1
|
Bjegovic K, Sun L, Pandey P, Grilj V, Ballesteros-Zebadua P, Paisley R, Gonzalez G, Wang S, Vozenin MC, Limoli CL, Xiang SL. 4D in vivodosimetry for a FLASH electron beam using radiation-induced acoustic imaging. Phys Med Biol 2024; 69:115053. [PMID: 38722574 DOI: 10.1088/1361-6560/ad4950] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2024] [Accepted: 05/09/2024] [Indexed: 06/01/2024]
Abstract
Objective. The primary goal of this research is to demonstrate the feasibility of radiation-induced acoustic imaging (RAI) as a volumetric dosimetry tool for ultra-high dose rate FLASH electron radiotherapy (FLASH-RT) in real time. This technology aims to improve patient outcomes by accurate measurements ofin vivodose delivery to target tumor volumes.Approach. The study utilized the FLASH-capable eRT6 LINAC to deliver electron beams under various doses (1.2 Gy pulse-1to 4.95 Gy pulse-1) and instantaneous dose rates (1.55 × 105Gy s-1to 2.75 × 106Gy s-1), for imaging the beam in water and in a rabbit cadaver with RAI. A custom 256-element matrix ultrasound array was employed for real-time, volumetric (4D) imaging of individual pulses. This allowed for the exploration of dose linearity by varying the dose per pulse and analyzing the results through signal processing and image reconstruction in RAI.Main Results. By varying the dose per pulse through changes in source-to-surface distance, a direct correlation was established between the peak-to-peak amplitudes of pressure waves captured by the RAI system and the radiochromic film dose measurements. This correlation demonstrated dose rate linearity, including in the FLASH regime, without any saturation even at an instantaneous dose rate up to 2.75 × 106Gy s-1. Further, the use of the 2D matrix array enabled 4D tracking of FLASH electron beam dose distributions on animal tissue for the first time.Significance. This research successfully shows that 4Din vivodosimetry is feasible during FLASH-RT using a RAI system. It allows for precise spatial (∼mm) and temporal (25 frames s-1) monitoring of individual FLASH beamlets during delivery. This advancement is crucial for the clinical translation of FLASH-RT as enhancing the accuracy of dose delivery to the target volume the safety and efficacy of radiotherapeutic procedures will be improved.
Collapse
Affiliation(s)
- Kristina Bjegovic
- The Department of Biomedical Engineering, University of California, Irvine, CA 92617, United States of America
| | - Leshan Sun
- The Department of Biomedical Engineering, University of California, Irvine, CA 92617, United States of America
| | - Prabodh Pandey
- Department of Radiological Sciences, University of California, Irvine, Irvine, CA 92697, United States of Americaica
| | - Veljko Grilj
- Laboratory of Radiation Oncology, Radiation Oncology Service and Oncology Department, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Paola Ballesteros-Zebadua
- Laboratory of Radiation Oncology, Radiation Oncology Service and Oncology Department, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- Laboratory of Medical Physics, National Institute of Neurology and Neurosurgery, Mexico City, Mexico
| | - Ryan Paisley
- Laboratory of Radiation Oncology, Radiation Oncology Service and Oncology Department, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Gilberto Gonzalez
- Department of Radiation Oncology, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, United States of America
| | - Siqi Wang
- The Department of Biomedical Engineering, University of California, Irvine, CA 92617, United States of America
| | - Marie Catherine Vozenin
- Laboratory of Radiation Oncology, Radiation Oncology Service and Oncology Department, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- Sector of Radiobiology applied to Radiation Oncology, Radiation Oncology Service, Geneva University Hospital and University of Geneva, Geneva, Switzerland
| | - Charles L Limoli
- Department of Radiation Oncology, University of California, Irvine, Irvine, CA 92697-2695, United States of America
| | - Shawn Liangzhong Xiang
- The Department of Biomedical Engineering, University of California, Irvine, CA 92617, United States of America
- Department of Radiological Sciences, University of California, Irvine, Irvine, CA 92697, United States of Americaica
- Beckman Laser Institute & Medical Clinic, University of California, Irvine, Irvine, CA 92612, United States of America
| |
Collapse
|
2
|
Cho SW, Nguyen VT, DiSpirito A, Yang J, Kim CS, Yao J. Sounding out the dynamics: a concise review of high-speed photoacoustic microscopy. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:S11521. [PMID: 38323297 PMCID: PMC10846286 DOI: 10.1117/1.jbo.29.s1.s11521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Revised: 12/15/2023] [Accepted: 01/11/2024] [Indexed: 02/08/2024]
Abstract
Significance Photoacoustic microscopy (PAM) offers advantages in high-resolution and high-contrast imaging of biomedical chromophores. The speed of imaging is critical for leveraging these benefits in both preclinical and clinical settings. Ongoing technological innovations have substantially boosted PAM's imaging speed, enabling real-time monitoring of dynamic biological processes. Aim This concise review synthesizes historical context and current advancements in high-speed PAM, with an emphasis on developments enabled by ultrafast lasers, scanning mechanisms, and advanced imaging processing methods. Approach We examine cutting-edge innovations across multiple facets of PAM, including light sources, scanning and detection systems, and computational techniques and explore their representative applications in biomedical research. Results This work delineates the challenges that persist in achieving optimal high-speed PAM performance and forecasts its prospective impact on biomedical imaging. Conclusions Recognizing the current limitations, breaking through the drawbacks, and adopting the optimal combination of each technology will lead to the realization of ultimate high-speed PAM for both fundamental research and clinical translation.
Collapse
Affiliation(s)
- Soon-Woo Cho
- Duke University, Department of Biomedical Engineering, Durham, North Carolina, United States
- Pusan National University, Engineering Research Center for Color-Modulated Extra-Sensory Perception Technology, Busan, Republic of Korea
| | - Van Tu Nguyen
- Duke University, Department of Biomedical Engineering, Durham, North Carolina, United States
| | - Anthony DiSpirito
- Duke University, Department of Biomedical Engineering, Durham, North Carolina, United States
| | - Joseph Yang
- Duke University, Department of Biomedical Engineering, Durham, North Carolina, United States
| | - Chang-Seok Kim
- Pusan National University, Engineering Research Center for Color-Modulated Extra-Sensory Perception Technology, Busan, Republic of Korea
| | - Junjie Yao
- Duke University, Department of Biomedical Engineering, Durham, North Carolina, United States
| |
Collapse
|
3
|
Sun T, Zhang Z, Cui D, Mu G, Sun X, Su X, Shi Y. Quantitative 3D Temperature Rendering of Deep Tumors by a NIR-II Reversibly Responsive W-VO 2@PEG Photoacoustic Nanothermometer to Promote Precise Cancer Photothermal Therapy. ACS NANO 2023; 17:14604-14618. [PMID: 37471572 DOI: 10.1021/acsnano.3c01723] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/22/2023]
Abstract
Accurately monitoring the three-dimensional (3D) temperature distribution of the tumor area in situ is a critical task that remains challenging in precision cancer photothermal (PT) therapy. Here, by ingeniously constructing a polyethylene glycol-coated tungsten-doped vanadium dioxide (W-VO2@PEG) photoacoustic (PA) nanothermometer (NThem) that linearly and reversibly responds to the thermal field near the human-body-temperature range, the authors propose a method to realize quantitative 3D temperature rendering of deep tumors to promote precise cancer PT therapy. The prepared NThems exhibit a mild phase transition from the monoclinic phase to the rutile phase when their temperature grows from 35 to 45 °C, with the optical absorption sharply increased ∼2-fold at 1064 nm in an approximately linear manner in the near-infrared-II (NIR-II) region, enabling W-VO2@PEG to be used as NThems for quantitative temperature monitoring of deep tumors with basepoint calibration, as well as diagnostic agents for PT therapy. Experimental results showed that the temperature measurement accuracy of the proposed method can reach 0.3 °C, with imaging depths up to 2 and 0.65 cm in tissue-mimicking phantoms and mouse tumor tissue, respectively. In addition, it was verified through PT therapy experiments in mice that the proposed method can achieve extremely high PT therapy efficiency by monitoring the temperature of the target area during PT therapy. This work provides a potential demonstration promoting precise cancer PT therapy through quantitative 3D temperature rendering of deep tumors by PA NThems with higher security and higher efficacy.
Collapse
Affiliation(s)
- Ting Sun
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| | - Zhenhui Zhang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| | - Dandan Cui
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| | - Gen Mu
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| | - Xiaodong Sun
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| | - Xiaoye Su
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| | - Yujiao Shi
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| |
Collapse
|
4
|
Mu G, Zhang Z, Cui D, Chen W, Shi Y. Universal visualization of crystalline orientation for black phosphorus by angle-resolved polarized photoacoustic microscopy. OPTICS LETTERS 2023; 48:2748-2751. [PMID: 37186756 DOI: 10.1364/ol.489709] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Anisotropic two-dimensional (2D) materials, such as black phosphorus (BP), normally possess unique directional in-plane electrical, optical, and thermal properties that are highly correlated with their crystalline orientations. Nondestructive visualization of their crystalline orientation is an indispensable premise for the 2D materials to harness their distinctive strengths in optoelectronic and thermoelectric applications. Here, by photoacoustically recording the anisotropic optical absorption variation under linearly polarized laser beams, an angle-resolved polarized photoacoustic microscopy (AnR-PPAM) is developed, capable of non-invasively determining and visualizing BP's crystalline orientation. We theoretically deduced the physical relationship between the crystalline orientation and polarized photoacoustic (PA) signals, and experimentally proved the ability of AnR-PPAM to universally visualize BP's crystalline orientation regardless of its thickness, substrate, and encapsulation layer. This method provides a new, to the best of our knowledge, strategy for crystalline orientation recognition of 2D materials with flexible measurement conditions, prefiguring important potential for the applications of anisotropic 2D materials.
Collapse
|
5
|
Khorin PA, Porfirev AP, Khonina SN. Composite Diffraction-Free Beam Formation Based on Iteratively Calculated Primitives. MICROMACHINES 2023; 14:mi14050989. [PMID: 37241614 DOI: 10.3390/mi14050989] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Revised: 04/27/2023] [Accepted: 04/28/2023] [Indexed: 05/28/2023]
Abstract
To form a diffraction-free beam with a complex structure, we propose to use a set of primitives calculated iteratively for the ring spatial spectrum. We also optimized the complex transmission function of the diffractive optical elements (DOEs), which form some primitive diffraction-free distributions (for example, a square or/and a triangle). The superposition of such DOEs supplemented with deflecting phases (a multi-order optical element) provides to generate a diffraction-free beam with a more complex transverse intensity distribution corresponding to the composition of these primitives. The proposed approach has two advantages. The first is the rapid (for the first few iterations) achievements of an acceptable error in the calculation of an optical element that forms a primitive distribution compared to a complex one. The second advantage is the convenience of reconfiguration. Since a complex distribution is assembled from primitive parts, it can be reconfigured quickly or dynamically by using a spatial light modulator (SLM) by moving and rotating these components. Numerical results were confirmed experimentally.
Collapse
Affiliation(s)
- Pavel A Khorin
- Samara National Research University, Samara 443086, Russia
- Image Processing Systems Institute of RAS-Branch of the FSRC "Crystallography and Photonics" RAS, Samara 443001, Russia
| | - Alexey P Porfirev
- Samara National Research University, Samara 443086, Russia
- Image Processing Systems Institute of RAS-Branch of the FSRC "Crystallography and Photonics" RAS, Samara 443001, Russia
| | - Svetlana N Khonina
- Samara National Research University, Samara 443086, Russia
- Image Processing Systems Institute of RAS-Branch of the FSRC "Crystallography and Photonics" RAS, Samara 443001, Russia
| |
Collapse
|
6
|
Cao R, Zhao J, Li L, Du L, Zhang Y, Luo Y, Jiang L, Davis S, Zhou Q, de la Zerda A, Wang LV. Optical-resolution photoacoustic microscopy with a needle-shaped beam. NATURE PHOTONICS 2023; 17:89-95. [PMID: 38149029 PMCID: PMC10751030 DOI: 10.1038/s41566-022-01112-w] [Citation(s) in RCA: 21] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Accepted: 10/19/2022] [Indexed: 12/28/2023]
Abstract
Optical-resolution photoacoustic microscopy (OR-PAM) can visualize wavelength-dependent optical absorption at the cellular level. However, OR-PAM suffers from a limited depth of field (DOF) due to the tight focus of the optical excitation beam, making it challenging to acquire high-resolution images of samples with uneven surfaces or high-quality volumetric images without z-scanning. To overcome this limitation, we propose needle-shaped beam photoacoustic microscopy (NB-PAM), which can extend the DOF to up to ~28-fold Rayleigh lengths via customized diffractive optical elements (DOEs). The DOE generate a needle beam with a well-maintained beam diameter, a uniform axial intensity distribution, and negligible sidelobes. The advantage of using NB-PAM is demonstrated by both histology-like imaging of fresh slide-free organs using a 266 nm laser and in vivo mouse brain vasculature imaging using a 532 nm laser. The approach provides new perspectives for slide-free intraoperative pathological imaging and in-vivo organ-level imaging.
Collapse
Affiliation(s)
- Rui Cao
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, California, USA
| | - Jingjing Zhao
- Department of Structural Biology, Stanford University School of Medicine, Stanford University, Stanford, California, USA
| | - Lei Li
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, California, USA
| | - Lin Du
- Department of Electrical and Systems Engineering, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Yide Zhang
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, California, USA
| | - Yilin Luo
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, California, USA
| | - Laiming Jiang
- Department of Biomedical Engineering and Ophthalmology, Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA
| | - Samuel Davis
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, California, USA
| | - Qifa Zhou
- Department of Biomedical Engineering and Ophthalmology, Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA
| | - Adam de la Zerda
- Department of Structural Biology, Stanford University School of Medicine, Stanford University, Stanford, California, USA
- Biophysics Program, Molecular Imaging Program, and Bio-X Program at Stanford University, Stanford, California, USA
- Chan Zuckerberg Biohub, San Francisco, California, USA
| | - Lihong V Wang
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, California, USA
| |
Collapse
|
7
|
Song X, Chen G, Zhao A, Liu X, Zeng J. Virtual optical-resolution photoacoustic microscopy using the k-Wave method. APPLIED OPTICS 2021; 60:11241-11246. [PMID: 35201116 DOI: 10.1364/ao.444106] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Accepted: 11/27/2021] [Indexed: 06/14/2023]
Abstract
Deep learning has been widely used in image processing, quantitative analysis, and other applications in optical-resolution photoacoustic microscopy (OR-PAM). It requires a large amount of photoacoustic data for training and testing. However, due to the complex structure, high cost, slow imaging speed, and other factors of OR-PAM, it is difficult to obtain enough data required by deep learning, which limits the research of deep learning in OR-PAM to a certain extent. To solve this problem, a virtual OR-PAM based on k-Wave is proposed. The virtual photoacoustic microscopy mainly includes the setting of excitation light source and ultrasonic probe, scanning and signal processing, which can realize the common Gaussian-beam and Bessel-beam OR-PAMs. The system performance (lateral resolution, axial resolution, and depth of field) was tested by imaging a vertically tilted fiber, and the effectiveness and feasibility of the virtual simulation platform were verified by 3D imaging of the virtual vascular network. The ability to the generation of the dataset for deep learning was also verified. The construction of the virtual OR-PAM can promote the research of OR-PAM and the application of deep learning in OR-PAM.
Collapse
|
8
|
Li Y, Ye F, Zhang S, Ni W, Wen L, Qin H. Carbon-Coated Magnetic Nanoparticle Dedicated to MRI/Photoacoustic Imaging of Tumor in Living Mice. Front Bioeng Biotechnol 2021; 9:800744. [PMID: 34926438 PMCID: PMC8675129 DOI: 10.3389/fbioe.2021.800744] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2021] [Accepted: 11/08/2021] [Indexed: 11/17/2022] Open
Abstract
Multimodality imaging can reveal complementary anatomic and functional information as they exploit different contrast mechanisms, which has broad clinical applications and promises to improve the accuracy of tumor diagnosis. Accordingly, to attain the particular goal, it is critical to exploit multimodal contrast agents. In the present work, we develop novel cobalt core/carbon shell-based nanoparticles (Cobalt at carbon NPs) with both magnetization and light absorption properties for dual-modality magnetic resonance imaging (MRI) and photoacoustic imaging (PAI). The nanoparticle consists of ferromagnetic cobalt particles coated with carbon for biocompatibility and optical absorption. In addition, the prepared Cobalt at carbon NPs are characterized by transmission electron microscope (TEM), visible-near-infrared spectra, Raman spectrum, and X-ray powder diffraction for structural analysis. Experiments verify that Cobalt at carbon NPs have been successfully constructed and the designed Cobalt at carbon NPs can be detected by both MRI and PAI in vitro and in vivo. Importantly, intravenous injection of Cobalt at carbon NPs into glioblastoma-bearing mice led to accumulation and retention of Cobalt at carbon NPs in the tumors. Using such a multifunctional probe, MRI can screen rapidly to identify potential lesion locations, whereas PAI can provide high-resolution morphological structure and quantitative information of the tumor. The Cobalt at carbon NPs are likely to become a promising candidate for dual-modality MRI/PAI of the tumor.
Collapse
Affiliation(s)
- Yujing Li
- MOE Key Laboratory of Laser Life Science and Institute of Laser Life Science, Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, College of Biophotonics, South China Normal University, Guangzhou, China
| | - Fei Ye
- Zhuhai Precision Medical Center, Zhuhai People’s Hospital, Zhuhai Hospital Affiliated with Jinan University, Zhuhai, China
| | - Shanxiang Zhang
- MOE Key Laboratory of Laser Life Science and Institute of Laser Life Science, Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, College of Biophotonics, South China Normal University, Guangzhou, China
| | - Wenjun Ni
- Zhuhai Precision Medical Center, Zhuhai People’s Hospital, Zhuhai Hospital Affiliated with Jinan University, Zhuhai, China
| | - Liewei Wen
- Zhuhai Precision Medical Center, Zhuhai People’s Hospital, Zhuhai Hospital Affiliated with Jinan University, Zhuhai, China
| | - Huan Qin
- MOE Key Laboratory of Laser Life Science and Institute of Laser Life Science, Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, College of Biophotonics, South China Normal University, Guangzhou, China
- Guangzhou Key Lab of Spectral Analysis and Functional Probes, College of Biophotonics, South China Normal University, Guangzhou, China
| |
Collapse
|
9
|
Cui D, Shi Y, Xing D, Yang S. Ultrahigh Sensitive and Tumor-Specific Photoacoustography in NIR-II Region: Optical Writing and Redox-Responsive Graphic Fixing by AgBr@PLGA Nanocrystals. NANO LETTERS 2021; 21:6914-6922. [PMID: 34428906 DOI: 10.1021/acs.nanolett.1c02078] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
The highly up-regulated glutathione (GSH) concentration in the tumor microenvironment is generally identified to be an effective endogenous characteristic of cancerous tissues. Herein, an ultrahigh-sensitive and tumor-specific photoacoustography technique in the near-infrared (NIR-II) region based on optical writing and redox-responsive chromogenic graphic fixing is developed by introducing a self-synthesized photosensitive silver bromide modified with poly lactic-co-glycolic acid (AgBr@PLGA) nanocrystals. After they are optically triggered by external light, the NIR-transparent AgBr@PLGA nanocrystals can be reduced by the tumor-abundant GSH into strongly absorbing silver nanoparticles, significantly boosting the "turn-on" photoacoustic (PA) signal in the NIR-II region; therefore, the tumor area can be graphically fixed and developed in the photoacoustography. Experiments on both in vitro phantoms and in vivo mouse models demonstrate that the tumor area is specifically identified by the photoacoustography with the background signals effectively suppressed by dynamically modulating the exposure time. The tumor-specific photoacoustography technique prefigures great potential for high-precision cancer diagnosis and treatment monitoring.
Collapse
Affiliation(s)
- Dandan Cui
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| | - Yujiao Shi
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| | - Da Xing
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| | - Sihua Yang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| |
Collapse
|
10
|
Zeroth- and first-order long range non-diffracting Gauss-Bessel beams generated by annihilating multiple-charged optical vortices. Sci Rep 2020; 10:21981. [PMID: 33319796 PMCID: PMC7738530 DOI: 10.1038/s41598-020-78613-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Accepted: 11/18/2020] [Indexed: 11/15/2022] Open
Abstract
We demonstrate an alternative approach for generating zeroth- and first-order long range non-diffracting Gauss–Bessel beams (GBBs). Starting from a Gaussian beam, the key point is the creation of a bright ring-shaped beam with a large radius-to-width ratio, which is subsequently Fourier-transformed by a thin lens. The phase profile required for creating zeroth-order GBBs is flat and helical for first-order GBBs with unit topological charge (TC). Both the ring-shaped beam and the required phase profile can be realized by creating highly charged optical vortices by a spatial light modulator and annihilating them by using a second modulator of the same type. The generated long-range GBBs are proven to have negligible transverse evolution up to 2 m and can be regarded as non-diffracting. The influences of the charge state of the TCs, the propagation distance behind the focusing lens, and the GBB profiles on the relative intensities of the peak/rings are discussed. The method is much more efficient as compared to this using annular slits in the back focal plane of lenses. Moreover, at large propagation distances the quality of the generated GBBs significantly surpasses this of GBBs created by low angle axicons. The developed analytical model reproduces the experimental data. The presented method is flexible, easily realizable by using a spatial light modulator, does not require any special optical elements and, thus, is accessible in many laboratories.
Collapse
|
11
|
Cheng Z, Ma H, Wang Z, Yang S. In vivo volumetric monitoring of revascularization of traumatized skin using extended depth-of-field photoacoustic microscopy. FRONTIERS OF OPTOELECTRONICS 2020; 13:307-317. [PMID: 36641563 PMCID: PMC9743921 DOI: 10.1007/s12200-020-1040-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2020] [Accepted: 05/27/2020] [Indexed: 05/08/2023]
Abstract
Faster and better wound healing is a critical medical issue. Because the repair process of wounds is closely related to revascularization, accurate early assessment and postoperative monitoring are very important for establishing an optimal treatment plan. Herein, we present an extended depth-of-field photoacoustic microscopy system (E-DOF-PAM) that can achieve a constant spatial resolution and relatively uniform excitation efficiency over a long axial range. The superior performance of the system was verified by phantom and in vivo experiments. Furthermore, the system was applied to the imaging of normal and trauma sites of volunteers, and the experimental results accurately revealed the morphological differences between the normal and traumatized skin of the epidermis and dermis. These results demonstrated that the E-DOF-PAM is a powerful tool for observing and understanding the pathophysiology of cutaneous wound healing.
Collapse
Affiliation(s)
- Zhongwen Cheng
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China
| | - Haigang Ma
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China
| | - Zhiyang Wang
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China
| | - Sihua Yang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China.
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China.
| |
Collapse
|
12
|
Xiang F, Liu D, Xiao L, Shen S, Yang Z, Liu J, Wang K. Generation of a meter-scale THz diffraction-free beam based on multiple cascaded lens-axicon doublets: detailed analysis and experimental demonstration. OPTICS EXPRESS 2020; 28:36873-36883. [PMID: 33379771 DOI: 10.1364/oe.408692] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Accepted: 11/11/2020] [Indexed: 06/12/2023]
Abstract
An effective approach is proposed for obtaining a long-distance THz diffraction-free beam with meter-scale length. Multiple 3D-printed lens-axicon doublets are cascaded to form the generation system. In order to manifest the physical mechanism behind the generation process of this long-distance diffraction-free beam, we make a detailed comparative analysis of three beams: the ideal Bessel beam, the quasi-Bessel beam generated by single axicon, and the diffraction-free beam generated by the lens-axicon doublets. Theoretical results show that the zero-radial-spatial-frequency component plays a key role during the generation process of the third beam. Moreover, the intensities of this component are enhanced with the increase in the number of lens-axicon doublets, making the diffraction-free length longer. An experiment containing three lens-axicon doublets is performed to demonstrate the feasibility of our design. A 0.1-THz beam with one-meter diffraction-free length was successfully generated. Further experiments indicate that this THz diffraction-free beam also has a self-healing property. We believe that such long-distance diffraction-free beams can be used in practical THz remote sensing or imaging.
Collapse
|