Vogt I, Engel K, Schlünz A, Kowal R, Hensen B, Gutberlet M, Wacker F, Rose G. MRI-compatible abdomen phantom to mimic respiratory-triggered organ movement while performing needle-based interventions. Int J Comput Assist Radiol Surg 2024; 19:2329-2338. [PMID: 38839726 PMCID: PMC11607006 DOI: 10.1007/s11548-024-03188-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Accepted: 05/14/2024] [Indexed: 06/07/2024]
Abstract
PURPOSE In vivo studies are often required to prove the functionality and safety of medical devices. Clinical trials are costly and complex, adding to ethical scrutiny of animal testing. Anthropomorphic phantoms with versatile functionalities can overcome these issues with regard to medical education or an effective development of assistance systems during image-guided interventions (e.g., robotics, navigation/registration algorithms). In this work, an MRI-compatible and customizable motion phantom is presented to mimic respiratory-triggered organ movement as well as human anatomy. METHODS For this purpose, polyvinyl alcohol cryogel (PVA-C) was the foundation for muscles, liver, kidneys, tumors, and remaining abdominal tissue in different sizes of the abdominal phantom body (APB) with the ability to mimic human tissue in various properties. In addition, a semi-flexible rib cage was 3D-printed. The motion unit (MU) with an electromagnetically shielded stepper motor and mechanical extensions simulated a respiration pattern to move the APB. RESULTS Each compartment of the APB complied the relaxation times, dielectricity, and elasticity of human tissue. It showed resistance against mold and provided a resealable behavior after needle punctures. During long-term storage, the APB had a weight loss of 2.3%, followed by changes to relaxation times of 9.3% and elasticity up to 79%. The MU was able to physiologically appropriately mimic the organ displacement without reducing the MRI quality. CONCLUSION This work presents a novel modularizable and low-cost PVA-C based APB to mimic fundamental organ motion. Beside a further organ motion analysis, an optimization of APB's chemical composition is needed to ensure a realistic motion simulation and reproducible long-term use. This phantom enhances diverse and varied training environments for prospective physicians as well as effective R&D of medical devices with the possibility to reduce in vivo experiments.
Collapse
Affiliation(s)
- Ivan Vogt
- Research Campus STIMULATE, Otto von Guericke University, Magdeburg, Germany.
- Faculty of Electrical Engineering and Information Technology, Otto von Guericke University, Magdeburg, Germany.
| | - Katja Engel
- Research Campus STIMULATE, Otto von Guericke University, Magdeburg, Germany
- Faculty of Electrical Engineering and Information Technology, Otto von Guericke University, Magdeburg, Germany
| | - Anton Schlünz
- Research Campus STIMULATE, Otto von Guericke University, Magdeburg, Germany
- Faculty of Electrical Engineering and Information Technology, Otto von Guericke University, Magdeburg, Germany
| | - Robert Kowal
- Research Campus STIMULATE, Otto von Guericke University, Magdeburg, Germany
- Faculty of Electrical Engineering and Information Technology, Otto von Guericke University, Magdeburg, Germany
| | - Bennet Hensen
- Research Campus STIMULATE, Otto von Guericke University, Magdeburg, Germany
- Institute of Diagnostics and Interventional Radiology, Hannover Medical School, Hannover, Germany
| | - Marcel Gutberlet
- Research Campus STIMULATE, Otto von Guericke University, Magdeburg, Germany
- Institute of Diagnostics and Interventional Radiology, Hannover Medical School, Hannover, Germany
| | - Frank Wacker
- Research Campus STIMULATE, Otto von Guericke University, Magdeburg, Germany
- Institute of Diagnostics and Interventional Radiology, Hannover Medical School, Hannover, Germany
| | - Georg Rose
- Research Campus STIMULATE, Otto von Guericke University, Magdeburg, Germany
- Faculty of Electrical Engineering and Information Technology, Otto von Guericke University, Magdeburg, Germany
| |
Collapse
|
2
|
Park YG, Jo JH, Lee JK, Kim JM, Lee SJ, Kim HY. Biomechanical comparison of bone staple fixation methods with suture material for median sternotomy closure using 3D-printed bone models. N Z Vet J 2024; 72:265-274. [PMID: 38777331 DOI: 10.1080/00480169.2024.2350432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Accepted: 04/21/2024] [Indexed: 05/25/2024]
Abstract
AIM To compare the biomechanical properties of three different sternal closure techniques in a 3D-printed bone model of a sternum from a 30-kg dog. METHODS Median sternotomy was performed on a total of 90 three-dimensional (3D) copies of a polycarbonate (PC) model of a sternum, generated from the CT images of the sternum of a 30-kg German Shepherd dog. Three different methods were used to repair the sternotomies: polydioxanone suture (group PDS, n = 30), stainless steel bone staples (group SS, n = 30), and nitinol bone staples (group NS, n = 30). Each repair method was tested by applying tensile force in one of three ways (longitudinally, laterally, or torsionally) resulting in a sample size of n = 10 for each repair method-loading combination. In all experiments, the loads at 1-mm and 2-mm gap formation, failure, and the displacement at the failure point were measured. RESULTS In lateral distraction and longitudinal shear tests, NS and SS staple repairs required application of significantly greater force than PDS across all displacement criteria (1 and 2 mm). NS exhibited significantly greater failure load than PDS. In torsion tests, NS required significantly greater application of force compared to SS or PDS at all displacement criteria (1 and 2 mm) and exhibited a greater failure load than PDS. In terms of displacement at failure point, PDS suture showed more displacement than SS or NS across all experiments (laterally, longitudinally, torsionally). CONCLUSIONS In this study, bone staples were mechanically superior to PDS suture in median sternotomy closure using 3D-printed bone model in terms of 1-mm, 2-mm displacement loads, and displacement at failure. NS had a higher failure load than PDS under lateral, longitudinal, and torsional distraction. CLINICAL RELEVANCE These study results imply that bone staples can be considered as an alternative surgical method for median sternotomy closure in dogs.
Collapse
Affiliation(s)
- Y G Park
- College of Veterinary Medicine, Konkuk University, Seoul, Republic of Korea
| | - J H Jo
- College of Veterinary Medicine, Konkuk University, Seoul, Republic of Korea
| | - J K Lee
- College of Veterinary Medicine, Konkuk University, Seoul, Republic of Korea
| | - J M Kim
- College of Veterinary Medicine, Konkuk University, Seoul, Republic of Korea
| | - S J Lee
- College of Veterinary Medicine, Konkuk University, Seoul, Republic of Korea
| | - H Y Kim
- College of Veterinary Medicine, Konkuk University, Seoul, Republic of Korea
| |
Collapse
|
3
|
Wang X, Mu M, Yan J, Han B, Ye R, Guo G. 3D printing materials and 3D printed surgical devices in oral and maxillofacial surgery: design, workflow and effectiveness. Regen Biomater 2024; 11:rbae066. [PMID: 39169972 PMCID: PMC11338467 DOI: 10.1093/rb/rbae066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2024] [Revised: 05/14/2024] [Accepted: 06/02/2024] [Indexed: 08/23/2024] Open
Abstract
Oral and maxillofacial surgery is a specialized surgical field devoted to diagnosing and managing conditions affecting the oral cavity, jaws, face and related structures. In recent years, the integration of 3D printing technology has revolutionized this field, offering a range of innovative surgical devices such as patient-specific implants, surgical guides, splints, bone models and regenerative scaffolds. In this comprehensive review, we primarily focus on examining the utility of 3D-printed surgical devices in the context of oral and maxillofacial surgery and evaluating their efficiency. Initially, we provide an insightful overview of commonly utilized 3D-printed surgical devices, discussing their innovations and clinical applications. Recognizing the pivotal role of materials, we give consideration to suitable biomaterials and printing technology of each device, while also introducing the emerging fields of regenerative scaffolds and bioprinting. Furthermore, we delve into the transformative impact of 3D-printed surgical devices within specific subdivisions of oral and maxillofacial surgery, placing particular emphasis on their rejuvenating effects in bone reconstruction, orthognathic surgery, temporomandibular joint treatment and other applications. Additionally, we elucidate how the integration of 3D printing technology has reshaped clinical workflows and influenced treatment outcomes in oral and maxillofacial surgery, providing updates on advancements in ensuring accuracy and cost-effectiveness in 3D printing-based procedures.
Collapse
Affiliation(s)
- Xiaoxiao Wang
- State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan 610041, China
- Department of Biotherapy, State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Min Mu
- Department of Biotherapy, State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Jiazhen Yan
- School of Mechanical Engineering, Sichuan University, Chengdu, Sichuan 610065, China
| | - Bo Han
- School of Pharmacy, Shihezi University, and Key Laboratory of Xinjiang Phytomedicine Resource and Utilization, Ministry of Education, Shihezi, 832002, China, Shihezi 832002, China
| | - Rui Ye
- State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan 610041, China
| | - Gang Guo
- Department of Biotherapy, State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| |
Collapse
|
4
|
Wang X, Shujaat S, Shaheen E, Jacobs R. Quality and haptic feedback of three-dimensionally printed models for simulating dental implant surgery. J Prosthet Dent 2024; 131:660-667. [PMID: 35513918 DOI: 10.1016/j.prosdent.2022.02.027] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Revised: 02/20/2022] [Accepted: 02/21/2022] [Indexed: 11/29/2022]
Abstract
STATEMENT OF PROBLEM A model offering anatomic replication and haptic feedback similar to that of real bone is essential for hands-on surgical dental implant training. Patient-specific skeletal models can be produced with 3-dimensional (3D) printing, but whether these models can offer optimal haptic feedback for simulating implant surgery is unknown. PURPOSE The purpose of this trial was to compare the haptic feedback of different 3D printed models for simulating dental implant surgery. MATERIAL AND METHODS A cone beam computed tomography image of a 60-year-old man with a partially edentulous mandible was manipulated to segment the mandible and isolated from the rest of the scan. Three-dimensional models were printed with 6 different printers and materials: material jetting-based printer (MJ, acrylic-based resin); digital light processing-based printer (DLP, acrylic-based resin); fused filament fabrication-based printer (FFF1, polycarbonate filament; FFF2, polylactic acid filament); stereolithography-based printer (SLA, acrylic-based resin); and selective laser sintering-based printer (SLS, polyamide filament). Five experienced maxillofacial surgeons performed a simulated implant surgery on the models. A 5-point Likert scale questionnaire was established to assess the haptic feedback. The Friedman test and cumulative logit models were applied to evaluate differences among the models (α=.05). RESULTS The median score for drilling perception and implant insertion was highest for the MJ-based model and lowest for the SLS-based model. In relation to the drill chips, a median score of ≥3 was observed for all models. The score for corticotrabecular transition was highest for the MJ-based model and lowest for the FFF2-based model. Overall, the MJ-based model offered the highest score compared with the other models. CONCLUSIONS The 3D printed model with MJ technology and acrylic-based resin provided the best haptic feedback for performing implant surgery. However, none of the models were able to completely replicate the haptic perception of real bone.
Collapse
Affiliation(s)
- Xiaotong Wang
- Doctoral Candidate, OMFS-IMPATH Research Group, Department of Imaging & Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium; Clinical Surgeon, Department of Oral and Maxillofacial Surgery, The First Affiliated Hospital of Harbin Medical University, Harbin, China
| | - Sohaib Shujaat
- Postdoctoral Researcher, OMFS-IMPATH Research Group, Department of Imaging & Pathology, Faculty of Medicine, KU Leuven & Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.
| | - Eman Shaheen
- Clinical Engineer, OMFS-IMPATH Research Group, Department of Imaging & Pathology, Faculty of Medicine, KU Leuven & Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Reinhilde Jacobs
- Professor, OMFS-IMPATH Research Group, Department of Imaging & Pathology, Faculty of Medicine, KU Leuven & Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium; Professor, Department of Dental Medicine, Karolinska Institute, Stockholm, Sweden.
| |
Collapse
|
5
|
Díaz-Regañón D, Mendaza-De Cal R, García-Sancho M, Rodríguez-Franco F, Sainz Á, Rodriguez-Quiros J, Rojo C. Canine Upper Digestive Tract 3D Model: Assessing Its Utility for Anatomy and Upper Endoscopy Learning. Animals (Basel) 2024; 14:1070. [PMID: 38612309 PMCID: PMC11010944 DOI: 10.3390/ani14071070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Revised: 03/28/2024] [Accepted: 03/29/2024] [Indexed: 04/14/2024] Open
Abstract
A teaching strategy using 3D-printed models of the canine upper digestive tract (UDT) for anatomy demonstration and upper endoscopy instruction was evaluated. The canine UDT (esophagus-stomach-duodenum) was scanned and 3D-printed molds were manufactured using silicone casting. First-year students were introduced to these 3D models in practical sessions alongside real specimens. Simultaneously, fifth-year students were trained in endoscope handling and anatomical recognition using 3D specimens. Both groups completed an anonymous survey. Results showed that overall, first-year (n = 93) and fifth-year (n = 45) students agreed or strongly agreed that the 3D-printed model was effective for learning purposes. In summary, first-year students highlighted an improved understanding of size, volume, topography, and easier manipulation of the 3D model compared to fresh specimens. Fifth-year students were more enthusiastic, finding the 3D model valuable for spatial vision and clinical training. While both groups were against completely replacing the natural UDT with the 3D model, first-year students were more hesitant. These findings suggest that the 3D model of the canine UDT is an effective tool for hands-on training in clinical endoscopy and a valuable, albeit complementary, resource for teaching anatomy and topography.
Collapse
Affiliation(s)
- David Díaz-Regañón
- Department of Animal Medicine and Surgery, College of Veterinary Medicine, Complutense University of Madrid, Avda. Puerta de Hierro s/n, 28040 Madrid, Spain; (M.G.-S.); (F.R.-F.); (Á.S.); (J.R.-Q.)
| | - Rosa Mendaza-De Cal
- Departmental Section of Anatomy and Embryology, College of Veterinary Medicine, Complutense University of Madrid, Avda. Puerta de Hierro s/n, 28040 Madrid, Spain;
| | - Mercedes García-Sancho
- Department of Animal Medicine and Surgery, College of Veterinary Medicine, Complutense University of Madrid, Avda. Puerta de Hierro s/n, 28040 Madrid, Spain; (M.G.-S.); (F.R.-F.); (Á.S.); (J.R.-Q.)
| | - Fernando Rodríguez-Franco
- Department of Animal Medicine and Surgery, College of Veterinary Medicine, Complutense University of Madrid, Avda. Puerta de Hierro s/n, 28040 Madrid, Spain; (M.G.-S.); (F.R.-F.); (Á.S.); (J.R.-Q.)
| | - Ángel Sainz
- Department of Animal Medicine and Surgery, College of Veterinary Medicine, Complutense University of Madrid, Avda. Puerta de Hierro s/n, 28040 Madrid, Spain; (M.G.-S.); (F.R.-F.); (Á.S.); (J.R.-Q.)
| | - Jesus Rodriguez-Quiros
- Department of Animal Medicine and Surgery, College of Veterinary Medicine, Complutense University of Madrid, Avda. Puerta de Hierro s/n, 28040 Madrid, Spain; (M.G.-S.); (F.R.-F.); (Á.S.); (J.R.-Q.)
| | - Concepción Rojo
- Departmental Section of Anatomy and Embryology, College of Veterinary Medicine, Complutense University of Madrid, Avda. Puerta de Hierro s/n, 28040 Madrid, Spain;
| |
Collapse
|
6
|
Benca E, Eckhart B, Stoegner A, Unger E, Bittner-Frank M, Strassl A, Gahleitner C, Hirtler L, Windhager R, Hobusch GM, Moscato F. Dimensional accuracy and precision and surgeon perception of additively manufactured bone models: effect of manufacturing technology and part orientation. 3D Print Med 2024; 10:5. [PMID: 38376810 PMCID: PMC10877873 DOI: 10.1186/s41205-024-00203-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Accepted: 01/29/2024] [Indexed: 02/21/2024] Open
Abstract
BACKGROUND Additively manufactured (AM) anatomical bone models are primarily utilized for training and preoperative planning purposes. As such, they must meet stringent requirements, with dimensional accuracy being of utmost importance. This study aimed to evaluate the precision and accuracy of anatomical bone models manufactured using three different AM technologies: digital light processing (DLP), fused deposition modeling (FDM), and PolyJetting (PJ), built in three different part orientations. Additionally, the study sought to assess surgeons' perceptions of how well these models mimic real bones in simulated osteosynthesis. METHODS Computer-aided design (CAD) models of six human radii were generated from computed tomography (CT) imaging data. Anatomical models were then manufactured using the three aforementioned technologies and in three different part orientations. The surfaces of all models were 3D-scanned and compared with the original CAD models. Furthermore, an anatomical model of a proximal femur including a metastatic lesion was manufactured using the three technologies, followed by (mock) osteosynthesis performed by six surgeons on each type of model. The surgeons' perceptions of the quality and haptic properties of each model were assessed using a questionnaire. RESULTS The mean dimensional deviations from the original CAD model ranged between 0.00 and 0.13 mm with maximal inaccuracies < 1 mm for all models. In surgical simulation, PJ models achieved the highest total score on a 5-point Likert scale ranging from 1 to 5 (with 1 and 5 representing the lowest and highest level of agreement, respectively), (3.74 ± 0.99) in the surgeons' perception assessment, followed by DLP (3.41 ± 0.99) and FDM (2.43 ± 1.02). Notably, FDM was perceived as unsuitable for surgical simulation, as the material melted during drilling and sawing. CONCLUSIONS In conclusion, the choice of technology and part orientation significantly influenced the accuracy and precision of additively manufactured bone models. However, all anatomical models showed satisfying accuracies and precisions, independent of the AM technology or part orientation. The anatomical and functional performance of FDM models was rated by surgeons as poor.
Collapse
Affiliation(s)
- Emir Benca
- Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Währinger Gürtel 18-20, Vienna, 1090, Austria.
| | - Barbara Eckhart
- Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Währinger Gürtel 18-20, Vienna, 1090, Austria
| | - Alexander Stoegner
- Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Währinger Gürtel 18-20, Vienna, 1090, Austria
| | - Ewald Unger
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Martin Bittner-Frank
- Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Währinger Gürtel 18-20, Vienna, 1090, Austria
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Andreas Strassl
- Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Claudia Gahleitner
- Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Währinger Gürtel 18-20, Vienna, 1090, Austria
| | - Lena Hirtler
- Center for Anatomy and Cell Biology, Medical University of Vienna, Vienna, Austria
| | - Reinhard Windhager
- Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Währinger Gürtel 18-20, Vienna, 1090, Austria
| | - Gerhard M Hobusch
- Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Währinger Gürtel 18-20, Vienna, 1090, Austria
| | - Francesco Moscato
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
- Ludwig Boltzmann Institute for Cardiovascular Research, Vienna, Austria
- Austrian Cluster for Tissue Regeneration, Vienna, Austria
| |
Collapse
|
7
|
Brumpt E, Bertin E, Tatu L, Louvrier A. 3D printing as a pedagogical tool for teaching normal human anatomy: a systematic review. BMC MEDICAL EDUCATION 2023; 23:783. [PMID: 37864193 PMCID: PMC10589929 DOI: 10.1186/s12909-023-04744-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Accepted: 10/03/2023] [Indexed: 10/22/2023]
Abstract
BACKGROUND Three-dimensional-printed anatomical models (3DPAMs) appear to be a relevant tool due to their educational value and their feasibility. The objectives of this review were to describe and analyse the methods utilised for creating 3DPAMs used in teaching human anatomy and for evaluating its pedagogical contribution. METHODS An electronic search was conducted on PubMed using the following terms: education, school, learning, teaching, learn, teach, educational, three-dimensional, 3D, 3-dimensional, printing, printed, print, anatomy, anatomical, anatomically, and anatomic. Data retrieved included study characteristics, model design, morphological evaluation, educational performance, advantages, and disadvantages. RESULTS Of the 68 articles selected, the cephalic region was the most studied (33 articles); 51 articles mentioned bone printing. In 47 articles, the 3DPAM was designed from CT scans. Five printing processes were listed. Plastic and its derivatives were used in 48 studies. The cost per design ranged from 1.25 USD to 2800 USD. Thirty-seven studies compared 3DPAM to a reference model. Thirty-three articles investigated educational performance. The main advantages were visual and haptic qualities, effectiveness for teaching, reproducibility, customizability and manipulability, time savings, integration of functional anatomy, better mental rotation ability, knowledge retention, and educator/student satisfaction. The main disadvantages were related to the design: consistency, lack of detail or transparency, overly bright colours, long printing time, and high cost. CONCLUSION This systematic review demonstrates that 3DPAMs are feasible at a low cost and effective for teaching anatomy. More realistic models require access to more expensive 3D printing technologies and substantially longer design time, which would greatly increase the overall cost. Choosing an appropriate image acquisition modality is key. From a pedagogical viewpoint, 3DPAMs are effective tools for teaching anatomy, positively impacting the learning outcomes and satisfaction level. The pedagogical effectiveness of 3DPAMs seems to be best when they reproduce complex anatomical areas, and they are used by students early in their medical studies.
Collapse
Affiliation(s)
- Eléonore Brumpt
- University of Franche-Comté, 19 rue Ambroise Paré, Besançon, 25000, France.
- Radiologie, CHU de Besançon, Besançon, 25000, France.
- Laboratoire Nano Médecine, Imagerie, Thérapeutique, EA 4662, University of Franche-Comté, 16 Route de Gray, Besançon, F-25000, France.
- Anatomy Department, UFR Santé, 19 Rue Ambroise Paré, CS 71806, Besançon, F25030, France.
| | - Eugénie Bertin
- University of Franche-Comté, 19 rue Ambroise Paré, Besançon, 25000, France
- Chirurgie Maxillo-Faciale, Stomatologie Et Odontologie Hospitalière, CHU de Besançon, Besançon, 25000, France
| | - Laurent Tatu
- University of Franche-Comté, 19 rue Ambroise Paré, Besançon, 25000, France
- Neurologie, CHU de Besançon, Besançon, 25000, France
- Laboratoire de Neurosciences Intégratives Et Cliniques, University Franche-Comté, EA 481, Besançon, F-25000, France
| | - Aurélien Louvrier
- University of Franche-Comté, 19 rue Ambroise Paré, Besançon, 25000, France
- Chirurgie Maxillo-Faciale, Stomatologie Et Odontologie Hospitalière, CHU de Besançon, Besançon, 25000, France
- Plateforme I3DM (Impression 3D Médicale), CHU Besançon, Besançon, 25000, France
| |
Collapse
|
8
|
Utilizing Additive Manufacturing to Produce Organ Mimics and Imaging Phantoms. SURGERIES 2023. [DOI: 10.3390/surgeries4010008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
The complex geometries and material properties necessary for generating accurate organ mimics require new procedures and methods to fully utilize current technologies. The increased accessibility of 3D printers, along with more specialized bioprinters, allow the creation of highly tunable models of various body parts. Three-dimensional printing can reduce lead-time on custom parts, produce structures based on imaging data in patients, and generate a test bench for novel surgical methods. This technical note will cover three unique case studes and offer insights for how 3D printing can be used for lab research. Each case follows a unique design process in comparison to traditional manufacturing workflows as they required significantly more iterative design. The strengths of different printing technologies, design choices, and structural/chemical requirements all influence the design process. Utilization of in-house manufacturing allows for greater flexibility and lower lead-times for novel research applications. Detailed discussions of these design processes will help reduce some of the major barriers to entry for these technologies and provide options for researchers working in the field.
Collapse
|
9
|
Mendonça CJA, Guimarães RMDR, Pontim CE, Gasoto SC, Setti JAP, Soni JF, Schneider B. An Overview of 3D Anatomical Model Printing in Orthopedic Trauma Surgery. J Multidiscip Healthc 2023; 16:875-887. [PMID: 37038452 PMCID: PMC10082616 DOI: 10.2147/jmdh.s386406] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 12/09/2022] [Indexed: 04/12/2023] Open
Abstract
Introduction 3D object printing technology is a resource increasingly used in medicine in recent years, mainly incorporated in surgical areas like orthopedics. The models made by 3D printing technology provide surgeons with an accurate analysis of complex anatomical structures, allowing the planning, training, and surgery simulation. In orthopedic surgery, this technique is especially applied in oncological surgeries, bone, and joint reconstructions, and orthopedic trauma surgeries. In these cases, it is possible to prototype anatomical models for surgical planning, simulating, and training, besides printing of instruments and implants. Purpose The purpose of this paper is to describe the acquisition and processing from computed tomography images for 3D printing, to describe modeling and the 3D printing process of the biomodels in real size. This paper highlights 3D printing with the applicability of the 3D biomodels in orthopedic surgeries and shows some examples of surgical planning in orthopedic trauma surgery. Patients and Methods Four examples were selected to demonstrate the workflow and rationale throughout the process of planning and printing 3D models to be used in a variety of situations in orthopedic trauma surgeries. In all cases, the use of 3D modeling has impacted and improved the final treatment strategy. Conclusion The use of the virtual anatomical model and the 3D printed anatomical model with the additive manufacturing technology proved to be effective and useful in planning and performing the surgical treatment of complex articular fractures, allowing surgical planning both virtual and with the 3D printed anatomical model, besides being useful during the surgical time as a navigation instrument.
Collapse
Affiliation(s)
- Celso Junio Aguiar Mendonça
- Musculoskeletal System Unit, Hospital of Federal University of Paraná, Curitiba, Paraná, Brazil
- Postgraduate Program in Electrical Engineering and Industrial Informatics, Hospital of the Federal University of Paraná, Curitiba, Paraná, Brazil
- Correspondence: Celso Junio Aguiar Mendonça, Postgraduate Program in Electrical Engineering and Industrial Informatics – CPGEI, Federal Technological University of Paraná – UTFPR, Av. Sete de Setembro, 3165 – Rebouças, Curitiba, Paraná, 80230-901, Brazil, Tel +55 41 999973900, Email
| | - Ricardo Munhoz da Rocha Guimarães
- Cajuru University Hospital, Pontifical Catholic University of Paraná, Curitiba, Paraná, Brazil
- Postgraduate Program in Biomedical Engineering, Hospital of the Federal University of Paraná, Curitiba, Paraná, Brazil
| | - Carlos Eduardo Pontim
- Postgraduate Program in Biomedical Engineering, Hospital of the Federal University of Paraná, Curitiba, Paraná, Brazil
| | - Sidney Carlos Gasoto
- Postgraduate Program in Electrical Engineering and Industrial Informatics, Hospital of the Federal University of Paraná, Curitiba, Paraná, Brazil
| | - João Antonio Palma Setti
- Postgraduate Program in Biomedical Engineering, Hospital of the Federal University of Paraná, Curitiba, Paraná, Brazil
| | - Jamil Faissal Soni
- Musculoskeletal System Unit, Hospital of Federal University of Paraná, Curitiba, Paraná, Brazil
- Cajuru University Hospital, Pontifical Catholic University of Paraná, Curitiba, Paraná, Brazil
| | - Bertoldo Schneider
- Postgraduate Program in Electrical Engineering and Industrial Informatics, Hospital of the Federal University of Paraná, Curitiba, Paraná, Brazil
- Postgraduate Program in Biomedical Engineering, Hospital of the Federal University of Paraná, Curitiba, Paraná, Brazil
| |
Collapse
|
10
|
Novak JI, Maclachlan LR, Desselle MR, Haskell N, Fitzgerald K, Redmond M. What Qualities are Important for 3D Printed Neurosurgical Training Models? A Survey of Clinicians and Other Health Professionals Following an Interactive Exhibition. ANNALS OF 3D PRINTED MEDICINE 2022. [DOI: 10.1016/j.stlm.2022.100060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|
11
|
James J, Irace AL, Gudis DA, Overdevest JB. Simulation training in endoscopic skull base surgery: A scoping review. World J Otorhinolaryngol Head Neck Surg 2022; 8:73-81. [PMID: 35619934 PMCID: PMC9126166 DOI: 10.1002/wjo2.11] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2021] [Accepted: 09/22/2021] [Indexed: 01/16/2023] Open
Abstract
Objective Methods Results Conclusions
Collapse
Affiliation(s)
- Joel James
- City University of New York School of Medicine New York New York USA
| | - Alexandria L. Irace
- Department of Otolaryngology‐Head and Neck Surgery, Columbia University Vagelos College of Physicians and Surgeons Columbia University Irving Medical Center, New York‐Presbyterian Hospital New York New York USA
| | - David A. Gudis
- Department of Otolaryngology‐Head and Neck Surgery, Columbia University Vagelos College of Physicians and Surgeons Columbia University Irving Medical Center, New York‐Presbyterian Hospital New York New York USA
| | - Jonathan B. Overdevest
- Department of Otolaryngology‐Head and Neck Surgery, Columbia University Vagelos College of Physicians and Surgeons Columbia University Irving Medical Center, New York‐Presbyterian Hospital New York New York USA
| |
Collapse
|
12
|
Saleh Y, Piper R, Richard M, Jeyaretna S, Cosker T. Designing a 3D Printed Model of the Skull-Base: A Collaboration Between Clinicians and Industry. JOURNAL OF MEDICAL EDUCATION AND CURRICULAR DEVELOPMENT 2022; 9:23821205221080703. [PMID: 35280123 PMCID: PMC8905218 DOI: 10.1177/23821205221080703] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Accepted: 01/14/2022] [Indexed: 06/14/2023]
Abstract
INTRODUCTION The role of three dimensional (3D) printing in neurosurgical education is becoming increasingly common. Notably, 3D printing can simulate complex anatomical pathways that may be difficult to regularly and accurately reproduce in cadavers. One such example is the course of the facial nerve within the temporal bone and its relation to the labyrinth. This can aid pre-surgical planning and minimise surgical complications. Here we aim to develop a novel anatomically accurate model of the skull base which demonstrates key neuro vascular components and the course of the facial nerve within the temporal bone by developing a 3D printed model of the skull-base that can be used for medical education and pre-surgical planning. MATERIALS AND METHODS We utilised a combination of Computed Tomography (CT) and angiography scans to reconstruct the skull base and its vascular contents. Neural components were digitally incorporated under the guidance of the Oxford neurosurgical team and the anatomy department. The model was integrated and printed using polymer jetting. RESULTS The model was successfully printed, with all neurovascular components included. Notably we were able to highlight the intra-temporal course of the facial nerve by creating a bony window within the temporal bone. CONCLUSION Through a collaboration with industry and a multidisciplinary team, we were able to reproduce the base of the skull from patient neuro-imaging. Our model is both cost-effective, reproducible and can aid both medical students and neurosurgical trainees in their training/education.
Collapse
Affiliation(s)
- Youssuf Saleh
- Nuffield Department of Clinical Neurosciences, University of Oxford, UK
| | - Rory Piper
- Department of Neurosurgery, John Radcliffe Hospital, Oxford University Hospitals, UK
| | - Michael Richard
- 3D Life Prints, Nuffield Orthopaedic Centre, Oxford, United kingdom
| | - Sanjeeva Jeyaretna
- Department of Neurosurgery, John Radcliffe Hospital, Oxford University Hospitals, UK
| | - Thomas Cosker
- Department of Physiology Anatomy and Genetics, University of Oxford, UK
| |
Collapse
|
13
|
Properties and Characteristics of Three-Dimensional Printed Head Models Used in Simulation of Neurosurgical Procedures: A Scoping Review. World Neurosurg 2021; 156:133-146.e6. [PMID: 34571242 DOI: 10.1016/j.wneu.2021.09.079] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2021] [Revised: 09/15/2021] [Accepted: 09/16/2021] [Indexed: 10/20/2022]
Abstract
BACKGROUND Intracranial surgery can be complex and high risk. Safety, ethical and financial factors make training in the area challenging. Head model 3-dimensional (3D) printing is a realistic training alternative to patient and traditional means of cadaver and animal model simulation. OBJECTIVE To describe important factors relating to the 3D printing of human head models and how such models perform as simulators. METHODS Searches were performed in PubMed, the Cochrane Library, Scopus, and Web of Science. Articles were screened independently by 3 reviewers using Covidence software. Data items were collected under 5 categories: study information; printers and processes; head model specifics; simulation and evaluations; and costs and production times. RESULTS Forty articles published over the last 10 years were included in the review. A range of printers, printing methods, and substrates were used to create head models and tissue types. Complexity of the models ranged from sections of single tissue type (e.g., bone) to high-fidelity integration of multiple tissue types. Some models incorporated disease (e.g., tumors and aneurysms) and artificial physiology (e.g., pulsatile circulation). Aneurysm clipping, bone drilling, craniotomy, endonasal surgery, and tumor resection were the most commonly practiced procedures. Evaluations completed by those using the models were generally favorable. CONCLUSIONS The findings of this review indicate that those who practice surgery and surgical techniques on 3D-printed head models deem them to be valuable assets in cranial surgery training. Understanding how surgical simulation on such models affects surgical performance and patient outcomes, and considering cost-effectiveness, are important future research endeavors.
Collapse
|
14
|
Favier V, Subsol G, Duraes M, Captier G, Gallet P. Haptic Fidelity: The Game Changer in Surgical Simulators for the Next Decade? Front Oncol 2021; 11:713343. [PMID: 34458151 PMCID: PMC8386114 DOI: 10.3389/fonc.2021.713343] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2021] [Accepted: 07/22/2021] [Indexed: 11/13/2022] Open
Affiliation(s)
- Valentin Favier
- Department of Otolaryngology-Head and Neck Surgery, Gui de Chauliac Hospital, University Hospital of Montpellier, Montpellier, France.,Laboratory of Anatomy of Montpellier, Faculty of Medicine, Univ. Montpellier, Montpellier, France.,Research-team ICAR, Laboratory of Computer Science, Robotics and Microelectronics of Montpellier (LIRMM), Univ. Montpellier, French National Centre for Scientific Research (CNRS), Montpellier, France
| | - Gérard Subsol
- Research-team ICAR, Laboratory of Computer Science, Robotics and Microelectronics of Montpellier (LIRMM), Univ. Montpellier, French National Centre for Scientific Research (CNRS), Montpellier, France
| | - Martha Duraes
- Laboratory of Anatomy of Montpellier, Faculty of Medicine, Univ. Montpellier, Montpellier, France
| | - Guillaume Captier
- Laboratory of Anatomy of Montpellier, Faculty of Medicine, Univ. Montpellier, Montpellier, France.,Research-team ICAR, Laboratory of Computer Science, Robotics and Microelectronics of Montpellier (LIRMM), Univ. Montpellier, French National Centre for Scientific Research (CNRS), Montpellier, France
| | - Patrice Gallet
- Department of Otolaryngology-Head and Neck Surgery, Brabois Hospital, University Regional Hospital of Nancy, Lorraine University, Vandoeuvre-lès-Nancy, France.,Virtual Hospital of Lorraine, University of Lorraine, Vandoeuvre-lès-Nancy, France.,NGERE, INSERM U1256 lab, University of Lorraine, Vandoeuvre-lès-Nancy, France
| |
Collapse
|
15
|
Visual and haptic perceptibility of 3D printed skeletal models in orthognathic surgery. J Dent 2021; 109:103660. [PMID: 33848559 DOI: 10.1016/j.jdent.2021.103660] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2021] [Revised: 04/05/2021] [Accepted: 04/08/2021] [Indexed: 11/21/2022] Open
Abstract
OBJECTIVE To assess the anatomical and tactile quality of 3D printed models derived from medical printers for application in orthognathic surgery. METHODS A CBCT-scan of an 18 years old female patient was acquired with NewTom VGi evo (NewTom, Verona, Italy). Thereafter, mandibular bone was segmented and isolated from the scan using Mimics inPrint 2.0 software (Materialise NV, Leuven, Belgium). Six printers with different technologies were utilized for printing skeletal models, which included stereolithography (ProX800, 3D Systems, Rock Hill, SC, USA), digital light processing (Perfactory 4 mini XL, Envisiontec, Dearborn, MI, USA), fused deposition modeling (uPrint SE, Stratasys, Eden Prairie, MI, US), colorjet (ProJet CJP 660Pro, 3D Systems, Rock Hill, SC, USA), multijet (Objet Connex 350, Stratasys, Eden Prairie, MN, USA) and selective laser sintering (EOSINT P700, EOS GmbH, Munich, Germany). A questionnaire was designed, where 22 maxillofacial residents scored whether the printed models were able to mimic bone color, texture and anatomy. Five maxillofacial surgeons performed bone cutting with screw insertion/removal to assess the tactile perceptibility. RESULTS In relation to texture and cortical and medullary anatomy replication, Perfactory 4 mini XL printer showed the highest mean score, whereas, Objet Connex 350 scored highest for color replication. The haptic feedback for cutting and screw insertion/removal varied for each printer, however, overall it was found to be highest for ProX800, whereas, EOSINT P700 was found to be least favorable. CONCLUSIONS The digital light processing based Perfactory 4 mini XL printer offered the most acceptable anatomical model, whereas, deficiencies existed for the replication of haptic feedback to that of real bone with each printer. CLINICAL SIGNIFICANCE The study outcomes provide pearls and pitfalls of 3D printed models utilizing various printers and technologies. There is a need for research on multi-material printing as such to improve the haptic feedback of skeletal models and render the models more human bone-like to improve surgical planning and clinical training.
Collapse
|
16
|
Meglioli M, Naveau A, Macaluso GM, Catros S. 3D printed bone models in oral and cranio-maxillofacial surgery: a systematic review. 3D Print Med 2020; 6:30. [PMID: 33079298 PMCID: PMC7574578 DOI: 10.1186/s41205-020-00082-5] [Citation(s) in RCA: 47] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Accepted: 09/18/2020] [Indexed: 11/10/2022] Open
Abstract
AIM This systematic review aimed to evaluate the use of three-dimensional (3D) printed bone models for training, simulating and/or planning interventions in oral and cranio-maxillofacial surgery. MATERIALS AND METHODS A systematic search was conducted using PubMed® and SCOPUS® databases, up to March 10, 2019, by following the Preferred Reporting Items for Systematic reviews and Meta-Analysis (PRISMA) protocol. Study selection, quality assessment (modified Critical Appraisal Skills Program tool) and data extraction were performed by two independent reviewers. All original full papers written in English/French/Italian and dealing with the fabrication of 3D printed models of head bone structures, designed from 3D radiological data were included. Multiple parameters and data were investigated, such as author's purpose, data acquisition systems, printing technologies and materials, accuracy, haptic feedback, variations in treatment time, differences in clinical outcomes, costs, production time and cost-effectiveness. RESULTS Among the 1157 retrieved abstracts, only 69 met the inclusion criteria. 3D printed bone models were mainly used as training or simulation models for tumor removal, or bone reconstruction. Material jetting printers showed best performance but the highest cost. Stereolithographic, laser sintering and binder jetting printers allowed to create accurate models with adequate haptic feedback. The cheap fused deposition modeling printers exhibited satisfactory results for creating training models. CONCLUSION Patient-specific 3D printed models are known to be useful surgical and educational tools. Faced with the large diversity of software, printing technologies and materials, the clinical team should invest in a 3D printer specifically adapted to the final application.
Collapse
Affiliation(s)
- Matteo Meglioli
- University Center of Dentistry, Department of Medicine and Surgery, University of Parma, Via Gramsci 14, 43126, Parma, Italy
| | - Adrien Naveau
- Department of Prosthodontics, Dental Science Faculty, University of Bordeaux, 46 rue Léo-Saignat, 33076, Bordeaux, France.,Dental and Periodontal Rehabilitation Unit, Saint Andre Hospital, Bordeaux University Hospital, 46 rue Léo-Saignat, 33076, Bordeaux, France.,Biotis Laboratory, Inserm U1026, University of Bordeaux, 46 rue Léo-Saignat, 33076, Bordeaux, France
| | - Guido Maria Macaluso
- University Center of Dentistry, Department of Medicine and Surgery, University of Parma, Via Gramsci 14, 43126, Parma, Italy.,IMEM-CNR, Parco Area delle Scienze 37/A, 43124, Parma, Italy
| | - Sylvain Catros
- Biotis Laboratory, Inserm U1026, University of Bordeaux, 46 rue Léo-Saignat, 33076, Bordeaux, France. .,Department of Oral Surgery, UFR d'Odontologie, University of Bordeaux, 46 rue Léo-Saignat, 33076, Bordeaux, France. .,Service de Chirurgie Orale, CHU de Bordeaux, 46 rue Léo-Saignat, 33076, Bordeaux, France.
| |
Collapse
|
17
|
Favier V, Gallet P, Ferry O, Jehl JP. Spherical depth-sensing nanoindentation of human anterior skull base bones: Establishment of a test protocol. J Mech Behav Biomed Mater 2020; 110:103954. [PMID: 32957246 DOI: 10.1016/j.jmbbm.2020.103954] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2020] [Revised: 06/01/2020] [Accepted: 06/23/2020] [Indexed: 01/19/2023]
Abstract
The mechanical properties of anterior skull base (ASB) bones are not well understood due to their complex geometry and deep location. However, it is of particular interest for skull base surgeons to appraise the force range they can apply during procedures and know what kind of haptic feedback a simulation device should produce in order to be realistic for trainees. The aim of this study was to establish a measurement protocol to set the level of hydration state, temperature and curve analysis method for spherical depth sensing nanoindentation of ASB bones. A definitive screening design method was used to test the different possible combinations of these factors. Two samples of ASB bones from the heads of two human body donors (two specimens) were selected according to their microstructure as assessed by micro-CT (microtomography): low-porosity (16.87%, sphenoid bone) and high-porosity (79.85%, ethmoid bone). Depth measurement series of 36 nanoindentations (n = 288) were performed on specimen 1 according to the L8 Taguchi orthogonal array to study the effect of temperature (two levels: 20 or 37 °C), hydration state (dry or immerged in physiological saline sodium chloride), and loading curve analysis according to the Hertzian contact theory (fitting at the start or at the end). The mean values of reduced Young's (E*) modulus varied significantly depending on the hydration status and bone microstructure. In order to obtain the physiological properties of ASB bones, we thus propose performing immersion tests. To simplify the experimentation protocol, future experiments must include a room temperature level and a fit of the curve at the end of the load. A validation series was performed on the second specimen to assess the set of parameters. The E* in dry bone gave mean values of 994.68 MPa, versus 409.79 MPa in immerged bones (p < 0.00001). This is the first time a study has been carried out on ASB bones, defining the experimental parameters related to physiological conditions.
Collapse
Affiliation(s)
- Valentin Favier
- Aide à La Décision pour une Médecine Personnalisée, EA2415, Département MIPS, Université de Montpellier, Montpellier, France; Département D'ORL et Chirurgie Cervico-faciale, Centre Hospitalier Universitaire de Montpellier, Montpellier, France.
| | - Patrice Gallet
- Département D'ORL et Chirurgie Cervico-faciale, Hôpital Brabois, CHRU Nancy, Université de Lorraine, Vandoeuvre-lès-Nancy, France
| | - Olivier Ferry
- Institut Jean Lamour, Centre de Compétences Xj, CNRS UMR 7198, Université de Lorraine, Nancy, France
| | - Jean-Philippe Jehl
- Institut Jean Lamour, CNRS UMR 7198, Université de Lorraine, Nancy, France
| |
Collapse
|
18
|
Favier V, Najaf Y, Damecourt A, Subsol G, Captier G, Boetto J, Crampette L. Three-dimensional printing to compare endoscopic endonasal surgical approaches: A technical note. Clin Otolaryngol 2020; 46:106-109. [PMID: 32865888 DOI: 10.1111/coa.13641] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Revised: 06/24/2020] [Accepted: 08/23/2020] [Indexed: 11/27/2022]
Affiliation(s)
- Valentin Favier
- Department of Otolaryngology-Head and Neck Surgery and Maxillofacial Surgery, Gui de Chauliac Hospital, University Hospital of Montpellier, Montpellier, France.,Aide à la Décision Médicale Personnalisée, EA 2415, Montpellier University, Montpellier, France
| | - Yaser Najaf
- Department of Otolaryngology-Head and Neck Surgery and Maxillofacial Surgery, Gui de Chauliac Hospital, University Hospital of Montpellier, Montpellier, France
| | - Arnaud Damecourt
- Department of Otolaryngology-Head and Neck Surgery and Maxillofacial Surgery, Gui de Chauliac Hospital, University Hospital of Montpellier, Montpellier, France
| | - Gérard Subsol
- ICAR Team, Montpellier Laboratory of Informatics, Robotics and Microelectronics (LIRMM), French National Centre for Scientific Research (CNRS), Montpellier University, Montpellier, France
| | - Guillaume Captier
- Aide à la Décision Médicale Personnalisée, EA 2415, Montpellier University, Montpellier, France
| | - Julien Boetto
- Department of Neurosurgery, Gui de Chauliac Hospital, University Hospital of Montpellier, Montpellier, France
| | - Louis Crampette
- Department of Otolaryngology-Head and Neck Surgery and Maxillofacial Surgery, Gui de Chauliac Hospital, University Hospital of Montpellier, Montpellier, France
| |
Collapse
|
19
|
Maloca PM, Faludi B, Zelechowski M, Jud C, Vollmar T, Hug S, Müller PL, de Carvalho ER, Zarranz-Ventura J, Reich M, Lange C, Egan C, Tufail A, Hasler PW, Scholl HPN, Cattin PC. Validation of virtual reality orbitometry bridges digital and physical worlds. Sci Rep 2020; 10:11815. [PMID: 32678297 PMCID: PMC7366721 DOI: 10.1038/s41598-020-68867-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2020] [Accepted: 06/22/2020] [Indexed: 11/09/2022] Open
Abstract
Clinical science and medical imaging technology are traditionally displayed in two dimensions (2D) on a computer monitor. In contrast, three-dimensional (3D) virtual reality (VR) expands the realm of 2D image visualization, enabling an immersive VR experience with unhindered spatial interaction by the user. Thus far, analysis of data extracted from VR applications was mainly qualitative. In this study, we enhance VR and provide evidence for quantitative VR research by validating digital VR display of computed tomography (CT) data of the orbit. Volumetric CT data were transferred and rendered into a VR environment. Subsequently, seven graders performed repeated and blinded diameter measurements. The intergrader variability of the measurements in VR was much lower compared to measurements in the physical world and measurements were reasonably consistent with their corresponding elements in the real context. The overall VR measurements were 5.49% higher. As such, this study attests the ability of VR to provide similar quantitative data alongside the added benefit of VR interfaces. VR entails a lot of potential for the future research in ophthalmology and beyond in any scientific field that uses three-dimensional data.
Collapse
Affiliation(s)
- Peter M Maloca
- Institute of Molecular and Clinical Ophthalmology Basel (IOB), 4031, Basel, Switzerland. .,OCTlab, Department of Ophthalmology, University Hospital Basel, 4031, Basel, Switzerland. .,Department of Ophthalmology, University of Basel, 4031, Basel, Switzerland. .,Moorfields Eye Hospital NHS Foundation Trust, London, EC1V 2PD, UK.
| | - Balázs Faludi
- Center for Medical Image Analysis & Navigation, University of Basel, 4031, Basel, Switzerland
| | - Marek Zelechowski
- Center for Medical Image Analysis & Navigation, University of Basel, 4031, Basel, Switzerland
| | - Christoph Jud
- Center for Medical Image Analysis & Navigation, University of Basel, 4031, Basel, Switzerland
| | - Theo Vollmar
- MRZ Medical Radiology Center, 6004, Lucerne, Switzerland
| | - Sibylle Hug
- MRZ Medical Radiology Center, 6004, Lucerne, Switzerland
| | - Philipp L Müller
- Moorfields Eye Hospital NHS Foundation Trust, London, EC1V 2PD, UK
| | | | | | - Michael Reich
- Faculty of Medicine, Eye Center, Albert-Ludwigs University Freiburg, 79085, Freiburg, Germany
| | - Clemens Lange
- Faculty of Medicine, Eye Center, Albert-Ludwigs University Freiburg, 79085, Freiburg, Germany
| | - Catherine Egan
- Moorfields Eye Hospital NHS Foundation Trust, London, EC1V 2PD, UK
| | - Adnan Tufail
- Moorfields Eye Hospital NHS Foundation Trust, London, EC1V 2PD, UK
| | - Pascal W Hasler
- OCTlab, Department of Ophthalmology, University Hospital Basel, 4031, Basel, Switzerland.,Department of Ophthalmology, University of Basel, 4031, Basel, Switzerland
| | - Hendrik P N Scholl
- Institute of Molecular and Clinical Ophthalmology Basel (IOB), 4031, Basel, Switzerland.,Department of Ophthalmology, University of Basel, 4031, Basel, Switzerland.,Wilmer Eye Institute, Johns Hopkins University, Baltimore, 21287, USA
| | - Philippe C Cattin
- Center for Medical Image Analysis & Navigation, University of Basel, 4031, Basel, Switzerland
| |
Collapse
|
20
|
Hsieh TY, Cervenka B, Steele TO. Validation of Haptic Properties of Materials for Endoscopic Sinus and Skull Base Surgery Simulation-Reply. JAMA Otolaryngol Head Neck Surg 2019; 144:1185-1186. [PMID: 30193287 DOI: 10.1001/jamaoto.2018.1811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Affiliation(s)
- Tsung-Yen Hsieh
- Department of Otolaryngology-Head and Neck Surgery, University of California, Davis, Medical Center, Sacramento
| | - Brian Cervenka
- Department of Otolaryngology-Head and Neck Surgery, University of California, Davis, Medical Center, Sacramento
| | - Toby O Steele
- Department of Otolaryngology-Head and Neck Surgery, University of California, Davis, Medical Center, Sacramento.,Veterans Affairs Northern California Healthcare System, Sacramento, California
| |
Collapse
|
21
|
Favier V, Najaf Y, Captier G. Validation of Haptic Properties of Materials for Endoscopic Sinus and Skull Base Surgery Simulation. JAMA Otolaryngol Head Neck Surg 2019; 144:1184-1185. [PMID: 30193338 DOI: 10.1001/jamaoto.2018.1810] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Affiliation(s)
- Valentin Favier
- ENT Department, University Hospital of Montpellier, Gui de Chauliac Hospital, Montpellier, France
| | - Yaser Najaf
- ENT Department, University Hospital of Montpellier, Gui de Chauliac Hospital, Montpellier, France
| | - Guillaume Captier
- Anatomy Laboratory, School of Medicine, Montpellier University, Montpellier, France
| |
Collapse
|
22
|
Ruiters S, Mombaerts I. Applications of three-dimensional printing in orbital diseases and disorders. Curr Opin Ophthalmol 2019; 30:372-379. [PMID: 31261186 DOI: 10.1097/icu.0000000000000586] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
PURPOSE OF REVIEW To comprehensively review the applications of advanced three-dimensional printing technology in the management of orbital abnormalities. RECENT FINDINGS Three-dimensional printing has added value in the preoperative planning and manufacturing of patient-specific implants and surgical guides in the reconstruction of orbital trauma, congenital defects and tumor resection. In view of the costs and time, it is reserved as strategy for large and complex craniofacial cases, in particular those including the bony contour. There is anecdotal evidence of a benefit of three-dimensional printing in the manufacturing of prostheses for the exenterated and anophthalmic socket, and in the fabrication of patient-specific boluses, applicators and shielding devices for orbital radiation therapy. In addition, three-dimensional printed healthy and diseased orbits as phantom tangible models may augment the teaching and learning process of orbital surgery. SUMMARY Three-dimensional printing allows precision treatment tailored to the unique orbital anatomy of the patient. Advancement in technology and further research are required to support its wider use in orbital clinical practice.
Collapse
Affiliation(s)
- Sébastien Ruiters
- Department of Ophthalmology, University Hospitals Leuven, Leuven, Belgium
| | | |
Collapse
|
23
|
Various 3D printed materials mimic bone ultrasonographically: 3D printed models of the equine cervical articular process joints as a simulator for ultrasound guided intra-articular injections. PLoS One 2019; 14:e0220332. [PMID: 31386687 PMCID: PMC6684155 DOI: 10.1371/journal.pone.0220332] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Accepted: 07/12/2019] [Indexed: 11/22/2022] Open
Abstract
Introduction In the equine racehorse industry, reduced athletic performance due to joint injury and lameness has been extensively reviewed. Intra-articular injections of glucocorticoids are routinely used to relieve pain and inflammation associated with osteoarthritis. Intra-articular injections of pharmaceutical agents require practice for precise needle placement and to minimize complications. Training on simulators or models is a viable alternative for developing these technical skills. The purpose of this study was to compare the qualitative ultrasonographic characteristics of three-dimensional (3D) printed models of equine cervical articular process joints to that of a dissected equine cervical spine (gold standard). Methods A randomized complete block design study was conducted in which a total of thirteen cervical articular process joint models were printed using several materials, printers, and printing technologies. Ultrasound video clips with the models immersed in water were recorded. Two board certified veterinary radiologists and three veterinary radiology residents reviewed the videos and responded to a survey assessing and comparing the ultrasonographic characteristics of the 3D printed models to those of the gold standard. Results Six 3D printed models had ultrasonographic characteristics similar to the gold standard. These six models were (material, printer, printing technology): nylon PA 12, EOS Formiga P100, selective laser sintering (P = 0.99); Onyx nylon with chopped carbon fiber, Markforged Onyx Two, fused deposition modeling (P = 0.48); polycarbonate, Ultimaker 3, fused deposition modeling (P = 0.28); gypsum, ProJet CJP 660 Pro, ColorJet Printing (P = 0.28); polylactic acid, Prusa I3, fused deposition modeling (P = 0.23); and high temperature V1 resin, Form 2, stereolithography (P = 0.22). Conclusion When assessed in water, it is possible to replicate the qualitative ultrasonographic characteristics of bone using three dimensional printed models made by combining different materials, printing technologies, and printers. However, not all models share similar qualitative ultrasonographic characteristics with bone. We suggest that the aforementioned six models be used as proxy for simulating bones or joints for use with ultrasound. In order to replicate the resistance and acoustic window provided by soft tissues, further work testing the ability of these models to withstand embedding in material such as ballistic gelatin is required.
Collapse
|
24
|
Development of Mesh-Defect Removal Algorithm to Enhance the Fitting of 3D-Printed Parts for Comminuted Bone Fractures. J Med Biol Eng 2019. [DOI: 10.1007/s40846-019-00477-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
25
|
Favier V, Gallet P, Subsol G, Captier G. Understanding the Biomechanical Properties of Skull Base Tissues Is Essential for the Future of Virtual Reality Endoscopic Sinus and Skull Base Surgery Simulators. Clin Exp Otorhinolaryngol 2019; 12:231-232. [PMID: 30700086 PMCID: PMC6453791 DOI: 10.21053/ceo.2018.01627] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2018] [Accepted: 12/12/2018] [Indexed: 11/22/2022] Open
Affiliation(s)
- Valentin Favier
- Department of Otolaryngology-Head and Neck Surgery, Gui de Chauliac Hospital, University Hospital of Montpellier, Montpellier, France.,Aide à la Décision Médicale Personnalisée, Montpellier University, Montpellier, France
| | - Patrice Gallet
- Department of Otolaryngology-Head and Neck Surgery, Brabois Hospital, University Regional Hospital of Nancy, Lorraine University, Vandœuvre-lès-Nancy, France
| | - Gérard Subsol
- Montpellier Laboratory of Informatics, Robotics and Microelectonics (LIRMM), ICAR Team, French National Centre for Scientific Research (CNRS), Montpellier University, Montpellier, France
| | - Guillaume Captier
- Aide à la Décision Médicale Personnalisée, Montpellier University, Montpellier, France
| |
Collapse
|