1
|
Kaya S, Guven N, Unal YC, Ozkan S, Adanas C, Turkozu T, Danisman F, Ismailov U, Dundar A, Akdemir Z, Gokalp MA. Comparison of long-term clinical and radiologic outcomes of AperFix and fixed loop device fixation in anterior cruciate ligament reconstruction: A retrospective study. Medicine (Baltimore) 2025; 104:e41199. [PMID: 39833087 PMCID: PMC11749755 DOI: 10.1097/md.0000000000041199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2024] [Accepted: 12/16/2024] [Indexed: 01/22/2025] Open
Abstract
Anterior cruciate ligament reconstruction aims to improve knee stability and range of motion. The AperFix system consists of polymer components, and fixed-loop fixation is an established endoscopic technique. Our aim in this study was to compare the long-term clinical and radiological results of AperFix and fixed-loop fixation and to prove that the long-term results of the AperFix fixation method are at least as good as those of the fixed loop device. This retrospective study included 109 patients who underwent primary anterior cruciate ligament reconstruction using single bundled hamstring tendon grafts. Patients under 16 years of age, patients with incomplete follow-up, bilateral or other ligament injuries, inflammatory arthropathy, previous knee surgery, or concurrent meniscal treatment were excluded. Participants were divided into 2 groups according to femoral fixation methods: AperFix fixation (group 1, n = 55) and fixed loop device fixation (group 2, n = 54). All operations were performed by senior surgeons under general or spinal anesthesia. Postoperative rehabilitation started on day 1 and allowed patients to resume normal activities at 6 months. Outcomes were evaluated during follow-up, including knee range of motion, clinical scores [Lysholm, Cincinnati, Tegner, and International Knee Documentation Committee] and radiographic measurements of femoral tunnel width and length. Measurements were performed by 2 orthopedic surgeons to ensure reliability. This study evaluated 109 patients (55 in group 1, 54 in group 2) and found no statistically significant differences in demographic variables such as age, sex, body mass index, follow-up duration, or side distribution. Clinical outcomes, including anterior drawer test, Lachman test results, knee flexion-extension degrees, and Lysholm, Cincinnati, Tegner, and International Knee Documentation Committee scores, were similar between the groups (P > .05). Complications occurred in 8 cases (rerupture, infection, and deep vein thrombosis), with no significant correlation to the fixation method used (P = .506). Radiographic analysis revealed no significant differences in femoral tunnel width or length between the groups (P > .05). In our current study, no meaningful disparity was found between the AperFix and fixed loop device methods in terms of long-term clinical outcomes. As there are no long-term studies on the results of AperFix fixation in the literature, more studies on this subject are needed.
Collapse
Affiliation(s)
- Sehmuz Kaya
- Department of Orthopaedics and Traumatology, Faculty of Medicine, Van Yuzuncu Yil University, Van, Turkey
| | - Necip Guven
- Department of Orthopaedics and Traumatology, Faculty of Medicine, Van Yuzuncu Yil University, Van, Turkey
| | - Yunus Can Unal
- Department of Orthopaedics and Traumatology, Van Education And Research Hospital, Van, Turkey
| | - Sezai Ozkan
- Department of Orthopaedics and Traumatology, Faculty of Medicine, Van Yuzuncu Yil University, Van, Turkey
| | - Cihan Adanas
- Department of Orthopaedics and Traumatology, Faculty of Medicine, Van Yuzuncu Yil University, Van, Turkey
| | - Tulin Turkozu
- Department of Orthopaedics and Traumatology, Faculty of Medicine, Van Yuzuncu Yil University, Van, Turkey
| | - Ferhat Danisman
- Department of Orthopaedics and Traumatology, Van Education And Research Hospital, Van, Turkey
| | - Ulan Ismailov
- Department of Orthopaedics and Traumatology, Sanliurfa Education And Research Hospital, Sanliurfa, Turkey
| | - Abdulrahim Dundar
- Department of Orthopaedics and Traumatology, Faculty of Medicine, Hitit University, Corum, Turkey
| | - Zulkuf Akdemir
- Department of Radiology, Faculty of Medicine, Van Yuzuncu Yil University, Van, Turkey
| | - Mehmet Ata Gokalp
- Department of Orthopaedics and Traumatology, Faculty of Medicine, Van Yuzuncu Yil University, Van, Turkey
| |
Collapse
|
2
|
Sakti M, Wawolumaja AFI, Saleh R, Usman MA, Arifin J, Johan MP. Modified Implant Fixation Technique Is an Alternative for Patients with an Anterior Cruciate Ligament Tear in Limited Resource Settings: A Comparison Functional Outcome Study with Polyether Ether Ketone and Bioabsorbable Screws. J Clin Med 2024; 13:2964. [PMID: 38792505 PMCID: PMC11121912 DOI: 10.3390/jcm13102964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 05/08/2024] [Accepted: 05/16/2024] [Indexed: 05/26/2024] Open
Abstract
Background: Anterior cruciate ligament (ACL) injury is one of the most prevalent factors contributing to knee instability worldwide. This study aimed to evaluate modified metal fixation techniques for ACL reconstruction compared to factory-made implants, such as polyether ether ketone (PEEK) screws, bioabsorbable screws, and modified metal implants. Methods: A retrospective cohort analysis was conducted to assess the functional outcomes of ACL using various fixation methods. Patients who underwent arthroscopic ACL reconstruction at several healthcare facilities were included in the study. The functional outcomes were evaluated using the Lysholm Knee Scoring Scale and the International Knee Documentation Committee (IKDC) score questionnaire at 6- and 12 months post-surgery. Statistical analyses, including the Shapiro-Wilk test and analysis of variance, were performed to compare outcomes among the fixation groups. Results: Thirty-three patients who underwent ACL reconstruction surgery with varying distributions across the three fixation groups (modified metal implants, PEEK screws, and bioabsorbable screws) were included in the study. As measured by the Lysholm and IKDC scores at 6- and 12 months post-surgery, the PEEK group demonstrated the highest average scores. Nevertheless, these functional outcomes were not significantly different between the groups (p = 0.140, 0.770, 0.150, and 0.200). These findings align with those of meta-analyses comparing different fixation methods for ACL reconstruction. Conclusions: While acknowledging the small sample size as a limitation, this study suggests that modified metal implants represent viable options for ACL reconstruction. The selection of fixation methods should consider patient characteristics and preferences, emphasizing biomechanical stability and long-term outcomes. Further research is needed to validate these findings and explore their biomechanical properties and cost-effectiveness.
Collapse
Affiliation(s)
- Muhammad Sakti
- Department of Orthopedic & Traumatology, Faculty of Medicine, Hasanuddin University, Makassar 90245, Indonesia; (A.F.I.W.); (R.S.); (M.A.U.); (J.A.); (M.P.J.)
- Department of Orthopedic & Traumatology, Wahidin Sudirohusodo Hospital, Makassar 90245, Indonesia
| | - Arian Fardin Ignatius Wawolumaja
- Department of Orthopedic & Traumatology, Faculty of Medicine, Hasanuddin University, Makassar 90245, Indonesia; (A.F.I.W.); (R.S.); (M.A.U.); (J.A.); (M.P.J.)
| | - Ruksal Saleh
- Department of Orthopedic & Traumatology, Faculty of Medicine, Hasanuddin University, Makassar 90245, Indonesia; (A.F.I.W.); (R.S.); (M.A.U.); (J.A.); (M.P.J.)
- Department of Orthopedic & Traumatology, Wahidin Sudirohusodo Hospital, Makassar 90245, Indonesia
| | - Muhammad Andry Usman
- Department of Orthopedic & Traumatology, Faculty of Medicine, Hasanuddin University, Makassar 90245, Indonesia; (A.F.I.W.); (R.S.); (M.A.U.); (J.A.); (M.P.J.)
- Department of Orthopedic & Traumatology, Wahidin Sudirohusodo Hospital, Makassar 90245, Indonesia
| | - Jainal Arifin
- Department of Orthopedic & Traumatology, Faculty of Medicine, Hasanuddin University, Makassar 90245, Indonesia; (A.F.I.W.); (R.S.); (M.A.U.); (J.A.); (M.P.J.)
- Department of Orthopedic & Traumatology, Wahidin Sudirohusodo Hospital, Makassar 90245, Indonesia
| | - Muhammad Phetrus Johan
- Department of Orthopedic & Traumatology, Faculty of Medicine, Hasanuddin University, Makassar 90245, Indonesia; (A.F.I.W.); (R.S.); (M.A.U.); (J.A.); (M.P.J.)
- Department of Orthopedic & Traumatology, Wahidin Sudirohusodo Hospital, Makassar 90245, Indonesia
| |
Collapse
|
3
|
Yuan W, Qi W, Hu T, Zhang J, An MY, Zhao G, Wang XP, Li C, Liu Y. Outcomes of RigidFix Cross Pin Fixation in Femoral and Tibial Tunnel for Anterior Cruciate Ligament Reconstruction. Orthop Surg 2024; 16:337-345. [PMID: 38088239 PMCID: PMC10834228 DOI: 10.1111/os.13934] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 10/08/2023] [Accepted: 10/09/2023] [Indexed: 02/03/2024] Open
Abstract
OBJECTIVES There is no clear consensus so far on which fixation method is most favorable for the tibial tunnel in anterior cruciate ligament reconstruction (ACLR). The purpose of this paper is to investigate the outcome of RigidFix cross pins fixation in the tibial tunnel and to explore the advantages of RigidFix applied both in the femoral and tibial tunnel with hamstring tendon graft in anterior cruciate ligament reconstruction. METHODS This retrospective study included 53 patients (male/female, 45/8) who underwent anterior cruciate ligament reconstruction using autologous hamstring tendons between January 2013 and December 2017 at our institute. The participants in group A (n = 36) received anterior cruciate ligament reconstruction with RigidFix cross pins fixation in both femoral and tibial tunnels, while those in group B (n = 17) with RigidFix cross pins fixation in the femoral tunnel and Interference screw fixation in the tibial tunnel. The visual analogue scale (VAS) score, International Knee Documentation Committee subjective knee form 2000 (IKDC2000) score, Lysholm knee scoring scale, Tegner activity score and the side-to-side difference were compared at 2 and 5 years postoperatively. The graft diameter, number of strands in graft and the average diameter of each strand were also compared between the two groups. The categorical parameters were analyzed by chi-square test and the continuous variables conforming to a normal distribution were analyzed by Student's t-test. RESULTS At 2 years postoperation, the VAS score (1.61 ± 0.55), side-to-side difference (1.50 ± 0.58) in group A were significantly lower than that in group B, and the IKDC2000 score (88.81 ± 3.88), Tegner activity score (6.14 ± 0.60) in group A were significantly higher than that in group B. At 5 years postoperation, the VAS score (1.64 ± 0.68), side-to-side difference (1.73 ± 0.63) in group A were significantly lower than that in group B, and the IKDC2000 score (89.09 ± 3.85), Tegner activity score (6.58 ± 0.94) in group A were slso significantly higher than that in group B. There was statistical difference in the change of the side-to-side difference between the two groups (group A vs. B, 0.22 ± 0.08 vs. 0.34 ± 0.11, p < 0.001). There were also statistical differences in the graft diameter (group A vs. B, 7.83 ± 0.74 vs. 7.41 ± 0.51, p = 0,038), number of strands in graft (5.67 ± 0.72 vs. 4.00 ± 0.00, p < 0.001) and the average diameter of each strand (1.41 ± 0.22 vs. 1.85 ± 0.13, p < 0.001) between the two groups. CONCLUSION RigidFix cross pins fixation in the tibial tunnel for anterior cruciate ligament reconstruction can achieve better 5-year results when compared with the interference screw, and the hamstring tendon can be folded into a thicker graft when RigidFix cross pins were applied in both femoral and tibial tunnels.
Collapse
Affiliation(s)
- Wei Yuan
- Medical School of Chinese PLA, Beijing, China
- Department of Orthopedics, The First Medical Center, Chinese PLA General Hospital, Beijing, China
- Department of Orthopedics, PLA Strategic Support Force Characteristic Medical Center, Beijing, China
| | - Wei Qi
- Department of Orthopedics, The First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Tingting Hu
- The Sixth Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Jia Zhang
- Medical School of Chinese PLA, Beijing, China
| | | | - Gang Zhao
- Medical School of Chinese PLA, Beijing, China
| | - Xiao-Ping Wang
- Department of Orthopedics, PLA Strategic Support Force Characteristic Medical Center, Beijing, China
| | - Chunbao Li
- Department of Orthopedics, The First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Yujie Liu
- Department of Orthopedics, The First Medical Center, Chinese PLA General Hospital, Beijing, China
| |
Collapse
|
4
|
Runer A, Hax J, Gelber P, Stadelmann VA, Preiss S, Salzmann G. Triple Hybrid Tibial Anterior Cruciate Ligament Graft Fixation. Arthrosc Tech 2023; 12:e2375-e2379. [PMID: 38196858 PMCID: PMC10773257 DOI: 10.1016/j.eats.2023.08.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2023] [Accepted: 08/13/2023] [Indexed: 01/11/2024] Open
Abstract
Optimal graft fixation in anterior cruciate ligament reconstruction is critical. Several direct and indirect methods of graft fixation exist, each with advantages and disadvantages. This Technical Note describes a tibial hybrid anterior cruciate ligament graft fixation technique combining direct and indirect fixation methods, including autologous bone augmentation of the drill tunnel using cancellous bone fragments.
Collapse
Affiliation(s)
- Armin Runer
- Department of Sports Orthopaedics, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Jakob Hax
- Departments of Hip and Knee Surgery, Schulthess Klinik, Zürich, Switzerland
| | - Pablo Gelber
- Department of Orthopaedic Surgery, Hospital de la Santa Creu i Sant Pau, Universitat Autonoma de Barcelona, Barcelona, Spain
| | | | - Stefan Preiss
- Departments of Hip and Knee Surgery, Schulthess Klinik, Zürich, Switzerland
| | - Gian Salzmann
- Departments of Hip and Knee Surgery, Schulthess Klinik, Zürich, Switzerland
| |
Collapse
|
5
|
Runer A, Keeling L, Wagala N, Nugraha H, Özbek EA, Hughes JD, Musahl V. Current trends in graft choice for anterior cruciate ligament reconstruction - part I: anatomy, biomechanics, graft incorporation and fixation. J Exp Orthop 2023; 10:37. [PMID: 37005974 PMCID: PMC10067784 DOI: 10.1186/s40634-023-00600-4] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Accepted: 03/22/2023] [Indexed: 04/04/2023] Open
Abstract
Graft selection in anterior cruciate ligament (ACL) reconstruction is critical, as it remains one of the most easily adjustable factors affecting graft rupture and reoperation rates. Commonly used autografts, including hamstring tendon, quadriceps tendon and bone-patellar-tendon-bone, are reported to be biomechanically equivalent or superior compared to the native ACL. Despite this, such grafts are unable to perfectly replicate the complex anatomical and histological characteristics of the native ACL. While there remains inconclusive evidence as to the superiority of one autograft in terms of graft incorporation and maturity, allografts appear to demonstrate slower incorporation and maturity compared to autografts. Graft fixation also affects graft properties and subsequent outcomes, with each technique having unique advantages and disadvantages that should be carefully considered during graft selection.
Collapse
Affiliation(s)
- Armin Runer
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, University of Pittsburgh, Pittsburgh, PA, USA.
- Department for Sports Orthopaedics, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany.
| | - Laura Keeling
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, University of Pittsburgh, Pittsburgh, PA, USA
| | - Nyaluma Wagala
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, University of Pittsburgh, Pittsburgh, PA, USA
| | - Hans Nugraha
- Department of Orthopaedic and Traumatology, Faculty of Medicine, University of Udayana, / Prof. Dr. I.G.N.G. Ngoerah General Hospital, Denpasar, Bali, Indonesia
| | - Emre Anil Özbek
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, University of Pittsburgh, Pittsburgh, PA, USA
- Department of Orthopedics and Traumatology, Ankara University, Ankara, Turkey
| | - Jonathan D Hughes
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, University of Pittsburgh, Pittsburgh, PA, USA
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Volker Musahl
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, University of Pittsburgh, Pittsburgh, PA, USA
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| |
Collapse
|