1
|
Cometta S, Jones RT, Juárez-Saldivar A, Donose BC, Yasir M, Bock N, Dargaville TR, Bertling K, Brünig M, Rakić AD, Willcox M, Hutmacher DW. Melimine-Modified 3D-Printed Polycaprolactone Scaffolds for the Prevention of Biofilm-Related Biomaterial Infections. ACS NANO 2022; 16:16497-16512. [PMID: 36245096 PMCID: PMC9620410 DOI: 10.1021/acsnano.2c05812] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Accepted: 09/28/2022] [Indexed: 06/16/2023]
Abstract
Biomaterial-associated infections are one of the major causes of implant failure. These infections result from persistent bacteria that have adhered to the biomaterial surface before, during, or after surgery and have formed a biofilm on the implant's surface. It is estimated that 4 to 10% of implant surfaces are contaminated with bacteria; however, the infection rate can be as high as 30% in intensive care units in developed countries and as high as 45% in developing countries. To date, there is no clinical solution to prevent implant infection without relying on the use of high doses of antibiotics supplied systemically and/or removal of the infected device. In this study, melimine, a chimeric cationic peptide that has been tested in Phase I and II human clinical trials, was immobilized onto the surface of 3D-printed medical-grade polycaprolactone (mPCL) scaffolds via covalent binding and adsorption. X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS) spectra of melimine-treated surfaces confirmed immobilization of the peptide, as well as its homogeneous distribution throughout the scaffold surface. Amino acid analysis showed that melimine covalent and noncovalent immobilization resulted in a peptide density of ∼156 and ∼533 ng/cm2, respectively. Furthermore, we demonstrated that the immobilization of melimine on mPCL scaffolds by 1-ethyl-3-[3-(dimethylamino)propyl] carbodiimide hydrochloride (EDC) coupling and noncovalent interactions resulted in a reduction of Staphylococcus aureus colonization by 78.7% and 76.0%, respectively, in comparison with the nonmodified control specimens. Particularly, the modified surfaces maintained their antibacterial properties for 3 days, which resulted in the inhibition of biofilm formation in vitro. This system offers a biomaterial strategy to effectively prevent biofilm-related infections on implant surfaces without relying on the use of prophylactic antibiotic treatment.
Collapse
Affiliation(s)
- Silvia Cometta
- Faculty
of Engineering, School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, QLD 4000, Australia
- Australian
Research Council Training Centre for Multiscale 3D Imaging, Modelling
and Manufacturing (M3D Innovation), Queensland
University of Technology, Kelvin
Grove, QLD 4059, Australia
- Max
Planck Queensland Centre, Queensland University
of Technology, Brisbane, QLD 4000, Australia
| | - Robert T. Jones
- Central
Analytical Research Facility (CARF), Queensland
University of Technology, Brisbane, QLD 4000, Australia
- Centre
for Materials Science, School of Chemistry and Physics, Queensland University of Technology, Brisbane, QLD 4000, Australia
| | - Alfredo Juárez-Saldivar
- Unidad Académica
Multidisciplinaria Reynosa Aztlán, Universidad Autónoma de Tamaulipas, Reynosa 88740, Mexico
| | - Bogdan C. Donose
- School
of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, QLD 4072, Australia
| | - Muhammad Yasir
- School
of Optometry and Vision Science, University
of New South Wales, Sydney, NSW 2033, Australia
| | - Nathalie Bock
- Australian
Research Council Training Centre for Multiscale 3D Imaging, Modelling
and Manufacturing (M3D Innovation), Queensland
University of Technology, Kelvin
Grove, QLD 4059, Australia
- Max
Planck Queensland Centre, Queensland University
of Technology, Brisbane, QLD 4000, Australia
- Faculty
of Health, School of Biomedical Sciences, Queensland University of Technology, Brisbane, QLD 4000, Australia
- Translational Research
Institute, Woolloongabba, QLD 4102, Australia
| | - Tim R. Dargaville
- Centre
for Materials Science, School of Chemistry and Physics, Queensland University of Technology, Brisbane, QLD 4000, Australia
| | - Karl Bertling
- School
of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, QLD 4072, Australia
| | - Michael Brünig
- School
of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, QLD 4072, Australia
| | - Aleksandar D. Rakić
- School
of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, QLD 4072, Australia
| | - Mark Willcox
- School
of Optometry and Vision Science, University
of New South Wales, Sydney, NSW 2033, Australia
| | - Dietmar W. Hutmacher
- Faculty
of Engineering, School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, QLD 4000, Australia
- Australian
Research Council Training Centre for Multiscale 3D Imaging, Modelling
and Manufacturing (M3D Innovation), Queensland
University of Technology, Kelvin
Grove, QLD 4059, Australia
- Max
Planck Queensland Centre, Queensland University
of Technology, Brisbane, QLD 4000, Australia
- Translational Research
Institute, Woolloongabba, QLD 4102, Australia
- Australian
Research Council Industrial Transformation Training Centre in Additive
Biomanufacturing, Queensland University
of Technology, Brisbane, QLD 4059, Australia
- Australian
Research Council Training Centre for Cell and Tissue Engineering Technologies, Queensland University of Technology, Brisbane, QLD 4059, Australia
| |
Collapse
|
2
|
Lux L, Phal Y, Hsieh PH, Bhargava R. On the Limit of Detection in Infrared Spectroscopic Imaging. APPLIED SPECTROSCOPY 2022; 76:105-117. [PMID: 34643135 PMCID: PMC10539114 DOI: 10.1177/00037028211050961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Infrared (IR) spectroscopic imaging instruments' performance can be characterized and optimized by an analysis of their limit of detection (LOD). Here we report a systematic analysis of the LOD for Fourier transform IR (FT-IR) and discrete frequency IR (DFIR) imaging spectrometers. In addition to traditional measurements of sample and blank data, we propose a decision theory perspective to pose the determination of LOD as a binary classification problem under different assumptions of noise uniformity and correlation. We also examine three spectral analysis approaches, namely, absorbance at a single frequency, average of absorbance over selected frequencies and total spectral distance - to suit instruments that acquire discrete or contiguous spectral bandwidths. The analysis is validated by refining the fabrication of a bovine serum albumin protein microarray to provide eight uniform spots from ∼2.8 nL of solution for each concentration over a wide range (0.05-10 mg/mL). Using scanning parameters that are typical for each instrument, we estimate a LOD of 0.16 mg/mL and 0.12 mg/mL for widefield and line scanning FT-IR imaging systems, respectively, using the spectral distance approach, and 0.22 mg/mL and 0.15 mg/mL using an optimal set of discrete frequencies. As expected, averaging and the use of post-processing techniques such as minimum noise fraction transformation results in LODs as low as ∼0.075 mg/mL that correspond to a spotted protein mass of ∼112 fg/pixel. We emphasize that these measurements were conducted at typical imaging parameters for each instrument and can be improved using the usual trading rules of IR spectroscopy. This systematic analysis and methodology for determining the LOD can allow for quantitative measures of confidence in imaging an analyte's concentration and a basis for further improving IR imaging technology.
Collapse
Affiliation(s)
- Laurin Lux
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Yamuna Phal
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Pei-Hsuan Hsieh
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Rohit Bhargava
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
- Deparment of Mechanical Science and Engineering, Chemical and Biomolecular Engineering, and Chemistry, University of Illinois at Urbana-Champaign, Urbana, IL, USA
- Cancer Center at Illinois, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| |
Collapse
|
3
|
Pandiselvam R, Sruthi NU, Kumar A, Kothakota A, Thirumdas R, Ramesh S, Cozzolino D. Recent Applications of Vibrational Spectroscopic Techniques in the Grain Industry. FOOD REVIEWS INTERNATIONAL 2021. [DOI: 10.1080/87559129.2021.1904253] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Affiliation(s)
- R. Pandiselvam
- Physiology,Biochemistry and Post Harvest Technology Division, ICAR –Central Plantation Crops Research Institute, Kasaragod, India
| | - N. U. Sruthi
- Agricultural and Food Engineering Department, Indian Institute of Technology (IIT), Kharagpur, India
| | - Ankit Kumar
- Agricultural and Food Engineering Department, Indian Institute of Technology (IIT), Kharagpur, India
| | - Anjineyulu Kothakota
- Agro-Processing & Technology Division, CSIR-National Institute for Interdisciplinary Science and Technology (NIIST), Trivandrum, India
| | - Rohit Thirumdas
- Department of Food Process Technology, College of Food Science & Technology, Telangana, India
| | - S.V. Ramesh
- Physiology,Biochemistry and Post Harvest Technology Division, ICAR –Central Plantation Crops Research Institute, Kasaragod, India
| | - Daniel Cozzolino
- Centre for Nutrition and Food Sciences, Queensland Alliance for Agriculture and Food Innovation (QAAFI), the University of Queensland, Brisbane, Australia
| |
Collapse
|
4
|
Rak D, Sedlák M. Comment on "Bulk Nanobubbles or Not Nanobubbles: That is the Question". LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2020; 36:15618-15621. [PMID: 33325226 DOI: 10.1021/acs.langmuir.0c01614] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
In a recent article, Jadhav and Barigou ( Langmuir 2020, 36 (7), 1699-1708) investigated the question of the existence of stable bulk nanobubbles in water generated by hydrodynamic cavitation, ultrasound cavitation, and the addition of an organic compound (namely, ethanol) to water. They firmly conclude that these procedures result in stable bulk nanobubbles. However, a number of previous works documented that the nanoentities observed in water upon such procedures are not nanobubbles. Here, we analyze work of Jadhav and Barigou and show that conclusions regarding the nanobubble nature of the nanoentities are incorrect and are due to the choice of experimental techniques with weak sensitivity, methodical issues in the use of otherwise proper experimental techniques, and ambiguous outcomes of the rest of experiments.
Collapse
Affiliation(s)
- Dmytro Rak
- Institute of Experimental Physics, Slovak Academy of Sciences, Watsonova 47, 040 01 Košice, Slovakia
| | - Marián Sedlák
- Institute of Experimental Physics, Slovak Academy of Sciences, Watsonova 47, 040 01 Košice, Slovakia
| |
Collapse
|
6
|
Winner TL, Lanzarotta A, Sommer AJ. Analysis of Counterfeit Coated Tablets and Multi-Layer Packaging Materials Using Infrared Microspectroscopic Imaging. MICROSCOPY AND MICROANALYSIS : THE OFFICIAL JOURNAL OF MICROSCOPY SOCIETY OF AMERICA, MICROBEAM ANALYSIS SOCIETY, MICROSCOPICAL SOCIETY OF CANADA 2016; 22:649-655. [PMID: 27068491 DOI: 10.1017/s143192761600060x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
An effective method for detecting and characterizing counterfeit finished dosage forms and packaging materials is described in this study. Using attenuated total internal reflection Fourier transform infrared spectroscopic imaging, suspect tablet coating and core formulations as well as multi-layered foil safety seals, bottle labels, and cigarette tear tapes were analyzed and compared directly with those of a stored authentic product. The approach was effective for obtaining molecular information from structures as small as 6 μm.
Collapse
Affiliation(s)
- Taryn L Winner
- 1Molecular Microspectroscopy Laboratory,Department of Chemistry and Biochemistry,Miami University,Oxford,Ohio,USA
| | - Adam Lanzarotta
- 2United States Food and Drug Administration Forensic Chemistry Center,Cincinnati,Ohio,USA
| | - André J Sommer
- 1Molecular Microspectroscopy Laboratory,Department of Chemistry and Biochemistry,Miami University,Oxford,Ohio,USA
| |
Collapse
|
7
|
Lanzarotta A, Kelley CM. Forensic Analysis of Human Autopsy Tissue for the Presence of Polydimethylsiloxane (Silicone) and Volatile Cyclic Siloxanes using Macro FT-IR, FT-IR Spectroscopic Imaging and Headspace GC-MS. J Forensic Sci 2016; 61:867-874. [PMID: 27122436 DOI: 10.1111/1556-4029.13018] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2015] [Revised: 06/08/2015] [Accepted: 06/22/2015] [Indexed: 11/29/2022]
Abstract
This study describes effective and straightforward primary and secondary methods for the detection of silicone in human autopsy tissue. The primary method is polydimethylsiloxane (PDMS) specific and employs either macro-attenuated total reflection Fourier transform infrared (ATR-FT-IR) spectroscopy for samples with a high PDMS concentration (relative to that of the matrix) or micro-FT-IR spectroscopic imaging in a reflection/absorption modality for samples with a low PDMS concentration. Although the secondary method is not PDMS specific, it employs headspace gas chromatography with mass spectrometric detection (HS/GC-MS) for the detection of low molecular weight volatile cyclic siloxanes (VCS), which are characteristic marker compounds for PDMS. Overall, the combined results from the primary and secondary analyses provide reliable evidence for the presence of silicone.
Collapse
Affiliation(s)
- Adam Lanzarotta
- United States Food and Drug Administration, Forensic Chemistry Center, Cincinnati, OH, 45237
| | - Caroline Machal Kelley
- United States Food and Drug Administration, Forensic Chemistry Center, Cincinnati, OH, 45237
| |
Collapse
|
8
|
Analysis of Forensic Casework Utilizing Infrared Spectroscopic Imaging. SENSORS 2016; 16:278. [PMID: 26927101 PMCID: PMC4813853 DOI: 10.3390/s16030278] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/04/2015] [Revised: 01/22/2016] [Accepted: 02/02/2016] [Indexed: 12/16/2022]
Abstract
A search of the current scientific literature yields a limited number of studies that describe the use of Fourier transform infrared (FT-IR) spectroscopic imaging for the analysis of forensic casework, which is likely due to the fact that these instruments are fairly new commodities to the field of analytical chemistry and are therefore not yet commonplace in forensic laboratories. This report describes recent forensic case studies that have used the technique for determining the composition of a wide variety of multi-component sample types, including animal tissue sections for toxic inclusions, drugs/dietary supplements, an antibiotic with an active pharmaceutical ingredient (API) present as several different salt forms, an adulterated bulk API, unknown trace powders for illicit drugs and an ophthalmic solution suspected of being adulterated with bleach.
Collapse
|