Yao K, Wang M, Du Y, Liu J, Wang Q, Wang R, Wu H, Yue H. Efficient EPID-based quality assurance of beam time delay for respiratory-gated radiotherapy with validation on Catalyst™ and AlignRT™ systems. J Appl Clin Med Phys 2024; 25:e14376. [PMID: 38695849 PMCID: PMC11302812 DOI: 10.1002/acm2.14376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 04/11/2024] [Accepted: 04/16/2024] [Indexed: 08/09/2024] Open
Abstract
PURPOSE To propose a straightforward and time-efficient quality assurance (QA) approach of beam time delay for respiratory-gated radiotherapy and validate the proposed method on typical respiratory gating systems, Catalyst™ and AlignRT™. METHODS The QA apparatus was composed of a motion platform and a Winston-Lutz cube phantom (WL3) embedded with metal balls. The apparatus was first scanned in CT-Sim and two types of QA plans specific for beam on and beam off time delay, respectively, were designed. Static reference images and motion testing images of the WL3 cube were acquired with EPID. By comparing the position differences of the embedded metal balls in the motion and reference images, beam time delays were determined. The proposed approach was validated on three linacs with either Catalyst™ or AlignRT™ respiratory gating systems. To investigate the impact of energy and dose rate on beam time delay, a range of QA plans with Eclipse (V15.7) were devised with varying energy and dose rates. RESULTS For all energies, the beam on time delays in AlignRT™ V6.3.226, AlignRT™ V7.1.1, and Catalyst™ were 92.13 ± $ \pm $ 5.79 ms, 123.11 ± $ \pm $ 6.44 ms, and 303.44 ± $ \pm $ 4.28 ms, respectively. The beam off time delays in AlignRT™ V6.3.226, AlignRT™ V7.1.1, and Catalyst™ were 121.87 ± $ \pm $ 1.34 ms, 119.33 ± $ \pm $ 0.75 ms, and 97.69 ± $ \pm $ 2.02 ms, respectively. Furthermore, the beam on delays decreased slightly as dose rates increased for all gating systems, whereas the beam off delays remained unaffected. CONCLUSIONS The validation results demonstrate the proposed QA approach of beam time delay for respiratory-gated radiotherapy was both reproducible and time-efficient to practice for institutions to customize accordingly.
Collapse
Affiliation(s)
- Kaining Yao
- Key laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing)Department of Radiation OncologyPeking University Cancer Hospital & InstituteBeijingChina
| | - Meijiao Wang
- Key laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing)Department of Radiation OncologyPeking University Cancer Hospital & InstituteBeijingChina
| | - Yi Du
- Key laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing)Department of Radiation OncologyPeking University Cancer Hospital & InstituteBeijingChina
- Institute of Medical TechnologyPeking University Health Science CenterBeijingChina
| | - Jiacheng Liu
- Key laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing)Department of Radiation OncologyPeking University Cancer Hospital & InstituteBeijingChina
| | - Qingying Wang
- Institute of Medical TechnologyPeking University Health Science CenterBeijingChina
| | - Ruoxi Wang
- Key laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing)Department of Radiation OncologyPeking University Cancer Hospital & InstituteBeijingChina
| | - Hao Wu
- Key laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing)Department of Radiation OncologyPeking University Cancer Hospital & InstituteBeijingChina
- Institute of Medical TechnologyPeking University Health Science CenterBeijingChina
| | - Haizhen Yue
- Key laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing)Department of Radiation OncologyPeking University Cancer Hospital & InstituteBeijingChina
| |
Collapse
|
2
|
Nakanishi D, Oita M, Fukunaga JI, Hirose TA, Yoshitake T, Sasaki M. Investigation of uncertainty in internal target volume definition for lung stereotactic body radiotherapy. Radiol Phys Technol 2023; 16:497-505. [PMID: 37713060 PMCID: PMC10665452 DOI: 10.1007/s12194-023-00737-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 08/18/2023] [Accepted: 08/19/2023] [Indexed: 09/16/2023]
Abstract
This study evaluated the validity of internal target volumes (ITVs) defined by three- (3DCT) and four-dimensional computed tomography (4DCT), and subsequently compared them with actual movements during treatment. Five patients with upper lobe lung tumors were treated with stereotactic body radiotherapy (SBRT) at 48 Gy in four fractions. Planning 3DCT images were acquired with peak-exhale and peak-inhale breath-holds, and 4DCT images were acquired in the cine mode under free breathing. Cine images were acquired using an electronic portal imaging device during irradiation. Tumor coverage was evaluated based on the manner in which the peak-to-peak breathing amplitude on the planning CT covered the range of tumor motion (± 3 SD) during irradiation in the left-right, anteroposterior, and cranio-caudal (CC) directions. The mean tumor coverage of the 4DCT-based ITV was better than that of the 3DCT-based ITV in the CC direction. The internal margin should be considered when setting the irradiation field for 4DCT. The proposed 4DCT-based ITV can be used as an efficient approach in free-breathing SBRT for upper-lobe tumors of the lung because its coverage is superior to that of 3DCT.
Collapse
Affiliation(s)
- Daiki Nakanishi
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1, Maidashi Higashi-Ku, Fukuoka, 812-8582, Japan
- Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University, 3-1-1 Tsushima-Naka, Kita-Ku, Okayama, 700-8530, Japan
| | - Masataka Oita
- Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University, 3-1-1 Tsushima-Naka, Kita-Ku, Okayama, 700-8530, Japan.
| | - Jun-Ichi Fukunaga
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1, Maidashi Higashi-Ku, Fukuoka, 812-8582, Japan
| | - Taka-Aki Hirose
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1, Maidashi Higashi-Ku, Fukuoka, 812-8582, Japan
| | - Tadamasa Yoshitake
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1, Maidashi Higashi-Ku, Fukuoka, 812-8582, Japan
| | - Motoharu Sasaki
- Graduate School of Biomedical Sciences, Tokushima University, 3-18-15 Kuramoto-Cho, Tokushima, Tokushima, 770-8503, Japan
| |
Collapse
|
3
|
Tan HQ, Koh CWY, Tan LKR, Lew KS, Chua CGA, Ang KW, Lee JCL, Park SY. A transit portal dosimetry method for respiratory gating quality assurance with a dynamic 3D printed tumor phantom. J Appl Clin Med Phys 2022; 23:e13560. [PMID: 35147283 PMCID: PMC9121038 DOI: 10.1002/acm2.13560] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Revised: 12/27/2021] [Accepted: 01/29/2022] [Indexed: 11/21/2022] Open
Abstract
BACKGROUNDS Respiratory gating is one of the motion management techniques that is used to deliver radiation dose to a tumor at a specific position under free breathing. However, due to the dynamic feedback process of this approach, regular equipment quality assurance (QA) and patient-specific QA checks need to be performed. This work proposes a new QA methodology using electronic portal imaging detector (EPID) to determine the target localization accuracy of phase gating. METHODS QA tools comprising 3D printed spherical tumor phantoms, programmable stages, and an EPID detector are characterized and assembled. Algorithms for predicting portal dose (PD) through moving phantoms are developed and verified using gamma analysis for two spherical tumor phantoms (2 cm and 4 cm), two different 6 MV volumetric modulated arc therapy plans, and two different gating windows (30%-70% and 40%-60%). Comparison between the two gating windows is then performed using the Wilcoxon signed-rank test. An optimizer routine, which is used to determine the optimal window, based on maximal gamma passing rate (GPR), was applied to an actual breathing curve and breathing plan. This was done to ascertain if our method yielded a similar result with the actual gating window. RESULTS High GPRs of more than 97% and 91% were observed when comparing the predicted PD with the measured PD in moving phantom at 2 mm/2% and 1 mm/1% levels, respectively. Analysis of gamma heatmaps shows an excellent agreement with the tumor phantom. The GPR of 40%-60% PD was significantly lower than that of the 30%-70% PD at the 1 mm/1% level (p = 0.0064). At the 2 mm/2% level, no significant differences were observed. The optimizer routine could accurately predict the center of the gating window to within a 10% range. CONCLUSION We have successfully performed and verified a new method for QA with the use of a moving phantom with EPID for phase gating with real-time position management.
Collapse
Affiliation(s)
- Hong Qi Tan
- Division of Radiation OncologyNational Cancer CentreSingaporeSingapore
| | | | | | - Kah Seng Lew
- Division of Radiation OncologyNational Cancer CentreSingaporeSingapore
| | | | - Khong Wei Ang
- Division of Radiation OncologyNational Cancer CentreSingaporeSingapore
| | - James Cheow Lei Lee
- Division of Radiation OncologyNational Cancer CentreSingaporeSingapore
- Division of Physics and Applied PhysicsNanyang Technological UniversitySingaporeSingapore
| | - Sung Yong Park
- Division of Radiation OncologyNational Cancer CentreSingaporeSingapore
- Oncology Academic Clinical ProgrammeDuke‐NUS Medical SchoolSingaporeSingapore
| |
Collapse
|
4
|
Selection of patient for gated treatment based on the information from 4DCT imaging in stereotactic body radiotherapy of non-small cell lung cancer. JOURNAL OF RADIOTHERAPY IN PRACTICE 2019. [DOI: 10.1017/s1460396918000614] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
AbstractPurposeStereotactic body radiotherapy (SBRT) is widely used for the treatment of stage-I non-small cell lung cancer (NSCLC). Patient-specific motion correlated with 4DCT could be essential for hypofractionated SBRT. All patients undergoing SBRT do not require motion management during the dose delivery. The objective of this study was to evaluate which patient may benefit from Gated SBRT.Materials and methodsTreatment planning of 20 patients of stage-I NSCLC was analysed. Conventional and 4DCT scans were taken. Internal target volume as well as planning target volume (ITV and PTV) were determined in the CT data sets. PTVall phases created using 4DCT data sets and PTV15mm created using conventional CT data were compared. Also, ITVall phases were compared with ITV created from maximum intensity projections (ITVMIP). Suitability of patients for motion management-based treatment delivery was also evaluated.ResultsThe average ITVMIP to ITVall phases ratio is 1·06 indicating good agreement between them. Based on the ratio of intensity projections, 9 out of 17 patients were found suitable for our existing gated treatment.Conclusion4D CT is the main requirement in SBRT to identify the patients who can benefit from motion management during the dose delivery.
Collapse
|
5
|
Effect of dose-delivery time for flattened and flattening filter-free photon beams based on microdosimetric kinetic model. PLoS One 2018; 13:e0206673. [PMID: 30462672 PMCID: PMC6248938 DOI: 10.1371/journal.pone.0206673] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2018] [Accepted: 10/17/2018] [Indexed: 11/19/2022] Open
Abstract
The effect of dose-delivery time with flattening filter (FF) and flattening filter-free (FFF) photon beams based on microdosimetric kinetic model (MKM) was investigated in this study. Monte Carlo simulation with the particle and heavy ion transport code system (PHITS) was performed to calculate the dose-mean lineal energy yD (keV/μm) of FF and FFF 6 MV photon beams using the IAEA phase-space files of Varian TrueBeam linear accelerator. Human non-small cell lung cancer NCI-H460 cells were used to determine the MKM parameters under the condition that dose-delivery times with continuous irradiation were 1, 5, 10, 30, and 60 min, and the adsorbed dose was 2, 4, and 8 Gy in this study. In addition, the relative biological effectiveness (RBE) of FF and FFF photon beams were calculated for evaluating the effect of dose delivery time. The RBE of FF decreased to 99.8% and 97.5% with 5 and 60 min for 2 Gy in comparison to 99.6% and 95.1% for 8 Gy, respectively. Meanwhile, that of FFF decreased to 99.5% and 94.9% with 5 and 60 min for 2 Gy in comparison to 99.5% and 94.9% for 8 Gy, respectively. Dose-delivery time has an effect on the RBE with photon beams. In other words, the dose-delivery time should be considered during radiation therapy. Furthermore, FFF photon beams were an effective irradiation method compared to FF in dose-delivery time on account of improving clinic throughput.
Collapse
|
6
|
|
7
|
Jermoumi M, Xie R, Cao D, Housley DJ, Shepard DM. Does gated beam delivery impact delivery accuracy on an Elekta linac? J Appl Clin Med Phys 2017; 18:90-95. [PMID: 28291908 PMCID: PMC5689903 DOI: 10.1002/acm2.12020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2016] [Accepted: 10/04/2016] [Indexed: 11/17/2022] Open
Abstract
In this study, we evaluated the performance of an Elekta linac in the delivery of gated radiotherapy. Delivery accuracy was examined with an emphasis on the impact of using short gating windows (low monitor unit beam-on segments) or long beam hold times. The performance was assessed using a 20cm by 20cm open field with the radiation delivered using a range of beam-on and beam-off time periods. Gated delivery measurements were also performed for two SBRT plans delivered using volumetric modulated arc therapy (VMAT). Tests included both free-breathing based gating (covering a variety of gating windows) and simulated breath-hold based gating. An IBA MatriXX 2D ion chamber array was used for data collection, and the gating accuracy at low MU was evaluated using gamma passing rates. For the 20 cm by 20 cm open field, the measurements generally showed close agreement between the gated and non-gated beam deliveries. Discrepancies, however, began to appear with a 5-to-1 ratio of the beam-off to beam-on times. The discrepancies observed for these tight gating windows can be attributed to the small number of monitor units delivered during each beam-on segment. Dose distribution analysis from the delivery of the two SBRT plans showed gamma passing rates (± 1%, 2%/1 mm) in the range of 95% to 100% for gating windows of 25%, 38%, 50%, 63%, 75%, and 83%. Using a simulated sinusoidal breathing signal with a 4 second period, the gamma passing rate of free-breathing gating and breath-hold gating deliveries were measured in the range of 95.7% to 100%. In conclusion, the results demonstrate that Elekta linacs can accurately deliver respiratory gated treatments for both free-breathing and breath-hold patients. Some caution should be exercised with the use of very tight gating windows.
Collapse
Affiliation(s)
- Mohammed Jermoumi
- Department of Radiation OncologySwedish Cancer InstituteSeattleWAUSA
| | - Roger Xie
- Department of Radiation OncologyIronwood Cancer and Research CenterScottsdaleAZUSA
| | - Daliang Cao
- Department of Radiation OncologySwedish Cancer InstituteSeattleWAUSA
| | - David J. Housley
- Department of Radiation OncologySwedish Cancer InstituteSeattleWAUSA
| | - David M. Shepard
- Department of Radiation OncologySwedish Cancer InstituteSeattleWAUSA
| |
Collapse
|
8
|
Ko YE, Cho B, Kim SS, Song SY, Choi EK, Ahn SD, Yi B. Improving Delivery Accuracy of Stereotactic Body Radiotherapy to a Moving Tumor Using Simplified Volumetric Modulated Arc Therapy. PLoS One 2016; 11:e0158053. [PMID: 27333199 PMCID: PMC4917108 DOI: 10.1371/journal.pone.0158053] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2016] [Accepted: 06/09/2016] [Indexed: 12/26/2022] Open
Abstract
PURPOSE To develop a simplified volumetric modulated arc therapy (VMAT) technique for more accurate dose delivery in thoracic stereotactic body radiation therapy (SBRT). METHODS AND MATERIALS For each of the 22 lung SBRT cases treated with respiratory-gated VMAT, a dose rate modulated arc therapy (DrMAT) plan was retrospectively generated. A dynamic conformal arc therapy plan with 33 adjoining coplanar arcs was designed and their beam weights were optimized by an inverse planning process. All sub-arc beams were converted into a series of control points with varying MLC segment and dose rates and merged into an arc beam for a DrMAT plan. The plan quality of original VMAT and DrMAT was compared in terms of target coverage, compactness of dose distribution, and dose sparing of organs at risk. To assess the delivery accuracy, the VMAT and DrMAT plans were delivered to a motion phantom programmed with the corresponding patients' respiratory signal; results were compared using film dosimetry with gamma analysis. RESULTS The plan quality of DrMAT was equivalent to that of VMAT in terms of target coverage, dose compactness, and dose sparing for the normal lung. In dose sparing for other critical organs, DrMAT was less effective than VMAT for the spinal cord, heart, and esophagus while being well within the limits specified by the Radiation Therapy Oncology Group. Delivery accuracy of DrMAT to a moving target was similar to that of VMAT using a gamma criterion of 2%/2mm but was significantly better using a 2%/1mm criterion, implying the superiority of DrMAT over VMAT in SBRT for thoracic/abdominal tumors with respiratory movement. CONCLUSION We developed a DrMAT technique for SBRT that produces plans of a quality similar to that achieved with VMAT but with better delivery accuracy. This technique is well-suited for small tumors with motion uncertainty.
Collapse
Affiliation(s)
- Young Eun Ko
- Department of Radiation Oncology, Ulsan University Hospital, Ulsan, Korea
| | - Byungchul Cho
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Su Ssan Kim
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Si Yeol Song
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Eun Kyung Choi
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Seung Do Ahn
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Byongyong Yi
- Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland, United States of America
| |
Collapse
|