1
|
A coupled atrioventricular-aortic setup for in-vitro hemodynamic study of the systemic circulation: Design, fabrication, and physiological relevancy. PLoS One 2022; 17:e0267765. [PMID: 36331977 PMCID: PMC9635706 DOI: 10.1371/journal.pone.0267765] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Accepted: 10/13/2022] [Indexed: 11/06/2022] Open
Abstract
In-vitro models of the systemic circulation have gained a lot of interest for fundamental understanding of cardiovascular dynamics and for applied hemodynamic research. In this study, we introduce a physiologically accurate in-vitro hydraulic setup that models the hemodynamics of the coupled atrioventricular-aortic system. This unique experimental simulator has three major components: 1) an arterial system consisting of a human-scale artificial aorta along with the main branches, 2) an artificial left ventricle (LV) sac connected to a programmable piston-in-cylinder pump for simulating cardiac contraction and relaxation, and 3) an artificial left atrium (LA). The setup is designed in such a way that the basal LV is directly connected to the aortic root via an aortic valve, and to the LA via an artificial mitral valve. As a result, two-way hemodynamic couplings can be achieved for studying the effects that the LV, aorta, and LA have on each other. The collected pressure and flow measurements from this setup demonstrate a remarkable correspondence to clinical hemodynamics. We also investigate the physiological relevancies of isolated effects on cardiovascular hemodynamics of various major global parameters found in the circulatory system, including LV contractility, LV preload, heart rate, aortic compliance, and peripheral resistance. Subsequent control over such parameters ultimately captures physiological hemodynamic effects of LV systolic dysfunction, preload (cardiac) diseases, and afterload (arterial) diseases. The detailed design and fabrication of the proposed setup is also provided.
Collapse
|
2
|
Proof-of-concept for a non-invasive, portable, and wireless device for cardiovascular monitoring in pediatric patients. PLoS One 2020; 15:e0227145. [PMID: 31899768 PMCID: PMC6941801 DOI: 10.1371/journal.pone.0227145] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2019] [Accepted: 12/11/2019] [Indexed: 11/19/2022] Open
Abstract
Measurement of cardiac function is vital for the health of pediatric patients with heart disease. Standard tools to measure function including echocardiogram and magnetic residence imaging are time intensive, costly, and have limited accessibility. The Vivio is a novel, non-invasive, handheld device that screens for cardiac dysfunction by analyzing intrinsic frequencies (IF) ω1 and ω2 of carotid artery waveforms. Prior studies demonstrated that left ventricular ejection fraction can be derived from IFs in adults. This study 1) studies whether the Vivio can capture carotid arterial pulse waveform data in children ages 0–19 years old; 2) tests the performance of two sensor head geometries, one larger and smaller than the standard size used in adults, designed for the pediatric population; 3) compares the IFs between pediatric age groups and adults with normal function. The Vivio successfully measured a carotid artery waveform in all children over 5 years old and 28% of children under the age of five. The small head did not accurately measure a waveform in any age group. One-way analysis of variance (ANOVA) demonstrated a difference in the IF ω1 between the adult and pediatric cohorts (F = 7.3, Prob>F = 0.0001). Post host analysis demonstrated a difference between the adult cohort (ω1 = 99 +/- 5 bpm) and the cohorts ages 0–4 (ω1 = 111 +/- 2 bpm; p = 0.0006) and 15–19 years old (ω1 = 105 +/-5 bpm; p = 0.02). One-way ANOVA demonstrated a difference in the IF ω2 between the adult and pediatric cohorts (F = 4.8, Prob>F = 0.003), specifically between the adult (ω2 = 81 +/- 13 bpm) and age 0–4 cohorts (ω2 = 48 +/- 8 bpm; p = 0.002). These results suggest that the Vivio can be used to capture carotid pulse waveform data in pediatric populations and that the data produced can be used to measure intrinsic frequencies.
Collapse
|
4
|
Yigit B, Pekkan K. Non-dimensional physics of pulsatile cardiovascular networks and energy efficiency. J R Soc Interface 2016; 13:20151019. [PMID: 26819334 PMCID: PMC4759807 DOI: 10.1098/rsif.2015.1019] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2015] [Accepted: 01/04/2016] [Indexed: 11/12/2022] Open
Abstract
In Nature, there exist a variety of cardiovascular circulation networks in which the energetic ventricular load has both steady and pulsatile components. Steady load is related to the mean cardiac output (CO) and the haemodynamic resistance of the peripheral vascular system. On the other hand, the pulsatile load is determined by the simultaneous pressure and flow waveforms at the ventricular outlet, which in turn are governed through arterial wave dynamics (transmission) and pulse decay characteristics (windkessel effect). Both the steady and pulsatile contributions of the haemodynamic power load are critical for characterizing/comparing disease states and for predicting the performance of cardiovascular devices. However, haemodynamic performance parameters vary significantly from subject to subject because of body size, heart rate and subject-specific CO. Therefore, a 'normalized' energy dissipation index, as a function of the 'non-dimensional' physical parameters that govern the circulation networks, is needed for comparative/integrative biological studies and clinical decision-making. In this paper, a complete network-independent non-dimensional formulation that incorporates pulsatile flow regimes is developed. Mechanical design variables of cardiovascular flow systems are identified and the Buckingham Pi theorem is formally applied to obtain the corresponding non-dimensional scaling parameter sets. Two scaling approaches are considered to address both the lumped parameter networks and the distributed circulation components. The validity of these non-dimensional number sets is tested extensively through the existing empirical allometric scaling laws of circulation systems. Additional validation studies are performed using a parametric numerical arterial model that represents the transmission and windkessel characteristics, which are adjusted to represent different body sizes and non-dimensional haemodynamic states. Simulations demonstrate that the proposed non-dimensional indices are independent of body size for healthy conditions, but are sensitive to deviations caused by off-design disease states that alter the energetic load. Sensitivity simulations are used to identify the relationship between pulsatile power loss and non-dimensional characteristics, and optimal operational states are computed.
Collapse
Affiliation(s)
- Berk Yigit
- Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA, USA
| | - Kerem Pekkan
- Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, USA Department of Mechanical Engineering, Koç University, Istanbul, Turkey
| |
Collapse
|
5
|
Pahlevan NM, Tavallali P, Rinderknecht DG, Petrasek D, Matthews RV, Hou TY, Gharib M. Intrinsic frequency for a systems approach to haemodynamic waveform analysis with clinical applications. J R Soc Interface 2015; 11:20140617. [PMID: 25008087 DOI: 10.1098/rsif.2014.0617] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
The reductionist approach has dominated the fields of biology and medicine for nearly a century. Here, we present a systems science approach to the analysis of physiological waveforms in the context of a specific case, cardiovascular physiology. Our goal in this study is to introduce a methodology that allows for novel insight into cardiovascular physiology and to show proof of concept for a new index for the evaluation of the cardiovascular system through pressure wave analysis. This methodology uses a modified version of sparse time-frequency representation (STFR) to extract two dominant frequencies we refer to as intrinsic frequencies (IFs; ω1 and ω2). The IFs are the dominant frequencies of the instantaneous frequency of the coupled heart + aorta system before the closure of the aortic valve and the decoupled aorta after valve closure. In this study, we extract the IFs from a series of aortic pressure waves obtained from both clinical data and a computational model. Our results demonstrate that at the heart rate at which the left ventricular pulsatile workload is minimized the two IFs are equal (ω1 = ω2). Extracted IFs from clinical data indicate that at young ages the total frequency variation (Δω = ω1 - ω2) is close to zero and that Δω increases with age or disease (e.g. heart failure and hypertension). While the focus of this paper is the cardiovascular system, this approach can easily be extended to other physiological systems or any biological signal.
Collapse
Affiliation(s)
- Niema M Pahlevan
- Medical Engineering, Division of Engineering and Applied Sciences, California Institute of Technology, 1200 East California Boulevard, MC 301-46, Pasadena, CA 91125, USA
| | - Peyman Tavallali
- Applied and Computational Mathematics, Division of Engineering and Applied Sciences, California Institute of Technology, 1200 East California Boulevard, MC 9-94, Pasadena, CA 91125, USA
| | - Derek G Rinderknecht
- Graduate Aerospace Laboratories, Division of Engineering and Applied Sciences, California Institute of Technology, 1200 East California Boulevard, MC 205-45, Pasadena, CA 91125, USA
| | - Danny Petrasek
- Medical Engineering, Division of Engineering and Applied Sciences, California Institute of Technology, 1200 East California Boulevard, MC 217-50, Pasadena, CA 91125, USA
| | - Ray V Matthews
- Keck School of Medicine, University of Southern California, 1510 San Pablo Street, Suite 322, Los Angeles, CA 90033, USA
| | - Thomas Y Hou
- Applied and Computational Mathematics, Division of Engineering and Applied Sciences, California Institute of Technology, 1200 East California Boulevard, MC 9-94, Pasadena, CA 91125, USA
| | - Morteza Gharib
- Graduate Aerospace Laboratories, Division of Engineering and Applied Sciences, California Institute of Technology, 1200 East California Boulevard, MC 205-45, Pasadena, CA 91125, USA
| |
Collapse
|