Schallhorn SC, Teenan D, Venter JA, Schallhorn JM, Hannan SJ. Early Clinical Experience with a New Hydrophobic Acrylic Single-Piece Monofocal Intraocular Lens. Clin Ophthalmol 2023; 17:3419-3427. [PMID: 38026603 PMCID: PMC10655610 DOI: 10.2147/opth.s433530] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Accepted: 10/05/2023] [Indexed: 12/01/2023] Open
Abstract
Purpose To evaluate early clinical outcomes and adverse events (AEs) in cataract patients following implantation of a monofocal hydrophobic acrylic IOL with a new optimized non-constant aberration-correcting design (CT LUCIA 621P). Methods This retrospective study included patients with visually significant cataracts who underwent implantation of the CT LUCIA 621P IOL. Refraction, corrected (CDVA) and uncorrected (UDVA) visual acuity of the last available visit were used in the analysis. Intraoperative and postoperative AEs of the cohort were reviewed. Results A total of 191 eyes of 133 patients with the mean age of 70.2±11.2 years were included in this study. The mean follow-up time of the last available visit was 1.7±1.3 months. The mean postoperative monocular UDVA was 0.09±0.16 logMAR (≈20/25), and 74.9% (143/191) eyes achieved ≥20/25 UDVA. The percentage of eyes with manifest spherical equivalent (MSE) within ±0.50D and ±1.00D of emmetropia was 84.8% (162/191) and 98.4% (188/191), respectively. Linear regression of attempted vs achieved MSE showed a tight relationship, with the coefficient of determination close to 1 (R2=0.99), indicating a very predictable refractive correction. The reported AEs were those typically expected after cataract surgery. There were no AEs related to intraoperative manipulation with the IOL/injector or to postoperative stability of the IOL in the capsular bag. No eye lost ≥2 lines of CDVA. Conclusion The implantation of CT LUCIA 621P resulted in good refractive predictability and visual outcomes. No IOL-related adverse events were reported.
Collapse
Affiliation(s)
- Steven C Schallhorn
- Department of Ophthalmology, University of California, San Francisco, CA, USA
- Optical Express, Glasgow, UK
- Carl Zeiss Meditec, Inc, Dublin, CA, USA
| | | | | | - Julie M Schallhorn
- Department of Ophthalmology, University of California, San Francisco, CA, USA
- F.I. Proctor Foundation, University of California, San Francisco, CA, USA
| | | |
Collapse
|
2
|
García-Tomás B, Marín-Sánchez JM, García-Elskamp C, Alcon-Ruiz E, Montesinos-López L, García Martínez-Lozano B. Clinical Outcomes of a Monofocal, Optimized, Aspheric, Hydrophobic Acrylic Intraocular Lens Implant. Clin Ophthalmol 2023; 17:3215-3224. [PMID: 37915319 PMCID: PMC10617528 DOI: 10.2147/opth.s434378] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Accepted: 10/02/2023] [Indexed: 11/03/2023] Open
Abstract
Purpose To evaluate the refractive and visual outcomes of eyes implanted with monofocal, optimized, aspheric, hydrophobic acrylic intraocular lenses (IOL) following cataract surgery. Methods The study assessed 55 eyes implanted with CT LUCIA® 621P IOLs (Carl Zeiss Meditec AG, Jena, Germany) at 3-months postsurgery. The main outcome measures were refractive error, monocular corrected distance visual acuity (CDVA), monocular uncorrected distance visual acuity (UDVA), photopic and mesopic contrast sensitivity, and wavefront aberrations. Patients were asked to complete the Catquest-9SF questionnaire. Results At 3 months, the cumulative Snellen visual acuity was 20/20 in 94.55% of eyes and 20/25 or better in 100%. The difference between the UDVA and CDVA was either the same (70.91%) or better (29.09%) in all eyes. The mean Snellen decimal UDVA and DCVA were 1.07 ± 0.15 and 1.13 ± 0.11, respectively. The safety and efficacy indexes were 1.48 and 1.40, respectively. 47.27% of eyes showed a spherical equivalent ±0.13 D, with 92.73% of the eyes were within ±0.50 D and all eyes were within ±1.00 D. The mean spherical equivalent was -0.03 ± 0.30 D and the mean refractive cylinder -0.36 ± 0.34 D. The log photopic and mesopic contrast sensitivity functions were good and similar for all spatial frequencies. All patients reported being either fairly satisfied (score 3) or very satisfied (score 4) with their vision (mean = 3.64 ± 0.49). No intra- and postoperative complications were reported during the 3 months of follow-up. Conclusion The current study demonstrates that excellent visual and refractive outcomes, as well as patient satisfaction, can be achieved after cataract surgery with optimized, aspheric CT LUCIA 621P monofocal IOLs.
Collapse
|
3
|
Fernández-Vigo JI, Serrano González-Peramato MT, Nunila Gómez-de-Liaño C, Sánchez-Guillén I, Fernández-Vigo JÁ, Macarro-Merino A. Glistening on intraocular lenses: A review. ARCHIVOS DE LA SOCIEDAD ESPANOLA DE OFTALMOLOGIA 2023; 98:493-506. [PMID: 37369324 DOI: 10.1016/j.oftale.2023.06.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2023] [Accepted: 06/07/2023] [Indexed: 06/29/2023]
Abstract
The glistening in intraocular lenses (IOLs) is a phenomenon in which tiny water-filled microvacuoles (MVs) form within the IOL material, causing light to scatter and create a sparkling or shimmering effect. The presence of glistening is common in many types of IOL materials and models and has been extensively studied in recent years to determine its incidence, risk factors, evolution, and possible clinical relevance. Classically, it has been studied in vitro in the laboratory or by means of photography obtained with a slit lamp, but these were techniques that required either specific technology or an expert explorer, complex image processing, and required a lot of time. In recent years, proposals based on the Scheimpflug camera and optical coherence tomography have emerged to try to simplify the analysis of glistening in IOLs. It has been described that the manufacturing process, the hydrophobic acrylic material, or the time since surgery are risk factors for the appearance of glistening. In addition, many issues related to this phenomenon are still unknown, such as not knowing from what number of points or their size they may have relevance to visual function since different optical phenomena related to glistening have been described on the IOLs.
Collapse
Affiliation(s)
- J I Fernández-Vigo
- Servicio de Oftalmología, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria (IdISSC), Madrid, Spain; Centro Internacional de Oftalmología Avanzada, Madrid, Spain.
| | | | - C Nunila Gómez-de-Liaño
- Servicio de Oftalmología, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria (IdISSC), Madrid, Spain
| | - I Sánchez-Guillén
- Servicio de Oftalmología, Hospital Perpetuo Socorro, Badajoz, Spain; Centro Internacional de Oftalmología Avanzada, Badajoz, Spain
| | - J Á Fernández-Vigo
- Centro Internacional de Oftalmología Avanzada, Madrid, Spain; Centro Internacional de Oftalmología Avanzada, Badajoz, Spain; Departamento de Oftalmología, Facultad de Medicina, Universidad de Extremadura, Badajoz, Spain
| | - A Macarro-Merino
- Centro Internacional de Oftalmología Avanzada, Madrid, Spain; Centro Internacional de Oftalmología Avanzada, Badajoz, Spain
| |
Collapse
|
4
|
Stanojcic N, Hull CC, Mangieri E, Little N, O'Brart D. A new software for automated counting of glistenings in intraocular lenses in vivo. Int J Ophthalmol 2023; 16:1237-1242. [PMID: 37602355 PMCID: PMC10398534 DOI: 10.18240/ijo.2023.08.08] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Accepted: 05/24/2023] [Indexed: 08/22/2023] Open
Abstract
AIM To assess the performance of a bespoke software for automated counting of intraocular lens (IOL) glistenings in slit-lamp images. METHODS IOL glistenings from slit-lamp-derived digital images were counted manually and automatically by the bespoke software. The images of one randomly selected eye from each of 34 participants were used as a training set to determine the threshold setting that gave the best agreement between manual and automatic grading. A second set of 63 images, selected using randomised stratified sampling from 290 images, were used for software validation. The images were obtained using a previously described protocol. Software-derived automated glistenings counts were compared to manual counts produced by three ophthalmologists. RESULTS A threshold value of 140 was determined that minimised the total deviation in the number of glistenings for the 34 images in the training set. Using this threshold value, only slight agreement was found between automated software counts and manual expert counts for the validating set of 63 images (κ=0.104, 95%CI, 0.040-0.168). Ten images (15.9%) had glistenings counts that agreed between the software and manual counting. There were 49 images (77.8%) where the software overestimated the number of glistenings. CONCLUSION The low levels of agreement show between an initial release of software used to automatically count glistenings in in vivo slit-lamp images and manual counting indicates that this is a non-trivial application. Iterative improvement involving a dialogue between software developers and experienced ophthalmologists is required to optimise agreement. The results suggest that validation of software is necessary for studies involving semi-automatic evaluation of glistenings.
Collapse
Affiliation(s)
- Nick Stanojcic
- Department of Ophthalmology, Guy's and St Thomas' NHS Foundation Trust, London SE1 7EH, UK
- Centre for Applied Vision Research, School of Health Sciences, University of London, London EC1V 0HB, UK
- King's College, London WC2R 2LS, UK
| | - Christopher C. Hull
- Centre for Applied Vision Research, School of Health Sciences, University of London, London EC1V 0HB, UK
| | | | | | - David O'Brart
- Department of Ophthalmology, Guy's and St Thomas' NHS Foundation Trust, London SE1 7EH, UK
- King's College, London WC2R 2LS, UK
| |
Collapse
|
5
|
Objective Classification of Glistening in Implanted Intraocular Lenses Using Optical Coherence Tomography: Proposal for a New Classification and Grading System. J Clin Med 2023; 12:jcm12062351. [PMID: 36983351 PMCID: PMC10057385 DOI: 10.3390/jcm12062351] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 03/10/2023] [Accepted: 03/15/2023] [Indexed: 03/22/2023] Open
Abstract
Purpose: To propose a classification of the glistening in intraocular lenses (IOL) using swept-source optical coherence tomography (SS-OCT) by means of a simple, objective and reproducible method that allows the quantification of the presence and severity of glistening. Methods: A cross-sectional study on a sample of 150 eyes of 150 patients who underwent cataract surgery in at least 600 days before the exam and attended a routine examination. Each subject was examined by SS-OCT after pupil dilation, identifying the presence of glistening or hyperreflective foci (HRF) in the central area of the IOL. The degree of glistening was classified into four categories: 0: ≤5 HRF; 1: 6 to 15 HRF; 2: 16 to 30 HRF; and 3: >30 HRF. The intra and interobserver reproducibility (intraclass correlation coefficient, ICC) in the quantification and classification of the glistening were calculated. The correlation between the horizontal and vertical scan of the IOL was also assessed. Results: Glistening was present in the IOL in 42.7% of the patients. The mean number of HRF or glistening microvacuoles was 10.4 ± 26.2 (range 0 to 239). In total, 63.3% of the IOLs had a grade 0, 20% grade a 1, 6.7% grade a 2 and 10% a grade 3. The intraobserver and interobserver reproducibility were very high, both for the absolute quantification of the glistening (ICC ≥ 0.994) and for the severity scale (ICC ≥ 0.967). There was an excellent correlation in the quantification of the IOL glistening between the horizontal and vertical scans (R ≥ 0.834; p < 0.001). Conclusions: The use of SS-OCT makes it possible to identify, quantify and classify IOL glistening in a simple, objective and reproducible way. This technique could provide relevant information for the study of the glistening on IOLs.
Collapse
|
6
|
Randomized multicenter trial to assess posterior capsule opacification and glistenings in two hydrophobic acrylic intraocular lenses. Sci Rep 2023; 13:2822. [PMID: 36805494 PMCID: PMC9938215 DOI: 10.1038/s41598-023-29855-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Accepted: 02/11/2023] [Indexed: 02/19/2023] Open
Abstract
To evaluate the long-term posterior capsule opacification (PCO) formation, and glistening rate of the HOYA Vivinex (XY1) IOL compared to Alcon AcrySof (SN60WF). In this prospective, multicentric, randomized, paired-eye, open-label study, we included 87 subjects that underwent cataract surgery with IOL implantation, with 67 patients completing the 3-year follow-up. The completer population consisted of 32 subjects implanted with XY1 and 35 implanted with SN60WF. Primary endpoints consisted of the evaluation of glistenings and measurement of PCO. Secondary outcomes included Best Corrected Distance Visual Acuity (BCVA), Contrast Acuity (CA), uncorrected visual acuities, subjective refraction, medical and lens complication rates, adverse events, and optical/visual symptoms. Follow-up visits occurred at 6-months, 1-, 2- and 3-years. At 3-years follow-up, mean PCO score was 0.121 ± 0.193 for eyes implanted with Vivinex versus 0.239 ± 0.463 for AcrySof (p = 0.026). The Vivinex IOL showed statistically significantly lower glistening occurrence through 3-years postoperatively (0.14 ± 0.26) compared to AcrySof (1.79 ± 1.43; p < 0.0001). Postoperative visual acuities improved from baseline in both IOL groups (p < 0.0001), and remained stable through the 3-year follow-up period. Eyes implanted with a HOYA Vivinex IOL exhibited significantly lower occurrence of glistening at 3-years versus Alcon AcrySof (p < 0.0001). Incidence of PCO was very low and comparable in both Vivinex and AcrySof eyes.
Collapse
|
7
|
Schallhorn SC, Bonilla M, Pantanelli SM. Outcomes of a multicenter U.S. clinical trial of a new monofocal single-piece hydrophobic acrylic IOL. J Cataract Refract Surg 2022; 48:1126-1133. [PMID: 35333839 PMCID: PMC9514744 DOI: 10.1097/j.jcrs.0000000000000943] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Accepted: 03/18/2022] [Indexed: 12/30/2022]
Abstract
PURPOSE To evaluate the safety and effectiveness of the CT LUCIA 611P intraocular lens (IOL) in patients with cataracts. SETTING 23 surgeons at 15 different clinical sites. DESIGN Prospective single-arm clinical trial. METHODS The study was conducted under an Investigational Device Exemption for premarket approval of a new hydrophobic acrylic IOL in the United States. Patients were followed for 12 months, and the main measured variables included uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction, and adverse events. RESULTS In total, 339 eyes of 339 patients were implanted with the study device, of which 310 (91.4%) reached the 12-month visit. The percentage of eyes within ±0.50 diopter (D) and ±1.00 D of emmetropia was 85.8% (266/310) and 96.8% (300/310), respectively. Manifest refraction spherical equivalent (MRSE) remained stable over the first year with the mean 12-month MRSE of -0.03 ± 0.45 D. The mean 12-month UDVA and CDVA were 0.09 ± 0.15 (≈20/25) and -0.02 ± 0.09 (≈20/19) logMAR, respectively. Of all patients, 99.4% (308/310) achieved postoperative CDVA ≥20/40. The incidence of Nd:YAG capsulotomy within the first year was 3.5% (11/310). Only 2 eyes had IOL tilt present at the 12-month postoperative visit with no associated visual symptoms. There were 2 cases of IOL decentration; one required removal of the IOL, whereas the other had no visual side effects related to decentration. There were no findings of glistening at any visit. CONCLUSIONS The CT LUCIA 611P IOL demonstrated excellent safety, efficacy, and stability of refractive outcomes. No significant issues related to the biocompatibility of the IOL material were observed.
Collapse
|
8
|
Hernández-Martínez A, Díaz-del-Rio MA, Ruiz-Santos M, Ruiz-Mesa R, Tañá-Rivero P. Refractive and Visual Outcomes of a Monofocal Non-Constant Aberration Aspheric Intraocular Lens. Clin Ophthalmol 2022; 16:2521-2530. [PMID: 35974903 PMCID: PMC9376001 DOI: 10.2147/opth.s373587] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Accepted: 07/20/2022] [Indexed: 11/23/2022] Open
Abstract
Purpose To evaluate the refractive and visual outcomes following cataract surgery and implantation of a new monofocal non-constant aberration aspheric intraocular lens (IOL). Methods Ninety eyes of 86 patients who underwent implantation the CT LUCIA 621P IOL (Carl Zeiss Meditec AG) were retrospectively analyzed in this study. Main outcome measures were refractive error and monocular corrected distance visual acuity (CDVA) and monocular uncorrected distance visual acuity (UDVA) values. Patients were evaluated at 1-month post-surgery and intra- and post-operative complications were recorded. Results Eighty percent of the eyes showed a CDVA of 20/25 or better before surgery. The postoperative mean values of monocular distance Snellen decimal UDVA and CDVA were 0.64±0.22 and 0.89±0.13, respectively. All eyes showed the same or better difference between UDVA and CDVA. In relation to the postoperative spherical equivalent, the highest percentage of eyes, 31.11%, was for the range between −0.50 and −0.14D followed by 22.22% for the ±0.13D range. Ninety percent of the eyes were within ±1.00 D and 73.33% of eyes within ±0.50 D. The mean postoperative spherical equivalent was −0.18±0.55D. 37.78% and 76.67% of the eyes showed a value ≤0.50 D and ≤1.00D, respectively, being the mean postoperative refractive cylinder −0.81±0.50D. No adverse events were reported in whole sample intra and postoperatively. Conclusion The present study shows that cataract surgery with an monofocal non-constant aberration aspheric IOL implantation resulted in good visual performance and refractive outcomes. This lens may be considered as a valid choice for patients in a standard-routine cataract surgery practice.
Collapse
Affiliation(s)
- Adrián Hernández-Martínez
- Ophthalmology Department, Oftalvist Huelva, Huelva, Spain
- Correspondence: Adrián Hernández-Martínez, Oftalvist Huelva, Pl. Ivonne Cazenave, 1, Huelva, 21004, Spain, Email
| | | | | | | | | |
Collapse
|
9
|
Tandogan T, Auffarth GU, Choi CY, Son HS, Khoramnia R. Comparative analysis of in vitro accelerated glistening formation in foldable hydrophobic intraocular lenses. Int Ophthalmol 2021; 41:3073-3080. [PMID: 34013467 PMCID: PMC8364527 DOI: 10.1007/s10792-021-01870-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2020] [Accepted: 04/15/2021] [Indexed: 01/30/2023]
Abstract
PURPOSE To analyse and compare the propensity to form glistenings in 4 different types of hydrophobic acrylic intraocular lenses (IOLs): Alcon AcrySof ® MA60AC, HOYA iSert® PC-60AD, Bausch&Lomb enVista, and Kowa Avansee™ PU6A. METHODS We used an accelerated laboratory method to create glistenings. IOLs were first immersed in saline at 45 °C for 24 h and then at 37 °C for 2.5 h. Microvacuole (MV) density and size were documented and calculated using an image analysis program. RESULTS Median density of glistenings [MV/mm2] for Alcon AcrySof ® MA60AC was 623 (range 507-804), for HOYA iSert® PC-60AD 1358 (range 684-2699), for Bausch&Lomb enVista 2 (range 1-2), and for Kowa Avansee™ PU6A 1 (range 1-4). The prevailing MV size was: 0-5 µm for Hoya IOLs, 5-10 µm for Alcon IOLs, 20-50 µm for Bausch&Lomb IOLs, and 5-50 µm for Kowa IOLs. CONCLUSIONS Glistenings could be induced in all studied IOLs using the accelerated laboratory method. The Alcon AcrySof ® MA60AC and HOYA iSert® PC-60AD IOLs showed MV of high density, while the glistenings in the Hoya IOLs were smaller in size compared to the Alcon IOLs. The MV density was minimal in the Bausch&Lomb enVista and Kowa Avansee™ PU6A IOLs. The propensity of the Alcon AcrySof ® MA60AC IOLs to form glistenings in vitro correlated with the findings of clinical results that are already published.
Collapse
Affiliation(s)
- Tamer Tandogan
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120 Heidelberg, Germany
| | - Gerd U. Auffarth
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120 Heidelberg, Germany
| | - Chul Young Choi
- Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Hyeck-Soo Son
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120 Heidelberg, Germany
| | - Ramin Khoramnia
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120 Heidelberg, Germany
| |
Collapse
|