Wu LY, Lin WP, Wu R, White L, Abass A. FEA-Based Stress-Strain Barometers as Forecasters for Corneal Refractive Power Change in Orthokeratology. Bioengineering (Basel) 2024; 11:166. [PMID: 38391654 PMCID: PMC10886155 DOI: 10.3390/bioengineering11020166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 02/04/2024] [Accepted: 02/06/2024] [Indexed: 02/24/2024] Open
Abstract
PURPOSE To improve the effectivity of patient-specific finite element analysis (FEA) to predict refractive power change (RPC) in rigid Ortho-K contact lens fitting. Novel eyelid boundary detection is introduced to the FEA model to better model the effects of the lid on lens performance, and stress and strain outcomes are investigated to identify the most effective FEA components to use in modelling. METHODS The current study utilises fully anonymised records of 249 eyes, 132 right eyes, and 117 left eyes from subjects aged 14.1 ± 4.0 years on average (range 9 to 38 years), which were selected for secondary analysis processing. A set of custom-built MATLAB codes was built to automate the process from reading Medmont E300 height and distance files to processing and displaying FEA stress and strain outcomes. Measurements from before and after contact lens wear were handled to obtain the corneal surface change in shape and power. Tangential refractive power maps were constructed from which changes in refractive power pre- and post-Ortho-K wear were determined as the refractive power change (RPC). A total of 249 patient-specific FEA with innovative eyelid boundary detection and 3D construction analyses were automatically built and run for every anterior eye and lens combination while the lens was located in its clinically detected position. Maps of four stress components: contact pressure, Mises stress, pressure, and maximum principal stress were created in addition to maximum principal logarithmic strain maps. Stress and strain components were compared to the clinical RPC maps using the two-dimensional (2D) normalised cross-correlation and structural similarity (SSIM) index measure. RESULTS On the one hand, the maximum principal logarithmic strain recorded the highest moderate 2D cross-correlation area of 8.6 ± 10.3%, and contact pressure recorded the lowest area of 6.6 ± 9%. Mises stress recorded the second highest moderate 2D cross-correlation area with 8.3 ± 10.4%. On the other hand, when the SSIM index was used to compare the areas that were most similar to the clinical RPC, maximum principal stress was the most similar, with an average strong similarity percentage area of 26.5 ± 3.3%, and contact pressure was the least strong similarity area of 10.3 ± 7.3%. Regarding the moderate similarity areas, all components were recorded at around 34.4% similarity area except the contact pressure, which was down to 32.7 ± 5.8%. CONCLUSIONS FEA is an increasingly effective tool in being able to predict the refractive outcome of Ortho-K treatment. Its accuracy depends on identifying which clinical and modelling metrics contribute to the most accurate prediction of RPC with minimal ocular complications. In terms of clinical metrics, age, Intra-ocular pressure (IOP), central corneal thickness (CCT), surface topography, lens decentration and the 3D eyelid effect are all important for effective modelling. In terms of FEA components, maximum principal stress was found to be the best FEA barometer that can be used to predict the performance of Ortho-K lenses. In contrast, contact pressure provided the worst stress performance. In terms of strain, the maximum principal logarithmic strain was an effective strain barometer.
Collapse
Affiliation(s)
- Lo-Yu Wu
- Department of Power Mechanical Engineering, Nation Tsing Hua University, Hsinchu 300, Taiwan
- Research and Development Center, Brighten Optix Corporation, Taipei 111, Taiwan
| | - Wen-Pin Lin
- Research and Development Center, Brighten Optix Corporation, Taipei 111, Taiwan
- Department of Optometry, University of Kang Ning, Taipei 114, Taiwan
| | - Richard Wu
- Research and Development Center, Brighten Optix Corporation, Taipei 111, Taiwan
- College of Optometry, Pacific University, Forest Grove, OR 97116, USA
| | - Lynn White
- Research and Development Department, LWVision, Leicester LE18 1DF, UK
| | - Ahmed Abass
- Department of Materials, Design and Manufacturing Engineering, School of Engineering, University of Liverpool, Liverpool L69 3GH, UK
| |
Collapse
|
2
|
Jaarsma-Coes MG, Klaassen L, Marinkovic M, Luyten GPM, Vu THK, Ferreira TA, Beenakker JWM. Magnetic Resonance Imaging in the Clinical Care for Uveal Melanoma Patients-A Systematic Review from an Ophthalmic Perspective. Cancers (Basel) 2023; 15:cancers15112995. [PMID: 37296958 DOI: 10.3390/cancers15112995] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 05/24/2023] [Accepted: 05/26/2023] [Indexed: 06/12/2023] Open
Abstract
Conversely to most tumour types, magnetic resonance imaging (MRI) was rarely used for eye tumours. As recent technical advances have increased ocular MRI's diagnostic value, various clinical applications have been proposed. This systematic review provides an overview of the current status of MRI in the clinical care of uveal melanoma (UM) patients, the most common eye tumour in adults. In total, 158 articles were included. Two- and three-dimensional anatomical scans and functional scans, which assess the tumour micro-biology, can be obtained in routine clinical setting. The radiological characteristics of the most common intra-ocular masses have been described extensively, enabling MRI to contribute to diagnoses. Additionally, MRI's ability to non-invasively probe the tissue's biological properties enables early detection of therapy response and potentially differentiates between high- and low-risk UM. MRI-based tumour dimensions are generally in agreement with conventional ultrasound (median absolute difference 0.5 mm), but MRI is considered more accurate in a subgroup of anteriorly located tumours. Although multiple studies propose that MRI's 3D tumour visualisation can improve therapy planning, an evaluation of its clinical benefit is lacking. In conclusion, MRI is a complementary imaging modality for UM of which the clinical benefit has been shown by multiple studies.
Collapse
Affiliation(s)
- Myriam G Jaarsma-Coes
- Department of Ophthalmology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
- Department of Radiology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
| | - Lisa Klaassen
- Department of Ophthalmology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
- Department of Radiology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
- Department of Radiation Oncology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
| | - Marina Marinkovic
- Department of Ophthalmology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
| | - Gregorius P M Luyten
- Department of Ophthalmology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
| | - T H Khanh Vu
- Department of Ophthalmology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
| | - Teresa A Ferreira
- Department of Radiology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
| | - Jan-Willem M Beenakker
- Department of Ophthalmology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
- Department of Radiology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
- Department of Radiation Oncology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
| |
Collapse
|
3
|
Jacobs SM, Versteeg E, van der Kolk AG, Visser LNC, Oliveira ÍAF, van Maren E, Klomp DWJ, Siero JCW. Image quality and subject experience of quiet T1-weighted 7-T brain imaging using a silent gradient coil. Eur Radiol Exp 2022; 6:36. [PMID: 36042139 PMCID: PMC9428090 DOI: 10.1186/s41747-022-00293-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Accepted: 06/16/2022] [Indexed: 11/17/2022] Open
Abstract
Objectives Acoustic noise in magnetic resonance imaging (MRI) negatively impacts patients. We assessed a silent gradient coil switched at 20 kHz combined with a T1-weighted magnetisation prepared rapid gradient-echo (MPRAGE) sequence at 7 T. Methods Five healthy subjects (21–29 years; three females) without previous 7-T MRI experience underwent both a quiet MPRAGE (Q-MPRAGE) and conventional MPRAGE (C-MPRAGE) sequence twice. Image quality was assessed quantitatively, and qualitatively by two neuroradiologists. Sound level was measured objectively and rated subjectively on a 0 to 10 scale by all subjects immediately following each sequence and after the whole examination (delayed). All subjects also reported comfort level, overall experience and willingness to undergo the sequence again. Results Compared to C-MPRAGE, Q-MPRAGE showed higher signal-to-noise ratio (10%; p = 0.012) and lower contrast-to-noise ratio (20%; p < 0.001) as well as acceptable to good image quality. Q-MPRAGE produced 27 dB lower sound level (76 versus 103 dB). Subjects reported lower sound level for Q-MPRAGE both immediate (4.4 ± 1.4 versus 6.4 ± 1.3; p = 0.007) and delayed (4.6 ± 1.4 versus 6.3 ± 1.3; p = 0.005), while they rated comfort level (7.4 ± 1.0 versus 6.1 ± 1.7; p = 0.016) and overall experience (7.6 ± 1.0 versus 6.0 ± 0.9; p = 0.005) higher. Willingness to undergo the sequence again was also higher, however not significantly (8.1 ± 1.0 versus 7.2 ± 1.3; p = 0.066). Conclusion Q-MPRAGE using a silent gradient coil reduced sound level by 27 dB compared to C-MPRAGE at 7 T while featuring acceptable-to-good image quality and a quieter and more pleasant subject experience.
Collapse
Affiliation(s)
- Sarah M Jacobs
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, the Netherlands.
| | - Edwin Versteeg
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, the Netherlands.
| | - Anja G van der Kolk
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, the Netherlands.,Department of Medical Imaging, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Leonie N C Visser
- Department of Neurology, Alzheimer Center Amsterdam, Amsterdam Neuroscience, Vrije Universiteit Amsterdam, Amsterdam UMC, Amsterdam, the Netherlands.,Division of Clinical Geriatrics, Department of Neurobiology, Care Sciences and Society, Center for Alzheimer Research, Karolinska Institute, Stockholm, Sweden
| | - Ícaro A F Oliveira
- Spinoza Centre for Neuroimaging Amsterdam, Amsterdam, the Netherlands.,Experimental and Applied Psychology, VU University, Amsterdam, the Netherlands
| | - Emiel van Maren
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Dennis W J Klomp
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Jeroen C W Siero
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, the Netherlands.,Spinoza Centre for Neuroimaging Amsterdam, Amsterdam, the Netherlands
| |
Collapse
|
4
|
Sims JR, Chen AM, Sun Z, Deng W, Colwell NA, Colbert MK, Zhu J, Sainulabdeen A, Faiq MA, Bang JW, Chan KC. Role of Structural, Metabolic, and Functional MRI in Monitoring Visual System Impairment and Recovery. J Magn Reson Imaging 2021; 54:1706-1729. [PMID: 33009710 PMCID: PMC8099039 DOI: 10.1002/jmri.27367] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Revised: 08/24/2020] [Accepted: 08/27/2020] [Indexed: 12/13/2022] Open
Abstract
The visual system, consisting of the eyes and the visual pathways of the brain, receives and interprets light from the environment so that we can perceive the world around us. A wide variety of disorders can affect human vision, ranging from ocular to neurologic to systemic in nature. While other noninvasive imaging techniques such as optical coherence tomography and ultrasound can image particular sections of the visual system, magnetic resonance imaging (MRI) offers high resolution without depth limitations. MRI also gives superior soft-tissue contrast throughout the entire pathway compared to computed tomography. By leveraging different imaging sequences, MRI is uniquely capable of unveiling the intricate processes of ocular anatomy, tissue physiology, and neurological function in the human visual system from the microscopic to macroscopic levels. In this review we discuss how structural, metabolic, and functional MRI can be used in the clinical assessment of normal and pathologic states in the anatomic structures of the visual system, including the eyes, optic nerves, optic chiasm, optic tracts, visual brain nuclei, optic radiations, and visual cortical areas. We detail a selection of recent clinical applications of MRI at each position along the visual pathways, including the evaluation of pathology, plasticity, and the potential for restoration, as well as its limitations and key areas of ongoing exploration. Our discussion of the current and future developments in MR ocular and neuroimaging highlights its potential impact on our ability to understand visual function in new detail and to improve our protection and treatment of anatomic structures that are integral to this fundamental sensory system. LEVEL OF EVIDENCE 3: TECHNICAL EFFICACY STAGE 3: .
Collapse
Affiliation(s)
- Jeffrey R. Sims
- Department of Ophthalmology, NYU Grossman School of Medicine, NYU Langone Health, New York University, New York, New York, USA
| | - Anna M. Chen
- Department of Ophthalmology, NYU Grossman School of Medicine, NYU Langone Health, New York University, New York, New York, USA
- Sackler Institute of Graduate Biomedical Sciences, NYU Grossman School of Medicine, NYU Langone Health, New York University, New York, New York, USA
| | - Zhe Sun
- Department of Ophthalmology, NYU Grossman School of Medicine, NYU Langone Health, New York University, New York, New York, USA
- Sackler Institute of Graduate Biomedical Sciences, NYU Grossman School of Medicine, NYU Langone Health, New York University, New York, New York, USA
| | - Wenyu Deng
- Department of Ophthalmology, NYU Grossman School of Medicine, NYU Langone Health, New York University, New York, New York, USA
| | - Nicole A. Colwell
- Department of Ophthalmology, NYU Grossman School of Medicine, NYU Langone Health, New York University, New York, New York, USA
| | - Max K. Colbert
- Department of Ophthalmology, NYU Grossman School of Medicine, NYU Langone Health, New York University, New York, New York, USA
| | - Jingyuan Zhu
- Department of Ophthalmology, NYU Grossman School of Medicine, NYU Langone Health, New York University, New York, New York, USA
- Department of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China
| | - Anoop Sainulabdeen
- Department of Ophthalmology, NYU Grossman School of Medicine, NYU Langone Health, New York University, New York, New York, USA
- Department of Surgery and Radiology, College of Veterinary and Animal Sciences, Kerala Veterinary and Animal Sciences University, Thrissur, India
| | - Muneeb A. Faiq
- Department of Ophthalmology, NYU Grossman School of Medicine, NYU Langone Health, New York University, New York, New York, USA
| | - Ji Won Bang
- Department of Ophthalmology, NYU Grossman School of Medicine, NYU Langone Health, New York University, New York, New York, USA
| | - Kevin C. Chan
- Department of Ophthalmology, NYU Grossman School of Medicine, NYU Langone Health, New York University, New York, New York, USA
- Sackler Institute of Graduate Biomedical Sciences, NYU Grossman School of Medicine, NYU Langone Health, New York University, New York, New York, USA
- Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York University, New York, New York, USA
- Neuroscience Institute, NYU Grossman School of Medicine, NYU Langone Health, New York University, New York, New York, USA
- Center for Neural Science, College of Arts and Science, New York University, New York, New York, USA
| |
Collapse
|
5
|
Sandberg JK, Young VA, Yuan J, Hargreaves BA, Wishah F, Vasanawala SS. Zero echo time pediatric musculoskeletal magnetic resonance imaging: initial experience. Pediatr Radiol 2021; 51:2549-2560. [PMID: 34156504 DOI: 10.1007/s00247-021-05125-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Revised: 03/24/2021] [Accepted: 06/10/2021] [Indexed: 11/30/2022]
Abstract
BACKGROUND Projection radiography (XR) is often supplemented by both CT (to evaluate osseous structures with ionizing radiation) and MRI (for marrow and soft-tissue assessment). Zero echo time (ZTE) MR imaging produces a "CT-like" osseous contrast that might obviate CT. OBJECTIVE This study investigated our institution's initial experience in implementing an isotropic ZTE MR imaging sequence for pediatric musculoskeletal examinations. MATERIALS AND METHODS Pediatric patients referred for extremity MRI at 3 tesla (T) underwent ZTE MR imaging to yield images with contrast similar to that of CT. A radiograph-like image was also created with ray-sum image processing. We assessed ZTE-CT/XR anatomical image quality (Sanat) from 0 (nondiagnostic) to 5 (outstanding). Further, we made image comparisons on a 5-point scale (Scomp) (range of -2 = conventional CT/XR greater anatomical delineation to +2 = ZTE-CT/XR greater anatomical delineation; 0=same) for three cohorts: (1) ZTE-XR to conventional radiography, (2) ZTE-CT to conventional CT and (3) pathological lesion assessment on ZTE-XR to conventional radiography. We measured cortical thickness of ZTE-XR and ZTE-CT and compared these with conventional imaging. We calculated confidence interval of proportions, Wilcoxon rank sum test and intraclass correlation coefficients for inter-reader agreement. RESULTS Cohorts 1, 2 and 3 consisted of 40, 20 and 35 cases, respectively (age range 0.6-23.0 years). ZTE-CT versus CT and ZTE-XR versus radiography of cortical thicknesses were not significantly different (P=0.55 and P=0.31, respectively). Cortical delineation was rated diagnostic or better (score of 3, 4 or 5) in all cases (confidence interval of proportions = 100%) for ZTE-CT/XR. Similarly, intramedullary cavity delineation was rated diagnostic or better in all cases for ZTE-CT, and ZTE-XR was at least diagnostic in 58-63% of cases. For cohort 2, cortex and intramedullary cavity Scomp for ZTE-CT was comparable to those of conventional CT, with confidence interval of proportion (sum of score of -1 to +2) of 93-100% and 95%, respectively. Pathology visualized on ZTE-CT/XR was comparable; Scomp confidence interval of proportions was 95%/97-100%, with improved delineation of non-displaced fractures on ZTE-XR. Readers had moderate to near-perfect intraclass correlation coefficient (range=0.60-0.93). CONCLUSION Implementation of a diagnostic-quality ZTE MRI sequence in the pediatric population is feasible and can be performed as a complementary pulse sequence to enhance musculoskeletal MRI studies. Compared to conventional CT, ZTE has comparable cortical delineation, intramedullary cavity and pathology visualization. While not intended as a replacement for conventional radiography, ZTE-XR provides similar visualization of pathology.
Collapse
Affiliation(s)
- Jesse K Sandberg
- Department of Radiology, Stanford University School of Medicine, 725 Welch Road, Room 1844, Stanford, CA, 94305, USA.
| | - Victoria A Young
- Department of Radiology, Stanford University School of Medicine, 725 Welch Road, Room 1844, Stanford, CA, 94305, USA
| | - Jianmin Yuan
- Department of Radiology, Stanford University School of Medicine, 725 Welch Road, Room 1844, Stanford, CA, 94305, USA
| | - Brian A Hargreaves
- Department of Radiology, Stanford University School of Medicine, 725 Welch Road, Room 1844, Stanford, CA, 94305, USA
| | - Fidaa Wishah
- Department of Radiology, Stanford University School of Medicine, 725 Welch Road, Room 1844, Stanford, CA, 94305, USA
| | - Shreyas S Vasanawala
- Department of Radiology, Stanford University School of Medicine, 725 Welch Road, Room 1844, Stanford, CA, 94305, USA
| |
Collapse
|
6
|
Niendorf T, Beenakker JWM, Langner S, Erb-Eigner K, Bach Cuadra M, Beller E, Millward JM, Niendorf TM, Stachs O. Ophthalmic Magnetic Resonance Imaging: Where Are We (Heading To)? Curr Eye Res 2021; 46:1251-1270. [PMID: 33535828 DOI: 10.1080/02713683.2021.1874021] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Magnetic resonance imaging of the eye and orbit (MReye) is a cross-domain research field, combining (bio)physics, (bio)engineering, physiology, data sciences and ophthalmology. A growing number of reports document technical innovations of MReye and promote their application in preclinical research and clinical science. Realizing the progress and promises, this review outlines current trends in MReye. Examples of MReye strategies and their clinical relevance are demonstrated. Frontier applications in ocular oncology, refractive surgery, ocular muscle disorders and orbital inflammation are presented and their implications for explorations into ophthalmic diseases are provided. Substantial progress in anatomically detailed, high-spatial resolution MReye of the eye, orbit and optic nerve is demonstrated. Recent developments in MReye of ocular tumors are explored, and its value for personalized eye models derived from machine learning in the treatment planning of uveal melanoma and evaluation of retinoblastoma is highlighted. The potential of MReye for monitoring drug distribution and for improving treatment management and the assessment of individual responses is discussed. To open a window into the eye and into (patho)physiological processes that in the past have been largely inaccessible, advances in MReye at ultrahigh magnetic field strengths are discussed. A concluding section ventures a glance beyond the horizon and explores future directions of MReye across multiple scales, including in vivo electrolyte mapping of sodium and other nuclei. This review underscores the need for the (bio)medical imaging and ophthalmic communities to expand efforts to find solutions to the remaining unsolved problems and technical obstacles of MReye, with the objective to transfer methodological advancements driven by MR physics into genuine clinical value.
Collapse
Affiliation(s)
- Thoralf Niendorf
- MRI.TOOLS GmbH, Berlin, Germany.,Berlin Ultrahigh Field Facility, Max Delbrueck Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Jan-Willem M Beenakker
- Department of Ophthalmology and Department of Radiology, Leiden University Medical Centre, Leiden, The Netherlands
| | - Sönke Langner
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany
| | - Katharina Erb-Eigner
- Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität Zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Meritxell Bach Cuadra
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland.,Department of Radiology, Lausanne University and University Hospital, Lausanne, Switzerland
| | - Ebba Beller
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany
| | - Jason M Millward
- Berlin Ultrahigh Field Facility, Max Delbrueck Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | | | - Oliver Stachs
- Department Life, Light & Matter, University Rostock, Rostock, Germany.,Department of Ophthalmology, Rostock University Medical Center, Rostock, Germany
| |
Collapse
|
7
|
|
8
|
The Evaluation of Optic Nerves Using 7 Tesla "Silent" Zero Echo Time Imaging in Patients with Leber's Hereditary Optic Neuropathy with or without Idebenone Treatment. J Clin Med 2020; 9:jcm9041112. [PMID: 32295018 PMCID: PMC7230870 DOI: 10.3390/jcm9041112] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Revised: 04/08/2020] [Accepted: 04/09/2020] [Indexed: 11/16/2022] Open
Abstract
Magnetic Resonance Imaging (MRI) of the Optic Nerve is difficult due to the fine extended nature of the structure, strong local magnetic field distortions induced by anatomy, and large motion artefacts associated with eye movement. To address these problems we used a Zero Echo Time (ZTE) MRI sequence with an Adiabatic SPectral Inversion Recovery (ASPIR) fat suppression pulse which also imbues the images with Magnetisation Transfer contrast. We investigated an application of the sequence for imaging the optic nerve in subjects with Leber's hereditary optic neuropathy (LHON). Of particular note is the sequence's near-silent operation, which can enhance image quality of the optic nerve by reducing the occurrence of involuntary saccades induced during Magnetic Resonance (MR) scanning.
Collapse
|