1
|
Guo R, Qi H, Amyar A, Cai X, Kucukseymen S, Haji-Valizadeh H, Rodriguez J, Paskavitz A, Pierce P, Goddu B, Thompson RB, Nezafat R. Quantification of changes in myocardial T 1 * values with exercise cardiac MRI using a free-breathing non-electrocardiograph radial imaging. Magn Reson Med 2022; 88:1720-1733. [PMID: 35691942 DOI: 10.1002/mrm.29346] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2021] [Revised: 05/09/2022] [Accepted: 05/16/2022] [Indexed: 11/11/2022]
Abstract
PURPOSE To develop and evaluate a free breathing non-electrocardiograph (ECG) myocardial T1 * mapping sequence using radial imaging to quantify the changes in myocardial T1 * between rest and exercise (T1 *reactivity ) in exercise cardiac MRI (Ex-CMR). METHODS A free-running T1 * sequence was developed using a saturation pulse followed by three Look-Locker inversion-recovery experiments. Each Look-Locker continuously acquired data as radial trajectory using a low flip-angle spoiled gradient-echo readout. Self-navigation was performed with a temporal resolution of ∼100 ms for retrospectively extracting respiratory motion. The mid-diastole phase for every cardiac cycle was retrospectively detected on the recorded electrocardiogram signal using an empirical model. Multiple measurements were performed to obtain mean value to reduce effects from the free-breathing acquisition. Finally, data acquired at both mid-diastole and end-expiration are picked and reconstructed by a low-rank plus sparsity constraint algorithm. The performance of this sequence was evaluated by simulations, phantoms, and in vivo studies at rest and after physiological exercise. RESULTS Numerical simulation demonstrated that changes in T1 * are related to the changes in T1 ; however, other factors such as breathing motion could influence T1 * measurements. Phantom T1 * values measured using free-running T1 * mapping sequence had good correlation with spin-echo T1 values and was insensitive to heart rate. In the Ex-CMR study, the measured T1 * reactivity was 10% immediately after exercise and declined over time. CONCLUSION The free-running T1 * mapping sequence allows free-breathing non-ECG quantification of changes in myocardial T1 * with physiological exercise. Although, absolute myocardial T1 * value is sensitive to various confounders such as B1 and B0 inhomogeneity, quantification of its change may be useful in revealing myocardial tissue properties with exercise.
Collapse
Affiliation(s)
- Rui Guo
- Department of Medicine, Cardiovascular Division, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| | - Haikun Qi
- School of Biomedical Engineering, ShanghaiTech University, Shanghai, China
| | - Amine Amyar
- Department of Medicine, Cardiovascular Division, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| | - Xiaoying Cai
- Department of Medicine, Cardiovascular Division, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA.,Siemens Medical Solutions USA, Inc., Boston, MA, USA
| | - Selcuk Kucukseymen
- Department of Medicine, Cardiovascular Division, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| | - Hassan Haji-Valizadeh
- Department of Medicine, Cardiovascular Division, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| | - Jennifer Rodriguez
- Department of Medicine, Cardiovascular Division, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| | - Amanda Paskavitz
- Department of Medicine, Cardiovascular Division, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| | - Patrick Pierce
- Department of Medicine, Cardiovascular Division, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| | - Beth Goddu
- Department of Medicine, Cardiovascular Division, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| | - Richard B Thompson
- Department of Biomedical Engineering, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Canada
| | - Reza Nezafat
- Department of Medicine, Cardiovascular Division, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| |
Collapse
|
2
|
Li Z, Xu X, Yang Y, Feng L. Repeatability and robustness of MP-GRASP T 1 mapping. Magn Reson Med 2022; 87:2271-2286. [PMID: 34971467 PMCID: PMC10061203 DOI: 10.1002/mrm.29131] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 12/03/2021] [Accepted: 12/06/2021] [Indexed: 12/14/2022]
Abstract
PURPOSE To demonstrate the repeatability of fast 3D T1 mapping using Magnetization-Prepared Golden-angle RAdial Sparse Parallel (MP-GRASP) MRI and its robustness to variation of imaging parameters including flip angle and spatial resolution in phantoms and the brain. THEORY AND METHODS Multiple imaging experiments were performed to (1) assess the robustness of MP-GRASP T1 mapping to B1 inhomogeneity using a single tube phantom filled with uniform MnCl2 liquid; (2) compare the repeatability of T1 mapping between MP-GRASP and inversion recovery-based spin-echo (IR-SE; over 12 scans), using a commercial T1MES phantom; (3) evaluate the longitudinal variation of T1 estimation using MP-GRASP with varying imaging parameters, including spatial resolution, flip angle, TR/TE, and acceleration rate, using the T1MES phantom (106 scans performed over a period of 12 months); and (4) evaluate the variation of T1 estimation using MP-GRASP with varying imaging parameters in the brain (24 scans in a single visit). In addition, the accuracy of MP-GRASP T1 mapping was also validated against IR-SE by performing linear correlation and calculating the Lin's concordance correlation coefficient (CCC). RESULTS MP-GRASP demonstrates good robustness to B1 inhomogeneity, with intra-slice variability below 1% in the single tube phantom experiment. The longitudinal variability is good both in the phantom (below 2.5%) and in the brain (below 2%) with varying imaging parameters. The T1 values estimated from MP-GRASP are accurate compared to that from the IR-SE imaging (R2 = 0.997, Lin's CCC = 0.996). CONCLUSION MP-GRASP shows excellent repeatability of T1 estimation over time, and it is also robust to variation of different imaging parameters evaluated in this study.
Collapse
Affiliation(s)
- Zhitao Li
- Department of Radiology, Stanford University, Palo Alto, California, United States
| | - Xiang Xu
- Biomedical Engineering and Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, United States
| | - Yang Yang
- Biomedical Engineering and Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, United States
| | - Li Feng
- Biomedical Engineering and Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, United States
| |
Collapse
|
3
|
Carr ME, Keenan KE, Rai R, Metcalfe P, Walker A, Holloway L. Determining the longitudinal accuracy and reproducibility of T 1 and T 2 in a 3T MRI scanner. J Appl Clin Med Phys 2021; 22:143-150. [PMID: 34562341 PMCID: PMC8598150 DOI: 10.1002/acm2.13432] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2021] [Revised: 08/17/2021] [Accepted: 09/07/2021] [Indexed: 11/09/2022] Open
Abstract
Purpose To determine baseline accuracy and reproducibility of T1 and T2 relaxation times over 12 months on a dedicated radiotherapy MRI scanner. Methods An International Society of Magnetic Resonance in Medicine/National Institute of Standards and Technology (ISMRM/NIST) System Phantom was scanned monthly on a 3T MRI scanner for 1 year. T1 was measured using inversion recovery (T1‐IR) and variable flip angle (T1‐VFA) sequences and T2 was measured using a multi‐echo spin echo (T2‐SE) sequence. For each vial in the phantom, accuracy errors (%bias) were determined by the relative differences in measured T1 and T2 times compared to reference values. Reproducibility was measured by the coefficient of variation (CV) of T1 and T2 measurements across monthly scans. Accuracy and reproducibility were mainly assessed on vials with relaxation times expected to be in physiological ranges at 3T. Results A strong linear correlation between measured and reference relaxation times was found for all sequences tested (R2 > 0.997). Baseline bias (and CV[%]) for T1‐IR, T1‐VFA and T2‐SE sequences were +2.0% (2.1), +6.5% (4.2), and +8.5% (1.9), respectively. Conclusions The accuracy and reproducibility of T1 and T2 on the scanner were considered sufficient for the sequences tested. No longitudinal trends of variation were deduced, suggesting less frequent measurements are required following the establishment of baselines.
Collapse
Affiliation(s)
- Madeline E Carr
- Centre for Medical and Radiation Physics, University of Wollongong, Wollongong, Australia.,Ingham Institute for Applied Medical Research, Liverpool, Australia.,Liverpool and Macarthur Cancer Therapy Centres, Sydney, Australia
| | - Kathryn E Keenan
- National Institute of Standards and Technology, Boulder, Colorado, USA
| | - Robba Rai
- Ingham Institute for Applied Medical Research, Liverpool, Australia.,Liverpool and Macarthur Cancer Therapy Centres, Sydney, Australia.,South Western Sydney Clinical School, University of New South Wales, Liverpool, Australia
| | - Peter Metcalfe
- Centre for Medical and Radiation Physics, University of Wollongong, Wollongong, Australia.,Ingham Institute for Applied Medical Research, Liverpool, Australia
| | - Amy Walker
- Centre for Medical and Radiation Physics, University of Wollongong, Wollongong, Australia.,Ingham Institute for Applied Medical Research, Liverpool, Australia.,Liverpool and Macarthur Cancer Therapy Centres, Sydney, Australia.,South Western Sydney Clinical School, University of New South Wales, Liverpool, Australia
| | - Lois Holloway
- Centre for Medical and Radiation Physics, University of Wollongong, Wollongong, Australia.,Ingham Institute for Applied Medical Research, Liverpool, Australia.,Liverpool and Macarthur Cancer Therapy Centres, Sydney, Australia.,South Western Sydney Clinical School, University of New South Wales, Liverpool, Australia.,Institute of Medical Physics, University of Sydney, Camperdown, Australia
| |
Collapse
|
4
|
Alabed S, Saunders L, Garg P, Shahin Y, Alandejani F, Rolf A, Puntmann VO, Nagel E, Wild JM, Kiely DG, Swift AJ. Myocardial T1-mapping and extracellular volume in pulmonary arterial hypertension: A systematic review and meta-analysis. Magn Reson Imaging 2021; 79:66-75. [PMID: 33745961 DOI: 10.1016/j.mri.2021.03.011] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 03/10/2021] [Accepted: 03/13/2021] [Indexed: 11/19/2022]
Abstract
INTRODUCTION Elevated myocardial T1-mapping and extracellular volume (ECV) measured on cardiac MR (CMR) imaging is associated with myocardial abnormalities such as oedema or fibrosis. This meta-analysis aims to provide a summary of T1-mapping and ECV values in pulmonary arterial hypertension (PAH) and compare their values with controls. METHODS We searched CENTRAL, MEDLINE, Embase, and Web of Science in August 2020. We included CMR studies reporting T1-mapping or ECV values in adults with any type of PAH. We calculated the mean difference of T1-values and ECV between PAH and controls. RESULTS We included 12 studies with 674 participants. T1-values were significantly higher in PAH with the highest mean difference (MD) recorded at the RV insertion points (RVIP) (108 milliseconds (ms), 95% confidence intervals (CI) 89 to 128), followed by the RV free wall (MD 91 ms, 95% CI 56 to 126). The pooled mean T1-value in PAH at the RVIP was 1084, 95% CI (1071 to 1097) measured using 1.5 Tesla Siemens systems. ECV was also higher in PAH with an MD of 7.5%, 95% CI (5.9 to 9.1) at the RV free wall. CONCLUSION T1 mapping values in PAH patients are on average 9% higher than healthy controls when assessed under the same conditions including the same MRI system, magnetic field strength or sequence used for acquisition. The highest T1 and ECV values are at the RVIP. T1 mapping and ECV values in PH are higher than the values reported in cardiomyopathies and were associated with poor RV function and RV dilatation.
Collapse
Affiliation(s)
- Samer Alabed
- Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, UK; Department of Clinical Radiology, Sheffield Teaching Hospitals, Sheffield, UK.
| | - Laura Saunders
- Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - Pankaj Garg
- Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - Yousef Shahin
- Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, UK; Department of Clinical Radiology, Sheffield Teaching Hospitals, Sheffield, UK
| | - Faisal Alandejani
- Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, UK
| | - Andreas Rolf
- Department of Cardiology, Kerckhoff-Heart Center, Bad Nauheim, Germany
| | - Valentina O Puntmann
- Institute for Experimental and Translational Cardiovascular Imaging, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Eike Nagel
- Institute for Experimental and Translational Cardiovascular Imaging, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Jim M Wild
- Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, UK; INSIGNEO, Institute for in silico medicine, University of Sheffield, UK
| | - David G Kiely
- Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, UK; Sheffield Pulmonary Vascular Disease Unit, Royal Hallamshire Hospital, Sheffield, UK
| | - Andrew J Swift
- Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, UK; Department of Clinical Radiology, Sheffield Teaching Hospitals, Sheffield, UK; Sheffield Pulmonary Vascular Disease Unit, Royal Hallamshire Hospital, Sheffield, UK
| |
Collapse
|
5
|
Crombé A, Buy X, Han F, Toupin S, Kind M. Assessment of Repeatability, Reproducibility, and Performances of T2 Mapping-Based Radiomics Features: A Comparative Study. J Magn Reson Imaging 2021; 54:537-548. [PMID: 33594768 DOI: 10.1002/jmri.27558] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Revised: 01/26/2021] [Accepted: 01/26/2021] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND Magnetic resonance imaging (MRI)-based radiomics features (RFs) quantify tumors radiological phenotypes but are sensitive to postprocessing parameters, including the intensity harmonization technique (IHT), while mappings enable objective quantitative assessment. PURPOSE To investigate whether T2 mapping could improve repeatability, reproducibility, and performances of radiomics compared to conventional T2-weighted imaging (T2WI). STUDY TYPE Prospective. SUBJECTS Twenty-six healthy adults. FIELD STRENGTH/SEQUENCE Respiratory-trigged radial turbo spin echo (TSE) multiecho T2 mapping (prototype) and conventional TSE T2WI of the abdomen were acquired twice at 1.5 T. ASSESSMENT T2 maps were reconstructed using a two-parameter exponential fitting model. Volumes-of-interest (VOIs) were manually drawn in six tissues: liver, kidney, pancreas, muscle, bone, and spleen. After co-registration, conventional T2WIs were processed with two IHTs (standardization [std] and histogram-matching [HM]) resulting in four paired input image types: initial T2WI, T2WIstd , T2WIHM , and T2-map. VOIs were propagated to extract 45 RFs from MRI-1 and MRI-2 of each image type (LIFEx, v5.10). STATISTICAL TESTS Influence of the input data type on RF values was evaluated with analysis of variance. RFs test-retest repeatability and reproducibility over multiple segmentations were evaluated with intra-class correlation coefficient (ICC). Correlations between k-means clusters and the six tissues depending on the RFs dataset were investigated with adjusted-Rand-index (ARI). RESULTS About 41 of 45 (91.1%) RFs were significantly influenced by the input image type (P values < 0.05), which was the most influential factor on repeatability of RFs (P-value < 0.05). Repeatability ICCs from T2-map displayed intermediate values between the initial T2WI (range: 0.407-0.736) and the T2WIHM (range: 0.724-0.817). The number of RFs with interobserver and intraobserver reproducibility ICCs ≥ 0.90 was 37/45 (82.2%) for T2WIHM , 33/45 (73.3%) for T2WIstd , 31/45 (68.9%) for T2 map, and 25/45 (55.6%) for the initial T2WI. T2 map provided the best tissue discrimination (ARI = 0.414 vs. 0.157 with T2WIHM ). DATA CONCLUSION T2 mapping provided RFs with moderate to substantial repeatability and reproducibility ICCs, along with the most preserved discriminative information. LEVEL OF EVIDENCE 1 TECHNICAL EFFICACY: 1.
Collapse
Affiliation(s)
- Amandine Crombé
- Department of Oncologic Imaging, Institut Bergonié, Comprehensive Cancer Center of Nouvelle-Aquitaine, Bordeaux, France.,Bordeaux University, Bordeaux, France.,Modelisation in Oncology (MOnc) Team, INRIA Bordeaux-Sud-Ouest, CNRS UMR 5251, Talence, France
| | - Xavier Buy
- Department of Oncologic Imaging, Institut Bergonié, Comprehensive Cancer Center of Nouvelle-Aquitaine, Bordeaux, France
| | - Fei Han
- Siemens Medical Solutions USA, Los Angeles, California, USA
| | | | - Michèle Kind
- Department of Oncologic Imaging, Institut Bergonié, Comprehensive Cancer Center of Nouvelle-Aquitaine, Bordeaux, France
| |
Collapse
|
6
|
Guo R, Cai X, Kucukseymen S, Rodriguez J, Paskavitz A, Pierce P, Goddu B, Thompson RB, Nezafat R. Free-breathing simultaneous myocardial T 1 and T 2 mapping with whole left ventricle coverage. Magn Reson Med 2020; 85:1308-1321. [PMID: 33078443 DOI: 10.1002/mrm.28506] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Revised: 08/13/2020] [Accepted: 08/14/2020] [Indexed: 01/20/2023]
Abstract
PURPOSE To develop a free-breathing sequence, that is, Multislice Joint T1 -T2 , for simultaneous measurement of myocardial T1 and T2 for multiple slices to achieve whole left-ventricular coverage. METHODS Multislice Joint T1 -T2 adopts slice-interleaved acquisition to collect 10 single-shot electrocardiogram-triggered images for each slice prepared by saturation and T2 preparation to simultaneously estimate myocardial T1 and T2 and achieve whole left-ventricular coverage. Prospective slice-tracking using a respiratory navigator and retrospective image registration are used to reduce through-plane and in-plane motion, respectively. Multislice Joint T1 -T2 was validated through numerical simulations and phantom and in vivo experiments, and compared with saturation-recovery single-shot acquisition and T2 -prepared balanced Steady-State Free Precession (T2 -prep SSFP) sequences. RESULTS Phantom T1 and T2 from Multislice Joint T1 -T2 had good accuracy and precision, and were insensitive to heart rate. Multislice Joint T1 -T2 yielded T1 and T2 maps of nine left-ventricular slices in 1.4 minutes. The mean left-ventricular T1 difference between saturation-recovery single-shot acquisition and Multislice Joint T1 -T2 across healthy subjects and patients was 191 ms (1564 ± 60 ms versus 1373 ± 50 ms; P < .05) and 111 ms (1535 ± 49 ms vs 1423 ± 49 ms; P < .05), respectively. The mean difference in left-ventricular T2 between T2 -prep SSFP and Multislice Joint T1 -T2 across healthy subjects and patients was -6.3 ms (42.4 ± 1.4 ms vs 48.7 ± 2.5; P < .05) and -5.7 ms (41.6 ± 2.5 ms vs 47.3 ± 2.7; P < .05), respectively. CONCLUSION Multislice Joint T1 -T2 enables quantification of whole left-ventricular T1 and T2 during free breathing within a clinically feasible scan time of less than 2 minutes.
Collapse
Affiliation(s)
- Rui Guo
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA
| | - Xiaoying Cai
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA.,Siemens Medical Solutions USA, Inc., Boston, Massachusetts, USA
| | - Selcuk Kucukseymen
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA
| | - Jennifer Rodriguez
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA
| | - Amanda Paskavitz
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA
| | - Patrick Pierce
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA
| | - Beth Goddu
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA
| | - Richard B Thompson
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada
| | - Reza Nezafat
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
7
|
Wiesmueller M, Wuest W, Heiss R, Treutlein C, Uder M, May MS. Cardiac T2 mapping: robustness and homogeneity of standardized in-line analysis. J Cardiovasc Magn Reson 2020; 22:39. [PMID: 32460852 PMCID: PMC7254724 DOI: 10.1186/s12968-020-00619-x] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2019] [Accepted: 03/23/2020] [Indexed: 01/22/2023] Open
Abstract
BACKGROUND AND PURPOSE Interpretation of T2 values remains difficult due to limited comparability across hardware and software systems and the lack of validated measurement recommendations for the number and orientation of mandatory slices. Our aims were to provide a standardized comparison of intra- and inter-individual T2 values in the short and long axes and to investigate inter-scanner reproducibility. METHOD AND MATERIALS Ninety cardiovascular magnetic resonance (CMR) studies in 30 healthy subjects were performed with three identical 1.5 T CMR scanners (same hardware and software) using a balanced steady-state free precession (bSSFP) gradient echo sequence in three short axis (SAx) and three long axis (LAx) views. A commercially available T2 mapping software package of the latest generation with automatic in-line motion correction was used for acquisition. Regions of interest were manually drawn in each of the 16 myocardial segments according to the American Heart Association (AHA) model in three SAx and three LAx acquisitions. Analysis of inter-scanner, inter-segmental, intra-segmental, inter-regional and inter-level differences was performed. RESULTS Inter-scanner reproducibility was high and the mean myocardial T2 value for all evaluated segments was 45.7 ± 3.4 ms. Significant inter-segmental variations of mean T2 values were found. Mean intra-segmental T2 values were comparable between LAx and SAx acquisitions in 72%. Significantly higher T2 values were found in apical segments and a significant disparity among different regions was found for SAx and LAx orientations. CONCLUSION Standardized cardiac T2 mapping is highly reproducible on identical CMR systems. T2 values vary significantly between single heart segments, regions, levels, and axes in young, healthy subjects.
Collapse
Affiliation(s)
- Marco Wiesmueller
- Department of Radiology, University Hospital Erlangen, Maximiliansplatz 3, 91054, Erlangen, Germany.
| | - Wolfgang Wuest
- Department of Radiology, University Hospital Erlangen, Maximiliansplatz 3, 91054, Erlangen, Germany
| | - Rafael Heiss
- Department of Radiology, University Hospital Erlangen, Maximiliansplatz 3, 91054, Erlangen, Germany
| | - Christoph Treutlein
- Department of Radiology, University Hospital Erlangen, Maximiliansplatz 3, 91054, Erlangen, Germany
| | - Michael Uder
- Department of Radiology, University Hospital Erlangen, Maximiliansplatz 3, 91054, Erlangen, Germany
| | - Matthias Stefan May
- Department of Radiology, University Hospital Erlangen, Maximiliansplatz 3, 91054, Erlangen, Germany
| |
Collapse
|