1
|
Cheng Y, Pang SW. Biointerfaces with ultrathin patterns for directional control of cell migration. J Nanobiotechnology 2024; 22:158. [PMID: 38589901 PMCID: PMC11000378 DOI: 10.1186/s12951-024-02418-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Accepted: 03/18/2024] [Indexed: 04/10/2024] Open
Abstract
In the context of wound healing and tissue regeneration, precise control of cell migration direction is deemed crucial. To address this challenge, polydimethylsiloxane (PDMS) platforms with patterned 10 nm thick TiOx in arrowhead shape were designed and fabricated. Remarkably, without tall sidewall constraints, MC3T3-E1 cells seeded on these platforms were constrained to migrate along the tips of the arrowheads, as the cells were guided by the asymmetrical arrowhead tips which provided large contact areas. To the best of our knowledge, this is the first study demonstrating the use of thin TiOx arrowhead pattern in combination with a cell-repellent PDMS surface to provide guided cell migration unidirectionally without tall sidewall constraints. Additionally, high-resolution fluorescence imaging revealed that the asymmetrical distribution of focal adhesions, triggered by the patterned TiOx arrowheads with arm lengths of 10, 20, and 35 μm, promoted cell adhesion and protrusion along the arrowhead tip direction, resulting in unidirectional cell migration. These findings have important implications for the design of biointerfaces with ultrathin patterns to precisely control cell migration. Furthermore, microelectrodes were integrated with the patterned TiOx arrowheads to enable dynamic monitoring of cell migration using impedance measurement. This microfluidic device integrated with thin layer of guiding pattern and microelectrodes allows simultaneous control of directional cell migration and characterization of the cell movement of individual MC3T3-E1 cells, offering great potential for the development of biosensors for single-cell monitoring.
Collapse
Grants
- CityU11207620, CityU11207821, CityU11205423 Research Grants Council of the Hong Kong Special Administrative Region, China
- CityU11207620, CityU11207821, CityU11205423 Research Grants Council of the Hong Kong Special Administrative Region, China
- 9360148, 9380062 Center for Biosystems, Neuroscience, and Nanotechnology (CBNN) of City University of Hong Kong
- 9360148, 9380062 Center for Biosystems, Neuroscience, and Nanotechnology (CBNN) of City University of Hong Kong
Collapse
Affiliation(s)
- Yijun Cheng
- Department of Electrical Engineering, City University of Hong Kong, Kowloon, Hong Kong, China
- Centre for Biosystems, Neuroscience, and Nanotechnology, City University of Hong Kong, Kowloon, Hong Kong, China
| | - Stella W Pang
- Department of Electrical Engineering, City University of Hong Kong, Kowloon, Hong Kong, China.
- Centre for Biosystems, Neuroscience, and Nanotechnology, City University of Hong Kong, Kowloon, Hong Kong, China.
| |
Collapse
|
2
|
Cheng Y, Pang SW. Effects of nanopillars and surface coating on dynamic traction force. MICROSYSTEMS & NANOENGINEERING 2023; 9:6. [PMID: 36620393 PMCID: PMC9814462 DOI: 10.1038/s41378-022-00473-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/17/2022] [Revised: 10/11/2022] [Accepted: 11/04/2022] [Indexed: 06/17/2023]
Abstract
The extracellular matrix serves as structural support for cells and provides biophysical and biochemical cues for cell migration. Topography, material, and surface energy can regulate cell migration behaviors. Here, the responses of MC3T3-E1 cells, including migration speed, morphology, and spreading on various platform surfaces, were investigated. Polydimethylsiloxane (PDMS) micropost sensing platforms with nanopillars, silicon oxide, and titanium oxide on top of the microposts were fabricated, and the dynamic cell traction force during migration was monitored. The relationships between various platform surfaces, migration behaviors, and cell traction forces were studied. Compared with the flat PDMS surface, cells on silicon oxide and titanium oxide surfaces showed reduced mobility and less elongation. On the other hand, cells on the nanopillar surface showed more elongation and a higher migration speed than cells on silicon oxide and titanium oxide surfaces. MC3T3-E1 cells on microposts with nanopillars exerted a larger traction force than those on flat PDMS microposts and had more filopodia and long protrusions. Understanding the relationships between platform surface condition, migration behavior, and cell traction force can potentially lead to better control of cell migration in biomaterials capable of promoting tissue repair and regeneration.
Collapse
Affiliation(s)
- Yijun Cheng
- Department of Electrical Engineering, City University of Hong Kong, Kowloon, Hong Kong, China
- Centre for Biosystems, Neuroscience, and Nanotechnology, City University of Hong Kong, Kowloon, Hong Kong, China
| | - Stella W. Pang
- Department of Electrical Engineering, City University of Hong Kong, Kowloon, Hong Kong, China
- Centre for Biosystems, Neuroscience, and Nanotechnology, City University of Hong Kong, Kowloon, Hong Kong, China
| |
Collapse
|
3
|
Engineered barriers regulate osteoblast cell migration in vertical direction. Sci Rep 2022; 12:4459. [PMID: 35292702 PMCID: PMC8924172 DOI: 10.1038/s41598-022-08262-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Accepted: 03/01/2022] [Indexed: 11/29/2022] Open
Abstract
Considering cell migration is essential for understanding physiological processes and diseases. The vertical migration of cells in three dimensions is vital, but most previous studies on cell migration have only focused on two-dimensional horizontal migration. In this paper, cell migration in the vertical direction was studied. Barriers with a height of 1, 5, 10, and 25 µm with grating and arrows in channels as guiding patterns were fabricated. The effects of barrier height and guiding patterns on the vertical migration of MC3T3 cells were explored. The study revealed that taller barriers hinder vertical migration of MC3T3 cells, whereas grating and arrows in channels promote it. The time-lapse and micrograph images showed that as the barrier height increased, the cell climbing angle along the barrier sidewall decreased, and the time taken to climb over the barrier increased. These results indicate that taller barriers increase the difficulty of vertical migration by MC3T3 cells. To promote the vertical migration of MC3T3 cells, 10 µm tall barriers with 18° and 40° sloped sidewalls were fabricated. For barriers with 18° sloped sidewalls, the probability for MC3T3 cells to climb up and down the 10 µm tall barriers was 40.6% and 20.3%, respectively; this is much higher than the migration probability over vertical barriers. This study shows topographic guidance on the vertical migration of MC3T3 cells and broadens the understanding of cell migration in the vertical direction.
Collapse
|
4
|
Cheng Y, Zhu S, Pang SW. Directing osteoblastic cell migration on arrays of nanopillars and nanoholes with different aspect ratios. LAB ON A CHIP 2021; 21:2206-2216. [PMID: 33876172 DOI: 10.1039/d1lc00104c] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
To realize highly directional guidance for cell migration, both micro- and nano-scale topographies were studied to better understand and mimic the complex extracellular matrix environment. Polydimethylsiloxane-based platforms with micro- and nano-topographies were developed to systematically study their guidance effects on cell migration behaviors. Compared to microtopography such as flat surface or grating, nanotopographies such as nanoholes and nanopillars could promote the generation of filopodia and extension of long protrusions with increased migration speed for MC3T3-E1 cells. Although cells on the grating structures showed lower migration speed, more directional cell migration was achieved due to their anisotropic topography compared to nanohole or nanopillar arrays with isotropic structures. To further enhance the cell migration directionality, the nanotopographies were patterned in grating arrangements and the results showed that both nanoholes and nanopillars in grating arrangements introduced more directional cell migration compared to gratings. The effects of physical dimensions of the nanotopographies on cell migration were studied and the results showed that there was less cell elongation and less directional migration of the nanoholes in grating arrangements with increasing depth of nanoholes. However, the nanopillars in grating arrangements showed more cell elongation, more directional migration, and higher migration speed with increasing height of the nanopillars. Platforms with nanopillars in grating arrangements and large height could be used to control cell migration speed and directionality, which could potentially lead to cell sorting and screening.
Collapse
Affiliation(s)
- Yijun Cheng
- Department of Electrical Engineering, Centre for Biosystems, Neuroscience, and Nanotechnology, City University of Hong Kong, Kowloon, Hong Kong, China.
| | - Shuyan Zhu
- Department of Electrical Engineering, Centre for Biosystems, Neuroscience, and Nanotechnology, City University of Hong Kong, Kowloon, Hong Kong, China.
| | - Stella W Pang
- Department of Electrical Engineering, Centre for Biosystems, Neuroscience, and Nanotechnology, City University of Hong Kong, Kowloon, Hong Kong, China.
| |
Collapse
|
5
|
Migration of immortalized nasopharyngeal epithelia and carcinoma cells through porous membrane in 3D platforms. Biosci Rep 2021; 40:224916. [PMID: 32440676 PMCID: PMC7273909 DOI: 10.1042/bsr20194113] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Revised: 05/15/2020] [Accepted: 05/20/2020] [Indexed: 12/16/2022] Open
Abstract
In the present study, 3D biomimetic platforms were fabricated with guiding grating to mimic extracellular matrix topography, porous membrane to resemble the epithelial porous interface and trenches below to represent blood vessels as an in vitro tissue microenvironment. Fabrication technologies were developed to integrate the transparent biocompatible polydimethylsiloxane platforms with preciously controlled dimensions. Cell migration behaviors of an immortalized nasopharyngeal epithelial cell line (NP460) and a nasopharyngeal carcinoma cell line (NPC43) were studied on the 2D and 3D platforms. The NP460 and NPC43 cells traversing through the porous membrane and migrating in the trenches below were studied by time-lapse imaging. Before traversing through the pores, NP460 and NPC43 cells migrated around the pores but NPC43 cells had a lower migration speed with less lamellipodia spreading. After traversing to trenches below, NPC43 cells moved faster with an alternated elongated morphology (mesenchymal migration mode) and round morphology (amoeboid migration mode) compared with only mesenchymal migration mode for NP460 cells. The cell traversing probability through porous membrane on platforms with 30 μm wide trenches below was found to be the highest when the guiding grating was perpendicular to the trenches below and the lowest when the guiding grating was parallel to the trenches below. The present study shows important information on cell migration in complex 3D microenvironment with various dimensions and could provide insight for pathology and treatment of nasopharyngeal carcinoma.
Collapse
|
6
|
Zhang WG, Liu ZY, Pang SW. Separation of nasopharyngeal epithelial cells from carcinoma cells on 3D scaffold platforms. Biotechnol Bioeng 2020; 118:1444-1455. [PMID: 33241857 DOI: 10.1002/bit.27640] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2020] [Revised: 10/27/2020] [Accepted: 11/21/2020] [Indexed: 12/27/2022]
Abstract
Scaffold microstructures were developed to mimic a three-dimensional extracellular matrix in studying cell migration and invasion. The multiple-layer scaffold platforms were designed to investigate cell migration and separation from top to bottom layer. Two cell lines including immortalized nasopharyngeal epithelial (NP460) cells and nasopharyngeal carcinoma (NPC43) cells with Epstein-Barr virus were compared in this study. On one-layer platforms with trench depth of 15 µm, both NP460 and NPC43 cells were guided to migrate along the 18-µm-wide trenches, and exhibited random migration directions when the trench width was 10 or 50 µm. Nearly no cell was found to migrate in the 10-µm-wide trenches on one-layer platforms. However, the NP460 and NPC43 cells showed very different probability in the narrow trenches on two-layer platforms, making it possible to separate the nasopharyngeal epithelial cells from the carcinoma cells. Moreover, 1-µm deep grating topography on the top layer inhibited NP460 cells to migrate from top ridges to the 10-µm-wide trenches, but promoted such behavior for NPC43 cells. The results demonstrated in This study suggest that the engineered multiple-layer scaffold platforms could be used to separate carcinoma cells in NPC tumor as a potential treatment of NPC.
Collapse
Affiliation(s)
- W G Zhang
- Department of Electrical Engineering, City University of Hong Kong, Hong Kong.,Centre for Biosystems, Neuroscience, and Nanotechnology, City University of Hong Kong, Hong Kong
| | - Z Y Liu
- Department of Electrical Engineering, City University of Hong Kong, Hong Kong.,Centre for Biosystems, Neuroscience, and Nanotechnology, City University of Hong Kong, Hong Kong
| | - S W Pang
- Department of Electrical Engineering, City University of Hong Kong, Hong Kong.,Centre for Biosystems, Neuroscience, and Nanotechnology, City University of Hong Kong, Hong Kong
| |
Collapse
|
7
|
Refaaq FM, Chen X, Pang SW. Effects of topographical guidance cues on osteoblast cell migration. Sci Rep 2020; 10:20003. [PMID: 33203986 PMCID: PMC7672072 DOI: 10.1038/s41598-020-77103-0] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Accepted: 11/05/2020] [Indexed: 12/13/2022] Open
Abstract
Cell migration is a fundamental process that is crucial for many biological functions in the body such as immune responses and tissue regeneration. Dysregulation of this process is associated with cancer metastasis. In this study, polydimethylsiloxane platforms with various topographical features were engineered to explore the influence of guiding patterns on MC3T3-E1 osteoblast cell migration. Focusing on the guiding effects of grating patterns, variations such as etch depth, pattern discontinuity, and bending angles were investigated. In all experiments, MC3T3-E1 cells on patterned surfaces demonstrated a higher migration speed and alignment when compared to flat surfaces. The study revealed that an increase in etch depth from 150 nm to 4.5 μm enhanced cell alignment and elongation along the grating patterns. In the presence of discontinuous elements, cell migration speed was accelerated when compared to gratings of the same etch depth. These results indicated that cell directionality preference was influenced by a high level of pattern discontinuity. On patterns with bends, cells were more inclined to reverse on 45° bends, with 69% of cells reversing at least once, compared to 54% on 135° bends. These results are attributed to cell morphology and motility mechanisms that are associated with surface topography, where actin filament structures such as filopodia and lamellipodia are essential in sensing the surrounding environment and controlling cell displacement. Knowledge of geometric guidance cues could provide a better understanding on how cell migration is influenced by extracellular matrix topography in vivo.
Collapse
Affiliation(s)
- F M Refaaq
- Department of Electrical Engineering, Centre for Biosystems, Neuroscience, and Nanotechnology, City University of Hong Kong, Kowloon, Hong Kong, China
| | - X Chen
- Department of Electrical Engineering, Centre for Biosystems, Neuroscience, and Nanotechnology, City University of Hong Kong, Kowloon, Hong Kong, China
| | - S W Pang
- Department of Electrical Engineering, Centre for Biosystems, Neuroscience, and Nanotechnology, City University of Hong Kong, Kowloon, Hong Kong, China.
| |
Collapse
|
8
|
Liu ZY, Zhang WG, Pang SW. Traversing behavior of tumor cells in three-dimensional platforms with different topography. PLoS One 2020; 15:e0234482. [PMID: 32520967 PMCID: PMC7286507 DOI: 10.1371/journal.pone.0234482] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2019] [Accepted: 05/27/2020] [Indexed: 12/19/2022] Open
Abstract
Three-dimensional polydimethylsiloxane platforms were developed to mimic the extracellular matrix with blood vessels by having scaffolds with micropatterns, porous membrane and trenches. Precisely controlled physical dimensions, layouts, and topography as well as different surface chemical treatments were applied to study their influences on nasopharyngeal carcinoma cell (10-15 μm in diameter) migration in mimicked platforms over 15-hour of time-lapse imaging. By placing the pores at different distance from the edges of the trenches, pores with different trench sidewall exposures and effective sizes were generated. Pores right next to the trench sidewalls showed the highest cell traversing probability, most likely related to the larger surface contact area with cells along the sidewalls. Straight grating oriented perpendicular to trenches below the top layer increased cell traversing probability. Pore shape as well as pore size influenced the cell traversing probability and cells could not traverse through pores that were 6 μm or less in diameter, which is much smaller than the cell size. Trench depth of 15 μm could induce more cells to traverse through the porous membrane, while shallower trenches impeded cell traversing and longer time was needed for cells to traverse because 3 and 6 μm deep trenches were much smaller than cell size which required large cell deformation. Hydrophobic surface coating on the top layer and fibronectin in pores and trenches increased the cell traversing probability and reduced the pore size that cells could traverse from 8 to 6 μm, which indicated that cells could have larger deformation with certain surface coatings.
Collapse
Affiliation(s)
- Z. Y. Liu
- Department of Electrical Engineering, City University of Hong Kong, Hong Kong, China
- Center for Biosystems, Neuroscience, and Nanotechnology, City University of Hong Kong, Hong Kong, China
| | - W. G. Zhang
- Department of Electrical Engineering, City University of Hong Kong, Hong Kong, China
- Center for Biosystems, Neuroscience, and Nanotechnology, City University of Hong Kong, Hong Kong, China
| | - S. W. Pang
- Department of Electrical Engineering, City University of Hong Kong, Hong Kong, China
- Center for Biosystems, Neuroscience, and Nanotechnology, City University of Hong Kong, Hong Kong, China
- * E-mail:
| |
Collapse
|
9
|
Tsang C, Liu Z, Zhang W, You C, Jones G, Tsao S, Pang S. Integration of biochemical and topographic cues for the formation and spatial distribution of invadosomes in nasopharyngeal epithelial cells. Acta Biomater 2020; 101:168-182. [PMID: 31683015 DOI: 10.1016/j.actbio.2019.10.043] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2019] [Revised: 10/16/2019] [Accepted: 10/30/2019] [Indexed: 01/03/2023]
Abstract
Invadosomes are invasive protrusions generated by cells which can secrete matrix metalloproteinases for focal digestion of extracellular matrix. They also aid invasive cancer cells in their transmigration through vascular endothelium. However, how the physical and chemical cues in a three-dimensional (3D) system signal the spatial localization of invadosomes remains largely unknown. Here we study the topographic guidance of invadosome formation in invasive nasopharyngeal cells under the stimulation of an inflammatory cytokine, TGF-β1, using engineered gratings with different width and depth. We first report that TGF-β1 can act as an external signal to upregulate the formation of invadosomes with a random distribution on a plane 2D surface. When the cells were seeded on parallel 3D gratings of 5 µm width and 1 µm depth, most of the invadosomes aligned to the edges of the gratings, indicating a topographic cue to the control of invadosome localization. While the number of invadosomes per cell were not upregulated when the cells were seeded on 3D topography, guidance of invadosomes localization to edges is correlated with cell migration directionality on 1 µm deep gratings. Invadosomes preferentially form at edges when the cells move at a lower speed and are guided along narrow gratings. The invadosomes forming at 3D edges also have a longer half-life than those forming on a plane surface. These data suggest that there are integrated biochemical and 3D geometric cues underlying the spatial regulation of invasive structures so as to elicit efficient invasion or metastasis of cells. STATEMENT OF SIGNIFICANCE: Nasopharyngeal cells were integrated with the biological cues and matrix topography to govern the activity and spatial distribution of invadosomes. The biochemical induction of invadosome formation by TGF-β1 in nasopharyngeal cells was observed. When the cells were seeded on parallel 3D gratings, most of the invadosomes aligned to the edges of the gratings due to topographical induced invadosome localization. While the number of invadosomes per cell were not upregulated, guidance of invadosomes localization to edges is correlated with cell migration directionality on 1 µm deep gratings. Invadosomes preferentially form at edges with a higher stability when the cells are guided along narrow gratings. The integrated biochemical and 3D geometric cues could elicit efficient invasion or metastasis of cells.
Collapse
|
10
|
Control of neural probe shank flexibility by fluidic pressure in embedded microchannel using PDMS/PI hybrid substrate. PLoS One 2019; 14:e0220258. [PMID: 31339963 PMCID: PMC6655783 DOI: 10.1371/journal.pone.0220258] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Accepted: 07/11/2019] [Indexed: 11/19/2022] Open
Abstract
Implantable neural probes are widely used to record and stimulate neural activities. These probes should be stiff enough for insertion. However, it should also be flexible to minimize tissue damage after insertion. Therefore, having dynamic control of the neural probe shank flexibility will be useful. For the first time, we have successfully fabricated flexible neural probes with embedded microfluidic channels for dynamic control of neural probe stiffness by controlling fluidic pressure in the channels. The present hybrid neural probes consisted of polydimethylsiloxane (PDMS) and polyimide (PI) layers could provide the required stiffness for insertion and flexibility during operation. The PDMS channels were fabricated by reversal imprint using a silicon mold and bonded to a PI layer to form the embedded channels in the neural probe. The probe shape was patterned using an oxygen plasma generated by an inductively coupled plasma etching system. The critical buckling force of PDMS/PI neural probes could be tuned from 0.25-1.25 mN depending on the applied fluidic pressure in the microchannels and these probes were successfully inserted into a 0.6% agarose gel that mimicked the stiffness of the brain tissue. Polymer-based neural probes are typically more flexible than conventional metal wire-based probes, and they could potentially provide less tissue damage after implantation.
Collapse
|
11
|
Hui J, Pang S. Cell traction force in a confined microenvironment with double-sided micropost arrays. RSC Adv 2019; 9:8575-8584. [PMID: 35518671 PMCID: PMC9061871 DOI: 10.1039/c8ra10170a] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2018] [Accepted: 03/07/2019] [Indexed: 11/21/2022] Open
Abstract
Three-dimensional (3D) cell migrations are regulated by force interactions between cells and a 3D extracellular matrix (ECM). Mapping the 3D traction force generated by cells on the surrounding ECM with controlled confinement and contact area will be useful in understanding cell migration. In this study, double-sided micropost arrays were fabricated. The cell traction force was mapped by microposts on the top and bottom of opposing surfaces with a controlled separating distance to create different confinements. The density of micropost arrays was modified to investigate the effect of cell contact area on 3D traction force development. Using MC3T3-E1 osteoblastic cells, the leading traction force was found to increase with additional contact surface on the top. Summing force vectors on both surfaces, a large force imbalance was found from the leading to trailing regions for fast migrating cells. With 10 μm separation and densely arranged microposts, the traction force on the top surface was the largest at 28.6 ± 2.5 nN with the highest migration speed of 0.61 ± 0.07 μm min−1. Decreasing the density of the top micropost arrays resulted in a reduced traction force on the top and lower migration speed. With 15 μm separation, the cell traction force on the top and migration speed further decreased simultaneously. These results revealed traction force development on 3D ECM with varied degrees of confinement and contact area, which is important in regulating 3D cell migration. Double-sided micropost arrays to monitor three-dimensional cell traction force development over time on top and bottom surfaces with controlled confinement and contact area.![]()
Collapse
Affiliation(s)
- Jianan Hui
- Department of Electronic Engineering
- City University of Hong Kong
- China
- Center for Biosystems, Neuroscience, and Nanotechnology
- City University of Hong Kong
| | - Stella W. Pang
- Department of Electronic Engineering
- City University of Hong Kong
- China
- Center for Biosystems, Neuroscience, and Nanotechnology
- City University of Hong Kong
| |
Collapse
|
12
|
Hui J, Pang SW. Dynamic Tracking of Osteoblastic Cell Traction Force during Guided Migration. Cell Mol Bioeng 2017; 11:11-23. [PMID: 31719876 DOI: 10.1007/s12195-017-0514-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2017] [Accepted: 11/11/2017] [Indexed: 11/30/2022] Open
Abstract
Introduction Continuous development of cell traction force can regulate cell migration on various extracellular matrixes in vivo. However, the topographical effect on traction force is still not fully understood. Methods Micropost sensors with parallel guiding gratings were fabricated in polydimethylsiloxane to track the cell traction force during topographical guidance in real time. The force distributions along MC3T3-E1 mouse osteoblasts were captured every minute. The traction force in the leading, middle, and trailing regions was monitored during forward and reversed cell migration. Results The traction force showed periodic changes during cell migration when the cell changed from elongated to contracted shape. For cell migration without guiding pattern, the leading region showed the largest traction force among the three regions, typically 5.8 ± 0.8 nanonewton (nN) when the cell contracted and 7.1 ± 0.5 nN when it elongated. During guided cell migration, a lower traction force was obtained. When a cell contracted, the trailing traction force was 4.1 ± 0.4 for non-guided migration and 2.2 ± 0.2 nN for guided migration. As a cell became elongated, the trailing traction force was 6.0 ± 0.5 nN during non-guided migration and 4.8 ± 0.3 nN under guidance. When a cell reversed its migration direction, the magnitudes of the traction force from the leading to the trailing regions also flipped. Conclusion The cell traction force is continuously influenced by topographical guidance, which determines cell migration speed and direction. These results of cell traction force development on various topographies could lead to better cell migration control using topotaxis.
Collapse
Affiliation(s)
- J Hui
- Department of Electronic Engineering, City University of Hong Kong, Kowloon, Hong Kong.,Center for Biosystems, Neuroscience, and Nanotechnology, City University of Hong Kong, Kowloon, Hong Kong
| | - S W Pang
- Department of Electronic Engineering, City University of Hong Kong, Kowloon, Hong Kong.,Center for Biosystems, Neuroscience, and Nanotechnology, City University of Hong Kong, Kowloon, Hong Kong
| |
Collapse
|
13
|
Zhou SF, Gopalakrishnan S, Xu YH, To SKY, Wong AST, Pang SW, Lam YW. Substrates with patterned topography reveal metastasis of human cancer cells. Biomed Mater 2017; 12:055001. [DOI: 10.1088/1748-605x/aa785d] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
14
|
MIYOSHI H, NISHIMURA M, YAMAGATA Y, LIU H, WATANABE Y, SUGAWARA M. Cell migration guided by a groove with branches. ACTA ACUST UNITED AC 2017. [DOI: 10.1299/jbse.16-00613] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- Hiromi MIYOSHI
- Pathophysiological and Health Science Team, RIKEN Center for Life Science Technologies
- Health Metrics Development Team, RIKEN Compass to Healthy Life Research Complex Program
- PRIME, AMED
| | | | - Yutaka YAMAGATA
- Ultrahigh Precision Optics Technology Team, RIKEN Center for Advanced Photonics
| | - Hao LIU
- Graduate School of Engineering, Chiba University
| | - Yasuyoshi WATANABE
- Pathophysiological and Health Science Team, RIKEN Center for Life Science Technologies
- Health Metrics Development Team, RIKEN Compass to Healthy Life Research Complex Program
| | | |
Collapse
|