1
|
Neves GS, Reis ZSN, Romanelli R, Batchelor J. Assessment of Skin Maturity by LED Light at Birth and Its Association With Lung Maturity: Clinical Trial Secondary Outcomes. JMIR BIOMEDICAL ENGINEERING 2023; 8:e52468. [PMID: 38875690 PMCID: PMC11041497 DOI: 10.2196/52468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 10/26/2023] [Accepted: 10/27/2023] [Indexed: 06/16/2024] Open
Abstract
BACKGROUND Clinicians face barriers when assessing lung maturity at birth due to global inequalities. Still, strategies for testing based solely on gestational age to predict the likelihood of respiratory distress syndrome (RDS) do not offer a comprehensive approach to addressing the challenge of uncertain outcomes. We hypothesize that a noninvasive assessment of skin maturity may indicate lung maturity. OBJECTIVE This study aimed to assess the association between a newborn's skin maturity and RDS occurrence. METHODS We conducted a case-control nested in a prospective cohort study, a secondary endpoint of a multicenter clinical trial. The study was carried out in 5 Brazilian urban reference centers for highly complex perinatal care. Of 781 newborns from the cohort study, 640 were selected for the case-control analysis. Newborns with RDS formed the case group and newborns without RDS were the controls. All newborns with other diseases exhibiting respiratory manifestations were excluded. Skin maturity was assessed from the newborn's skin over the sole by an optical device that acquired a reflection signal through an LED sensor. The device, previously validated, measured and recorded skin reflectance. Clinical data related to respiratory outcomes were gathered from medical records during the 72-hour follow-up of the newborn, or until discharge or death, whichever occurred first. The main outcome measure was the association between skin reflectance and RDS using univariate and multivariate binary logistic regression. Additionally, we assessed the connection between skin reflectance and factors such as neonatal intensive care unit (NICU) admission and the need for ventilatory support. RESULTS Out of 604 newborns, 470 (73.4%) were from the RDS group and 170 (26.6%) were from the control group. According to comparisons between the groups, newborns with RDS had a younger gestational age (31.6 vs 39.1 weeks, P<.001) and birth weight (1491 vs 3121 grams, P<.001) than controls. Skin reflectance was associated with RDS (odds ratio [OR] 0.982, 95% CI 0.979-0.985, R2=0.632, P<.001). This relationship remained significant when adjusted by the cofactors antenatal corticosteroid and birth weight (OR 0.994, 95% CI 0.990-0.998, R2=0.843, P<.001). Secondary outcomes also showed differences in skin reflectance. The mean difference was 0.219 (95% CI 0.200-0.238) between newborns that required ventilatory support versus those that did not and 0.223 (95% CI 0.205-0.241) between newborns that required NICU admission versus those that did not. Skin reflectance was associated with ventilatory support (OR 0.996, 95% CI 0.992-0.999, R2=0.814, P=.01) and with NICU admission (OR 0.994, 95% CI 0.990-0.998, R2=0.867, P=.004). CONCLUSIONS Our findings present a potential marker of lung immaturity at birth using the indirect method of skin assessment. Using the RDS clinical condition and a medical device, this study demonstrated the synchrony between lung and skin maturity. TRIAL REGISTRATION Registro Brasileiro de Ensaios Clínicos (ReBEC) RBR-3f5bm5; https://tinyurl.com/9fb7zrdb. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID) RR2-10.1136/bmjopen-2018-027442.
Collapse
Affiliation(s)
| | | | - Roberta Romanelli
- Faculty of Medicine, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil
| | - James Batchelor
- Faculty of Medicine, University of Southampton, Southampton, United Kingdom
| |
Collapse
|
2
|
Reis ZSN, Pappa GL, Nader PDJH, do Vale MS, Silveira Neves G, Vitral GLN, Mussagy N, Norberto Dias IM, Romanelli RMDC. Respiratory distress syndrome prediction at birth by optical skin maturity assessment and machine learning models for limited-resource settings: a development and validation study. Front Pediatr 2023; 11:1264527. [PMID: 38054190 PMCID: PMC10694507 DOI: 10.3389/fped.2023.1264527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Accepted: 10/23/2023] [Indexed: 12/07/2023] Open
Abstract
Background A handheld optical device was developed to evaluate a newborn's skin maturity by assessing the photobiological properties of the tissue and processing it with other variables to predict early neonatal prognosis related to prematurity. This study assessed the device's ability to predict respiratory distress syndrome (RDS). Methods To assess the device's utility we enrolled newborns at childbirth in six urban perinatal centers from two multicenter single-blinded clinical trials. All newborns had inpatient follow-up until 72 h of life. We trained supervised machine learning models with data from 780 newborns in a Brazilian trial and provided external validation with data from 305 low-birth-weight newborns from another trial that assessed Brazilian and Mozambican newborns. The index test measured skin optical reflection with an optical sensor and adjusted acquired values with clinical variables such as birth weight and prenatal corticoid exposition for lung maturity, maternal diabetes, and hypertensive disturbances. The performance of the models was evaluated using intrasample k-parts cross-validation and external validation in an independent sample. Results Models adjusting three predictors (skin reflection, birth weight, and antenatal corticoid exposure) or five predictors had a similar performance, including or not maternal diabetes and hypertensive diseases. The best global accuracy was 89.7 (95% CI: 87.4 to 91.8, with a high sensitivity of 85.6% (80.2 to 90.0) and specificity of 91.3% (95% CI: 88.7 to 93.5). The test correctly discriminated RDS newborns in external validation, with 82.3% (95% CI: 77.5 to 86.4) accuracy. Our findings demonstrate a new way to assess a newborn's lung maturity, providing potential opportunities for earlier and more effective care. Trial registration RBR-3f5bm5 (online access: http://www.ensaiosclinicos.gov.br/rg/RBR-3f5bm5/), and RBR-33mjf (online access: https://ensaiosclinicos.gov.br/rg/RBR-33rnjf/).
Collapse
Affiliation(s)
| | - Gisele Lobo Pappa
- Departamento de Ciência da Computação, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil
| | | | | | | | | | | | | | | |
Collapse
|
3
|
Reis ZSN, Romanelli RMDC, Guimarães RN, Gaspar JDS, Neves GS, do Vale MS, Nader PDJ, de Moura MDR, Vitral GLN, Dos Reis MAA, Pereira MMM, Marques PF, Nader SS, Harff AL, Beleza LDO, de Castro MEC, Souza RG, Pappa GL, de Aguiar RAPL. Newborn Skin Maturity Medical Device Validation for Gestational Age Prediction: Clinical Trial. J Med Internet Res 2022; 24:e38727. [PMID: 36069805 PMCID: PMC9494223 DOI: 10.2196/38727] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Revised: 07/04/2022] [Accepted: 07/25/2022] [Indexed: 11/26/2022] Open
Abstract
Background Early access to antenatal care and high-cost technologies for pregnancy dating challenge early neonatal risk assessment at birth in resource-constrained settings. To overcome the absence or inaccuracy of postnatal gestational age (GA), we developed a new medical device to assess GA based on the photobiological properties of newborns’ skin and predictive models. Objective This study aims to validate a device that uses the photobiological model of skin maturity adjusted to the clinical data to detect GA and establish its accuracy in discriminating preterm newborns. Methods A multicenter, single-blinded, and single-arm intention-to-diagnosis clinical trial evaluated the accuracy of a novel device for the detection of GA and preterm newborns. The first-trimester ultrasound, a second comparator ultrasound, and data regarding the last menstrual period (LMP) from antenatal reports were used as references for GA at birth. The new test for validation was performed using a portable multiband reflectance photometer device that assessed the skin maturity of newborns and used machine learning models to predict GA, adjusted for birth weight and antenatal corticosteroid therapy exposure. Results The study group comprised 702 pregnant women who gave birth to 781 newborns, of which 366 (46.9%) were preterm newborns. As the primary outcome, the GA as predicted by the new test was in line with the reference GA that was calculated by using the intraclass correlation coefficient (0.969, 95% CI 0.964-0.973). The paired difference between predicted and reference GAs was −1.34 days, with Bland-Altman limits of −21.2 to 18.4 days. As a secondary outcome, the new test achieved 66.6% (95% CI 62.9%-70.1%) agreement with the reference GA within an error of 1 week. This agreement was similar to that of comparator-LMP-GAs (64.1%, 95% CI 60.7%-67.5%). The discrimination between preterm and term newborns via the device had a similar area under the receiver operating characteristic curve (0.970, 95% CI 0.959-0.981) compared with that for comparator-LMP-GAs (0.957, 95% CI 0.941-0.974). In newborns with absent or unreliable LMPs (n=451), the intent-to-discriminate analysis showed correct preterm versus term classifications with the new test, which achieved an accuracy of 89.6% (95% CI 86.4%-92.2%), while the accuracy for comparator-LMP-GA was 69.6% (95% CI 65.3%-73.7%). Conclusions The assessment of newborn’s skin maturity (adjusted by learning models) promises accurate pregnancy dating at birth, even without the antenatal ultrasound reference. Thus, the novel device could add value to the set of clinical parameters that direct the delivery of neonatal care in birth scenarios where GA is unknown or unreliable. International Registered Report Identifier (IRRID) RR2-10.1136/bmjopen-2018-027442
Collapse
Affiliation(s)
- Zilma Silveira Nogueira Reis
- Health Informatics Center, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil.,Department of Gynecology and Obstetrics, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil.,Center for Artificial Intelligence, Innovation and Health, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil
| | | | | | - Juliano de Souza Gaspar
- Department of Gynecology and Obstetrics, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil
| | | | - Marynea Silva do Vale
- Maternal and Child Unit, University Hospital, Universidade Federal do Maranhão, São Luis, Brazil
| | | | | | | | | | | | - Patrícia Franco Marques
- Maternal and Child Unit, University Hospital, Universidade Federal do Maranhão, São Luis, Brazil
| | | | - Augusta Luize Harff
- University Hospital of Canoas, Universidade Luterana do Brasil, Canoas, Brazil
| | | | | | - Rayner Guilherme Souza
- Department of Gynecology and Obstetrics, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil
| | - Gisele Lobo Pappa
- Center for Artificial Intelligence, Innovation and Health, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil.,Computer Science Department, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil
| | | |
Collapse
|
4
|
de Souza IMF, Vitral GLN, Caliari MV, Reis ZSN. Association between the chronology of gestation and the morphometrical skin characteristics at childbirth: a development of predictive model. BMJ Health Care Inform 2021; 28:bmjhci-2021-100476. [PMID: 34876452 PMCID: PMC8655593 DOI: 10.1136/bmjhci-2021-100476] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Accepted: 11/10/2021] [Indexed: 12/11/2022] Open
Abstract
Objective The structural maturation of the skin is considered a potential marker of pregnancy dating. This study investigated the correlation between the morphometrical skin characteristics with the pregnancy chronology to propose models for predicting gestational age. Methods A cross-sectional analysis selected 35 corpses of newborns. The biopsy was performed up to 48 hours after death in the periumbilical abdomen, palm and sole regions. Pregnancy chronology was based on the obstetric ultrasound before 14 weeks. The dimensions of the skin layers, area of glands and connective fibrous tissue were measured with imaging software support. Univariate and multivariate regression models on morphometric values were used to predict gestational age. Results Gestational age at birth ranged from 20.3 to 41.2 weeks. Seventy-one skin specimens resulted in the analysis of 1183 digital histological images. The correlation between skin thickness and gestational age was positive and strong in both regions of the body. The highest univariate correlation between gestational age and skin thickness was using the epidermal layer dimensions, in palm (r=0.867, p<0.001). The multivariate modelling with the thickness of the abdominal epidermis, the dermis and the area of the sebaceous glands adjusted had the highest correlation with gestational age (r=0.99, p<0.001). Conclusion The thickness of the protective epidermal barrier is, in itself, a potential marker of pregnancy dating. However, sets of values obtained from skin morphometry enhanced the estimation of the gestational age. Such findings may support non-invasive image approaches to estimate pregnancy dating with various clinical applications.
Collapse
Affiliation(s)
| | | | - Marcelo Vidigal Caliari
- Department of General Pathology, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| | | |
Collapse
|
5
|
Reis Z, Vitral G, Guimarães R, Gaspar J, Colosimo E, Taunde S, Mussagy N, Rosado Santos R, Ayres-De-Campos D, Romanelli R. Premature or Small for Gestational Age Discrimination: International Multicenter Trial Protocol for Classification of the Low-Birth-Weight Newborn Through the Optical Properties of the Skin. JMIR Res Protoc 2020; 9:e16477. [PMID: 32673275 PMCID: PMC7388049 DOI: 10.2196/16477] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2019] [Revised: 04/09/2020] [Accepted: 05/06/2020] [Indexed: 12/02/2022] Open
Abstract
Background A low birth weight is an independent risk factor for adverse infant outcomes and a predictor of chronic disease in adulthood. In these situations, differentiating between prematurity and small for gestational age (SGA) or simultaneous conditions is essential to ensuring adequate care. Such diagnoses, however, depend on reliable pregnancy dating, which can be challenging in developing countries. A new medical optoelectronic device was developed to estimate gestational age (GA) at birth based on newborn skin reflection. Objective This study will aim to evaluate the device’s ability to detect prematurity or SGA, or both conditions simultaneously as well as predict short-term pulmonary complications in a cohort of low-birth-weight newborns. Methods This study protocol was designed for a multicenter cohort including referral hospitals in Brazil and Mozambique. Newborns weighing 500-2500 g will be eligible for inclusion with the best GA available, considering the limited resources of low-income countries. Comparator-GA is based on reliable last menstrual period dating or ultrasound assessment before 24 weeks’ gestation. Estimated GA at birth (Test-GA) will be calculated by applying a novel optoelectronic device to the newborn’s skin over the sole. The average difference between Test-GA and Comparator-GA will be analyzed, as will the percentage of newborns who are correctly diagnosed as preterm or SGA. In addition, in a nested case–control study, the accuracy of skin reflection in the prediction of prematurity-related respiratory problems will be evaluated. The estimated required sample size is 298 newborns. Results Teams of health professionals were trained, and standard operating procedures were developed following the good practice guidelines for the clinical investigation of medical devices for human participants. The first recruitment started in March 2019 in Brazil. Data collection is planned to end in December 2020, and the results should be available in March 2021. Conclusions The results of this clinical study have the potential to validate a new device to easily assess postnatal GA, supporting SGA identification when pregnancy dating is unreliable or unknown. Trial Registration ReBec: RBR-33rnjf; http://www.ensaiosclinicos.gov.br/rg/RBR-33rnjf/ International Registered Report Identifier (IRRID) DERR1-10.2196/16477
Collapse
Affiliation(s)
- Zilma Reis
- Faculty of Medicine, Universidade Federal de Minas Gerais, Brazil, Belo Horizonte, Brazil
| | - Gabriela Vitral
- Faculty of Medicine, Universidade Federal de Minas Gerais, Brazil, Belo Horizonte, Brazil
| | - Rodney Guimarães
- Faculty of Medicine, Universidade Federal de Minas Gerais, Brazil, Belo Horizonte, Brazil
| | - Juliano Gaspar
- Faculty of Medicine, Universidade Federal de Minas Gerais, Brazil, Belo Horizonte, Brazil
| | - Enrico Colosimo
- Statistics Department, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil
| | | | | | | | | | - Roberta Romanelli
- Faculty of Medicine, Universidade Federal de Minas Gerais, Brazil, Belo Horizonte, Brazil
| |
Collapse
|
6
|
Reis ZSN, Gaspar JDS, Vitral GLN, Abrantes VB, de-Souza IMF, Moreira MTS, Lopes Pessoa Aguiar RA. Quality of Pregnancy Dating and Obstetric Interventions During Labor: Retrospective Database Analysis. JMIR Pediatr Parent 2020; 3:e14109. [PMID: 32293572 PMCID: PMC7191349 DOI: 10.2196/14109] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2019] [Revised: 12/16/2019] [Accepted: 02/06/2020] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND The correct dating of pregnancy is critical to support timely decisions and provide obstetric care during birth. The early obstetric ultrasound assessment before 14 weeks is considered the best reference to assist in determining gestational age (GA), with an accuracy of ±5 to 7 days. However, this information is limited in many settings worldwide. OBJECTIVE The aim of this study is to analyze the association between the obstetric interventions during childbirth and the quality of GA determination, according to the first antenatal ultrasound assessment, which assisted the calculation. METHODS This is a hospital-based cohort study using medical record data of 2113 births at a perinatal referral center. The database was separated into groups and subgroups of analyses based on the reference used by obstetricians to obtain GA at birth. Maternal and neonatal characteristics, mode of delivery, oxytocin augmentation, and forceps delivery were compared between groups of pregnancies with GA determination at different reference points: obstetric ultrasound assessment 14 weeks, 20 weeks, and ≥20 weeks or without antenatal ultrasound (suboptimal dating). Ultrasound-based GA information was associated with outcomes between the interest groups using chi-square tests, odds ratios (OR) with 95% CI, or the Mann-Whitney statistical analysis. RESULTS The chance of nonspontaneous delivery was higher in pregnancies with 14 weeks ultrasound-based GA (OR 1.64, 95% CI 1.35-1.98) and 20 weeks ultrasound-based GA (OR 1.58, 95% CI 1.31-1.90) when compared to the pregnancies with ≥20 weeks ultrasound-based GA or without any antenatal ultrasound. The use of oxytocin for labor augmentation was higher for 14 weeks and 20 weeks ultrasound-based GA, OR 1.41 (95% CI 1.09-1.82) and OR 1.34 (95% CI 1.04-1.72), respectively, when compared to those suboptimally dated. Moreover, maternal blood transfusion after birth was more frequent in births with suboptimal ultrasound-based GA determination (20/657, 3.04%) than in the other groups (14 weeks ultrasound-based GA: 17/1163, 1.46%, P=.02; 20 weeks ultrasound-based GA: 25/1456, 1.71%, P=.048). Cesarean section rates between the suboptimal dating group (244/657, 37.13%) and the other groups (14 weeks: 475/1163, 40.84%, P=.12; 20 weeks: 584/1456, 40.10%, P=.20) were similar. In addition, forceps delivery rates between the suboptimal dating group (17/657, 2.6%) and the other groups (14 weeks: 42/1163, 3.61%, P=.24; 20 weeks: 46/1456, 3.16%, P=.47) were similar. Neonatal intensive care unit admission was more frequent in newborns with suboptimal dating (103/570, 18.07%) when compared with the other groups (14 weeks: 133/1004, 13.25%, P=.01; 20 weeks: 168/1263, 13.30%, P=.01), excluding stillbirths and major fetal malformations. CONCLUSIONS The present analysis highlighted relevant points of health care to improve obstetric assistance, confirming the importance of early access to technologies for pregnancy dating as an essential component of quality antenatal care.
Collapse
Affiliation(s)
| | | | | | - Vitor Barbosa Abrantes
- Center of Health Informatics, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil
| | | | | | | |
Collapse
|
7
|
Silva PC, Guimarães RN, Souza RG, Reis ZSN. A quantitative cross-sectional analysis of the melanin index in the skin of preterm newborns and its association with gestational age at birth. Skin Res Technol 2019; 26:356-361. [PMID: 31763716 PMCID: PMC7318316 DOI: 10.1111/srt.12810] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2019] [Accepted: 11/09/2019] [Indexed: 12/19/2022]
Abstract
BACKGROUND Estimation of gestational age (GA) is important to make timely decisions and provide appropriate neonatal care. Clinical maturity scales to estimate GA have used skin texture and color to assess maturity at birth facing situations of the uncertainty of pregnancy dating. The size and darkness of the areola around the nipple to grade skin characteristics are based on visual appearance. The melanin index (M-Index) is an optical skin parameter related to the melanin content in the tissue. This study is aimed to associate the M-Index of the skin with the GA. METHODS A cross-sectional study evaluated 80 newborns at birth. A photometer device quantified the skin pigmentation on the areolae, forearms, and soles. Paired average differences of M-Index were compared among the three body sites. The skin M-Indexes were compared between subgroups of newborns until 34 weeks or with 34 and more. RESULTS The skin over the areola had the highest values of M-Index compared with the forearm or sole areas (P < .001 for both). Infants with a GA between 34 and <37 weeks had higher M-Index values over the areola than the group with a GA with 24 to <34 weeks: 41.7 (8.9) and 38.3 (10.5) median (IQR), P = .005. CONCLUSIONS The measurable M-Index values have the potential to improve physical evaluation in assessing GA at birth.
Collapse
Affiliation(s)
- Paola Conceição Silva
- Faculty of Medicine, Postgraduate Program in Women's Health, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil
| | - Rodney Nascimento Guimarães
- Faculty of Medicine, Center of Health Informatics, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil
| | | | - Zilma Silveira Nogueira Reis
- Faculty of Medicine, Postgraduate Program in Women's Health, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil
| |
Collapse
|
8
|
Reis ZSN, Guimarães RN, Rego MAS, Maia de Castro Romanelli R, Gaspar JDS, Vitral GLN, Dos Reis MAA, Colósimo EA, Neves GS, Vale MS, Nader PDJH, de Moura MDR, de Aguiar RAPL. Prematurity detection evaluating interaction between the skin of the newborn and light: protocol for the preemie-test multicentre clinical trial in Brazilian hospitals to validate a new medical device. BMJ Open 2019; 9:e027442. [PMID: 30842119 PMCID: PMC6429838 DOI: 10.1136/bmjopen-2018-027442] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
INTRODUCTION Recognising prematurity is critical in order to attend to immediate needs in childbirth settings, guiding the extent of medical care provided for newborns. A new medical device has been developed to carry out the preemie-test, an innovative approach to estimate gestational age (GA), based on the photobiological properties of the newborn's skin. First, this study will validate the preemie-test for GA estimation at birth and its accuracy to detect prematurity. Second, the study intends to associate the infant's skin reflectance with lung maturity, as well as evaluate safety, precision and usability of a new medical device to offer a suitable product for health professionals during childbirth and in neonatal care settings. METHODS AND ANALYSIS Research protocol for diagnosis, single-group, single-blinding and single-arm multicenter clinical trial with a reference standard. Alive newborns, with 24 weeks or more of pregnancy age, will be enrolled during the first 24 hours of life. Sample size is 787 subjects. The primary outcome is the difference between the GA calculated by the photobiological neonatal skin assessment methodology and the GA calculated by the comparator antenatal ultrasound or reliable last menstrual period (LMP). Immediate complications caused by pulmonary immaturity during the first 72 hours of life will be associated with skin reflectance in a nested case-control study. ETHICS AND DISSEMINATION Each local independent ethics review board approved the trial protocol. The authors intend to share the minimal anonymised dataset necessary to replicate study findings. TRIAL REGISTRATION NUMBER RBR-3f5bm5.
Collapse
Affiliation(s)
- Zilma Silveira Nogueira Reis
- Gynecology and Obstetrics, Universidade Federal de Minas Gerais, Faculty of Medicine, Belo Horizonte, Minas Gerais, Brazil
- Health Informatics Center, Faculty of Medicine, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| | - Rodney Nascimento Guimarães
- Health Informatics Center, Faculty of Medicine, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| | | | | | - Juliano de Souza Gaspar
- Health Informatics Center, Faculty of Medicine, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| | - Gabriela Luiza Nogueira Vitral
- Doctoral Pediatrics Postgraduate Program, Faculty of Medicine, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| | | | | | | | - Marynea Silva Vale
- Pediatrics, Hospital Universitario da Universidade Federal do Maranhao, Sao Luis, Maranhão, Brazil
| | | | | | | |
Collapse
|
9
|
Vitral GLN, Aguiar RAPL, de Souza IMF, Rego MAS, Guimarães RN, Reis ZSN. Skin thickness as a potential marker of gestational age at birth despite different fetal growth profiles: A feasibility study. PLoS One 2018; 13:e0196542. [PMID: 29698511 PMCID: PMC5919437 DOI: 10.1371/journal.pone.0196542] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2018] [Accepted: 04/14/2018] [Indexed: 01/21/2023] Open
Abstract
BACKGROUND New methodologies to estimate gestational age (GA) at birth are demanded to face the limited access to obstetric ultrasonography and imprecision of postnatal scores. The study analyzed the correlation between neonatal skin thickness and pregnancy duration. Secondarily, it investigated the influence of fetal growth profiles on tissue layer dimensions. METHODS AND FINDINGS In a feasibility study, 222 infants selected at a term-to-preterm ratio of 1:1 were assessed. Reliable information on GA was based on the early ultrasonography-based reference. The thicknesses of the epidermal and dermal skin layers were examined using high-frequency ultrasonography. We scanned the skin over the forearm and foot plantar surface of the newborns. A multivariate regression model was adjusted to determine the correlation of GA with skin layer dimensions. The best model to correlate skin thickness with GA was fitted using the epidermal layer on the forearm site, adjusted to cofactors, as follows: Gestational age (weeks) = -28.0 + 12.8 Ln (Thickness) - 4.4 Incubator staying; R2 = 0.604 (P<0.001). In this model, the constant value for the standard of fetal growth was statistically null. The dermal layer thickness on the forearm and plantar surfaces had a negative moderate linear correlation with GA (R = -0.370, P<0.001 and R = -0.421, P<0.001, respectively). The univariate statistical analyses revealed the influence of underweight and overweight profiles on neonatal skin thickness at birth. Of the 222 infants, 53 (23.9%) had inappropriate fetal growths expected for their GA. Epidermal thickness was not fetal growth standard dependent as follows: 172.2 (19.8) μm for adequate for GA, 171.4 (20.6) μm for SGA, and 177.7 (15.2) μm for LGA (P = 0.525, mean [SD] on the forearm). CONCLUSIONS The analysis highlights a new opportunity to relate GA at birth to neonatal skin layer thickness. As this parameter was not influenced by the standard of fetal growth, skin maturity can contribute to clinical applications.
Collapse
Affiliation(s)
- Gabriela Luiza Nogueira Vitral
- Postgraduation Program of Women’s Health, Faculty of Medicine, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| | - Regina Amélia P. Lopes Aguiar
- Postgraduation Program of Women’s Health, Faculty of Medicine, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
- Department of Gynecology and Obstetrics, Faculty of Medicine, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| | - Ingrid Michelle Fonseca de Souza
- Postgraduation Program of Women’s Health, Faculty of Medicine, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| | - Maria Albertina Santiago Rego
- Department of Pediatrics, Faculty of Medicine, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| | - Rodney Nascimento Guimarães
- Postgraduation Program of Women’s Health, Faculty of Medicine, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
- Department of Gynecology and Obstetrics, Faculty of Medicine, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| | - Zilma Silveira Nogueira Reis
- Postgraduation Program of Women’s Health, Faculty of Medicine, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
- Department of Gynecology and Obstetrics, Faculty of Medicine, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| |
Collapse
|