1
|
Fauziah N, Rinawan FR, Nugraha NF, Faridah L, Jati KM, Dakosta A, Santika MK, Zakiyyudin MY, Muhsin A, Rizkillah KF, Nisa MN, Ristandi RB. Malaria elimination in West Java, Indonesia: A descriptive-and-qualitative study. J Vector Borne Dis 2024; 61:183-194. [PMID: 38922652 DOI: 10.4103/jvbd.jvbd_113_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Accepted: 09/05/2023] [Indexed: 06/27/2024] Open
Abstract
BACKGROUND OBJECTIVES Following World Health Organization (WHO) plans for thirty-five malaria-endemic countries, Indonesia will eliminate malaria by 2030. As one of the Indonesian provinces, West Java targeted subnational malaria elimination in 2022. This article aims to describe malaria surveillance data and elimination programs, including weaknesses in sustaining the program. METHODS This study used secondary data from malaria surveillance information system regencies/cities' case reports for 2019-2022 and achievement data of sub-national malaria elimination certification from each regency/city from 2014-2022. The data was confirmed from the evaluation study document, analysis of reported cases, and interviews. RESULTS Most cases were confirmed by microscopic examination (84.1% in 2021 and 94.4% in 2022) and rapid diagnostic tests (57% in 2019 and 58.1% in 2020). Malaria is more prevalent among men (93% in 2019, 95% in 2020, 96% in 2021, and 95.9% in 2022) and productive ages of 15-64 years (98.8% in 2019, 100% in 2020, 99.2% in 2021, and 98.8% in 2022), frequently occurs in the military (56.3% in 2019, 75.7% in 2020, 45.2% in 2021) and police (40.5% in 2022), often uses passive case detection for identifying cases (97.9% in 2019 and 2020, 95.2% in 2021, and 97.6% in 2022), and the majority undergo inpatient treatment (86.4% in 2019, 81.7% in 2021, and 82.6% in 2022). Most positive cases originated from imported cases, and last indigenous cases were still found in 2019. Plasmodium vivax dominated malaria cases and and relapses were high (55.0% in 2020, and 47.3% in 2022). INTERPRETATION CONCLUSION All regencies/cities have obtained sub-national malaria elimination certification in 2022. West Java has the potential to be verified for Java-Bali sub-national malaria elimination targeted in 2023, albeit cases of imported malaria still occur. It is imperative to address the issue of imported cases transitioning into locally transmitted cases (introduced) by effective coordination across all regencies/cities and inter-provincial efforts.
Collapse
Affiliation(s)
- Nisa Fauziah
- Division of Parasitology, Department of Biomedical Sciences, Faculty of Medicine, Universitas Padjadjaran, West Java, Indonesia
- Laboratory of Parasitology, Faculty of Medicine, Universitas Padjadjaran, West Java, Indonesia
- Research Center for Care and Control of Infectious Disease, Universitas Padjadjaran, West Java, Indonesia
| | - Fedri Ruluwedrata Rinawan
- Department of Public Health, Faculty of Medicine, Universitas Padjadjaran, West Java, Indonesia
- Center for Health System Study and Health Workforce Education Innovation, Faculty of Medicine, Universitas Padjadjaran, West Java, Indonesia
- Indonesian Society for Remote Sensing Branch West Java, Indoenesia
| | - Naufal Fakhri Nugraha
- Research Center for Care and Control of Infectious Disease, Universitas Padjadjaran, West Java, Indonesia
| | - Lia Faridah
- Division of Parasitology, Department of Biomedical Sciences, Faculty of Medicine, Universitas Padjadjaran, West Java, Indonesia
- Laboratory of Parasitology, Faculty of Medicine, Universitas Padjadjaran, West Java, Indonesia
- Research Center for Care and Control of Infectious Disease, Universitas Padjadjaran, West Java, Indonesia
| | - Karomahul Malaya Jati
- Undergraduate Medical Study Program, Faculty of Medicine, Universitas Padjadjaran, West Java, Indonesia
| | - Angelina Dakosta
- Undergraduate Medical Study Program, Faculty of Medicine, Universitas Padjadjaran, West Java, Indonesia
| | - Mahatyanta Kalya Santika
- Undergraduate Medical Study Program, Faculty of Medicine, Universitas Padjadjaran, West Java, Indonesia
| | - Muhammad Yusuf Zakiyyudin
- Undergraduate Medical Study Program, Faculty of Medicine, Universitas Padjadjaran, West Java, Indonesia
| | - Ahmad Muhsin
- Undergraduate Medical Study Program, Faculty of Medicine, Universitas Padjadjaran, West Java, Indonesia
| | | | - Miftahul Nurun Nisa
- Health Polytechnic of Health Ministry Yogyakarta, Yogyakarta, Indonesia
- World Health Organization (WHO) Country Office of Indonesia, Jakarta, Indonesia
| | | |
Collapse
|
2
|
Suwannin P, Jangpatarapongsa K, Polpanich D, Alhibshi A, Errachid A, Elaissari A. Enhancing leptospirosis control with nanosensing technology: A critical analysis. Comp Immunol Microbiol Infect Dis 2024; 104:102092. [PMID: 37992537 DOI: 10.1016/j.cimid.2023.102092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 11/07/2023] [Accepted: 11/09/2023] [Indexed: 11/24/2023]
Abstract
Leptospirosis is a serious health problem in tropical areas; thus, animals shed leptospires in the environment. Humans are accidental hosts infected through exposure to contaminating bacteria in the environment. One health strategy can be applied to protect and eliminate leptospirosis because this cooperates and coordinates activities between doctors, veterinarians, and ecologists. However, conventional methods still have limitations. Therefore, the main challenges of leptospirosis control are the high sensing of detection methods to screen and control the pathogens. Interestingly, nano sensing combined with a leptospirosis detection approach can increase the sensitivity and eliminate some limitations. This article reviews nanomaterial development for an advanced leptospirosis detection method, e.g., latex beads-based agglutination test, magnetic nanoparticles enrichment, and gold-nanoparticles-based immunochromatographic assay. Thus, nanomaterials can be functionalized with biomolecules or sensing molecules utilized in various mechanisms such as biosensors. Over the last decade, many biosensors have been developed for Leptospira spp. pathogen and others. The evolution of biosensors for leptospirosis detection was designed for high efficiency and might be an alternative tool. In addition, the high-sensing fabrications are useful for leptospires screening in very low levels, for example, soil or water from the environment.
Collapse
Affiliation(s)
- Patcharapan Suwannin
- Center for Research Innovation and Biomedical Informatics, Faculty of Medical Technology, Mahidol University, Bangkok 10700, Thailand; Univ Lyon, University Claude Bernard Lyon-1, CNRS, ISA-UMR 5280, Villeurbanne 69622, France
| | - Kulachart Jangpatarapongsa
- Center for Research Innovation and Biomedical Informatics, Faculty of Medical Technology, Mahidol University, Bangkok 10700, Thailand
| | - Duangporn Polpanich
- National Nanotechnology Center (NANOTEC), National Science and Technology Development Agency (NSTDA), Pathum Thani 12120, Thailand
| | - Amani Alhibshi
- Department of Neuroscience Research, Institute of Research and Medical Consultations, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia
| | - Abdelhamid Errachid
- Univ Lyon, University Claude Bernard Lyon-1, CNRS, ISA-UMR 5280, Villeurbanne 69622, France
| | - Abdelhamid Elaissari
- Univ Lyon, University Claude Bernard Lyon-1, CNRS, ISA-UMR 5280, Villeurbanne 69622, France.
| |
Collapse
|
3
|
Opoku Afriyie S, Addison TK, Gebre Y, Mutala AH, Antwi KB, Abbas DA, Addo KA, Tweneboah A, Ayisi-Boateng NK, Koepfli C, Badu K. Accuracy of diagnosis among clinical malaria patients: comparing microscopy, RDT and a highly sensitive quantitative PCR looking at the implications for submicroscopic infections. Malar J 2023; 22:76. [PMID: 36870966 PMCID: PMC9985253 DOI: 10.1186/s12936-023-04506-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Accepted: 02/18/2023] [Indexed: 03/06/2023] Open
Abstract
BACKGROUND The World Health Organization recommends parasitological confirmation of all suspected malaria cases by microscopy or rapid diagnostic tests (RDTs) before treatment. These conventional tools are widely used for point-of-care diagnosis in spite of their poor sensitivity at low parasite density. Previous studies in Ghana have compared microscopy and RDT using standard 18S rRNA PCR as reference with varying outcomes. However, how these conventional tools compare with ultrasensitive varATS qPCR has not been studied. This study, therefore, sought to investigate the clinical performance of microscopy and RDT assuming highly sensitive varATS qPCR as gold standard. METHODS 1040 suspected malaria patients were recruited from two primary health care centers in the Ashanti Region of Ghana and tested for malaria by microscopy, RDT, and varATS qPCR. The sensitivity, specificity, and predictive values were assessed using varATS qPCR as gold standard. RESULTS Parasite prevalence was 17.5%, 24.5%, and 42.1% by microscopy, RDT, and varATS qPCR respectively. Using varATS qPCR as the standard, RDT was more sensitive (55.7% vs 39.3%), equally specific (98.2% vs 98.3%), and reported higher positive (95.7% vs 94.5%) and negative predictive values (75.3% vs 69.0%) than microscopy. Consequently, RDT recorded better diagnostic agreement (kappa = 0.571) with varATS qPCR than microscopy (kappa = 0.409) for clinical detection of malaria. CONCLUSIONS RDT outperformed microscopy for the diagnosis of Plasmodium falciparum malaria in the study. However, both tests missed over 40% of infections that were detected by varATS qPCR. Novel tools are needed to ensure prompt diagnosis of all clinical malaria cases.
Collapse
Affiliation(s)
- Stephen Opoku Afriyie
- Department of Theoretical and Applied Biology, Kwame Nkrumah University of Science and Technology (KNUST), Kumasi, Ghana
| | - Thomas Kwame Addison
- Department of Theoretical and Applied Biology, Kwame Nkrumah University of Science and Technology (KNUST), Kumasi, Ghana
| | - Yilekal Gebre
- Department of Biological Sciences, University of Notre Dame, South Bend, IN, USA
| | - Abdul-Hakim Mutala
- Department of Theoretical and Applied Biology, Kwame Nkrumah University of Science and Technology (KNUST), Kumasi, Ghana
| | - Kwasi Baako Antwi
- Department of Theoretical and Applied Biology, Kwame Nkrumah University of Science and Technology (KNUST), Kumasi, Ghana
| | - Dawood Ackom Abbas
- Department of Theoretical and Applied Biology, Kwame Nkrumah University of Science and Technology (KNUST), Kumasi, Ghana
| | - Kofi Agyapong Addo
- Department of Theoretical and Applied Biology, Kwame Nkrumah University of Science and Technology (KNUST), Kumasi, Ghana
| | - Austine Tweneboah
- Department of Theoretical and Applied Biology, Kwame Nkrumah University of Science and Technology (KNUST), Kumasi, Ghana
| | | | - Cristian Koepfli
- Department of Biological Sciences, University of Notre Dame, South Bend, IN, USA.
| | - Kingsley Badu
- Department of Theoretical and Applied Biology, Kwame Nkrumah University of Science and Technology (KNUST), Kumasi, Ghana.
| |
Collapse
|
4
|
Assessing the diagnostic performance of a novel RT-PCR fluorescence method for the detection of human plasmodium species. PLoS One 2022; 17:e0272094. [PMID: 35925877 PMCID: PMC9352105 DOI: 10.1371/journal.pone.0272094] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Accepted: 07/12/2022] [Indexed: 11/19/2022] Open
Abstract
Background Malaria elimination effort is hampered not only by the lack of effective medication but also due to the lack of sensitive diagnostic tools to detect infections with low levels of parasitemia. Therefore, more sensitive and specific high-throughput molecular diagnostic approaches are needed for accurate malaria diagnosis. Methods In the present study, the performance of a novel single-tube MC004 real-time polymerase chain reaction (PCR) assay (MRC-Holland, Amsterdam, the Netherlands) was assessed for the detection of infection and discrimination of Plasmodium species. Blood samples (n = 150) were collected from malaria suspected patients at Adama malaria diagnosis and treatment centre, Adama, central Ethiopia. The positive predictive value (PPV), negative predictive value (NPV), analytical sensitivity and specificity of the assay were assessed against the conventional microscopic method. Results Plasmodium species were detected in 59 (39.3%) of the samples by microscopy and in 62 (41.3%) by the novel MC004 RT-PCR. Plasmodium vivax, Plasmodium falciparum and mixed infections with Plasmodium falciparum & Plasmodium vivax accounted for 47.5%, 40.6% and 11.9% respectively as detected by microscopy. The MC004 RT-PCR assay identified 59.7% and 40.3% of the samples positive for Plasmodium vivax and Plasmodium falciparum respectively. The sensitivity, specificity, PPV, and NPV of the MC004 RT-PCR assay were 95.8%, 97.8%, 92%, and 98.9%, respectively. No mixed infections were detected using the MC004 assay. Conclusion The MC004 RT-PCR assay is a useful tool for the early detection of malaria and identification of Plasmodium species with a high degree of sensitivity and specificity. Due to its high sensitivity, and simplicity (being a single-tube assay), the MC004 is suitable for use in clinical settings and epidemiological studies.
Collapse
|
5
|
Lekpor CE, Botchway F, Kusi KA, Adjei AA, Wilson MD, Stiles JK, Wilson NO. Angiogenic and angiostatic factors present in the saliva of malaria patients. Malar J 2022; 21:220. [PMID: 35836234 PMCID: PMC9284857 DOI: 10.1186/s12936-022-04221-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 06/14/2022] [Indexed: 11/24/2022] Open
Abstract
Background Malaria related mortality is associated with significant deregulation of host inflammatory factors such as interferon-inducible protein 10, a member of the CXC or α-subfamily (CXCL10), and host angiogenic factors such as angiopoietin 1 (Ang-1) and angiopoietin 2 (Ang-2). However, detection of these factors in malaria patients requires the drawing of blood, which is invasive and increases the risk of accidental blood-borne infections. There has been an increased interest in the use of saliva as the body fluid of choice for the diagnosis of many infectious diseases including malaria. Here, saliva levels of CXCL10, Ang-1, and Ang-2 previously shown to be predictive of severe malaria in malaria patients in Ghana were assessed in malaria patients. Methods This study was conducted in the Shai-Osudoku District Hospital in Dodowa, Accra, Ghana and the study population comprised 119 malaria patients and 94 non-malaria subjects. The non-malaria subjects are healthy community participants with no malaria infection. Plasma and saliva levels of CXCL10, Ang-1 and Ang-2 of the study participants were measured using an enzyme-linked immunoassay. Complete blood counts of each participant were measured with a haematology autoanalyzer. Pearson correlation was used to evaluate the correlation between plasma and saliva levels of each biomarker in malaria patients. A p-value of < 0.05 was considered significant. Box plots of median biomarker concentrations were plotted. SPSS version 14.2 software was used for statistical analysis. Results The non-malaria subjects had a median age of 29 years compared to 23 years for malaria patients (p = 0.001). Among the malaria patients, there was a strong significant relationship between CXCL10 (R2 = 0.7, p < 0.0001) and Ang-1 (R2 = 0.7, p < 0.0001). Malaria patients had lower saliva levels of Ang-1 (p = 0.009) and higher saliva levels of CXCL10 (p = 0.004) and Ang-2 (p = 0.001) compared to non-malaria subjects. Conclusions This study provides the first evidence of elevated levels of CXCL10 and Ang-2 in the saliva of malaria patients. Detection of CXCL10, Ang-1 and Ang-2 in saliva may have a potential application for non-invasive malaria diagnosis.
Collapse
Affiliation(s)
- Cecilia Elorm Lekpor
- Department of Pathology, Korle-Bu Teaching Hospital, University of Ghana Medical School, Accra, Ghana.
| | - Felix Botchway
- Department of Chemical Pathology, University of Ghana Medical School, Korle-Bu Teaching Hospital, Accra, Ghana
| | - Kwadwo Asamoah Kusi
- Department of Immunology, Noguchi Memorial Institute for Medical Research, University of Ghana, Accra, Ghana.,Department of Parasitology, Noguchi Memorial Institute for Medical Research, University of Ghana, Accra, Ghana
| | - Andrew A Adjei
- Department of Pathology, Korle-Bu Teaching Hospital, University of Ghana Medical School, Accra, Ghana
| | - Michael D Wilson
- Department of Parasitology, Noguchi Memorial Institute for Medical Research, University of Ghana, Accra, Ghana
| | - Jonathan K Stiles
- Department of Microbiology, Biochemistry & Immunology, Morehouse School of Medicine, Atlanta, GA, USA
| | - Nana O Wilson
- Department of Microbiology, Biochemistry & Immunology, Morehouse School of Medicine, Atlanta, GA, USA.
| |
Collapse
|
6
|
Oyegoke OO, Maharaj L, Akoniyon OP, Kwoji I, Roux AT, Adewumi TS, Maharaj R, Oyebola BT, Adeleke MA, Okpeku M. Malaria diagnostic methods with the elimination goal in view. Parasitol Res 2022; 121:1867-1885. [PMID: 35460369 PMCID: PMC9033523 DOI: 10.1007/s00436-022-07512-9] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Accepted: 04/01/2022] [Indexed: 01/08/2023]
Abstract
Malaria control measures have been in use for years but have not completely curbed the spread of infection. Ultimately, global elimination is the goal. A major playmaker in the various approaches to reaching the goal is the issue of proper diagnosis. Various diagnostic techniques were adopted in different regions and geographical locations over the decades, and these have invariably produced diverse outcomes. In this review, we looked at the various approaches used in malaria diagnostics with a focus on methods favorably used during pre-elimination and elimination phases as well as in endemic regions. Microscopy, rapid diagnostic testing (RDT), loop-mediated isothermal amplification (LAMP), and polymerase chain reaction (PCR) are common methods applied depending on prevailing factors, each with its strengths and limitations. As the drive toward the elimination goal intensifies, the search for ideal, simple, fast, and reliable point-of-care diagnostic tools is needed more than ever before to be used in conjunction with a functional surveillance system supported by the ideal vaccine.
Collapse
Affiliation(s)
- Olukunle O Oyegoke
- Discipline of Genetics School of Life Sciences, University of KwaZulu-Natal, Westville, Durban, South Africa
| | - Leah Maharaj
- Discipline of Genetics School of Life Sciences, University of KwaZulu-Natal, Westville, Durban, South Africa
| | - Oluwasegun P Akoniyon
- Discipline of Genetics School of Life Sciences, University of KwaZulu-Natal, Westville, Durban, South Africa
| | - Illiya Kwoji
- Discipline of Genetics School of Life Sciences, University of KwaZulu-Natal, Westville, Durban, South Africa
| | - Alexandra T Roux
- Discipline of Genetics School of Life Sciences, University of KwaZulu-Natal, Westville, Durban, South Africa
| | - Taiye S Adewumi
- Discipline of Genetics School of Life Sciences, University of KwaZulu-Natal, Westville, Durban, South Africa
| | - Rajendra Maharaj
- Office of Malaria Research, Medical Research Council, Durban, South Africa
| | | | - Matthew A Adeleke
- Discipline of Genetics School of Life Sciences, University of KwaZulu-Natal, Westville, Durban, South Africa
| | - Moses Okpeku
- Discipline of Genetics School of Life Sciences, University of KwaZulu-Natal, Westville, Durban, South Africa.
| |
Collapse
|
7
|
Chaturvedi R, Deora N, Bhandari D, Parvez S, Sinha A, Sharma A. Trends of neglected Plasmodium species infection in humans over the past century in India. One Health 2021; 11:100190. [PMID: 33251321 PMCID: PMC7683271 DOI: 10.1016/j.onehlt.2020.100190] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2020] [Revised: 10/22/2020] [Accepted: 10/23/2020] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND Efforts for malaria elimination in India focus solely on the more prevalent human malaria parasites of Plasmodium falciparum (Pf) and Plasmodium vivax (Pv). The three non-Pf/Pv species - Plasmodium malariae (Pm), Plasmodium ovale (Po) and Plasmodium knowlesi (Pk) are seldom studied though they are often present as mixed infections with Pf/Pv and thus may be misdiagnosed. This study provides a comprehensive landscape of Pm, Po, and Pk infections from 1930 to 2020. METHODOLOGY We systematically searched for published literature on Pm, Po, and Pk in India from PubMed database and collated data from 35 studies. The data, starting from 1930, were mapped decade-wise across India. The prevalence of the three neglected Plasmodium species and their proportional contribution to reported Plasmodium mixed-infection were also calculated and analysed. PRINCIPAL FINDINGS Amongst the three non-Pf/Pv species, Pm infections have been reported in greater numbers across India and were mostly mono-infections till 1980. From 1983 onwards, reports of Pm mixed infections with Pf/Pv started to emerge. In contrast, reports on occurrence of Po are still rare barring few mixed infection studies. Further, Pk mono- and mixed cases were first reported in 2004 in India and Pk now has been found reported from four Indian states. CONCLUSION This is the first account of country-wide assimilation of reported malaria parasite species data that covers Pm, Po, and Pk infection profiles from 1930 to 2020. This study illustrates the need to survey all 5 human malaria parasite species in India and to target them collectively during the malaria elimination phase.
Collapse
Key Words
- ACT, Artemisinin-based combination therapy
- AL, Artemether-Lumefantrine
- AS, Artesunate
- CDC, Centres for Disease Control and Prevention
- DBS, Dried Blood Spots
- G6PD, Glucose-6-Phosphate Dehydrogenase.
- IV, intravenous
- LAMP, Loop-mediated isothermal amplification.
- Neglected Plasmodium species
- P. knowlesi
- P. malariae
- P. ovale
- PCR, Polymerase Chain Reaction
- POC, Point of Care,
- RDT, Rapid Diagnostic Tests
- SP, Sulfadoxine-Pyrimethamine
- malaria
Collapse
Affiliation(s)
- Rini Chaturvedi
- Molecular Medicine Group, International Centre for Genetic Engineering and Biotechnology, New Delhi, India
- Department of Toxicology, Jamia Hamdard, New Delhi, India
| | - Nimita Deora
- ICMR-National Institute of Malaria Research, New Delhi, India
| | - Deepam Bhandari
- Molecular Medicine Group, International Centre for Genetic Engineering and Biotechnology, New Delhi, India
| | - Suhel Parvez
- Department of Toxicology, Jamia Hamdard, New Delhi, India
| | - Abhinav Sinha
- ICMR-National Institute of Malaria Research, New Delhi, India
| | - Amit Sharma
- Molecular Medicine Group, International Centre for Genetic Engineering and Biotechnology, New Delhi, India
- ICMR-National Institute of Malaria Research, New Delhi, India
| |
Collapse
|
8
|
Malaria Rapid Diagnostic Tests: Literary Review and Recommendation for a Quality Assurance, Quality Control Algorithm. Diagnostics (Basel) 2021; 11:diagnostics11050768. [PMID: 33922917 PMCID: PMC8145891 DOI: 10.3390/diagnostics11050768] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 04/20/2021] [Accepted: 04/21/2021] [Indexed: 01/24/2023] Open
Abstract
Malaria rapid diagnostic tests (RDTs) have had an enormous global impact which contributed to the World Health Organization paradigm shift from empiric treatment to obtaining a parasitological diagnosis prior to treatment. Microscopy, the classic standard, requires significant expertise, equipment, electricity, and reagents. Alternatively, RDT’s lower complexity allows utilization in austere environments while achieving similar sensitivities and specificities. Worldwide, there are over 200 different RDT brands that utilize three antigens: Plasmodium histidine-rich protein 2 (PfHRP-2), Plasmodium lactate dehydrogenase (pLDH), and Plasmodium aldolase (pALDO). pfHRP-2 is produced exclusively by Plasmodium falciparum and is very Pf sensitive, but an alternative antigen or antigen combination is required for regions like Asia with significant Plasmodium vivax prevalence. RDT sensitivity also decreases with low parasitemia (<100 parasites/uL), genetic variability, and prozone effect. Thus, proper RDT selection and understanding of test limitations are essential. The Center for Disease Control recommends confirming RDT results by microscopy, but this is challenging, due to the utilization of clinical laboratory standards, like the College of American Pathologists (CAP) and the Clinical Lab Improvement Act (CLIA), and limited recourses. Our focus is to provide quality assurance and quality control strategies for resource-constrained environments and provide education on RDT limitations.
Collapse
|
9
|
Differential susceptibility of Onchocerca volvulus microfilaria to ivermectin in two areas of contrasting history of mass drug administration in Cameroon: relevance of microscopy and molecular techniques for the monitoring of skin microfilarial repopulation within six months of direct observed treatment. BMC Infect Dis 2020; 20:726. [PMID: 33008333 PMCID: PMC7530974 DOI: 10.1186/s12879-020-05444-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Accepted: 09/23/2020] [Indexed: 11/24/2022] Open
Abstract
Background Ivermectin is an excellent microfilaricide against Onchocerca volvulus. However, in some regions, long term use of ivermectin has resulted in sub-optimal responses to the treatment. More data to properly document the phenomenon in various contexts of ivermectin mass drug administration (IVM-MDA) is needed. Also, there is a need to accurately monitor a possible repopulation of skin by microfilariae following treatment. Skin snip microscopy is known to have a low sensitivity in individuals with light infections, which can be the case following treatment. This study was designed with two complementary objectives: (i) to assess the susceptibility of O. volvulus microfilariae to ivermectin in two areas undergoing IVM-MDA for different lengths of time, and (ii) to document the repopulation of skin by the O. volvulus microfilariae following treatment, using 3 independent diagnostic techniques. Method Identified microfilaridermic individuals were treated with ivermectin and re-examined after 1, 3, and 6 months using microscopy, actin real-time PCR (actin-qPCR) and O-150 LAMP assays. Susceptibility to ivermectin and trends in detecting reappearance of skin microfilariae were determined using three techniques. Microscopy was used as an imperfect gold standard to determine the performance of actin-qPCR and LAMP. Results In Bafia with over 20 years of IVM-MDA, 11/51 (21.6%) direct observe treated microfilaridemic participants were still positive for skin microfilariae after 1 month. In Melong, with 10 years of IVM-MDA, 2/29 (6.9%) treated participants were still positive. The microfilarial density reduction per skin biopsy within one month following treatment was significantly lower in participants from Bafia. In both study sites, the molecular techniques detected higher proportions of infected individuals than microscopy at all monitoring time points. LAMP demonstrated the highest levels of sensitivity and real-time PCR was found to have the highest specificity. Conclusion Patterns in skin mirofilariae clearance and repopulation were established. O. volvulus worms from Bafia with higher number of annual MDA displayed a lower clearance and higher repopulation rate after treatment with ivermectin. Molecular assays displayed higher sensitivity in monitoring O. volvulus microfilaridemia within six months following treatment.
Collapse
|
10
|
Gachugia J, Chebore W, Otieno K, Ngugi CW, Godana A, Kariuki S. Evaluation of the colorimetric malachite green loop-mediated isothermal amplification (MG-LAMP) assay for the detection of malaria species at two different health facilities in a malaria endemic area of western Kenya. Malar J 2020; 19:329. [PMID: 32907582 PMCID: PMC7487890 DOI: 10.1186/s12936-020-03397-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2020] [Accepted: 08/30/2020] [Indexed: 01/03/2023] Open
Abstract
Background Prompt diagnosis and effective malaria treatment is a key strategy in malaria control. However, the recommended diagnostic methods, microscopy and rapid diagnostic tests (RDTs), are not supported by robust quality assurance systems in endemic areas. This study compared the performance of routine RDTs and smear microscopy with a simple molecular-based colorimetric loop-mediated isothermal amplification (LAMP) at two different levels of the health care system in a malaria-endemic area of western Kenya. Methods Patients presenting with clinical symptoms of malaria at Rota Dispensary (level 2) and Siaya County Referral Hospital (level 4) were enrolled into the study after obtaining written informed consent. Capillary blood was collected to test for malaria by RDT and microscopy at the dispensary and county hospital, and for preparation of blood smears and dried blood spots (DBS) for expert microscopy and real-time polymerase chain reaction (RT-PCR). Results of the routine diagnostic tests were compared with those of malachite green loop-mediated isothermal amplification (MG-LAMP) performed at the two facilities. Results A total of 264 participants were enrolled into the study. At the dispensary level, the positivity rate by RDT, expert microscopy, MG-LAMP and RT-PCR was 37%, 30%, 44% and 42%, respectively, and 42%, 43%, 57% and 43% at the county hospital. Using RT-PCR as the reference test, the sensitivity of RDT and MG-LAMP was 78.1% (CI 67.5–86.4) and 82.9% (CI 73.0–90.3) at Rota dispensary. At Siaya hospital the sensitivity of routine microscopy and MG-LAMP was 83.3% (CI 65.3–94.4) and 93.3% (CI 77.9–99.2), respectively. Compared to MG-LAMP, there were 14 false positives and 29 false negatives by RDT at Rota dispensary and 3 false positives and 13 false negatives by routine microscopy at Siaya Hospital. Conclusion MG-LAMP is more sensitive than RDTs and microscopy in the detection of malaria parasites at public health facilities and might be a useful quality control tool in resource-limited settings.
Collapse
Affiliation(s)
- James Gachugia
- Department of Medical Microbiology, College of Health Sciences, Jomo Kenyatta University of Agriculture and Technology, P. O. Box 62000-00200, Nairobi, Kenya
| | - Winnie Chebore
- Kenya Medical Research Institute, Centre for Global Health Research, P. O. Box 1578-40100, Kisumu, Kenya
| | - Kephas Otieno
- Kenya Medical Research Institute, Centre for Global Health Research, P. O. Box 1578-40100, Kisumu, Kenya
| | - Caroline Wangari Ngugi
- Department of Medical Microbiology, College of Health Sciences, Jomo Kenyatta University of Agriculture and Technology, P. O. Box 62000-00200, Nairobi, Kenya
| | - Adano Godana
- National Malaria Control Programme, Ministry of Health, Kenyatta National Hospital, P. O. Box, Nairobi, 19982-00202, Kenya
| | - Simon Kariuki
- Kenya Medical Research Institute, Centre for Global Health Research, P. O. Box 1578-40100, Kisumu, Kenya.
| |
Collapse
|
11
|
Picot S, Cucherat M, Bienvenu AL. Systematic review and meta-analysis of diagnostic accuracy of loop-mediated isothermal amplification (LAMP) methods compared with microscopy, polymerase chain reaction and rapid diagnostic tests for malaria diagnosis. Int J Infect Dis 2020; 98:408-419. [PMID: 32659450 DOI: 10.1016/j.ijid.2020.07.009] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2020] [Revised: 07/01/2020] [Accepted: 07/05/2020] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND Diagnosis is a challenging issue for eliminating malaria. Loop-mediated isothermal amplification (LAMP) could be an alternative to conventional methods. This study aimed to evaluate the diagnostic accuracy of LAMP for malaria compared with microscopy, polymerase chain reaction (PCR) and rapid diagnostic tests (RDTs). METHODS AND DESIGN MEDLINE, Web of Science and Scopus were searched from inception to 1 July 2019. Prospective and retrospective, randomised and non-randomised, mono-center and multi-center studies, including symptomatic or asymptomatic patients, that reported one LAMP method and one comparator (microscopy, RDT or PCR) were included. PROSPERO registration number: CRD42017075186. RESULTS Sixty-six studies published between 2006 and 2019 were included, leading to the analysis of 30,641 LAMP tests. The pooled sensitivity of LAMP remained between 96% and 98%, whichever the comparator. The pooled specificity of LAMP was around 95%, but was a little higher if the best PCR studies were considered. The AUC was found to be >0.98, whichever the subgroup of studies was considered. Diagnostic odds ratio (DOR) was found to be around 1000 for all subgroups, except for Plasmodium vivax. CONCLUSION This meta-analysis confirmed that the LAMP method is robust for diagnosing malaria, both in symptomatic and asymptomatic people. Thus, the impact of LAMP for controlling malaria is expected to be important.
Collapse
Affiliation(s)
- Stephane Picot
- Malaria Research Unit, SMITh, ICBMS UMR 5246 CNRS-INSA-CPE-Université de Lyon, Campus Lyon-Tech La Doua, 69622 Villeurbanne Cedex, France; Institut de Parasitologie et Mycologie Médicale, Hôpital de La Croix-Rousse, Hospices Civils de Lyon, Lyon, France
| | - Michel Cucherat
- Service de Pharmacotoxicologie, Hospices Civils de Lyon, Laboratoire de Biométrie et Biologie Évolutive, CNRS, UMR5558, Université Lyon 1, Lyon, France
| | - Anne-Lise Bienvenu
- Malaria Research Unit, SMITh, ICBMS UMR 5246 CNRS-INSA-CPE-Université de Lyon, Campus Lyon-Tech La Doua, 69622 Villeurbanne Cedex, France; Service Pharmacie, Groupement Hospitalier Nord, Hospices Civils de Lyon, France; Service d'Hématologie, Groupement Hospitalier Nord, Hospices Civils de Lyon, France.
| |
Collapse
|
12
|
Loop Mediated Isothermal Amplification: A Promising Tool for Screening Genetic Mutations. Mol Diagn Ther 2020; 23:723-733. [PMID: 31396882 DOI: 10.1007/s40291-019-00422-0] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Mutation screening is elemental for clinical diagnosis and in determining therapeutic strategies. Nucleic acid-based techniques are considered to be the most accurate tools in genetic diagnosis. One such technique is loop-mediated isothermal amplification (LAMP) assay, which has seen tremendous applications in recent years. The advantages of the assay lie in its rapidity, efficiency, sensitivity, and cost. It works in isothermal conditions and amplifies the target gene using DNA polymerases that have strand displacement activity. To date, the assay has been widely used in different fields of research, including pathogen detection, crop development, and disease diagnosis. However, despite the potential, its application in mutation screening has been minimal. This review highlights the LAMP assay and its variants that have been developed for screening single-nucleotide polymorphisms and gene translocations in cancer.
Collapse
|