1
|
Kaida T, Ono T, Tokunaga T, Takada K, Tokuda S, Kuwabara N, Kawamorita T, Kamiya K, Shoji N, Miyata K. Prevalence of Accommodative Microfluctuations in Eyes after Cataract Surgery. J Clin Med 2023; 12:5135. [PMID: 37568536 PMCID: PMC10419933 DOI: 10.3390/jcm12155135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 07/18/2023] [Accepted: 08/03/2023] [Indexed: 08/13/2023] Open
Abstract
BACKGROUND We aimed to evaluate the existence of accommodative microfluctuations in eyes after cataract surgery. METHODS This retrospective observational cohort study included 1160 eyes of 713 patients (mean age: 72.5 ± 8.3 years) who underwent phacoemulsification, intraocular lens insertion, and an evaluation of accommodative microfluctuations with an autorefractometer. Patients with posterior segment disorders resulting in visual acuity impairment and those with unavailable medical information were excluded. High-frequency components (HFCs), between 1.0-2.3 Hz, based on fast Fourier transform analysis of the accommodative microfluctuation data were examined at postoperative 2-3 (2 M) and 6 months (6 M). The relationships between the HFCs and patient age, manifest refraction, and axial length were analyzed. RESULTS Increased HFC values (>65) were observed at a constant rate after cataract surgery, with prevalence rates of 33.4% at 2 M and 34.7% at 6 M. Postoperatively, at 2 M, increased HFC values were significantly more common for eyes with axial length ≥26 mm than for those with axial length <26 mm (p = 0.0056). However, they were not significantly correlated to age or postoperative manifest refraction. CONCLUSIONS At 2 M postoperatively, increased HFC values presented more frequently in eyes with a greater axial length; hence, the precise detection and understanding of postoperative accommodative spasms in high myopia patients is important.
Collapse
Affiliation(s)
- Tomoko Kaida
- Department of Ophthalmology, Miyata Eye Hospital, Miyazaki 885-0051, Japan (T.T.); (S.T.)
| | - Takashi Ono
- Department of Ophthalmology, Miyata Eye Hospital, Miyazaki 885-0051, Japan (T.T.); (S.T.)
- Department of Ophthalmology, Graduate School of Medicine, University of Tokyo, Tokyo 113-8654, Japan
| | - Tadatoshi Tokunaga
- Department of Ophthalmology, Miyata Eye Hospital, Miyazaki 885-0051, Japan (T.T.); (S.T.)
| | - Keita Takada
- Department of Ophthalmology, Miyata Eye Hospital, Miyazaki 885-0051, Japan (T.T.); (S.T.)
| | - Shota Tokuda
- Department of Ophthalmology, Miyata Eye Hospital, Miyazaki 885-0051, Japan (T.T.); (S.T.)
| | - Naoto Kuwabara
- Department of Ophthalmology, Miyata Eye Hospital, Miyazaki 885-0051, Japan (T.T.); (S.T.)
| | - Takushi Kawamorita
- Department of Orthoptics and Visual Science, Kitasato University School of Allied Health Sciences, Sagamihara 252-0373, Japan
| | - Kazutaka Kamiya
- Department of Orthoptics and Visual Science, Kitasato University School of Allied Health Sciences, Sagamihara 252-0373, Japan
| | - Nobuyuki Shoji
- Department of Ophthalmology, School of Medicine, Kitasato University, Sagamihara 252-0374, Japan
| | - Kazunori Miyata
- Department of Ophthalmology, Miyata Eye Hospital, Miyazaki 885-0051, Japan (T.T.); (S.T.)
| |
Collapse
|
2
|
Wolffsohn JS, Davies LN, Sheppard AL. New insights in presbyopia: impact of correction strategies. BMJ Open Ophthalmol 2023. [DOI: 10.1136/bmjophth-2022-001122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
Presbyopia occurs when the physiologically normal age-related reduction in the eyes focusing range reaches a point, when optimally corrected for distance vision, that the clarity of vision at near is insufficient to satisfy an individual’s requirements. Hence, it is more about the impact it has on an individual’s visual ability to function in their environment to maintain their lifestyle than a measured loss of focusing ability. Presbyopia has a significant impact on an individual’s quality of life and emotional state. While a range of amelioration strategies exist, they are often difficult to access in the developing world and prescribing is generally not optimal even in developed countries. This review identified the need for a standardised definition of presbyopia to be adopted. An appropriate battery of tests should be applied in evaluating presbyopic management options and the results of clinical trials should be published (even if unsuccessful) to accelerate the provision of better outcomes for presbyopes.
Collapse
|
3
|
Short Tear Breakup Time Could Exacerbate the Progression of Presbyopia in Women. BIOMED RESEARCH INTERNATIONAL 2022; 2022:8159669. [PMID: 35127945 PMCID: PMC8816554 DOI: 10.1155/2022/8159669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/21/2021] [Revised: 11/25/2021] [Accepted: 01/07/2022] [Indexed: 11/17/2022]
Abstract
Purpose The contributory factors and symptoms for presbyopia progression have not been fully determined. The purpose of the study was to compare presbyopia progression in subjects with short and normal tear breakup time and to explore the severity of common ocular symptoms associated with presbyopia progression. Method We conducted a clinic-based, retrospective, cross-sectional study. Inclusion criteria were bilateral phakic patients aged 40–69 years with best-corrected distance visual acuity better than 20/30, and exclusion criteria were the use of glaucoma eye drops, any disease affecting vision, or history of ocular surgery. We measured the binocular near add power and compared the results using Kaplan-Meier analysis. Association between near add power and ocular symptoms was explored. Results There were 1411 participants (mean age of 50.1 years). There were no significant differences in age, intraocular pressure, spherical equivalent, astigmatism, or anisometropia between the sexes. Kaplan-Meier analysis indicated that women with short tear breakup time reached the endpoint (near add power of +3.00 D) significantly earlier than those with normal tear breakup time (P = 0.043; Cox-Mantel test). Eye fatigue was most severe in the group with an add power of 1.25-2.00 D. Near add power was correlated with hyperopia, astigmatic errors, and anisometropia. Conclusions This study suggests an exacerbation of presbyopia progression in women with short tear breakup time. Eye fatigue was most severe in those with an add power of 1.25-2.00 D.
Collapse
|
4
|
Lee SH, Kim M, Kim H, Park CY. Visual fatigue induced by watching virtual reality device and the effect of anisometropia. ERGONOMICS 2021; 64:1522-1531. [PMID: 34270388 DOI: 10.1080/00140139.2021.1957158] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Accepted: 07/14/2021] [Indexed: 06/13/2023]
Abstract
The effect of small anisometropia on visual fatigue when using virtual reality (VR) devices was investigated. Participants (n = 34) visited three times. In the first visit, VR exposure (10 min) was conducted with the full correction of the refractive error of both eyes. Experimental anisometropia was induced by adding a + 1.0 dioptre spherical lens either on the dominant eyes in the second visit or on the non-dominant eyes in the third visit. At each visit, the participants played a predetermined video game using a head-mounted display VR for 10 min. Visual fatigue was assessed before and after playing VR game using the Virtual Reality Symptom Questionnaire (VRSQ) and high-frequency component of accommodative microfluctuation. Results showed that watching VR induced significant increase of VRSQ score, significant decrease in the maximum accommodation power and objective increase in visual fatigue. Experimental anisometropia induction either on the dominant or non-dominant eyes did not aggravate visual fatigue. Practitioner summary: Mild differences in refractive error (up to 1.0 dioptre) between both eyes do not significantly increase ocular fatigue by viewing virtual reality device (10 min). The impact of small anisometropia may be limited in developing a virtual reality device. Abbreviations: VR: virtual reality; VRSQ: virtual reality symptom questionnaire; HMD: head-mounted display; HFC: high-frequency component.
Collapse
Affiliation(s)
- Sang Hyeok Lee
- Department of Ophthalmology, Dongguk University, Ilsan Hospital, Goyang, South Korea
| | - Martha Kim
- Department of Ophthalmology, Dongguk University, Ilsan Hospital, Goyang, South Korea
| | - Hyosun Kim
- Samsung Display, Display R&D center, Suwon, South Korea
| | - Choul Yong Park
- Department of Ophthalmology, Dongguk University, Ilsan Hospital, Goyang, South Korea
| |
Collapse
|
5
|
Chatterjee S, Agrawal D. Short tear film breakup time-type of dry eye in India. Indian J Ophthalmol 2021; 69:3463-3468. [PMID: 34826975 PMCID: PMC8837354 DOI: 10.4103/ijo.ijo_327_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Purpose The aim of this study was to describe the clinical characteristics and risk factors of short tear film break-up time (TBUT) type of dry eye disease and compare it with other types of dry eye diseases. Methods This cross-sectional study included 570 patients (≥ 20 years) from the outpatient department using systematic random sampling. Results The age-adjusted prevalence of short TBUT type of dry eye disease was 5.4% (95% confidence interval: 3.2-6.8%). There was no difference (P > 0.05) between the total and subscale scores of the Ocular Surface Disease Index® questionnaire between patients with short TBUT and those with aqueous tear deficiency. Both these groups differed significantly (P < 0.05) in the findings of TBUT, Schirmer I test, and Lissamine green staining score. The common symptoms in patients with short TBUT type of dry eye disease were eye fatigue (25.4%), heaviness in the eye (19.7%), and an uncomfortable sensation (14.1%). The symptoms in the aqueous tear deficiency group were light sensitivity (28.2%), dryness (19.2%), burning (13.0%), foreign body sensation (12.8%), and blurring of vision (14.1%). The risk factors associated with short TBUT type of dry eye disease were the presence of meibomian gland dysfunction (odds ratio: 3.759 [95% confidence interval: 2.135-6.618], P < 0.0001) and female sex [odds ratio: 1.954 (95% confidence interval: 1.042-3.667), P = 0.037]. Conclusion Patients with short TBUT type of dry eye disease have symptom severity similar to aqueous tear-deficient dry eyes, but the pattern is different. The finding of this type of dry eye disease in India indicates its global presence, and ophthalmologists should consider it in their differential diagnoses.
Collapse
Affiliation(s)
- Samrat Chatterjee
- Cornea and Anterior Segment Services, MGM Eye Institute, Raipur, Chhattisgarh, India
| | - Deepshikha Agrawal
- Cornea and Anterior Segment Services, MGM Eye Institute, Raipur, Chhattisgarh, India
| |
Collapse
|
6
|
Tsubota K, Pflugfelder SC, Liu Z, Baudouin C, Kim HM, Messmer EM, Kruse F, Liang L, Carreno-Galeano JT, Rolando M, Yokoi N, Kinoshita S, Dana R. Defining Dry Eye from a Clinical Perspective. Int J Mol Sci 2020; 21:ijms21239271. [PMID: 33291796 PMCID: PMC7730816 DOI: 10.3390/ijms21239271] [Citation(s) in RCA: 107] [Impact Index Per Article: 26.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Revised: 11/21/2020] [Accepted: 11/27/2020] [Indexed: 12/21/2022] Open
Abstract
Over the past decades, the number of patients with dry eye disease (DED) has increased dramatically. The incidence of DED is higher in Asia than in Europe and North America, suggesting the involvement of cultural or racial factors in DED etiology. Although many definitions of DED have been used, discrepancies exist between the various definitions of dry eye disease (DED) used across the globe. This article presents a clinical consensus on the definition of DED, as formulated in four meetings with global DED experts. The proposed new definition is as follows: “Dry eye is a multifactorial disease characterized by a persistently unstable and/or deficient tear film (TF) causing discomfort and/or visual impairment, accompanied by variable degrees of ocular surface epitheliopathy, inflammation and neurosensory abnormalities.” The key criteria for the diagnosis of DED are unstable TF, inflammation, ocular discomfort and visual impairment. This definition also recommends the assessment of ocular surface epitheliopathy and neurosensory abnormalities in each patient with suspected DED. It is easily applicable in clinical practice and should help practitioners diagnose DED consistently. This consensus definition of DED should also help to guide research and clinical trials that, to date, have been hampered by the lack of an established surrogate endpoint.
Collapse
Affiliation(s)
- Kazuo Tsubota
- Department of Ophthalmology, Keio University School of Medicine, Tokyo 160-8582, Japan
- Correspondence: ; Tel.: +81-3-5363-3219
| | | | - Zuguo Liu
- Eye Institute of Xiamen University, Xiamen 361102, China;
| | | | - Hyo Myung Kim
- Korea University Medical Center, Anam Hospital, Seoul 02841, Korea;
| | - Elisabeth M. Messmer
- Department of Ophthalmology, Ludwig Maximilian University, 80539 Munich, Germany;
| | - Friedrich Kruse
- Department of Ophthalmology, University of Erlangen-Nuremberg, 91054 Erlangen, Germany;
| | - Lingyi Liang
- Zhongshan Ophthalmic Center, Guangzhou 510060, China;
| | | | - Maurizio Rolando
- ISPRE OPHTHALMICS (Instituto di Medicina Oftalmica), 16129 Genoa, Italy;
| | - Norihiko Yokoi
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan;
| | - Shigeru Kinoshita
- Department of Frontier Medical Science and Technology for Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan;
| | - Reza Dana
- Cornea & Refractive Surgery, Massachusetts Eye & Ear, Boston, MA 02114, USA; (J.T.C.-G.); (R.D.)
| |
Collapse
|
7
|
Ji MH, Moshfeghi DM, Periman L, Kading D, Matossian C, Walman G, Markham S, Mu A, Jayaram A, Gertner M, Karpecki P, Friedman NJ. Novel Extranasal Tear Stimulation: Pivotal Study Results. Transl Vis Sci Technol 2020; 9:23. [PMID: 33244443 PMCID: PMC7683850 DOI: 10.1167/tvst.9.12.23] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Accepted: 10/07/2020] [Indexed: 01/15/2023] Open
Abstract
Purpose To evaluate the efficacy and safety of iTEAR, a novel, portable, sonic external neuromodulation device, for the treatment of dry eye disease (DED). Methods This was a multicenter, open-label, single-arm clinical trial that included adult patients with DED with a Schirmer score of ≤10 mm in at least one eye. Enrolled subjects were instructed to apply the study device at least twice per day for 30 seconds bilaterally to the external nasal nerve. After the initial baseline visit, patients were followed up at days 3, 14, 30, 90, and 180. The primary efficacy endpoint was the Schirmer index (change from unstimulated to stimulated tear production as measured by the Schirmer test) at day 30. The major secondary endpoint was the change in symptoms of DED at day 30 evaluated using the Ocular Surface Disease Index (OSDI). Results A total of 101 subjects evaluated at day 30 had a mean Schirmer index of 9.4 mm (95% confidence interval [CI], 7.4–11.3), and the baseline OSDI improved by an average of 14.4 (95% CI, 11.1–17.7). Both endpoints were highly statistically and clinically significant at all time points. There were two mild unanticipated adverse events definitely related to the device. Conclusions The safety and efficacy of the iTEAR device observed in this study support its indication for treating DED. Translational Relevance Neurostimulation has the potential to improve signs and symptoms of DED.
Collapse
Affiliation(s)
- Marco H Ji
- Horngren Family Vitreoretinal Center, Byers Eye Institute, Department of Ophthalmology, Stanford University School of Medicine, Palo Alto, CA, USA.,Department of Medicine, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Darius M Moshfeghi
- Horngren Family Vitreoretinal Center, Byers Eye Institute, Department of Ophthalmology, Stanford University School of Medicine, Palo Alto, CA, USA
| | | | | | | | | | | | - Andy Mu
- NV Eye Surgery, Las Vegas, NV, USA
| | - Ann Jayaram
- Mid-Peninsula Ophthalmology Medical Group, Menlo Park, CA, USA
| | | | | | - Neil J Friedman
- Mid-Peninsula Ophthalmology Medical Group, Menlo Park, CA, USA
| |
Collapse
|
8
|
Loss of Concentration May Occur by Blink Inhibition in DED Simulation Models. Life (Basel) 2020; 10:life10050061. [PMID: 32414123 PMCID: PMC7281572 DOI: 10.3390/life10050061] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Revised: 05/12/2020] [Accepted: 05/12/2020] [Indexed: 01/08/2023] Open
Abstract
Purpose: Patients with dry eye disease (DED) often suffer productivity loss and distress due to bothersome symptoms. The aim of this study was to objectively quantify and compare productivity-related emotional states obtained from brain waveforms in natural and simulated DED conditions. Method: 25 healthy adults (6 females and 19 males; mean age ± standard deviation, 22.6 ± 8.3 years) were recruited for the study, which included an electroencephalogram (EEG), measurements of interblinking time, and questionnaires. DED was simulated by suppressing blinking, while spontaneous blinking served as a control. Elements of concentration, stress, and alertness were extracted from the raw EEG waveforms and the values were compared during spontaneous and suppressed blinking. The relation with DED-related parameters was then explored. Written informed consent was obtained from all participants. Results: All participants successfully completed the experimental protocol. Concentration significantly decreased during suppressed blinking in 20 participants (80%), when compared with spontaneous blinking, whereas there were no or small differences in stress or alertness between spontaneous and suppressed blinking. The change in concentration was correlated with interblinking time (β = −0.515, p = 0.011). Conclusion: Loss of concentration was successfully captured in an objective manner using the EEG. The present study may enable us to understand how concentration is affected during blink suppression, which may happen in office work, particularly during computer tasks. Further study using detailed ocular evaluation is warranted to explore the effect of different interventions.
Collapse
|
9
|
Changes in accommodative micro-fluctuations after wearing contact lenses of different optical designs. Cont Lens Anterior Eye 2020; 43:493-496. [PMID: 32201056 DOI: 10.1016/j.clae.2020.03.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Revised: 03/09/2020] [Accepted: 03/09/2020] [Indexed: 11/22/2022]
Abstract
PURPOSE Accommodative micro-fluctuations (AMF) are small dioptric changes during accommodation. The aim of this study was to evaluate and compare changes in AMF when wearing silicone hydrogel contact lenses of two different optical designs. METHODS A multi-centre, randomised, cross-over, non-dispensing study was conducted on 68 adapted contact lens wearers aged 25-35 years to compare AMF responses to a spherical and aspheric silicone hydrogel (comfilcon A) lens designs. A Righton Speedy "i" series Auto Refractometer in accommodation analyser mode was utilized before and after reading a standard text in font size 8 on an iPhone 5 for 20 min at a 25 cm viewing distance. Phone screen brightness was set by automatic adjustment mode and ambient illumination was controlled at all sites. RESULTS Mean ± SD AMF change from before to after the reading task was 2.25 ± 5.6 and 0.13 ± 5.7 (relative values) for the spherical and aspheric lens designs, respectively. The difference was statistically significant (P = 0.017, Paired t-test). CONCLUSIONS The smaller change in AMF when using an aspheric lens design suggests reduced ciliary muscle stress when reading print on a smart phone at a close distance for short periods (20 min). Contact lens wearers who frequently use digital devices and are experiencing eye strain may benefit from switching from a spherical design to one that incorporates aspheric optics.
Collapse
|
10
|
Kojima T, Dogru M, Kawashima M, Nakamura S, Tsubota K. Advances in the diagnosis and treatment of dry eye. Prog Retin Eye Res 2020; 78:100842. [PMID: 32004729 DOI: 10.1016/j.preteyeres.2020.100842] [Citation(s) in RCA: 72] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2019] [Revised: 01/19/2020] [Accepted: 01/24/2020] [Indexed: 02/07/2023]
Abstract
The core mechanism of dry eye is the tear film instability. Tear film-oriented diagnosis (TFOD) is a concept to clarify the cause of tear film instability by tear film, and tear film-oriented treatment (TFOT) is a concept to treat dry eye disease by replacing the lacking components of the tear film layer based on the TFOD. In TFOD, the fluorescein breakup pattern of the tear film is important, and the subtype of dry eye can be judged to some extent from the breakup patterns. Current noninvasive devices related to the dynamic analysis of the tear film and visual acuity enabled the diagnosis of dry eye, subtype analysis, and the extent of severity. In Asian countries, secretagogues represent the main treatment in TFOT. Since meibomian gland dysfunction is a factor that greatly affects the tear breakup time, its treatment is also essential in the dry eye treatment strategy. A newly discovered dry eye subtype is the short breakup time-type (BUT) of dry eye. The only abnormal finding in this disease is the short BUT, suggesting a relationship with ocular neuropathic pain and eye strain. Recently, data from many studies have accumulated which show that dry eye is a life-style disease. In addition to the treatment of dry eyes, it is becoming possible to prevent the onset by intervening with the daily habits, diet, exercise and sleep, etc. It has been pointed out that oxidative stress is also involved in the pathology of dry eye, and intervention is being carried out by improving diet and taking supplements. Future research will be needed to link clinical findings to the molecular biological findings in the tear film.
Collapse
Affiliation(s)
- Takashi Kojima
- Department of Ophthalmology, Keio University School of Medicine, Japan
| | - Murat Dogru
- Department of Ophthalmology, Keio University School of Medicine, Japan
| | - Motoko Kawashima
- Department of Ophthalmology, Keio University School of Medicine, Japan
| | - Shigeru Nakamura
- Department of Ophthalmology, Keio University School of Medicine, Japan
| | - Kazuo Tsubota
- Department of Ophthalmology, Keio University School of Medicine, Japan; Tsubota Laboratory, Inc., Tokyo, Japan.
| |
Collapse
|
11
|
Negishi K, Hayashi K, Kamiya K, Sato M, Bissen-Miyajima H, Negishi K, Hayashi K, Kamiya K, Sato M, Bissen-Miyajima H. Nationwide Prospective Cohort Study on Cataract Surgery With Multifocal Intraocular Lens Implantation in Japan. Am J Ophthalmol 2019; 208:133-144. [PMID: 31377282 DOI: 10.1016/j.ajo.2019.07.019] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Revised: 07/21/2019] [Accepted: 07/26/2019] [Indexed: 11/25/2022]
Abstract
PURPOSE To conduct a nationwide prospective cohort study of multifocal intraocular lens (mfIOL) implantation to determine clinical outcomes and patient satisfaction and assess factors affecting patient satisfaction. DESIGN Prospective, multicenter cohort study. METHODS Setting: institutional; patient population: a total of 1051 consecutive patients (1631 eyes) who underwent cataract surgery with mfIOL implantation at 65 Japanese institutions from January 2017 to June 2018. The inclusion criteria were patient age of 20 years and older and cataract surgery with mfIOL implantation. The exclusion criteria were the absence of informed consent, completed postoperative questionnaires, and no record of the IOL models implanted. OBSERVATION PROCEDURES the uncorrected and corrected distance visual acuities (UDVAs and CDVAs) at 5 m; uncorrected VAs at 50, 40, and 30 cm; and questionnaires regarding subjective visual symptoms, spectacle independence, and surgical satisfaction were assessed 3 months postoperatively. MAIN OUTCOME MEASURE odds ratios for the overall surgical satisfaction were computed for the preoperative/postoperative factors. RESULTS We analyzed data from 1384 eyes of 871 patients. The UDVAs and CDVAs, respectively, improved significantly at 3 months postoperatively. The intermediate and near VAs varied with the IOL models; 68.4% of patients were almost or totally spectacle-independent; 3.9% of patients reported surgical dissatisfaction. In patients implanted bilaterally with the same mfIOLs, postoperative blurred vision and/or decreased contrast was the most important factor in the overall surgical satisfaction. CONCLUSIONS MfIOLs provided good visual outcomes and high satisfaction rates in this large patient cohort. The difference in the outcomes with the extended depth-of-focus IOLs did not differ significantly from the bifocal IOLs. The postoperative blurred vision is important to the overall surgical satisfaction.
Collapse
|
12
|
Shortened Measurement Time of Functional Visual Acuity for Screening Visual Function. J Ophthalmol 2019; 2019:8950418. [PMID: 31583130 PMCID: PMC6754928 DOI: 10.1155/2019/8950418] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Revised: 06/02/2019] [Accepted: 06/17/2019] [Indexed: 11/25/2022] Open
Abstract
The functional visual acuity test which is the average of the visual acuities measured during a specific time frame (standard, 60 seconds) has been used recently to assess the visual function in various conditions. The availability of a shorter version of the functional visual acuity test promises to be patient friendly in that it is a simple screening test performed in a shorter period of time than the standard test. The results of measurements of the FVA test between the 30-second measurement time (short-version FVA test) and the standard 60-second measurement are compared, and the feasibility of the short-version FVA test instead of the standard FVA test is investigated. Twenty-eight healthy volunteers (25 men and 3 women) were enrolled in this prospective observational study. All subjects underwent measurement of the binocular distance-corrected visual acuity and the binocular distance-corrected FVA with the 60-second and 30-second measurement times. The interchangeability of the corrected-distance FVA, maximal VA, visual maintenance ratio, and average response time in the short-version and the standard FVA tests was evaluated using the Bland–Altman method, and the results showed agreements of the two tests except for the minimal VA. The short-version FVA test is equivalent to the standard method except for evaluating the visual acuity fluctuations and promises to be a simple visual screening test that can be performed in a shorter time.
Collapse
|
13
|
Association among Blink Rate, Changes in Ocular Surface Temperature, Tear Film Stability, and Functional Visual Acuity in Patients after Cataract Surgery. J Ophthalmol 2019; 2019:8189097. [PMID: 31531236 PMCID: PMC6721014 DOI: 10.1155/2019/8189097] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2019] [Revised: 06/17/2019] [Accepted: 07/27/2019] [Indexed: 11/18/2022] Open
Abstract
Purpose To investigate the association among the ocular surface temperature (OST), tear film stability, functional visual acuity (FVA), and blink rate in patients after cataract surgery. Methods We recruited 98 eyes of 69 patients (mean age, 73.7 ± 5.2 years) 1 month after phacoemulsification with implantation of acrylic intraocular lenses and assessed slit-lamp microscopy, corrected distance VA, FVA, noninvasive tear breakup time (NIBUT), and OST. We defined the changes in the OST from 0 to 10 seconds after eye opening as the ΔOST. We measured the FVA and blink rate using the FVA measurement system. We divided the patients into two groups based on tear film stability: stable tear film (NIBUT, >5.0 seconds) and unstable tear film (NIBUT, ≤5.0 seconds). We evaluated the differences between the two groups and the association between the blink rate and other clinical parameters. Results The unstable tear film group (56 eyes) had significantly (p < 0.0001, unpaired t-test) shorter NIBUTs than the stable tear film group (42 eyes). The ΔOSTs and blink rates were significantly (p < 0.0001) higher in the unstable tear film group than in the stable group. Linear single regression analysis showed that the ΔOST (r = −0.430, p < 0.0001), NIBUT (r = −0.392, p < 0.0001), and gender (r = −0.370, p=0.0002) were correlated significantly with the blink rate. Multiple regression analysis showed that the ΔOST independently contributed to the blink rate. Conclusions The frequency of blinks is associated with tear film stability in patients after cataract surgery. The blink rate may be useful for evaluating the tear film stability in clinical practice. The ΔOST should be an important contributing factor to the blink rate. [This trial is registered with UMIN000026970].
Collapse
|
14
|
Koh S, Inoue R, Sato S, Haruna M, Asonuma S, Nishida K. Quantification of accommodative response and visual performance in non-presbyopes wearing low-add contact lenses. Cont Lens Anterior Eye 2019; 43:226-231. [PMID: 31327577 DOI: 10.1016/j.clae.2019.07.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2019] [Revised: 07/15/2019] [Accepted: 07/15/2019] [Indexed: 12/22/2022]
Abstract
PURPOSE Digital eye strain encompasses a range of ocular and visual symptoms across all age groups. Recently, symptoms associated with accommodative or binocular vision stress have become a major problem, especially in young individuals. The purpose of this prospective, single-blinded study was to objectively quantify the accommodative response and visual performance of low-add soft contact lenses (CLs) in young non-presbyopic individuals. METHODS A daily disposable low-add bifocal design lens (low-add CL) was tested. It employs a centre-distance optical zone and peripheral zone with the added power of +0.50 D to support near vision. Sixteen subjects aged 20-39 years were enrolled in the study. Refractive state and accommodation were measured using an open-field autorefractor with three target vergences, namely, -0.20 D, -2.5 D, and -4.0 D. Binocular visual acuity at high (100%) and low (40%, 20%) contrast and reading ability were assessed. Monofocal soft CLs were used as controls. RESULTS Accommodative response with low-add CLs was significantly smaller than those with two monofocal CL wearing conditions, i.e., at 40 cm (2.5 D of stimulus) and 25 cm (4.0 D of stimulus) (all p < 0.05). The 20% contrast visual acuity at distance was significantly better with low-add CLs and second-time monofocal CLs compared to first-time monofocal CLs (all p < 0.05). The reading ability was not significantly different. CONCLUSIONS Quantification of accommodative response and visual performance demonstrated that using low-add CLs alleviated the accommodation under the near-vision condition, without sacrificing distance vision, in non-presbyopes.
Collapse
Affiliation(s)
- Shizuka Koh
- Department of Innovative Visual Science, Osaka University Graduate School of Medicine, Osaka, Japan; Department of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, Japan.
| | - Ryota Inoue
- Department of Innovative Visual Science, Osaka University Graduate School of Medicine, Osaka, Japan; SEED CO., LTD., Tokyo, Japan
| | - Shinnosuke Sato
- Department of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Mai Haruna
- Department of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Sanae Asonuma
- Department of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Kohji Nishida
- Department of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, Japan
| |
Collapse
|
15
|
Abstract
Measurement of tear film breakup time (TBUT) has become a standard diagnostic procedure in the dry eye clinic. Short TBUT-type dry eye is characterized by TBUT of less than 5 seconds and dry eye symptoms such as ocular fatigue or dryness; the importance of this type has recently been gaining prominence. Patients with this condition show no reduction in tear production and no staining of the ocular surface. The severity of symptoms is almost the same as in dry eye in which the ocular surface is stained with rose bengal or fluorescein. In addition to discomfort, patients suffer from decreased vision due to the unstable tear film, which can be attributed to the relative abnormality of the lipid layer, aqueous layer, and/or mucin layer. The diagnosis should be performed carefully on the basis of the patient's symptoms and the TBUT test, because the ocular surface appears normal and remains unstained.
Collapse
Affiliation(s)
- Kazuo Tsubota
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
| |
Collapse
|