
|
3
|
Singh MS, Rajan K, Vasu RM, Roy D. Quantitative estimation of mechanical and optical properties from ultrasound assisted optical tomography data. JOURNAL OF BIOMEDICAL OPTICS 2012; 17:101507. [PMID: 23223983 DOI: 10.1117/1.jbo.17.10.101507] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
We demonstrate quantitative optical property and elastic property imaging from ultrasound assisted optical tomography data. The measurements, which are modulation depth M and phase ϕ of the speckle pattern, are shown to be sensitively dependent on these properties of the object in the insonified focal region of the ultrasound (US) transducer. We demonstrate that Young's modulus (E) can be recovered from the resonance observed in M versus ω (the US frequency) plots and optical absorption (μ(a)) and scattering (μ(s)) coefficients from the measured differential phase changes. All experimental observations are verified also using Monte Carlo simulations.
Collapse
|
4
|
Lai P, Xu X, Wang LV. Ultrasound-modulated optical tomography at new depth. JOURNAL OF BIOMEDICAL OPTICS 2012; 17:066006. [PMID: 22734762 PMCID: PMC3381033 DOI: 10.1117/1.jbo.17.6.066006] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2012] [Revised: 04/06/2012] [Accepted: 04/10/2012] [Indexed: 05/19/2023]
Abstract
Ultrasound-modulated optical tomography (UOT) has the potential to reveal optical contrast deep inside soft biological tissues at an ultrasonically determined spatial resolution. The optical imaging depth reported so far has, however, been limited, which prevents this technique from broader applications. Our latest experimental exploration has pushed UOT to an unprecedented imaging depth. We developed and optimized a UOT system employing a photorefractive crystal-based interferometer. A large aperture optical fiber bundle was used to enhance the efficiencies for diffuse light collection and photorefractive two-wave-mixing. Within the safety limits for both laser illumination and ultrasound modulation, the system has attained the ability to image through a tissue-mimicking phantom of 9.4 cm in thickness, which has never been reached previously by UOT.
Collapse
Affiliation(s)
- Puxiang Lai
- Washington University in St. Louis, Department of Biomedical Engineering, Optical Imaging Laboratory, Campus Box 1097, 1 Brookings Drive, St. Louis, Missouri 63130
| | - Xiao Xu
- Washington University in St. Louis, Department of Biomedical Engineering, Optical Imaging Laboratory, Campus Box 1097, 1 Brookings Drive, St. Louis, Missouri 63130
| | - Lihong V. Wang
- Washington University in St. Louis, Department of Biomedical Engineering, Optical Imaging Laboratory, Campus Box 1097, 1 Brookings Drive, St. Louis, Missouri 63130
- Address all correspondence to: Lihong V. Wang, Washington University in St. Louis, Department of Biomedical Engineering, Optical Imaging Laboratory, Campus Box 1097, 1 Brookings Drive, St. Louis, Missouri 63130. Tel: +314 935 6152; Fax: +314 935 7448; E-mail:
| |
Collapse
|
5
|
Resink SG, Boccara AC, Steenbergen W. State-of-the art of acousto-optic sensing and imaging of turbid media. JOURNAL OF BIOMEDICAL OPTICS 2012; 17:040901. [PMID: 22559674 DOI: 10.1117/1.jbo.17.4.040901] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Acousto-optic (AO) is an emerging hybrid technique for measuring optical contrast in turbid media using coherent light and ultrasound (US). A turbid object is illuminated with a coherent light source leading to speckle formation in the remitted light. With the use of US, a small volume is selected,which is commonly referred to as the "tagging" volume. This volume acts as a source of modulated light, where modulation might involve phase and intensity change. The tagging volume is created by focusing ultrasound for good lateral resolution; the axial resolution is accomplished by making either the US frequency, amplitude, or phase time-dependent. Typical resolutions are in the order of 1 mm. We will concentrate on the progress in the field since 2003. Different schemes will be discussed to detect the modulated photons based on speckle detection, heterodyne detection, photorefractive crystal (PRC) assisted detection, and spectral hole burning (SHB) as well as Fabry-Perot interferometers. The SHB and Fabry-Perot interferometer techniques are insensitive to speckle decorrelation and therefore suitable for in vivo imaging. However, heterodyne and PRC methods also have potential for in vivo measurements. Besides measuring optical properties such as scattering and absorption, AO can be applied in fluorescence and elastography applications.
Collapse
Affiliation(s)
- Steffen G Resink
- MIRA Institute for Biomedical, Technology and Technical Medicine, University of Twente, Biomedical Photonic Imaging Group, P.O. Box 217, 7500 AE Enschede, The Netherlands.
| | | | | |
Collapse
|
6
|
Gunadi S, Leung TS. Spatial sensitivity of acousto-optic and optical near-infrared spectroscopy sensing measurements. JOURNAL OF BIOMEDICAL OPTICS 2011; 16:127005. [PMID: 22191935 DOI: 10.1117/1.3660315] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Near-infrared spectroscopy (NIRS) is a popular sensing technique to measure tissue oxygenation noninvasively. However, the region of interest (ROI) is often beneath a superficial layer, which affects its accuracy. By applying focused ultrasound in the ROI, acousto-optic (AO) techniques can potentially minimize the effect of physiological changes in the superficial layer. Using absorption perturbation experiments in both transmission and reflection modes, we investigated the spatial sensitivity distributions and mean penetration depths of an AO system based on a digital correlator and two popular NIRS systems based on i. intensity measurements using a single source and detector configuration, and ii. spatially resolved spectroscopy. Our results show that for both transmission and reflection modes, the peak relative sensitivities of the two NIRS systems are near to the superficial regions, whereas those of the AO technique are near to the ROIs. In the reflection mode, when the ROI is deeper than 14 mm, the AO technique has a higher absolute mean sensitivity than the two NIRS techniques. As the focused ultrasound is moved deeper into the turbid medium, the mean penetration depth increases accordingly. The focused ultrasound can shift the peak relative sensitivity of the AO measurement toward its focused region.
Collapse
Affiliation(s)
- Sonny Gunadi
- University College London, Department of Medical Physics and Bioengineering, Malet Place Engineering Building, London, WC1E 6BT, United Kingdom
| | | |
Collapse
|
7
|
Chandran RS, Roy D, Kanhirodan R, Vasu RM, Devi CU. Ultrasound modulated optical tomography: Young's modulus of the insonified region from measurement of natural frequency of vibration. OPTICS EXPRESS 2011; 19:22837-22850. [PMID: 22109162 DOI: 10.1364/oe.19.022837] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
We demonstrate a method to recover the Young's modulus (E) of a tissue-mimicking phantom from measurements of ultrasound modulated optical tomography (UMOT). The object is insonified by a dual-beam, confocal ultrasound transducer (US) oscillating at frequencies f₀ and f₀ + Δf and the variation of modulation depth (M) in the autocorrelation of light traversed through the focal region of the US transducer against Δf is measured. From the dominant peaks observed in the above variation, the natural frequencies of the insonified region associated with the vibration along the US transducer axis are deduced. A consequence of the above resonance is that the speckle fluctuation at the resonance frequency has a higher signal-to-noise to ratio (SNR). From these natural frequencies and the associated eigenspectrum of the oscillating object, Young's modulus (E) of the material in the focal region is recovered. The working of this method is confirmed by recovering E in the case of three tissue-mimicking phantoms of different elastic modulus values.
Collapse
Affiliation(s)
- R Sriram Chandran
- Department of Instrumentation and Applied physics, Indian Institute of Science, Bangalore-560012, India
| | | | | | | | | |
Collapse
|
8
|
Murray TW, Lai P, Roy RA. Measuring tissue properties and monitoring therapeutic responses using acousto-optic imaging. Ann Biomed Eng 2011; 40:474-85. [PMID: 22006427 DOI: 10.1007/s10439-011-0425-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2011] [Accepted: 09/29/2011] [Indexed: 11/30/2022]
Abstract
Acousto-optic imaging is a hybrid imaging technique that exploits the interaction between light and sound to image optical contrast at depth in optically turbid media with the high spatial resolution of ultrasound. Quantitative measurement of optical properties using this technique is confounded by multiple parameters that influence the detected acousto-optic signal. In this article, we describe the origin of the acousto-optic response and review techniques that have been proposed to relate this response to the optical properties of turbid media. We present an overview of two acousto-optic sensing approaches. In the first, we demonstrate that the local transport mean free path within turbid media can be obtained by varying the pressure of the ultrasound field and processing the resulting acousto-optic signals. In the second, we demonstrate that the acousto-optic response elicited by a high-intensity ultrasound field during thermal therapy can be used to monitor the onset of lesion formation, ascertain lesion volume, and provide real-time control of exposure duration.
Collapse
Affiliation(s)
- Todd W Murray
- Department of Mechanical Engineering, University of Colorado at Boulder, Boulder, CO, USA.
| | | | | |
Collapse
|
9
|
Elson DS, Li R, Dunsby C, Eckersley R, Tang MX. Ultrasound-mediated optical tomography: a review of current methods. Interface Focus 2011; 1:632-48. [PMID: 22866234 PMCID: PMC3262265 DOI: 10.1098/rsfs.2011.0021] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2011] [Accepted: 05/10/2011] [Indexed: 11/12/2022] Open
Abstract
Ultrasound-mediated optical tomography (UOT) is a hybrid technique that is able to combine the high penetration depth and high spatial resolution of ultrasound imaging to overcome the limits imposed by optical scattering for deep tissue optical sensing and imaging. It has been proposed as a method to detect blood concentrations, oxygenation and metabolism at depth in tissue for the detection of vascularized tumours or the presence of absorbing or scattering contrast agents. In this paper, the basic principles of the method are outlined and methods for simulating the UOT signal are described. The main detection methods are then summarized with a discussion of the advantages and disadvantages of each. The recent focus on increasing the weak UOT signal through the use of the acoustic radiation force is explained, together with a summary of our results showing sensitivity to the mechanical shear stiffness and optical absorption properties of tissue-mimicking phantoms.
Collapse
Affiliation(s)
- Daniel S. Elson
- Department of Surgery and Cancer, Hamlyn Centre for Robotic Surgery, Imperial College London, Exhibition Road, London SW7 2AZ, UK
| | - Rui Li
- Department of Bioengineering, Imperial College London, Exhibition Road, London SW7 2AZ, UK
| | - Christopher Dunsby
- Department of Physics, Imperial College London, Exhibition Road, London SW7 2AZ, UK
| | - Robert Eckersley
- Imaging Sciences Department, Imperial College London, Du Cane Road, London W12 0HS, UK
| | - Meng-Xing Tang
- Department of Bioengineering, Imperial College London, Exhibition Road, London SW7 2AZ, UK
| |
Collapse
|
10
|
Singh MS, Yalavarthy PK, Vasu RM, Rajan K. Assessment of ultrasound modulation of near infrared light on the quantification of scattering coefficient. Med Phys 2010; 37:3744-51. [PMID: 20831082 DOI: 10.1118/1.3456441] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To assess the effect of ultrasound modulation of near infrared (NIR) light on the quantification of scattering coefficient in tissue-mimicking biological phantoms. METHODS A unique method to estimate the phase of the modulated NIR light making use of only time averaged intensity measurements using a charge coupled device camera is used in this investigation. These experimental measurements from tissue-mimicking biological phantoms are used to estimate the differential pathlength, in turn leading to estimation of optical scattering coefficient. A Monte-Carlo model based numerical estimation of phase in lieu of ultrasound modulation is performed to verify the experimental results. RESULTS The results indicate that the ultrasound modulation of NIR light enhances the effective scattering coefficient. The observed effective scattering coefficient enhancement in tissue-mimicking viscoelastic phantoms increases with increasing ultrasound drive voltage. The same trend is noticed as the ultrasound modulation frequency approaches the natural vibration frequency of the phantom material. The contrast enhancement is less for the stiffer (larger storage modulus) tissue, mimicking tumor necrotic core, compared to the normal tissue. CONCLUSIONS The ultrasound modulation of the insonified region leads to an increase in the effective number of scattering events experienced by NIR light, increasing the measured phase, causing the enhancement in the effective scattering coefficient. The ultrasound modulation of NIR light could provide better estimation of scattering coefficient. The observed local enhancement of the effective scattering coefficient, in the ultrasound focal region, is validated using both experimental measurements and Monte-Carlo simulations.
Collapse
|
11
|
Leung TS, Powell S. Fast Monte Carlo simulations of ultrasound-modulated light using a graphics processing unit. JOURNAL OF BIOMEDICAL OPTICS 2010; 15:055007. [PMID: 21054089 DOI: 10.1117/1.3495729] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Ultrasound-modulated optical tomography (UOT) is based on "tagging" light in turbid media with focused ultrasound. In comparison to diffuse optical imaging, UOT can potentially offer a better spatial resolution. The existing Monte Carlo (MC) model for simulating ultrasound-modulated light is central processing unit (CPU) based and has been employed in several UOT related studies. We reimplemented the MC model with a graphics processing unit [(GPU), Nvidia GeForce 9800] that can execute the algorithm up to 125 times faster than its CPU (Intel Core Quad) counterpart for a particular set of optical and acoustic parameters. We also show that the incorporation of ultrasound propagation in photon migration modeling increases the computational time considerably, by a factor of at least 6, in one case, even with a GPU. With slight adjustment to the code, MC simulations were also performed to demonstrate the effect of ultrasonic modulation on the speckle pattern generated by the light model (available as animation). This was computed in 4 s with our GPU implementation as compared to 290 s using the CPU.
Collapse
Affiliation(s)
- Terence S Leung
- University College London, Department of Medical Physics and Bioengineering, Malet Place Engineering Building, London, WC1E 6BT, United Kingdom.
| | | |
Collapse
|
12
|
Bratchenia A, Molenaar R, van Leeuwen TG, Kooyman RPH. Millimeter-resolution acousto-optic quantitative imaging in a tissue model system. JOURNAL OF BIOMEDICAL OPTICS 2009; 14:034031. [PMID: 19566324 DOI: 10.1117/1.3153894] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
We have investigated the application of ultrasound modulated coherent light for quantitative determination of the ratio of dye concentrations and total concentration of absorbers in a blood vessel-mimicking sample. A 3-mm-diam tube containing the mixture of dyes inside an Intralipid-based gel with optical properties similar to tissue was interrogated by two different laser wavelengths in combination with intense microsecond ultrasound bursts. The use of calibration curves allowed us to extract quantitative information on the ratio of dye concentrations with the accuracy of better than 15%, as well as on the total concentration. Furthermore, we demonstrated the feasibility to obtain a quantitative 3-D map of the absorbing structure with a spatial resolution of better than 3 mm. These findings give an outlook to apply this technique for noninvasive 3-D mapping of oxygen saturation and total concentration of hemoglobin in tissue.
Collapse
Affiliation(s)
- Aliaksandr Bratchenia
- University of Twente, Institute of Biomedical Technology, Faculty of Science and Technology, P.O. Box 217, 7500 AE Enschede, The Netherlands.
| | | | | | | |
Collapse
|