1
|
Soomro SR, Sager S, Paniagua-Diaz AM, Prieto PM, Artal P. Head-mounted adaptive optics visual simulator. BIOMEDICAL OPTICS EXPRESS 2024; 15:608-623. [PMID: 38404335 PMCID: PMC10890873 DOI: 10.1364/boe.506858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 12/22/2023] [Accepted: 12/26/2023] [Indexed: 02/27/2024]
Abstract
Adaptive optics visual simulation is a powerful tool for vision testing and evaluation. However, the existing instruments either have fixed tabletop configurations or, being wearable, only offer the correction of defocus. This paper proposes a novel head-mounted adaptive optics visual simulator that can measure and modify complex ocular aberrations in real-time. The prototype is composed of two optical modules, one for the objective assessment of aberrations and the second for wavefront modulation, all of which are integrated into a wearable headset. The device incorporates a microdisplay for stimulus generation, a liquid crystal on silicon (LCoS) spatial light modulator for wavefront manipulation, and a Hartmann-Shack wavefront sensor. Miniature optical components and optical path folding structures, together with in-house 3D printed mounts and housing, were adapted to realize the compact size. The system was calibrated by characterizing and compensating the internal aberrations of the visual relay. The performance of the prototype was analyzed by evaluating the measurement and compensation of low-order and higher-order aberrations induced through trial lenses and phase masks in an artificial eye. The defocus curves for a simulated bifocal diffractive lens were evaluated in real eyes. The results show high accuracy while measuring and compensating for the induced defocus, astigmatism, and higher-order aberrations, whereas the MTF analysis shows post-correction resolution of up to 37.5 cycles/degree (VA 1.25). Moreover, the subjective test results show the defocus curves closely matched to a commercial desktop visual simulator.
Collapse
Affiliation(s)
- Shoaib R. Soomro
- Voptica S.L., Campus de Espinardo (Edificio Pleiades), 30100 Murcia, Spain
- Electronic Engineering Department, Mehran University of Engineering and Technology, Pakistan
| | - Santiago Sager
- Voptica S.L., Campus de Espinardo (Edificio Pleiades), 30100 Murcia, Spain
- Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo (Edificio 34), 30100 Murcia, Spain
| | - Alba M. Paniagua-Diaz
- Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo (Edificio 34), 30100 Murcia, Spain
| | - Pedro M. Prieto
- Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo (Edificio 34), 30100 Murcia, Spain
| | - Pablo Artal
- Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo (Edificio 34), 30100 Murcia, Spain
| |
Collapse
|
2
|
Santiago-Alvarado A, Granados-Agustín FS, López-Raymundo BR, Hernández-Mendez A, Huerta-Carranza O. Development of a bio-inspired optical system that mimics accommodation and lighting regulation like the human eye. APPLIED OPTICS 2024; 63:193-203. [PMID: 38175021 DOI: 10.1364/ao.506986] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Accepted: 12/02/2023] [Indexed: 01/05/2024]
Abstract
Bio-inspired optical systems have recently been developed using polarizers and liquid or rigid lenses. In this work, we propose a bio-inspired opto-mechatronic system that imitates the accommodation and regulation of light intensity as the human eye does. The system uses a polymeric lens as a cornea, an adjustable diaphragm as an iris, a tunable solid elastic lens as a crystalline lens, and a commercial sensor as a retina. We also present the development of the electronic control system to accommodate and regulate the amount of light that enters the system, for which two stepper motors, an Arduino control system, and light and movement sensors are used. The characterization of the system is presented together with the results obtained, where it can be seen that the system works in an acceptable range as the human eye does.
Collapse
|
3
|
Torres-Sepúlveda W, Mira-Agudelo A, Barrera-Ramírez JF, Kolodziejczyk A. Objective method for visual performance prediction. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2023; 40:C138-C149. [PMID: 37132983 DOI: 10.1364/josaa.478022] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
We propose, implement, and validate a new objective method for predicting the trends of visual acuity through-focus curves provided by specific optical elements. The proposed method utilized imaging of sinusoidal gratings provided by the optical elements and the definition of acuity. A custom-made monocular visual simulator equipped with active optics was used to implement the objective method and to validate it via subjective measurements. Visual acuity measurements were obtained monocularly from a set of six subjects with paralyzed accommodation for a naked eye and then that eye compensated by four multifocal optical elements. The objective methodology successfully predicts the trends of the visual acuity through-focus curve for all considered cases. The Pearson correlation coefficient was 0.878 for all tested optical elements, which agrees with results obtained by similar works. The proposed method constitutes an easy and direct alternative technique for the objective testing of optical elements for ophthalmic and optometric applications, which can be implemented before invasive, demanding, or costly procedures on real subjects.
Collapse
|
4
|
Advanced Optical Wavefront Technologies to Improve Patient Quality of Vision and Meet Clinical Requests. Polymers (Basel) 2022; 14:polym14235321. [PMID: 36501713 PMCID: PMC9741482 DOI: 10.3390/polym14235321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 11/28/2022] [Accepted: 12/01/2022] [Indexed: 12/09/2022] Open
Abstract
Adaptive optics (AO) is employed for the continuous measurement and correction of ocular aberrations. Human eye refractive errors (lower-order aberrations such as myopia and astigmatism) are corrected with contact lenses and excimer laser surgery. Under twilight vision conditions, when the pupil of the human eye dilates to 5-7 mm in diameter, higher-order aberrations affect the visual acuity. The combined use of wavefront (WF) technology and AO systems allows the pre-operative evaluation of refractive surgical procedures to compensate for the higher-order optical aberrations of the human eye, guiding the surgeon in choosing the procedure parameters. Here, we report a brief history of AO, starting from the description of the Shack-Hartmann method, which allowed the first in vivo measurement of the eye's wave aberration, the wavefront sensing technologies (WSTs), and their principles. Then, the limitations of the ocular wavefront ascribed to the IOL polymeric materials and design, as well as future perspectives on improving patient vision quality and meeting clinical requests, are described.
Collapse
|
5
|
Lago CM, de Castro A, Benedí-García C, Aissati S, Marcos S. Evaluating the effect of ocular aberrations on the simulated performance of a new refractive IOL design using adaptive optics. BIOMEDICAL OPTICS EXPRESS 2022; 13:6682-6694. [PMID: 36589555 PMCID: PMC9774854 DOI: 10.1364/boe.473573] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 10/30/2022] [Accepted: 11/01/2022] [Indexed: 05/02/2023]
Abstract
Adaptive optics (AO) visual simulators are excellent platforms for non-invasive simulation visual performance with new intraocular lens (IOL) designs, in combination with a subject own ocular aberrations and brain. We measured the through focus visual acuity in subjects through a new refractive IOL physically inserted in a cuvette and projected onto the eye's pupil, while aberrations were manipulated (corrected, or positive/negative spherical aberration added) using a deformable mirror (DM) in a custom-developed AO simulator. The IOL increased depth-of-focus (DOF) to 1.53 ± 0.21D, while maintaining high Visual Acuity (VA, -0.07 ± 0.05), averaged across subjects and conditions. Modifying the aberrations did not alter IOL performance on average.
Collapse
Affiliation(s)
- Carmen M. Lago
- Visual Optics and Biophotonics Laboratory, Instituto de Óptica, Consejo Superior de Investigaciones Científicas, Calle Serrano 121, Madrid, 28006, Spain
- 2EyesVision S.L., Plaza de la Encina 10, Madrid, 28760, Spain
| | - Alberto de Castro
- Visual Optics and Biophotonics Laboratory, Instituto de Óptica, Consejo Superior de Investigaciones Científicas, Calle Serrano 121, Madrid, 28006, Spain
| | - Clara Benedí-García
- Visual Optics and Biophotonics Laboratory, Instituto de Óptica, Consejo Superior de Investigaciones Científicas, Calle Serrano 121, Madrid, 28006, Spain
| | - Sara Aissati
- Visual Optics and Biophotonics Laboratory, Instituto de Óptica, Consejo Superior de Investigaciones Científicas, Calle Serrano 121, Madrid, 28006, Spain
- Center for Visual Sciences; The Institute of Optics and Flaum Eye Institute, University of Rochester,14642, New York, USA
| | - Susana Marcos
- Visual Optics and Biophotonics Laboratory, Instituto de Óptica, Consejo Superior de Investigaciones Científicas, Calle Serrano 121, Madrid, 28006, Spain
- Center for Visual Sciences; The Institute of Optics and Flaum Eye Institute, University of Rochester,14642, New York, USA
| |
Collapse
|
6
|
Marcos S, Artal P, Atchison DA, Hampson K, Legras R, Lundström L, Yoon G. Adaptive optics visual simulators: a review of recent optical designs and applications [Invited]. BIOMEDICAL OPTICS EXPRESS 2022; 13:6508-6532. [PMID: 36589577 PMCID: PMC9774875 DOI: 10.1364/boe.473458] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Revised: 10/26/2022] [Accepted: 10/27/2022] [Indexed: 05/02/2023]
Abstract
In their pioneering work demonstrating measurement and full correction of the eye's optical aberrations, Liang, Williams and Miller, [JOSA A14, 2884 (1997)10.1364/JOSAA.14.002884] showed improvement in visual performance using adaptive optics (AO). Since then, AO visual simulators have been developed to explore the spatial limits to human vision and as platforms to test non-invasively optical corrections for presbyopia, myopia, or corneal irregularities. These applications have allowed new psychophysics bypassing the optics of the eye, ranging from studying the impact of the interactions of monochromatic and chromatic aberrations on vision to neural adaptation. Other applications address new paradigms of lens designs and corrections of ocular errors. The current paper describes a series of AO visual simulators developed in laboratories around the world, key applications, and current trends and challenges. As the field moves into its second quarter century, new available technologies and a solid reception by the clinical community promise a vigorous and expanding use of AO simulation in years to come.
Collapse
Affiliation(s)
- Susana Marcos
- Center for Visual Sciences; The Institute of Optics and Flaum Eye Institute, University of Rochester, New York 14642, USA
| | - Pablo Artal
- Laboratorio de Optica, Universidad de Murcia, Campus Universitario de Espinardo, 30100, Spain
| | - David A. Atchison
- Centre for Vision and Eye Research, Queensland University of Technology, Brisbane Q, 4059, Australia
| | - Karen Hampson
- Department of Optometry, University of Manchester, Manchester M13 9PL, UK
| | - Richard Legras
- LuMIn, CNRS, ENS Paris-Saclay, Université Paris-Saclay, CentraleSupelec, Université Paris-Saclay Orsay, 91400, France
| | - Linda Lundström
- KTH (Royal Institute of Technology), Stockholm, 10691, Sweden
| | - Geunyoung Yoon
- College of Optometry, University of Houston, Houston, 77004, USA
| |
Collapse
|
7
|
Vedhakrishnan S, de Castro A, Vinas M, Aissati S, Marcos S. Accommodation through simulated multifocal optics. BIOMEDICAL OPTICS EXPRESS 2022; 13:6695-6710. [PMID: 36589586 PMCID: PMC9774842 DOI: 10.1364/boe.473595] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Revised: 10/26/2022] [Accepted: 10/27/2022] [Indexed: 05/02/2023]
Abstract
We evaluated the interaction of multifocal patterns with eye's accommodation. Seven patterns were mapped on the spatial light modulator and the deformable mirror of an adaptive optics visual simulator, and projected onto the subjects' eyes, representing different contact lens designs: NoLens, Bifocal Center Distance (+2.50D), Bifocal Center Near (+2.50D) and Multifocal Center Near-MediumAdd (+1.75D) and Center Near HighAdd (+2.50D), positive and negative spherical aberration (±1µm). The change in spherical aberration and the accommodative response to accommodative demands were obtained from Hartmann-Shack measurements. Positive spherical aberration and Center Distance designs are consistent with a higher accommodative response (p=0.001 & p=0.003): steeper shift of SA towards negative values and lower accommodative lag.
Collapse
Affiliation(s)
- Shrilekha Vedhakrishnan
- Instituto de Optica ”Daza de Valdes”, Consejo Superior de Investigaciones Cientificas, IO-CSIC, Serrano, 121, Madrid 28006, Spain
| | - Alberto de Castro
- Instituto de Optica ”Daza de Valdes”, Consejo Superior de Investigaciones Cientificas, IO-CSIC, Serrano, 121, Madrid 28006, Spain
| | - Maria Vinas
- Wellman Center for Photomedicine and Harvard Medical school, Massachusetts General Hospital, 50 Blossom St, Boston, MA, USA
| | - Sara Aissati
- Center for Visual Science; The Institute of Optics; Flaum Eye Institute, University of Rochester, Rochester, New York, USA
| | - Susana Marcos
- Instituto de Optica ”Daza de Valdes”, Consejo Superior de Investigaciones Cientificas, IO-CSIC, Serrano, 121, Madrid 28006, Spain
- Center for Visual Science; The Institute of Optics; Flaum Eye Institute, University of Rochester, Rochester, New York, USA
| |
Collapse
|
8
|
In Vitro Optical Performance of Multifocal and Extended Depth-of-Focus Intraocular Lenses in Spherical Aberration Conditions. J Cataract Refract Surg 2021; 48:616-622. [PMID: 34840253 DOI: 10.1097/j.jcrs.0000000000000869] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Accepted: 11/17/2021] [Indexed: 11/26/2022]
Abstract
ABSTRACT PurposeTo evaluate and compare the optical performances of 4 different types of intraocular lenses (IOLs) in various spherical aberration (SA) conditions.SettingPOSTECH, Pohang, Republic of Korea.DesignIn vitro laboratory study.MethodsA custom optical bench system with adaptive optics (AO) was used. A monofocal IOL, a bifocal IOL, a trifocal IOL, and an extended depth-of-focus (EDOF) IOL from the Zeiss were evaluated by measuring through-focus modulation transfer function (MTF) as a function of vergence. MTF changes with SA from -0.1μm to +0.1μm with 0.05μm step size were analyzed and compared.ResultsIn aberration free condition, the 4 IOLs showed different MTF curves consistent with their designs In SA conditions, all the IOLs showed MTF value decreases and the decrease rates at the far focus varied from 28% to 38% per 0.1μm SAs. The trifocal IOL had low MTF values at the intermediate focus in the noise level with ±0.1μm SAs.ConclusionsAll the tested IOLs showed MTF decreases with SA in different levels. The trifocal and EDOF IOLs were the most and least sensitive to SA among the evaluated IOLs. The study results might be useful in the selection of IOLs for cataract patients with SAs.
Collapse
|
9
|
Benedi-Garcia C, Vinas M, Lago CM, Aissati S, de Castro A, Dorronsoro C, Marcos S. Optical and visual quality of real intraocular lenses physically projected on the patient's eye. BIOMEDICAL OPTICS EXPRESS 2021; 12:6360-6374. [PMID: 34745742 PMCID: PMC8548014 DOI: 10.1364/boe.432578] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 08/11/2021] [Accepted: 08/11/2021] [Indexed: 05/06/2023]
Abstract
Visual simulators aim at evaluating vision with ophthalmic corrections prior to prescription or implantation of intraocular lenses (IOLs) in the patient's eye. In the present study, we present the design, implementation, and validation of a new IOL-in-cuvette channel in an Adaptive Optics visual simulator, which provides an alternative channel for pre-operative simulation of vision with IOLs. The IOL is projected on the pupil's plane of the subject by using a Rassow system. A second lens, the Rassow lens, compensates for an IOL of 20 D while other powers can be corrected with a Badal system within a 5 D range. The new channel was evaluated by through-focus (TF) optical quality in an artificial eye on bench, and by TF visual acuity in patients, with various IOL designs (monofocal, diffractive trifocal, and refractive extended depth of focus).
Collapse
Affiliation(s)
- Clara Benedi-Garcia
- Institute of Optics, Spanish National Research Council, IO-CSIC, Madrid, Spain
| | - Maria Vinas
- Institute of Optics, Spanish National Research Council, IO-CSIC, Madrid, Spain
- Currently with Wellman Center for Photomedicine, Massachusetts General Hospital Harvard Medical School, Boston, MA, USA
| | - Carmen M Lago
- Institute of Optics, Spanish National Research Council, IO-CSIC, Madrid, Spain
- 2EyesVision, Madrid, Spain
| | - Sara Aissati
- Institute of Optics, Spanish National Research Council, IO-CSIC, Madrid, Spain
| | - Alberto de Castro
- Institute of Optics, Spanish National Research Council, IO-CSIC, Madrid, Spain
| | - Carlos Dorronsoro
- Institute of Optics, Spanish National Research Council, IO-CSIC, Madrid, Spain
- 2EyesVision, Madrid, Spain
| | - Susana Marcos
- Institute of Optics, Spanish National Research Council, IO-CSIC, Madrid, Spain
- Center for Visual Sciences, The Institute of Optics, Flaum Eye Institute, University of Rochester, Rochester, NY 14642, USA
| |
Collapse
|
10
|
Kovacevich DA, Ma T, Gamboa AR, Nitzsche MP, Saro-Cortes V, Davis E, Singer JP. Thermocapillary dewetting-based dynamic spatial light modulator. OPTICS LETTERS 2021; 46:3721-3724. [PMID: 34329265 DOI: 10.1364/ol.429994] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Accepted: 07/02/2021] [Indexed: 06/13/2023]
Abstract
Dynamic spatial light modulators (SLMs) are capable of precisely modulating a beam of light by tuning the phase or intensity of an array of pixels in parallel. They can be utilized in applications ranging from image projection to beam front aberration and microscopic particle manipulation with optical tweezers. However, conventional dynamic SLMs are typically incompatible with high-power sources, as they contain easily damaged optically absorbing components. To address this, we present an SLM that utilizes a viscous film with a local thickness controlled via thermocapillary dewetting. The film is reflowable and can cycle through different patterns, representing, to the best of our knowledge, the first steps towards a dynamic optical device based on the thermocapillary dewetting mechanism.
Collapse
|
11
|
Ng CJ, Blake R, Banks MS, Tadin D, Yoon G. Optics and neural adaptation jointly limit human stereovision. Proc Natl Acad Sci U S A 2021; 118:e2100126118. [PMID: 34074775 PMCID: PMC8201763 DOI: 10.1073/pnas.2100126118] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Stereovision is the ability to perceive fine depth variations from small differences in the two eyes' images. Using adaptive optics, we show that even minute optical aberrations that are not clinically correctable, and go unnoticed in everyday vision, can affect stereo acuity. Hence, the human binocular system is capable of using fine details that are not experienced in everyday vision. Interestingly, stereo acuity varied considerably across individuals even when they were provided identical perfect optics. We also found that individuals' stereo acuity is better when viewing with their habitual optics rather than someone else's (better) optics. Together, these findings suggest that the visual system compensates for habitual optical aberrations through neural adaptation and thereby optimizes stereovision uniquely for each individual. Thus, stereovision is limited by small optical aberrations and by neural adaptation to one's own optics.
Collapse
Affiliation(s)
- Cherlyn J Ng
- Flaum Eye Institute, University of Rochester, Rochester, NY 14642
- Center for Visual Science, University of Rochester, Rochester, NY 14627
| | - Randolph Blake
- Department of Psychology, Vanderbilt University, Nashville, TN 37203
| | - Martin S Banks
- School of Optometry, University of California, Berkeley, CA 94720;
| | - Duje Tadin
- Flaum Eye Institute, University of Rochester, Rochester, NY 14642
- Center for Visual Science, University of Rochester, Rochester, NY 14627
- Department of Brain and Cognitive Sciences, University of Rochester, Rochester, NY 14627
| | - Geunyoung Yoon
- Flaum Eye Institute, University of Rochester, Rochester, NY 14642;
- Center for Visual Science, University of Rochester, Rochester, NY 14627
| |
Collapse
|
12
|
Marcos S, Martinez-Enriquez E, Vinas M, de Castro A, Dorronsoro C, Bang SP, Yoon G, Artal P. Simulating Outcomes of Cataract Surgery: Important Advances in Ophthalmology. Annu Rev Biomed Eng 2021; 23:277-306. [PMID: 33848431 DOI: 10.1146/annurev-bioeng-082420-035827] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
As the human eye ages, the crystalline lens stiffens (presbyopia) and opacifies (cataract), requiring its replacement with an artificial lens [intraocular lens (IOL)]. Cataract surgery is the most frequently performed surgical procedure in the world. The increase in IOL designs has not been paralleled in practice by a sophistication in IOL selection methods, which rely on limited anatomical measurements of the eye and the surgeon's interpretation of the patient's needs and expectations. We propose that the future of IOL selection will be guided by 3D quantitative imaging of the crystalline lens to map lens opacities, anticipate IOL position, and develop fully customized eye models for ray-tracing-based IOL selection. Conversely, visual simulators (in which IOL designs are programmed in active elements) allow patients to experience prospective vision before surgery and to make more informed decisions about which IOL to choose. Quantitative imaging and optical and visual simulations of postsurgery outcomes will allow optimal treatments to be selected for a patient undergoing modern cataract surgery.
Collapse
Affiliation(s)
- Susana Marcos
- Instituto de Óptica "Daza de Valdés," Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid 28006, Spain;
| | - Eduardo Martinez-Enriquez
- Instituto de Óptica "Daza de Valdés," Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid 28006, Spain;
| | - Maria Vinas
- Instituto de Óptica "Daza de Valdés," Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid 28006, Spain;
| | - Alberto de Castro
- Instituto de Óptica "Daza de Valdés," Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid 28006, Spain;
| | - Carlos Dorronsoro
- Instituto de Óptica "Daza de Valdés," Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid 28006, Spain; .,2EyesVision, Madrid 28760, Spain
| | - Seung Pil Bang
- Flaum Eye Institute, The Institute of Optics, Center for Visual Science, Department of Biomedical Engineering, University of Rochester, Rochester, New York 14632, USA
| | - Geunyoung Yoon
- Flaum Eye Institute, The Institute of Optics, Center for Visual Science, Department of Biomedical Engineering, University of Rochester, Rochester, New York 14632, USA
| | - Pablo Artal
- Laboratorio de Óptica, Universidad de Murcia, Murcia 30100, Spain
| |
Collapse
|
13
|
Tabernero J, Otero C, Pardhan S. A Comparison Between Refraction From an Adaptive Optics Visual Simulator and Clinical Refractions. Transl Vis Sci Technol 2020; 9:23. [PMID: 32832229 PMCID: PMC7414619 DOI: 10.1167/tvst.9.7.23] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Accepted: 04/14/2020] [Indexed: 11/24/2022] Open
Abstract
Purpose The Visual Adaptive Optics (VAO) is an adaptive optics visual simulator with an embedded Hartmann–Shack aberrometer that can give objective and subjective refraction measures. The aim of the present study was to compare the findings of the objective and subjective refractions from the VAO with a commercial autorefractometer (Topcon Corp., Tokyo, Japan) and a subjective refraction by an optometrist. The influence of age, refractive error type, and presence of ocular diseases was ascertained. Methods The refractive error was obtained in 469 participants using the four techniques mentioned. Data were analyzed with power vectors mean spherical equivalent, the vertical Jackson-Cross-Cylinder, and the oblique Jackson-Cross-Cylinder. Age, refractive error type (myopia, emmetropia, hyperopia) and presence of ocular diseases (yes, no) were included as covariates. Agreement was assessed using the 95% interval of agreement. Results The median spherical equivalent difference and the interval of agreement for all the participants with the VAO subjective, VAO objective, and autorefraction with the clinical subjective refraction were (+0.13, 1.80 diopters [D]), (+0.38, 1.80 D), and (−0.38, 2.10 D), respectively. When considering only healthy participants, the results were (+0.06, 1.70 D), (+0.38, 1.60 D) and (−0.25, 1.80 D), respectively. When considering only those participants with any ocular condition, the results with VAO subjective, VAO objective and autorefraction were (+0.13, 2.50 D), (+0.31, 2.70 D), and (−0.50, 4.80 D), respectively. Conclusions The VAO subjective refraction is more accurate than VAO objective refraction and autorefraction, regardless of refractive error, age, or the presence of ocular conditions. The presence of ocular conditions significantly deteriorates the accuracy of all refraction methods. Translational Relevance Reported clinical comparisons between different types of standard refraction methods and a new adaptive optics refraction instrument (VAO) are in good agreement and support the further development of this method to increase refraction accuracy and to refract quicker than standard procedures.
Collapse
Affiliation(s)
- Juan Tabernero
- Vision and Eye Research Institute, School of Medicine, Anglia Ruskin University, Cambridge, UK.,Departamento de Electromagnetismo y Electrónica, Facultad de Química, Universidad de Murcia, Murcia, Spain
| | - Carles Otero
- Vision and Eye Research Institute, School of Medicine, Anglia Ruskin University, Cambridge, UK
| | - Shahina Pardhan
- Vision and Eye Research Institute, School of Medicine, Anglia Ruskin University, Cambridge, UK
| |
Collapse
|
14
|
Akondi V, Dubra A. Average gradient of Zernike polynomials over polygons. OPTICS EXPRESS 2020; 28:18876-18886. [PMID: 32672177 PMCID: PMC7340383 DOI: 10.1364/oe.393223] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Revised: 05/03/2020] [Accepted: 05/25/2020] [Indexed: 05/23/2023]
Abstract
Wavefront estimation from slope sensor data is often achieved by fitting measured slopes with Zernike polynomial derivatives averaged over the sampling subapertures. Here we discuss how the calculation of these average derivatives can be reduced to one-dimensional integrals of the Zernike polynomials, rather than their derivatives, along the perimeter of each subaperture. We then use this result to derive closed-form expressions for the average Zernike polynomial derivatives over polygonal areas, only requiring evaluation of polynomials at the polygon vertices. Finally, these expressions are applied to simulated Shack-Hartmann wavefront sensors with 7 and 23 fully illuminated lenslets across a circular pupil, with their accuracy and calculation time compared against commonly used integration methods.
Collapse
|
15
|
Bifocal and Multifocal Contact Lenses for Presbyopia and Myopia Control. J Ophthalmol 2020; 2020:8067657. [PMID: 32318285 PMCID: PMC7152962 DOI: 10.1155/2020/8067657] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Revised: 02/10/2020] [Accepted: 02/24/2020] [Indexed: 02/07/2023] Open
Abstract
Bifocal and multifocal optical devices are intended to get images into focus from objects placed at different distances from the observer. Spectacles, contact lenses, and intraocular lenses can meet the requirements to provide such a solution. Contact lenses provide unique characteristics as a platform for implementing bifocality and multifocality. Compared to spectacles, they are closer to the eye, providing a wider field of view, less distortion, and their use is more consistent as they are not so easily removed along the day. In addition, contact lenses are also minimally invasive, can be easily exchangeable, and, therefore, suitable for conditions in which surgical procedures are not indicated. Contact lenses can remain centered with the eye despite eye movements, providing the possibility for simultaneous imaging from different object distances. The main current indications for bifocal and multifocal contact lenses include presbyopia correction in adult population and myopia control in children. Considering the large numbers of potential candidates for optical correction of presbyopia and the demographic trends in myopia, the potential impact of contact lenses for presbyopia and myopia applications is undoubtedly tremendous. However, the ocular characteristics and expectations vary significantly between young and older candidates and impose different challenges in fitting bifocal and multifocal contact lenses for the correction of presbyopia and myopia control. This review presents the recent developments in material platforms, optical designs, simulated visual performance, and the clinical performance assessment of bifocal and multifocal contact lenses for presbyopia correction and/or myopia progression control.
Collapse
|
16
|
Vinas M, Aissati S, Romero M, Benedi-Garcia C, Garzon N, Poyales F, Dorronsoro C, Marcos S. Pre-operative simulation of post-operative multifocal vision. BIOMEDICAL OPTICS EXPRESS 2019; 10:5801-5817. [PMID: 31799048 PMCID: PMC6865107 DOI: 10.1364/boe.10.005801] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Revised: 09/22/2019] [Accepted: 09/22/2019] [Indexed: 05/06/2023]
Abstract
While multifocal intraocular lenses (MIOLs) are increasingly implanted to correct for presbyopia, how one sees with a multifocal correction is hard to explain and imagine. The current study evaluates the quality of various visual simulating technologies by comparing vision with simulated MIOLs pre-operatively and the implanted MIOLs post-operatively in the same patients. Two simulation platforms were used: (1) a custom-developed adaptiveoptics (AO) system, with two visual simulator devices: a spatial light modulator (SLM) and an optotunable lens operating under temporal multiplexing (SimVis); and (2) a wearable, binocular, large field of view SimVis2Eyes clinical simulator (SimVis Gekko, 2Eyes Vision, Madrid, Spain). All devices were programmed to simulate a trifocal diffractive MIOL (POD F, FineVision, PhysIOL). Eight patients were measured pre-operatively simulating the trifocal lens and post-operatively with implantation of the same MIOL. Through-focus decimal visual acuity (TF VA) was measured (1) monocularly in monochromatic light using a four-alternative-forced-choice procedure in the AO system; and (2) binocularly using a clinical optotype in white light. Visual simulations pre-operatively predict well the TF VA performance found post-operatively in patients implanted with the real IOL. The average RMS difference between TF curves with the different visual simulators was 0.05 ± 0.01. The average RMS difference between the TF VA curves with the SimVis pre-operatively and the real MIOL post-operatively was 0.06 ± 0.01 in both platforms, and it was higher in cataract eyes (0.08 ± 0.01, on average across simulators) than in eyes with clear lens. In either group the shape of the TF curves is similar across simulators and pre- and post-operatively. TF curves cross-correlated significantly between simulators (lag k = 0, rho = 0.889), as well as with results with the real MIOL implanted (lag k = 0, rho = 0.853). Visual simulations are useful programmable tools to predict visual performance with MIOLs, both in an AO environment and in a clinical simulator. Pre-operative visual simulations and post-operative data are in good agreement.
Collapse
Affiliation(s)
- Maria Vinas
- Institute of Optics, Spanish National Research Council, IO-CSIC, Serrano, 121, Madrid 28006, Spain
| | | | - Mercedes Romero
- Institute of Optics, Spanish National Research Council, IO-CSIC, Serrano, 121, Madrid 28006, Spain
| | - Clara Benedi-Garcia
- Institute of Optics, Spanish National Research Council, IO-CSIC, Serrano, 121, Madrid 28006, Spain
| | | | | | - Carlos Dorronsoro
- Institute of Optics, Spanish National Research Council, IO-CSIC, Serrano, 121, Madrid 28006, Spain
| | - Susana Marcos
- Institute of Optics, Spanish National Research Council, IO-CSIC, Serrano, 121, Madrid 28006, Spain
| |
Collapse
|
17
|
Akondi V, Dubra A. Accounting for focal shift in the Shack-Hartmann wavefront sensor. OPTICS LETTERS 2019; 44:4151-4154. [PMID: 31465350 PMCID: PMC7535119 DOI: 10.1364/ol.44.004151] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2019] [Accepted: 07/13/2019] [Indexed: 05/18/2023]
Abstract
The Shack-Hartmann wavefront sensor samples a beam of light using an array of lenslets, each of which creates an image onto a pixelated sensor. These images translate from their nominal position by a distance proportional to the average wavefront slope over the corresponding lenslet. This principle fails in partially and/or non-uniformly illuminated lenslets when the lenslet array is focused to maximize peak intensity, leading to image centroid bias. Here, we show that this bias is due to the low Fresnel number of the lenslets, which shifts the diffraction focus away from the geometrical focus. We then demonstrate how the geometrical focus can be empirically found by minimizing the bias in partially illuminated lenslets.
Collapse
Affiliation(s)
- Vyas Akondi
- Byers Eye Institute, Stanford University, Palo Alto, California 94303, USA
| | - Alfredo Dubra
- Byers Eye Institute, Stanford University, Palo Alto, California 94303, USA
| |
Collapse
|
18
|
Radhakrishnan A, Pascual D, Marcos S, Dorronsoro C. Vision with different presbyopia corrections simulated with a portable binocular visual simulator. PLoS One 2019; 14:e0221144. [PMID: 31430328 PMCID: PMC6701771 DOI: 10.1371/journal.pone.0221144] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2019] [Accepted: 07/31/2019] [Indexed: 11/18/2022] Open
Abstract
Presbyopes can choose today among different corrections to provide them with functional vision at far and near, and the outcomes and patient satisfaction depend on the selection. In this study, we present a binocular and portable vision simulator, based on temporal multiplexing of two synchronized tunable lenses allowing see-through and programmable visual simulations of presbyopic corrections. Seventeen binocular corrections were tested: 3 Monofocal (Far, Intermediate, Near), 4 Simultaneous Vision (bifocal, trifocal), 2 Monovision (far and near in either eye) and 8 Modified Monovision corrections (Simultaneous vision in one eye, Monofocal in the other eye). Perceived visual quality was assessed through the simulated corrections in 8 cyclopleged subjects who viewed a composite realistic visual scene with high contrast letters and a landscape at far (4 m) and a high contrast text at intermediate (66 cm) and near (33 cm) distances. Perceptual scores were obtained on a scale of 0 to 5 (low to high perceived quality). Perceptual preference was assessed by judging 36 random image pairs (6 repetitions) viewed through 9 binocular presbyopic corrections using two-interval forced choice procedures. The average score, across far and near distances, was the highest for Monovision (4.4±0.3), followed by Modified Monovision (3.4±0.1), Simultaneous Vision (3.0±0.1) and Monofocal corrections (2.9±0.2). However, the mean difference between far and near was lower for Simultaneous Vision and Monovision (0.4±0.1 PS) than Modified Monovision (1.8±0.7) or monofocal corrections (3.3±1.5). A strong significant correlation was found between the perceptual scores and the percentages of energy in focus, for each correction and distance (R = 0.64, p<0.0001). Multivariate ANOVA revealed significant influence of observation distances (p<10-9) and patients (p = 0.01) on Perceptual Score. In conclusion, we have developed a binocular portable vision simulator that can simulate rapidly and non-invasively different combinations of presbyopic corrections. This tool has applications in systematic clinical evaluation of presbyopia corrections.
Collapse
Affiliation(s)
- Aiswaryah Radhakrishnan
- Laboratory of Visual Optics and Biophotonics, Instituto de Óptica, IO-CSIC, Consejo Superior de Investigaciones Científicas, Madrid, Spain
| | - Daniel Pascual
- Laboratory of Visual Optics and Biophotonics, Instituto de Óptica, IO-CSIC, Consejo Superior de Investigaciones Científicas, Madrid, Spain
| | - Susana Marcos
- Laboratory of Visual Optics and Biophotonics, Instituto de Óptica, IO-CSIC, Consejo Superior de Investigaciones Científicas, Madrid, Spain
| | - Carlos Dorronsoro
- Laboratory of Visual Optics and Biophotonics, Instituto de Óptica, IO-CSIC, Consejo Superior de Investigaciones Científicas, Madrid, Spain
- * E-mail:
| |
Collapse
|
19
|
Suchkov N, Fernández EJ, Artal P. Wide-range adaptive optics visual simulator with a tunable lens. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2019; 36:722-730. [PMID: 31044998 DOI: 10.1364/josaa.36.000722] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
An adaptive optics visual simulator (AOVS) with an extended dioptric range was developed, allowing measuring and correcting aberrations in a majority of highly ametropic eyes. In the instrument, a tunable lens is used for defocus correction, while a liquid-crystal-on-silicon spatial light modulator is used for compensating or inducing any other aberration. The instrument incorporates a digital projector, which uses a micromirror array to display the stimuli. A motorized diaphragm enables operation for any physiological pupil size. A full description of the instrument and its calibration are provided, together with the results obtained in seven highly myopic subjects with refraction of -7.2±1.8 D (mean±SD). Refraction obtained with the instrument was compared to the standard refraction prescribed by trial lenses. When using the refraction obtained by the AOVS, the visual acuity (VA) exhibited an average increase of 0.21 (decimal scale). The visual impact of correcting high-order aberrations is presented in three subjects, whose VAs slightly improved with the correction. High myopes are able to benefit from the improved refraction assessment. The new instrument creates a possibility for a wide number of new experiments, especially for eyes exhibiting large refractive errors, where previous AO instruments failed to operate.
Collapse
|
20
|
Suchkov N, Fernández EJ, Martínez-Fuentes JL, Moreno I, Artal P. Simultaneous aberration and aperture control using a single spatial light modulator. OPTICS EXPRESS 2019; 27:12399-12413. [PMID: 31052780 DOI: 10.1364/oe.27.012399] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Accepted: 03/21/2019] [Indexed: 06/09/2023]
Abstract
A method to simultaneously control aberrations and the aperture of an optical system using a single phase-only spatial light modulator was investigated. The experiment was performed using a liquid-crystal-on-silicon spatial light modulator (LCoS-SLM) within an adaptive optics system used for visual testing, although the method has broader applications in adaptive optics field. The performance of the technique was characterized through the estimation of the system's modulation transfer functions (MTFs) by using a random chart method. MTFs obtained from the phase modulation-based approach were compared with those from using a real aperture (diaphragm). The areas under the MTFs for the two conditions were similar up to 98%, confirming that the low-pass filter effect associated to the size of the entrance pupil was similar for the phase-modulated pupil and the physical pupil. As an example of application, both aberrations and pupil were controlled by a single phase-only modulator to study the through-focus visual performance in real subjects. Limitations and possible enhancements of the presented method were also discussed. The presented technique reduces complexity and cost of adaptive optics systems. It opens the door to new experiments by allowing dynamic modulation of aberrations and apertures of any shape.
Collapse
|
21
|
Shetty R, Kochar S, Grover T, Khamar P, Kusumgar P, Sainani K, Sinha Roy A. Repeatability of a Commercially Available Adaptive Optics Visual Simulator and Aberrometer in Normal and Keratoconic Eyes. J Refract Surg 2018; 33:769-772. [PMID: 29117417 DOI: 10.3928/1081597x-20170718-02] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2017] [Accepted: 07/14/2017] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the repeatability of aberration measurement obtained by a Hartmann-Shack aberrometer combined with a visual adaptive optics simulator in normal and keratoconic eyes. METHODS One hundred fifteen normal eyes and 92 eyes with grade I and II keratoconus, as per the Amsler-Krumeich classification, were included in the study. To evaluate the repeatability, three consecutive measurements of ocular aberrations were obtained by a single operator. Zernike analyses up to the 5th order for a pupil size of 4.5 mm were performed. Statistical analyses included the intraclass correlation coefficient (ICC) and within-subject standard deviation (SD). RESULTS For intrasession repeatability, the ICC value for sphere and cylinder was 0.94 and 0.93 in normal eyes and 0.98 and 0.97 in keratoconic eyes, respectively. The ICC for root mean square of higher order aberrations (HOARMS) was 0.82 in normal and 0.98 in keratoconic eyes. For 3rd order aberrations (trefoil and coma), the ICC values were greater than 0.87 for normal eyes and greater than 0.92 for keratoconic eyes. The ICC for spherical aberration was 0.92 and 0.90 in normal and keratoconic eyes, respectively. CONCLUSIONS Visual adaptive optics provided repeatable aberrometry data in both normal and keratoconic eyes. For most of the parameters, the repeatability in eyes with early keratoconus was somewhat better than that for normal eyes. The repeatability of the Zernike terms was acceptable for 3rd order (trefoil and coma) and spherical aberrations. Therefore, visual adaptive optics was a suitable tool to perform repeatable aberrometric measurements. [J Refract Surg. 2017;33(11):769-772.].
Collapse
|
22
|
Liquid Crystal Spatial Light Modulators for Simulating Zonal Multifocal Lenses. Optom Vis Sci 2017; 94:867-875. [DOI: 10.1097/opx.0000000000001108] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
23
|
Martinez JL, Fernandez EJ, Prieto PM, Artal P. Chromatic aberration control with liquid crystal spatial phase modulators. OPTICS EXPRESS 2017; 25:9793-9801. [PMID: 28468359 DOI: 10.1364/oe.25.009793] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
The chromatic behavior of diffractive optical elements, exhibiting 2π-wrapped phase profiles, implemented into liquid crystal spatial light modulators (LC-SLM) is described. A wrapped phase map is only equivalent to the original continuous profile for the design wavelength while at other wavelengths there are unwanted phase jumps and the profile does not correspond to a pure defocus. For those conditions the wrapped profile behaves as a multiple order lens (multi-focal lens). The optical power dispersion for each order is linearly proportional to the wavelength, while the energy of each order depends on the design wavelength and the material dispersion. For practical purposes, for most of the visible range only first order (main defocus) is relevant but two other orders may also be considered depending on the actual PSF of the system. As an application, we demonstrate that the longitudinal chromatic aberration of the eye can be compensated by the diffractive lens dispersion when the appropriate defocus is programmed into the SLM.
Collapse
|
24
|
Marcos S, Werner JS, Burns SA, Merigan WH, Artal P, Atchison DA, Hampson KM, Legras R, Lundstrom L, Yoon G, Carroll J, Choi SS, Doble N, Dubis AM, Dubra A, Elsner A, Jonnal R, Miller DT, Paques M, Smithson HE, Young LK, Zhang Y, Campbell M, Hunter J, Metha A, Palczewska G, Schallek J, Sincich LC. Vision science and adaptive optics, the state of the field. Vision Res 2017; 132:3-33. [PMID: 28212982 PMCID: PMC5437977 DOI: 10.1016/j.visres.2017.01.006] [Citation(s) in RCA: 82] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2016] [Revised: 01/24/2017] [Accepted: 01/25/2017] [Indexed: 12/27/2022]
Abstract
Adaptive optics is a relatively new field, yet it is spreading rapidly and allows new questions to be asked about how the visual system is organized. The editors of this feature issue have posed a series of question to scientists involved in using adaptive optics in vision science. The questions are focused on three main areas. In the first we investigate the use of adaptive optics for psychophysical measurements of visual system function and for improving the optics of the eye. In the second, we look at the applications and impact of adaptive optics on retinal imaging and its promise for basic and applied research. In the third, we explore how adaptive optics is being used to improve our understanding of the neurophysiology of the visual system.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | - Yuhua Zhang
- University of Alabama at Birmingham, Birmingham, USA
| | | | | | | | | | | | | |
Collapse
|
25
|
Manzanera S, Artal P. Minimum change in spherical aberration that can be perceived. BIOMEDICAL OPTICS EXPRESS 2016; 7:3471-3477. [PMID: 27699113 PMCID: PMC5030025 DOI: 10.1364/boe.7.003471] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2016] [Revised: 08/09/2016] [Accepted: 08/11/2016] [Indexed: 05/16/2023]
Abstract
It is important to know the visual sensitivity to optical blur from both a basic science perspective and a practical point of view. Of particular interest is the sensitivity to blur induced by spherical aberration because it is being used to increase depth of focus as a component of a presbyopic solution. Using a flicker detection-based procedure implemented on an adaptive optics visual simulator, we measured the spherical aberration thresholds that produce just-noticeable differences in perceived image quality. The thresholds were measured for positive and negative values of spherical aberration, for best focus and + 0.5 D and + 1.0 D of defocus. At best focus, the SA thresholds were 0.20 ± 0.01 µm and -0.17 ± 0.03 µm for positive and negative spherical aberration respectively (referred to a 6-mm pupil). These experimental values may be useful in setting spherical aberration permissible levels in different ophthalmic techniques.
Collapse
|
26
|
Fuentes JLM, Fernández EJ, Prieto PM, Artal P. Interferometric method for phase calibration in liquid crystal spatial light modulators using a self-generated diffraction-grating. OPTICS EXPRESS 2016; 24:14159-14171. [PMID: 27410574 DOI: 10.1364/oe.24.014159] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
An auto-referenced interferometric method for calibrating phase modulation of parallel-aligned liquid crystal (PAL) spatial light modulators (SLM) is described. The method is experimentally straightforward, robust, and requires solely of a collimated beam, with no need of additional optics. This method uses the SLM itself to create a tilted plane wave and a reference wave which mutually interfere. These waves are codified by means of a binary diffraction grating and a uniformly distributed gray level area (piston) into the SLM surface. Phase shift for each gray level addressed to the piston section can then be evaluated. Phase modulation on the SLM can also be retrieved with the proposed method over spatially resolved portions of the surface. Phase information obtained with this novel method is compared to other well established calibration procedures, requiring extra elements and more elaborated optical set-ups. The results show a good agreement with previous methods. The advantages of the new method include high mechanical stability, faster performance, and a significantly easier practical implementation.
Collapse
|
27
|
García-Guerra CE, Aldaba M, Arjona M, Pujol J. Binocular open-view system to perform estimations of aberrations and scattering in the human eye. APPLIED OPTICS 2015; 54:9504-9508. [PMID: 26560778 DOI: 10.1364/ao.54.009504] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
We present a system that integrates a double-pass (DP) instrument and a Hartmann-Shack (HS) wavefront sensor to provide information not only on aberrations, but also on the scattering that occurs in the human eye. A binocular open-view design permits evaluations to be made under normal viewing conditions. Furthermore, the system is able to compensate for both the spherical and astigmatic refractive errors that occur during measurements by using devices with configurable optical power. The DP and HS techniques provide comparable data after estimating wavefront slopes with respect to the intersections of an ideal grid and compensating for residual errors caused by the optical defects of the measuring system. Once comparable data is obtained, it is possible to use this combined manner of assessment to provide information on scattering. Measurements in an artificial eye suggest that the characteristics of the ocular fundus may induce deviations of DP with respect to the HS data. These differences were quantified in terms of the modulation transfer function in young, healthy eyes measured in infrared light to demonstrate the potential use of the system in visual optics studies.
Collapse
|
28
|
Abstract
This review starts with a brief history and description of adaptive optics (AO) technology, followed by a showcase of the latest capabilities of AO systems for imaging the human retina and an extensive review of the literature on where AO is being used clinically. The review concludes with a discussion on future directions and guidance on usage and interpretation of images from AO systems for the eye.
Collapse
|
29
|
Schwarz C, Manzanera S, Prieto PM, Fernández EJ, Artal P. Comparison of binocular through-focus visual acuity with monovision and a small aperture inlay. BIOMEDICAL OPTICS EXPRESS 2014; 5:3355-66. [PMID: 25360355 PMCID: PMC4206307 DOI: 10.1364/boe.5.003355] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/25/2014] [Revised: 08/15/2014] [Accepted: 08/24/2014] [Indexed: 05/22/2023]
Abstract
Corneal small aperture inlays provide extended depth of focus as a solution to presbyopia. As this procedure is becoming more popular, it is interesting to compare its performance with traditional approaches, such as monovision. Here, binocular visual acuity was measured as a function of object vergence in three subjects by using a binocular adaptive optics vision analyzer. Visual acuity was measured at two luminance levels (photopic and mesopic) under several optical conditions: 1) natural vision (4 mm pupils, best corrected distance vision), 2) pure-defocus monovision ( + 1.25 D add in the nondominant eye), 3) small aperture monovision (1.6 mm pupil in the nondominant eye), and 4) combined small aperture and defocus monovision (1.6 mm pupil and a + 0.75 D add in the nondominant eye). Visual simulations of a small aperture corneal inlay suggest that the device extends DOF as effectively as traditional monovision in photopic light, in both cases at the cost of binocular summation. However, individual factors, such as aperture centration or sensitivity to mesopic conditions should be considered to assure adequate visual outcomes.
Collapse
Affiliation(s)
- Christina Schwarz
- Laboratorio de Óptica, Instituto Universitario de Investigación en Óptica y Nanofísica, Universidad de Murcia, Campus de Espinardo (Edificio 34), 30100 Murcia, Spain
| | - Silvestre Manzanera
- Laboratorio de Óptica, Instituto Universitario de Investigación en Óptica y Nanofísica, Universidad de Murcia, Campus de Espinardo (Edificio 34), 30100 Murcia, Spain
| | - Pedro M. Prieto
- Laboratorio de Óptica, Instituto Universitario de Investigación en Óptica y Nanofísica, Universidad de Murcia, Campus de Espinardo (Edificio 34), 30100 Murcia, Spain
| | - Enrique J. Fernández
- Laboratorio de Óptica, Instituto Universitario de Investigación en Óptica y Nanofísica, Universidad de Murcia, Campus de Espinardo (Edificio 34), 30100 Murcia, Spain
| | - Pablo Artal
- Laboratorio de Óptica, Instituto Universitario de Investigación en Óptica y Nanofísica, Universidad de Murcia, Campus de Espinardo (Edificio 34), 30100 Murcia, Spain
| |
Collapse
|
30
|
Chirre E, Prieto PM, Artal P. Binocular open-view instrument to measure aberrations and pupillary dynamics. OPTICS LETTERS 2014; 39:4773-5. [PMID: 25121871 DOI: 10.1364/ol.39.004773] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
We have designed and built a binocular Hartmann-Shack wave-front sensor using a single microlens array and camera for real-time aberration measurement of both eyes in an open-view configuration. Furthermore, the use of a long wavelength (1050 nm) laser diode makes the illumination source completely invisible, so that measurements can be unobtrusively performed while the subject stares at the visual world under realistic conditions. The setup provides a large dynamic range and simultaneous measurements of convergence, pupil size, accommodation, and aberrations. The open-view design not only offers the possibility of measuring the subject's ocular optics under natural conditions but also allows coupling the device with other existing vision testing instruments and setups, which increases its potential to become a powerful tool for different visual optics studies.
Collapse
|
31
|
Fernández EJ, Schwarz C, Prieto PM, Manzanera S, Artal P. Impact on stereo-acuity of two presbyopia correction approaches: monovision and small aperture inlay. BIOMEDICAL OPTICS EXPRESS 2013; 4:822-30. [PMID: 23761846 PMCID: PMC3675862 DOI: 10.1364/boe.4.000822] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2013] [Revised: 03/17/2013] [Accepted: 05/02/2013] [Indexed: 05/06/2023]
Abstract
Some of the different currently applied approaches that correct presbyopia may reduce stereovision. In this work, stereo-acuity was measured for two methods: (1) monovision and (2) small aperture inlay in one eye. When performing the experiment, a prototype of a binocular adaptive optics vision analyzer was employed. The system allowed simultaneous measurement and manipulation of the optics in both eyes of a subject. The apparatus incorporated two programmable spatial light modulators: one phase-only device using liquid crystal on silicon technology for wavefront manipulation and one intensity modulator for controlling the exit pupils. The prototype was also equipped with a stimulus generator for creating retinal disparity based on two micro-displays. The three-needle test was programmed for characterizing stereo-acuity. Subjects underwent a two-alternative forced-choice test. The following cases were tested for the stimulus placed at distance: (a) natural vision; (b) 1.5 D monovision; (c) 0.75 D monovision; (d) natural vision and small pupil; (e) 0.75 D monovision and small pupil. In all cases the standard pupil diameter was 4 mm and the small pupil diameter was 1.6 mm. The use of a small aperture significantly reduced the negative impact of monovision on stereopsis. The results of the experiment suggest that combining micro-monovision with a small aperture, which is currently being implemented as a corneal inlay, can yield values of stereoacuity close to those attained under normal binocular vision.
Collapse
|
32
|
Sabesan R, Zheleznyak L, Yoon G. Binocular visual performance and summation after correcting higher order aberrations. BIOMEDICAL OPTICS EXPRESS 2012; 3:3176-89. [PMID: 23243568 PMCID: PMC3521316 DOI: 10.1364/boe.3.003176] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2012] [Revised: 10/03/2012] [Accepted: 10/04/2012] [Indexed: 05/04/2023]
Abstract
Although the ocular higher order aberrations degrade the retinal image substantially, most studies have investigated their effect on vision only under monocular conditions. Here, we have investigated the impact of binocular higher order aberration correction on visual performance and binocular summation by constructing a binocular adaptive optics (AO) vision simulator. Binocular monochromatic aberration correction using AO improved visual acuity and contrast sensitivity significantly. The improvement however, differed from that achieved under monocular viewing. At high spatial frequency (24 c/deg), the monocular benefit in contrast sensitivity was significantly larger than the benefit achieved binocularly. In addition, binocular summation for higher spatial frequencies was the largest in the presence of subject's native higher order aberrations and was reduced when these aberrations were corrected. This study thus demonstrates the vast potential of binocular AO vision testing in understanding the impact of ocular optics on habitual binocular vision.
Collapse
Affiliation(s)
- Ramkumar Sabesan
- The Institute of Optics, University of Rochester, Rochester, NY 14627, USA ; Center for Visual Science, University of Rochester, Rochester, NY 14627, USA ; Flaum Eye Institute, University of Rochester, NY 14627, USA
| | | | | |
Collapse
|
33
|
Schwarz C, Prieto PM, Fernández EJ, Artal P. Binocular adaptive optics vision analyzer with full control over the complex pupil functions. OPTICS LETTERS 2011; 36:4779-81. [PMID: 22179881 DOI: 10.1364/ol.36.004779] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
We present a binocular adaptive optics vision analyzer fully capable of controlling both amplitude and phase of the two complex pupil functions in each eye of the subject. A special feature of the instrument is its comparatively simple setup. A single reflective liquid crystal on silicon spatial light modulator working in pure phase modulation generates the phase profiles for both pupils simultaneously. In addition, another liquid crystal spatial light modulator working in transmission operates in pure intensity modulation to produce a large variety of pupil masks for each eye. Subjects perform visual tasks through any predefined variations of the complex pupil function for both eyes. As an example of the system efficiency, we recorded images of the stimuli through the system as they were projected at the subject's retina. This instrument proves to be extremely versatile for designing and testing novel ophthalmic elements and simulating visual outcomes, as well as for further research of binocular vision.
Collapse
Affiliation(s)
- Christina Schwarz
- Instituto Universitario de investigación en Óptica y Nanofísica, Universidad de Murcia, Murcia, Spain
| | | | | | | |
Collapse
|
34
|
Martínez-Cuenca R, Durán V, Arines J, Ares J, Jaroszewicz Z, Bará S, Martínez-León L, Lancis J. Closed-loop adaptive optics with a single element for wavefront sensing and correction. OPTICS LETTERS 2011; 36:3702-4. [PMID: 21931438 DOI: 10.1364/ol.36.003702] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
We propose a closed-loop adaptive optical arrangement based on a single spatial light modulator that simultaneously works as a correction unit and as the key element of a wavefront sensor. This is possible by using a liquid crystal on silicon display whose active area is divided into two halves that are respectively programmed for sensing and correction. We analyze the performance of this architecture to implement an adaptive optical system. Results showing a closed-loop operation are reported, as well as a proof of concept for dealing with aberrations comparable to those typically found in human eyes.
Collapse
|
35
|
Abstract
Compared to most ophthalmic technologies, adaptive optics, or AO, is relatively young. The first working systems were presented in 1997 and, owing in part to its complexity, the development of AO systems has been relatively slow. Nevertheless, AO for vision science is coming of age and the scope of applications continues to increase. Applications of AO can be broadly split along two lines; for retinal imaging and for testing visual function. This review will focus on the applications of adaptive optics for testing visual function. Since this represents only a subset of the field of AO for ophthalmoscopy, it is possible to cite virtually every paper that has been published in the field to date. As such, this is a comprehensive review whose intent is to get all readers up to speed on the state of the art. More importantly, perhaps, this review will focus on the types of science that can be accomplished with AO with a view to future applications. The reference list alone is informative, since the reader will quickly discover that the community that is using AO for vision science is rather small. Looking at the dates for the cited papers, the reader will also discover that the field is rapidly expanding.
Collapse
Affiliation(s)
- Austin Roorda
- University of California, Berkeley, Berkeley, CA, USA.
| |
Collapse
|
36
|
Affiliation(s)
- Guoqiang Li
- University of Missouri - St. Louis, College of Optometry, Department of Physics and Astronomy, St. Louis, USA
| |
Collapse
|
37
|
Fernández EJ, Prieto PM, Artal P. Adaptive optics binocular visual simulator to study stereopsis in the presence of aberrations. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2010; 27:A48-55. [PMID: 21045890 DOI: 10.1364/josaa.27.000a48] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
A binocular adaptive optics visual simulator has been devised for the study of stereopsis and of binocular vision in general. The apparatus is capable of manipulating the aberrations of each eye separately while subjects perform visual tests. The correcting device is a liquid-crystal-on-silicon spatial light modulator permitting the control of aberrations in the two eyes of the observer simultaneously in open loop. The apparatus can be operated as an electro-optical binocular phoropter with two micro-displays projecting different scenes to each eye. Stereo-acuity tests (three-needle test and random-dot stereograms) have been programmed for exploring the performance of the instrument. As an example, stereo-acuity has been measured in two subjects in the presence of defocus and/or trefoil, showing a complex relationship between the eye's optical quality and stereopsis. This instrument might serve for a better understanding of the relationship of binocular vision and stereopsis performance and the eye's aberrations.
Collapse
Affiliation(s)
- Enrique J Fernández
- Laboratorio de Óptica, Centro de Investigación en Óptica y Nanofísica (CiOyN), Universidad de Murcia, Campus de Espinardo, E-30071 Murcia, Spain
| | | | | |
Collapse
|
38
|
Li C, Sredar N, Ivers KM, Queener H, Porter J. A correction algorithm to simultaneously control dual deformable mirrors in a woofer-tweeter adaptive optics system. OPTICS EXPRESS 2010; 18:16671-84. [PMID: 20721058 PMCID: PMC2929183 DOI: 10.1364/oe.18.016671] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
We present a direct slope-based correction algorithm to simultaneously control two deformable mirrors (DMs) in a woofer-tweeter adaptive optics system. A global response matrix was derived from the response matrices of each deformable mirror and the voltages for both deformable mirrors were calculated simultaneously. This control algorithm was tested and compared with a 2-step sequential control method in five normal human eyes using an adaptive optics scanning laser ophthalmoscope. The mean residual total root-mean-square (RMS) wavefront errors across subjects after adaptive optics (AO) correction were 0.128 +/- 0.025 microm and 0.107 +/- 0.033 microm for simultaneous and 2-step control, respectively (7.75-mm pupil). The mean intensity of reflectance images acquired after AO convergence was slightly higher for 2-step control. Radially-averaged power spectra calculated from registered reflectance images were nearly identical for all subjects using simultaneous or 2-step control. The correction performance of our new simultaneous dual DM control algorithm is comparable to 2-step control, but is more efficient. This method can be applied to any woofer-tweeter AO system.
Collapse
Affiliation(s)
- Chaohong Li
- College of Optometry, University of Houston, 505 J. Davis Armistead Bldg., Houston, TX 77204-2020,
USA
| | - Nripun Sredar
- College of Optometry, University of Houston, 505 J. Davis Armistead Bldg., Houston, TX 77204-2020,
USA
| | - Kevin M. Ivers
- College of Optometry, University of Houston, 505 J. Davis Armistead Bldg., Houston, TX 77204-2020,
USA
| | - Hope Queener
- College of Optometry, University of Houston, 505 J. Davis Armistead Bldg., Houston, TX 77204-2020,
USA
| | - Jason Porter
- College of Optometry, University of Houston, 505 J. Davis Armistead Bldg., Houston, TX 77204-2020,
USA
| |
Collapse
|
39
|
Artal P, Tabernero J. Optics of human eye: 400 years of exploration from Galileo's time. APPLIED OPTICS 2010; 49:D123-D130. [PMID: 20517354 DOI: 10.1364/ao.49.00d123] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
We present a brief historical background and a description of the main features of the eye's optical properties: the eye is a simple, but rather optimized, optical instrument. It is only since Galileo's time that the importance of the eye as a part of different optical instruments has driven a continuous scientific exploration of ocular optics. In the past decade, the use of wavefront sensing technology allowed us to complete our understating of eye optics as a robust aplanatic system.
Collapse
Affiliation(s)
- Pablo Artal
- Laboratorio de Optica, Centro de Investigación en Optica y Nanofísica, Universidad de Murcia, Campus de Espinardo, 30071 Murcia, Spain.
| | | |
Collapse
|
40
|
Cánovas C, Prieto PM, Manzanera S, Mira A, Artal P. Hybrid adaptive-optics visual simulator. OPTICS LETTERS 2010; 35:196-8. [PMID: 20081966 DOI: 10.1364/ol.35.000196] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
We have developed a hybrid adaptive-optics visual simulator (HAOVS), combining two different phase-manipulation technologies: an optically addressed liquid-crystal phase modulator, relatively slow but capable of producing abrupt or discontinuous phase profiles; and a membrane deformable mirror, restricted to smooth profiles but with a temporal response allowing compensation of the eye's aberration fluctuations. As proof of concept, a phase element structured as discontinuous radial sectors was objectively tested as a function of defocus, and a correction loop was closed in a real eye. To further illustrate the capabilities of the device for visual simulation, we recorded extended images of different stimuli through the system by means of an external camera replacing the subject's eye. The HAOVS is specially intended as a tool for developing new ophthalmic optics elements, where it opens the possibility to explore designs with irregularities and/or discontinuities.
Collapse
Affiliation(s)
- Carmen Cánovas
- Laboratorio de Optica, Centro de Investigación en Optica y Nanofísica (CiOyN), Universidad de Murcia,Campus de Espinardo, E-30071 Murcia, Spain
| | | | | | | | | |
Collapse
|