Chen XH, Cai MQ, Ouyang XK, Jin MC. Ion chromatography tandem mass spectrometry for simultaneous confirmation and determination of indandione rodenticides in serum.
Biomed Chromatogr 2009;
23:1217-26. [PMID:
19488975 DOI:
10.1002/bmc.1246]
[Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
This paper describes a simple method for the simultaneous determination and confirmation of the indandione rodenticides in serum. After samples were extracted with 10% (v/v) methanol in acetonitrile and cleaned by solid-phase extraction, chromatographic separation was performed on an IonPac AS11 analytical column (250 x 4.0 mm) using gradient KOH eluent with 10% (v/v) methanol as organic modifier. Confirmation was depended on the extensive fragmentation of the indandione molecule under MS/MS conditions which provides sufficient structural information. Quantification was performed by negative electrospray ionization in multiple reaction monitoring mode. All the method parameters were validated. It was confirmed that this method could be used in clinical diagnosis and forensic toxicology.
Collapse