1
|
Jia H, Chen X, Shen J, Liu R, Hou P, Yue S. Label-Free Fiber-Optic Raman Spectroscopy for Intravascular Coronary Atherosclerosis and Plaque Detection. ACS OMEGA 2024; 9:27789-27797. [PMID: 38973848 PMCID: PMC11223210 DOI: 10.1021/acsomega.4c01611] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Revised: 05/15/2024] [Accepted: 06/12/2024] [Indexed: 07/09/2024]
Abstract
The rupture of atherosclerotic plaques remains one of the leading causes of morbidity and mortality worldwide. The plaques have certain pathological characteristics including a fibrous cap, inflammation, and extensive lipid deposition in a lipid core. Various invasive and noninvasive imaging techniques can interrogate structural aspects of atheroma; however, the composition of the lipid core in coronary atherosclerosis and plaques cannot be accurately detected. Fiber-optic Raman spectroscopy has the capability of in vivo rapid and accurate biomarker detection as an emerging omics technology. Previous studies demonstrated that an intravascular Raman spectroscopic technique may assess and manage the therapeutic and medication strategies intraoperatively. The Raman spectral information identified plaque depositions consisting of lipids, triglycerides, and cholesterol esters as the major components by comparing normal region and early plaque formation region with histology. By focusing on the composition of plaques, we could identify the subgroups of plaques accurately and rapidly by Raman spectroscopy. Collectively, this fiber-optic Raman spectroscopy opens up new opportunities for coronary atherosclerosis and plaque detection, which would assist optimal surgical strategy and instant postoperative decision-making. In this paper, we will review the advancement of label-free fiber-optic Raman probe spectroscopy and its applications of coronary atherosclerosis and atherosclerotic plaque detection.
Collapse
Affiliation(s)
- Hao Jia
- Key
Laboratory of Biomechanics and Mechanobiology (Beihang University),
Ministry of Education, Institute of Medical Photonics, Beijing Advanced
Innovation Center for Biomedical Engineering, School of Biological
Science and Medical Engineering, Beihang
University, Beijing 100191, China
| | - Xun Chen
- Key
Laboratory of Biomechanics and Mechanobiology (Beihang University),
Ministry of Education, Institute of Medical Photonics, Beijing Advanced
Innovation Center for Biomedical Engineering, School of Biological
Science and Medical Engineering, Beihang
University, Beijing 100191, China
| | - Jianghao Shen
- Key
Laboratory of Biomechanics and Mechanobiology (Beihang University),
Ministry of Education, Institute of Medical Photonics, Beijing Advanced
Innovation Center for Biomedical Engineering, School of Biological
Science and Medical Engineering, Beihang
University, Beijing 100191, China
| | - Rujia Liu
- Key
Laboratory of Biomechanics and Mechanobiology (Beihang University),
Ministry of Education, Institute of Medical Photonics, Beijing Advanced
Innovation Center for Biomedical Engineering, School of Biological
Science and Medical Engineering, Beihang
University, Beijing 100191, China
| | - Peipei Hou
- Department
of Cardiology, The People’s Hospital
of China Medical University, Shenyang 110016, China
| | - Shuhua Yue
- Key
Laboratory of Biomechanics and Mechanobiology (Beihang University),
Ministry of Education, Institute of Medical Photonics, Beijing Advanced
Innovation Center for Biomedical Engineering, School of Biological
Science and Medical Engineering, Beihang
University, Beijing 100191, China
| |
Collapse
|
2
|
Galli R, Uckermann O. Vibrational spectroscopy and multiphoton microscopy for label-free visualization of nervous system degeneration and regeneration. Biophys Rev 2024; 16:219-235. [PMID: 38737209 PMCID: PMC11078905 DOI: 10.1007/s12551-023-01158-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Accepted: 09/22/2023] [Indexed: 05/14/2024] Open
Abstract
Neurological disorders, including spinal cord injury, peripheral nerve injury, traumatic brain injury, and neurodegenerative diseases, pose significant challenges in terms of diagnosis, treatment, and understanding the underlying pathophysiological processes. Label-free multiphoton microscopy techniques, such as coherent Raman scattering, two-photon excited autofluorescence, and second and third harmonic generation microscopy, have emerged as powerful tools for visualizing nervous tissue with high resolution and without the need for exogenous labels. Coherent Raman scattering processes as well as third harmonic generation enable label-free visualization of myelin sheaths, while their combination with two-photon excited autofluorescence and second harmonic generation allows for a more comprehensive tissue visualization. They have shown promise in assessing the efficacy of therapeutic interventions and may have future applications in clinical diagnostics. In addition to multiphoton microscopy, vibrational spectroscopy methods such as infrared and Raman spectroscopy offer insights into the molecular signatures of injured nervous tissues and hold potential as diagnostic markers. This review summarizes the application of these label-free optical techniques in preclinical models and illustrates their potential in the diagnosis and treatment of neurological disorders with a special focus on injury, degeneration, and regeneration. Furthermore, it addresses current advancements and challenges for bridging the gap between research findings and their practical applications in a clinical setting.
Collapse
Affiliation(s)
- Roberta Galli
- Medical Physics and Biomedical Engineering, Faculty of Medicine, Technische Universität Dresden, Dresden, Germany
| | - Ortrud Uckermann
- Department of Neurosurgery, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
- Division of Medical Biology, Department of Psychiatry and Psychotherapy, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| |
Collapse
|
3
|
Banbury C, Harris G, Clancy M, Blanch RJ, Rickard JJS, Goldberg Oppenheimer P. Window into the mind: Advanced handheld spectroscopic eye-safe technology for point-of-care neurodiagnostic. SCIENCE ADVANCES 2023; 9:eadg5431. [PMID: 37967190 PMCID: PMC10651125 DOI: 10.1126/sciadv.adg5431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Accepted: 10/19/2023] [Indexed: 11/17/2023]
Abstract
Traumatic brain injury (TBI), a major cause of morbidity and mortality worldwide, is hard to diagnose at the point of care with patients often exhibiting no clinical symptoms. There is an urgent need for rapid point-of-care diagnostics to enable timely intervention. We have developed a technology for rapid acquisition of molecular fingerprints of TBI biochemistry to safely measure proxies for cerebral injury through the eye, providing a path toward noninvasive point-of-care neurodiagnostics using simultaneous Raman spectroscopy and fundus imaging of the neuroretina. Detection of endogenous neuromarkers in porcine eyes' posterior revealed enhancement of high-wave number bands, clearly distinguishing TBI and healthy cohorts, classified via artificial neural network algorithm for automated data interpretation. Clinically, translating into reduced specialist support, this markedly improves the speed of diagnosis. Designed as a hand-held cost-effective technology, it can allow clinicians to rapidly assess TBI at the point of care and identify long-term changes in brain biochemistry in acute or chronic neurodiseases.
Collapse
Affiliation(s)
- Carl Banbury
- School of Chemical Engineering, Advanced Nanomaterials Structures and Applications Laboratories, College of Engineering and Physical Sciences, University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK
| | - Georgia Harris
- School of Chemical Engineering, Advanced Nanomaterials Structures and Applications Laboratories, College of Engineering and Physical Sciences, University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK
| | - Michael Clancy
- School of Chemical Engineering, Advanced Nanomaterials Structures and Applications Laboratories, College of Engineering and Physical Sciences, University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK
- Ministry of Justice, 102 Petty France, Westminster, London, UK
| | - Richard J. Blanch
- Department of Military Surgery and Trauma, Royal Centre for Defence Medicine, Birmingham, UK
- Neuroscience and Ophthalmology, Institute of Inflammation and Ageing, College of Medical and Dental Sciences, Robert Aiken Institute for Clinical Research, University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK
- Department of Ophthalmology, Queen Elizabeth Hospital Birmingham, UHB NHS Foundation Trust, West Midlands, UK
| | | | - Pola Goldberg Oppenheimer
- School of Chemical Engineering, Advanced Nanomaterials Structures and Applications Laboratories, College of Engineering and Physical Sciences, University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK
- Healthcare Technologies Institute, Institute of Translational Medicine, Mindelsohn Way, Birmingham, B15 2TH, UK
| |
Collapse
|
4
|
Wang J, Chen S, Zhang R, Lin K, Wang T, Liu W, Zhang A. Development of a two-beveled-fiber polarized fiber-optic Raman probe coupled with a ball lens for in vivo superficial epithelial Raman measurements in endoscopy. OPTICS LETTERS 2023; 48:4885-4888. [PMID: 37707928 DOI: 10.1364/ol.495912] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Accepted: 08/01/2023] [Indexed: 09/15/2023]
Abstract
We report on the development of a two-beveled-fiber polarized (TBFP) fiber-optic Raman probe coupled with a ball lens for in vivo superficial epithelial Raman measurements in endoscopy. The two-beveled fibers positioned symmetrically along a ball lens, in synergy with paired parallel-polarized polarizers integrated between the fibers and the ball lens, maximize the Raman signal excitation and collection from the superficial epithelium where gastrointestinal (GI) precancer arises. Monte Carlo (MC) simulations and two-layer tissue phantom experiments show that the probe developed detects ∼90% of the Raman signal from the superficial epithelium. The suitability of the probe developed for rapid (<3 s) superficial epithelial Raman measurements is demonstrated on fresh swine esophagus, stomach, and colon tissues, followed by their differentiation with high accuracies (92.1% for esophagus [sensitivity: 89.3%, specificity: 93.2%], 94.1% for stomach [sensitivity: 86.2%, specificity: 97.2%], and 94.1% for colon [sensitivity: 93.2%, specificity: 94.7%]). The presented results suggest the great potential of the developed probe for enhancing in vivo superficial epithelial Raman measurements in endoscopy.
Collapse
|
5
|
Qiu B, Shu C, Huang Z. Development of a multi-needle fiberoptic Raman spectroscopy technique for simultaneous multi-site deep tissue Raman measurements in the brain. OPTICS LETTERS 2023; 48:4396-4399. [PMID: 37582041 DOI: 10.1364/ol.498232] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Accepted: 07/23/2023] [Indexed: 08/17/2023]
Abstract
We report on the development of a multi-needle fiberoptic Raman spectroscopy (MNF-RS) technique for simultaneous multi-site deep Raman measurements in brain tissue. The multi-needle fiberoptic Raman probe is designed and fabricated using a number of 100 µm core diameter, aluminum-coated fibers under a coaxial laser excitation and Raman collection scheme, enabling simultaneous collection of deep tissue Raman spectra from a number of tissue sites. We have also developed a Raman retrieval algorithm based on the transformation matrix of each individual needle fiber probe projected to different pixels of a charge-coupled device (CCD) for recovering the tissue Raman spectra collected by each needle fiber probe, allowing simultaneous multi-channel detection by a single Raman spectrometer. High-quality tissue Raman spectra of different tissue types (e.g., muscle, fat, gray matter, and white matter in porcine brain) can be acquired in both the fingerprint (900-1800 cm-1) and high-wavenumber (2800-3300 cm-1) regions within sub-second times using the MNF-RS technique. We also demonstrate that by advancing the multi-needle fiberoptic Raman probe into deep porcine brain, tissue Raman spectra can be acquired simultaneously from different brain regions (e.g., cortex, thalamus, midbrain, and cerebellum). The significant biochemical differences across different brain tissues can also be distinguished, suggesting the promising potential of the MNF-RS technique for label-free neuroscience study at the molecular level.
Collapse
|
6
|
Heng HPS, Shu C, Zheng W, Huang Z. Development of a coaxial DCF-GRIN fiberoptic Raman probe for enhancing in vivo epithelial tissue Raman measurements. OPTICS LETTERS 2022; 47:5989-5992. [PMID: 37219154 DOI: 10.1364/ol.474464] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Accepted: 10/20/2022] [Indexed: 05/24/2023]
Abstract
We report on the development of a novel, to the best of our knowledge, coaxial double-clad-fiber (DCF) and graded-index (GRIN) fiberoptic Raman probe for enhancing epithelial tissue Raman measurements in vivo. The ultra-thin (140 µm outer diameter) DCF-GRIN fiberoptic Raman probe is designed and fabricated with an efficient coaxial optical configuration, whereby a GRIN fiber is spliced onto the DCF to enhance both the excitation/collection efficiency and depth-resolved selectivity. We demonstrate that the DCF-GRIN Raman probe can be used to acquire high-quality in vivo Raman spectra from various oral tissues (e.g., buccal mucosa, labial mucosa, gingiva, mouth floor, palate, and tongue) covering both the fingerprint (800-1800 cm-1) and high-wavenumber (2800-3600 cm-1) regions within sub-seconds. The subtle biochemical differences between different epithelial tissues in the oral cavity can also be detected with high sensitivity, suggesting the potential of the DCF-GRIN fiberoptic Raman probe for in vivo diagnosis and characterization in epithelial tissue.
Collapse
|
7
|
Zhou C, Lin Z, Huang S, Li B, Gao A. Progress in Probe-Based Sensing Techniques for In Vivo Diagnosis. BIOSENSORS 2022; 12:943. [PMID: 36354452 PMCID: PMC9688418 DOI: 10.3390/bios12110943] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Revised: 10/13/2022] [Accepted: 10/24/2022] [Indexed: 06/16/2023]
Abstract
Advancements in robotic surgery help to improve the endoluminal diagnosis and treatment with minimally invasive or non-invasive intervention in a precise and safe manner. Miniaturized probe-based sensors can be used to obtain information about endoluminal anatomy, and they can be integrated with medical robots to augment the convenience of robotic operations. The tremendous benefit of having this physiological information during the intervention has led to the development of a variety of in vivo sensing technologies over the past decades. In this paper, we review the probe-based sensing techniques for the in vivo physical and biochemical sensing in China in recent years, especially on in vivo force sensing, temperature sensing, optical coherence tomography/photoacoustic/ultrasound imaging, chemical sensing, and biomarker sensing.
Collapse
Affiliation(s)
- Cheng Zhou
- Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai 200240, China
- Department of Automation, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Zecai Lin
- Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai 200240, China
- Department of Automation, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Shaoping Huang
- Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai 200240, China
- Department of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Bing Li
- Institute for Materials Discovery, University College London, London WC1E 7JE, UK
| | - Anzhu Gao
- Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai 200240, China
- Department of Automation, Shanghai Jiao Tong University, Shanghai 200240, China
| |
Collapse
|