1
|
Nankivil D, Cottaris NP, Brainard DH. Theoretical impact of chromatic aberration correction on visual acuity. BIOMEDICAL OPTICS EXPRESS 2024; 15:3265-3284. [PMID: 38855664 PMCID: PMC11161344 DOI: 10.1364/boe.516049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Revised: 03/29/2024] [Accepted: 04/03/2024] [Indexed: 06/11/2024]
Abstract
It has been known for more than 220 years that the image quality of the human eye is significantly degraded by chromatic aberrations. Recently, it was shown experimentally that correcting chromatic aberrations results in a 0.2- to 0.8-line improvement in visual acuity. Here we ask, is this expected? We developed tools that enable simulations of the optical impact of physiologically relevant amounts of chromatic aberration in real human eyes and combined these with tools that compute the visual acuity of an ideal observer. This allows us to characterize the theoretical impact of chromatic aberration correction on visual acuity. Results indicate a substantive improvement of 0.4- to 2-lines in ideal observer visual acuity with chromatic aberration correction. Ideal observer thresholds benefit significantly more from correction of longitudinal than correction of transverse chromatic aberration. Finally, improvements in ideal observer visual acuity are greater for subjects with less monochromatic aberration, such that subjects with better baseline optical quality benefit most from correction of chromatic aberrations.
Collapse
Affiliation(s)
- Derek Nankivil
- Johnson & Johnson Vision Care Inc., Research & Development, 7500 Centurion Parkway, Jacksonville, FL 32256, USA
| | - Nicolas P Cottaris
- Department of Psychology, University of Pennsylvania, Goddard Laboratories, Philadelphia, PA 19104, USA
| | - David H Brainard
- Department of Psychology, University of Pennsylvania, Goddard Laboratories, Philadelphia, PA 19104, USA
| |
Collapse
|
2
|
Soomro SR, Sager S, Paniagua-Diaz AM, Prieto PM, Artal P. Head-mounted adaptive optics visual simulator. BIOMEDICAL OPTICS EXPRESS 2024; 15:608-623. [PMID: 38404335 PMCID: PMC10890873 DOI: 10.1364/boe.506858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 12/22/2023] [Accepted: 12/26/2023] [Indexed: 02/27/2024]
Abstract
Adaptive optics visual simulation is a powerful tool for vision testing and evaluation. However, the existing instruments either have fixed tabletop configurations or, being wearable, only offer the correction of defocus. This paper proposes a novel head-mounted adaptive optics visual simulator that can measure and modify complex ocular aberrations in real-time. The prototype is composed of two optical modules, one for the objective assessment of aberrations and the second for wavefront modulation, all of which are integrated into a wearable headset. The device incorporates a microdisplay for stimulus generation, a liquid crystal on silicon (LCoS) spatial light modulator for wavefront manipulation, and a Hartmann-Shack wavefront sensor. Miniature optical components and optical path folding structures, together with in-house 3D printed mounts and housing, were adapted to realize the compact size. The system was calibrated by characterizing and compensating the internal aberrations of the visual relay. The performance of the prototype was analyzed by evaluating the measurement and compensation of low-order and higher-order aberrations induced through trial lenses and phase masks in an artificial eye. The defocus curves for a simulated bifocal diffractive lens were evaluated in real eyes. The results show high accuracy while measuring and compensating for the induced defocus, astigmatism, and higher-order aberrations, whereas the MTF analysis shows post-correction resolution of up to 37.5 cycles/degree (VA 1.25). Moreover, the subjective test results show the defocus curves closely matched to a commercial desktop visual simulator.
Collapse
Affiliation(s)
- Shoaib R. Soomro
- Voptica S.L., Campus de Espinardo (Edificio Pleiades), 30100 Murcia, Spain
- Electronic Engineering Department, Mehran University of Engineering and Technology, Pakistan
| | - Santiago Sager
- Voptica S.L., Campus de Espinardo (Edificio Pleiades), 30100 Murcia, Spain
- Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo (Edificio 34), 30100 Murcia, Spain
| | - Alba M. Paniagua-Diaz
- Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo (Edificio 34), 30100 Murcia, Spain
| | - Pedro M. Prieto
- Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo (Edificio 34), 30100 Murcia, Spain
| | - Pablo Artal
- Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo (Edificio 34), 30100 Murcia, Spain
| |
Collapse
|
3
|
Moon B, Poletti M, Roorda A, Tiruveedhula P, Liu SH, Linebach G, Rucci M, Rolland JP. Alignment, calibration, and validation of an adaptive optics scanning laser ophthalmoscope for high-resolution human foveal imaging. APPLIED OPTICS 2024; 63:730-742. [PMID: 38294386 PMCID: PMC11062499 DOI: 10.1364/ao.504283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Accepted: 12/26/2023] [Indexed: 02/01/2024]
Abstract
In prior art, advances in adaptive optics scanning laser ophthalmoscope (AOSLO) technology have enabled cones in the human fovea to be resolved in healthy eyes with normal vision and low to moderate refractive errors, providing new insight into human foveal anatomy, visual perception, and retinal degenerative diseases. These high-resolution ophthalmoscopes require careful alignment of each optical subsystem to ensure diffraction-limited imaging performance, which is necessary for resolving the smallest foveal cones. This paper presents a systematic and rigorous methodology for building, aligning, calibrating, and testing an AOSLO designed for imaging the cone mosaic of the central fovea in humans with cellular resolution. This methodology uses a two-stage alignment procedure and thorough system testing to achieve diffraction-limited performance. Results from retinal imaging of healthy human subjects under 30 years of age with refractive errors of less than 3.5 diopters using either 680 nm or 840 nm light show that the system can resolve cones at the very center of the fovea, the region where the cones are smallest and most densely packed.
Collapse
Affiliation(s)
- Benjamin Moon
- The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
- Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
| | - Martina Poletti
- Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
- Department of Brain and Cognitive Sciences, University of Rochester, Rochester, NY 14627, USA
- Department of Neuroscience, University of Rochester, Rochester, NY 14627, USA
| | - Austin Roorda
- Herbert Wertheim School of Optometry and Vision Science, University of California Berkeley, Berkeley, CA 94720, USA
| | - Pavan Tiruveedhula
- Herbert Wertheim School of Optometry and Vision Science, University of California Berkeley, Berkeley, CA 94720, USA
| | - Soh Hang Liu
- The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
- Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
| | - Glory Linebach
- The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
- Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
| | - Michele Rucci
- Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
- Department of Brain and Cognitive Sciences, University of Rochester, Rochester, NY 14627, USA
| | - Jannick P. Rolland
- The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
- Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627, USA
| |
Collapse
|
4
|
Doyle HK, Herbeck SR, Boehm AE, Vanston JE, Ng R, Tuten WS, Roorda A. Boosting 2-photon vision with adaptive optics. J Vis 2023; 23:4. [PMID: 37801322 PMCID: PMC10561787 DOI: 10.1167/jov.23.12.4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Accepted: 09/05/2023] [Indexed: 10/07/2023] Open
Abstract
The 2-photon effect in vision occurs when two photons of the same wavelength are absorbed by cone photopigment in the retina and create a visual sensation matching the appearance of light close to half their wavelength. This effect is especially salient for infrared light, where humans are mostly insensitive to 1-photon isomerizations and thus any perception is dominated by 2-photon isomerizations. This phenomenon can be made more readily visible using short-pulsed lasers, which increase the likelihood of 2-photon excitation by making photon arrivals at the retina more concentrated in time. Adaptive optics provides another avenue for enhancing the 2-photon effect by focusing light more tightly at the retina, thereby increasing the spatial concentration of incident photons. This article makes three contributions. First, we demonstrate through color-matching experiments that an adaptive optics correction can provide a 25-fold increase in the luminance of the 2-photon effect-a boost equivalent to reducing pulse width by 96%. Second, we provide image-based evidence that the 2-photon effect occurs at the photoreceptor level. Third, we use our results to compute the specifications for a system that could utilize 2-photon vision and adaptive optics to image and stimulate the retina using a single infrared wavelength and reach luminance levels comparable to conventional displays.
Collapse
Affiliation(s)
- Hannah K Doyle
- Department of Electrical Engineering and Computer Sciences, University of California Berkeley, Berkeley, CA, USA
| | - Sofie R Herbeck
- Department of Electrical Engineering and Computer Sciences, University of California Berkeley, Berkeley, CA, USA
| | - Alexandra E Boehm
- Herbert Wertheim School of Optometry and Vision Science, University of California Berkeley, Berkeley, CA, USA
| | - John E Vanston
- Herbert Wertheim School of Optometry and Vision Science, University of California Berkeley, Berkeley, CA, USA
| | - Ren Ng
- Department of Electrical Engineering and Computer Sciences, University of California Berkeley, Berkeley, CA, USA
| | - William S Tuten
- Herbert Wertheim School of Optometry and Vision Science, University of California Berkeley, Berkeley, CA, USA
| | - Austin Roorda
- Herbert Wertheim School of Optometry and Vision Science, University of California Berkeley, Berkeley, CA, USA
| |
Collapse
|
5
|
Schmidt K, Guo N, Wang W, Czarske J, Koukourakis N. Chromatic aberration correction employing reinforcement learning. OPTICS EXPRESS 2023; 31:16133-16147. [PMID: 37157699 DOI: 10.1364/oe.487045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
In fluorescence microscopy a multitude of labels are used that bind to different structures of biological samples. These often require excitation at different wavelengths and lead to different emission wavelengths. The presence of different wavelengths can induce chromatic aberrations, both in the optical system and induced by the sample. These lead to a detuning of the optical system, as the focal positions shift in a wavelength dependent manner and finally to a decrease in the spatial resolution. We present the correction of chromatic aberrations by using an electrical tunable achromatic lens driven by reinforcement learning. The tunable achromatic lens consists of two lens chambers filled with different optical oils and sealed with deformable glass membranes. By deforming the membranes of both chambers in a targeted manner, the chromatic aberrations present in the system can be manipulated to tackle both systematic and sample induced aberrations. We demonstrate chromatic aberration correction of up to 2200 mm and shift of the focal spot positions of 4000 mm. For control of this non-linear system with four input voltages, several reinforcement learning agents are trained and compared. The experimental results show that the trained agent can correct system and sample induced aberration and thereby improve the imaging quality, this is demonstrated using biomedical samples. In this case human thyroid was used for demonstration.
Collapse
|
6
|
Roorda A, Cholewiak SA, Bhargava S, Ivzan NH, LaRocca F, Nankivil D, Banks MS. The visual benefits of correcting longitudinal and transverse chromatic aberration. J Vis 2023; 23:3. [PMID: 36729421 PMCID: PMC9907370 DOI: 10.1167/jov.23.2.3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
We describe a system-the Binocular Varichrome and Accommodation Measurement System-that can be used to measure and correct the eye's longitudinal and transverse chromatic aberration (LCA and TCA) and to perform vision tests with custom corrections. We used the system to investigate how LCA and TCA affect visual performance. Specifically, we studied the effects of LCA and TCA on visual acuity, contrast sensitivity, and chromostereopsis. LCA exhibited inter subject variability but followed expected trends compared with previous reports. TCA at the fovea was variable between individuals but with a tendency for the shift at shorter wavelengths to be more temporalward in the visual field in each eye. We found that TCA was generally greater when LCA was corrected. For visual acuity, we found that a measurable benefit was realized only with both LCA and TCA correction unless the TCA was low. For contrast sensitivity, we found that the best sensitivity to a 10-cycle/degree polychromatic grating was attained when LCA and TCA were corrected. Finally, we found that the primary cause of chromostereopsis is the TCA of the eyes.
Collapse
Affiliation(s)
- Austin Roorda
- Herbert Wertheim School of Optometry and Vision Science, University of California at Berkeley, Berkeley, CA, USA., https://roorda.vision.berkeley.edu
| | - Steven A. Cholewiak
- Herbert Wertheim School of Optometry and Vision Science, University of California at Berkeley, Berkeley, CA, USA,
| | - Swati Bhargava
- Herbert Wertheim School of Optometry and Vision Science, University of California at Berkeley, Berkeley, CA, USA.,
| | - Nadav H. Ivzan
- Herbert Wertheim School of Optometry and Vision Science, University of California at Berkeley, Berkeley, CA, USA,
| | - Francesco LaRocca
- Herbert Wertheim School of Optometry and Vision Science, University of California at Berkeley, Berkeley, CA, USA.,
| | - Derek Nankivil
- Johnson & Johnson Vision Care, Research & Development, Jacksonville, FL, USA., https://www.jjvision.com/
| | - Martin S. Banks
- Herbert Wertheim School of Optometry and Vision Science, University of California at Berkeley, Berkeley, CA, USA,https://civo.berkeley.edu/biographies/martin-s-banks
| |
Collapse
|
7
|
Marcos S, Artal P, Atchison DA, Hampson K, Legras R, Lundström L, Yoon G. Adaptive optics visual simulators: a review of recent optical designs and applications [Invited]. BIOMEDICAL OPTICS EXPRESS 2022; 13:6508-6532. [PMID: 36589577 PMCID: PMC9774875 DOI: 10.1364/boe.473458] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Revised: 10/26/2022] [Accepted: 10/27/2022] [Indexed: 05/02/2023]
Abstract
In their pioneering work demonstrating measurement and full correction of the eye's optical aberrations, Liang, Williams and Miller, [JOSA A14, 2884 (1997)10.1364/JOSAA.14.002884] showed improvement in visual performance using adaptive optics (AO). Since then, AO visual simulators have been developed to explore the spatial limits to human vision and as platforms to test non-invasively optical corrections for presbyopia, myopia, or corneal irregularities. These applications have allowed new psychophysics bypassing the optics of the eye, ranging from studying the impact of the interactions of monochromatic and chromatic aberrations on vision to neural adaptation. Other applications address new paradigms of lens designs and corrections of ocular errors. The current paper describes a series of AO visual simulators developed in laboratories around the world, key applications, and current trends and challenges. As the field moves into its second quarter century, new available technologies and a solid reception by the clinical community promise a vigorous and expanding use of AO simulation in years to come.
Collapse
Affiliation(s)
- Susana Marcos
- Center for Visual Sciences; The Institute of Optics and Flaum Eye Institute, University of Rochester, New York 14642, USA
| | - Pablo Artal
- Laboratorio de Optica, Universidad de Murcia, Campus Universitario de Espinardo, 30100, Spain
| | - David A. Atchison
- Centre for Vision and Eye Research, Queensland University of Technology, Brisbane Q, 4059, Australia
| | - Karen Hampson
- Department of Optometry, University of Manchester, Manchester M13 9PL, UK
| | - Richard Legras
- LuMIn, CNRS, ENS Paris-Saclay, Université Paris-Saclay, CentraleSupelec, Université Paris-Saclay Orsay, 91400, France
| | - Linda Lundström
- KTH (Royal Institute of Technology), Stockholm, 10691, Sweden
| | - Geunyoung Yoon
- College of Optometry, University of Houston, Houston, 77004, USA
| |
Collapse
|
8
|
Jiang X, Liu T, Pandiyan VP, Slezak E, Sabesan R. Coarse-scale optoretinography (CoORG) with extended field-of-view for normative characterization. BIOMEDICAL OPTICS EXPRESS 2022; 13:5989-6002. [PMID: 36733759 PMCID: PMC9872880 DOI: 10.1364/boe.473475] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Revised: 10/04/2022] [Accepted: 10/11/2022] [Indexed: 05/02/2023]
Abstract
Optoretinography (ORG) has the potential to be an effective biomarker for light-evoked retinal activity owing to its sensitive, objective, and precise localization of retinal function and dysfunction. Many ORG implementations have used adaptive optics (AO) to localize activity on a cellular scale. However, the use of AO restricts field-of-view (FOV) to the isoplanatic angle, necessitating the montaging of multiple regions-of-interest to cover an extended field. In addition, subjects with lens opacities, increased eye movements and decreased mobility pose challenges for effective AO operation. Here, we developed a coarse-scale ORG (CoORG) system without AO, which accommodates FOVs up to 5.5 deg. in a single acquisition. The system is based on a line-scan spectral domain OCT with volume rates of up to 32 Hz (16,000 B-frames per second). For acquiring ORGs, 5.5 deg. wide OCT volumes were recorded after dark adaptation and two different stimulus bleaches. The stimulus-evoked optical phase change was calculated from the reflections encasing the cone outer segments and its variation was assessed vs. eccentricity in 12 healthy subjects. The general behavior of ΔOPL vs. time mimicked published reports. High trial-to-trial repeatability was observed across subjects and with eccentricity. Comparison of ORG between CoORG and AO-OCT based ORG at 1.5°, 2.5°, and 3.5° eccentricity showed an excellent agreement in the same 2 subjects. The amplitude of the ORG response decreased with increasing eccentricity. The variation of ORG characteristics between subjects and versus eccentricity was well explained by the photon density of the stimulus on the retina and the outer segment length. Overall, the high repeatability and rapid acquisition over an extended field enabled the normative characterization of the cone ORG response in healthy eyes, and provides a promising avenue for translating ORG for widespread clinical application.
Collapse
Affiliation(s)
- Xiaoyun Jiang
- Department of Ophthalmology, University of Washington School of Medicine, Seattle, WA 98109, USA
| | - Teng Liu
- Department of Ophthalmology, University of Washington School of Medicine, Seattle, WA 98109, USA
- Department of Bioengineering, University of Washington, Seattle, WA 98195, USA
| | - Vimal Prabhu Pandiyan
- Department of Ophthalmology, University of Washington School of Medicine, Seattle, WA 98109, USA
| | - Emily Slezak
- Department of Ophthalmology, University of Washington School of Medicine, Seattle, WA 98109, USA
| | - Ramkumar Sabesan
- Department of Ophthalmology, University of Washington School of Medicine, Seattle, WA 98109, USA
| |
Collapse
|
9
|
Human cone elongation responses can be explained by photoactivated cone opsin and membrane swelling and osmotic response to phosphate produced by RGS9-catalyzed GTPase. Proc Natl Acad Sci U S A 2022; 119:e2202485119. [PMID: 36122241 PMCID: PMC9522364 DOI: 10.1073/pnas.2202485119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Optical coherence tomography has established that human cone photoreceptor outer segments elongate in response to stimuli bleaching large fractions of their visual pigment. Elongation responses are completely described over their 200-fold bleaching range as the sum of two exponentially rising components differing 13-fold in time constants and 4-fold in light sensitivity. Bleaching measurements of individual cones with adaptive optics scanning laser ophthalmoscopy (SLO) suggest that component 2 arises from cone opsin and disk membrane swelling triggered by photoactivation. Application of a model of phototransduction suggests that component 1 corresponds to free phosphate generated by regulator of G-protein signaling 9 (RGS9)-catalyzed hydrolysis of guanosine triphosphate (GTP) in the α-subunit of G protein complexed with phosphodiesterase. Human cone outer segment (COS) length changes in response to stimuli bleaching up to 99% of L- and M-cone opsins were measured with high resolution, phase-resolved optical coherence tomography (OCT). Responses comprised a fast phase (∼5 ms), during which COSs shrink, and two slower phases (1.5 s), during which COSs elongate. The slower components saturated in amplitude (∼425 nm) and initial rate (∼3 nm ms−1) and are well described over the 200-fold bleaching range as the sum of two exponentially rising functions with time constants of 80 to 90 ms (component 1) and 1,000 to 1,250 ms (component 2). Measurements with adaptive optics reflection densitometry revealed component 2 to be linearly related to cone pigment bleaching, and the hypothesis is proposed that it arises from cone opsin and disk membrane swelling triggered by isomerization and rate-limited by chromophore hydrolysis and its reduction to membrane-localized all-trans retinol. The light sensitivity and kinetics of component 1 suggested that the underlying mechanism is an osmotic response to an amplified soluble by-product of phototransduction. The hypotheses that component 1 corresponds to G-protein subunits dissociating from the membrane, metabolites of cyclic guanosine monophosphate (cGMP) hydrolysis, or by-products of activated guanylate cyclase are rejected, while the hypothesis that it corresponds to phosphate produced by regulator of G-protein signaling 9 (RGS9)-catalyzed hydrolysis of guanosine triphosphate (GTP) in G protein–phosphodiesterase complexes was found to be consistent with the results. These results provide a basis for the assessment with optoretinography of phototransduction in individual cone photoreceptors in health and during disease progression and therapeutic interventions.
Collapse
|
10
|
Calderon-Uribe U, Hernandez-Gomez G, Gomez-Vieyra A. Measurement of Longitudinal Chromatic Aberration in the Last Crystalline Lens Surface Using Hartmann Test and Purkinje Images. SENSORS 2022; 22:s22072653. [PMID: 35408266 PMCID: PMC9002912 DOI: 10.3390/s22072653] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/29/2022] [Revised: 03/23/2022] [Accepted: 03/27/2022] [Indexed: 12/10/2022]
Abstract
Research has shown that longitudinal chromatic aberration (LCA) of the human eye is generated across all of the eye's optical surfaces. However, it may not be necessary to measure the LCA from the first surface of the cornea to the retina, as it is known that most of the changes that can modify the path of light occur from the first surface of the cornea to the last surface of the crystalline lens. This investigation presents the study of an objective technique that allows the measurement of longitudinal chromatic aberration (LCA) on the last crystalline lens surface by developing a pulse width wavefront system using a Hartmann test, Purkinje image, and Zernike polynomial. A blue pulse (440-480 nm) and a red pulse (580-640 nm) were used to generate a pattern of spots in the human eye. This pattern generated on the posterior surface of the crystalline lens of the human eye allows the reconstruction of the wavefront via a modal method with Zernike polynomials. Once the wavefront is reconstructed, Zernike coefficients can be used to quantify the LCA. The methodology and objective measurements of the magnitude of the longitudinal chromatic aberration of five test subjects are explained in this article.
Collapse
Affiliation(s)
- Uriel Calderon-Uribe
- Multidisciplinary Studies Department, Engineering Division, Campus Irapuato-Salamanca, University of Guanajuato, Guanajuato 38944, Mexico;
| | - Geovanni Hernandez-Gomez
- Multidisciplinary Studies Department, Engineering Division, Campus Irapuato-Salamanca, University of Guanajuato, Guanajuato 38944, Mexico;
- Correspondence:
| | - Armando Gomez-Vieyra
- Laboratorio de Sistemas Complejos, Departamento de Ciencias Básicas, Universidad Autónoma Metropolitana, Unidad Azcapotzalco, Av. San Pablo 180, Ciudad de México 02200, Mexico;
| |
Collapse
|
11
|
Coates DR, Jiang X, Levi DM, Sabesan R. Cortical distance unifies the extent of parafoveal contour interactions. J Vis 2022; 22:15. [PMID: 35195672 PMCID: PMC8883158 DOI: 10.1167/jov.22.2.15] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Accepted: 01/18/2022] [Indexed: 11/24/2022] Open
Abstract
It is well known that crowding, the disruptive influence of flanking items on identification of targets, is the primary limiting factor to object identification in the periphery, while limits in the fovea are more determined by the ability to resolve individual items. Whether this is a dichotomous or merely a quantitative difference, and the transition between these two regimes, has remained unexplained. Here, using an adaptive optics system for optimal control of optical and stimulus factors, we measured threshold acuity for identification of Tumbling Es flanked by bars at a variety of flanker spacings and eight eccentricities in the parafovea. Thresholds at each eccentricity were influenced by resolution, contour interaction, and a saturating pedestal effect. When target-flanker spacing was plotted in terms of cortical distance, a single canonical clipped-line fit unified the resultant curves. The critical spacing for letters flanked by bars was found to be 1.3 to 1.5 cortical millimeters, corresponding to approximately 0.1*E outside the fovea.
Collapse
Affiliation(s)
- Daniel R Coates
- College of Optometry, University of Houston, Houston, TX, USA
| | - Xiaoyun Jiang
- Department of Ophthalmology, University of Washington School of Medicine, Seattle, WA, USA
| | - Dennis M Levi
- Herbert Wertheim School of Optometry & Vision Science, Helen Wills Neuroscience Institute, University of California, Berkeley, Berkeley, CA, USA
| | - Ramkumar Sabesan
- Department of Ophthalmology, University of Washington School of Medicine, Seattle, WA, USA
| |
Collapse
|
12
|
Aissati S, Vinas M, Benedi-Garcia C, Dorronsoro C, Marcos S. Testing the effect of ocular aberrations in the perceived transverse chromatic aberration. BIOMEDICAL OPTICS EXPRESS 2020; 11:4052-4068. [PMID: 32923028 PMCID: PMC7449748 DOI: 10.1364/boe.396469] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 06/14/2020] [Accepted: 06/16/2020] [Indexed: 05/06/2023]
Abstract
We have measured the ocular transverse chromatic aberration (TCA) in 11 subjects using 2D-two-color Vernier alignment, for two pupil diameters, in a polychromatic adaptive optics (AO) system. TCA measurements were performed for two pupil diameters: for a small pupil (2-mm), referred to as 'optical TCA' (oTCA), and for a large pupil (6-mm), referred to 'perceived TCA' (pTCA). Also, the TCA was measured through both natural aberrations (HOAs) and AO-corrected aberrations. Computer simulations of pTCA incorporated longitudinal chromatic aberration (LCA), the patient's HOAs measured with Hartmann-Shack, and the Stiles-Crawford effect (SCE), measured objectively by laser ray tracing. The oTCA and the simulated pTCA (no aberrations) were shifted nasally 1.20 arcmin and 1.40 arcmin respectively. The experimental pTCA (-0.27 arcmin horizontally and -0.62 vertically) was well predicted (81%) by simulations when both the individual HOAs and SCE were considered. Both HOAs and SCE interact with oTCA, reducing it in magnitude and changing its orientation. The results indicate that estimations of polychromatic image quality should incorporate patient's specific data of HOAs, LCA, TCA & SCE.
Collapse
Affiliation(s)
- Sara Aissati
- Instituto de Óptica "Daza de Valdés", Consejo Superior de Investigaciones Científicas, IO-CSIC, Serrano, 121, Madrid 28006, Spain
| | - Maria Vinas
- Instituto de Óptica "Daza de Valdés", Consejo Superior de Investigaciones Científicas, IO-CSIC, Serrano, 121, Madrid 28006, Spain
| | - Clara Benedi-Garcia
- Instituto de Óptica "Daza de Valdés", Consejo Superior de Investigaciones Científicas, IO-CSIC, Serrano, 121, Madrid 28006, Spain
| | - Carlos Dorronsoro
- Instituto de Óptica "Daza de Valdés", Consejo Superior de Investigaciones Científicas, IO-CSIC, Serrano, 121, Madrid 28006, Spain
| | - Susana Marcos
- Instituto de Óptica "Daza de Valdés", Consejo Superior de Investigaciones Científicas, IO-CSIC, Serrano, 121, Madrid 28006, Spain
| |
Collapse
|
13
|
Camino A, Ng R, Huang J, Guo Y, Ni S, Jia Y, Huang D, Jian Y. Depth-resolved optimization of a real-time sensorless adaptive optics optical coherence tomography. OPTICS LETTERS 2020; 45:2612-2615. [PMID: 32356829 DOI: 10.1364/ol.390134] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Accepted: 04/07/2020] [Indexed: 05/18/2023]
Abstract
Sensorless adaptive optics optical coherence tomography (AO-OCT) is a technology to image retinal tissue with high resolution by compensating ocular aberrations without wavefront sensors. In this Letter, a fast and robust hill-climbing algorithm is developed to optimize five Zernike modes in AO-OCT with a numerical aperture between that of conventional AO and commercial OCT systems. The merit function is generated in real time using graphics processing unit while axially tracking the retinal layer of interest. A new method is proposed to estimate the largest achievable field of view for which aberrations are corrected uniformly in sensorless AO-OCT.
Collapse
|
14
|
Neitz A, Jiang X, Kuchenbecker JA, Domdei N, Harmening W, Yan H, Yeonan-Kim J, Patterson SS, Neitz M, Neitz J, Coates DR, Sabesan R. Effect of cone spectral topography on chromatic detection sensitivity. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2020; 37:A244-A254. [PMID: 32400553 PMCID: PMC7231539 DOI: 10.1364/josaa.382384] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2019] [Accepted: 03/06/2020] [Indexed: 05/06/2023]
Abstract
The spatial and spectral topography of the cone mosaic set the limits for detection and discrimination of chromatic sinewave gratings. Here, we sought to compare the spatial characteristics of mechanisms mediating hue perception against those mediating chromatic detection in individuals with known spectral topography and with optical aberrations removed with adaptive optics. Chromatic detection sensitivity in general exceeded previous measurements and decreased monotonically for increasingly skewed cone spectral compositions. The spatial grain of hue perception was significantly coarser than chromatic detection, consistent with separate neural mechanisms for color vision operating at different spatial scales.
Collapse
Affiliation(s)
- Alexandra Neitz
- Department of Ophthalmology, University of Washington, Seattle, Washington 98195, USA
| | - Xiaoyun Jiang
- Department of Ophthalmology, University of Washington, Seattle, Washington 98195, USA
| | - James A. Kuchenbecker
- Department of Ophthalmology, University of Washington, Seattle, Washington 98195, USA
| | - Niklas Domdei
- Department of Ophthalmology, University of Bonn, Bonn, Germany
| | - Wolf Harmening
- Department of Ophthalmology, University of Bonn, Bonn, Germany
| | - Hongyi Yan
- Department of Ophthalmology, University of Washington, Seattle, Washington 98195, USA
| | - Jihyun Yeonan-Kim
- Department of Ophthalmology, University of Washington, Seattle, Washington 98195, USA
| | - Sara S. Patterson
- Department of Ophthalmology, University of Washington, Seattle, Washington 98195, USA
| | - Maureen Neitz
- Department of Ophthalmology, University of Washington, Seattle, Washington 98195, USA
| | - Jay Neitz
- Department of Ophthalmology, University of Washington, Seattle, Washington 98195, USA
| | - Daniel R. Coates
- College of Optometry, University of Houston, Houston, Texas 77004, USA
| | - Ramkumar Sabesan
- Department of Ophthalmology, University of Washington, Seattle, Washington 98195, USA
| |
Collapse
|
15
|
Mozaffari S, LaRocca F, Jaedicke V, Tiruveedhula P, Roorda A. Wide-vergence, multi-spectral adaptive optics scanning laser ophthalmoscope with diffraction-limited illumination and collection. BIOMEDICAL OPTICS EXPRESS 2020; 11:1617-1632. [PMID: 32206432 PMCID: PMC7075605 DOI: 10.1364/boe.384229] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Revised: 02/11/2020] [Accepted: 02/15/2020] [Indexed: 05/06/2023]
Abstract
Visualizing and assessing the function of microscopic retinal structures in the human eye is a challenging task that has been greatly facilitated by ophthalmic adaptive optics (AO). Yet, as AO imaging systems advance in functionality by employing multiple spectral channels and larger vergence ranges, achieving optimal resolution and signal-to-noise ratios (SNR) becomes difficult and is often compromised. While current-generation AO retinal imaging systems have demonstrated excellent, near diffraction-limited imaging performance over wide vergence and spectral ranges, a full theoretical and experimental analysis of an AOSLO that includes both the light delivery and collection optics has not been done, and neither has the effects of extending wavefront correction from one wavelength to imaging performance in different spectral channels. Here, we report a methodology and system design for simultaneously achieving diffraction-limited performance in both the illumination and collection paths for a wide-vergence, multi-spectral AO scanning laser ophthalmoscope (SLO) over a 1.2 diopter vergence range while correcting the wavefront in a separate wavelength. To validate the design, an AOSLO was constructed to have three imaging channels spanning different wavelength ranges (543 ± 11 nm, 680 ± 11 nm, and 840 ± 6 nm, respectively) and one near-infrared wavefront sensing channel (940 ± 5 nm). The AOSLO optics and their alignment were determined via simulations in optical and optomechanical design software and then experimentally verified by measuring the AOSLO's illumination and collection point spread functions (PSF) for each channel using a phase retrieval technique. The collection efficiency was then measured for each channel as a function of confocal pinhole size when imaging a model eye achieving near-theoretical performance. Imaging results from healthy human adult volunteers demonstrate the system's ability to resolve the foveal cone mosaic in all three imaging channels despite a wide spectral separation between the wavefront sensing and imaging channels.
Collapse
Affiliation(s)
- Sanam Mozaffari
- School of Optometry and Vision Science Graduate Group, University of California Berkeley; Berkeley, CA 94720, USA
- Contributed equally to this work
| | - Francesco LaRocca
- School of Optometry and Vision Science Graduate Group, University of California Berkeley; Berkeley, CA 94720, USA
- Contributed equally to this work
| | - Volker Jaedicke
- School of Optometry and Vision Science Graduate Group, University of California Berkeley; Berkeley, CA 94720, USA
| | - Pavan Tiruveedhula
- School of Optometry and Vision Science Graduate Group, University of California Berkeley; Berkeley, CA 94720, USA
| | - Austin Roorda
- School of Optometry and Vision Science Graduate Group, University of California Berkeley; Berkeley, CA 94720, USA
| |
Collapse
|
16
|
Suchkov N, Fernández EJ, Artal P. Impact of longitudinal chromatic aberration on through-focus visual acuity. OPTICS EXPRESS 2019; 27:35935-35947. [PMID: 31878758 DOI: 10.1364/oe.27.035935] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
An enhanced adaptive optics visual simulator (AOVS) was used to study the impact of chromatic aberration on vision. In particular, through-focus visual acuity (VA) was measured in four subjects under three longitudinal chromatic aberration (LCA) conditions: natural LCA, compensated LCA and doubled LCA. Ray-tracing simulations using a chromatic eye model were also performed for a better understanding of experimental results. Simulations predicted the optical quality of the retinal images and VA by applying a semi-empirical formula. Experimental and ray tracing results showed a significant agreement in the natural LCA case (R2 = 0.92). Modifying the LCA caused an impairment in the predictability of the results, with decreasing correlations between experiment and simulations (compensated LCA, R2 = 0.84; doubled LCA, R2 = 0.59). VA under modified LCA was systematically overestimated by the model around the best focus position. The results provided useful information on how LCA manipulation affects the depth of focus. Decreased capability of the model to predict VA in modified LCA conditions suggests that neural adaptation may play a role.
Collapse
|