1
|
Guo Y, Liu Z, Feng S, Cai H, Zhang Q. Clinical Viability of an Active Spot Scanning Beam Delivery System With a Newly Developed Carbon-Ion Treatment Planning System. Adv Radiat Oncol 2024; 9:101503. [PMID: 38883996 PMCID: PMC11177064 DOI: 10.1016/j.adro.2024.101503] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Accepted: 01/19/2024] [Indexed: 06/18/2024] Open
Abstract
Purpose Although active spot scanning irradiation technique is theoretically superior to passive-scattered broad beam irradiation with respect to normal tissue sparing, corroborations of the clinical benefit of carbon-ion spot scanning have remained scarce. This study aims to investigate the feasibility and clinical implementation of an active spot scanning beam calculation algorithm in a homemade carbon-ion treatment planning system by comparing it with a conventional passive uniform scanning technique. Methods and Materials Carbon-ion plans were initially formulated using spot/uniform scanning methods in 22 participants enrolled in a prospective observational clinical trial. Subsequently, 2 additional plans were designed, resulting in 3 carbon-ion plans for each participant: uniform and spot scanning with miniridge filters of 2 mm and 4 mm, respectively. Results The findings revealed no significant differences in dose homogeneity; however, significant differences in dose conformity were found between the active and passive scanning plans. For dose drop-off outside the target volume, the average gradient index values were 1.94 (95% CI, 1.79%-2.09%), 1.87 (95% CI, 1.73%-2.01%), and 3.20 (95% CI, 2.80%-3.61%) for the miniridge filters of 2 mm and 4 mm, and uniform scanning plans, respectively. The pretreatment tumor volume was 124.7 cm3 (range, 54.2-234 cm3), and the average shrinkage observed was 38.4% (95% CI, 17.6%-59.4%). Seven participants experienced grade 1 acute toxicity, and 4 experienced grade 2 acute toxicity. However, none of the patients developed grade 3 acute toxicity. Conclusions Increasing evidence suggests that potential clinical advantages of spot scanning delivery underlie its technical characteristics. As one among the few institutions currently using carbon-ion radiation therapy, the investigation also provides promising safety and efficacy outcomes from the initial groups of treated participants, thereby contributing to the established clinical evidence supporting the effectiveness and superiority of carbon-ion therapy.
Collapse
Affiliation(s)
- Yixiao Guo
- Department of Radiation Oncology, Gansu Provincial Hospital, Lanzhou, P.R. China
| | - Zhiqiang Liu
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, Gansu, P.R. China
| | - Shifang Feng
- Department of Radiation Oncology, Gansu Provincial Hospital, Lanzhou, P.R. China
| | - Hongyi Cai
- Department of Radiation Oncology, Gansu Provincial Hospital, Lanzhou, P.R. China
| | - Qiuning Zhang
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, Gansu, P.R. China
| |
Collapse
|
2
|
Chagas Saraiva CW, Cardoso SC, Groppo DP, De Salles AAF, de Ávila LF, Ribeiro da Rosa LA. Correction: Gamma Knife radiosurgery for vestibular schwannomas: Evaluation of planning using the sphericity degree of the target volume. PLoS One 2024; 19:e0303715. [PMID: 38722853 PMCID: PMC11081239 DOI: 10.1371/journal.pone.0303715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/13/2024] Open
Abstract
[This corrects the article DOI: 10.1371/journal.pone.0225638.].
Collapse
|
3
|
Sümer E, Tek E, Türe OA, Şengöz M, Dinçer A, Özcan A, Pamir MN, Özduman K, Ozturk-Isik E. The effect of tumor shape irregularity on Gamma Knife treatment plan quality and treatment outcome: an analysis of 234 vestibular schwannomas. Sci Rep 2022; 12:21809. [PMID: 36528740 PMCID: PMC9759589 DOI: 10.1038/s41598-022-25422-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Accepted: 11/29/2022] [Indexed: 12/23/2022] Open
Abstract
The primary aim of Gamma Knife (GK) radiosurgery is to deliver high-dose radiation precisely to a target while conforming to the target shape. In this study, the effects of tumor shape irregularity (TSI) on GK dose-plan quality and treatment outcomes were analyzed in 234 vestibular schwannomas. TSI was quantified using seven different metrics including volumetric index of sphericity (VioS). GK treatment plans were created on a single GK-Perfexion/ICON platform. The plan quality was measured using selectivity index (SI), gradient index (GI), Paddick's conformity index (PCI), and efficiency index (EI). Correlation and linear regression analyses were conducted between shape irregularity features and dose plan indices. Machine learning was employed to identify the shape feature that predicted dose plan quality most effectively. The treatment outcome analysis including tumor growth control and serviceable hearing preservation at 2 years, were conducted using Cox regression analyses. All TSI features correlated significantly with the dose plan indices (P < 0.0012). With increasing tumor volume, vestibular schwannomas became more spherical (P < 0.05) and the dose plan indices varied significantly between tumor volume subgroups (P < 0.001 and P < 0.01). VioS was the most effective predictor of GK indices (P < 0.001) and we obtained 89.36% accuracy (79.17% sensitivity and 100% specificity) for predicting PCI. Our results indicated that TSI had significant effects on the plan quality however did not adversely affect treatment outcomes.
Collapse
Affiliation(s)
- Esra Sümer
- grid.11220.300000 0001 2253 9056Institute of Biomedical Engineering, Boğaziçi University, Kandilli Campus, Rasathane Cad, 34684 Üsküdar, Istanbul Turkey
| | - Ece Tek
- grid.411117.30000 0004 0369 7552Department of Radiation Oncology, School of Medicine, Acıbadem Mehmet Ali Aydınlar University, Istanbul, Turkey
| | - O. Artunç Türe
- grid.411117.30000 0004 0369 7552Department of Radiation Oncology, School of Medicine, Acıbadem Mehmet Ali Aydınlar University, Istanbul, Turkey
| | - Meriç Şengöz
- grid.411117.30000 0004 0369 7552Department of Neurosurgery, School of Medicine, Acıbadem Mehmet Ali Aydınlar University, Istanbul, Turkey
| | - Alp Dinçer
- grid.411117.30000 0004 0369 7552Department of Radiology, Acıbadem Mehmet Ali Aydınlar University, Istanbul, Turkey
| | - Alpay Özcan
- grid.11220.300000 0001 2253 9056Department of Electrical and Electronics Engineering, Boğaziçi University, Istanbul, Turkey
| | - M. Necmettin Pamir
- grid.411117.30000 0004 0369 7552Department of Neurosurgery, School of Medicine, Acıbadem Mehmet Ali Aydınlar University, Istanbul, Turkey
| | - Koray Özduman
- grid.411117.30000 0004 0369 7552Department of Neurosurgery, School of Medicine, Acıbadem Mehmet Ali Aydınlar University, Istanbul, Turkey
| | - Esin Ozturk-Isik
- grid.11220.300000 0001 2253 9056Institute of Biomedical Engineering, Boğaziçi University, Kandilli Campus, Rasathane Cad, 34684 Üsküdar, Istanbul Turkey
| |
Collapse
|
4
|
Jayaprakash S, Pendse A, Deshpande S. Significance of Dosimetric Parameters in Patients Undergoing Gamma Knife Radiosurgery for Vestibular Schwannoma. J Med Phys 2022; 47:206-211. [PMID: 36212199 PMCID: PMC9543002 DOI: 10.4103/jmp.jmp_5_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2022] [Revised: 03/16/2022] [Accepted: 04/06/2022] [Indexed: 11/15/2022] Open
Abstract
Vestibular schwannoma (VS) is a benign, encapsulated, and slow-growing tumor of the myelin-forming cells of the 8th cranial nerve. Gamma Knife radiosurgery (GKRS) has become a widely accepted primary treatment modality for small- to medium-sized VSs. In the case of VS, highly conformal, precisely focused radiation is delivered to the acoustic tumor in a single session under the direct supervision of a radiosurgery team
Collapse
|
5
|
Cesme DH, Alkan A, Sari L, Kaya A, Yurtsever I, Alkan G, Seyithanoglu MH, Hatiboglu MA. The Effectiveness of Diffusion Tensor Imaging in Determining Radiological Response after Radiosurgery in Patients with Vestibular Schwannoma. Curr Med Imaging 2021; 17:602-607. [PMID: 33504315 DOI: 10.2174/1573405617666210127160848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 11/09/2020] [Accepted: 11/27/2020] [Indexed: 11/22/2022]
Abstract
BACKGROUND The effectiveness of Diffusion Tensor Imaging (DTI) in demonstrating functional changes in the tumor in determining the response to treatment after radiosurgery in patients with vestibular schwannoma (VS) is not clear yet. OBJECTIVE The study aimed to determine the change in total tumor volume (TTV) in terms of radiological response in patients who had VS and were treated with radiosurgery and investigated the relationship between the TTV, follow-up times and DTI parameters. METHODS Thirty-one patients were assessed using DTI and MRI. TTV, apparent diffusion coefficient (ADC), and fractional anisotropy (FA) were calculated. Patients were divided into three groups: those who responded to the treatment (group 1) (n=11), those who did not (group 0) (n=9) and those who remained stable (group 2) (n=11). RESULTS The mean duration of follow-up was 28.81±14 months. ADC values increased in patients with VS after radiosurgery (p=0.004). There was no statistical difference in the FA values. A significant reduction in TTV after radiosurgery was detected in group 1 (p=0.003). ADC values increased significantly after radiosurgery in group 2 (p=0.04). Although there were no significant differences, ADC values after radiosurgery increased in group 1 and group 0. CONCLUSIONS ADC values continuously increase due to radiation damage in the period before the tumor volume shrinks after radiosurgery. We think that it is not appropriate to diagnose inadequate treatment or progression only when TTV is evaluated in terms of response to treatment in the early period after radiosurgery.
Collapse
Affiliation(s)
- Dilek Hacer Cesme
- Department of Radiology, Faculty of Medicine, Bezmialem Vakif University, Istanbul, Turkey
| | - Alpay Alkan
- Department of Radiology, Faculty of Medicine, Bezmialem Vakif University, Istanbul, Turkey
| | - Lutfullah Sari
- Department of Radiology, Faculty of Medicine, Bezmialem Vakif University, Istanbul, Turkey
| | - Ahmet Kaya
- Department of Radiology, Faculty of Medicine, Bezmialem Vakif University, Istanbul, Turkey
| | - Ismail Yurtsever
- Department of Radiology, Faculty of Medicine, Bezmialem Vakif University, Istanbul, Turkey
| | - Gokberk Alkan
- Department of Otorhinolaryngology Abdurrahman Yurtaslan Oncology Training and Research Hospital, Ankara, Turkey
| | | | - Mustafa Aziz Hatiboglu
- Department of Neurosurgery, Faculty of Medicine, Bezmialem Vakif University, Istanbul, Turkey
| |
Collapse
|
6
|
Cesme DH, Alkan A, Gultekin MA, Sari L, Alkan G, Kaya A, Mayadagli A, Akdur K, Uysal O, Hatiboglu MA. Diffusion Tensor Imaging Features of the Auditory Pathways in Patients With Vestibular Schwannoma After Gamma Knife Radiosurgery. Cureus 2021; 13:e14143. [PMID: 33927945 PMCID: PMC8075324 DOI: 10.7759/cureus.14143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Objective In this study, we aimed to investigate whether there is any change in diffusion tensor imaging (DTI) parameters in ipsilateral and contralateral auditory pathways after Gamma Knife radiosurgery (GKR) in patients with vestibular schwannoma (VS) and the relationship between radiosurgery variables. Methods Sixty-six patients were evaluated with MRI and DTI before and after GKR. The apparent diffusion coefficient (ADC) and fractional anisotropy (FA) were measured from the bilateral lateral lemniscus (LL), inferior colliculus (IC), medial geniculate body (MGB), and Heschl's gyrus (HG). Results There was no significant difference in ADC and FA values obtained from bilateral LL, IC, and MGB before and after radiosurgery. However, there was a significant difference between pretreatment and post-radiosurgery contralateral HG ADC values. The ADC values obtained from the contralateral HG and IC positively correlated with the duration after radiosurgery. As the duration after radiosurgery increases, the difference between the ADC values obtained from ipsilateral and contralateral HG also increases. Conclusion The high ADC values in the contralateral HG after radiosurgery may indicate microstructural alterations such as demyelination and axonal loss. Radiation exposure doses to the brainstem and cochlea are the most important factors that can cause microstructural damage to the auditory pathways. When planning radiosurgery, extreme care should be taken to prevent the harmful effects of radiation on the auditory pathways.
Collapse
Affiliation(s)
- Dilek H Cesme
- Department of Radiology, Faculty of Medicine, Bezmialem Vakif University, Istanbul, TUR
| | - Alpay Alkan
- Department of Radiology, Faculty of Medicine, Bezmialem Vakif University, Istanbul, TUR
| | - Mehmet Ali Gultekin
- Department of Radiology, Faculty of Medicine, Bezmialem Vakif University, Istanbul, TUR
| | - Lutfullah Sari
- Department of Radiology, Faculty of Medicine, Bezmialem Vakif University, Istanbul, TUR
| | - Gokberk Alkan
- Otorhinolaryngology, Abdurrahman Yurtaslan Oncology Training and Research Hospital, Ankara, TUR
| | - Ahmet Kaya
- Department of Radiology, Faculty of Medicine, Bezmialem Vakif University, Istanbul, TUR
| | - Alpaslan Mayadagli
- Radiation Oncology, Faculty of Medicine, Bezmialem Vakif University, Istanbul, TUR
| | - Kerime Akdur
- Radiation Oncology, Faculty of Medicine, Bezmialem Vakif University, Istanbul, TUR
| | - Omer Uysal
- Biostatistics, Faculty of Medicine, Bezmialem Vakif University, Istanbul, TUR
| | - Mustafa A Hatiboglu
- Neurosurgery, Faculty of Medicine, Bezmialem Vakif University, Istanbul, TUR
| |
Collapse
|