1
|
Meier J, Hembus J, Bader R, Vogel D. Computer-based analysis of the taper connection strength of different revision head and adapter sleeve designs. BIOMED ENG-BIOMED TE 2024; 69:199-209. [PMID: 37698840 DOI: 10.1515/bmt-2023-0066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Accepted: 08/28/2023] [Indexed: 09/13/2023]
Abstract
OBJECTIVES Ceramic revision heads, equipped with titanium adapter sleeves, are used in femoral head revision in total hip arthroplasty to avoid ceramic fracture due to the damaged taper. METHODS A finite element analysis of the taper connection strength of revision heads with varying head diameters combined with adapter sleeves of different lengths was conducted. The influence of various assembly forces, head diameter, and length of the adapter sleeves was evaluated. For two combinations, the pattern of contact pressure was evaluated when applying a simplified joint load (3 kN, 45° load angle). Experimental validation was conducted with 36 mm heads and adapter sleeves in size S, as well as 28 mm heads and adapter sleeves in size XL. RESULTS The pull-off force increased with higher assembly forces. Using larger head diameters and adapter sleeves led to decreased pull-off forces, a reduced contact surface, and less contact pressure. The contact pressure showed significant peaks and a diagonal pattern under 45° angle loading when assembly forces were less than 4 kN, and larger adapter sleeves were utilized. CONCLUSION A sufficient assembly force should be ensured intraoperatively, especially with an increasing head diameter and adapter sleeve size, as lower assembly forces might lead to reduced taper connection strength.
Collapse
Affiliation(s)
- Johanna Meier
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Jessica Hembus
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Rainer Bader
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Danny Vogel
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| |
Collapse
|
2
|
Godoy M, Sipek K, Gustafson JA, Yuh C, Levine BR, Pourzal R, Lundberg HJ. Effect of Femoral Head Material, Surgeon Experience, and Assembly Technique on Simulated Head-Neck Total Hip Arthroplasty Impaction Forces. J Arthroplasty 2024; 39:507-513.e1. [PMID: 37598779 PMCID: PMC10850914 DOI: 10.1016/j.arth.2023.08.049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 08/10/2023] [Accepted: 08/11/2023] [Indexed: 08/22/2023] Open
Abstract
BACKGROUND There is no standard method for assembling the femoral head onto the femoral stem during total hip arthroplasty (THA). This study aimed to measure and record dynamic 3-dimensional (3D) THA head-neck assembly loads from residents, fellows, and attending surgeons, for metal and ceramic femoral heads. METHODS An instrumented apparatus measured dynamic 3D forces applied through the femoral stem taper in vitro for 31 surgeons (11 attendings, 14 residents, 6 fellows) using their preferred technique (ie, number of hits or mallet strikes). Outcome variables included peak axial force, peak resultant force, impulse of the resultant force, loading rate of the resultant force, and off-axis angle. They were compared between femoral head material, surgeon experience level, and the number of hits per trial. RESULTS Average peak axial force was 6.92 ± 2.11kN for all surgeons. No significant differences were found between femoral head material. Attendings applied forces more "on-axis" as compared to both residents and fellows. Nine surgeons assembled the head with 1 hit, 3 with 2 hits, 14 with 3 hits, 2 with 4 hits, and 3 with ≥5 hits. The first hit of multihit trials was significantly lower than single-hit trials for all outcome measures except the off-axis angle. The last hit of multihit trials had a significantly lower impulse of resultant force than single-hit trials. CONCLUSION Differences in applied 3D force-time curve dynamic characteristics were found between surgeon experience level and single and multihit trials. No significant differences were found between femoral head material.
Collapse
Affiliation(s)
- Michael Godoy
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL USA
| | - Kirsten Sipek
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL USA
| | | | - Catherine Yuh
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL USA
| | - Brett R. Levine
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL USA
| | - Robin Pourzal
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL USA
| | - Hannah J. Lundberg
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL USA
| |
Collapse
|
3
|
Diaz-Lopez RA, Wen PH, Shelton JC. Influence of Taper surface topographies on contact deformation and stresses. J Mech Behav Biomed Mater 2023; 148:106213. [PMID: 37952504 DOI: 10.1016/j.jmbbm.2023.106213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 10/16/2023] [Accepted: 10/26/2023] [Indexed: 11/14/2023]
Abstract
The role of bore and trunnion surface topography on the failure rate of total hip joint replacements due to trunnionosis is not clear despite significant variations in the design of taper components between manufacturers. Taper surface topography, along with other taper design parameters such as clearance, diameter, and assembly force, determine the initial interlock of the contacting surfaces after assembly; this has been related to relative motions that can cause fretting and corrosion at the taper interface. However, in most in-silico parametrical taper studies associated with taper micromotions, the bore and trunnion surfaces have been simplified using a flat surface and/or sinusoidal functions to mimic the surface roughness. The current study tests the hypothesis that the use of simple geometrical functions for the taper surface topography can predict the surface mechanics developed in assembled tapers. Measured and simulated surfaces of bores and trunnions were characterised using common roughness parameters and spectral density estimations. Using the same characterised surface profiles, 2D Finite Element (FE) models of CoCr alloy femoral heads and Ti alloy trunnions were developed. Models simulated assembly conditions at different resultant forces ranging from 0.5 to 4.0 kN, contact conditions were determined and associated with their topographical characteristics. Measured surfaces of bore and trunnion components comprise up to seven dominant spatial frequencies. Flattening of the trunnion microgrooved peaks was observed during the assembly of the taper. When the femoral head bore and trunnion topography were both considered a reduced number of microgrooved peaks were in contact, from 51 in an idealised taper surfaces to 35 in measured surfaces using an assembly reaction force of 4 kN. The contact points in the models developed high plastic strains, which were greater than that associated with failure of the material. Results showed that line and sine wave functions over estimate contact points at the taper interface compared to those surfaces that consider roughness and peak variation. These findings highlight the important role of modelling the full surface topography on the taper contact mechanics, as surface variations in the roughness and waviness change the performance of tapers.
Collapse
Affiliation(s)
- R A Diaz-Lopez
- School of Engineering and Materials Science, Queen Mary University of London, UK
| | - P H Wen
- School of Engineering and Materials Science, Queen Mary University of London, UK
| | - J C Shelton
- School of Engineering and Materials Science, Queen Mary University of London, UK.
| |
Collapse
|
4
|
Godoy M, Gustafson JA, Hertzler JS, Bischoff JE, Pourzal R, Lundberg HJ. Model validation for estimating taper microgroove deformation during total hip arthroplasty head-neck assembly. J Biomech 2022; 140:111172. [PMID: 35696772 PMCID: PMC9801958 DOI: 10.1016/j.jbiomech.2022.111172] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Revised: 03/25/2022] [Accepted: 05/31/2022] [Indexed: 01/03/2023]
Abstract
Total hip arthroplasty (THA) failure and the need for revision surgery can result from fretting-corrosion damage of the head-neck modular taper junctions. Prior work has shown that implant geometry, such as microgrooves, influences damage on retrieved implants. Microgroove deformation within the modular taper junction occurs when the female head taper meets the male stem taper during THA surgical procedure. The objective of this work was to validate microgroove deformation after head-neck THA assembly as calculated by finite element analysis (FEA). Four 28 mm CoCrMo head tapers and four Ti6Al4V stem tapers were scanned via white light interferometry. Heads were assembled onto stem tapers until 6kN reaction force was achieved, followed by head removal using a cut-off machine. The stem tapers were then rescanned and analyzed. Simultaneously, a 2D axisymmetric FEA model was developed and assembled per implant geometries and experimental data. For experiments and FEA, the mean change in microgroove height was 1.23 µm and 1.40 µm, respectively. The largest microgroove height change occurred on the proximal stem taper due to the conical angles of the head and stem tapers. FEA showed that the head-stem assembly induced high stresses and microgroove peaks flattening. 76-89% and 91-100% of the microgrooves in the experiments and FEA, respectively, showed height changes along the contact length of the stem taper. A validated FEA model of THA head-neck modular junction contact mechanics is essential to identifying implant geometries and surface topographies that can potentially minimize the risk of fretting and fretting-corrosion at modular junctions.
Collapse
Affiliation(s)
- Michael Godoy
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | | | | | | | - Robin Pourzal
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Hannah J. Lundberg
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| |
Collapse
|
5
|
Wade A, Webster F, Beadling AR, Bryant MG. Importance of surgical assembly technique on the engagement of 12/14 modular tapers. Proc Inst Mech Eng H 2022; 236:158-168. [PMID: 34693823 PMCID: PMC8688978 DOI: 10.1177/09544119211053066] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Accepted: 09/19/2021] [Indexed: 11/30/2022]
Abstract
Fretting-corrosion at the modular taper junction in total hip replacements (THR), leading to implant failure, has been identified as a clinical concern and has received increased interest in recent years. There are many parameters thought to affect the performance of the taper junction, with the assembly process being one of the few consistently identified to have a direct impact. Despite this, the assembly process used by surgeons during THR surgery differs from a suggested 'ideal' process. For example, taper junctions of cutting tools should be pushed together rather than impacted, while ensuring as much concentricity as possible between the male and female taper and loading axis. This study devised six simple assembly methodologies to investigate how surgical variations affect the success of the compressive fit achieved at the taper interface compared to a controlled assembly method, designed to represent a more 'ideal' scenario. Key findings from this study suggest that a more successful and repeatable engagement can be achieved by quasi-statically loading the male and female taper concentrically with the loading axis. This was shown by a greater disassembly to assembly force ratio of 0.626 ± 0.07 when assembled using the more 'ideal' process, compared to 0.480 ± 0.05 when using a method closer to that used by a surgeon intraoperatively. Findings from this study can be used to help inform new surgical instrumentation and an improved surgical assembly method.
Collapse
Affiliation(s)
- A Wade
- School of Mechanical Engineering, Institute of Functional Surfaces, University of Leeds, Leeds, UK
| | - F Webster
- School of Mechanical Engineering, Institute of Functional Surfaces, University of Leeds, Leeds, UK
| | - AR Beadling
- School of Mechanical Engineering, Institute of Functional Surfaces, University of Leeds, Leeds, UK
| | - MG Bryant
- School of Mechanical Engineering, Institute of Functional Surfaces, University of Leeds, Leeds, UK
| |
Collapse
|
6
|
Mai PT, Bormann T, Müller U, Kretzer JP, Gibmeier J. Effect of surface topography and residual stress on the taper connection stability in total hip arthroplasty. J Mech Behav Biomed Mater 2022; 128:105119. [DOI: 10.1016/j.jmbbm.2022.105119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Revised: 01/10/2022] [Accepted: 02/03/2022] [Indexed: 11/26/2022]
|
7
|
Diaz-Lopez R, Wen P, Shelton J. Influence of taper design and loading on taper micromotion. J Mech Behav Biomed Mater 2022; 128:105106. [DOI: 10.1016/j.jmbbm.2022.105106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 10/05/2021] [Accepted: 01/25/2022] [Indexed: 11/24/2022]
|
8
|
Stockhausen KE, Riedel C, Belinski AV, Rothe D, Gehrke T, Klebig F, Gebauer M, Amling M, Citak M, Busse B. Variability in stem taper surface topography affects the degree of corrosion and fretting in total hip arthroplasty. Sci Rep 2021; 11:9348. [PMID: 33931680 PMCID: PMC8087796 DOI: 10.1038/s41598-021-88234-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Accepted: 03/19/2021] [Indexed: 12/29/2022] Open
Abstract
Degradation at the modular head-neck interface in total hip arthroplasty (THA) is predominately expressed in the form of corrosion and fretting, potentially causing peri-prosthetic failure by adverse reactions to metal debris. This retrieval study aimed to quantify variations in stem taper surface topographies and to assess the influence on the formation of corrosion and/or fretting in titanium alloy stem tapers combined with metal and ceramic heads. Four hip stem designs (Alloclassic, CLS, Bicontact and SL-Plus) were characterized using high-resolution 3D microscopy, and corrosion and fretting were rated using the Goldberg scoring scheme. Quantification of the taper surface topographies revealed a high variability in surface characteristics between threaded stem tapers: Alloclassic and CLS tapers feature deeply threaded trapezoid-shaped profiles with thread heights over 65 µm. The sawtooth-shaped Bicontact and triangular SL-Plus taper are characterized by low thread heights below 14 µm. Significantly lower corrosion and fretting scores were observed in lightly threaded compared to deeply threaded tapers in ceramic head combinations. No significant differences in corrosion or fretting scores with thread height were found in pairings with metal heads. Understanding the relationship between stem taper surface topography and the formation of corrosion and fretting could help to improve the performance of modern THAs and lead to longer-lasting clinical results.
Collapse
Affiliation(s)
- Kilian Elia Stockhausen
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 55a, 22529, Hamburg, Germany
| | - Christoph Riedel
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 55a, 22529, Hamburg, Germany
| | - Alex Victoria Belinski
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 55a, 22529, Hamburg, Germany.,Department of Mechanical Engineering, University of California, 6141 Etcheverry Hall, Berkeley, CA, USA
| | - Dorothea Rothe
- Department of Orthopedic Surgery, Helios ENDO-Klinik, Holstenstraße 2, 22767, Hamburg, Germany
| | - Thorsten Gehrke
- Department of Orthopedic Surgery, Helios ENDO-Klinik, Holstenstraße 2, 22767, Hamburg, Germany
| | - Felix Klebig
- Department of Orthopedic Surgery, Helios ENDO-Klinik, Holstenstraße 2, 22767, Hamburg, Germany
| | - Matthias Gebauer
- Department of Orthopedic Surgery, Helios ENDO-Klinik, Holstenstraße 2, 22767, Hamburg, Germany
| | - Michael Amling
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 55a, 22529, Hamburg, Germany
| | - Mustafa Citak
- Department of Orthopedic Surgery, Helios ENDO-Klinik, Holstenstraße 2, 22767, Hamburg, Germany
| | - Björn Busse
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 55a, 22529, Hamburg, Germany. .,Interdisciplinary Competence Center for Interface Research (ICCIR), Martinistr. 52, 20251, Hamburg, Germany. .,Forum Medical Technology Health Hamburg (FMTHH), Butenfeld 34, 22529, Hamburg, Germany.
| |
Collapse
|
9
|
Feyzi M, Fallahnezhad K, Taylor M, Hashemi R. The mechanics of head-neck taper junctions: What do we know from finite element analysis? J Mech Behav Biomed Mater 2021; 116:104338. [PMID: 33524892 DOI: 10.1016/j.jmbbm.2021.104338] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 12/16/2020] [Accepted: 01/15/2021] [Indexed: 12/18/2022]
Abstract
Modular hip implants are widely used in hip arthroplasty because of the advantages they can offer such as flexibility in material combinations and geometrical adjustments. The mechanical environment of the modular junction in the body is quite challenging due to the complex and varying off-axial mechanical loads of physical activities applied to a tapered interface of two contacting materials (head and neck) assembled by an impact force intraoperatively. Experimental analogies to the in-vivo condition of the taper junction are complex, expensive and time-consuming to implement; hence, computational simulations have been a preferred approach taken by researchers for studying the mechanics of these modular junctions that can help us understand their failure mechanisms and improve their design and longevity after implantation. This paper provides a clearer insight into the mechanics of the head-neck taper junction through a careful review on the finite element studies of the junction and their findings. The effects of various factors on the mechanical outputs namely: stresses, micromotions, and contact situations are reviewed and discussed. Also, the simulation methodology of the studies in the literature is compared. Research opportunities for future are scrutinised through tabulating data and information that have been carefully retrieved form the reported findings.
Collapse
Affiliation(s)
- Mohsen Feyzi
- College of Science and Engineering, Medical Device Research Institute, Flinders University, Tonsley, SA, 5042, Australia
| | - Khosro Fallahnezhad
- College of Science and Engineering, Medical Device Research Institute, Flinders University, Tonsley, SA, 5042, Australia
| | - Mark Taylor
- College of Science and Engineering, Medical Device Research Institute, Flinders University, Tonsley, SA, 5042, Australia
| | - Reza Hashemi
- College of Science and Engineering, Medical Device Research Institute, Flinders University, Tonsley, SA, 5042, Australia.
| |
Collapse
|
10
|
Abstract
The focus on taper corrosion in modular hip arthroplasty increased around 2007 as a result of clinical problems with large-head metal-on-metal (MoM) bearings on standard stems. Corrosion problems with bi-modular primary hip stems focused attention on this issue even more. Factors increasing the risk of taper corrosion were identified in laboratory and retrieval studies: stiffness of the stem neck, taper diameter and design, head diameter, offset, assembly force, head and stem material and loading. The high variability of the occurrence of corrosion in the clinical application highlights its multi-factorial nature, identifying the implantation procedure and patient-related factors as important additional factors for taper corrosion. Discontinuing the use of MoM has reduced the revisions due to metal-related pathologies dramatically from 49.7% (MoM > 32 mm), over 9.2% (MoM ⩽ 32 mm) to 0.8% (excluding all MoM). Further reduction can be achieved by omitting less stiff Ti-alloys and large metal heads (36 mm and above) against polyethylene (PE). Standardized taper assembly of smaller and ceramic heads will reduce the clinical occurrence of taper corrosion even further. If 36 mm heads are clinically indicated, only ceramic heads should be used. Taper-related problems will not comprise a major clinical problem anymore if the mentioned factors are respected.
Cite this article: EFORT Open Rev 2020;5:776-784. DOI: 10.1302/2058-5241.5.200013
Collapse
Affiliation(s)
| | | | - Georgi Wassilew
- Department for Orthopaedics and Orthopaedic Surgery, University of Greifswald, Greifswald, Germany
| | - Felix Prange
- TUHH Hamburg University of Technology, Hamburg, Germany
| | - Gerd Huber
- TUHH Hamburg University of Technology, Hamburg, Germany
| | - Carsten Perka
- Center for Musculoskeletal Surgery, Orthopedic Department, Charité - Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
11
|
Wade A, Beadling AR, Neville A, De Villiers D, Cullum CJ, Collins S, Bryant MG. Geometric Variations of Modular Head-Stem Taper Junctions of Total Hip Replacements. Med Eng Phys 2020; 83:34-47. [PMID: 32807346 DOI: 10.1016/j.medengphy.2020.07.017] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Revised: 06/03/2020] [Accepted: 07/13/2020] [Indexed: 10/23/2022]
Abstract
Taper degradation in Total Hip Replacements (THR) has been identified as a clinical concern, and the degradation occurring at these interfaces has received increased interest in recent years. Wear and corrosion products produced at the taper junction are associated with adverse local tissue responses, leading to early failure and revision surgery. Retrieval and in-vitro studies have found that variations in taper design affect degradation. However, there is a lack of consistent understanding within the literature of what makes a good taper interface. Previous studies assessed different design variations using their global parameters assuming a perfect cone such as: taper length, cone angle and diameters. This study assessed geometrical variations of as-manufactured head and stem tapers and any local deviations from their geometry. The purpose of this study was to provide a greater insight into possible engagement, a key performance influencing parameter predicted by Morse taper connection theory. This was achieved by taking measurements of twelve different commercially available male tapers and six female tapers using a coordinate measurement machine (CMM). The results suggested that engagement is specific to a particular head-stem couple. This is subject to both their micro-scale deviations, superimposed on their macro-scale differences. Differences in cone angles between female and male tapers from the same manufacturer was found to create a predominately proximal contact. However, distally mismatched couples are present in some metal-on-metal head-stem couples. On a local scale, different deviation patterns were observed from the geometry which appeared to be linked to the manufacturing process. Future work will look at using this measurement methodology to fully characterise an optimal modular taper junction for a THR prosthesis.
Collapse
Affiliation(s)
- A Wade
- University of Leeds, School of Mechanical Engineering, Institute of Functional Surfaces, Leeds, UK.
| | - A R Beadling
- University of Leeds, School of Mechanical Engineering, Institute of Functional Surfaces, Leeds, UK
| | - A Neville
- University of Leeds, School of Mechanical Engineering, Institute of Functional Surfaces, Leeds, UK
| | - D De Villiers
- MatOrtho Ltd, Mole Business Park, Randalls Rd, Surrey, UK
| | - C J Cullum
- MatOrtho Ltd, Mole Business Park, Randalls Rd, Surrey, UK
| | - S Collins
- MatOrtho Ltd, Mole Business Park, Randalls Rd, Surrey, UK
| | - M G Bryant
- University of Leeds, School of Mechanical Engineering, Institute of Functional Surfaces, Leeds, UK
| |
Collapse
|
12
|
Chaudhary M, Boruah S, Muratoglu OK, Varadarajan KM. Evaluation of pull-off strength and seating displacement of sleeved ceramic revision heads in modular hip arthroplasty. J Orthop Res 2020; 38:1523-1528. [PMID: 31769536 DOI: 10.1002/jor.24536] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2019] [Accepted: 11/12/2019] [Indexed: 02/04/2023]
Abstract
Corrosion in revision total hip arthroplasty can be mitigated using a ceramic head on a well-fixed in situ stem, but concerns of their early failure because of any surface defects on in situ stem necessitates the use of a titanium sleeve, which furnishes a factory-finish surface. These sleeves are manufactured in different sizes allowing neck-length adjustment. The strength of the taper junction of non-sleeved primary heads is well-investigated, but the influence of an interposed titanium sleeve on achieving a secure taper lock is unclear. Therefore, this study aimed to investigate the pull-off strength and seating displacement of revision ceramic heads and titanium taper sleeves. Two different head diameters and two different taper adapter sleeve offset lengths were mated with trunnions at two different impaction forces. The seating displacement and pull-off force was recorded for each specimen. Profilometry of the grooved outer surfaces of the sleeve and trunnion was done before and after testing to analyze the change in surface roughness. The influence of head diameter, sleeve offset, and impaction force on seating displacement and pull-off force was analyzed using analysis of covariance. Pull-off forces for 6 kN assembly force were approximately three times those for 2 kN. The head diameter did not have a significant effect on the measured parameters. Compared with short offset length sleeves, extra-long increased seating displacement by 31% and reduced pull-off forces by 15%. While sleeves of different offset lengths permit control of neck length, surgeons must be careful of the impact of this choice on the stability of implant. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 38:1523-1528, 2020.
Collapse
Affiliation(s)
- Miriam Chaudhary
- Technology Implementation Research Center, Massachusetts General Hospital, 55 Fruit Street, Boston, Massachusetts, 02114
| | - Sourabh Boruah
- Technology Implementation Research Center, Massachusetts General Hospital, 55 Fruit Street, Boston, Massachusetts, 02114
| | - Orhun K Muratoglu
- Harris Orthopaedics Laboratory, Massachusetts General Hospital, Boston, Massachusetts
| | - Kartik M Varadarajan
- Technology Implementation Research Center, Massachusetts General Hospital, 55 Fruit Street, Boston, Massachusetts, 02114
| |
Collapse
|
13
|
Haschke H, Falkenberg A, Morlock MM, Huber G. Do SiNx coatings bear the potential to reduce the risk of micromotion in modular taper junctions? Proc Inst Mech Eng H 2020; 234:897-908. [PMID: 32507037 DOI: 10.1177/0954411920930616] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Fretting corrosion is one contributor to the clinical failure of modular joint arthroplasty. It is initiated by micromotion in metal junctions exposed to fluids. Omitting metal-on-metal contacts could help to reduce the corrosion risk. The coating of one metal taper partner with a ceramic-based silicon nitride (SiNx) coating might provide this separation. The aim of the study was to identify whether a SiNx coating of the male taper component influences the micromotion within a taper junction. Hip prosthesis heads made of CoCr29Mo6 (Aesculap) and Ti6Al4V (Peter Brehm) were assembled (2000 N) to SiNx-coated and uncoated stem tapers made of Ti6Al4V and CoCr29Mo6 (2×2×2 combinations, each n = 4). Consecutive sinusoidal loading representing three daily activities was applied. Contactless relative motion in six degrees of freedom was measured using six eddy-current sensors. Micromotion in the junction was determined by compensating for the elastic deformation derived from additional monoblock measurements. After pull-off, the taper surfaces were microscopically inspected. Micromotion magnitude reached up to 8.4 ± 0.8 µm during loading that represented stumbling. Ti6Al4V stems showed significantly higher micromotion than those made of CoCr29Mo6, while taper coating had no influence. Statistical differences in pull-off forces were found for none of the taper junctions. Microscopy revealed CoCr29Mo6 abrasion from the head taper surface if combined with coated stem tapers. Higher micromotion of Ti6Al4V tapers was probably caused by the lower Young's modulus. Even in the contact areas, the coating was not damaged during loading. The mechanics of coated tapers was similar to uncoated prostheses. Thus, the separation of the two metal surfaces with the objective to reduce in vivo corrosion appears to be achievable if the coating is able to withstand in vivo conditions. However, the hard ceramic-based stem coating lead to undesirable debris from the CoCr29Mo6 heads during loading.
Collapse
Affiliation(s)
- Henning Haschke
- Institute of Biomechanics, Hamburg University of Technology (TUHH), Hamburg, Germany
| | - Adrian Falkenberg
- Institute of Biomechanics, Hamburg University of Technology (TUHH), Hamburg, Germany
| | - Michael M Morlock
- Institute of Biomechanics, Hamburg University of Technology (TUHH), Hamburg, Germany
| | - Gerd Huber
- Institute of Biomechanics, Hamburg University of Technology (TUHH), Hamburg, Germany
| |
Collapse
|
14
|
Xu J, Sonntag R, Kretzer JP, Taylor D, Forst R, Seehaus F. Model-Based Roentgen Stereophotogrammetric Analysis to Monitor the Head-Taper Junction in Total Hip Arthroplasty in Vivo-And They Do Move. MATERIALS 2020; 13:ma13071543. [PMID: 32230788 PMCID: PMC7178274 DOI: 10.3390/ma13071543] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 03/23/2020] [Accepted: 03/24/2020] [Indexed: 12/01/2022]
Abstract
Model-based Roentgen stereophotogrammetric analysis (RSA) using elementary geometrical shape (EGS) models allows migration measurement of implants without the necessity of additional attached implant markers. The aims of this study were: (i) to assess the possibility of measuring potential head–taper movement in THA in vivo using model-based RSA and (ii) to prove the validity of measured head–taper migration data in vitro and in vivo. From a previous RSA study with a 10 years follow-up, retrospectively for n = 45 patients head–taper migration was calculated as the relative migration between femoral ball head and taper of the femoral stem using model-based RSA. A head–taper migration of 0.026 mm/year can be detected with available RSA technology. In vitro validation showed a total migration of 268 ± 11 µm along the taper axis in a similar range to what has been reported using the RSA method. In vivo, a proof for interchangeable applicability of model-based RSA (EGS) and standard marker-based RSA methods was indicated by a significant deviation within the migration result after 12-month follow-up for all translation measurements, which was significantly correlated to the measured head–taper migration (r from 0.40 to 0.67; p < 0.05). The results identified that model-based RSA (EGS) could be used to detect head–taper migration in vivo and the measured movement could be validated in vitro and in vivo as well. Those findings supported the possibility of applying RSA for helping evaluate the head–taper corrosion related failure (trunnionosis).
Collapse
Affiliation(s)
- Jing Xu
- Department of Orthopaedic Surgery, Faculty of Medicine, University of Erlangen-Nürnberg, 91054 Erlangen, Germany
| | - Robert Sonntag
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, 69118 Heidelberg, Germany
| | - J. Philippe Kretzer
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, 69118 Heidelberg, Germany
| | - Dominic Taylor
- Department of Orthopaedic Surgery, Faculty of Medicine, University of Erlangen-Nürnberg, 91054 Erlangen, Germany
| | - Raimund Forst
- Department of Orthopaedic Surgery, Faculty of Medicine, University of Erlangen-Nürnberg, 91054 Erlangen, Germany
| | - Frank Seehaus
- Department of Orthopaedic Surgery, Faculty of Medicine, University of Erlangen-Nürnberg, 91054 Erlangen, Germany
- Correspondence:
| |
Collapse
|
15
|
Bechstedt M, Gustafson JA, Mell SP, Gührs J, Morlock MM, Levine BR, Lundberg HJ. Contact conditions for total hip head-neck modular taper junctions with microgrooved stem tapers. J Biomech 2020; 103:109689. [PMID: 32139099 DOI: 10.1016/j.jbiomech.2020.109689] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2019] [Revised: 02/21/2020] [Accepted: 02/23/2020] [Indexed: 10/24/2022]
Abstract
Implant failure due to fretting-corrosion of head-neck modular junctions is a rising problem in total hip arthroplasty. Fretting-corrosion initiates when micromotion leads to metal release; however, factors leading to micromotion, such as microgrooves on the stem taper, are not fully understood. The purpose of this study is to describe a finite element analysis technique to determine head-neck contact mechanics and investigate the effect of stem taper microgroove height during head-neck assembly. Two-dimensional axisymmetric finite element models were created. Models were created for a ceramic femoral head and a CoCrMo femoral head against Ti6Al4V stem tapers and compared to available data from prior experiments. Stem taper microgroove height was investigated with a generic 12/14 model. Head-neck assembly was performed to four maximum loads (500 N, 2000 N, 4000 N, 8000 N). For the stem taper coupled with the ceramic head, the number of microgrooves in contact and plastically deformed differed by 2.5 microgrooves (4%) and 6.5 microgrooves (11%), respectively, between the finite element models and experiment. For the stem taper coupled with the CoCrMo head, all microgrooves were in contact after all assembly loads in the finite element model due to an almost identical conical angle between the taper surfaces. In the experiments, all grooves were only in contact for the 8000 N assembly load. Contact area, plastic (permanent) deformation, and contact pressure increased with increasing assembly loads and deeper microgrooves. The described modeling technique can be used to investigate the relationship between implant design factors, allowing for optimal microgroove design within material couples.
Collapse
Affiliation(s)
- Maren Bechstedt
- Institute of Biomechanics, TUHH Hamburg University of Technology, 21073 Hamburg, Germany
| | - Jonathan A Gustafson
- Department of Orthopedic Surgery, Rush University Medical Center, 1611 W Harrison St Suite 201, Chicago, IL 60612, United States
| | - Steven P Mell
- Department of Orthopedic Surgery, Rush University Medical Center, 1611 W Harrison St Suite 201, Chicago, IL 60612, United States
| | - Julian Gührs
- Institute of Biomechanics, TUHH Hamburg University of Technology, 21073 Hamburg, Germany
| | - Michael M Morlock
- Institute of Biomechanics, TUHH Hamburg University of Technology, 21073 Hamburg, Germany
| | - Brett R Levine
- Department of Orthopedic Surgery, Rush University Medical Center, 1611 W Harrison St Suite 201, Chicago, IL 60612, United States
| | - Hannah J Lundberg
- Department of Orthopedic Surgery, Rush University Medical Center, 1611 W Harrison St Suite 201, Chicago, IL 60612, United States.
| |
Collapse
|
16
|
The Influence of Assembly Force on the Material Loss at the Metallic Head-Neck Junction of Hip Implants Subjected to Cyclic Fretting Wear. METALS 2019. [DOI: 10.3390/met9040422] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The impaction force required to assemble the head and stem components of hip implants is proven to play a major role in the mechanics of the taper junction. However, it is not clear if the assembly force could have an effect on fretting wear, which normally occurs at the junction. In this study, an adaptive finite element model was developed for a CoCr/CoCr head-neck junction with an angular mismatch of 0.01° in order to simulate the fretting wear process and predict the material loss under various assembly forces and over a high number of gait cycles. The junction was assembled with 2, 3, 4, and 5 kN and then subjected to 1,025,000 cycles of normal walking gait loading. The findings showed that material removal due to fretting wear increased when raising the assembly force. High assembly forces induced greater contact pressures over larger contact regions at the interface, which, in turn, resulted in more material loss and wear damage to the surface when compared to lower assembly forces. Although a high assembly force (greater than 4 kN) can further improve the initial strength and stability of the taper junction, it appears that it also increases the degree of fretting wear. Further studies are needed to investigate the assembly force in the other taper designs, angular mismatches, and material combinations.
Collapse
|
17
|
Sultan AA, Cantrell WA, Khlopas A, Berger RJ, Sodhi N, Molloy RM, Krebs VE, Mont MA. Evidence-Based Management of Trunnionosis in Metal-on-Polyethylene Total Hip Arthroplasty: A Systematic Review. J Arthroplasty 2018; 33:3343-3353. [PMID: 29929829 DOI: 10.1016/j.arth.2018.05.035] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2018] [Revised: 05/21/2018] [Accepted: 05/23/2018] [Indexed: 02/01/2023] Open
Abstract
Multiple recent reports have indicated a rising awareness of trunnionosis-related implant failures, accounting for up to 3% of all total hip arthroplasty revisions. Moreover, aseptic loosening and osteolysis from local release of metal debris can be the presenting manifestations, and thus the true incidence of trunnionosis is thought to be underreported. Furthermore, the relatively unclear and multifactorial pathogenesis and the widely variable clinical presentations pose a diagnostic challenge. A consensus regarding the ideal intervention and its timing is also lacking. Because of the relative paucity of reports regarding the diagnosis and management of trunnionosis, we conducted this evidence-based review to evaluate the (1) incidence, (2) pathogenesis, (3) diagnosis, and (4) treatment of trunnionosis in metal-on-polyethylene total hip arthroplasty. We then propose an algorithm for the diagnostic work-up and management of this condition.
Collapse
Affiliation(s)
- Assem A Sultan
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| | | | - Anton Khlopas
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| | - Ryan J Berger
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| | - Nipun Sodhi
- Department of Orthopaedic Surgery, Lenox Hill Hospital, New York City, NY
| | - Robert M Molloy
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| | - Viktor E Krebs
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| | - Michael A Mont
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH; Department of Orthopaedic Surgery, Lenox Hill Hospital, New York City, NY
| |
Collapse
|
18
|
Raji HY, Shelton JC. Prediction of taper performance using quasi static FE models: The influence of loading, taper clearance and trunnion length. J Biomed Mater Res B Appl Biomater 2018; 107:138-148. [DOI: 10.1002/jbm.b.34104] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2017] [Revised: 01/19/2018] [Accepted: 02/18/2018] [Indexed: 11/10/2022]
Affiliation(s)
- Halimat Y. Raji
- School of Engineering and Materials Science; Queen Mary University of London; London E1 4NS UK
| | - Julia C. Shelton
- School of Engineering and Materials Science; Queen Mary University of London; London E1 4NS UK
| |
Collapse
|
19
|
Berstock JR, Whitehouse MR, Duncan CP. Trunnion corrosion: what surgeons need to know in 2018. Bone Joint J 2018; 100-B:44-49. [PMID: 29292339 PMCID: PMC6424439 DOI: 10.1302/0301-620x.100b1.bjj-2017-0569.r1] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/08/2017] [Accepted: 06/19/2017] [Indexed: 11/05/2022]
Abstract
AIMS To present a surgically relevant update of trunnionosis. MATERIALS AND METHODS Systematic review performed April 2017. RESULTS Trunnionosis accounts for approximately 2% of the revision total hip arthroplasty (THA) burden. Thinner (reduced flexural rigidity) and shorter trunnions (reduced contact area at the taper junction) may contribute to mechanically assisted corrosion, exacerbated by high offset implants. The contribution of large heads and mixed metallurgy is discussed. CONCLUSION Identifying causative risk factors is challenging due to the multifactorial nature of this problem. Cite this article: Bone Joint J 2018;100-B(1 Supple A):44-9.
Collapse
Affiliation(s)
- J R Berstock
- Musculoskeletal Research Unit, Bristol Medical School, 1st Floor Learning & Research Building, Southmead Hospital, Bristol BS10 5NB, UK
| | - M R Whitehouse
- Musculoskeletal Research Unit, Bristol Medical School, 1st Floor Learning & Research Building, Southmead Hospital, Bristol BS10 5NB, UK
| | - C P Duncan
- Vancouver General Hospital, University of British Columbia, JP North 3rd floor, Room 3114, 910 West 10th Avenue, Vancouver, BC V5Z 4E3, Canada
| |
Collapse
|
20
|
Affiliation(s)
- Mitchell C Weiser
- 1Department of Orthopaedic Surgery, New York University Langone Medical Center, Hospital for Joint Diseases, and Insall Scott Kelly Institute for Orthopaedics and Sports Medicine, New York, NY 2Department of Orthopedics & Rehabilitation, University of Miami, Coral Gables, Florida 3Department of Mechanical and Materials Engineering and Department of Physical Therapy, Florida International University, Coral Gables, Florida
| | | |
Collapse
|
21
|
Whittaker RK, Hothi HS, Eskelinen A, Blunn GW, Skinner JA, Hart AJ. Variation in taper surface roughness for a single design effects the wear rate in total hip arthroplasty. J Orthop Res 2017; 35:1784-1792. [PMID: 27704611 DOI: 10.1002/jor.23456] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2016] [Accepted: 09/29/2016] [Indexed: 02/04/2023]
Abstract
Material loss from the head-stem taper junction of total hip arthroplasty (THA) is implicated in adverse reactions to metal debris (ARMD); the mechanisms for this are multi-factorial. We investigated the relationship between the roughness of the "as manufactured" taper surface and the wear rate from this junction. Fifty retrieved Pinnacle metal-on-metal (MOM) bearings paired with a Corail stem were included in the study. Multivariable statistical analysis was performed to determine the influence of taper roughness on material loss rate after controlling for other confounding surgical, implant, and patient factors. The surface roughness of the "as manufactured" head taper surface was associated with the rate of material loss from this surface. Four of eighteen roughness variables taken from ISO 4,287 and ISO 13,565-2 were significant: The Reduced Peak Height (Rpk, the protruding peaks above the core) (p = 0.004), Material Ratio 1 (Mr1, the ratio of the protruding peaks above the core) (p = 0.002), Area of the Peak Region (A1, the area of the Abbott-Curve that contains the peaks from the profile) (p = 0.003) and the Skewness (Rsk, the asymmetry of the height distribution corresponding to the height or depth of surface features) (p = 0.03). We found a large variability in the measured values with a median (range) of 0.50 (0.05-2.98), 11.98 (0.46-39.98), 30.89 (0.15-581.00), and 0.04 (-0.73-0.84), respectively. A 1-unit increase in Rpk was associated with a 73% increase in the taper wear rate. The variability of "as manufactured" surface roughness has a significant effect on taper material loss. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1784-1792, 2017.
Collapse
Affiliation(s)
- Robert K Whittaker
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, London, HA7 4LP, United Kingdom
| | - Harry S Hothi
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, London, HA7 4LP, United Kingdom
| | | | - Gordon W Blunn
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, London, HA7 4LP, United Kingdom
| | - John A Skinner
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, London, HA7 4LP, United Kingdom
| | - Alister J Hart
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, London, HA7 4LP, United Kingdom
| |
Collapse
|
22
|
|
23
|
Surface and subsurface changes as a result of tribocorrosion at the stem-neck interface of bi-modular prosthesis. ACTA ACUST UNITED AC 2017. [DOI: 10.1016/j.biotri.2017.02.002] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
24
|
Morlock M, Bünte D, Gührs J, Bishop N. Corrosion of the Head-Stem Taper Junction-Are We on the Verge of an Epidemic?: Review Article. HSS J 2017; 13:42-49. [PMID: 28167873 PMCID: PMC5264576 DOI: 10.1007/s11420-016-9526-4] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2016] [Accepted: 08/29/2016] [Indexed: 02/07/2023]
Abstract
BACKGROUND The modular head taper junction has contributed to the success of total hip arthroplasty (THA) greatly. Taper corrosion and wear problems reported for large and extra-large metal-on-metal bearings as well as for bi-modular THA stems have cast doubt on the benefit of the taper interface. Presently, corrosion problems are being reported for nearly all kinds of artificial hip joints incorporating metal heads, questioning taper connections in general. QUESTIONS/PURPOSES This study aimed to review the mechanical and electrochemical relationships that may lead to taper corrosion, which have been reported more commonly in recent literature, and to also review the contribution of patient characteristics and surgical techniques involved in taper assembly that may contribute to the problem. METHODS The search criteria "(corrosion) AND (hip arthroplasty) AND (taper OR trunnion)" and "(hip arthroplasty) AND ((pseudotumor) OR (pseudo-tumor))" in PubMed and the JAAOS were used for the literature search. In addition, the arthroplasty registers were considered. RESULTS Most studies acknowledge the multifactorial nature of the problem but concentrate their analysis on taper and implant design aspects, since this is the only factor that can be easily quantified. The sometimes conflicting results in the literature could be due to the fact that the other two decisive factors are not sufficiently considered: the loading situation in the patient and the assembly situation by the surgeon. All three factors together determine the fate of a taper junction in THA. There is no single reason as a main cause for taper corrosion. The combined "outcome" of these three factors has to be in a "safe range" to achieve a successful long-term taper fixation. CONCLUSION No, this is not the beginning of an epidemic. It is rather the consequence of disregarding known mechanical and electrochemical relationships, which in combination have recently caused a more frequent occurrence-and mainly reporting-of corrosion issues.
Collapse
Affiliation(s)
- Michael Morlock
- Institute of Biomechanics, TUHH Hamburg University of Technology, Denickestrasse 15, 21073 Hamburg, Germany
| | - Dennis Bünte
- Institute of Biomechanics, TUHH Hamburg University of Technology, Denickestrasse 15, 21073 Hamburg, Germany
| | - Julian Gührs
- Institute of Biomechanics, TUHH Hamburg University of Technology, Denickestrasse 15, 21073 Hamburg, Germany
| | - Nicholas Bishop
- Institute of Biomechanics, TUHH Hamburg University of Technology, Denickestrasse 15, 21073 Hamburg, Germany
| |
Collapse
|
25
|
|
26
|
Jauch-Matt SY, Miles AW, Gill HS. Effect of trunnion roughness and length on the modular taper junction strength under typical intraoperative assembly forces. Med Eng Phys 2016; 39:94-101. [PMID: 27913177 DOI: 10.1016/j.medengphy.2016.11.001] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2016] [Revised: 10/15/2016] [Accepted: 11/13/2016] [Indexed: 01/24/2023]
Abstract
Modular hip implants are at risk of fretting-induced postoperative complications most likely initiated by micromotion between adjacent implant components. A stable fixation between ball head and stem-neck taper is critical to avoid excessive interface motions. Therefore, the aim of this study was to identify the effect of trunnion roughness and length on the modular taper strength under typical intraoperative assembly forces. Custom-made Titanium trunnions (standard/mini taper, smooth/grooved surface finish) were assembled with modular Cobalt-chromium heads by impaction with peak forces ranging from 2kN to 6kN. After each assembly process these were disassembled with a materials testing machine to detect the pull-off force as a measure for the taper strength. As expected, the pull-off forces increased with rising peak assembly force (p < 0.001). For low and moderate assembly forces, smooth standard tapers offered higher pull-off forces compared to grooved tapers (p < 0.038). In the case of an assembly force of 2kN, mini tapers showed a higher taper strength than standard ones (p=0.037). The results of this study showed that smooth tapers provided a higher strength for taper junctions. This higher taper strength may reduce the risk of fretting-related complications especially in the most common range of intraoperative assembly forces.
Collapse
Affiliation(s)
- S Y Jauch-Matt
- Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, United Kingdom.
| | - A W Miles
- Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, United Kingdom.
| | - H S Gill
- Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, United Kingdom.
| |
Collapse
|
27
|
Pourzal R, Hall DJ, Ha NQ, Urban RM, Levine BR, Jacobs JJ, Lundberg HJ. Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions? Clin Orthop Relat Res 2016; 474:2232-42. [PMID: 27339123 PMCID: PMC5014821 DOI: 10.1007/s11999-016-4933-x] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND There are increasing reports of total hip arthroplasty failure subsequent to modular taper junction corrosion. The surfaces of tapers are machined to have circumferential machining marks, resulting in a surface topography of alternating peaks and valleys on the scale of micrometers. It is unclear if the geometry of this machined surface topography influences the degree of fretting and corrosion damage present on modular taper junctions or if there are differences between modular taper junction material couples. QUESTIONS/PURPOSES (1) What are the differences in damage score and surface topography between CoCr/CoCr and CoCr/Ti modular junctions? (2) How are initial surface topography, flexural rigidity, taper angle mismatch, and time in situ related to visual taper damage scores for CoCr/CoCr couples? (3) How are initial surface topography, flexural rigidity, taper angle mismatch, and time in situ related to visual taper damage scores for CoCr/Ti couples? METHODS Damage on stem and head tapers was evaluated with a modified Goldberg score. Differences in damage scores were determined between a group of 140 CoCr/CoCr couples and 129 CoCr/Ti couples using a chi-square test. For a subgroup of 70 retrievals, selected at random, we measured five variables, including initial stem taper machining mark height and spacing, initial head taper roughness, flexural rigidity, and taper angle mismatch. All retrievals were obtained at revision surgeries. None were retrieved as a result of metal-on-metal failures or were recalled implants. Components were chosen so there was a comparable number of each material couple and damage score. Machining marks around the circumference of the tapers were measured using white light interferometry to characterize the initial stem taper surface topography in terms of the height of and spacing between machining mark peaks as well as initial head taper roughness. The taper angle mismatch was assessed with a coordinate measuring machine. Flexural rigidity was determined based on measurements of gross taper dimensions and material properties. Differences of median or mean values of all variables between material couples were determined (Wilcoxon rank-sum tests and t-tests). The effect of all five variables along with time in situ on stem and head taper damage scores was tested with a multiple regression model. With 70 retrievals, a statistical power of 0.8 could be achieved for the model. RESULTS Damage scores were different between CoCr/CoCr and CoCr/Ti modular taper junction material couples. CoCr/CoCr stem tapers were less likely to be mildly damaged (11%, p = 0.006) but more likely to be severely damaged (4%, p = 0.02) than CoCr/Ti stem tapers (28% and 1%, respectively). CoCr/CoCr couples were less likely to have moderately worn head tapers (7% versus 17%, p = 0.003). Stem taper machining mark height and spacing and head taper roughness were 11 (SD 3), 185 (SD 46), and 0.57 (SD 0.5) for CoCr/CoCr couples and 10 (SD 3), 170 (SD 56), and 0.64 (SD 0.4) for CoCr/Ti couples, respectively. There was no difference (p = 0.09, p = 0.1, p = 0.16, respectively) for either factor between material couples. Larger stem taper machining mark heights (p = 0.001) were associated with lower stem taper damage scores, and time in situ (p = 0.006) was associated with higher stem taper damage scores for CoCr/CoCr material couples. Stem taper machining marks that had higher peaks resulted in slower damage progression over time. For CoCr/Ti material couples, head taper roughness was associated with higher stem (p = 0.001) and head taper (p = 0.003) damage scores, and stem taper machining mark height, but not time in situ, was associated with lower stem taper damage scores (p = 0.007). CONCLUSIONS Stem taper surface topography was related to damage scores on retrieved head-neck modular junctions; however, it affected CoCr/CoCr and CoCr/Ti couples differently. CLINICAL RELEVANCE A taper topography of circumferential machining marks with higher peaks appears to enable slower damage progression and, subsequently, a reduction of the reported release of corrosion products. This may be of interest to implant designers and manufacturers in an effort to reduce the effects of metal release from modular femoral components.
Collapse
Affiliation(s)
- Robin Pourzal
- Department of Orthopedic Surgery, Rush University Medical Center, 1611W Harrison Street, Suite 200, Chicago, IL 60612 USA
| | - Deborah J. Hall
- Department of Orthopedic Surgery, Rush University Medical Center, 1611W Harrison Street, Suite 200, Chicago, IL 60612 USA
| | - Nguyen Q. Ha
- Department of Orthopedic Surgery, Rush University Medical Center, 1611W Harrison Street, Suite 200, Chicago, IL 60612 USA
| | - Robert M. Urban
- Department of Orthopedic Surgery, Rush University Medical Center, 1611W Harrison Street, Suite 200, Chicago, IL 60612 USA
| | - Brett R. Levine
- Department of Orthopedic Surgery, Rush University Medical Center, 1611W Harrison Street, Suite 200, Chicago, IL 60612 USA
| | - Joshua J. Jacobs
- Department of Orthopedic Surgery, Rush University Medical Center, 1611W Harrison Street, Suite 200, Chicago, IL 60612 USA
| | - Hannah J. Lundberg
- Department of Orthopedic Surgery, Rush University Medical Center, 1611W Harrison Street, Suite 200, Chicago, IL 60612 USA
| |
Collapse
|
28
|
MacLeod AR, Sullivan NPT, Whitehouse MR, Gill HS. Large-diameter total hip arthroplasty modular heads require greater assembly forces for initial stability. Bone Joint Res 2016; 5:338-46. [PMID: 27496914 PMCID: PMC5013896 DOI: 10.1302/2046-3758.58.bjr-2016-0044.r1] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2016] [Accepted: 05/06/2016] [Indexed: 11/22/2022] Open
Abstract
Objectives Modular junctions are ubiquitous in contemporary hip arthroplasty. The head-trunnion junction is implicated in the failure of large diameter metal-on-metal (MoM) hips which are the currently the topic of one the largest legal actions in the history of orthopaedics (estimated costs are stated to exceed $4 billion). Several factors are known to influence the strength of these press-fit modular connections. However, the influence of different head sizes has not previously been investigated. The aim of the study was to establish whether the choice of head size influences the initial strength of the trunnion-head connection. Materials and Methods Ti-6Al-4V trunnions (n = 60) and two different sizes of cobalt-chromium (Co-Cr) heads (28 mm and 36 mm; 30 of each size) were used in the study. Three different levels of assembly force were considered: 4 kN; 5 kN; and 6 kN (n = 10 each). The strength of the press-fit connection was subsequently evaluated by measuring the pull-off force required to break the connection. The statistical differences in pull-off force were examined using a Kruskal–Wallis test and two-sample Mann–Whitney U test. Finite element and analytical models were developed to understand the reasons for the experimentally observed differences. Results 36 mm diameter heads had significantly lower pull-off forces than 28 mm heads when impacted at 4 kN and 5 kN (p < 0.001; p < 0.001), but not at 6 kN (p = 0.21). Mean pull-off forces at 4 kN and 5 kN impaction forces were approximately 20% larger for 28 mm heads compared with 36 mm heads. Finite element and analytical models demonstrate that the differences in pull-off strength can be explained by differences in structural rigidity and the resulting interface pressures. Conclusion This is the first study to show that 36 mm Co-Cr heads have up to 20% lower pull-off connection strength compared with 28 mm heads for equivalent assembly forces. This effect is likely to play a role in the high failure rates of large diameter MoM hips. Cite this article: A. R. MacLeod, N. P. T. Sullivan, M. R. Whitehouse, H. S. Gill. Large-diameter total hip arthroplasty modular heads require greater assembly forces for initial stability. Bone Joint Res 2016;5:338–346. DOI: 10.1302/2046-3758.58.BJR-2016-0044.R1.
Collapse
Affiliation(s)
- A R MacLeod
- University of Bath, Claverton Down Rd, Bath, North East Somerset BA2 7AY, UK
| | - N P T Sullivan
- Southmead Hospital, Department of Trauma and Orthopaedics, North Bristol NHS Trust, Southmead Way, Bristol, BS10 5NB, UK
| | - M R Whitehouse
- University of Bristol, Musculoskeletal Research Unit, Southmead Hospital, Bristol, UK, BS10 5NB, UK
| | - H S Gill
- University of Bath, Claverton Down Rd, Bath, North East Somerset BA2 7AY, UK
| |
Collapse
|