1
|
Huo Y, Xie R, Chen X, Li S, Zou H, Liu Y, Wang Y. Comparison of a Scheimpflug imaging with other screening indices in diagnosing keratoconus and keratoconus suspect. Sci Rep 2024; 14:23187. [PMID: 39369097 PMCID: PMC11455890 DOI: 10.1038/s41598-024-74497-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2024] [Accepted: 09/26/2024] [Indexed: 10/07/2024] Open
Abstract
Keratoconus (KC) is an irreversible blinding eye disease; therefore, early screening of KC suspects (KCS) is crucial for protecting patients' quality of life. Scheimpflug imaging is a commonly used screening device in clinical practice. We aimed to evaluate the diagnostic ability of a Scheimpflug imaging device (Scansys) for KC and KCS and compared it with other Scheimpflug-based devices (Pentacam and Corvis ST). This prospective case-control study included 107 normal eyes, 72 KCS, and 57 KC. Scansys screening index Keratoconus probability (KCP) showed excellent performance in diagnosing KC at a cutoff value of 16.4 (area under the receiver operating characteristic [AUROC] = 1.000), with 100% sensitivity and 98.11% specificity. KCP had a better KCS diagnostic ability at a cutoff value of 8.9 (AUROC = 0.813) than Corvis biomechanical index (CBI, AUROC = 0.764), reaching 67.61% sensitivity and 85.85% specificity. Pentacam screening index Belin/Ambrósio enhanced ectasia display deviation (BAD-D) showed the best performance with 92.96% sensitivity and 89.62% specificity at a cutoff value of 1.525 (AUROC = 0.970) in diagnosing KCS. Scansys provides accurate KCP parameters in diagnosing KC; however, the efficiency of diagnosing KCS should be further optimized.
Collapse
Affiliation(s)
- Yan Huo
- School of Medicine, Nankai University, Tianjin, China
| | - Ruisi Xie
- School of Medicine, Nankai University, Tianjin, China
| | - Xuan Chen
- School of Medicine, Nankai University, Tianjin, China
| | | | - Haohan Zou
- Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital, Nankai University Affiliated Eye Hospital, Tianjin, China
- Nankai Eye Institute, Nankai University, No. 4, Gansu Road, Heping District, Tianjin, 300020, China
| | - Yutong Liu
- School of Medicine, Nankai University, Tianjin, China
| | - Yan Wang
- School of Medicine, Nankai University, Tianjin, China.
- Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital, Nankai University Affiliated Eye Hospital, Tianjin, China.
- Nankai Eye Institute, Nankai University, No. 4, Gansu Road, Heping District, Tianjin, 300020, China.
| |
Collapse
|
2
|
Lwowski C, Krüger D, Kohnen T. Repeatability and agreement of two ocular biometers with single and dual Scheimpflug cameras in keratoconus eyes. Graefes Arch Clin Exp Ophthalmol 2024:10.1007/s00417-024-06511-z. [PMID: 39046518 DOI: 10.1007/s00417-024-06511-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 05/07/2024] [Accepted: 05/08/2024] [Indexed: 07/25/2024] Open
Abstract
BACKGROUND To evaluate the repeatability and agreement of two different ocular biometers and Scheimpflug devices in keratoconus eyes. METHODS This prospective, comparative trial took place at the University hospital, Goethe University, Frankfurt am Main, Germany. We included eyes with keratoconus, one eye per patient, randomly selected. Measurements were taken with Galilei G6 (Ziemer, Switzerland) and Pentacam AXL (Oculus, Germany), three consecutive measurements each. Repeatability and agreement were evaluated for simulated keratometry (simK), astigmatism (simA), maximum keratometry (KMax) and its axis, total keratometry (TCP), axial length (AL), anterior chamber depth (ACD), and thinnest pachymetry (TCT). RESULTS Both devices showed an excellent repeatability with intra class correlation (ICC) of > 0.97 for all parameters. The 95% limits of repeatability (LoR95%) and agreement (LoA95%) were narrow for all parameters. The Galilei G6 had a narrower LoAR95% for TCT (2.1 μm vs. 4.6 μm), but a wider LoR95% for KMax (0.52D vs. 1.18D). No relevant difference was found for the other parameters. Agreement between the devices was good to moderate, especially for simK and TCP. CONCLUSIONS Both devices show excellent repeatability with narrow LoR95% and high ICC for all parameters. The only relevant difference was found for KMax and TCT in favor of Pentacam AXL and Galilei G6, respectively. Agreement was good to moderate, and most parameters should not be considered interchangeable.
Collapse
Affiliation(s)
- Christoph Lwowski
- Department of Ophthalmology, Goethe-University, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany
| | - Daniel Krüger
- Department of Ophthalmology, Goethe-University, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany
| | - Thomas Kohnen
- Department of Ophthalmology, Goethe-University, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany.
| |
Collapse
|
3
|
Gustafsson I, Olafsdottir T, Neumann O, Johansson P, Bizios D, Ivarsen A, Hjortdal JØ. Early findings in a randomised controlled trial on crosslinking protocols using isoosmolar and hypoosmolar riboflavin for the treatment of progressive keratoconus. Acta Ophthalmol 2024. [PMID: 38970233 DOI: 10.1111/aos.16736] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Accepted: 06/22/2024] [Indexed: 07/08/2024]
Abstract
PURPOSE To present baseline characteristics and to present the perioperative corneal thickness during corneal crosslinking (CXL) treatment for progressive keratoconus and to describe how the addition of sterile water (SW) efficaciously can maintain the corneal thickness. The treatment efficacy will be evaluated when the 1-year follow-up is complete. METHODS A randomised clinical study using epithelium-off CXL with continuous UVA irradiation (9 mW/cm2) and two kinds of riboflavin solutions: (i) isoosmolar dextran-based riboflavin (n = 27) and (ii) hypoosmolar dextran-free riboflavin (n = 27). INCLUSION CRITERIA progressive keratoconus with an increase in maximum keratometry value (Kmax) of 1.0 dioptre (12 months) or 0.5 dioptres (6 months). Corneae thinner than 400 μm were also included. OUTCOME PARAMETERS Perioperative corneal thickness and the effect of adding SW. RESULTS Seventy-four per cent of the patients in the isoosmolar group and 15% in the hypoosmolar group required the addition of SW, which effectively maintained a corneal thickness of 400 μm in all cases during CXL. The addition of SW was primarily needed during the irradiation procedure and not the preoperative soaking period. CONCLUSIONS Especially during the CXL irradiation phase, isoosmolar riboflavin causes a significant dehydrating effect leading to corneal thinning during CXL. The customised addition of SW is efficacious in maintaining the corneal thickness during CXL and could increase the safety of the procedure.
Collapse
Affiliation(s)
- Ingemar Gustafsson
- Department of Ophthalmology, Skåne University Hospital, Malmö, Sweden
- Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Thorbjörg Olafsdottir
- Department of Ophthalmology, Skåne University Hospital, Malmö, Sweden
- Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Olof Neumann
- Department of Ophthalmology, Skåne University Hospital, Malmö, Sweden
- Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Per Johansson
- Department of Ophthalmology, Skåne University Hospital, Malmö, Sweden
- Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Dimitrios Bizios
- Department of Ophthalmology, Skåne University Hospital, Malmö, Sweden
- Department of Clinical Sciences, Lund University, Malmö, Sweden
| | - Anders Ivarsen
- Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark
| | - Jesper Ø Hjortdal
- Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
4
|
Eguileor BDL, Zorrozúa BS, Ecenarro JE. The HUC progression score: A new method for determining KERATOCONUS progression. Eur J Ophthalmol 2024; 34:973-979. [PMID: 38632934 PMCID: PMC11295412 DOI: 10.1177/11206721241247587] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Accepted: 03/31/2024] [Indexed: 04/19/2024]
Abstract
PURPOSE To establish new criteria for the progression of keratoconus, taking into account a Pentacam HR (high resolution) tomographeŕs repeatability limit. METHODS This is a retrospective observational study, including 224 eyes in 154 patients diagnosed with keratoconus and patients treated with crosslinking, with a follow-up of at least one year, in which the new progression score of the Cruces University Hospital for keratoconus progression was analyzed. This score takes into account: maximum keratometry, thinnest corneal thickness, maximum posterior elevation, vertical coma and RMS of high order aberrations, all based on the tomographer repeatability limit. The effectiveness or not of crosslinking was determined. RESULTS The Receiver Operating Characteristics (ROC) curves obtained in our validation met the criteria by being far from the reference diagonal. Moreover, young patients are more likely to have keratoconus that progresses, and the percentage of patients that showed progression was 14.3% of the eyes studied, with the most advanced keratoconus showing the least progression. Taking into account the new progression score of the Cruces Hospital, we would have indicated crosslinking in 2 eyes only and we observed that none progressed one year after treatment. CONCLUSIONS The the new progression score of the Cruces University Hospital is a method based on the real repeatability limit for keratoconic eyes. Moreover, it is easy to interpret and can be implemented with Pentacam software. It provides a numerical value that evaluates both the anterior and posterior surfaces of the cornea and corneal aberrations in the evolution of keratoconus.
Collapse
Affiliation(s)
- Beatriz de Luis Eguileor
- Deparment of Ophthalmology, BioCruces Bizkaia Health Research Institute, Cruces University Hospital, Barakaldo, Spain
| | - Borja Santos Zorrozúa
- Scientific Coordination Unit, Biocruces Bizkaia Health Research Institute, Cruces University Hospital, Osakidetza, Bilbao, Basque Country, Spain
| | - Jaime Etxebarria Ecenarro
- Deparment of Ophthalmology, BioCruces Bizkaia Health Research Institute, Cruces University Hospital, Barakaldo, Spain
| |
Collapse
|
5
|
Bordais J, Cassagne M, Touboul D, Saunier V, Butterworth J, Malecaze F, Soler V, Fournié P. Conventional Epithelial-Off Corneal Crosslinking in Patients With Progressive Keratoconus: 10-Year Outcomes. Cornea 2024; 43:874-882. [PMID: 38537067 PMCID: PMC11142646 DOI: 10.1097/ico.0000000000003532] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2023] [Revised: 11/23/2023] [Accepted: 01/29/2024] [Indexed: 06/02/2024]
Abstract
PURPOSE Corneal crosslinking (CXL) is the standard treatment of progressive keratoconus (KC). We evaluated the safety and 10-year outcomes of conventional "epithelial-off" CXL for progressive KC for the first time in a cohort in France. METHODS We conducted a retrospective review of patients undergoing conventional CXL (Dresden protocol) in our tertiary ophthalmology department from 2006 to 2011 with 10-year follow-up. The primary outcome was change in preoperative versus postoperative keratometry measured by maximum keratometry (Kmax), steep keratometry (K2), flat keratometry (K1), mean keratometry (Km), and topographic cylinder. Secondary outcomes were changes in visual and refractive outcomes. We report postoperative complications and adverse events. RESULTS Eighty-nine eyes from 76 patients (67% male patients, mean age 22.7 ± 7.6 years) were included. Mean Kmax (-2.31 ± 2.98 diopters (D); P < 0.00001), K2 (-2.07 ± 3.15 D; P < 0.00001), K1 (-1.00 ± 2.29 D; P = 0.00008), Km (-1.53 ± 2.47 D; P < 0.00001), and topographic cylinder (-1.15 ± 2.53 D; P = 0.00004) significantly decreased 10 years after CXL compared with preoperative baseline. Significant decreases were still observed between 5 and 10 years after for mean Kmax, mean K2, mean K1, and mean Km. Mean distance best spectacle-corrected visual acuity and mean manifest refraction spherical equivalent were significantly improved after 10 years versus before CXL. The 10-year rate of repeat CXL was n = 3/76 patients (4%) (all younger than 18 years at first CXL) and of loss of >3 lines in best spectacle-corrected visual acuity was n = 1/76 patients (1%). CONCLUSIONS Progressive KC was effectively stabilized with a prolonged flattening and maintenance of functional vision improvements after 10 years. Repeat CXL was rare and only required among younger patients.
Collapse
Affiliation(s)
- Jérémy Bordais
- Ophthalmology Department, Pierre-Paul Riquet Hospital, Toulouse University Hospital, Toulouse, France
| | - Myriam Cassagne
- Ophthalmology Department, Pierre-Paul Riquet Hospital, Toulouse University Hospital, Toulouse, France
- University of Toulouse III, Toulouse, France; and
| | - David Touboul
- Ophthalmology Department, Anterior Segment Unit, Bordeaux University Hospital, Bordeaux, France
| | - Valentine Saunier
- Ophthalmology Department, Anterior Segment Unit, Bordeaux University Hospital, Bordeaux, France
| | - Jacqueline Butterworth
- Ophthalmology Department, Pierre-Paul Riquet Hospital, Toulouse University Hospital, Toulouse, France
| | - François Malecaze
- Ophthalmology Department, Pierre-Paul Riquet Hospital, Toulouse University Hospital, Toulouse, France
- University of Toulouse III, Toulouse, France; and
| | - Vincent Soler
- Ophthalmology Department, Pierre-Paul Riquet Hospital, Toulouse University Hospital, Toulouse, France
- University of Toulouse III, Toulouse, France; and
| | - Pierre Fournié
- Ophthalmology Department, Pierre-Paul Riquet Hospital, Toulouse University Hospital, Toulouse, France
- University of Toulouse III, Toulouse, France; and
| |
Collapse
|
6
|
Bograd A, Himmel I, Pfister IB, Seiler TG, Frueh BE, Tappeiner C. Comparison of corneal measurements in keratoconus eyes with two swept-source-optical coherence tomography devices and a Scheimpflug device. Graefes Arch Clin Exp Ophthalmol 2024; 262:891-901. [PMID: 37688609 DOI: 10.1007/s00417-023-06219-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 07/25/2023] [Accepted: 08/26/2023] [Indexed: 09/11/2023] Open
Abstract
PURPOSE To assess the feasibility and reliability of biometric measurements taken with the Eyestar 900 device in keratoconus eyes in comparison with those taken with the Pentacam HR and IOLMaster 700. METHODS Seventy-five eyes of 75 patients with keratoconus were included. The central corneal thickness (CCT), thinnest point of corneal thickness (TCT), axial length (AL), flat (K1) and steep (K2) anterior and posterior (Kp1, Kp2) keratometry, maximal keratometry (KMax) and anterior chamber depth (ACD) were compared between the Eyestar 900, Pentacam HR and IOLMaster 700. Reliability parameters such as the coefficient of variation (CoV) and intraclass correlation coefficient (ICC) were calculated. Pearson's r was determined to assess the correlation between devices. RESULTS A high repeatability (CoV < 1%) and intraclass correlation (ICC > 0.9) was found for all devices, led by AL, TCT, K1 and K2 (CoV 0.01-0.36%; ICC 0.994-1.00). The largest correlation between devices was found for AL (Eyestar vs. IOLMaster, r = 1.0), K1 (Eyestar vs. IOLMaster, r = 0.997) and ACD (Eyestar vs. IOLMaster, r = 0.995; Pentacam vs. IOLMaster, r = 0.987; Eyestar vs. Pentacam, r = 0.983), but there were significant differences in measured values between devices (p < 0.001), whereas the correlation was only slightly lower (r = 0.947 to 0.994) for KMax, CCT, TCT, K2, Kp1 and Kp2. CONCLUSION Keratometric and axial length measurements with the Eyestar 900 were feasible and revealed a high repeatability and a good correlation to the other devices in eyes with keratoconus.
Collapse
Affiliation(s)
- Alexandra Bograd
- Department of Ophthalmology, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland.
- Berner Augenklinik, Bern, Switzerland.
- Department of Ophthalmology, Pallas Klinik, Olten, Switzerland.
| | - Isabelle Himmel
- Department of Ophthalmology, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland
| | | | - Theo G Seiler
- Department of Ophthalmology, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland
- Institut für Refraktive und Ophthalmo-Chirurgie (IROC), Zurich, Switzerland
- Klinik für Augenheilkunde, Universitätsklinikum Düsseldorf, Düsseldorf, Germany
| | - Beatrice E Frueh
- Department of Ophthalmology, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland
| | - Christoph Tappeiner
- Department of Ophthalmology, Pallas Klinik, Olten, Switzerland
- Department of Ophthalmology, University Hospital Essen, University Duisburg-Essen, Essen, Germany
- Department of Ophthalmology, San Raffaele Scientific Institute, University Vita-Salute, Milan, Italy
- Medical Faculty, University of Bern, Bern, Switzerland
| |
Collapse
|
7
|
Ning R, Wang Y, Xu Z, Gustafsson I, Li J, Savini G, Schiano-Lomoriello D, Xiao Y, Chen A, Wang X, Zhou X, Huang J. Assessing progression limits in different grades of keratoconus from a novel perspective: precision of measurements of the corneal epithelium. EYE AND VISION (LONDON, ENGLAND) 2024; 11:1. [PMID: 38163895 PMCID: PMC10759576 DOI: 10.1186/s40662-023-00368-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Accepted: 12/05/2023] [Indexed: 01/03/2024]
Abstract
BACKGROUND To assess repeatability and reproducibility of corneal epithelium thickness (ET) measured by a spectral-domain optical coherence tomographer (SD-OCT)/Placido topographer (MS-39, CSO, Florence, Italy) in keratoconus (KC) population at different stages, as well as to determine the progression limits for evaluating KC progression. METHODS A total of 149 eyes were enrolled in this study, with 29 eyes in the forme fruste keratoconus (FFKC) group, 34 eyes in the mild KC group, 40 eyes in the moderate KC group, and 46 eyes in the severe KC group. Employing the within-subject standard deviation (Sw), test-retest variability (TRT), coefficient of variation (CoV), and intraclass correlation coefficient (ICC) to evaluate intraoperator repeatability and interoperator reproducibility. RESULTS The repeatability and reproducibility of MS-39 in patients with KC were acceptable, according to ICC values ranging from 0.732 to 0.954. However, patients with more severe KC and progressive peripheralization of the measurement points had higher TRTs but a thinning trend. The current study tended to set the cut-off values of mild KC, moderate KC, and severe KC to 4.9 µm, 5.2 µm, and 7.4 µm for thinnest epithelium thickness (TET). When differences between follow-ups are higher than those values, progression of the disease is possible. As for center epithelium thickness (CET), cut-off values for mild KC, moderate KC, and severe KC should be 2.8 µm, 4.4 µm, and 5.3 µm. This might be useful in the follow-up and diagnosis of keratoconus. CONCLUSIONS This study demonstrated that the precision of MS-39 was reduced in measuring more severe KC patients and more peripheral corneal points. In determining disease progression, values should be differentiated between disease-related real changes and measurement inaccuracies. Due to the large difference in ET measured by MS-39 between various stages of disease progression, it is necessary to accurately grade KC patients to avoid errors in KC clinical decision-making.
Collapse
Affiliation(s)
- Rui Ning
- Eye Institute and Department of Ophthalmology and Vision Science, Institute for Medical and Engineering Innovation, Eye and ENT Hospital, Fudan University, N No.19 Baoqing Road, Xuhui District, Shanghai, 200031, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
| | - Yiran Wang
- Eye Institute and Department of Ophthalmology and Vision Science, Institute for Medical and Engineering Innovation, Eye and ENT Hospital, Fudan University, N No.19 Baoqing Road, Xuhui District, Shanghai, 200031, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
| | - Zhenyu Xu
- Eye Institute and Department of Ophthalmology and Vision Science, Institute for Medical and Engineering Innovation, Eye and ENT Hospital, Fudan University, N No.19 Baoqing Road, Xuhui District, Shanghai, 200031, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
| | - Ingemar Gustafsson
- Department of Clinical Sciences, Ophthalmology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Jiawei Li
- Eye Institute and Department of Ophthalmology and Vision Science, Institute for Medical and Engineering Innovation, Eye and ENT Hospital, Fudan University, N No.19 Baoqing Road, Xuhui District, Shanghai, 200031, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
| | | | | | - Yichen Xiao
- Eye Institute and Department of Ophthalmology and Vision Science, Institute for Medical and Engineering Innovation, Eye and ENT Hospital, Fudan University, N No.19 Baoqing Road, Xuhui District, Shanghai, 200031, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
| | - Aodong Chen
- Eye Institute and Department of Ophthalmology and Vision Science, Institute for Medical and Engineering Innovation, Eye and ENT Hospital, Fudan University, N No.19 Baoqing Road, Xuhui District, Shanghai, 200031, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
| | - Xiaoying Wang
- Eye Institute and Department of Ophthalmology and Vision Science, Institute for Medical and Engineering Innovation, Eye and ENT Hospital, Fudan University, N No.19 Baoqing Road, Xuhui District, Shanghai, 200031, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
| | - Xingtao Zhou
- Eye Institute and Department of Ophthalmology and Vision Science, Institute for Medical and Engineering Innovation, Eye and ENT Hospital, Fudan University, N No.19 Baoqing Road, Xuhui District, Shanghai, 200031, China.
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China.
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.
| | - Jinhai Huang
- Eye Institute and Department of Ophthalmology and Vision Science, Institute for Medical and Engineering Innovation, Eye and ENT Hospital, Fudan University, N No.19 Baoqing Road, Xuhui District, Shanghai, 200031, China.
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China.
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.
| |
Collapse
|
8
|
Koppen C, Jiménez-García M, Kreps EO, Ní Dhubhghaill S, Rozema JJ. Definitions for Keratoconus Progression and Their Impact on Clinical Practice. Eye Contact Lens 2024; 50:1-9. [PMID: 37816249 DOI: 10.1097/icl.0000000000001038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/29/2023] [Indexed: 10/12/2023]
Abstract
PURPOSE There is currently no consensus on which keratoconus need cross-linking nor on how to establish progression. This study assessed the performance of diverse progression criteria and compared them with our clinical knowledge of keratoconus evolution. METHODS This was a retrospective, longitudinal, observational study. Habitual progression criteria, based on (combinations of) keratometry (K MAX ), front astigmatism (A F ), pachymetry (P MIN ), or ABCD progression display, from 906 keratoconus patients were analyzed. For each criterion and cutoff, we calculated %eyes flagged progressive at some point (R PROG ), individual consistency C IND (%examinations after progression detection still considered progressive), and population consistency C POP (% eyes with CIND >66%). Finally, other monotonic and consistent variables, such as front steep keratometry (K 2F ), mean radius of the back surface (R mB ), and the like, were evaluated for the overall sample and subgroups. RESULTS Using a single criterion (e.g., ∆K MAX >1D) led to high values of R PROG . When combining two, (K MAX and A F ) led to worse C POP and higher variability than (K MAX and P MIN ); alternative criteria such as (K 2F and R mB ) obtained the best C POP and the lowest variability ( P <0.0001). ABC, as defined by its authors, obtained R PROG of 74.2%. Using wider 95% confidence intervals (95% CIs) and requiring two parameters over 95CI reduced R PROG to 27.9%. CONCLUSION Previous clinical studies suggest that 20% to 30% of keratoconus cases are progressive. This clinical R PROG value should be considered when defining KC progression to avoid overtreatment. Using combinations of variables or wider margins for ABC brings R PROG closer to these clinical observations while obtaining better population consistency than current definitions.
Collapse
Affiliation(s)
- Carina Koppen
- Department of Ophthalmology (C.K., M.J.-G., S.N.D., J.J.R.), Antwerp University Hospital (UZA), Edegem, Belgium; Department of Medicine and Health Sciences (C.K., M.J.-G., S.N.D., J.J.R.), University of Antwerp, Antwerp, Belgium; Department of Ophthalmology (E.O.K.), Ghent University Hospital (UZA), Edegem, Belgium; and Department of Medicine and Health Sciences (E.O.K.), University of Ghent, Ghent, Belgium
| | | | | | | | | |
Collapse
|
9
|
Wadhwa H, Gokul A, Li Y, Cheung I, Angelo L, McGhee CNJ, Ziaei M. Repeatability of Scheimpflug based corneal tomography parameters in advanced keratoconus with thin corneas. Eye (Lond) 2023; 37:3429-3434. [PMID: 37076688 PMCID: PMC10630456 DOI: 10.1038/s41433-023-02528-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2022] [Revised: 03/25/2023] [Accepted: 04/05/2023] [Indexed: 04/21/2023] Open
Abstract
OBJECTIVE To determine the repeatability limits of corneal tomography parameters in patients with advanced and moderately thin keratoconic corneas to assist in planning thickness-based procedural interventions. METHODS Prospective, single-centre, repeatability study. Three tomography scans using the Pentacam AXL were obtained from patients with keratoconus with thinnest corneal thickness (TCT) ≦400 µm (sub-400 group) and compared to those with TCT = 450-500 µm (450-plus group). Eyes with previous crosslinking, intraocular surgery, or acute corneal hydrops were excluded. Eyes were age and gender-matched. The within-subject standard deviations for flat keratometry (K1), steep keratometry (K2), maximal keratometry (Kmax), astigmatism and TCT were used to calculate respective repeatability limits (r). Intra-class correlation coefficients (ICC) were also analysed. RESULTS The sub-400 group comprised 114 eyes from 114 participants, and the 450-plus group comprised 114 eyes from 114 participants. In the sub-400 group, TCT was amongst the least repeatable parameters (33.92 µm; ICC 0.96), compared with the 450-plus group (14.32 µm; ICC 0.99, p < 0.01). In the sub-400 group, K1 and K2 of the anterior surface were the most repeatable parameters (r 3.79 and 3.22 respectively; ICC 0.97 and 0.98 respectively) compared with the 450-plus group (r 1.17 and 0.92 respectively; and ICC 0.98 and 0.99 respectively, p < 0.01). CONCLUSIONS The repeatability of corneal tomography measurements is significantly reduced in sub-400 keratoconic corneas when compared to 450-plus corneas. Repeatability limits should be carefully considered when surgical interventions are planned for such patients.
Collapse
Affiliation(s)
- Himanshu Wadhwa
- Department of Ophthalmology, University of Auckland, Auckland, New Zealand
| | - Akilesh Gokul
- Department of Ophthalmology, University of Auckland, Auckland, New Zealand
| | - Ye Li
- Department of Ophthalmology, University of Auckland, Auckland, New Zealand
| | - Isabella Cheung
- Department of Ophthalmology, University of Auckland, Auckland, New Zealand
| | - Lize Angelo
- Department of Ophthalmology, University of Auckland, Auckland, New Zealand
| | - Charles N J McGhee
- Department of Ophthalmology, University of Auckland, Auckland, New Zealand
| | - Mohammed Ziaei
- Department of Ophthalmology, University of Auckland, Auckland, New Zealand.
| |
Collapse
|
10
|
Gustafsson I, Ivarsen A, Hjortdal J. Early findings in a prospective randomised study on three cross-linking treatment protocols: interruption of the iontophoresis treatment protocol. BMJ Open Ophthalmol 2023; 8:e001406. [PMID: 37739426 PMCID: PMC10533787 DOI: 10.1136/bmjophth-2023-001406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Accepted: 09/03/2023] [Indexed: 09/24/2023] Open
Abstract
PURPOSE To present the outcome of the interrupted iontophoresis-assisted treatment arm in an ongoing randomised clinical trial (NCT04427956). METHODS A randomised clinical study of corneal cross-linking (CXL) using continuous UV-A irradiation at a rate of 9 mW/cm2 and three different types of riboflavin and riboflavin delivery mode: (1) iso-osmolar dextran-based riboflavin (epithelium-off), (2) hypo-osmolar dextran-free riboflavin (epithelium-off) and (3) iontophoresis-assisted delivery of riboflavin (epithelium-on) for the treatment of progressive keratoconus. Inclusion criteria were an increase in the maximum keratometry value (Kmax) of 1.0 dioptre over 12 months or 0.5 dioptre over 6 months. The primary outcome in evaluating treatment efficacy was Kmax. Recently presented stratified detection limits were used post hoc to confirm the enrolment of patients with truly progressive keratoconus and in the assessment of the need for re-CXL. RESULTS Thirteen patients had been randomised to iontophoresis-assisted CXL when the treatment arm was interrupted; two patients dropped out. Of the remaining 11 patients, 7 were deemed as having truly progressive disease according to the more recent stratified detection limits. The disease continued to progress in three patients according to the original definition (increase in Kmax≥1 D), necessitating re-CXL with epithelium-off CXL. This progression was confirmed by post hoc analysis using the stratified detection limits for progression. CONCLUSIONS The iontophoresis-assisted CXL protocol failed to halt further disease progression in 27% of the patients. The failure rate increased to 38% when considering only the patients deemed to have truly progressive disease using the stratified detection limits.
Collapse
Affiliation(s)
- Ingemar Gustafsson
- Ophthalmology, Lund University, Lund, Sweden
- Ophthalmology, Skåne University Hospital Lund, Lund, Sweden
| | - Anders Ivarsen
- Ophthalmology, Aarhus University Hospital, Aarhus N, Denmark
| | - Jesper Hjortdal
- Ophthalmology, Aarhus University Hospital, Aarhus N, Denmark
| |
Collapse
|
11
|
Ortiz-Toquero S, Fuente C, Auladell C, Arnalich-Montiel F. Influence of Keratoconus Severity on Detecting True Progression with Scheimpflug Imaging and Anterior Segment Optical Coherence Tomography. Life (Basel) 2023; 13:1474. [PMID: 37511849 PMCID: PMC10382025 DOI: 10.3390/life13071474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 06/17/2023] [Accepted: 06/28/2023] [Indexed: 07/30/2023] Open
Abstract
To determine consistent change over time in keratoconus disease, it is necessary to establish progression cut-off values based on intersession variability of the device used to monitor the cornea. The aim of this study was to analyze the accuracy of corneal parameters using Scheimpflug tomography and anterior segment optical coherence tomography in healthy and keratoconic eyes of varying severity to determine the cut-off values that indicate real progression. Three repeated measurements of each cornea of healthy (20 eyes) and keratoconic eyes (mild = 16, moderate = 25 and severe = 20) were recorded using Pentacam and Casia SS-1000 devices, which were repeated 2-3 weeks later. K1, K2, maximal anterior and posterior keratometry, and corneal thickness at the thinnest location (TCT) were collected. The accuracy was excellent with both devices; however, the Casia device presented better repeatability and reproducibility in all parameters in all groups compared to the Pentacam. The cut-off of the Pentacam and Casia in the mild stage were lower (K1 = 0.50 and 0.37 D; K2 = 0.51 and 0.37 D; Kmax-A = 1.24 and 0.65 D; Kmax-P = 0.38 and 0.17 D; TCT = 19.64 and 11.19 µm) than that of the severe stage (K1 = 1.09 and 0.88 D; K2 = 1.41 and 0.87 D; Kmax-A = 2.74 and 2.15 D; Kmax-P = 0.82 and 0.22 D; TCT = 28.68 and 14.83 µm). These results show that the greater the keratoconus severity, the greater the change that must occur for it to be considered real.
Collapse
Affiliation(s)
- Sara Ortiz-Toquero
- Department of Ophthalmology, Ramón y Cajal University Hospital, Carretera de Colmenar Viejo Km 9, 100, 28034 Madrid, Spain
- Optometry Research Group, IOBA-Eye Institute, Department of Theoretical Physics, Atomic and Optics, University of Valladolid, 47011 Valladolid, Spain
| | - Carlota Fuente
- Department of Ophthalmology, Ramón y Cajal University Hospital, Carretera de Colmenar Viejo Km 9, 100, 28034 Madrid, Spain
| | - Clara Auladell
- Department of Ophthalmology, Ramón y Cajal University Hospital, Carretera de Colmenar Viejo Km 9, 100, 28034 Madrid, Spain
| | - Francisco Arnalich-Montiel
- Department of Ophthalmology, Ramón y Cajal University Hospital, Carretera de Colmenar Viejo Km 9, 100, 28034 Madrid, Spain
| |
Collapse
|
12
|
Gustafsson I, Bizios D, Ivarsen A, Hjortdal JØ. Patient experience and repeatability of measurements made with the Pentacam HR in patients with keratoconus. BMC Ophthalmol 2023; 23:201. [PMID: 37150816 PMCID: PMC10165742 DOI: 10.1186/s12886-023-02930-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Accepted: 04/20/2023] [Indexed: 05/09/2023] Open
Abstract
BACKGROUND To investigate whether the repeatability of measurements with the Pentacam HR in patients with keratoconus is improved by patients gaining more experience of the measurement situation. Such an improvement could enhance the accuracy with which progressive keratoconus can be detected. METHODS Four replicate measurements were performed on Day 0 and on Day 3. Parameters commonly used in the diagnosis of progressive keratoconus were included in the analysis, namely the flattest central keratometry value (K1), the steepest central keratometry value (K2), the maximum keratometry value (Kmax), and the parameters A, B and C from the Belin ABCD Progression Display. In addition, quality parameters used by the Pentacam HR to assess the quality of the measurements were included, namely the analysed area (front + back), 3D (front + back), XY, Z, and eye movements. RESULTS Neither the diagnostic parameters nor the quality parameters showed any statistically significant improvement on Day 3 compared to Day 0. The quality parameter "eye movements" deteriorated significantly with increasing Kmax. CONCLUSION Gaining experience of the measurement situation did not increase the accuracy of the measurements. Further investigations should be performed to determine whether the increasing number of eye movements with increasing disease severity has a negative effect on the repeatability of the measurements.
Collapse
Affiliation(s)
- Ingemar Gustafsson
- Department of Ophthalmology, Skåne University Hospital, Department of Clinical Sciences, Lund University, Lund, Sweden.
| | - Dimitrios Bizios
- Department of Ophthalmology, Skåne University Hospital, Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Anders Ivarsen
- Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark
| | - Jesper Ø Hjortdal
- Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
13
|
Gustafsson I, Bizios D, Ivarsen A, Hjortdal JØ. The intra- and inter-day repeatability of corneal densitometry measurements in subjects with keratoconus and in healthy controls. Sci Rep 2023; 13:5566. [PMID: 37019974 PMCID: PMC10076276 DOI: 10.1038/s41598-023-32822-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2023] [Accepted: 04/03/2023] [Indexed: 04/07/2023] Open
Abstract
The healthy cornea is transparent, however, disease can affect its structure, rendering it more or less opaque. The ability to assess the clarity of the cornea objectively could thus be of considerable interest for keratoconus patients. It has previously been suggested that densitometry can be used to diagnose early keratoconus, and that the values of densitometry variables increase with increasing disease severity, indicating that densitometry could also be used to assess progressive keratoconus. Previous studies have only assessed the repeatability of corneal densitometry measurements on the same day, which does not reflect the clinical setting in which changes are evaluated over time. We have therefore evaluated the inter-day repeatability of densitometry measurements in both patients with keratoconus and healthy controls. Measurements in the middle layer of the 2-6 mm zone of the cornea showed the best repeatability. Although an objective measure of the corneal transparency could be interesting, the generally poor repeatability of densitometry measurements limits their use. The repeatability of corneal clarity measurements could be improved by using other approaches such as optical coherence tomography, but this remains to be investigated. Such improvements would allow the more widespread use of corneal densitometry in clinical practice.
Collapse
Affiliation(s)
- Ingemar Gustafsson
- Department of Clinical Sciences, Ophthalmology, Lund University, Lund, Sweden.
- Department of Ophthalmology, Skåne University Hospital, Kioskgatan 1 , 221 85, Lund, Sweden.
| | - Dimitrios Bizios
- Department of Clinical Sciences, Ophthalmology, Lund University, Lund, Sweden
| | - Anders Ivarsen
- Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark
| | - Jesper Ø Hjortdal
- Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
14
|
Gustafsson I, Vicente A, Bergström A, Stenevi U, Ivarsen A, Hjortdal JØ. Current clinical practice in corneal crosslinking for treatment of progressive keratoconus in four Nordic countries. Acta Ophthalmol 2023; 101:109-116. [PMID: 35811357 PMCID: PMC10084360 DOI: 10.1111/aos.15213] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 05/24/2022] [Accepted: 06/26/2022] [Indexed: 01/25/2023]
Abstract
PURPOSE To evaluate clinical practice in the diagnosis and treatment of progressive keratoconus with corneal crosslinking (CXL) in four Nordic countries. METHODS A questionnaire was sent to all centres at which keratoconus patients are evaluated and CXL is performed in Sweden, Denmark, Norway and Iceland. Nineteen of 20 centres participated. RESULTS CXL is performed approximately 1300 times per year in these four Nordic countries with a population of around 21.7 million (2019). In most cases, progression is evaluated using the Pentacam HR, and the maximum keratometry reading (Kmax ) is considered the most important parameter. The most frequently used treatment protocol in Scandinavia is the 9 mW/cm2 epi-off protocol, using hydroxylpropyl methylcellulose riboflavin (HPMC-riboflavin). The participants deemed the following areas to be in most need of improvement: adaptation of the CXL protocol to individual patients (5/19), the development of effective epi-on treatment protocols (4/19), optimal performance of CXL in thin corneas (4/19), improvement of the definition of progression (2/19), and diagnosis of the need for re-treatment (2/19). CONCLUSIONS We concluded that the diagnosis of progressive keratoconus and the diagnostic equipment used are similar. Treatment strategies are also similar but are suitably different to provide an interesting basis for the comparison of treatment outcomes. The high degree of participation in this survey indicates the possibility of future scientific collaboration on CXL focusing on the areas deemed to need improvement. It would also be of interest to evaluate the possibility of creating a Nordic CXL Registry. The high number of CXL treatments performed ensures sufficient statistical power to solve many questions. Such a registry could be an important contribution to evidence-based care and would allow for longitudinal evaluation.
Collapse
Affiliation(s)
- Ingemar Gustafsson
- Department of Clinical Sciences, Department of Ophthalmology, Lund University, Skåne University Hospital, Lund, Sweden
| | - André Vicente
- Department of Clinical Sciences, Department of Ophthalmology, Lund University, Skåne University Hospital, Lund, Sweden
| | - Anders Bergström
- Department of Clinical Sciences, Department of Ophthalmology, Lund University, Skåne University Hospital, Lund, Sweden
| | - Ulf Stenevi
- Department of Ophthalmology, Sahgrenska University Hospital, Mölndal, Sweden
| | - Anders Ivarsen
- Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark
| | | |
Collapse
|
15
|
Toprak I, Kilic D. Current clinical approach to pediatric keratoconus patients. EXPERT REVIEW OF OPHTHALMOLOGY 2022. [DOI: 10.1080/17469899.2022.2085557] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Affiliation(s)
- Ibrahim Toprak
- Faculty of Medicine, Department of Ophthalmology, Pamukkale University, Denizli, Turkey
| | - Deniz Kilic
- Department of Ophthalmology, Kayseri City Training and Research Hospital, Health Science University, Kayseri, Turkey
| |
Collapse
|
16
|
Seiler TG, Mueller M, Mendes Baiao T. Repeatability and Comparison of Corneal Tomography in Mild to Severe Keratoconus Between the Anterior Segment OCT MS-39 and Pentacam HR. J Refract Surg 2022; 38:250-255. [PMID: 35412926 DOI: 10.3928/1081597x-20220114-02] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To detect keratoconus progression, accuracy of tomographic measurements is crucial. The impoved axial resolution of optical coherence tomography (OCT) compared to Scheimpflug photography serves as the motivation to investigate and compare the repeatability of the anterior segment OCT MS-39 (CSO) to Pentacam HR (Oculus Optikgeräte GmbH) in patients with keratoconus. METHODS One hundred twenty-three eyes of 123 patients with keratoconus were enrolled and subdivided in four groups by maximum keratometry (Kmax): Kmax < 48.00 diopters (D), Kmax of 48.00 to 53.01 D, Kmax of 53.00 to 58.00 D, and Kmax > 58.00 D. Three consecutive measurements per eye were acquired with the MS-39 and compared to the Pentacam HR. Kmax, thinnest pachymetry, anterior asphericity, and posterior elevation data were compared. Within-subject standard deviation (Sw), coefficient of variation (CoV), test-retest repeatability (TRT), and the intra-class correlation (ICC) were calculated and evaluated. Bland-Altman plots were also analyzed. RESULTS The Pentacam HR measures significantly higher Kmax values than the MS-39, with a more pronounced difference for severe cases of keratoconus (0.57 D for all cases; 1.88 D for cases with Kmax > 58.00 D). Thinnest pachymetry was approximately 5 µm thinner when measured by the Pentacam HR than the MS-39, independently of keratoconus stage. A further progressed keratoconus stage was significantly associated with increased measurement errors and resulted in worse repeatability (Kmax < 48.00 D: Sw = 0.18 D, TRT = 0.50 D, CoV = 0.39%, ICC = 0.989; Kmax > 58.00 D: Sw = 0.53 D, TRT = 1.48 D, CoV = 0.90%, ICC = 0.984). The behavior was similar for other tomographic parameters. CONCLUSIONS The Pentacam HR and the MS-39 have an overall good agreement for keratoconus; however, the Pentacam HR measures steeper and thinner than the MS-39. The association between the magnitude of topographic and tomographic parameters and their measurement errors suggests that the diagnosis of keratoconus disease progression should be based on the stage and the test-retest repeatability rather than on a fixed value (eg, 1.00 D). [J Refract Surg. 2022;38(4):250-255.].
Collapse
|
17
|
Borgardts K, Menzel-Severing J, Geerling G, Seiler TG. [Treatment indications for corneal crosslinking and clinical results of new corneal crosslinking techniques]. Ophthalmologe 2022; 119:350-357. [PMID: 35147774 DOI: 10.1007/s00347-022-01579-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/10/2022] [Indexed: 10/19/2022]
Abstract
BACKGROUND Corneal crosslinking (CXL) is used in keratoconus to strengthen and stabilize the cornea and to prevent further progression with subsequent visual loss and the possible need for keratoplasty. Correct treatment indications is crucial in this context. Since the introduction of the initial Dresden protocol, other modified CXL protocols have been proposed to optimize treatment success. OBJECTIVE The relevant parameters for treatment indications are explained and the clinical results of new CXL protocols are presented. METHODS The currently valid criteria with respect to the indications for CXL in keratoconus, PubMed search for relevant publications and own experiences with different CXL protocols are presented. RESULTS The reproducibility of topographic parameters depends on the stage of the keratoconus. Accelerated CXL as well as transepithelial CXL with a hyperoxic environment show comparable efficiency with shorter surgery time and possibly lower complication rates. Customized CXL with an individualized UV irradiation profile provides improved results with faster epithelial healing. Lower UV energy doses enable CXL to be conducted in eyes with minimal stromal pachymetry of less than 400 µm before irradiation. The combination of CXL with photorefractive keratectomy (PRK) provides visual acuity improvements but also increases the risk of visual loss. CONCLUSION Current indication rules for CXL neglect the reduced reproducability of topographic and tomographic measurements in keratoconus. The latest CXL protocols presented here provide a safe alternative with similar and/or better efficacy compared to standard CXL. The combination of CXL with PRK offers an option for visual rehabilitation in patients with contact lens intolerance.
Collapse
Affiliation(s)
- Klara Borgardts
- Klinik für Augenheilkunde, Universitätsklinikum Düsseldorf, Moorenstr. 5, 40225, Düsseldorf, Deutschland
| | - Johannes Menzel-Severing
- Klinik für Augenheilkunde, Universitätsklinikum Düsseldorf, Moorenstr. 5, 40225, Düsseldorf, Deutschland
| | - Gerd Geerling
- Klinik für Augenheilkunde, Universitätsklinikum Düsseldorf, Moorenstr. 5, 40225, Düsseldorf, Deutschland
| | - Theo G Seiler
- Klinik für Augenheilkunde, Universitätsklinikum Düsseldorf, Moorenstr. 5, 40225, Düsseldorf, Deutschland. .,Institut für Refraktive und Ophthalmo-Chirurgie (IROC), Stockerstr. 37, 8002, Zürich, Schweiz. .,Klinik für Augenheilkunde, Universitätsspital Bern, Inselspital Bern, 3010, Bern, Schweiz.
| |
Collapse
|
18
|
Vinciguerra R, Legrottaglie EF, Tredici C, Mazzotta C, Rosetta P, Vinciguerra P. Transepithelial Iontophoresis-Assisted Cross Linking for Progressive Keratoconus: Up to 7 Years of Follow Up. J Clin Med 2022; 11:jcm11030678. [PMID: 35160126 PMCID: PMC8836535 DOI: 10.3390/jcm11030678] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Revised: 01/20/2022] [Accepted: 01/26/2022] [Indexed: 02/07/2023] Open
Abstract
Purpose: To report long-term clinical results of transepithelial cross-linking with iontophoresis (I-CXL) for progressive keratoconus (KC). Methods: Nineteen eyes of 19 patients treated with I-CXL for progressive keratoconus were included in this prospective clinical study. Preoperatively and in all available follow ups (6, 12, 24, 36, 48, 60, 72 and 84 months), the following parameters were measured. Corrected distance visual acuity (CDVA), spherical equivalent and cylinder refraction, corneal topography and aberrometry (Costruzione Strumenti Oftalmici (C.S.O.), Florence, Italy), Scheimpflug tomography (OCULUS Optikgeräte GmbH; Wetzlar, Germany). Definition of progression after I-CXL was 2/3 of the following criteria: increase of “A” value, increase of “B” value, decrease of minimal thickness evaluated with the ABCD progression display above 95% confidence interval for post-CXL population when compared to the scan 12 months post-op. Results: The mean follow-up time of included patients was 63 months (range 12 to 84 months, 5 patients reached 84 months). The general linear model showed no significant change over time in CDVA, Maximum Keratometry, Thinnest point, and A, B, C values of the Belin Progression Display (p > 0.05). Conversely, comatic and high order aberrations decreased significantly over time (both p =< 0.001). Five cases (26.31%) showed significant progression after a mean of 55 months (range 36–72) of follow up. Conclusion: Our study shows the ability of I-CXL to slow down KC progression in the majority of included patients, improving high order and comatic aberrations. A 26% progression rate was reported.
Collapse
Affiliation(s)
- Riccardo Vinciguerra
- Humanitas San Pio X Hospital, 20100 Milan, Italy
- The School of Engineering, University of Liverpool, Liverpool L69 3BX, UK
- Correspondence: ; Tel.: +39-0255211388
| | | | - Costanza Tredici
- Humanitas Clinical and Research Center—IRCCS, Via Manzoni 56, 20089 Rozzano, MI, Italy
| | - Cosimo Mazzotta
- Ophthalmology Unit, Department of Medicine, Surgery and Neurosciences, Post Graduate Ophthalmology School, University of Siena, 53100 Siena, Italy
- Ophthalmology Operative Unit, Usl Toscana Sudest, Alta Val d’Elsa Hospital, Campostaggia, 53100 Siena, Italy
- Casentino Hospital, 52100 Bibbiena, AR, Italy
- Siena Crosslinking Center, Monteriggioni, 53100 Siena, Italy
| | | | - Paolo Vinciguerra
- Humanitas Clinical and Research Center—IRCCS, Via Manzoni 56, 20089 Rozzano, MI, Italy
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20090 Pieve Emanuele, MI, Italy
| |
Collapse
|
19
|
Tabl A, Elsayed M, Tabl M. Correlation between changes in corneal asphericity and progression of keratoconus in children. JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY 2022. [DOI: 10.4103/ejos.ejos_11_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
20
|
Ng SM, Hawkins BS, Kuo IC. Transepithelial Versus Epithelium-Off Corneal Crosslinking for Progressive Keratoconus: Findings From a Cochrane Systematic Review. Am J Ophthalmol 2021; 229:274-287. [PMID: 34048801 PMCID: PMC8599612 DOI: 10.1016/j.ajo.2021.05.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Revised: 05/11/2021] [Accepted: 05/15/2021] [Indexed: 11/29/2022]
Abstract
PURPOSE The purpose of this study was to summarize key findings from a systematic review of the effectiveness and safety of transepithelial corneal crosslinking (CXL) compared with epithelium-off CXL for progressive keratoconus. DESIGN Cochrane systematic review. METHODS We included in our review only randomized controlled trials (RCTs) in which transepithelial and epithelium-off CXL had been compared among participants with progressive keratoconus. The primary outcome was keratoconus stabilization based on post-operative maximum keratometry (Kmax). We adhered to Cochrane methods for trial selection, data extraction, risk of bias evaluation, and data synthesis. RESULTS Thirteen RCTs with 567 participants (661 eyes) were included; 11 studies compared non-iontophoresis-assisted transepithelial with epithelium-off CXL. Keratoconus stabilization was described as an outcome in 2 studies. The estimated difference in Kmax means (ie, the "mean difference," MD) from meta-analysis of 177 eyes in 5 RCTs indicated that there were no differences between intervention groups in Kmax at 12 months or later (MD: 0.99 diopter [D]; 95% confidence interval: -0.11 to 2.09). Meta-analysis of keratometry and visual acuity outcomes at 12 months or longer after surgery from 2 studies that had compared transepithelial CXL using iontophoresis provided no conclusive evidence of an advantage over epithelium-off CXL. CONCLUSIONS Lack of precision due to small sample sizes, indeterminate risk of bias due to inadequate reporting, and inconsistency in how outcomes were measured and reported among studies make it difficult to state with confidence whether transepithelial CXL confers an advantage over epithelium-off CXL for patients with progressive keratoconus with respect to stabilization of keratoconus, visual acuity, or patient-reported outcomes based on available data.
Collapse
Affiliation(s)
- Sueko M Ng
- From the Department of Ophthalmology (S.M.N.), School of Medicine, University of Colorado, Aurora, Colorado, USA
| | - Barbara S Hawkins
- and the Department of Ophthalmology (B.S.H., I.C.K.), Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Irene C Kuo
- and the Department of Ophthalmology (B.S.H., I.C.K.), Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
| |
Collapse
|
21
|
An inter-day assessment of the ABC parameters in the evaluation of progressive keratoconus. Sci Rep 2021; 11:16037. [PMID: 34362986 PMCID: PMC8346622 DOI: 10.1038/s41598-021-95503-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Accepted: 07/26/2021] [Indexed: 12/05/2022] Open
Abstract
The progression of keratoconus is commonly determined by comparing the results of corneal tomographic measurements on different occasions. However, investigations on the repeatability of measurements are commonly performed within the same day, thus not taking the inter-day variation into account. The effect of keratoconus disease severity on the measurement error is also seldom considered. In this post hoc investigation, the parameters A, B and C in the Belin ABCD Progression Display were evaluated in relation to disease severity in intra-day and inter-day measurements. Four consecutive measurements were performed on 61 patients with keratoconus on the same day (intra-day). In another cohort, four consecutive measurements were obtained and then repeated 3 days later in 25 patients with keratoconus and 25 healthy controls (inter-day). The results suggest that the diagnosis of disease progression would benefit from inter-day measurements, and the stratification of the parameters A and C according to disease severity. It is also recommended that tomographic systems such as the Pentacam HR be modified to allow the comparison of both single measurements and the mean of replicate measurements of the parameters used in the assessment of progression of keratoconus.
Collapse
|
22
|
Evaluating keratoconus progression prior to crosslinking: maximum keratometry vs the ABCD grading system. J Cataract Refract Surg 2021; 47:33-39. [PMID: 33181627 DOI: 10.1097/j.jcrs.0000000000000475] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Accepted: 07/18/2020] [Indexed: 01/03/2023]
Abstract
PURPOSE To evaluate the correlation between changes in maximum keratometry (Kmax) and ABC values from the ABCD Progression Display (Pentacam) in progressive keratoconus (KC) and to evaluate whether the ABC changes were able to detect progression earlier than Kmax. SETTING Humanitas Clinical and Research Center, Rozzano, Milan, Italy. DESIGN Retrospective study. METHODS Kmax, ABC values, and thinnest point (ThCT) were recorded at the day of corneal crosslinking (CXL) (T0) and previous follow-up (T-1). In patients without earlier progression in Kmax, follow-up examination (T-2) was used to determine whether any of the ABC parameters reached statistical significance for progression. RESULTS Seventy-six eyes of 63 patients scheduled for CXL with documented progression (Kmax increase of >1.00 diopter) were included. There was a significant, albeit moderate, correlation between the change in Kmax between T0 and T-1 and the change in both A (ρ = 0.391) and B values (ρ = 0.339). There was no significant correlation between the change in Kmax between T0 and T-1 and the change in either C or ThCT. In patients with T-2 examinations, 16 (51.6%) of 31 patients showed a statistically significant change on the ABCD progression display that was not detected with Kmax. CONCLUSIONS This study showed a significant, but moderate, correlation between the change in Kmax and the change in A and B values in progressive KC. Moreover, more than half of the cases showed documented progression earlier with the ABCD progression display than that detected by standard Kmax changes. This study suggests possible changes in progression criteria to allow for earlier intervention.
Collapse
|
23
|
Abstract
Keratoconus is morphologically associated with increasing deformation, thinning and scarring of the cornea. This functionally leads to refractive changes and visual deterioration. In the early stages there are often no clear clinical signs in the slit-lamp examination; however, confirming the diagnosis as early as possible is important in order to provide patients with an appropriate treatment. For the early diagnosis of keratoconus, various diagnostic devices have been introduced in recent years and decades. These include keratometry with reflection-based or elevation-based systems and optical coherence tomography. High-frequency ultrasound microscopy and corneal biomechanics can also be used to establish the diagnosis of keratoconus by the measurement of other parameters. The necessity and the available possibilities for early diagnosis of keratoconus are presented in more detail in this article.
Collapse
|
24
|
The Interday Repeatability of Parameters for the Assessment of Progressive Disease in Subjects With Less Advanced Keratoconus. Am J Ophthalmol 2021; 225:38-46. [PMID: 33422466 DOI: 10.1016/j.ajo.2020.12.028] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 12/28/2020] [Accepted: 12/28/2020] [Indexed: 11/23/2022]
Abstract
PURPOSE To evaluate the interday repeatability in the measurement of parameters used for the detection of progression of keratoconus by prediction limits (PL) for single measurements, and the repeatability coefficient (RC) for the mean of replicate measurements. DESIGN Prospective reliability analysis for cases and control eyes. METHODS Twenty-five eyes in 25 subjects with KC and 25 eyes in 25 healthy controls were included. Four consecutive measurements were made, 3 days apart, with a Pentacam HR tomographic instrument (denoted the Pentacam) and a Nidek ARK 560-A auto-keratometer (denoted the keratometer). Main outcome measures were the intra- and interday RC of parameters used in the detection of progression of keratoconus. RESULTS The most repeatable parameter obtained with the Pentacam was the curvature power of the central flat meridian (K1, 0.44 D [RC], -0.55 to 0.60 diopter [D] [PL]), followed by the central steep meridian (K2, 0.72 D [RC], -0.90 to 0.94 D [PL]). The interday repeatability of K1 and K2 was similar when using the keratometer (K1, 0.32 D [RC], -0.66 to 0.57 D [PL], K2, 0.93 D [RC], -1.36 to 1.08 D [PL]). The interday repeatability of the curvature power of the steepest point (Kmax, 0.84 D [RC], -0.90 to 1.11 D [PL]) would benefit from being stratified: RC = 0.44 D and PL = -0.49 to 0.67 D for Kmax < 49.0 D, and RC = 1.08 D and PL = -1.19 to 1.42 D for Kmax ≥ 49.0 D. CONCLUSIONS The interday repeatability of measurements, single or replicate, in subjects with keratoconus should be considered when diagnosing progressive disease. K1 exhibited the best intraday repeatability. Kmax benefits from being stratified according to disease severity.
Collapse
|
25
|
Gilevska F, Biscevic A, Popovic Suic S, Bohac M, Patel S. Are changes in visual acuity and astigmatism after corneal cross-linking (CXL) in keratoconus predictable? Graefes Arch Clin Exp Ophthalmol 2021; 259:2259-2268. [PMID: 33885984 DOI: 10.1007/s00417-021-05173-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Revised: 03/05/2021] [Accepted: 03/22/2021] [Indexed: 10/21/2022] Open
Abstract
PURPOSE To evaluate changes in corrected distance visual acuity (CDVA), ratio of anterior and posterior corneal radii over the thinnest region of the cornea (ARC/PRC), and astigmatism after cross-linking (CXL) in keratoconus. METHODS Subjective refraction and ARC/PRC (using Pentacam™) were monitored over 1 year in (I) keratoconus treated with routine CXL (n = 53), (II) relatively stable keratoconus (n = 23), and (III) age/gender matched controls (n = 24). RESULTS CDVA (median, mode, interquartile range) improved significantly in group I, compared with groups II and III (p < 0.05), from 0.45 (0.60, 0.20-0.63) to 0.80 (0.95, 0.60-0.95); change in CDVA was associated with preop CDVA (p < 0.01 at all times postop). ARC/PRC (mean ± sd, 95% CI) changed from 1.362 (± 0.048, 1.347-1.377) to 1.425 (± 0.073, 1.401-1.449). CDVA and ARC/PRC remained stable in II and III. Significant relationships were revealed between logCDVA and ARC/PRC in I and II (at 12 months, I rs = - 0.464, II rs - 0.449) and logCDVA at postop(y), log CDVA at preop(x1), and ARC/PRC at preop(x2) in I (at 12 months, y = 0.356x1 - 1.312x2 + 1.806, r21 = 0.494, r22 = 0.203). Astigmatic power (mean ± sd, 95% CI) improved from - 3.10DC (± 1.52, - 3.55 to - 2.66) to - 2.53DC (± 1.24, - 2.90 to - 2.17) in I, and worsened from - 1.27DC (± 1.32, - 1.81 to - 0.73) to - 1.61DC (± 1.28, - 2.13 to - 1.09) in II. Vector analysis revealed in group I (a) the power of the surgically induced astigmatism (SIA) was linked to astigmatic power at preop and (b) the difference between the axis of astigmatism at preop(ø) and the axis of the SIA was linked to ø. CONCLUSION CXL improved CDVA, increased the ARC/PRC ratio, and modified the association between CDVA and ARC/PRC. The change in CDVA was linked to preop CDVA and ARC/PRC values. The association between SIA and preop astigmatism implies there is not a simple cause and effect relationship with CXL.
Collapse
Affiliation(s)
- Fanka Gilevska
- Eye Clinic Sistina Oftalmologija, Skupi 5A, Skopje, Republic of North Macedonia.
| | | | | | - Maja Bohac
- Specialty Eye Hospital "Svjetlost", Zagreb, Croatia.,School of Medicine, University of Rijeka, Rijeka, Croatia
| | - Sudi Patel
- Specialty Eye Hospital "Svjetlost", Zagreb, Croatia
| |
Collapse
|