Gabay B, Levkov K, Berl A, Wise J, Shir-Az O, Vitkin E, Saulis G, Shalom A, Golberg A. Electroporation-Based Biopsy Treatment Planning with Numerical Models and Tissue Phantoms. Ann Biomed Eng 2024; 52:71-88. [PMID: 37154990 DOI: 10.1007/s10439-023-03208-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Accepted: 04/10/2023] [Indexed: 05/10/2023]
Abstract
Molecular sampling with vacuum-assisted tissue electroporation is a novel, minimally invasive method for molecular profiling of solid lesions. In this paper, we report on the design of the battery-powered pulsed electric field generator and electrode configuration for an electroporation-based molecular sampling device for skin cancer diagnostics. Using numerical models of skin electroporation corroborated by the potato tissue phantom model, we show that the electroporated tissue volume, which is the maximum volume for biomarker sampling, strongly depends on the electrode's geometry, needle electrode skin penetration depths, and the applied pulsed electric field protocol. In addition, using excised human basal cell carcinoma (BCC) tissues, we show that diffusion of proteins out of human BCC tissues into water strongly depends on the strength of the applied electric field and on the time after the field application. The developed numerical simulations, confirmed by experiments in potato tissue phantoms and excised human cancer lesions, provide essential tools for the development of electroporation-based molecular markers sampling devices for personalized skin cancer diagnostics.
Collapse
Affiliation(s)
- Batel Gabay
- Porter School of Environment and Earth Sciences, Tel Aviv University, Tel Aviv, Israel
| | - Klimentiy Levkov
- Porter School of Environment and Earth Sciences, Tel Aviv University, Tel Aviv, Israel
| | - Ariel Berl
- Department of Plastic Surgery, Meir Medical Center, Kfar Sava, Israel
| | - Julia Wise
- Porter School of Environment and Earth Sciences, Tel Aviv University, Tel Aviv, Israel
| | - Ofir Shir-Az
- Department of Plastic Surgery, Meir Medical Center, Kfar Sava, Israel
| | - Edward Vitkin
- Porter School of Environment and Earth Sciences, Tel Aviv University, Tel Aviv, Israel
| | - Gintautas Saulis
- Faculty of Natural Sciences, Vytautas Magnus University, Kaunas, Lithuania
| | - Avshalom Shalom
- Department of Plastic Surgery, Meir Medical Center, Kfar Sava, Israel
| | - Alexander Golberg
- Porter School of Environment and Earth Sciences, Tel Aviv University, Tel Aviv, Israel.
| |
Collapse
|
2
|
Hogenes AM, Overduin CG, Slump CH, van Laarhoven CJHM, Fütterer JJ, ten Broek RPG, Stommel MWJ. The Influence of Irreversible Electroporation Parameters on the Size of the Ablation Zone and Thermal Effects: A Systematic Review. Technol Cancer Res Treat 2023; 22:15330338221125003. [PMID: 36598035 PMCID: PMC9830580 DOI: 10.1177/15330338221125003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Revised: 07/16/2022] [Accepted: 08/08/2022] [Indexed: 01/05/2023] Open
Abstract
Introduction: The aim of this study was to review the effect of irreversible electroporation parameter settings on the size of the ablation zone and the occurrence of thermal effects. This insight would help to optimize treatment protocols and effectively ablate a tumor while controlling the occurrence of thermal effects. Methods: Various individual studies report the influence of variation in electroporation parameters on the ablation zone size or occurrence of thermal effects. However, no connections have yet been established between these studies. With the aim of closing the gap in the understanding of and personalizing irreversible electroporation parameter settings, a systematic review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A quality assessment was performed using an in-house developed grading tool based on components of commonly used grading domains. Data on the electroporation parameters voltage, number of electrodes, inter-electrode distance, active needle length, pulse length/number/protocol/frequency, and pulse interval were extracted. Ablation zone size and temperature data were grouped per parameter. Spearman correlation and linear regression were used to define the correlation with outcome measures. Results: A total of 7661 articles were screened, of which 18 preclinical studies (animal and phantom studies) met the inclusion criteria. These studies were graded as moderate (4/18) and low (14/18) quality. Only the applied voltage appeared to be a significant linear predictor of ablation zone size: length, surface, and volume. The pulse number was moderately but nonlinearly correlated with the ablation zone length. Thermal effects were more likely to occur for higher voltages (≥2000 V), higher number of electrodes, and increased active needle length. Conclusion: Firm conclusions are limited since studies that investigated and precisely reported the influence of electroporation parameters on the ablation zone size and thermal effects were scarce and mostly graded low quality. High-quality studies are needed to improve the predictability of the combined effect of variation in parameter combinations and optimize irreversible electroporation treatment protocols.
Collapse
Affiliation(s)
- Annemiek M Hogenes
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Christiaan G Overduin
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Cornelis H Slump
- Department of Robotics and Mechatronics, University of Twente, Enschede, the Netherlands
| | | | - Jurgen J Fütterer
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, the Netherlands
- Department of Robotics and Mechatronics, University of Twente, Enschede, the Netherlands
| | | | - Martijn W J Stommel
- Department of Surgery, Radboud University Medical Center, Nijmegen, the Netherlands
| |
Collapse
|
3
|
Oshin EA, Guo S, Jiang C. Determining tissue conductivity in tissue ablation by nanosecond pulsed electric fields. Bioelectrochemistry 2022; 143:107949. [PMID: 34583212 PMCID: PMC8643318 DOI: 10.1016/j.bioelechem.2021.107949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 09/10/2021] [Accepted: 09/15/2021] [Indexed: 02/03/2023]
Abstract
Nanosecond pulsed electric field (nsPEF) causes the permeabilization of the cell membrane and has been used to non-thermally treat cancerous tissues. As increased permeabilization in membranes were reported to be accompanied by impedance changes, the ablation effect of nsPEF on tissues can be monitored via the changes in tissue conductivity. In this study, effects of nsPEF on biological tissues were evaluated by determining the conductivities of potato and 4 T1-luc breast tumor tissues ex vivo from a murine model subjected to multiple 100-ns, 1-10 kV pulses. Using a four-needle electrode system with a calibrated electrode constant of 1.1 ± 0.1 cm, the conductivities of tissues was determined from both the network-analyzer measurement, before and after treatment, and voltage-current measurement in real-time. The conductivity of the potato tissue was measured for a frequency range of 0.1-3 MHz, and it increased with increasing pulse number and voltage amplitude. The conductivity of the tumor tissue was also observed to increase with pulse number and pulse voltage over a similar frequency range. In addition, the linear correlation between the ablation area in a treated potato tissue and the conductivity change in the tissue suggests that conductivity analysis of biological tissue under treatment could be a fast and sensitive approach to evaluate the effectiveness of a nsPEF treatment.
Collapse
Affiliation(s)
- Edwin A Oshin
- Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, VA, USA; Department of Electrical and Computer Engineering, Old, Dominion University, Norfolk, VA, USA
| | - Siqi Guo
- Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, VA, USA
| | - Chunqi Jiang
- Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, VA, USA; Department of Electrical and Computer Engineering, Old, Dominion University, Norfolk, VA, USA.
| |
Collapse
|
4
|
Four Channel 6.5 kV, 65 A, 100 ns–100 µs Generator with Advanced Control of Pulse and Burst Protocols for Biomedical and Biotechnological Applications. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app112411782] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Pulsed electric fields in the sub-microsecond range are being increasingly used in biomedical and biotechnology applications, where the demand for high-voltage and high-frequency pulse generators with enhanced performance and pulse flexibility is pushing the limits of pulse power solid state technology. In the scope of this article, a new pulsed generator, which includes four independent MOSFET based Marx modulators, operating individually or combined, controlled from a computer user interface, is described. The generator is capable of applying different pulse shapes, from unipolar to bipolar pulses into biological loads, in symmetric and asymmetric modes, with voltages up to 6.5 kV and currents up to 65 A, in pulse widths from 100 ns to 100 µs, including short-circuit protection, current and voltage monitoring. This new scientific tool can open new research possibility due to the flexibility it provides in pulse generation, particularly in adjusting pulse width, polarity, and amplitude from pulse-to-pulse. It also permits operating in burst mode up to 5 MHz in four independent channels, for example in the application of synchronized asymmetric bipolar pulses, which is shown together with other characteristics of the generator.
Collapse
|
5
|
Perera-Bel E, Mercadal B, Garcia-Sanchez T, Gonzalez Ballester MA, Ivorra A. Modeling methods for treatment planning in overlapping electroporation treatments. IEEE Trans Biomed Eng 2021; 69:1318-1327. [PMID: 34559631 DOI: 10.1109/tbme.2021.3115029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Irreversible electroporation (IRE) is a non thermal tissue ablation therapy which is induced by applying high voltage waveforms across electrode pairs. When multiple electrode pairs are sequentially used, the treatment volume (TV) is typically computed as the geometric union of the TVs of individual pairs. However, this method neglects that some regions are exposed to overlapping treatments. Recently, a model describing cell survival probability was introduced which effectively predicted TV with overlapping fields in vivo. However, treatment overlap has yet to be quantified. This study characterizes TV overlap in a controlled in vitro setup with the two existing methods which are compared to an adapted logistic model proposed here. METHODS CHO cells were immobilized in agarose gel. Initially, we characterized the electric field threshold and the cell survival probability for overlapping treatments. Subsequently, we created a 2D setup where we compared and validated the accuracy of the different methods in predicting the TV. RESULTS Overlap can reduce the electric field threshold required to induce cell death, particularly for treatments with low pulse number. However, it does not have a major impact on TV in the models assayed here, and all the studied methods predict TV with similar accuracy. CONCLUSION Treatment overlap has a minor influence in the TV for typical protocols found in IRE therapies. SIGNIFICANCE This study provides evidence that the modeling method used in most pre-clinical and clinical studies seems adequate.
Collapse
|
6
|
Mansourian M, Firoozabadi M, Hassan ZM. The role of 217-Hz ELF magnetic fields emitted from GSM mobile phones on electrochemotherapy mechanisms. Electromagn Biol Med 2020; 39:239-249. [PMID: 32410511 DOI: 10.1080/15368378.2020.1762635] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
Electrochemotherapy (ECT), the combination of electric pulses (EPs) and an anticancer drug, is a type of cancer treatment method. We investigated the effect of 217-Hz magnetic fields (MFs) similar to that generated by GSM900 mobile phones, as intervening factors, on proposed mechanisms of ECT including permeability, tumor hypoxia and immune system response. The 4T1 cells were exposed to extremely low-frequency (ELF)-MFs at 93, 120 or 159 µT intensities, generated by Helmholtz coils 10 min, and then put in individual groups, comprising no treatment, chemotherapy, EPs or ECT. The cell viability was evaluated. Then, two treatment protocols were selected for in vivo experiments. The mice with 4T1 tumor cells were exposed to ELF-MFs 10 min/day until the day their tumors reached 8 mm in diameter. Then, the tumors were treated to ECT. Tumor hypoxia and immune system response were analyzed through immunohistochemistry assay and enzyme-linked immunosorbent assay technique, respectively. The results in vitro indicated a significant decreased ECT efficacy of 60 V/cm, 5 kHz at the flux density of 93 µT. The results in vivo showed that pre-exposure to ELF-MFs could increase tumor hypoxia induced by ECT. In addition, exposure to ELF-MFs before ECT caused a significant increase in interferon-γ/interleukin-4 in comparison with ECT alone. More studies, including studies on the effect of ELF-MFs emitted from mobile phones on tumor volume changes induced by ECT, are needed to elucidate how the process of ECT is influenced by the MFs.
Collapse
Affiliation(s)
- Mahsa Mansourian
- Department of Medical Physics, Faculty of Medical Science, Tarbiat Modares University , Tehran, Iran
| | - Mohammad Firoozabadi
- Department of Medical Physics, Faculty of Medical Science, Tarbiat Modares University , Tehran, Iran
| | - Zuhair Mohammad Hassan
- Department of Immunology, Faculty of Medical Science, Tarbiat Modares University , Tehran, Iran
| |
Collapse
|
7
|
Golberg A, Sheviryov J, Solomon O, Anavy L, Yakhini Z. Molecular harvesting with electroporation for tissue profiling. Sci Rep 2019; 9:15750. [PMID: 31673038 PMCID: PMC6823461 DOI: 10.1038/s41598-019-51634-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Accepted: 10/03/2019] [Indexed: 01/01/2023] Open
Abstract
Recent developments in personalized medicine are based on molecular measurement steps that guide personally adjusted medical decisions. A central approach to molecular profiling consists of measuring DNA, RNA, and/or proteins in tissue samples, most notably in and around tumors. This measurement yields molecular biomarkers that are potentially predictive of response and of tumor type. Current methods in cancer therapy mostly use tissue biopsy as the starting point of molecular profiling. Tissue biopsies involve a physical resection of a small tissue sample, leading to localized tissue injury, bleeding, inflammation and stress, as well as to an increased risk of metastasis. Here we developed a technology for harvesting biomolecules from tissues using electroporation. We show that tissue electroporation, achieved using a combination of high-voltage short pulses, 50 pulses 500 V cm-1, 30 µs, 1 Hz, with low-voltage long pulses 50 pulses 50 V cm-1, 10 ms, delivered at 1 Hz, allows for tissue-specific extraction of RNA and proteins. We specifically tested RNA and protein extraction from excised kidney and liver samples and from excised HepG2 tumors in mice. Further in vivo development of extraction methods based on electroporation can drive novel approaches to the molecular profiling of tumors and of tumor environment and to related diagnosis practices.
Collapse
Affiliation(s)
- Alexander Golberg
- Porter School of Environment and Earth Sciences, Tel Aviv University, Tel Aviv, Israel.
| | - Julia Sheviryov
- Porter School of Environment and Earth Sciences, Tel Aviv University, Tel Aviv, Israel
| | - Oz Solomon
- School of Computer Science, Herzliya Interdisciplinary Center, Herzliya, Israel
| | - Leon Anavy
- Computer Science Department, Technion, Haifa, Israel
| | - Zohar Yakhini
- School of Computer Science, Herzliya Interdisciplinary Center, Herzliya, Israel.
- Computer Science Department, Technion, Haifa, Israel.
| |
Collapse
|
8
|
Lv Y, Yao C, Rubinsky B. A 2-D Cell Layer Study on Synergistic Combinations of High-Voltage and Low-Voltage Irreversible Electroporation Pulses. IEEE Trans Biomed Eng 2019; 67:957-965. [PMID: 31265380 DOI: 10.1109/tbme.2019.2925774] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Irreversible electroporation (IRE) employs brief, high-electric field pulses to ablate tumors while preserving the extracellular matrix. Recently, we showed that combining short high-voltage (SHV) IRE pulses and long low-voltage (LLV) IRE pulses can enlarge the tissue ablation region, presumably through a synergistic effect. OBJECTIVE The goal of this study is to further investigate the effect of this combination on a 2-D cell layer tumor model. METHODS 2-D layers of tumor cells are exposed to various SHV and LLV combinations, and the results of propidium iodide (PI) and fluorescein diacetate staining are examined to correlate treatment protocols with the ensuing irreversible and reversible electroporation areas. RESULTS The combination of SHV+LLV pulses produces a larger area of electroporation and ablation than LLV+SHV pulses, LLV pulses alone, and SHV pulses alone. CONCLUSION Judiciously combining SHV and LLV pulses can produce a synergistic effect that enlarges the electroporation-induced ablation area. A hypothetical explanation for this effect is that it involves a combination of pore expansion and electrolysis induced by LLV pulses in the area that had been reversibly permeabilized by the SHV pulses. SIGNIFICANCE This paper is valuable for the design of improved IRE protocols and provides a hypothesis for the mechanisms involved.
Collapse
|
9
|
A Conceivable Mechanism Responsible for the Synergy of High and Low Voltage Irreversible Electroporation Pulses. Ann Biomed Eng 2019; 47:1552-1563. [PMID: 30953220 DOI: 10.1007/s10439-019-02258-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2018] [Accepted: 03/29/2019] [Indexed: 12/12/2022]
Abstract
Irreversible electroporation (IRE), is a new non-thermal tissue ablation technology in which brief high electric field pulses are delivered across the target tissue to induce cell death by irreversible permeabilization of the cell membrane. A deficiency of conventional IRE is that the ablation zone is relatively small, bounded by the irreversible electroporation isoelectric field margin. In the previous studies we have introduced a new treatment protocol that combines few short high voltage (SHV) pulses with long low-voltage (LLV) pulses. In the previous studies, we also have shown that the addition of few SHV pulses increases by almost a factor of two the area ablated by a protocol that employs only the LLV pulses. This study employs potato and gel phantom to generate a plausible explanation for the mechanism. The study provides circumstantial evidence that the mechanism involved is the production of electrolytic compounds by the LLV pulse sequence, which causes tissue ablation beyond the margin of the irreversible electroporation isoelectric field generated by the SHV pulses, presumable to the reversible electroporation isoelectric field margin generated by the SHV pulses.
Collapse
|
10
|
Zhao Y, Liu H, Bhonsle SP, Wang Y, Davalos RV, Yao C. Ablation outcome of irreversible electroporation on potato monitored by impedance spectrum under multi-electrode system. Biomed Eng Online 2018; 17:126. [PMID: 30236121 PMCID: PMC6148960 DOI: 10.1186/s12938-018-0562-9] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2018] [Accepted: 09/17/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Irreversible electroporation (IRE) therapy relies on pulsed electric fields to non-thermally ablate cancerous tissue. Methods for evaluating IRE ablation in situ are critical to assessing treatment outcome. Analyzing changes in tissue impedance caused by electroporation has been proposed as a method for quantifying IRE ablation. In this paper, we assess the hypothesis that irreversible electroporation ablation outcome can be monitored using the impedance change measured by the electrode pairs not in use, getting more information about the ablation size in different directions. METHODS Using a square four-electrode configuration, the two diagonal electrodes were used to electroporate potato tissue. Next, the impedance changes, before and after treatment, were measured from different electrode pairs and the impedance information was extracted by fitting the data to an equivalent circuit model. Finally, we correlated the change of impedance from various electrode pairs to the ablation geometry through the use of fitted functions; then these functions were used to predict the ablation size and compared to the numerical simulation results. RESULTS The change in impedance from the electrodes used to apply pulses is larger and has higher deviation than the other electrode pairs. The ablation size and the change in resistance in the circuit model correlate with various linear functions. The coefficients of determination for the three functions are 0.8121, 0.8188 and 0.8691, respectively, showing satisfactory agreement. The functions can well predict the ablation size under different pulse numbers, and in some directions it did even better than the numerical simulation method, which used different electric field thresholds for different pulse numbers. CONCLUSIONS The relative change in tissue impedance measured from the non-energized electrodes can be used to assess ablation size during treatment with IRE according to linear functions.
Collapse
Affiliation(s)
- Yajun Zhao
- State Key Laboratory of Power Transmission Equipment and System Security and New Technology, School of Electrical Engineering, Chongqing University, No. 174 Shazhengjie, Shapingba District, Chongqing, 400044, China.,Department of Biomedical Engineering and Mechanics, Virginia Tech, 329 ICTAS Stanger St (0298), Blacksburg, VA, 24061, USA
| | - Hongmei Liu
- State Key Laboratory of Power Transmission Equipment and System Security and New Technology, School of Electrical Engineering, Chongqing University, No. 174 Shazhengjie, Shapingba District, Chongqing, 400044, China
| | - Suyashree P Bhonsle
- Department of Biomedical Engineering and Mechanics, Virginia Tech, 329 ICTAS Stanger St (0298), Blacksburg, VA, 24061, USA
| | - Yilin Wang
- State Key Laboratory of Power Transmission Equipment and System Security and New Technology, School of Electrical Engineering, Chongqing University, No. 174 Shazhengjie, Shapingba District, Chongqing, 400044, China
| | - Rafael V Davalos
- Department of Biomedical Engineering and Mechanics, Virginia Tech, 329 ICTAS Stanger St (0298), Blacksburg, VA, 24061, USA.
| | - Chenguo Yao
- State Key Laboratory of Power Transmission Equipment and System Security and New Technology, School of Electrical Engineering, Chongqing University, No. 174 Shazhengjie, Shapingba District, Chongqing, 400044, China.
| |
Collapse
|
11
|
Li C, Ke Q, Yao C, Mi Y, Liu H, Lv Y, Yao C. Cell electrofusion based on nanosecond/microsecond pulsed electric fields. PLoS One 2018; 13:e0197167. [PMID: 29795594 PMCID: PMC5967737 DOI: 10.1371/journal.pone.0197167] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2017] [Accepted: 04/27/2018] [Indexed: 11/19/2022] Open
Abstract
Traditionally, microsecond pulsed electric field was widely used in cell electrofusion technology. However, it was difficult to fuse the cells with different sizes. Because the effect of electroporation based on microsecond pulses was greatly influenced by cell sizes. It had been reported that the differences between cell sizes can be ignored when cells were exposed to nanosecond pulses. However, pores induced by those short nanosecond pulses tended to be very small (0.9 nm) and the pores were more easy to recover. In this work, a finite element method was used to simulate the distribution, radius and density of the pores. The innovative idea of "cell electrofusion based on nanosecond/microsecond pulses" was proposed in order to combine the advantages of nanosecond pulses and microsecond pulses. The model consisted of two contact cells with different sizes. Three kinds of pulsed electric fields were made up of two 100-ns, 10-kV/cm pulses; two 10-μs, 1-kV/cm pulses; and a sequence of a 100-ns, 10-kV/cm pulse, followed by a 10-μs, 1-kV/cm pulse. Some obvious advantageous can be found when nanosecond/microsecond pulses were considered. The pore radius was large enough (70nm) and density was high (5×1013m-2) in the cell junction area. Moreover, pores in the non-contact area of the cell membrane were small (1-10 nm) and sparse (109-1012m-2). Areas where the transmembrane voltage was higher than 1V were only concentrated in the cell junction. The transmembrane voltage of other areas were at most 0.6V when we tested the rest of the cell membrane. Cell fusion efficiency can be improved remarkably because electroporation was concentrated in the cell contact area.
Collapse
Affiliation(s)
- Chengxiang Li
- The State Key Laboratory of Power Transmission Equipment & System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
| | - Qiang Ke
- The State Key Laboratory of Power Transmission Equipment & System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
| | - Chenguo Yao
- The State Key Laboratory of Power Transmission Equipment & System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
| | - Yan Mi
- The State Key Laboratory of Power Transmission Equipment & System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
| | - Hongmei Liu
- The State Key Laboratory of Power Transmission Equipment & System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
| | - Yanpeng Lv
- The State Key Laboratory of Power Transmission Equipment & System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
| | - Cheng Yao
- The State Key Laboratory of Power Transmission Equipment & System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
| |
Collapse
|
12
|
Yang Y, Moser MAJ, Zhang E, Zhang W, Zhang B. Development of a statistical model for cervical cancer cell death with irreversible electroporation in vitro. PLoS One 2018; 13:e0195561. [PMID: 29694357 PMCID: PMC5919048 DOI: 10.1371/journal.pone.0195561] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2018] [Accepted: 03/23/2018] [Indexed: 12/18/2022] Open
Abstract
PURPOSE The aim of this study was to develop a statistical model for cell death by irreversible electroporation (IRE) and to show that the statistic model is more accurate than the electric field threshold model in the literature using cervical cancer cells in vitro. METHODS HeLa cell line was cultured and treated with different IRE protocols in order to obtain data for modeling the statistical relationship between the cell death and pulse-setting parameters. In total, 340 in vitro experiments were performed with a commercial IRE pulse system, including a pulse generator and an electric cuvette. Trypan blue staining technique was used to evaluate cell death after 4 hours of incubation following IRE treatment. Peleg-Fermi model was used in the study to build the statistical relationship using the cell viability data obtained from the in vitro experiments. A finite element model of IRE for the electric field distribution was also built. Comparison of ablation zones between the statistical model and electric threshold model (drawn from the finite element model) was used to show the accuracy of the proposed statistical model in the description of the ablation zone and its applicability in different pulse-setting parameters. RESULTS The statistical models describing the relationships between HeLa cell death and pulse length and the number of pulses, respectively, were built. The values of the curve fitting parameters were obtained using the Peleg-Fermi model for the treatment of cervical cancer with IRE. The difference in the ablation zone between the statistical model and the electric threshold model was also illustrated to show the accuracy of the proposed statistical model in the representation of ablation zone in IRE. CONCLUSIONS This study concluded that: (1) the proposed statistical model accurately described the ablation zone of IRE with cervical cancer cells, and was more accurate compared with the electric field model; (2) the proposed statistical model was able to estimate the value of electric field threshold for the computer simulation of IRE in the treatment of cervical cancer; and (3) the proposed statistical model was able to express the change in ablation zone with the change in pulse-setting parameters.
Collapse
Affiliation(s)
- Yongji Yang
- Tumor Ablation Group, Complex and Intelligent Systems Research Center, East China University of Science and Technology, Shanghai, China
| | - Michael A. J. Moser
- Department of Surgery, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| | - Edwin Zhang
- Division of Vascular & Interventional Radiology, Department of Medical Imaging, University of Toronto, Toronto, Ontario, Canada
| | - Wenjun Zhang
- Tumor Ablation Group, Complex and Intelligent Systems Research Center, East China University of Science and Technology, Shanghai, China
| | - Bing Zhang
- Biomedical Science and Technology Research Center, School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, China
| |
Collapse
|
13
|
Yao C, Lv Y, Zhao Y, Dong S, Liu H, Ma J. Synergistic combinations of short high-voltage pulses and long low-voltage pulses enhance irreversible electroporation efficacy. Sci Rep 2017; 7:15123. [PMID: 29123231 PMCID: PMC5680269 DOI: 10.1038/s41598-017-15494-3] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2017] [Accepted: 10/27/2017] [Indexed: 12/18/2022] Open
Abstract
Irreversible electroporation (IRE) uses ~100 μs pulsed electric fields to disrupt cell membranes for solid tumor ablation. Although IRE has achieved exciting preliminary clinical results, implementing IRE could be challenging because of volumetric limitations at the ablation region. Combining short high-voltage (SHV: 1600V, 2 μs, 1 Hz, 20 pulses) pulses with long low-voltage (LLV: 240-480 V, 100 μs, 1 Hz, 60-80 pulses) pulses induces a synergistic effect that enhances IRE efficacy. Here, cell cytotoxicity and tissue ablation were investigated. The results show that combining SHV pulses with LLV pulses induced SKOV3 cell death more effectively, and compared to either SHV pulses or LLV pulses applied alone, the combination significantly enhanced the ablation region. Particularly, prolonging the lag time (100 s) between SHV and LLV pulses further reduced cell viability and enhanced the ablation area. However, the sequence of SHV and LLV pulses was important, and the LLV + SHV combination was not as effective as the SHV + LLV combination. We offer a hypothesis to explain the synergistic effect behind enhanced cell cytotoxicity and enlarged ablation area. This work shows that combining SHV pulses with LLV pulses could be used as a focal therapy and merits investigation in larger pre-clinical models and microscopic mechanisms.
Collapse
Affiliation(s)
- Chenguo Yao
- The State Key Laboratory of Power Transmission Equipment and System Security and New Technology, the School of Electrical Engineering, Chongqing University, Chongqing, 400030, China.
| | - Yanpeng Lv
- The State Key Laboratory of Power Transmission Equipment and System Security and New Technology, the School of Electrical Engineering, Chongqing University, Chongqing, 400030, China.
| | - Yajun Zhao
- The State Key Laboratory of Power Transmission Equipment and System Security and New Technology, the School of Electrical Engineering, Chongqing University, Chongqing, 400030, China
| | - Shoulong Dong
- The State Key Laboratory of Power Transmission Equipment and System Security and New Technology, the School of Electrical Engineering, Chongqing University, Chongqing, 400030, China
| | - Hongmei Liu
- The State Key Laboratory of Power Transmission Equipment and System Security and New Technology, the School of Electrical Engineering, Chongqing University, Chongqing, 400030, China
| | - Jianhao Ma
- The State Key Laboratory of Power Transmission Equipment and System Security and New Technology, the School of Electrical Engineering, Chongqing University, Chongqing, 400030, China
| |
Collapse
|