1
|
Lu C, Rohilla P, Felner EI, Byagathvalli G, Azizoglu E, Bhamla MS, Prausnitz MR. Tolerability of a piezoelectric microneedle electroporator in human subjects. Bioeng Transl Med 2024; 9:e10662. [PMID: 39036075 PMCID: PMC11256137 DOI: 10.1002/btm2.10662] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2023] [Revised: 02/08/2024] [Accepted: 02/27/2024] [Indexed: 07/23/2024] Open
Abstract
Electroporation, or the use of electric pulses to facilitate the intracellular delivery of DNA, RNA, and other molecules, is a well-established technique, that has been demonstrated to significantly augment the immunogenicity of DNA/mRNA vaccines and therapeutics. However, the clinical translation of traditional electroporators has been limited due to high costs, large size, complex user operation, and poor tolerability in humans due to nerve stimulation. In prior work, we introduced ePatch: an ultra-low-cost, handheld, battery-free electroporator employing a piezoelectric pulser coupled with a microneedle electrode array that showed enhanced immunogenic responses to an intradermal SARS-CoV-2 DNA vaccine in mice. The current study shifts focus from efficacy to tolerability, hypothesizing that ePatch's microneedle array, which localizes the electric field to the superficial skin strata, will minimize nerve stimulation and improve patient comfort. We tested this hypothesis in 14 healthy adults, monitoring pain and other potential adverse effects associated with electroporation. Compared to the insertion of a traditional hypodermic needle, the ePatch was less painful. Adverse effects such as pain, tenderness, erythema and swelling at the application sites were minimal, transient, and statistically indistinguishable between the experimental and placebo ePatch application, suggesting excellent tolerability towards electroporation. In summary, ePatch has a favorable tolerability profile in humans and offers the potential for the safe use of electroporation in a variety of clinical settings, including DNA and mRNA vaccination.
Collapse
Affiliation(s)
- Chao‐Yi Lu
- Wallace H. Coulter Department of Biomedical Engineering at Georgia Tech and Emory University, Georgia Institute of TechnologyAtlantaGeorgiaUSA
| | - Pankaj Rohilla
- School of Chemical and Biomolecular Engineering, Georgia Institute of TechnologyAtlantaGeorgiaUSA
| | - Eric I. Felner
- School of Chemical and Biomolecular Engineering, Georgia Institute of TechnologyAtlantaGeorgiaUSA
- Department of Pediatrics, Division of EndocrinologyEmory University School of MedicineAtlantaGeorgiaUSA
| | - Gaurav Byagathvalli
- School of Chemical and Biomolecular Engineering, Georgia Institute of TechnologyAtlantaGeorgiaUSA
| | - Erkan Azizoglu
- School of Chemical and Biomolecular Engineering, Georgia Institute of TechnologyAtlantaGeorgiaUSA
| | - M. Saad Bhamla
- School of Chemical and Biomolecular Engineering, Georgia Institute of TechnologyAtlantaGeorgiaUSA
| | - Mark R. Prausnitz
- Wallace H. Coulter Department of Biomedical Engineering at Georgia Tech and Emory University, Georgia Institute of TechnologyAtlantaGeorgiaUSA
- School of Chemical and Biomolecular Engineering, Georgia Institute of TechnologyAtlantaGeorgiaUSA
| |
Collapse
|
2
|
Huang S, Henderson TR, Dojo Soeandy C, Lezhanska A, Henderson JT. An efficient low cost means of biophysical gene transfection in primary cells. Sci Rep 2024; 14:13179. [PMID: 38849388 PMCID: PMC11161637 DOI: 10.1038/s41598-024-62996-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Accepted: 05/23/2024] [Indexed: 06/09/2024] Open
Abstract
Efficient, facile gene modification of cells has become an indispensable part of modern molecular biology. For the majority of cell lines and several primary populations, such modifications can be readily performed through a variety of methods. However, many primary cell lines such as stem cells frequently suffer from poor transfection efficiency. Though several physical approaches have been introduced to circumvent these issues, they often require expensive/specialized equipment and/or consumables, utilize substantial cell numbers and often still suffer from poor efficiency. Viral methods are capable of transducing difficult cellular populations, however such methods can be time consuming for large arrays of gene targets, present biohazard concerns, and result in expression of viral proteins; issues of concern for certain experimental approaches. We report here a widely applicable, low-cost (< $100 CAD) method of electroporation, applicable to small (1-10 μl) cell volumes and composed of equipment readily available to the average investigator. Using this system we observe a sixfold increase in transfection efficiency in embryonic stem cell lines compared to commercial devices. Due to efficiency gains and reductions in volume and applied voltage, this process improves the survival of sensitive stem cell populations while reducing reagent requirements for protocols such as Cas9/gRNAs transfections.
Collapse
Affiliation(s)
- Shudi Huang
- Department of Pharmaceutical Sciences, University of Toronto, 144 College St. Rm 962, Toronto, ON, M5S 3M2, Canada
| | - Tyler R Henderson
- Department of Medical Genetics, Lunenfeld-Tanenbaum Research Institute, Mount Sinai Hospital, Toronto, ON, M5G 1X5, Canada
| | - Chesarahmia Dojo Soeandy
- Tumour Immunotherapy Program Cell Manufacturing Team, Princess Margaret Cancer Centre, University Health Network, 610 University Avenue, Rm 8-207, Toronto, ON, M5G 2M9, Canada
| | - Anastasiya Lezhanska
- Department of Medicine, Queen's University, 94 Stuart Street, Kingston, ON, K7L 3N6, Canada
| | - Jeffrey T Henderson
- Department of Pharmaceutical Sciences, University of Toronto, 144 College St. Rm 962, Toronto, ON, M5S 3M2, Canada.
| |
Collapse
|
3
|
Xuan Y, Wang C, Ghatak S, Sen CK. Tissue Nanotransfection Silicon Chip and Related Electroporation-Based Technologies for In Vivo Tissue Reprogramming. NANOMATERIALS (BASEL, SWITZERLAND) 2024; 14:217. [PMID: 38276735 PMCID: PMC10820803 DOI: 10.3390/nano14020217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2023] [Revised: 01/14/2024] [Accepted: 01/15/2024] [Indexed: 01/27/2024]
Abstract
Tissue nanotransfection (TNT), a cutting-edge technique of in vivo gene therapy, has gained substantial attention in various applications ranging from in vivo tissue reprogramming in regenerative medicine, and wound healing to cancer treatment. This technique harnesses the advancements in the semiconductor processes, facilitating the integration of conventional transdermal gene delivery methods-nanoelectroporation and microneedle technologies. TNT silicon chips have demonstrated considerable promise in reprogramming fibroblast cells of skin in vivo into vascular or neural cells in preclinical studies to assist in the recovery of injured limbs and damaged brain tissue. More recently, the application of TNT chips has been extended to the area of exosomes, which are vital for intracellular communication to track their functionality during the wound healing process. In this review, we provide an in-depth examination of the design, fabrication, and applications of TNT silicon chips, alongside a critical analysis of the electroporation-based gene transfer mechanisms. Additionally, the review discussed the existing limitations and challenges in the current technique, which may project future trajectories in the landscape of gene therapy. Through this exploration, the review aims to shed light on the prospects of TNT in the broader context of gene therapy and tissue regeneration.
Collapse
Affiliation(s)
| | | | | | - Chandan K. Sen
- McGowan Institute for Regenerative Medicine, Department of Surgery, University of Pittsburgh School of Medicine, Pittsburgh, PA 15219, USA
| |
Collapse
|
4
|
Kallmyer NE, Agarwal S, Eeg D, Khor R, Roby N, Vela Ramirez A, Hillier AC, Reuel NF. Lipid-Functionalized Single-Walled Carbon Nanotubes as Probes for Screening Cell Wall Disruptors. ACS APPLIED MATERIALS & INTERFACES 2023; 15:44621-44630. [PMID: 37721709 DOI: 10.1021/acsami.3c06592] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/19/2023]
Abstract
Membrane-active molecules are of great importance to drug delivery and antimicrobials applications. While the ability to prototype new membrane-active molecules has improved greatly with the advent of automated chemistries and rapid biomolecule expression techniques, testing methods are still limited by throughput, cost, and modularity. Existing methods suffer from feasibility constraints of working with pathogenic living cells and by intrinsic limitations of model systems. Herein, we demonstrate an abiotic sensor that uses semiconducting single-walled carbon nanotubes (SWCNTs) as near-infrared fluorescent transducers to report membrane interactions. This sensor is composed of SWCNTs aqueously suspended in lipid, creating a cylindrical, bilayer corona; these SWCNT probes are very sensitive to solvent access (changes in permittivity) and thus report morphological changes to the lipid corona by modulation of fluorescent signals, where binding and disruption are reported as brightening and attenuation, respectively. This mechanism is first demonstrated with chemical and physical membrane-disruptive agents, including ethanol and sodium dodecyl sulfate, and application of electrical pulses. Known cell-penetrating and antimicrobial peptides are then used to demonstrate how the dynamic response of these sensors can be deconvoluted to evaluate different parallel mechanisms of interaction. Last, SWCNTs functionalized in several different bacterial lipopolysaccharides (Pseudomonas aeruginosa, Klebsiella pneumoniae, and Escherichia coli) are used to evaluate a panel of known membrane-disrupting antimicrobials to demonstrate that drug selectivity can be assessed by suspension of SWCNTs with different membrane materials.
Collapse
Affiliation(s)
- Nathaniel E Kallmyer
- Department of Chemical and Biological Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Sparsh Agarwal
- Department of Chemical and Biological Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Danielle Eeg
- Department of Chemical and Biological Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Rachel Khor
- Department of Chemical and Biological Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Nathan Roby
- Department of Chemical and Biological Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Alma Vela Ramirez
- Department of Chemical and Biological Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Andrew C Hillier
- Department of Chemical and Biological Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Nigel F Reuel
- Department of Chemical and Biological Engineering, Iowa State University, Ames, Iowa 50011, United States
| |
Collapse
|
5
|
Modification of a Ready-Made High-Voltage Pulse Generator for Non-Thermal Irreversible Electroporation. Bull Exp Biol Med 2022; 173:276-280. [DOI: 10.1007/s10517-022-05533-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Indexed: 10/17/2022]
|
6
|
High Frequency Bipolar Electroporator with Double-Crowbar Circuit for Load-Independent Forming of Nanosecond Pulses. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12031370] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
In this work, a novel electroporation system (electroporator) is presented, which is capable of forming high frequency pulses in a broad range of parameters (65 ns–100 µs). The electroporator supports voltages up to 3 kV and currents up to 40 A and is based on H-bridge circuit topology. A synchronized double crowbar driving sequence is introduced to generate short nanosecond range pulses independently of the electroporator load. The resultant circuit generates pulses with repetition frequencies up to 5 MHz and supports unipolar, bipolar, and asymmetrical pulse sequences with arbitrary waveforms. The shortest pulse duration step is hardware limited to 33 ns. The electroporator was experimentally tested on the H69AR human lung cancer cell line using 20 kV/cm bipolar and unipolar 100 ns–1 μs pulses. Based on a YO-PRO-1 permeabilization assay, it was determined that the electroporator is suitable for applied research on electroporation. The system offers high flexibility in experimental design to trigger various electroporation-based phenomena.
Collapse
|
7
|
Mohd Asri MA, Nordin AN, Ramli N. Low-cost and cleanroom-free prototyping of microfluidic and electrochemical biosensors: Techniques in fabrication and bioconjugation. BIOMICROFLUIDICS 2021; 15:061502. [PMID: 34777677 PMCID: PMC8577868 DOI: 10.1063/5.0071176] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Accepted: 10/22/2021] [Indexed: 05/18/2023]
Abstract
Integrated microfluidic biosensors enable powerful microscale analyses in biology, physics, and chemistry. However, conventional methods for fabrication of biosensors are dependent on cleanroom-based approaches requiring facilities that are expensive and are limited in access. This is especially prohibitive toward researchers in low- and middle-income countries. In this topical review, we introduce a selection of state-of-the-art, low-cost prototyping approaches of microfluidics devices and miniature sensor electronics for the fabrication of sensor devices, with focus on electrochemical biosensors. Approaches explored include xurography, cleanroom-free soft lithography, paper analytical devices, screen-printing, inkjet printing, and direct ink writing. Also reviewed are selected surface modification strategies for bio-conjugates, as well as examples of applications of low-cost microfabrication in biosensors. We also highlight several factors for consideration when selecting microfabrication methods appropriate for a project. Finally, we share our outlook on the impact of these low-cost prototyping strategies on research and development. Our goal for this review is to provide a starting point for researchers seeking to explore microfluidics and biosensors with lower entry barriers and smaller starting investment, especially ones from low resource settings.
Collapse
Affiliation(s)
- Mohd Afiq Mohd Asri
- Department of Electrical and Computer Engineering, Kulliyyah of Engineering, International Islamic University Malaysia, 53100 Gombak, Selangor, Malaysia
| | - Anis Nurashikin Nordin
- Department of Electrical and Computer Engineering, Kulliyyah of Engineering, International Islamic University Malaysia, 53100 Gombak, Selangor, Malaysia
- Author to whom correspondence should be addressed:
| | - Nabilah Ramli
- Department of Mechanical Engineering, Kulliyyah of Engineering, International Islamic University Malaysia, 53100 Gombak, Selangor, Malaysia
| |
Collapse
|
8
|
Abstract
More than 60 years ago, Richard Feynman gave a lecture titled "There's Plenty of Room at the Bottom: An Invitation to Enter a New Field of Physics", where he called on others to join the then-nascent field of nanotechnology. In a similar spirit, we wish to invite chemists, biologists, physicists, bioengineers, educators, high school students, and inventors of all backgrounds to join us in the emerging field of frugal science. In this Review, we define frugal science and use six case studies to describe the broad applications of frugal science, from synthetic biology to disease diagnostics. We conclude by establishing an argument for curiosity-driven research through frugal science to enable broader access in chemical and bioengineering research and drive innovation.
Collapse
Affiliation(s)
- Gaurav Byagathvalli
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - Elio J Challita
- Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30311, United States
| | - M Saad Bhamla
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| |
Collapse
|
9
|
An ultra-low-cost electroporator with microneedle electrodes (ePatch) for SARS-CoV-2 vaccination. Proc Natl Acad Sci U S A 2021; 118:2110817118. [PMID: 34670842 PMCID: PMC8609327 DOI: 10.1073/pnas.2110817118] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/13/2021] [Indexed: 12/30/2022] Open
Abstract
Low-cost and rapidly distributable vaccines are urgently needed to combat COVID-19 and future pandemics, especially for developing countries and other low-resource settings. DNA vaccines are inexpensive, rapidly developed, and safe, but require bulky and expensive electroporation devices for effective vaccination, which presents challenges to affordable and mass vaccination. We developed an ultra-low-cost (<1 USD), handheld (<50 g), battery-free electroporation system combining a thumb-actuated piezoelectric pulser and a microneedle electrode array skin interface for DNA vaccination against COVID-19, which was shown to be immunogenic and well-tolerated in animal studies. This study provides a proof-of-concept that DNA vaccination against epidemics can be achieved using an ultra-low-cost electroporator that is inexpensive enough for single use and robust enough for repeated use if desired. Vaccination against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and other pathogens with pandemic potential requires safe, protective, inexpensive, and easily accessible vaccines that can be developed and manufactured rapidly at a large scale. DNA vaccines can achieve these criteria, but induction of strong immune responses has often required bulky, expensive electroporation devices. Here, we report an ultra-low-cost (<1 USD), handheld (<50 g) electroporation system utilizing a microneedle electrode array (“ePatch”) for DNA vaccination against SARS-CoV-2. The low cost and small size are achieved by combining a thumb-operated piezoelectric pulser derived from a common household stove lighter that emits microsecond, bipolar, oscillatory electric pulses and a microneedle electrode array that targets delivery of high electric field strength pulses to the skin’s epidermis. Antibody responses against SARS-CoV-2 induced by this electroporation system in mice were strong and enabled at least 10-fold dose sparing compared to conventional intramuscular or intradermal injection of the DNA vaccine. Vaccination was well tolerated with mild, transient effects on the skin. This ePatch system is easily portable, without any battery or other power source supply, offering an attractive, inexpensive approach for rapid and accessible DNA vaccination to combat COVID-19, as well as other epidemics.
Collapse
|
10
|
Knapp BD, Zhu L, Huang KC. SiCTeC: An inexpensive, easily assembled Peltier device for rapid temperature shifting during single-cell imaging. PLoS Biol 2020; 18:e3000786. [PMID: 33156840 PMCID: PMC7685484 DOI: 10.1371/journal.pbio.3000786] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 11/24/2020] [Accepted: 09/08/2020] [Indexed: 12/12/2022] Open
Abstract
Single-cell imaging, combined with recent advances in image analysis and microfluidic technologies, have enabled fundamental discoveries of cellular responses to chemical perturbations that are often obscured by traditional liquid-culture experiments. Temperature is an environmental variable well known to impact growth and to elicit specific stress responses at extreme values; it is often used as a genetic tool to interrogate essential genes. However, the dynamic effects of temperature shifts have remained mostly unstudied at the single-cell level, due largely to engineering challenges related to sample stability, heatsink considerations, and temperature measurement and feedback. Additionally, the few commercially available temperature-control platforms are costly. Here, we report an inexpensive (<$110) and modular Single-Cell Temperature Controller (SiCTeC) device for microbial imaging-based on straightforward modifications of the typical slide-sample-coverslip approach to microbial imaging-that controls temperature using a ring-shaped Peltier module and microcontroller feedback. Through stable and precise (±0.15°C) temperature control, SiCTeC achieves reproducible and fast (1-2 min) temperature transitions with programmable waveforms between room temperature and 45°C with an air objective. At the device's maximum temperature of 89°C, SiCTeC revealed that Escherichia coli cells progressively shrink and lose cellular contents. During oscillations between 30°C and 37°C, cells rapidly adapted their response to temperature upshifts. Furthermore, SiCTeC enabled the discovery of rapid morphological changes and enhanced sensitivity to substrate stiffness during upshifts to nonpermissive temperatures in temperature-sensitive mutants of cell-wall synthesis enzymes. Overall, the simplicity and affordability of SiCTeC empowers future studies of the temperature dependence of single-cell physiology.
Collapse
Affiliation(s)
- Benjamin D. Knapp
- Biophysics Program, Stanford University, Stanford, California, United States of America
| | - Lillian Zhu
- Department of Bioengineering, Stanford University, Stanford, California, United States of America
| | - Kerwyn Casey Huang
- Biophysics Program, Stanford University, Stanford, California, United States of America
- Department of Bioengineering, Stanford University, Stanford, California, United States of America
- Department of Microbiology and Immunology, Stanford University School of Medicine, Stanford, California, United States of America
- Chan Zuckerberg Biohub, San Francisco, California, United States of America
| |
Collapse
|