1
|
Gu X, Hou Q, Liu J, Xia P, Duan Q, Zhu G. Sef fimbria operon construction, expression, and function for direct rapid detection of Salmonella Enteritidis. Appl Microbiol Biotechnol 2021; 105:5631-5641. [PMID: 34155530 DOI: 10.1007/s00253-021-11400-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 05/27/2021] [Accepted: 05/29/2021] [Indexed: 11/28/2022]
Abstract
Salmonella Enteritidis (SE) causes both horizontal and vertical transmission of diseases in poultry industry and is also one of the main causes of human food poisoning. Sequence analysis of the sef operon of poultry-derived Salmonella serotypes showed the presence of an entire sef operon in SE, whereas only sef pseudogenes were found in Salmonella Gallinarum and Salmonella Pullorum. Subsequently, the sef operon of SE was cloned into the pBR322 plasmid and expressed in a modified Escherichia coli strain SE5000. sef operon expression was demonstrated using sodium dodecyl sulfate-polyacrylamide gel electrophoresis, western blot, agglutination assay, and transmission electron microscopy. The results showed that SE5000+Sef, but not SE5000+pBR322, could specifically react with SE-positive chicken serum in an agglutination assay, which could be clearly visualized by the naked eye within less than 2 min. In contrast, SE5000+Sef could not be recognized in Salmonella Gallinarum- and Salmonella Pullorum-positive chicken sera. Next, taking advantage of the exclusive presence of an entire sef operon in SE, we set up an agglutination-based detection system to monitor the dynamics of Sef-targeted antibody from SE-infected chicks for 47 days. Using the proposed detection method, SE was readily detectable starting from 2 weeks post-infection. Finally, we compared the proposed SE5000+Sef-based detection system with commercially available agglutination antigen using the classical bacterial isolation and identification procedure as reference. The results showed that the SE5000+Sef system was more consistent with the results of bacterial isolation and identification with almost 100% accuracy. We established a simple, sensitive, and cheap agglutination method for rapid and specific detection of SE-infected chickens, which can facilitate epidemiological investigation and eradication of SE infections. KEY POINTS: • Only the Salmonella Enteritidis serotype expressed Sef fimbriae in chicken infected with SE. • A rapid, large-scale method of detection by the naked eye of detection of SE-infected chicken is presented.
Collapse
Affiliation(s)
- Xuanqiang Gu
- College of Veterinary Medicine, Yangzhou University, 12 East Wenhui Road, Yangzhou, 225009, China.,Jiangsu Co-Innovation Center for Important Animal Infectious Diseases and Zoonoses, Yangzhou, 225009, China.,Joint International Research Laboratory of Agriculture and Agri-Product Safety of Ministry of Education of China, Yangzhou University, Yangzhou, 225009, China
| | - Qianxi Hou
- College of Veterinary Medicine, Yangzhou University, 12 East Wenhui Road, Yangzhou, 225009, China.,Jiangsu Co-Innovation Center for Important Animal Infectious Diseases and Zoonoses, Yangzhou, 225009, China.,Joint International Research Laboratory of Agriculture and Agri-Product Safety of Ministry of Education of China, Yangzhou University, Yangzhou, 225009, China
| | - Jiaqi Liu
- College of Veterinary Medicine, Yangzhou University, 12 East Wenhui Road, Yangzhou, 225009, China.,Jiangsu Co-Innovation Center for Important Animal Infectious Diseases and Zoonoses, Yangzhou, 225009, China.,Joint International Research Laboratory of Agriculture and Agri-Product Safety of Ministry of Education of China, Yangzhou University, Yangzhou, 225009, China
| | - Pengpeng Xia
- College of Veterinary Medicine, Yangzhou University, 12 East Wenhui Road, Yangzhou, 225009, China.,Jiangsu Co-Innovation Center for Important Animal Infectious Diseases and Zoonoses, Yangzhou, 225009, China.,Joint International Research Laboratory of Agriculture and Agri-Product Safety of Ministry of Education of China, Yangzhou University, Yangzhou, 225009, China
| | - Qiangde Duan
- College of Veterinary Medicine, Yangzhou University, 12 East Wenhui Road, Yangzhou, 225009, China. .,Jiangsu Co-Innovation Center for Important Animal Infectious Diseases and Zoonoses, Yangzhou, 225009, China. .,Joint International Research Laboratory of Agriculture and Agri-Product Safety of Ministry of Education of China, Yangzhou University, Yangzhou, 225009, China.
| | - Guoqiang Zhu
- College of Veterinary Medicine, Yangzhou University, 12 East Wenhui Road, Yangzhou, 225009, China. .,Jiangsu Co-Innovation Center for Important Animal Infectious Diseases and Zoonoses, Yangzhou, 225009, China. .,Joint International Research Laboratory of Agriculture and Agri-Product Safety of Ministry of Education of China, Yangzhou University, Yangzhou, 225009, China.
| |
Collapse
|
2
|
Law ECY, Leung DTM, Tam FCH, Cheung KKT, Cheng NHY, Lim PL. IgM Antibodies Can Access Cryptic Antigens Denied to IgG: Hypothesis on Novel Binding Mechanism. Front Immunol 2019; 10:1820. [PMID: 31428101 PMCID: PMC6688401 DOI: 10.3389/fimmu.2019.01820] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2019] [Accepted: 07/18/2019] [Indexed: 11/13/2022] Open
Abstract
Antibodies are well-known protein mediators of immunity. IgM is the primordial member and the neglected sibling of the later-evolved and more proficient IgG in regard to their therapeutic and diagnostic use. Serendipitously, however, we found a paradox: While murine IgM antibodies specific for guanosine triphosphate (GTP) were able to recognize native guanylyl antigens found in primate or rat muscle tissues by immunofluorescence assays (which mimicked the auto-antibodies from autoimmune patients to skeletal or smooth muscle), the murine and human IgG counterparts failed. The results were replicated in cell-free direct binding assays using small latex microspheres decorated densely with GTP. The IgG antibodies could bind, however, if GTP was presented more spaciously on larger particles or as a univalent hapten. Accordingly, oligomerization of GTP (30-mer) destroyed the binding of the IgG antibodies but enhanced that of the IgMs in inhibition ELISA. We reason that, contrary to current belief, IgM does not bind in a lock-and-key manner like IgG. We hypothesize that whereas the intact and rigid antigen-binding site of IgG hinders the antibody from docking with antigens that are obstructed, in IgM, the two component polypeptides of the antigen-binding site can dissociate from each other and navigate individually through obstacles like the ancestral single-polypeptide antibodies found in sharks and camelids, both components eventually re-grouping around the antigen. We further speculate that polyreactive IgMs, which enigmatically bind to more than one type of antigen, use the same modus operandi. These findings call for a re-look at the clinical potential of IgM antibodies particularly in specific areas of cancer therapy, tissue pathology and vaccine design, where IgG antibodies have failed due to target inaccessibility.
Collapse
Affiliation(s)
- Eric Chun Yiu Law
- Clinical Immunology Unit, The Chinese University of Hong Kong, Hong Kong, China
| | | | - Frankie Chi Hang Tam
- Clinical Immunology Unit, The Chinese University of Hong Kong, Hong Kong, China.,IgGENE, FoTan, Hong Kong, China
| | | | - Naomi Hua Yin Cheng
- Clinical Immunology Unit, The Chinese University of Hong Kong, Hong Kong, China
| | - Pak Leong Lim
- Clinical Immunology Unit, The Chinese University of Hong Kong, Hong Kong, China.,IgGENE, FoTan, Hong Kong, China
| |
Collapse
|
3
|
Abstract
BACKGROUND Differentiating both typhoid (Salmonella Typhi) and paratyphoid (Salmonella Paratyphi A) infection from other causes of fever in endemic areas is a diagnostic challenge. Although commercial point-of-care rapid diagnostic tests (RDTs) for enteric fever are available as alternatives to the current reference standard test of blood or bone marrow culture, or to the widely used Widal Test, their diagnostic accuracy is unclear. If accurate, they could potentially replace blood culture as the World Health Organization (WHO)-recommended main diagnostic test for enteric fever. OBJECTIVES To assess the diagnostic accuracy of commercially available rapid diagnostic tests (RDTs) and prototypes for detecting Salmonella Typhi or Paratyphi A infection in symptomatic persons living in endemic areas. SEARCH METHODS We searched the Cochrane Infectious Diseases Group Specialized Register, MEDLINE, Embase, Science Citation Index, IndMED, African Index Medicus, LILACS, ClinicalTrials.gov, and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) up to 4 March 2016. We manually searched WHO reports, and papers from international conferences on Salmonella infections. We also contacted test manufacturers to identify studies. SELECTION CRITERIA We included diagnostic accuracy studies of enteric fever RDTs in patients with fever or with symptoms suggestive of enteric fever living in endemic areas. We classified the reference standard used as either Grade 1 (result from a blood culture and a bone marrow culture) or Grade 2 (result from blood culture and blood polymerase chain reaction, or from blood culture alone). DATA COLLECTION AND ANALYSIS Two review authors independently extracted the test result data. We used a modified QUADAS-2 extraction form to assess methodological quality. We performed a meta-analysis when there were sufficient studies for the test and heterogeneity was reasonable. MAIN RESULTS Thirty-seven studies met the inclusion criteria and included a total of 5080 participants (range 50 to 1732). Enteric fever prevalence rates in the study populations ranged from 1% to 75% (median prevalence 24%, interquartile range (IQR) 11% to 46%). The included studies evaluated 16 different RDTs, and 16 studies compared two or more different RDTs. Only three studies used the Grade 1 reference standard, and only 11 studies recruited unselected febrile patients. Most included studies were from Asia, with five studies from sub-Saharan Africa. All of the RDTs were designed to detect S.Typhi infection only.Most studies evaluated three RDTs and their variants: TUBEX in 14 studies; Typhidot (Typhidot, Typhidot-M, and TyphiRapid-Tr02) in 22 studies; and the Test-It Typhoid immunochromatographic lateral flow assay, and its earlier prototypes (dipstick, latex agglutination) developed by the Royal Tropical Institute, Amsterdam (KIT) in nine studies. Meta-analyses showed an average sensitivity of 78% (95% confidence interval (CI) 71% to 85%) and specificity of 87% (95% CI 82% to 91%) for TUBEX; and an average sensitivity of 69% (95% CI 59% to 78%) and specificity of 90% (95% CI 78% to 93%) for all Test-It Typhoid and prototype tests (KIT). Across all forms of the Typhidot test, the average sensitivity was 84% (95% CI 73% to 91%) and specificity was 79% (95% CI 70% to 87%). When we based the analysis on the 13 studies of the Typhidot test that either reported indeterminate test results or where the test format means there are no indeterminate results, the average sensitivity was 78% (95% CI 65% to 87%) and specificity was 77% (95% CI 66% to 86%). We did not identify any difference in either sensitivity or specificity between TUBEX, Typhidot, and Test-it Typhoid tests when based on comparison to the 13 Typhidot studies where indeterminate results are either reported or not applicable. If TUBEX and Test-it Typhoid are compared to all Typhidot studies, the sensitivity of Typhidot was higher than Test-it Typhoid (15% (95% CI 2% to 28%), but other comparisons did not show a difference at the 95% level of CIs.In a hypothetical cohort of 1000 patients presenting with fever where 30% (300 patients) have enteric fever, on average Typhidot tests reporting indeterminate results or where tests do not produce indeterminate results will miss the diagnosis in 66 patients with enteric fever, TUBEX will miss 66, and Test-It Typhoid and prototype (KIT) tests will miss 93. In the 700 people without enteric fever, the number of people incorrectly diagnosed with enteric fever would be 161 with Typhidot tests, 91 with TUBEX, and 70 with Test-It Typhoid and prototype (KIT) tests. The CIs around these estimates were wide, with no difference in false positive results shown between tests.The quality of the data for each study was evaluated using a standardized checklist called QUADAS-2. Overall, the certainty of the evidence in the studies that evaluated enteric fever RDTs was low. AUTHORS' CONCLUSIONS In 37 studies that evaluated the diagnostic accuracy of RDTs for enteric fever, few studies were at a low risk of bias. The three main RDT tests and variants had moderate diagnostic accuracy. There was no evidence of a difference between the average sensitivity and specificity of the three main RDT tests. More robust evaluations of alternative RDTs for enteric fever are needed.
Collapse
Affiliation(s)
- Lalith Wijedoru
- Liverpool School of Tropical MedicineDepartment of Clinical SciencesLiverpoolUKL3 5QA
| | - Sue Mallett
- University of BirminghamInstitute of Applied Health SciencesEdgbastonBirminghamUKB15 2TT
| | - Christopher M Parry
- Liverpool School of Tropical MedicineDepartment of Clinical SciencesLiverpoolUKL3 5QA
| | | |
Collapse
|
4
|
Osteopontin Fragments with Intact Thrombin-Sensitive Site Circulate in Cervical Cancer Patients. PLoS One 2016; 11:e0160412. [PMID: 27494141 PMCID: PMC4975440 DOI: 10.1371/journal.pone.0160412] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2016] [Accepted: 07/19/2016] [Indexed: 01/02/2023] Open
Abstract
We investigated whether circulating osteopontin (OPN) could be used as a biomarker for cervical cancer. We employed a monoclonal antibody (mAb 659) specific for the unique and intact thrombin-sensitive site in OPN using an inhibition ELISA. We found significantly higher levels of OPN in 33 cervical cancer patients in both the plasma (mean +/- SD, 612 +/- 106 ng/mL) and serum (424 +/- 121 ng/mL) compared to healthy subjects [409 +/- 56 ng/mL, from 31 plasma samples (P < 0.0001), and 314 +/- 98 ng/mL, from 32 serum samples (P = 0.0002), respectively]. Similar results were obtained when the plasma from a bigger group (147 individuals) of cervical cancer patients (560 +/- 211 ng/mL) were compared with the same plasma samples of the healthy individuals (P = 0.0014). More significantly, the OPN level was highest in stage III-IV disease (614 +/- 210 ng/mL, from 52 individuals; P = 0.0001) and least and non-discriminatory in stage I (473 +/- 110 ng/mL, from 40 individuals; P = 0.5318). No such discrimination was found when a mAb of a different specificity (mAb 446) was used in a similar inhibition ELISA to compare the two groups in the first study; a commercial capture ELISA also failed. The possibility that the target epitope recognized by the antibody probe in these assays was absent from the circulating OPN due to protein truncation was supported by gel fractionation of the OPN found in patients' plasma: 60-64 kDa fragments were found instead of the presumably full-length OPN (68 kDa) seen in healthy people. How these fragments are generated and what possible role they play in cancer biology remain interesting questions.
Collapse
|
5
|
Storey HL, Huang Y, Crudder C, Golden A, de los Santos T, Hawkins K. A Meta-Analysis of Typhoid Diagnostic Accuracy Studies: A Recommendation to Adopt a Standardized Composite Reference. PLoS One 2015; 10:e0142364. [PMID: 26566275 PMCID: PMC4643909 DOI: 10.1371/journal.pone.0142364] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2015] [Accepted: 10/21/2015] [Indexed: 01/09/2023] Open
Abstract
Novel typhoid diagnostics currently under development have the potential to improve clinical care, surveillance, and the disease burden estimates that support vaccine introduction. Blood culture is most often used as the reference method to evaluate the accuracy of new typhoid tests; however, it is recognized to be an imperfect gold standard. If no single gold standard test exists, use of a composite reference standard (CRS) can improve estimation of diagnostic accuracy. Numerous studies have used a CRS to evaluate new typhoid diagnostics; however, there is no consensus on an appropriate CRS. In order to evaluate existing tests for use as a reference test or inclusion in a CRS, we performed a systematic review of the typhoid literature to include all index/reference test combinations observed. We described the landscape of comparisons performed, showed results of a meta-analysis on the accuracy of the more common combinations, and evaluated sources of variability based on study quality. This wide-ranging meta-analysis suggests that no single test has sufficiently good performance but some existing diagnostics may be useful as part of a CRS. Additionally, based on findings from the meta-analysis and a constructed numerical example demonstrating the use of CRS, we proposed necessary criteria and potential components of a typhoid CRS to guide future recommendations. Agreement and adoption by all investigators of a standardized CRS is requisite, and would improve comparison of new diagnostics across independent studies, leading to the identification of a better reference test and improved confidence in prevalence estimates.
Collapse
Affiliation(s)
- Helen L. Storey
- Diagnostics Program, PATH, Seattle, Washington, United States of America
- * E-mail:
| | - Ying Huang
- Fred Hutchinson Cancer Research Center, Seattle, Washington, United States of America
| | - Chris Crudder
- Diagnostics Program, PATH, Seattle, Washington, United States of America
| | - Allison Golden
- Diagnostics Program, PATH, Seattle, Washington, United States of America
| | - Tala de los Santos
- Diagnostics Program, PATH, Seattle, Washington, United States of America
| | - Kenneth Hawkins
- Diagnostics Program, PATH, Seattle, Washington, United States of America
| |
Collapse
|
6
|
Nugraha J, Marpaung FR, Tam FCH, Lim PL. Microbiological culture simplified using anti-O12 monoclonal antibody in TUBEX test to detect Salmonella bacteria from blood culture broths of enteric fever patients. PLoS One 2012; 7:e49586. [PMID: 23166719 PMCID: PMC3500315 DOI: 10.1371/journal.pone.0049586] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2012] [Accepted: 10/15/2012] [Indexed: 12/02/2022] Open
Abstract
Definitive diagnosis of infectious diseases, including food poisoning, requires culture and identification of the infectious agent. We described how antibodies could be used to shorten this cumbersome process. Specifically, we employed an anti-Salmonella lipopolysaccharide O12 monoclonal antibody in an epitope-inhibition 10-min test (TUBEX TP) to detect O12+Salmonella organisms directly from routine blood culture broths. The aim is to obviate the need to subculture the broth and subsequently identify the colonies. Thus, blood from 78 young outpatients suspected of having enteric fever was incubated in an enrichment broth, and after 2 or 4 days, broth samplings were examined by TUBEX TP as well as by conventional agar culture and identification. TUBEX TP was performed before the culture results. Eighteen isolates of S. Typhi (15 after 2 days) and 10 isolates of S. Paratyphi A (4 after 2 days) were obtained by conventional culture. Both these Salmonella serotypes, the main causes of enteric fever, share the O12 antigen. In all instances where either of these organisms was present (cultured), TUBEX TP was positive (score 4 [light blue] – to – score 10 [dark blue]; negative is 0 [pink-colored]) i.e. 100% sensitive. Identification of the specific Salmonella serotype in TUBEX-positive cases was achieved subsequently by conventional slide agglutination using appropriate polyclonal antisera against the various serotypes. Twelve Escherichia coli, 1 Alcaligenes spp. and 1 Enterobacter spp. were isolated. All of these cases, including all the 36 culture-negative broths, were TUBEX-negative i.e. TUBEX TP was 100% specific. In a separate study using known laboratory strains, TUBEX TF, which detects S. Typhi but not S. Paratyphi A via the O9 antigen, was found to efficiently complement TUBEX TP as a differential test. Thus, TUBEX TP and TUBEX TF are useful adjuncts to conventional culture because they can save considerable time (>2 days), costs and manpower.
Collapse
Affiliation(s)
- Jusak Nugraha
- Department of Clinical Pathology, Faculty of Medicine, Airlangga University/Dr. Soetomo Hospital, Surabaya, Indonesia
- Tropical Disease Center, Airlangga University, Surabaya, Indonesia
| | - Ferdy R. Marpaung
- Department of Clinical Pathology, Faculty of Medicine, Airlangga University/Dr. Soetomo Hospital, Surabaya, Indonesia
| | | | | |
Collapse
|
7
|
Gopinath S, Carden S, Monack D. Shedding light on Salmonella carriers. Trends Microbiol 2012; 20:320-7. [DOI: 10.1016/j.tim.2012.04.004] [Citation(s) in RCA: 100] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2012] [Revised: 04/03/2012] [Accepted: 04/10/2012] [Indexed: 01/10/2023]
|
8
|
Shakoor S, Zaidi AK, Hasan R. Tropical Bacterial Gastrointestinal Infections. Infect Dis Clin North Am 2012; 26:437-53. [DOI: 10.1016/j.idc.2012.02.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|