1
|
Leblebicioğlu Kurtuluş İ, Kilic D, Kilic K. Dental Versus Zygomatic Implants in the Treatment of Maxillectomy: A Finite Element Analysis. J ORAL IMPLANTOL 2024; 50:220-230. [PMID: 38839068 DOI: 10.1563/aaid-joi-d-24-00008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2024]
Abstract
This study analyzed the stress distributions on zygomatic and dental implants placed in the zygomatic bone, supporting bones, and superstructures under occlusal loads after maxillary reconstruction with obturator prostheses. A total of 12 scenarios of 3-dimensional finite element models were constructed based on computerized tomography scans of a hemimaxillectomy patient. Two obturator prostheses were analyzed for each model. A total force of 600 N was applied from the palatal to buccal bones at an angle of 45°. The maximum and minimum principal stress values for bone and von Mises stress values for dental implants and prostheses were calculated. When zygomatic implants were applied to the defect area, the maximum principal stresses were similar in intensity to the other models; however, the minimum principal stress values were higher than in scenarios without zygomatic implants. In models that used zygomatic implants in the defect area, von Mises stress levels were significantly higher in zygomatic implants than in dental implants. In scenarios where the prosthesis was supported by tissue in the nondefect area, the maximum and minimum principal stress values on cortical bone were higher than in scenarios where implants were applied to defect and nondefect areas. In patients who lack an alveolar crest after maxillectomy, a custom bar-retained prosthesis placed on the dental implant should reduce stress on the zygomatic bone. The stress was higher on zygomatic implants without alveolar crest support than on dental implants.
Collapse
Affiliation(s)
| | - Duygu Kilic
- Department of Periodontology, Faculty of Dentistry, Erciyes University, Kayseri, Turkey
| | - Kerem Kilic
- Department of Prosthodontics, Faculty of Dentistry, Erciyes University, Kayseri, Turkey
| |
Collapse
|
2
|
Shash YH, El-Wakad MT, Eldosoky MAA, Dohiem MM. Finite element analysis of the effect of framework material and thickness on the biomechanical performance of 'All‑on‑Four' full-arch prosthesis. Comput Methods Biomech Biomed Engin 2024:1-16. [PMID: 38756021 DOI: 10.1080/10255842.2024.2355260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Accepted: 05/07/2024] [Indexed: 05/18/2024]
Abstract
The aim of this research was to evaluate the stress distribution in the 'All-on-Four' prosthesis and the surrounding bone, with different framework materials and thicknesses. Five frameworks (alumina, zirconia, titanium, fiberglass reinforced resin (FRR), and polyether ether ketone (PEEK)) with two thicknesses (3.5 &5.5 mm) were stimulated in this research. A vertical force of 200 N was applied on a 1 mm circular area, at the cantilever, and at the region of the incisors, simulating different mastication mechanisms. The results illustrated that the 5.5 mm framework reduced the stresses on most parts, mucosa, and bone tissues, compared to 3.5 mm.
Collapse
Affiliation(s)
- Yomna H Shash
- Department of Biomedical Engineering, Helwan University, Cairo, Egypt
| | - Mohamed T El-Wakad
- Faculty of Engineering &Technology, Future University in Egypt, Cairo, Egypt
| | | | - Mohamed M Dohiem
- Department of Prosthodontics, Zagazig University, Zagazig, Egypt
| |
Collapse
|
3
|
Zhou Z, Shi R, Wang J, Han X, Gao W, Jiao J, Qi Y, Li Y, Zhou Y, Zhao J. Finite Element Analysis of Different Carbon Fiber Reinforced Polyetheretherketone Dental Implants in Implant-supported Fixed Denture. JOURNAL OF STOMATOLOGY, ORAL AND MAXILLOFACIAL SURGERY 2024:101902. [PMID: 38685354 DOI: 10.1016/j.jormas.2024.101902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Accepted: 04/27/2024] [Indexed: 05/02/2024]
Abstract
OBJECTIVES The purpose of this study is to determine the feasibility of polyetheretherketone-based dental implants, and analyze the stress and strain around different kinds of dental implants by finite element analysis. METHODS The radiographic data was disposed to models in Mimics 19.0. 3D models of implants, crowns and jawbones were established and combined in SolidWorks 2018. Appling axial and oblique loads of 100 N, cloud pictures were exported in Ansys Workbench 18.0 to calculate and analyze the stress and strain in and around different implants. RESULTS Oblique load tended to deliver more stress to bone tissue than axial load. The uniformity of stress distribution was the best for 30% short carbon fiber reinforced polyetheretherketone implants at axial and buccolingual directions. Stress shielding phenomenon occurred at the neck of 60% continuous carbon fiber reinforced polyetheretherketone and titanium implants. Stress concentration appeared in PEEK implants and the load of bone tissue would aggravate. CONCLUSIONS 30% short carbon fiber reinforced polyetheretherketone implants demonstrate a more uniform stress distribution in bone-implant contact and surrounding bone than titanium. Stress shielding and stress concentration may be avoided in bone-implant interface and bone tissue. Bone disuse-atrophy may be inhibited in PEEK-based implants.
Collapse
Affiliation(s)
- Zhe Zhou
- Hospital of Stomatology, Jilin University, Changchun, 130021, China.
| | - Ruining Shi
- Hospital of Stomatology, Jilin University, Changchun, 130021, China.
| | - Junqi Wang
- Hospital of Stomatology, Jilin University, Changchun, 130021, China.
| | - Xiao Han
- Hospital of Stomatology, Jilin University, Changchun, 130021, China.
| | - Weijia Gao
- Hospital of Stomatology, Jilin University, Changchun, 130021, China.
| | - Junjie Jiao
- Hospital of Stomatology, Jilin University, Changchun, 130021, China.
| | - Yuanzheng Qi
- Hospital of Stomatology, Jilin University, Changchun, 130021, China.
| | - Yongli Li
- Hospital of Stomatology, Jilin University, Changchun, 130021, China.
| | - Yanmin Zhou
- Hospital of Stomatology, Jilin University, Changchun, 130021, China; Jilin Province Key Laboratory of Tooth Development and Bone Remodeling, Changchun, 130021, China.
| | - Jinghui Zhao
- Hospital of Stomatology, Jilin University, Changchun, 130021, China; Jilin Province Key Laboratory of Tooth Development and Bone Remodeling, Changchun, 130021, China.
| |
Collapse
|
4
|
Barreto LAL, Grangeiro MTV, Prado PHCO, Bottino MA, Dal Piva AMDO, Ramos NDC, Tribst JPM, Junior LN. Effect of Finishing Protocols on the Surface Roughness and Fatigue Strength of a High-Translucent Zirconia. Int J Dent 2023; 2023:8882878. [PMID: 37780934 PMCID: PMC10541300 DOI: 10.1155/2023/8882878] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 08/16/2023] [Accepted: 08/29/2023] [Indexed: 10/03/2023] Open
Abstract
Purpose In case of need for esthetical improvement of zirconia restorations, an individualization using extrinsic staining can be applied. This study aimed to evaluate the surface roughness and fatigue strength (survival) of high-translucency zirconia (3Y-TZP, YZ®HT, Vita Zanhfabrik) with extrinsic characterization and/or glaze. Methods Sixty (60) zirconia discs (12 × 1.2 mm) were obtained, sintered, and randomly distributed among three groups (n = 20) according to the surface finishing protocol: C (control), C + G (extrinsic characterization followed by a glaze layer), and G (glaze layer). The surface roughness (Ra) was analyzed with a contact profilometer. Subsequently, the specimens were subjected to a fatigue load profile starting at 120 N during 20,000 cycles at 4 Hz frequency, with a 5% increase at each step until failure. The failed specimens were evaluated under a stereomicroscope. Surface roughness analysis was evaluated by using one-way ANOVA and post hoc Tukey tests (95%); while fatigue survival probability was analyzed with Kaplan-Meier and Mantel-Cox (log- rank, 95%). Results One-way ANOVA revealed that surface roughness was affected by the finishing protocol, where C + G showed the highest mean value (0.46 ± 0.18 µm)A followed by G (0.30 ± 0.10 µm)B, and C (0.19 ± 0.02 µm)C. While for fatigue strength, the G protocol presented a higher mean value (243.00, and 222.36-263.63)A, followed by C + G (192.75 and 186.61-198.88)B and C (172.50 and 159.43-185.56)C. Conclusion Surface finishing protocols modify the surface roughness and fatigue strength of high-translucent zirconia. Regardless of the surface roughness, both glazing protocols improved the ceramic fatigue strength, favoring the restoration's long-term survival.
Collapse
Affiliation(s)
- Larissa Araújo Lopes Barreto
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), Eng. Francisco José Longo Avenue, 777, São José dos Campos, SP, Brazil
| | - Manassés Tercio Vieira Grangeiro
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), Eng. Francisco José Longo Avenue, 777, São José dos Campos, SP, Brazil
| | - Pedro Henrique Condé Oliveira Prado
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), Eng. Francisco José Longo Avenue, 777, São José dos Campos, SP, Brazil
| | - Marco Antonio Bottino
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), Eng. Francisco José Longo Avenue, 777, São José dos Campos, SP, Brazil
| | - Amanda Maria de Oliveira Dal Piva
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, Netherlands
| | - Nathalia de Carvalho Ramos
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), Eng. Francisco José Longo Avenue, 777, São José dos Campos, SP, Brazil
| | - João Paulo Mendes Tribst
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, Netherlands
| | - Lafayette Nogueira Junior
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), Eng. Francisco José Longo Avenue, 777, São José dos Campos, SP, Brazil
| |
Collapse
|
5
|
Silva Júnior EV, Basting RT, Turssi CP, França FM. Precision of polyether ether ketone (PEEK) or cobalt-chrome implant bar fit to implants after mechanical cycling. ACTA ODONTOLOGICA LATINOAMERICANA : AOL 2023; 36:71-77. [PMID: 37776503 PMCID: PMC10557084 DOI: 10.54589/aol.36/2/71] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Accepted: 05/01/2023] [Indexed: 10/02/2023]
Abstract
Based on its mechanical properties, PEEK (polyether-ether-ketone) might be useful in restorative procedures. In oral rehabilitation, its viability has been studied mainly for prostheses and dental implants. AIM The aim of this study was to evaluate the fit accuracy of dental implant bars made of either PEEK or cobalt-chrome submitted to cycling mechanics. MATERIALS AND METHOD This was an experimental in vitro study, where units were treated with two implants and mini-abutments, joined by cobalt-chrome or polyether-ether-ketone PEEK bars. A total 20 bars were prepared (n=10 per group) and subjected to mechanical cycling tests (1 million cycles on the distal cantilever of the bar in the vertical direction, 120N and sinusoidal loading, at a frequency of 2Hz). The fit at the abutment/implant interface was measured before and after cycling, and the counter-torque of the vertical screw of the mini abutments was measured after cycling, using a digital torquemeter. Data were analyzed by three-way ANOVA and Tukey's test at 5% significance level. RESULTS No statistically significant interaction was found among the three factors considered (bar material, implant positioning and mechanical cycling) (p = 0.592). No significant difference was identified in the interaction between bar material and implant positioning (p = 0.321), or between implant positioning and mechanical cycling (p = 0.503). The association between bar material and mechanical cycling was statistically significant (p = 0.007), with the cobalt-chrome bar resulting in greater misfit with mechanical cycling. There was no difference in counter-torque values between groups. CONCLUSIONS The PEEK bar provided better fit of the mini abutments to the implants, even after mechanical cycling. The counter-torque of the screws was similar in all scenarios considered.
Collapse
Affiliation(s)
| | - Roberta T Basting
- Faculdade São Leopoldo Mandic, Programa de Pós-Graduação, Campinas, Brasil
| | - Cecilia P Turssi
- Faculdade São Leopoldo Mandic, Programa de Pós-Graduação, Campinas, Brasil
| | - Fabiana Mg França
- Faculdade São Leopoldo Mandic, Programa de Pós-Graduação, Campinas, Brasil.
| |
Collapse
|
6
|
Shash YH, El-Wakad MT, El-Dosoky MAA, Dohiem MM. Evaluation of stresses on mandible bone and prosthetic parts in fixed prosthesis by utilizing CFR-PEEK, PEKK and PEEK frameworks. Sci Rep 2023; 13:11542. [PMID: 37460592 DOI: 10.1038/s41598-023-38288-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Accepted: 07/06/2023] [Indexed: 07/20/2023] Open
Abstract
Fixed prostheses are appropriate treatment solutions for edentulous patients. In fixed prostheses, following "All on four", titanium frameworks are commonly used to support the implants. However, the limitations of titanium have prompted researchers to search for alternative materials (e.g. polymers). This study applied finite element investigation to evaluate the stress distribution in the parts of fixed prosthesis and the surrounding bone tissue, using polymeric frameworks in place of titanium, and different densities of spongy bone. As, the success of fixed prosthesis was predicted to be influenced also by bone quality, particularly spongy bone density. Fixed prosthesis was constructed on edentulous mandible, then different frameworks (CFR-PEEK 60%, CFR-PEEK 30%, PEKK, and PEEK) were stimulated instead of titanium, under 300N unilateral and bilateral forces. Three densities of spongy bone were stimulated which are normal, low and high. The choice of framework material depended on the density of spongy bone. Moreover, PEEK framework showed the lowest stress values on bone tissues and the highest stress values on mucosa. All frameworks could be used in the fixed prosthesis, in the cases of normal and high densities of spongy bone. In low-density case, soft frameworks (PEKK and PEEK) were recommended to reduce the stresses generated on bone tissues.
Collapse
Affiliation(s)
- Yomna H Shash
- Department of Biomedical Engineering, Helwan University, Cairo, Egypt.
| | - Mohamed T El-Wakad
- Faculty of Engineering and Technology, Future University in Egypt, Cairo, Egypt
| | | | - Mohamed M Dohiem
- Department of Prosthodontics, Zagazig University, Zagazig, Egypt
| |
Collapse
|
7
|
Costa EFA, Penteado MM, Maior BS. Comparative analysis of biomechanical response between zygomatic implant and Facco technique through the three-dimensional finite element method. J Clin Exp Dent 2023; 15:e96-e101. [PMID: 36911157 PMCID: PMC9994652 DOI: 10.4317/jced.59885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Accepted: 10/10/2022] [Indexed: 03/14/2023] Open
Abstract
Background The placement of zygomatic implants is an alternative used for rehabilitation of edentulous patients with atrophic maxilla. However, the complexity of the various techniques suggested in the literature requires high skill from surgeons. Aim: The objective of this research was to compare the biomechanical performance of traditional technique of zygomatic implant placement in relation to a new proposal, the Facco technique, through finite element analysis. Material and Methods A three-dimensional geometric model of the maxilla was input into computer-aided design software (Rhinoceros version 4.0 SR8). STL file of the geometric models of implants and components supplied by the company Implacil De Bortoli was converted to volumetric solids through reverse engineering by RhinoResurf software (Rhinoceros version 4.0 SR8). Three groups were modeled: traditional technique, Facco technique without frictional contact and Facco technique with frictional contact, following the recommended position in each technique for implant placement. All models received a maxillary bar. Groups were exported to the computer-aided engineering software ANYSYS 19.2, in step format. Mechanical static structural analysis was requested with occlusal load of 120N. All elements were considered isotropic, homogeneous, and linearly elastic. Contacts were considered ideal and system fixation was considered at the bone tissue base. Results There is similarity between the techniques. Microdeformation values capable of generating undesirable bone resorption were not observed in both techniques. Highest values in the posterior region of Facco technique were computed at the angle of part B close to the posterior implant. Conclusions Biomechanical behaviors of the two evaluated zygomatic implant techniques are similar. Prosthetic abutment (pilar Z) modifies the distribution of stresses over the zygomatic implant body. Highest stress peak was found in the pilar Z, but it is within acceptable physiological limits. Key words:Atrophic maxilla, zygomatic implants, surgical techniques, pilar Z, dental implants.
Collapse
Affiliation(s)
- Elton-Facco-Alves Costa
- MSc and PhD in Dental Implantology from São Leopoldo Mandic University, Campinas, São Paulo, Brazil
| | - Marcela-Moreira Penteado
- PhD in Prosthesis from Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University, São José Dos Campos, São Paulo, Brazil
| | - Bruno-Sotto Maior
- Adjunt Professor Faculty of Dentistry of University Federal of Juiz de Fora
| |
Collapse
|
8
|
Liu Y, Fang M, Zhao R, Liu H, Li K, Tian M, Niu L, Xie R, Bai S. Clinical Applications of Polyetheretherketone in Removable Dental Prostheses: Accuracy, Characteristics, and Performance. Polymers (Basel) 2022; 14:polym14214615. [PMID: 36365609 PMCID: PMC9654455 DOI: 10.3390/polym14214615] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 10/19/2022] [Accepted: 10/25/2022] [Indexed: 11/06/2022] Open
Abstract
The high-performance thermoplastic polyetheretherketone (PEEK) has excellent mechanical properties, biocompatibility, chemical stability, and radiolucency. The present article comprehensively reviews various applications of PEEK in removable dental prostheses, including in removable partial dentures (RPDs) (frameworks and clasps), double-crown RPDs, and obturators. The clinical performance of PEEK in removable dental prostheses is shown to be satisfactory and promising based on the short-term clinical evidence and technical complications are scarce. Moreover, the accuracy of RPDs is a vital factor for their long-term success rate. PEEK in removable dental prostheses is fabricated using the conventional lost-wax technique and CAD/CAM milling, which produces a good fit. Furthermore, fused deposition modeling is considered to be one of the most practical additive techniques. PEEK in removable prostheses produced by this technique exhibits good results in terms of the framework fit. However, in light of the paucity of evidence regarding other additive techniques, these manufacturers cannot yet be endorsed. Surface roughness, bacterial retention, color stability, and wear resistance should also be considered when attempting to increase the survival rates of PEEK removable prostheses. In addition, pastes represent an effective method for PEEK polishing to obtain a reduced surface roughness, which facilitates lower bacterial retention. As compared to other composite materials, PEEK is less likely to become discolored or deteriorate due to wear abrasion.
Collapse
Affiliation(s)
- Yuchen Liu
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Ming Fang
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Correspondence: (M.F.); (S.B.)
| | - Ruifeng Zhao
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Digital Dentistry Center, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Hengyan Liu
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Kangjie Li
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Min Tian
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Lina Niu
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Rui Xie
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Digital Dentistry Center, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Shizhu Bai
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Digital Dentistry Center, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Correspondence: (M.F.); (S.B.)
| |
Collapse
|
9
|
Khurshid Z, Nedumgottil BM, Ali RMM, Bencharit S, Najeeb S. Insufficient Evidence to Ascertain the Long-Term Survival of PEEK Dental Prostheses: A Systematic Review of Clinical Studies. Polymers (Basel) 2022; 14:polym14122441. [PMID: 35746022 PMCID: PMC9231096 DOI: 10.3390/polym14122441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 06/11/2022] [Accepted: 06/15/2022] [Indexed: 11/16/2022] Open
Abstract
Introduction: Polyetheretherketone (PEEK) is a polymer that is used in the construction of orthopaedic and dental implants. It is also used to construct removable and fixed dental prostheses due to its superior mechanical and esthetic properties compared to conventional materials. This systematic review aims to analyse and appraise the literature concerning PEEK dental prostheses critically. Methods: The following focused question was constructed ‘Are dental prostheses made of PEEK inferior to those made of other materials in terms of clinical- and patient-reported outcomes?’. The CONSORT (Consolidated Standards of Reporting Trials) tool was used for the quality assessment of the randomised clinical trials. The STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) quality assessment tool was used to assess the quality of observational studies and the case reports were evaluated using the CARE (Case Report) guidelines. Results: A total of 12 studies were included in this review. Two case studies received an overall grade of medium and the overall quality of six studies was graded as ‘low’. All three observational studies and the only randomised controlled trial received scores of ‘medium’. Conclusion: PEEK-based dental prostheses may provide a viable and more esthetic alternative to conventional prosthodontic appliances. However, within the limitations of this study is the evidence to ascertain the long-term viability of PEEK-based dental prostheses. Future studies should focus on conducting large-scale, multicenter trials to compare the survival rate of PEEK prostheses to that of conventionally available prosthodontic appliances.
Collapse
Affiliation(s)
- Zohaib Khurshid
- Department of Prosthodontics and Dental Implantology, College of Dentistry, King Faisal University, Al-Ahsa 31982, Saudi Arabia; (B.M.N.); (R.M.M.A.)
- Correspondence:
| | - Binoy Mathews Nedumgottil
- Department of Prosthodontics and Dental Implantology, College of Dentistry, King Faisal University, Al-Ahsa 31982, Saudi Arabia; (B.M.N.); (R.M.M.A.)
| | - Ramy Moustafa Moustafa Ali
- Department of Prosthodontics and Dental Implantology, College of Dentistry, King Faisal University, Al-Ahsa 31982, Saudi Arabia; (B.M.N.); (R.M.M.A.)
- Department of Removable Prosthodontics, Faculty of Dentistry, Fayoum University, Fayoum 2933110, Egypt
| | - Sompop Bencharit
- VCU Philips Institute for Oral Health Research, Department of Biomedical Engineering, School of Dentistry, College of Engineering, Virginia Commonwealth University, Richmond, VA 23298, USA;
| | - Shariq Najeeb
- Schulich School of Medicine and Dentistry, University of Western Ontario, London, ON N6A 3K7, Canada;
| |
Collapse
|
10
|
Comparative Stress Analysis of Polyetherketoneketone (PEKK) Telescopic Crowns Supported by Different Primary Crown Materials. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12073446] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
The present study aimed to investigate the stress distribution of secondary telescopic crowns made of polyetherketoneketone (PEKK) combined with different primary crown (PC) materials (Zirconia, CoCr, Titanium, and PEKK) using finite element analysis. The geometric model was composed of bone tissue, periodontal ligament, root dentin, cement layer, primary crown, and secondary telescopic crown (SC). A total of four models were evaluated in which the secondary crowns were simulated in PEKK. The models were designed in CAD software and exported to the computer aided engineering software for the statistic structural analysis simulation. The materials were considered isotropic, with linear behavior and elastic properties. The model was fixed in the bone base and the load was applied at the occlusal surface of the crowns with 600 N. The results were required in von-Mises stress for the primary crown, secondary crown, cement layer, and Equivalent Strain to the periodontal ligament and bone tissue. Results show that the material influenced the stress distribution. The higher the PC elastic modulus, the higher the stress magnitude on the SC and cement layer. In the present study, the use of milled high-density polymer for primary crown presented a promising biomechanical behavior as an alternative material for double-crown design.
Collapse
|
11
|
Influence of Framework Material and Posterior Implant Angulation in Full-Arch All-on-4 Implant-Supported Prosthesis Stress Concentration. Dent J (Basel) 2022; 10:dj10010012. [PMID: 35049610 PMCID: PMC8774799 DOI: 10.3390/dj10010012] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Revised: 12/27/2021] [Accepted: 01/12/2022] [Indexed: 12/10/2022] Open
Abstract
This study evaluated the influence of distal implants angulation and framework material in the stress concentration of an All-on-4 full-arch prosthesis. A full-arch implant-supported prosthesis 3D model was created with different distal implant angulations and cantilever arms (30° with 10-mm cantilever; 45° with 10-mm cantilever and 45° with 6-mm cantilever) and framework materials (Cobalt–chrome [CoCr alloy], Yttria-stabilized tetragonal zirconia polycrystal [Y-TZP] and polyetheretherketone [PEEK]). Each solid was imported to computer-aided engineering software, and tetrahedral elements formed the mesh. Material properties were assigned to each solid with isotropic and homogeneous behavior. The contacts were considered bonded. A vertical load of 200 N was applied in the distal region of the cantilever arm, and stress was evaluated in Von Misses (σVM) for prosthesis components and the Maximum (σMAX) and Minimum (σMIN) Principal Stresses for the bone. Distal implants angled in 45° with a 10-mm cantilever arm showed the highest stress concentration for all structures with higher stress magnitudes when the PEEK framework was considered. However, distal implants angled in 45° with a 6-mm cantilever arm showed promising mechanical responses with the lowest stress peaks. For the All-on-4 concept, a 45° distal implants angulation is only beneficial if it is possible to reduce the cantilever’s length; otherwise, the use of 30° should be considered. Comparing with PEEK, the YTZP and CoCr concentrated stress in the framework structure, reducing the stress in the prosthetic screw.
Collapse
|
12
|
Villefort RF, Diamantino PJS, von Zeidler SLV, Borges ALS, Silva-Concílio LR, de Siqueira Ferreira Anzaloni Saavedra G, Tribst JPM. Mechanical Response of PEKK and PEEK As Frameworks for Implant-Supported Full-Arch Fixed Dental Prosthesis: 3D Finite Element Analysis. Eur J Dent 2021; 16:115-121. [PMID: 34560810 PMCID: PMC8890915 DOI: 10.1055/s-0041-1731833] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Objective
Polymeric framework represent an innovative approach for implant-supported dental prostheses. However, the mechanical response of ultra-high performance polymers as frameworks for full-arch prostheses under the “all-on-four concept” remains unclear. The present study applied finite element analysis to examine the behavior of polyetherketoneketone (PEKK) and polyetheretherketone (PEEK) prosthetic frameworks.
Materials and Methods
A three-dimensional maxillary model received four axially positioned morse-taper implants, over which a polymeric bar was simulated. The full-arch prosthesis was created from a previously reported database model, and the imported geometries were divided into a mesh composed of nodes and tetrahedral elements in the analysis software. The materials were assumed as isotropic, elastic, and homogeneous, and all contacts were considered bonded. A normal load (500 N magnitude) was applied at the occlusal surface of the first left molar after the model was fixed at the base of the cortical bone. The microstrain and von-Mises stress were selected as criteria for analysis.
Results
Similarities in the mechanical response were observed in both framework for the peri-implant tissue, as well as for stress generated in the implants (263–264 MPa) and abutments (274–273 MPa). The prosthetic screw and prosthetic base concentrated more stress with PEEK (211 and 58 MPa, respectively) than with PEKK (192 and 49 MPa), while the prosthetic framework showed the opposite behavior (59 MPa for PEEK and 67 MPa for PEKK).
Conclusion
The main differences related to the mechanical behavior of PEKK and PEEK frameworks for full-arch prostheses under the “all-on-four concept” were reflected in the prosthetic screw and the acrylic base. The superior shock absorbance of PEKK resulted in a lower stress concentration on the prosthetic screw and prosthetic base. This would clinically represent a lower fracture risk on the acrylic base and screw loosening. Conversely, lower stress concentration was observed on PEEK frameworks.
Collapse
Affiliation(s)
- Regina Furbino Villefort
- Federal University of Espírito Santo, Rede Nordeste de Biotecnologia, Vitória, Espírito Santo, Brazil
| | - Pedro Jacy Santos Diamantino
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University, São José dos Campos, São Paulo, Brazil
| | | | - Alexandre Luiz Souto Borges
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University, São José dos Campos, São Paulo, Brazil
| | | | | | | |
Collapse
|
13
|
Mousa MA, Abdullah JY, Jamayet NB, Alam MK, Husein A. Biomechanical Stress in Obturator Prostheses: A Systematic Review of Finite Element Studies. BIOMED RESEARCH INTERNATIONAL 2021; 2021:6419774. [PMID: 34447852 PMCID: PMC8384539 DOI: 10.1155/2021/6419774] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Accepted: 08/02/2021] [Indexed: 11/17/2022]
Abstract
AIM This systematic review is aimed at investigating the biomechanical stress that develops in the maxillofacial prostheses (MFP) and supporting structures and methods to optimize it. Design and Methods. A literature survey was conducted for full-text English articles which used FEA to examine the stress developed in conventional and implant-assisted MFPs from January 2010 to December 2020. RESULTS 87 articles were screened to get an update on the desired information. 74 were excluded based on a complete screening, and finally, 13 articles were recruited for complete reviewing. Discussion. The MFP is subjected to stress, which is reflected in the form of compressive and tensile strengths. The stress is mainly concentrated the resection line and around the apices of roots of teeth next to the defect. Diversity of designs and techniques were introduced to optimize the stress distribution, such as modification of the clasp design, using materials with different mechanical properties for dentures base and retainer, use of dental (DI) and/or zygomatic implants (ZI), and free flap reconstruction before prosthetic rehabilitation. CONCLUSION Using ZI in the defective side of the dentulous maxillary defect and defective and nondefective side of the edentulous maxillary defect was found more advantageous, in terms of compression and tensile stress and retention, when compared with DI and free flap reconstruction.
Collapse
Affiliation(s)
- Mohammed A. Mousa
- Prosthodontic Unit, School of Dental Sciences, Universiti Sains Malaysia, 16150 Kubang Kerian, Kelantan, Malaysia
- Department of Prosthetic Dental Sciences, College of Dentistry, Jouf University, Sakakah, Jouf Province, Saudi Arabia
| | - Johari Yap Abdullah
- Craniofacial Imaging Laboratory, School of Dental Sciences, Universiti Sains Malaysia, 16150 Kubang Kerian, Kelantan, Malaysia
| | - Nafij B. Jamayet
- Division of Restorative Dentistry, International Medical University, Bukit Jalil, Jalan Jalil Perkasa-19, 57000 Kuala Lumpur, Malaysia
| | | | - Adam Husein
- Prosthodontic Unit, School of Dental Sciences, Universiti Sains Malaysia, 16150 Kubang Kerian, Kelantan, Malaysia
| |
Collapse
|
14
|
Haroun F, Ozan O. Evaluation of Stresses on Implant, Bone, and Restorative Materials Caused by Different Opposing Arch Materials in Hybrid Prosthetic Restorations Using the All-on-4 Technique. MATERIALS 2021; 14:ma14154308. [PMID: 34361502 PMCID: PMC8348490 DOI: 10.3390/ma14154308] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/26/2021] [Revised: 07/17/2021] [Accepted: 07/28/2021] [Indexed: 12/17/2022]
Abstract
The long-term success of dental implants is greatly influenced by the use of appropriate materials while applying the “All-on-4” concept in the edentulous jaw. This study aims to evaluate the stress distribution in the “All-on-4” prosthesis across different material combinations using three-dimensional finite element analysis (FEA) and to evaluate which opposing arch material has destructive effects on which prosthetic material while offering certain recommendations to clinicians accordingly. Acrylic and ceramic-based hybrid prosthesis have been modelled on a rehabilitated maxilla using the “All-on-4” protocol. Using different materials and different supports in the opposing arch (natural tooth, and implant/ceramic, and acrylic), a multi-vectorial load has been applied. To measure stresses in bone, maximum and minimum principal stress values were calculated, while Von Mises stress values were obtained for prosthetic materials. Within a single group, the use of an acrylic implant-supported prosthesis as an antagonist to a full arch implant-supported prosthesis yielded lower maximum (Pmax) and minimum (Pmin) principal stresses in cortical bone. Between different groups, maxillary prosthesis with polyetheretherketone as framework material showed the lowest stress values among other maxillary prostheses. The use of rigid materials with higher moduli of elasticity may transfer higher stresses to the peri implant bone. Thus, the use of more flexible materials such as acrylic and polyetheretherketone could result in lower stresses, especially upon atrophic bones.
Collapse
Affiliation(s)
- Feras Haroun
- Correspondence: ; Tel.: +90-548-828-66-79 or +90-542-888-99-90 or +965-97170419
| | | |
Collapse
|
15
|
Influence of Polymeric Restorative Materials on the Stress Distribution in Posterior Fixed Partial Dentures: 3D Finite Element Analysis. Polymers (Basel) 2021; 13:polym13050758. [PMID: 33670991 PMCID: PMC7957672 DOI: 10.3390/polym13050758] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Revised: 02/12/2021] [Accepted: 02/12/2021] [Indexed: 01/06/2023] Open
Abstract
Background: This study evaluated the effect of interim restorative materials (acrylic resin (AR), resin composite (RC) or polyetheretherketone (PEEK) for dental computer-aided design/computer-aided manufacturing (CAD/CAM)) on the stress distribution of a posterior three-unit fixed partial denture. Methods: The abutment teeth (first molar and first premolar) were modeled using the BioCAD protocol containing 1.5 mm of axial reduction and converging axial walls. A static structural analysis was performed in the computer-aided engineering software, and the Maximum Principal Stress criterion was used to analyze the prosthesis and the cement layers of both abutment teeth. The materials were considered isotropic, linearly elastic, homogeneous and with bonded contacts. An axial load (600 N) was applied to the occlusal surface of the second premolar. Results: Regardless of the restorative material, the region of the prosthetic connectors showed the highest tensile stress magnitude. The highest stress peak was observed with the use of RC (129 MPa) compared to PEEK and AR. For the cement layers, RC showed the lowest values in the occlusal region (7 MPa) and the highest values for the cervical margin (14 MPa) compared to PEEK (21 and 12 MPa) and AR (21 and 13 MPa). Conclusions: Different interim restorative materials for posterior fixed partial dentures present different biomechanical behavior. The use of resin composite can attenuate the stress magnitude on the cement layer, and the use of acrylic resin can attenuate the stress magnitude on the connector region.
Collapse
|