1
|
Fang Z, Bi S, Brown JD, Chen J, Pan T. Microfluidics in the eye: a review of glaucoma implants from an engineering perspective. LAB ON A CHIP 2023; 23:4736-4772. [PMID: 37847237 DOI: 10.1039/d3lc00407d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2023]
Abstract
Glaucoma is a progressive optic neuropathy in the eye, which is a leading cause of irreversible blindness worldwide and currently affects over 70 million individuals. Clinically, intraocular pressure (IOP) reduction is the only proven treatment to halt the progression of glaucoma. Microfluidic devices such as glaucoma drainage devices (GDDs) and minimally invasive glaucoma surgery (MIGS) devices are routinely used by ophthalmologists to manage elevated IOP, by creating an artificial pathway for the over-accumulated aqueous humor (AH) in a glaucomatous eye, when the natural pathways are severely blocked. Herein, a detailed modelling and analysis of both the natural microfluidic pathways of the AH in the eye and artificial microfluidic pathways formed additionally by the various glaucoma implants are conducted to provide an insight into the causes of the IOP abnormality and the improvement schemes of current implant designs. The mechanisms of representative glaucoma implants have been critically reviewed from the perspective of microfluidics, and we have categorized the current implants into four groups according to the targeted drainage sites of the AH, namely Schlemm's canal, suprachoroidal space, subconjunctival space, and ocular surface. In addition, we propose to divide the development and evolution of glaucoma implant designs into three technological waves, which include microtube (1st), microvalve (2nd) and microsystem (3rd). With the emerging trends of minimal invasiveness and artificial intelligence in the development of medical implants, we envision that a comprehensive glaucoma treatment microsystem is on the horizon, which is featured with active and wireless control of IOP, real-time continuous monitoring of IOP and aqueous rate, etc. The current review could potentially cast light on the unmatched needs, challenges, and future directions of the microfluidic structural and functional designs of glaucoma implants, which would enable an enhanced safety profile, reduced complications, increased efficacy of lowering IOP and reduced IOP fluctuations, closed-loop and on-demand control of IOP, etc.
Collapse
Affiliation(s)
- Zecong Fang
- Bionic Sensing and Intelligence Center (BSIC), Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China.
| | - Shuzhen Bi
- Center for Intelligent Medical Equipment and Devices (iMED), University of Science and Technology of China, Suzhou, Jiangsu, 215123, China
| | | | - Junyi Chen
- Department of Ophthalmology and Visual Science, Eye and ENT Hospital, Shanghai Medical College, Fudan University, Shanghai, 200031, China
- NHC Key Laboratory of Myopia, Chinese Academy of Medical Sciences, and Shanghai Key Laboratory of Visual Impairment and Restoration (Fudan University), Shanghai, 200031, China
| | - Tingrui Pan
- Bionic Sensing and Intelligence Center (BSIC), Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China.
- Center for Intelligent Medical Equipment and Devices (iMED), University of Science and Technology of China, Suzhou, Jiangsu, 215123, China
- Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, Anhui, 230026, China
| |
Collapse
|
2
|
Shah S, Patel V. Targeting posterior eye infections with colloidal carriers: The case of Ganciclovir. Int J Pharm 2023; 645:123427. [PMID: 37729977 DOI: 10.1016/j.ijpharm.2023.123427] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Revised: 09/09/2023] [Accepted: 09/17/2023] [Indexed: 09/22/2023]
Abstract
The ocular system, unlike any other human body organ, is a system in which foreign bodies appear quite defenceless in front of the eye. Several infections of the ocular system occur due to various opportunistic conditions. Cytomegalovirus (CMV) is one of the opportunivores that causes several posterior eye infections. Ganciclovir (GCV),9-(2-hydroxy-1-(hydroxymethyl) ethoxymethyl), is aguanine-antiviral agent primarily used to treat CMV diseases. However, the major challenge is of lower bioavailability. Hence, GCV must be dosed repeatedly to enhance drug absorption. but this causes side effects like neutropenia and bone marrow suppression. So, formulators have used alternative formulation strategies such as prodrug formulation and colloidal drug delivery systems. In the prodrug strategy, they attempted to bind various compounds into the parent drug to increase the permeability and bioavailability of GCV. In colloidal drug delivery systems, mucoadhesive microspheres, nanoparticles, Niosome and liposome were employed to extend the drug residence time at the application site. This paper discusses several colloidal carriers combined with GCV to treat opportunistic CMV infection in the posterior ocular system. It reviews the limitations of conventional ocular therapy and explores various novel formulation approaches to improve the ocular bioavailability of GCV in the posterior chamber of the eye.
Collapse
Affiliation(s)
- Srushti Shah
- Parul Institute of Pharmacy, ParulUniversity, Gujarat 391760, India.
| | - Vandana Patel
- Krishna School of Pharmacy and Research, KPGU, Gujarat 391240, India
| |
Collapse
|
3
|
Josyula A, Mozzer A, Szeto J, Ha Y, Richmond N, Chung SW, Rompicharla SVK, Narayan J, Ramesh S, Hanes J, Ensign L, Parikh K, Pitha I. Nanofiber-based glaucoma drainage implant improves surgical outcomes by modulating fibroblast behavior. Bioeng Transl Med 2023; 8:e10487. [PMID: 37206200 PMCID: PMC10189467 DOI: 10.1002/btm2.10487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 12/01/2022] [Accepted: 12/19/2022] [Indexed: 11/02/2023] Open
Abstract
Biomaterials are implanted in millions of individuals worldwide each year. Both naturally derived and synthetic biomaterials induce a foreign body reaction that often culminates in fibrotic encapsulation and reduced functional lifespan. In ophthalmology, glaucoma drainage implants (GDIs) are implanted in the eye to reduce intraocular pressure (IOP) in order to prevent glaucoma progression and vision loss. Despite recent efforts towards miniaturization and surface chemistry modification, clinically available GDIs are susceptible to high rates of fibrosis and surgical failure. Here, we describe the development of synthetic, nanofiber-based GDIs with partially degradable inner cores. We evaluated GDIs with nanofiber or smooth surfaces to investigate the effect of surface topography on implant performance. We observed in vitro that nanofiber surfaces supported fibroblast integration and quiescence, even in the presence of pro-fibrotic signals, compared to smooth surfaces. In rabbit eyes, GDIs with a nanofiber architecture were biocompatible, prevented hypotony, and provided a volumetric aqueous outflow comparable to commercially available GDIs, though with significantly reduced fibrotic encapsulation and expression of key fibrotic markers in the surrounding tissue. We propose that the physical cues provided by the surface of the nanofiber-based GDIs mimic healthy extracellular matrix structure, mitigating fibroblast activation and potentially extending functional GDI lifespan.
Collapse
Affiliation(s)
- Aditya Josyula
- Center for NanomedicineJohns Hopkins University School of MedicineBaltimoreMarylandUSA
- Department of Chemical and Biomolecular EngineeringJohns Hopkins UniversityBaltimoreMarylandUSA
| | - Ann Mozzer
- Center for NanomedicineJohns Hopkins University School of MedicineBaltimoreMarylandUSA
- Department of Ophthalmology, Wilmer Eye InstituteJohns Hopkins University School of MedicineBaltimoreMarylandUSA
| | - Julia Szeto
- Center for NanomedicineJohns Hopkins University School of MedicineBaltimoreMarylandUSA
- Department of Ophthalmology, Wilmer Eye InstituteJohns Hopkins University School of MedicineBaltimoreMarylandUSA
| | - Youlim Ha
- Center for NanomedicineJohns Hopkins University School of MedicineBaltimoreMarylandUSA
- Department of Chemical and Biomolecular EngineeringJohns Hopkins UniversityBaltimoreMarylandUSA
| | - Nicole Richmond
- Center for NanomedicineJohns Hopkins University School of MedicineBaltimoreMarylandUSA
- Department of BiologyJohns Hopkins UniversityBaltimoreMarylandUSA
| | - Seung Woo Chung
- Center for NanomedicineJohns Hopkins University School of MedicineBaltimoreMarylandUSA
- Department of Ophthalmology, Wilmer Eye InstituteJohns Hopkins University School of MedicineBaltimoreMarylandUSA
| | - Sri Vishnu Kiran Rompicharla
- Center for NanomedicineJohns Hopkins University School of MedicineBaltimoreMarylandUSA
- Department of Ophthalmology, Wilmer Eye InstituteJohns Hopkins University School of MedicineBaltimoreMarylandUSA
| | - Janani Narayan
- Center for NanomedicineJohns Hopkins University School of MedicineBaltimoreMarylandUSA
- Department of Chemical and Biomolecular EngineeringJohns Hopkins UniversityBaltimoreMarylandUSA
| | - Samiksha Ramesh
- Center for NanomedicineJohns Hopkins University School of MedicineBaltimoreMarylandUSA
- Department of Biomedical EngineeringJohns Hopkins University School of MedicineBaltimoreMarylandUSA
| | - Justin Hanes
- Center for NanomedicineJohns Hopkins University School of MedicineBaltimoreMarylandUSA
- Department of Chemical and Biomolecular EngineeringJohns Hopkins UniversityBaltimoreMarylandUSA
- Department of Ophthalmology, Wilmer Eye InstituteJohns Hopkins University School of MedicineBaltimoreMarylandUSA
- Department of Biomedical EngineeringJohns Hopkins University School of MedicineBaltimoreMarylandUSA
- Departments of Pharmacology and Molecular Sciences, Environmental Health Sciences, Oncology, and NeurosurgeryJohns Hopkins University School of MedicineBaltimoreMarylandUSA
| | - Laura Ensign
- Center for NanomedicineJohns Hopkins University School of MedicineBaltimoreMarylandUSA
- Department of Chemical and Biomolecular EngineeringJohns Hopkins UniversityBaltimoreMarylandUSA
- Department of Ophthalmology, Wilmer Eye InstituteJohns Hopkins University School of MedicineBaltimoreMarylandUSA
- Department of Biomedical EngineeringJohns Hopkins University School of MedicineBaltimoreMarylandUSA
- Departments of Pharmacology and Molecular Sciences, Infectious Diseases, Oncology, and Gynecology and ObstetricsJohns Hopkins University School of MedicineBaltimoreMarylandUSA
| | - Kunal Parikh
- Center for NanomedicineJohns Hopkins University School of MedicineBaltimoreMarylandUSA
- Department of Ophthalmology, Wilmer Eye InstituteJohns Hopkins University School of MedicineBaltimoreMarylandUSA
- Department of Biomedical EngineeringJohns Hopkins University School of MedicineBaltimoreMarylandUSA
- Center for Bioengineering Innovation & DesignJohns Hopkins UniversityBaltimoreMarylandUSA
| | - Ian Pitha
- Center for NanomedicineJohns Hopkins University School of MedicineBaltimoreMarylandUSA
- Department of Ophthalmology, Wilmer Eye InstituteJohns Hopkins University School of MedicineBaltimoreMarylandUSA
- Glaucoma Center of Excellence, Wilmer Eye InstituteJohns Hopkins University School of MedicineBaltimoreMarylandUSA
| |
Collapse
|
4
|
Siewert S, Kischkel S, Brietzke A, Kinzel L, Lindner T, Hinze U, Chichkov B, Schmidt W, Stiehm M, Grabow N, Guthoff RF, Schmitz KP, Stahnke T. Development of a Novel Valve-Controlled Drug-Elutable Microstent for Microinvasive Glaucoma Surgery: In Vitro and Preclinical In Vivo Studies. Transl Vis Sci Technol 2023; 12:4. [PMID: 36857065 PMCID: PMC9987165 DOI: 10.1167/tvst.12.3.4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/02/2023] Open
Abstract
Purpose Microinvasive glaucoma surgery (MIGS) has become an important treatment approach for primary open-angle glaucoma, although the safe and long-term effective lowering of intraocular pressure with currently available implants for MIGS is not yet achieved to a satisfactory extent. The study focusses on the development and in vitro and in vivo testing of a novel microstent for MIGS. Methods A silicone elastomer-based microstent was developed. Implants were manufactured using dip coating, fs-laser cutting, and spray coating. Within the current study no antifibrotic drug was loaded into the device. Sterilized microstents were analyzed in vitro regarding pressure-flow characteristics and biocompatibility. Six New Zealand white rabbits were implanted with a microstent draining the aqueous humor from the anterior chamber into the subconjunctival space. Drainage efficacy was evaluated using oculopressure tonometry as a transient glaucoma model. Noninvasive imaging was performed. Results Microstents were manufactured successfully and characterized in vitro. Implantation in vivo was successful for four animals with additional device fixation. Without additional fixation, dislocation of microstents was found in two animals. Safe and effective intraocular pressure reduction was observed for the four eyes with correctly implanted microstent during the 6-month trial period. Conclusions The described microstent represents an innovative treatment approach for MIGS. The incorporation of a selectively antifibrotic drug into the microstent drug-elutable coating will be addressed in future investigations. Translational Relevance The current preclinical study successfully provided proof of concept for our microstent for MIGS which is suitable for safe and effective intraocular pressure reduction and offers promising perspectives for the clinical management of glaucoma.
Collapse
Affiliation(s)
- Stefan Siewert
- Institute for ImplantTechnology and Biomaterials e.V., Rostock-Warnemünde, Germany
| | - Sabine Kischkel
- Institute for Biomedical Engineering, Rostock University Medical Center, Rostock, Germany
| | - Andreas Brietzke
- Institute for Biomedical Engineering, Rostock University Medical Center, Rostock, Germany
| | - Ludmila Kinzel
- Department of Ophthalmology, Rostock University Medical Center, Rostock, Germany
| | - Tobias Lindner
- Core Facility Multimodal Small Animal Imaging, Rostock University Medical Center, Rostock, Germany
| | - Ulf Hinze
- Institute of Quantum Optics, Faculty of Mathematics and Physics, Leibniz University Hannover, Hannover, Germany.,Laser nanoFab GmbH, Garbsen, Germany
| | - Boris Chichkov
- Institute of Quantum Optics, Faculty of Mathematics and Physics, Leibniz University Hannover, Hannover, Germany.,Laser nanoFab GmbH, Garbsen, Germany
| | - Wolfram Schmidt
- Institute for Biomedical Engineering, Rostock University Medical Center, Rostock, Germany
| | - Michael Stiehm
- Institute for ImplantTechnology and Biomaterials e.V., Rostock-Warnemünde, Germany
| | - Niels Grabow
- Institute for Biomedical Engineering, Rostock University Medical Center, Rostock, Germany
| | - Rudolf F Guthoff
- Department of Ophthalmology, Rostock University Medical Center, Rostock, Germany
| | - Klaus-Peter Schmitz
- Institute for ImplantTechnology and Biomaterials e.V., Rostock-Warnemünde, Germany.,Institute for Biomedical Engineering, Rostock University Medical Center, Rostock, Germany
| | - Thomas Stahnke
- Institute for ImplantTechnology and Biomaterials e.V., Rostock-Warnemünde, Germany.,Department of Ophthalmology, Rostock University Medical Center, Rostock, Germany
| |
Collapse
|
5
|
Ozkan J, Majzoub ME, Coroneo M, Thomas T, Willcox M. Comparative analysis of ocular surface tissue microbiome in human, mouse, rabbit, and guinea pig. Exp Eye Res 2021; 207:108609. [PMID: 33932398 DOI: 10.1016/j.exer.2021.108609] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Revised: 04/06/2021] [Accepted: 04/21/2021] [Indexed: 01/21/2023]
Abstract
Animal models are a critical element of ocular surface research for investigating therapeutic drops, surgical implants, and infection research. This study was a comparative analysis of the microbial communities on conjunctival tissue samples from humans compared to several commonly used laboratory animals (BALB/c mice, New Zealand white rabbits and IMVS colored stock guinea pigs). Microbial communities were analyzed by extracting total DNA from conjunctival tissue and sequencing the 16 S rRNA gene using the Illumina MiSeq platform. Sequences were quality filtered using the UNOISE pipeline in USEARCH and taxonomically classified using GTDB database. Sequences associated with blank extraction and sampling negative controls were removed with the decontam R software package prior to downstream analysis. There was a difference in the diversity measures of richness (P = 0.0124) and Shannon index (P = 0.0002) between humans and rabbits but not between human, mouse and guinea pigs. There was a difference between the human and any animal for bacterial community structure (P = 0.006). There was a higher degree of similarity between the bacterial composition of the human and mouse samples with each dominated by the phyla Proteobacteria and Firmicutes. The use of mouse models may be more appropriate for studies investigating changes to the ocular microbiome due to interventions such as application of antibiotics due to greater similarities in bacterial community structure and composition to humans.
Collapse
Affiliation(s)
- Jerome Ozkan
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia; Centre for Marine Science and Innovation and School of Biological, Earth and Environmental Sciences, University of New South Wales, Sydney, Australia.
| | - Marwan E Majzoub
- Centre for Marine Science and Innovation and School of Biological, Earth and Environmental Sciences, University of New South Wales, Sydney, Australia
| | - Minas Coroneo
- Department of Ophthalmology, Faculty of Medicine, University of New South Wales, Sydney, Australia
| | - Torsten Thomas
- Centre for Marine Science and Innovation and School of Biological, Earth and Environmental Sciences, University of New South Wales, Sydney, Australia
| | - Mark Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| |
Collapse
|