1
|
Niu X, Zhang Y, Lai Z, Huang X, Gao J, Lu F, Chang Q, Yuan Y. Preoperative Short-Term High Carbohydrate Diet Provides More High-Quality Transplantable Fat and Improves the Outcome of Fat Grafts in Mice. Aesthet Surg J 2022; 42:NP531-NP545. [PMID: 35460566 DOI: 10.1093/asj/sjac105] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Patients with a low body mass index may have inadequate high-quality adipose tissue for transplantation. The influence of high-energy diets on adipose tissue and graft retention remains unknown. OBJECTIVES We explored inguinal fat pad alternation in mice fed on a short-time high-fat diet (HFD) or a high-carbohydrate diet (HCD) preoperatively and the morphological and histological differences after transplantation. METHODS Mice were fed HFD (60% kilocalories from fat, 20% from carbohydrate), HCD (9.3% kilocalories from fat, 80.1% from carbohydrate), or normal (12% kilocalories from fat, 67% kilocalories from carbohydrate) diets for 2 or 4 weeks. Histological analyses were carried out following hematoxylin and eosin staining, and CD34 and proliferating cell nuclear antigen immunostaining. The uncoupling protein-1 (UCP-1) expression was determined by western blotting. Fat pads from each group were grafted into the dorsal region of the recipient mice and morphological and histological changes were determined 4, 8, and 12 weeks post-transplantation. Vascular endothelial growth factor α and platelet-derived growth factor α expression were determined using quantitative polymerase chain reaction. RESULTS The inguinal fat pad volume increased in the HFD and HCD groups. The presence of multilocular adipocytes in inguinal fat of HCD-fed mice, combined with the increased UCP-1 content, suggested adipocyte browning. HCD grafts showed higher volume retention and reduced oil cyst formation, possibly attributed to better angiogenesis and adipogenesis. CONCLUSIONS HCD enlarged adipose tissue and improved grafts survival rates, which may be due to the browning of fat before grafting and enhanced angiogenesis after grafting.
Collapse
Affiliation(s)
- Xingtang Niu
- Department of Plastic Surgery, Nanfang Hospital, Southern Medical University , Guangzhou, Guangdong , China
| | - Yuchen Zhang
- Department of Plastic Surgery, Nanfang Hospital, Southern Medical University , Guangzhou, Guangdong , China
| | - Zhuhao Lai
- Department of Plastic Surgery, Nanfang Hospital, Southern Medical University , Guangzhou, Guangdong , China
| | - Xiaoqi Huang
- Department of Plastic Surgery, Nanfang Hospital, Southern Medical University , Guangzhou, Guangdong , China
| | - Jianhua Gao
- Department of Plastic Surgery, Nanfang Hospital, Southern Medical University , Guangzhou, Guangdong , China
| | - Feng Lu
- Department of Plastic Surgery, Nanfang Hospital, Southern Medical University , Guangzhou, Guangdong , China
| | - Qiang Chang
- Department of Plastic Surgery, Nanfang Hospital, Southern Medical University , Guangzhou, Guangdong , China
| | - Yi Yuan
- Department of Plastic Surgery, Nanfang Hospital, Southern Medical University , Guangzhou, Guangdong , China
| |
Collapse
|
2
|
Alzyoud K, Hogg P, Snaith B, Flintham K, England A. Impact of body part thickness on AP pelvis radiographic image quality and effective dose. Radiography (Lond) 2018; 25:e11-e17. [PMID: 30599841 DOI: 10.1016/j.radi.2018.09.001] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2018] [Revised: 09/04/2018] [Accepted: 09/06/2018] [Indexed: 10/28/2022]
Abstract
INTRODUCTION Within medical imaging variations in patient size can generate challenges, especially when selecting appropriate acquisition parameters. This experiment sought to evaluate the impact of increasing body part thickness on image quality (IQ) and effective dose (E) and identify optimum exposure parameters. METHODS An anthropomorphic pelvis phantom was imaged with additional layers (1-15 cm) of animal fat as a proxy for increasing body thickness. Acquisitions used the automatic exposure control (AEC), 100 cm source to image distance (SID) and a range of tube potentials (70-110 kVp). IQ was evaluated physically and perceptually. E was estimated using PCXMC software. RESULTS For all tube potentials, signal to noise ratio (SNR) and contrast to noise ratio (CNR) deceased as body part thickness increased. 70 kVp produced the highest SNR (46.6-22.6); CNR (42.8-17.6). Visual grading showed that the highest IQ scores were achieved using 70 and 75 kVp. As thickness increases, E increased exponentially (r = 0.96; p < 0.001). Correlations were found between visual and physical IQ (SNR r = 0.97, p < 0.001; CNR r = 0.98, p < 0.001). CONCLUSION To achieve an optimal IQ across the range of thicknesses, lower kVp settings were most effective. This is at variance with professional practice as there is a tendency for radiographers to increase kVp as thickness increases. Dose reductions were experienced at higher kVp settings and are a valid method for optimisation when imaging larger patients.
Collapse
Affiliation(s)
- K Alzyoud
- School of Health Sciences, University of Salford, Salford M6 6PU, United Kingdom; Faculty of Allied Health Sciences, Hashemite University, Zarqa, Jordan.
| | - P Hogg
- School of Health Sciences, University of Salford, Salford M6 6PU, United Kingdom.
| | - B Snaith
- The Mid Yorkshire Hospitals NHS Trust, Wakefield WF1 4DG, United Kingdom; University of Bradford, Bradford BD7 1DP, United Kingdom.
| | - K Flintham
- The Mid Yorkshire Hospitals NHS Trust, Wakefield WF1 4DG, United Kingdom.
| | - A England
- School of Health Sciences, University of Salford, Salford M6 6PU, United Kingdom.
| |
Collapse
|
3
|
Comparison of T1-weighted 2D TSE, 3D SPGR, and two-point 3D Dixon MRI for automated segmentation of visceral adipose tissue at 3 Tesla. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2016; 30:139-151. [PMID: 27638089 DOI: 10.1007/s10334-016-0588-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2016] [Revised: 08/28/2016] [Accepted: 08/29/2016] [Indexed: 12/17/2022]
Abstract
OBJECTIVES To evaluate and compare conventional T1-weighted 2D turbo spin echo (TSE), T1-weighted 3D volumetric interpolated breath-hold examination (VIBE), and two-point 3D Dixon-VIBE sequences for automatic segmentation of visceral adipose tissue (VAT) volume at 3 Tesla by measuring and compensating for errors arising from intensity nonuniformity (INU) and partial volume effects (PVE). MATERIALS AND METHODS The body trunks of 28 volunteers with body mass index values ranging from 18 to 41.2 kg/m2 (30.02 ± 6.63 kg/m2) were scanned at 3 Tesla using three imaging techniques. Automatic methods were applied to reduce INU and PVE and to segment VAT. The automatically segmented VAT volumes obtained from all acquisitions were then statistically and objectively evaluated against the manually segmented (reference) VAT volumes. RESULTS Comparing the reference volumes with the VAT volumes automatically segmented over the uncorrected images showed that INU led to an average relative volume difference of -59.22 ± 11.59, 2.21 ± 47.04, and -43.05 ± 5.01 % for the TSE, VIBE, and Dixon images, respectively, while PVE led to average differences of -34.85 ± 19.85, -15.13 ± 11.04, and -33.79 ± 20.38 %. After signal correction, differences of -2.72 ± 6.60, 34.02 ± 36.99, and -2.23 ± 7.58 % were obtained between the reference and the automatically segmented volumes. A paired-sample two-tailed t test revealed no significant difference between the reference and automatically segmented VAT volumes of the corrected TSE (p = 0.614) and Dixon (p = 0.969) images, but showed a significant VAT overestimation using the corrected VIBE images. CONCLUSION Under similar imaging conditions and spatial resolution, automatically segmented VAT volumes obtained from the corrected TSE and Dixon images agreed with each other and with the reference volumes. These results demonstrate the efficacy of the signal correction methods and the similar accuracy of TSE and Dixon imaging for automatic volumetry of VAT at 3 Tesla.
Collapse
|
4
|
Baum T, Cordes C, Dieckmeyer M, Ruschke S, Franz D, Hauner H, Kirschke JS, Karampinos DC. MR-based assessment of body fat distribution and characteristics. Eur J Radiol 2016; 85:1512-8. [PMID: 26905521 DOI: 10.1016/j.ejrad.2016.02.013] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2015] [Revised: 02/03/2016] [Accepted: 02/09/2016] [Indexed: 12/14/2022]
Abstract
The assessment of body fat distribution and characteristics using magnetic resonance (MR) methods has recently gained significant attention as it further extends our pathophysiological understanding of diseases including obesity, metabolic syndrome, or type 2 diabetes mellitus, and allows more detailed insights into treatment response and effects of lifestyle interventions. Therefore, the purpose of this study was to review the current literature on MR-based assessment of body fat distribution and characteristics. PubMed search was performed to identify relevant studies on the assessment of body fat distribution and characteristics using MR methods. T1-, T2-weighted MR Imaging (MRI), Magnetic Resonance Spectroscopy (MRS), and chemical shift-encoding based water-fat MRI have been successfully used for the assessment of body fat distribution and characteristics. The relationship of insulin resistance and serum lipids with abdominal adipose tissue (i.e. subcutaneous and visceral adipose tissue), liver, muscle, and bone marrow fat content have been extensively investigated and may help to understand the underlying pathophysiological mechanisms and the multifaceted obese phenotype. MR methods have also been used to monitor changes of body fat distribution and characteristics after interventions (e.g. diet or physical activity) and revealed distinct, adipose tissue-specific properties. Lastly, chemical shift-encoding based water-fat MRI can detect brown adipose tissue which is currently the focus of intense research as a potential treatment target for obesity. In conclusion, MR methods reliably allow the assessment of body fat distribution and characteristics. Irrespective of the promising findings based on these MR methods the clinical usefulness remains to be established.
Collapse
Affiliation(s)
- Thomas Baum
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technische Universität München, Munich, Germany.
| | - Christian Cordes
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technische Universität München, Munich, Germany
| | - Michael Dieckmeyer
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technische Universität München, Munich, Germany
| | - Stefan Ruschke
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technische Universität München, Munich, Germany
| | - Daniela Franz
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technische Universität München, Munich, Germany
| | - Hans Hauner
- Else Kröner Fresenius Center for Nutritional Medicine, Klinikum rechts der Isar, Technische Universität München, Munich, Germany; ZIEL Research Center for Nutrition and Food Sciences, Technische Universität München, Germany
| | - Jan S Kirschke
- Section of Diagnostic and Interventional Neuroradiology, Klinikum rechts der Isar, Technische Universität München, Munich, Germany
| | - Dimitrios C Karampinos
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technische Universität München, Munich, Germany
| |
Collapse
|
5
|
Toro-Ramos T, Paley C, Pi-Sunyer FX, Gallagher D. Body composition during fetal development and infancy through the age of 5 years. Eur J Clin Nutr 2015; 69:1279-89. [PMID: 26242725 PMCID: PMC4680980 DOI: 10.1038/ejcn.2015.117] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2014] [Revised: 06/08/2015] [Accepted: 06/11/2015] [Indexed: 02/07/2023]
Abstract
Fetal body composition is an important determinant of body composition at birth, and it is likely to be an important determinant at later stages in life. The purpose of this work is to provide a comprehensive overview by presenting data from previously published studies that report on body composition during fetal development in newborns and the infant/child through 5 years of age. Understanding the changes in body composition that occur both in utero and during infancy and childhood, and how they may be related, may help inform evidence-based practice during pregnancy and childhood. We describe body composition measurement techniques from the in utero period to 5 years of age, and identify gaps in knowledge to direct future research efforts. Available literature on chemical and cadaver analyses of fetal studies during gestation is presented to show the timing and accretion rates of adipose and lean tissues. Quantitative and qualitative aspects of fetal lean and fat mass accretion could be especially useful in the clinical setting for diagnostic purposes. The practicality of different pediatric body composition measurement methods in the clinical setting is discussed by presenting the assumptions and limitations associated with each method that may assist the clinician in characterizing the health and nutritional status of the fetus, infant and child. It is our hope that this review will help guide future research efforts directed at increasing the understanding of how body composition in early development may be associated with chronic diseases in later life.
Collapse
Affiliation(s)
- T Toro-Ramos
- Department of Medicine, New York Obesity Nutrition Research Center, St Luke’s-Roosevelt Hospital, New York, NY, USA
- Department of Medicine, Institute of Human Nutrition, Columbia University, New York, NY, USA
| | - C Paley
- Department of Medicine, New York Obesity Nutrition Research Center, St Luke’s-Roosevelt Hospital, New York, NY, USA
- Department of Pediatrics, St Luke’s-Roosevelt Hospital, New York, NY, USA
| | - FX Pi-Sunyer
- Department of Medicine, New York Obesity Nutrition Research Center, St Luke’s-Roosevelt Hospital, New York, NY, USA
- Department of Medicine, Institute of Human Nutrition, Columbia University, New York, NY, USA
| | - D Gallagher
- Department of Medicine, New York Obesity Nutrition Research Center, St Luke’s-Roosevelt Hospital, New York, NY, USA
- Department of Medicine, Institute of Human Nutrition, Columbia University, New York, NY, USA
| |
Collapse
|