1
|
Chan CHH, Passmore MR, Tronstad O, Seale H, Bouquet M, White N, Teruya J, Hogan A, Platts D, Chan W, Dashwood AM, McGiffin DC, Maiorana AJ, Hayward CS, Simmonds MJ, Tansley GD, Suen JY, Fraser JF, Meyns B, Fresiello L, Jacobs S. The Impact of Acute Exercise on Hemostasis and Angiogenesis Mediators in Patients With Continuous-Flow Left Ventricular Assist Devices: A Prospective Observational Pilot Study. ASAIO J 2024:00002480-990000000-00501. [PMID: 38833540 DOI: 10.1097/mat.0000000000002246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/06/2024] Open
Abstract
Impaired primary hemostasis and dysregulated angiogenesis, known as a two-hit hypothesis, are associated with gastrointestinal (GI) bleeding in patients with continuous-flow left ventricular assist devices (CF-LVADs). Exercise is known to influence hemostasis and angiogenesis in healthy individuals; however, little is known about the effect in patients with CF-LVADs. The objective of this prospective observational study was to determine whether acute exercise modulates two-hit hypothesis mediators associated with GI bleeding in patients with a CF-LVAD. Twenty-two patients with CF-LVADs performed acute exercise either on a cycle ergometer for approximately 10 minutes or on a treadmill for 30 minutes. Blood samples were taken pre- and post-exercise to analyze hemostatic and angiogenic biomarkers. Acute exercise resulted in an increased platelet count (p < 0.00001) and platelet function (induced by adenosine diphosphate, p = 0.0087; TRAP-6, p = 0.0005; ristocetin, p = 0.0009). Additionally, high-molecular-weight vWF multimers (p < 0.00001), vWF collagen-binding activity (p = 0.0012), factor VIII (p = 0.034), angiopoietin-1 (p = 0.0026), and vascular endothelial growth factor (p = 0.0041) all increased after acute exercise. This pilot work demonstrates that acute exercise modulated two-hit hypothesis mediators associated with GI bleeding in patients with CF-LVADs.
Collapse
Affiliation(s)
- Chris H H Chan
- From the Critical Care Research Group, The Prince Charles Hospital, Brisbane, Australia
- School of Engineering and Built Environment, Griffith University, Gold Coast, Australia
- Faculty of Medicine, University of Queensland, Brisbane, Australia
- Innovative Device & Engineering Applications Laboratory, Texas Heart Institute, Houston, Texas
| | - Margaret R Passmore
- From the Critical Care Research Group, The Prince Charles Hospital, Brisbane, Australia
- Faculty of Medicine, University of Queensland, Brisbane, Australia
| | - Oystein Tronstad
- From the Critical Care Research Group, The Prince Charles Hospital, Brisbane, Australia
- Physiotherapy Department, The Prince Charles Hospital, Brisbane, Australia
| | - Helen Seale
- Physiotherapy Department, The Prince Charles Hospital, Brisbane, Australia
| | - Mahe Bouquet
- From the Critical Care Research Group, The Prince Charles Hospital, Brisbane, Australia
- Faculty of Medicine, University of Queensland, Brisbane, Australia
| | - Nicole White
- From the Critical Care Research Group, The Prince Charles Hospital, Brisbane, Australia
- School of Public Health and Social Work, Queensland University of Technology, Brisbane, Australia
| | - Jun Teruya
- Departments of Pathology & Immunology, Pediatrics, and Medicine, Baylor College of Medicine, Houston, Texas
| | - Airlie Hogan
- Department of Cardiology, The Prince Charles Hospital, Brisbane, Australia
| | - David Platts
- Department of Cardiology, The Prince Charles Hospital, Brisbane, Australia
| | - Wandy Chan
- Department of Cardiology, The Prince Charles Hospital, Brisbane, Australia
- Cardio-Vascular Molecular and Therapeutics Translational Research Group, University of Queensland, Brisbane, Australia
| | - Alexander M Dashwood
- Department of Cardiology, The Prince Charles Hospital, Brisbane, Australia
- Cardio-Vascular Molecular and Therapeutics Translational Research Group, University of Queensland, Brisbane, Australia
| | - David C McGiffin
- From the Critical Care Research Group, The Prince Charles Hospital, Brisbane, Australia
- Department of Cardiothoracic Surgery and Transplantation, The Alfred Hospital, Melbourne, Australia
- Department of Cardiothoracic Surgery, Monash University, Melbourne, Australia
| | - Andrew J Maiorana
- Allied Health Department, Fiona Stanley Hospital, Perth, Australia
- Curtin School of Allied Health, Curtin University, Perth, Australia
| | - Christopher S Hayward
- Heart Failure and Transplant Unit, St. Vincent's Hospital, Sydney, Australia
- Victor Chang Cardiac Research Institute, Sydney, Australia
| | - Michael J Simmonds
- Menzies Health Institute Queensland, Griffith University, Gold Coast, Australia
| | - Geoff D Tansley
- From the Critical Care Research Group, The Prince Charles Hospital, Brisbane, Australia
- School of Engineering and Built Environment, Griffith University, Gold Coast, Australia
| | - Jacky Y Suen
- From the Critical Care Research Group, The Prince Charles Hospital, Brisbane, Australia
- Faculty of Medicine, University of Queensland, Brisbane, Australia
| | - John F Fraser
- From the Critical Care Research Group, The Prince Charles Hospital, Brisbane, Australia
- Faculty of Medicine, University of Queensland, Brisbane, Australia
| | - Bart Meyns
- Department of Cardiovascular Sciences, Cardiac Surgery, Katholieke Universiteit Leuven, Leuven, Belgium; and
| | - Libera Fresiello
- Department of Cardiovascular Sciences, Cardiac Surgery, Katholieke Universiteit Leuven, Leuven, Belgium; and
- Group of Cardiovascular and Respiratory Physiology, University of Twente, Enschede, The Netherlands
| | - Steven Jacobs
- Department of Cardiovascular Sciences, Cardiac Surgery, Katholieke Universiteit Leuven, Leuven, Belgium; and
| |
Collapse
|
2
|
Kitagaki K, Aoki T, Miura H, Shimada Y, Konishi H, Tsukamoto Y, Noguchi T. Depressive symptoms, right ventricular function, and muscular strength are associated with peak oxygen uptake in patients with implantable left ventricular assist devices. Artif Organs 2024; 48:166-174. [PMID: 37921338 DOI: 10.1111/aor.14672] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 09/12/2023] [Accepted: 10/12/2023] [Indexed: 11/04/2023]
Abstract
BACKGROUND Left ventricular assist device (LVAD) implantation is among the most effective treatment options for patients with severe heart failure. Although previous studies have examined the factors related to peak oxygen uptake (peak VO2 ), they were limited by the few patients involved and their focus on medical and physical functions. Therefore, this study comprehensively examined the factors associated with peak VO2 , which is an important prognostic factor in patients with implantable LVADs. METHODS Eighty-nine patients who underwent initial LVAD implantation and were eligible for cardiopulmonary exercise testing (CPX) between May 2014 and September 2021 were included. The patients' mean age was 48 ± 12 years, and 70% were males. Based on previous studies, the cut-off was set at 12 and 14 mL/kg/min for patients taking β-blocker and those not taking β-blockers, respectively. Furthermore, factors associated with peak VO2 were examined using multivariate logistic regression analysis. RESULTS The mean time from surgery to CPX administration was 73 ± 40 days. The high group had a higher cardiac index, right ventricular stroke work index (RVSWI), and isometric knee extensor muscular strength and lower Patient Health Questionnaire-9 (PHQ-9) and B-type natriuretic peptide values than the low group. Multivariate logistic regression analysis showed that RVSWI and KEMS were positively correlated, whereas PHQ-9 was negatively associated with peak VO2 . CONCLUSION Right ventricular function, depressive symptoms, and lower limb muscular strength were associated with exercise capacity in patients with implantable LVADs.
Collapse
Affiliation(s)
- Kazufumi Kitagaki
- Faculty of Rehabilitation, Shijonawate Gakuen University, Daito, Japan
- Department of Cardiovascular Rehabilitation, National Cerebral and Cardiovascular Center, Suita, Japan
| | - Tatsuo Aoki
- Department of Cardiovascular Rehabilitation, National Cerebral and Cardiovascular Center, Suita, Japan
- Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, Suita, Japan
| | - Hiroyuki Miura
- Department of Cardiovascular Rehabilitation, National Cerebral and Cardiovascular Center, Suita, Japan
- Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, Suita, Japan
| | - Yukihiro Shimada
- Department of Cardiovascular Rehabilitation, National Cerebral and Cardiovascular Center, Suita, Japan
| | - Harumi Konishi
- Department of Nursing, National Cerebral and Cardiovascular Center, Suita, Japan
| | - Yasumasa Tsukamoto
- Department of Transplant Medicine, National Cerebral and Cardiovascular Center, Suita, Japan
| | - Teruo Noguchi
- Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, Suita, Japan
| |
Collapse
|
3
|
Schlöglhofer T, Gross C, Moscato F, Neumayer A, Kandioler E, Leithner D, Skoumal M, Laufer G, Wiedemann D, Schima H, Zimpfer D, Marko C. Exercise Performance and Quality of Life of Left Ventricular Assist Device Patients After Long-Term Outpatient Cardiac Rehabilitation. J Cardiopulm Rehabil Prev 2023; 43:346-353. [PMID: 37014949 DOI: 10.1097/hcr.0000000000000789] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/06/2023]
Abstract
PURPOSE Exercise performance and quality of life (QoL) of left ventricular assist device (LVAD) patients improve after early cardiac rehabilitation (CR). The purpose of this study was to examine the efficacy of multiprofessional long term phase 3 outpatient CR, and whether cardiopulmonary exercise testing (CPX) and 6-min walk testing (6MWT) post-LVAD implantation predict hospital readmission. METHODS This retrospective observational cohort study included 29 LVAD patients (58.6 ± 7.7 yr, female: 13.8%, body mass index: 29.4 ± 3.3 kg/m 2 ). Functional performance tests (CPX, 6MWT, sit-to-stand test), QoL, and psychological surveys (Kansas City Cardiomyopathy Questionnaire, hospital anxiety and depression scale, and Control Convictions about Disease and Health [KKG]) were performed at baseline and at the end of CR. RESULTS The CR was initiated at a median (IQR) of 159 (130-260) d after LVAD implantation for a duration of 340 (180-363) d with 46.8 ± 23.2 trainings. The 6MWT (408.4 ± 113.3 vs 455.4 ± 115.5 m, P = .003) and sit-to-stand test (16.7 ± 6.9 vs 19.0 ± 5.3 repetitions, P = .033) improved, but relative peak oxygen uptake (V˙ o2peak : 9.4 [8.2-14.4] vs 9.3 [7.8-13.4] mL/min/kg, P = .57) did not change. Using receiver operating characteristic curve analysis, baseline V˙ o2peak values were associated with readmission 1-yr after CR onset (C-statistic = 0.88) with a cutoff value of V˙ o2peak < 9.15 mL/min/kg (100% sensitivity, 78% specificity, P < .001). The Kansas City Cardiomyopathy Questionnaire self-efficacy and knowledge (+6.3 points), QoL (+5.0 points), and social limitation (+7.1 points) demonstrated clinically important changes. In addition, the hospital anxiety and depression scale showed a significant reduction in anxiety (4.6 ± 3.2 vs 2.6 ± 2.4, P = .03). CONCLUSIONS Long-term CR is safe and LVAD outpatients showed improvement of QoL, anxiety, and submaximal exercise performance. In addition, V˙ o2peak and 6MWT have prognostic value for readmission.
Collapse
Affiliation(s)
- Thomas Schlöglhofer
- Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria (Messrs Schlöglhofer and Neumayer and Drs Gross, Laufer, Wiedemann, Schima, Zimpfer, and Marko); Ludwig Boltzmann Institute for Cardiovascular Research, Vienna, Austria (Messrs Schlöglhofer and Neumayer and Drs Moscato, Schima, and Zimpfer); Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria (Mr Schlöglhofer and Drs Moscato and Schima); Austrian Cluster for Tissue Regeneration, Vienna, Austria (Dr Moscato); and Center for Outpatient Rehabilitation Vienna, Vienna, Austria (Drs Kandioler and Skoumal and Ms Leithner)
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Wernhart S, Balcer B, Rassaf T, Luedike P. Increased Dead Space Ventilation as a Contributing Factor to Persistent Exercise Limitation in Patients with a Left Ventricular Assist Device. J Clin Med 2023; 12:3658. [PMID: 37297853 PMCID: PMC10253286 DOI: 10.3390/jcm12113658] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 05/16/2023] [Accepted: 05/23/2023] [Indexed: 06/12/2023] Open
Abstract
(1) Background: The exercise capacity of patients with a left ventricular assist device (LVAD) remains limited despite mechanical support. Higher dead space ventilation (VD/VT) may be a surrogate for right ventricular to pulmonary artery uncoupling (RV-PA) during cardiopulmonary exercise testing (CPET) to explain persistent exercise limitations. (2) Methods: We investigated 197 patients with heart failure and reduced ejection fraction with (n = 89) and without (HFrEF, n = 108) LVAD. As a primary outcome NTproBNP, CPET, and echocardiographic variables were analyzed for their potential to discriminate between HFrEF and LVAD. As a secondary outcome CPET variables were evaluated for a composite of hospitalization due to worsening heart failure and overall mortality over 22 months. (3) Results: NTproBNP (OR 0.6315, 0.5037-0.7647) and RV function (OR 0.45, 0.34-0.56) discriminated between LVAD and HFrEF. The rise of endtidal CO2 (OR 4.25, 1.31-15.81) and VD/VT (OR 1.23, 1.10-1.40) were higher in LVAD patients. Group (OR 2.01, 1.07-3.85), VE/VCO2 (OR 1.04, 1.00-1.08), and ventilatory power (OR 0.74, 0.55-0.98) were best associated with rehospitalization and mortality. (4) Conclusions: LVAD patients displayed higher VD/VT compared to HFrEF. Higher VD/VT as a surrogate for RV-PA uncoupling could be another marker of persistent exercise limitations in LVAD patients.
Collapse
Affiliation(s)
- Simon Wernhart
- Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center, University Hospital Essen, University Duisburg-Essen, Hufelandstrasse 55, 45147 Essen, Germany; (B.B.); (T.R.); (P.L.)
| | | | | | | |
Collapse
|
5
|
Wernhart S, Papathanasiou M, Jakstaite A, Hoffmann J, Schmack B, Hedderich J, Ruhparwar A, Rassaf T, Luedike P. Exercise oscillatory ventilation in patients with advanced heart failure with and without left ventricular assist device. Artif Organs 2023; 47:168-179. [PMID: 36102469 DOI: 10.1111/aor.14398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Revised: 06/25/2022] [Accepted: 08/26/2022] [Indexed: 01/04/2023]
Abstract
BACKGROUND Exercise oscillatory ventilation (EOV), indicating pathological fluctuations on pulmonary arterial pressure, is associated with mortality in patients with heart failure (HF). Whether left ventricular assist device (LVAD)-induced ventricular unloading can reverse EOV and may prevent short-term rehospitalization has not been investigated. METHODS We performed a retrospective single-center in- and outpatient analysis of patients with (n = 20, LVAD) and without (n = 27, HF) circulatory support and reduced ejection fraction (EF, 22.8 ± 7.9%). The association of cardiopulmonary exercise testing (CPET) variables and 3 months-rehospitalization (3MR) as a primary outcome was analyzed. Furthermore, CPET variables were compared regarding the presence of EOV (+/-). RESULTS Lower VO2peak (11.6 ± 4.9 ml/kg/min vs. 14.4 ± 4.3 ml/kg/min, p = 0.039), lower increase of PETCO2 (CI = 0.049-1.127; p = 0.068), and higher VE/VCO2 (43.8 ± 9.5 vs. 38.3 ± 10.6; p = 0.069) were associated with 3MR. Flattening of O2 pulse (CI = 0.139-2.379; p = 0.487) had no impact on 3MR. EOV was present in 59.5% (n = 28/47) of patients, without a significant difference between LVAD and HF patients (p = 0.959). Patients with HF/EOV+ demonstrated significantly lower VO2peak compared with HF/EOV- (p = 0.039). LVAD/EOV+ displayed significantly lower EF (p = 0.004) and fewer aortic valve opening than LVAD/EOV- (p = 0.027). CONCLUSIONS Lower VO2peak , but not EOV, was associated with 3MR. EOV occurred at a similar rate in LVAD and HF patients, which may illustrate insufficient unloading during exercise in chronic LVAD therapy and may contribute to the limited exercise capacity following LVAD implantation. Simultaneous CPET and right heart catheterization studies are needed to elucidate whether EOV may serve as a non-invasive predictor of insufficient LV unloading necessitating LVAD reprograming.
Collapse
Affiliation(s)
- Simon Wernhart
- Department of Cardiology and Vascular Medicine, West German Heart- and Vascular Center, University Hospital Essen, University Duisburg-Essen, Essen, Germany
| | - Maria Papathanasiou
- Department of Cardiology and Vascular Medicine, West German Heart- and Vascular Center, University Hospital Essen, University Duisburg-Essen, Essen, Germany
| | - Aiste Jakstaite
- Department of Cardiology and Vascular Medicine, West German Heart- and Vascular Center, University Hospital Essen, University Duisburg-Essen, Essen, Germany
| | - Julia Hoffmann
- Department of Cardiology and Vascular Medicine, West German Heart- and Vascular Center, University Hospital Essen, University Duisburg-Essen, Essen, Germany
| | - Bastian Schmack
- Clinic of Thoracic and Cardiovascular Surgery, West German Heart- and Vascular Center, University Hospital Essen, University Duisburg-Essen, Essen, Germany
| | - Jürgen Hedderich
- Medistat- Biomedical Statistics, Medistat GmbH, Kronshagen, Germany
| | - Arjang Ruhparwar
- Clinic of Thoracic and Cardiovascular Surgery, West German Heart- and Vascular Center, University Hospital Essen, University Duisburg-Essen, Essen, Germany
| | - Tienush Rassaf
- Department of Cardiology and Vascular Medicine, West German Heart- and Vascular Center, University Hospital Essen, University Duisburg-Essen, Essen, Germany
| | - Peter Luedike
- Department of Cardiology and Vascular Medicine, West German Heart- and Vascular Center, University Hospital Essen, University Duisburg-Essen, Essen, Germany
| |
Collapse
|
6
|
Fresiello L, Muthiah K, Goetschalckx K, Hayward C, Rocchi M, Bezy M, Pauls JP, Meyns B, Donker DW, Zieliński K. Initial clinical validation of a hybrid in silico—in vitro cardiorespiratory simulator for comprehensive testing of mechanical circulatory support systems. Front Physiol 2022; 13:967449. [PMID: 36311247 PMCID: PMC9606213 DOI: 10.3389/fphys.2022.967449] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2022] [Accepted: 09/07/2022] [Indexed: 11/13/2022] Open
Abstract
Simulators are expected to assume a prominent role in the process of design—development and testing of cardiovascular medical devices. For this purpose, simulators should capture the complexity of human cardiorespiratory physiology in a realistic way. High fidelity simulations of pathophysiology do not only allow to test the medical device itself, but also to advance practically relevant monitoring and control features while the device acts under realistic conditions. We propose a physiologically controlled cardiorespiratory simulator developed in a mixed in silico-in vitro simulation environment. As inherent to this approach, most of the physiological model complexity is implemented in silico while the in vitro system acts as an interface to connect a medical device. As case scenarios, severe heart failure was modeled, at rest and at exercise and as medical device a left ventricular assist device (LVAD) was connected to the simulator. As initial validation, the simulator output was compared against clinical data from chronic heart failure patients supported by an LVAD, that underwent different levels of exercise tests with concomitant increase in LVAD speed. Simulations were conducted reproducing the same protocol as applied in patients, in terms of exercise intensity and related LVAD speed titration. Results show that the simulator allows to capture the principal parameters of the main adaptative cardiovascular and respiratory processes within the human body occurring from rest to exercise. The simulated functional interaction with the LVAD is comparable to the one clinically observed concerning ventricular unloading, cardiac output, and pump flow. Overall, the proposed simulation system offers a high fidelity in silico-in vitro representation of the human cardiorespiratory pathophysiology. It can be used as a test bench to comprehensively analyze the performance of physically connected medical devices simulating clinically realistic, critical scenarios, thus aiding in the future the development of physiologically responding, patient-adjustable medical devices. Further validation studies will be conducted to assess the performance of the simulator in other pathophysiological conditions.
Collapse
Affiliation(s)
- Libera Fresiello
- Cardiovascular and Respiratory Physiology, University of Twente, Enschede, Netherlands
- Department of Cardiovascular Sciences, Katholieke Universiteit Leuven, Leuven, Belgium
- *Correspondence: Libera Fresiello,
| | - Kavitha Muthiah
- Department of Cardiology, St Vincent’s Hospital, Sydney, NSW, Australia
| | - Kaatje Goetschalckx
- Department of Cardiovascular Diseases, University Hospitals Leuven, Leuven, Belgium
| | - Christopher Hayward
- Department of Cardiology, St Vincent’s Hospital, Sydney, NSW, Australia
- Victor Chang Cardiac Research Institute, Sydney, NSW, Australia
| | - Maria Rocchi
- Department of Cardiovascular Sciences, Katholieke Universiteit Leuven, Leuven, Belgium
| | - Maxime Bezy
- Department of Cardiovascular Sciences, Katholieke Universiteit Leuven, Leuven, Belgium
| | - Jo P. Pauls
- School of Engineering, Griffith University, Southport, QLD, Australia
| | - Bart Meyns
- Department of Cardiovascular Sciences, Katholieke Universiteit Leuven, Leuven, Belgium
| | - Dirk W. Donker
- Cardiovascular and Respiratory Physiology, University of Twente, Enschede, Netherlands
- Intensive Care Center, University Medical Center Utrecht, Utrecht, Netherlands
| | - Krzysztof Zieliński
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
| |
Collapse
|
7
|
LVAD as a Bridge to Remission from Advanced Heart Failure: Current Data and Opportunities for Improvement. J Clin Med 2022; 11:jcm11123542. [PMID: 35743611 PMCID: PMC9225013 DOI: 10.3390/jcm11123542] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 06/16/2022] [Accepted: 06/16/2022] [Indexed: 02/04/2023] Open
Abstract
Left ventricular assist devices (LVADs) are an established treatment modality for advanced heart failure (HF). It has been shown that through volume and pressure unloading they can lead to significant functional and structural cardiac improvement, allowing LVAD support withdrawal in a subset of patients. In the first part of this review, we discuss the historical background, current evidence on the incidence and assessment of LVAD-mediated cardiac recovery, and out-comes including quality of life after LVAD support withdrawal. In the second part, we discuss current and future opportunities to promote LVAD-mediated reverse remodeling and improve our pathophysiological understanding of HF and recovery for the benefit of the greater HF population.
Collapse
|
8
|
(Physiology of Continuous-flow Left Ventricular Assist Device Therapy. Translation of the document prepared by the Czech Society of Cardiology). COR ET VASA 2022. [DOI: 10.33678/cor.2022.040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
9
|
OUP accepted manuscript. Eur J Cardiothorac Surg 2022; 62:6526431. [DOI: 10.1093/ejcts/ezac053] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 12/14/2021] [Accepted: 01/25/2022] [Indexed: 11/12/2022] Open
|
10
|
Rosenbaum AN, Antaki JF, Behfar A, Villavicencio MA, Stulak J, Kushwaha SS. Physiology of Continuous-Flow Left Ventricular Assist Device Therapy. Compr Physiol 2021; 12:2731-2767. [PMID: 34964115 DOI: 10.1002/cphy.c210016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The expanding use of continuous-flow left ventricular assist devices (CF-LVADs) for end-stage heart failure warrants familiarity with the physiologic interaction of the device with the native circulation. Contemporary devices utilize predominantly centrifugal flow and, to a lesser extent, axial flow rotors that vary with respect to their intrinsic flow characteristics. Flow can be manipulated with adjustments to preload and afterload as in the native heart, and ascertainment of the predicted effects is provided by differential pressure-flow (H-Q) curves or loops. Valvular heart disease, especially aortic regurgitation, may significantly affect adequacy of mechanical support. In contrast, atrioventricular and ventriculoventricular timing is of less certain significance. Although beneficial effects of device therapy are typically seen due to enhanced distal perfusion, unloading of the left ventricle and atrium, and amelioration of secondary pulmonary hypertension, negative effects of CF-LVAD therapy on right ventricular filling and function, through right-sided loading and septal interaction, can make optimization challenging. Additionally, a lack of pulsatile energy provided by CF-LVAD therapy has physiologic consequences for end-organ function and may be responsible for a series of adverse effects. Rheological effects of intravascular pumps, especially shear stress exposure, result in platelet activation and hemolysis, which may result in both thrombotic and hemorrhagic consequences. Development of novel solutions for untoward device-circulatory interactions will facilitate hemodynamic support while mitigating adverse events. © 2021 American Physiological Society. Compr Physiol 12:1-37, 2021.
Collapse
Affiliation(s)
- Andrew N Rosenbaum
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, USA.,William J von Liebig Center for Transplantation and Clinical Regeneration, Mayo Clinic, Rochester, Minnesota, USA
| | - James F Antaki
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, USA
| | - Atta Behfar
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, USA.,William J von Liebig Center for Transplantation and Clinical Regeneration, Mayo Clinic, Rochester, Minnesota, USA.,VanCleve Cardiac Regenerative Medicine Program, Center for Regenerative Medicine, Mayo Clinic, Rochester, Minnesota, USA
| | | | - John Stulak
- Department of Cardiovascular Surgery, Mayo Clinic, Rochester, Minnesota, USA
| | - Sudhir S Kushwaha
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, USA.,William J von Liebig Center for Transplantation and Clinical Regeneration, Mayo Clinic, Rochester, Minnesota, USA
| |
Collapse
|
11
|
Kerrigan DJ, Cowger JA, Keteyian SJ. Exercise in patients with left ventricular devices: The interaction between the device and the patient. Prog Cardiovasc Dis 2021; 70:33-39. [PMID: 34921848 DOI: 10.1016/j.pcad.2021.12.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Accepted: 12/12/2021] [Indexed: 12/28/2022]
Abstract
Advances in the engineering of surgically implanted, durable left ventricular assist devices (LVAD) has led to improvements in the two-year survival of patients on LVAD support, which is now comparable to that of heart transplant (HT) recipients. And with the advent of magnetic levitation technology, both the survival rate and average time on LVAD support are expected to improve even further. However, despite these advances, the functional capacity of patients on LVAD support remains reduced compared to those who received a HT. A few small clinical trials have shown improvement in functional capacity with exercise training. Peak oxygen uptake improves modestly (10%-20%) with exercise training, suggesting a possible celling-effect linked to the ability of the LVAD to increase flow during exercise. This paper reviews both (a) the effect of the LVAD on the cardiorespiratory responses during a single, acute bout of exercise up to maximum and (b) the central and peripheral adaptations that occur among patients with an LVAD who undergo an exercise training regimen. We also address the tenets of the exercise prescription that are unique to patients with a durable LVAD.
Collapse
Affiliation(s)
- Dennis J Kerrigan
- Division of Cardiovascular Medicine, Henry Ford Hospital, Detroit, MI, USA.
| | - Jennifer A Cowger
- Division of Cardiovascular Medicine, Henry Ford Hospital, Detroit, MI, USA
| | - Steven J Keteyian
- Division of Cardiovascular Medicine, Henry Ford Hospital, Detroit, MI, USA
| |
Collapse
|
12
|
Abstract
PURPOSE OF REVIEW Exercise causes various dynamic changes in all body parts either in healthy subject or in heart failure (HF) patients. The present review of current knowledge about HF patients with reduced ejection fraction focuses on dynamic changes along a "metabo-hemodynamic" perspective. RECENT FINDINGS Studies on the dynamic changes occurring during exercise span many years. Thanks to the availability of advanced methods, it is nowadays possible to properly characterize respiratory, hemodynamic, and muscular function adjustments and their mismatch with the pulmonary and systemic circulations. Exercise is a dynamic event that involves several body functions. In HF patients, it is important to know at what level the limitation takes place in order to better manage these patients and to optimize therapeutic strategies.
Collapse
|
13
|
Fresiello L, Gross C, Jacobs S. Exercise physiology in left ventricular assist device patients: insights from hemodynamic simulations. Ann Cardiothorac Surg 2021; 10:339-352. [PMID: 34159115 DOI: 10.21037/acs-2020-cfmcs-23] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Left ventricular assist devices (LVADs) assure longer survival to patients, but exercise capacity is limited compared to normal values. Overall, LVAD patients show high wedge pressure and low cardiac output during maximal exercise, a phenomenon hinting at the need for increased LVAD support. Clinical studies investigating the hemodynamic benefits of an LVAD speed increase during exercise, ended in inhomogeneous and sometimes contradictory results. The native ventricle-LVAD interaction changes between rest and exercise, and this evolution is complex, multifactorial and patient-specific. The aim of this paper is to provide a comprehensive overview on the patient-LVAD interaction during exercise and to delineate possible therapeutic strategies for the future. A computational cardiorespiratory model was used to simulate the hemodynamics of peak bicycle exercise in LVAD patients. The simulator included the main cardiovascular and respiratory impairments commonly observed in LVAD patients, so as to represent an average hemodynamic response to exercise. In addition, other exercise responses were simulated, by tuning the chronotropic, inotropic and vascular functions, and implementing aortic regurgitation and stenosis in the simulator. These profiles were tested under different LVAD speeds and LVAD pressure-flow characteristics. Simulations output showed consistency with clinical data from the literature. The simulator allowed the working condition of the assisted ventricle at exercise to be investigated, clarifying the reasons behind the high wedge pressure and poor cardiac output observed in the clinics. Patients with poorer inotropic, chronotropic and vascular functions, are likely to benefit more from an LVAD speed increase during exercise. Similarly, for these patients, a flatter LVAD pressure-flow characteristic can assure better hemodynamic support under physical exertion. Overall, the study evidenced the need for a patient-specific approach on supporting exercise hemodynamics. In this frame, a complex simulator can constitute a valuable tool to define and test personalized speed control algorithms and strategies.
Collapse
Affiliation(s)
- Libera Fresiello
- Department of Cardiovascular Sciences, Cardiac Surgery, Katholieke Universiteit Leuven, Leuven, Belgium.,Institute of Clinical Physiology, National Research Council, Pisa, Italy
| | - Christoph Gross
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Steven Jacobs
- Department of Cardiovascular Sciences, Cardiac Surgery, Katholieke Universiteit Leuven, Leuven, Belgium
| |
Collapse
|
14
|
Moscato F, Gross C, Maw M, Schlöglhofer T, Granegger M, Zimpfer D, Schima H. The left ventricular assist device as a patient monitoring system. Ann Cardiothorac Surg 2021; 10:221-232. [PMID: 33842216 DOI: 10.21037/acs-2020-cfmcs-218] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Technological progress of left ventricular assist devices (LVADs) towards rotary blood pumps and the optimization of medical management contributed to the significant improvements in patient survival as well as LVAD support duration. Even though LVAD therapy is now well-established for end-stage heart failure patients, the long-term occurrence of adverse events (AE) such as bleeding, infection or stroke, still represent a relevant burden. An early detection of AE, before onset of major symptoms, can lead to further optimization of patient treatment and thus mitigate the burden of AE. Continuous patient monitoring facilitates identification of pathophysiological states and allows anticipation of AE to improve patient management. In this paper, methods, algorithms and possibilities for continuous patient monitoring based on LVAD data are reviewed. While experience with continuous LVAD monitoring is currently limited to a few centers worldwide, the pace of developments in this field is fast and we expect these technologies to have a global impact on the well-being of LVAD patients.
Collapse
Affiliation(s)
- Francesco Moscato
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.,Ludwig Boltzmann Institute for Cardiovascular Research, Vienna, Austria.,Austrian Cluster for Tissue Regeneration, Vienna, Austria
| | - Christoph Gross
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.,Ludwig Boltzmann Institute for Cardiovascular Research, Vienna, Austria
| | - Martin Maw
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.,Ludwig Boltzmann Institute for Cardiovascular Research, Vienna, Austria.,Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Thomas Schlöglhofer
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.,Ludwig Boltzmann Institute for Cardiovascular Research, Vienna, Austria.,Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Marcus Granegger
- Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Daniel Zimpfer
- Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Heinrich Schima
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.,Ludwig Boltzmann Institute for Cardiovascular Research, Vienna, Austria.,Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
15
|
Di Nora C, Guidetti F, Livi U, Antonini-Canterin F. Role of Cardiac Rehabilitation After Ventricular Assist Device Implantation. Heart Fail Clin 2021; 17:273-278. [PMID: 33673951 DOI: 10.1016/j.hfc.2021.01.008] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Patients with heart failure suffered by a complex syndrome, where the filling of the ventricle or ejection of the blood is impaired. In this setting, the exercise capacity decreases for many reasons, one of them being the insufficient oxygen transfer due to reduced cardiac output and anemia. Ventricular assist device has emerged as a durable and safe therapy for patients with end-stage heart failure. The benefits of cardiac rehabilitation in ventricular assist device patients are enormous: the first aim is to progressively reduce the physical and functional impairments of these patients, so that they will be able to resume meaningful daily activities.
Collapse
Affiliation(s)
- Concetta Di Nora
- Department of Cardiothoracic Science, Azienda Sanitaria Universitaria Integrata di Udine, Italy.
| | - Federica Guidetti
- Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland
| | - Ugolino Livi
- Department of Cardiothoracic Science, Azienda Sanitaria Universitaria Integrata di Udine, Italy
| | - Francesco Antonini-Canterin
- Cardiac Prevention and Rehabilitation Unit, Highly Specialized Rehabilitation Hospital, Motta di Livenza, Italy
| |
Collapse
|
16
|
Dridi NP, Vishram-Nielsen JKK, Gustafsson F. Exercise Tolerance in Patients Treated With a Durable Left Ventricular Assist Device: Importance of Myocardial Recovery. J Card Fail 2020; 27:486-493. [PMID: 33347995 DOI: 10.1016/j.cardfail.2020.12.005] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 11/30/2020] [Accepted: 12/08/2020] [Indexed: 12/27/2022]
Abstract
The number of patients supported with left ventricular assist devices (LVADs) is growing and support times are increasing. This has led to a greater focus on functional capacity of these patients. LVADs greatly improve heart failure symptoms, but surprisingly, improvement in peak oxygen uptake (pVO2) is small and remains decreased at approximately 50% of normal values. Inadequate increase in cardiac output during exercise is the main responsible factor for the low pVO2 in LVAD recipients. Some patients experience LV recovery during mechanical unloading and these patients have a higher pVO2. Here we review the various components determining exercise cardiac output in LVAD recipients and discuss the potential impact of cardiac recovery on these components. LV recovery may affect several components, leading to improved hemodynamics during exercise and, in turn, physical capacity in patients with advanced heart failure undergoing LVAD implantation.
Collapse
Affiliation(s)
- Nadia Paarup Dridi
- Department of Cardiology, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark
| | | | - Finn Gustafsson
- Department of Cardiology, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark; Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark.
| |
Collapse
|