1
|
Guerra LL, Faccinetti NI, Trabucchi A, Rovitto BD, Sabljic AV, Poskus E, Iacono RF, Valdez SN. Novel prokaryotic expression of thioredoxin-fused insulinoma associated protein tyrosine phosphatase 2 (IA-2), its characterization and immunodiagnostic application. BMC Biotechnol 2016; 16:84. [PMID: 27881117 PMCID: PMC5122161 DOI: 10.1186/s12896-016-0309-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2016] [Accepted: 10/21/2016] [Indexed: 11/11/2022] Open
Abstract
Background The insulinoma associated protein tyrosine phosphatase 2 (IA-2) is one of the immunodominant autoantigens involved in the autoimmune attack to the beta-cell in Type 1 Diabetes Mellitus. In this work we have developed a complete and original process for the production and recovery of the properly folded intracellular domain of IA-2 fused to thioredoxin (TrxIA-2ic) in Escherichia coli GI698 and GI724 strains. We have also carried out the biochemical and immunochemical characterization of TrxIA-2icand design variants of non-radiometric immunoassays for the efficient detection of IA-2 autoantibodies (IA-2A). Results The main findings can be summarized in the following statements: i) TrxIA-2ic expression after 3 h of induction on GI724 strain yielded ≈ 10 mg of highly pure TrxIA-2ic/L of culture medium by a single step purification by affinity chromatography, ii) the molecular weight of TrxIA-2ic (55,358 Da) could be estimated by SDS-PAGE, size exclusion chromatography and mass spectrometry, iii) TrxIA-2ic was properly identified by western blot and mass spectrometric analysis of proteolytic digestions (63.25 % total coverage), iv) excellent immunochemical behavior of properly folded full TrxIA-2ic was legitimized by inhibition or displacement of [35S]IA-2 binding from IA-2A present in Argentinian Type 1 Diabetic patients, v) great stability over time was found under proper storage conditions and vi) low cost and environmentally harmless ELISA methods for IA-2A assessment were developed, with colorimetric or chemiluminescent detection. Conclusions E. coli GI724 strain emerged as a handy source of recombinant IA-2ic, achieving high levels of expression as a thioredoxin fusion protein, adequately validated and applicable to the development of innovative and cost-effective immunoassays for IA-2A detection in most laboratories. Electronic supplementary material The online version of this article (doi:10.1186/s12896-016-0309-2) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Luciano Lucas Guerra
- Universidad de Buenos Aires, Consejo Nacional de Investigaciones Científicas y Técnicas, Instituto de Estudios de la Inmunidad Humoral "Prof. Ricardo A. Margni" (IDEHU), Facultad de Farmacia y Bioquímica, Buenos Aires, Argentina
| | - Natalia Inés Faccinetti
- Universidad de Buenos Aires, Consejo Nacional de Investigaciones Científicas y Técnicas, Instituto de Estudios de la Inmunidad Humoral "Prof. Ricardo A. Margni" (IDEHU), Facultad de Farmacia y Bioquímica, Buenos Aires, Argentina
| | - Aldana Trabucchi
- Universidad de Buenos Aires, Consejo Nacional de Investigaciones Científicas y Técnicas, Instituto de Estudios de la Inmunidad Humoral "Prof. Ricardo A. Margni" (IDEHU), Facultad de Farmacia y Bioquímica, Buenos Aires, Argentina
| | - Bruno David Rovitto
- Universidad de Buenos Aires, Consejo Nacional de Investigaciones Científicas y Técnicas, Instituto de Estudios de la Inmunidad Humoral "Prof. Ricardo A. Margni" (IDEHU), Facultad de Farmacia y Bioquímica, Buenos Aires, Argentina
| | - Adriana Victoria Sabljic
- Universidad de Buenos Aires, Consejo Nacional de Investigaciones Científicas y Técnicas, Instituto de Estudios de la Inmunidad Humoral "Prof. Ricardo A. Margni" (IDEHU), Facultad de Farmacia y Bioquímica, Buenos Aires, Argentina
| | - Edgardo Poskus
- Universidad de Buenos Aires, Consejo Nacional de Investigaciones Científicas y Técnicas, Instituto de Estudios de la Inmunidad Humoral "Prof. Ricardo A. Margni" (IDEHU), Facultad de Farmacia y Bioquímica, Buenos Aires, Argentina
| | - Ruben Francisco Iacono
- Universidad de Buenos Aires, Consejo Nacional de Investigaciones Científicas y Técnicas, Instituto de Estudios de la Inmunidad Humoral "Prof. Ricardo A. Margni" (IDEHU), Facultad de Farmacia y Bioquímica, Buenos Aires, Argentina
| | - Silvina Noemí Valdez
- Universidad de Buenos Aires, Consejo Nacional de Investigaciones Científicas y Técnicas, Instituto de Estudios de la Inmunidad Humoral "Prof. Ricardo A. Margni" (IDEHU), Facultad de Farmacia y Bioquímica, Buenos Aires, Argentina.
| |
Collapse
|
2
|
A rapid lateral flow immunoassay for the detection of tyrosine phosphatase-like protein IA-2 autoantibodies in human serum. PLoS One 2014; 9:e103088. [PMID: 25047039 PMCID: PMC4105419 DOI: 10.1371/journal.pone.0103088] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2014] [Accepted: 06/27/2014] [Indexed: 12/20/2022] Open
Abstract
Type 1 diabetes (T1D) results from the destruction of pancreatic insulin-producing beta cells and is strongly associated with the presence of islet autoantibodies. Autoantibodies to tyrosine phosphatase-like protein IA-2 (IA-2As) are considered to be highly predictive markers of T1D. We developed a novel lateral flow immunoassay (LFIA) based on a bridging format for the rapid detection of IA-2As in human serum samples. In this assay, one site of the IA-2As is bound to HA-tagged-IA-2, which is subsequently captured on the anti-HA-Tag antibody-coated test line on the strip. The other site of the IA-2As is bound to biotinylated IA-2, allowing the complex to be visualized using colloidal gold nanoparticle-conjugated streptavidin. For this study, 35 serum samples from T1D patients and 44 control sera from non-diabetic individuals were analyzed with our novel assay and the results were correlated with two IA-2A ELISAs. Among the 35 serum samples from T1D patients, the IA-2A LFIA, the in-house IA-2A ELISA and the commercial IA-2A ELISA identified as positive 21, 29 and 30 IA-2A-positive sera, respectively. The major advantages of the IA-2A LFIA are its rapidity and simplicity.
Collapse
|
3
|
Amghouz Z, García-Granda S, García JR, Ferreira RAS, Mafra L, Carlos LD, Rocha J. Series of Metal Organic Frameworks Assembled from Ln(III), Na(I), and Chiral Flexible-Achiral Rigid Dicarboxylates Exhibiting Tunable UV–vis–IR Light Emission. Inorg Chem 2011; 51:1703-16. [DOI: 10.1021/ic202020z] [Citation(s) in RCA: 60] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Zakariae Amghouz
- Departamentos de Química Física
y Analítica
y Química Orgánica e Inorgánica, Universidad de Oviedo, 33006 Oviedo-CINN, Spain
| | - Santiago García-Granda
- Departamentos de Química Física
y Analítica
y Química Orgánica e Inorgánica, Universidad de Oviedo, 33006 Oviedo-CINN, Spain
| | - José R. García
- Departamentos de Química Física
y Analítica
y Química Orgánica e Inorgánica, Universidad de Oviedo, 33006 Oviedo-CINN, Spain
| | - Rute A. S. Ferreira
- Departments of Chemistry & Physics, CICECO, University of Aveiro, 3810-193 Aveiro, Portugal
| | - Luís Mafra
- Departments of Chemistry & Physics, CICECO, University of Aveiro, 3810-193 Aveiro, Portugal
| | - Luis D. Carlos
- Departments of Chemistry & Physics, CICECO, University of Aveiro, 3810-193 Aveiro, Portugal
| | - João Rocha
- Departments of Chemistry & Physics, CICECO, University of Aveiro, 3810-193 Aveiro, Portugal
| |
Collapse
|
4
|
Babaya N, Liu E, Miao D, Li M, Yu L, Eisenbarth GS. Murine high specificity/sensitivity competitive europium insulin autoantibody assay. Diabetes Technol Ther 2009; 11:227-33. [PMID: 19344197 PMCID: PMC2903340 DOI: 10.1089/dia.2008.0072] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
BACKGROUND Most insulin autoantibody assays for both human and animal models are in a radioassay format utilizing (125)I-insulin, but despite the radioassay format international workshops have documented difficulty in standardization between laboratories. There is thus a need for simpler assay formats that do not utilize radioactivity, yet retain the high specificity and sensitivity of radioassays. METHODS To establish an easier enzyme-linked immunosorbent assay (ELISA) for insulin autoantibodies of non-obese diabetic (NOD) mice, we used an ELISA format, competition with unlabeled insulin, europium-avidin, and time-resolved fluorescence detection (competitive europium insulin autoantibody assay). RESULTS The competitive europium assay of insulin autoantibodies when applied to sera from NOD mice had high sensitivity and specificity (92% sensitivity, 100% specificity) compared to our standard insulin autoantibody radioassay (72% sensitivity, 100% specificity) in analyzing blind workshop sera. It is noteworthy that though the assay has extremely high sensitivity for murine insulin autoantibodies and utilizes human insulin as target autoantigen, human sera with high levels of insulin autoantibodies are not detected. CONCLUSIONS Our results clearly indicate that low levels of insulin autoantibodies can be detected in an ELISA-like format. Combining a europium-based ELISA with competition with fluid-phase autoantigen can be applicable to many autoantigens to achieve high specificity and sensitivity in an ELISA format.
Collapse
Affiliation(s)
- Naru Babaya
- Barbara Davis Center for Childhood Diabetes, University of Colorado Health Sciences Center , Aurora, Colorado 80045-6511, USA
| | | | | | | | | | | |
Collapse
|
5
|
Burbelo PD, Hirai H, Leahy H, Lernmark A, Ivarsson SA, Iadarola MJ, Notkins AL. A new luminescence assay for autoantibodies to mammalian cell-prepared insulinoma-associated protein 2. Diabetes Care 2008; 31:1824-6. [PMID: 18535195 PMCID: PMC2518352 DOI: 10.2337/dc08-0286] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
OBJECTIVE Insulinoma-associated protein 2 (IA-2) is a major autoantigen in type 1 diabetes, and IA-2 autoantibodies are routinely detected by a liquid-phase radioimmunoprecipitation assay. The present experiments were initiated to develop a new assay that does not require the use of radioisotopes or autoantigens prepared in bacteria or by in vitro transcription/translation. RESEARCH DESIGN AND METHODS IA-2 luciferase fusion protein was expressed in mammalian cells and assayed for autoantibodies by liquid-phase luciferase immunoprecipitation. RESULTS Our study showed that there was no significant difference between the luciferase immunoprecipitation and the radioimmunoprecipitation assays in sensitivity and specificity, and comparison of the two assays revealed a high correlation coefficient (R(2) = 0.805). CONCLUSIONS The luciferase system offers a robust, inexpensive, nonradioactive method for the detection of autoantibodies to mammalian cell-prepared IA-2 and could be of practical value at the clinical level.
Collapse
Affiliation(s)
- Peter D Burbelo
- Sensory Biology Branch, National Institute of Dental and Craniofacial Research, National Institutes of Health, Bethesda, Maryland, USA
| | | | | | | | | | | | | |
Collapse
|
6
|
Ayela C, Roquet F, Valera L, Granier C, Nicu L, Pugnière M. Antibody–antigenic peptide interactions monitored by SPR and QCM-D. Biosens Bioelectron 2007; 22:3113-9. [PMID: 17349782 DOI: 10.1016/j.bios.2007.01.020] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2006] [Revised: 01/15/2007] [Accepted: 01/24/2007] [Indexed: 11/21/2022]
Abstract
This work reports on a complementary use of surface plasmon resonance (SPR) and quartz crystal microbalance with dissipation monitoring (QCM-D) technologies to study interactions between a peptide antigen and polyclonal antibodies, in an experimental format suitable for diagnostic assays of autoimmune diseases. In the chosen model, a synthetic peptide from the juxtamembrane region of IA-2 (a type 1 diabetes associated antigen) was immobilized by an optimized chemical protocol applicable to both BIACORE and QCM-D sensors. A thorough study of the peptide immobilization was performed to optimize the signal-to-noise ratio using mixed self-assembled monolayers (SAM) on a gold surface. Introduction of polyethylene glycol (EG(6)) chains into mixed SAM layers and addition of an anionic surfactant to the human serum reduced non-specific binding without modifying the viscoelasticity properties of the layer. Under our conditions, the antibody SPR detection limit was determined to be 0.2 nM in diluted human serum. This value is in agreement with the reported rank distribution of IA-2 antibodies in diabetic patient sera. Label-free and real-time technologies such as SPR and/or QCM-D could be precious tools in future diagnostic assays.
Collapse
Affiliation(s)
- Cedric Ayela
- CNRS UPR 800, Laboratoire d'Analyse et Architecture des Systèmes, 7 Avenue du Colonel Roche, Toulouse, France
| | | | | | | | | | | |
Collapse
|
7
|
Westerlund A, Ankelo M, Simell S, Ilonen J, Knip M, Simell O, Hinkkanen AE. Affinity maturation of immunoglobulin A anti-tissue transglutaminase autoantibodies during development of coeliac disease. Clin Exp Immunol 2007; 148:230-40. [PMID: 17286799 PMCID: PMC1868886 DOI: 10.1111/j.1365-2249.2007.03336.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
Coeliac disease (CD) is an immune-mediated enteropathy triggered by ingestion of wheat gluten and related cereals in genetically predisposed individuals. Circulating immunoglobulin A (IgA) class autoantibodies against tissue transglutaminase (IgA-TGA) are highly specific and sensitive serological markers for CD, which is ultimately confirmed by duodenal biopsy. Although CD is considered a life-long disorder, transient or fluctuating IgA-TGA seropositivity has been observed in asymptomatic individuals on a gluten-containing diet. We set out to explore possible differences in the maturation of IgA-TGA avidity between individuals progressing to CD and subjects remaining healthy despite occasional expression of autoantibodies. We developed a time-resolved fluorometric IgA-TGA assay based on human recombinant tissue transglutaminase (tTG), and further modified the method to also measure urea-dependent avidity of the autoantibodies. We measured the autoantibody titres and avidities of sequential serum samples from 10 children developing CD and 10 children presenting transient or fluctuating autoantibodies. Both the initial titres at seroconversion and peak values of transient/fluctuating IgA-TGA were significantly lower than corresponding autoantibody titres in samples drawn from individuals with progressing CD (P = 0.004 and P = 0.0002, respectively). However, there were no statistically significant differences in the initial or peak avidity index values between the two groups of children. The avidity index values increased during the follow-up period (P = 0.013 for both groups) with no significant difference in the rate of avidity maturation between children with transient/fluctuating IgA-TGA and children developing CD. According to our results, high autoantibody titres have a higher predictive value than avidity maturation of TGA-IgA in screening for CD.
Collapse
Affiliation(s)
- A Westerlund
- Department of Biochemistry and Pharmacy, Abo Akademi University, Turku, Finland
| | | | | | | | | | | | | |
Collapse
|
8
|
Ankelo M, Westerlund A, Blomberg K, Knip M, Ilonen J, Hinkkanen AE. Time-resolved immunofluorometric dual-label assay for simultaneous detection of autoantibodies to GAD65 and IA-2 in children with type 1 diabetes. Clin Chem 2007; 53:472-9. [PMID: 17259239 DOI: 10.1373/clinchem.2005.064568] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Autoantibodies to glutamic acid decarboxylase (GADAs), specifically the 65-kDa isoform GAD65, and autoantibodies to the protein tyrosine phosphatase-like molecule IA-2 (IA-2As) predict development of diabetes. Our aim was to develop a time-resolved immunofluorometric (TR-IFMA) dual-label assay method for the simultaneous detection of these autoantibodies and to evaluate the diagnostic sensitivity of the method compared with single-label TR-IFMA and fluid-phase radiobinding assay (RBA) in screening children with type 1 diabetes. METHODS We incubated combined biotinylated GAD65 and IA-2 proteins, glutathione S-transferase (GST)-IA-2, europium-labeled GAD65, terbium-labeled anti-GST antibody, and serum sample or calibrator and transferred aliquots to a streptavidin-coated 96-well microtiter plate for a second incubation. After washing, we added Delfia Enhancement solution to each well and measured the fluorescence of Eu. We developed the Tb fluorescence signal by use of the Delfia Enhancer solution and measured it. We analyzed serum samples from a cohort of 100 children with newly diagnosed type 1 diabetes. RESULTS The correlation coefficients between the autoantibody concentrations measured by dual- and single-label TR-IFMA assays were 0.962 for GADA and 0.874 for IA-2A. Among 100 children with newly diagnosed diabetes, 65 of them were GADA positive in the dual-label assay, 64 in the single-label assay, and 66 in the RBA GADA assay. Seventy-four of the children tested positive for IA-2A in both TR-IFMA assay types, and 79 in the RBA IA-2A assay. CONCLUSIONS The novel dual-label immunofluorometric assay performed comparably to the separate, single-label GADA and IA-2A assays in screening for beta-cell autoimmunity in children with newly diagnosed type 1 diabetes.
Collapse
Affiliation(s)
- Matti Ankelo
- JDRF Center for Prevention of Type 1 Diabetes in Finland.
| | | | | | | | | | | |
Collapse
|
9
|
Hemmilä I, Laitala V. Progress in Lanthanides as Luminescent Probes. J Fluoresc 2005; 15:529-42. [PMID: 16167211 DOI: 10.1007/s10895-005-2826-6] [Citation(s) in RCA: 333] [Impact Index Per Article: 17.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2004] [Accepted: 03/01/2005] [Indexed: 12/20/2022]
Abstract
Lanthanides have recently found applications in different fields of biomolecular and medical research. Luminescent lanthanide chelates have created interest mainly due to their unique luminescent properties, such as their long Stokes' shift and exceptional decay times allowing efficient temporal discrimination of background interferences in the assays, such as immunoassays. Recently, new organometallic complexes have been developed giving opportunities to novel applications, in heterogeneous and homogeneous immunoassays, DNA hybridization assays, high-throughput screening as well as in imaging. In addition, encapsulating the chelates into suitable matrix in beads enables the use of new members of lanthanides extending the emission wavelength to micrometer range and decays from a few microseconds to milliseconds. As the luminescence is derived from complicated intra-chelate energy transfer, it also gives novel opportunities to exploit these levels in different types of energy transfer based applications. This review gives a short overview of recent development of lanthanide chelate-labels and discusses in more details of energy levels and their exploitation in new assay formats.
Collapse
Affiliation(s)
- I Hemmilä
- Perkin Elmer Life and Analytical Sciences, Wallac Oy, P.O. Box 10, FIN-20101, Turku, Finland.
| | | |
Collapse
|
10
|
Westerlund A, Ankelo M, Ilonen J, Knip M, Simell O, Hinkkanen AE. Absence of avidity maturation of autoantibodies to the protein tyrosine phosphatase-like IA-2 molecule and glutamic acid decarboxylase (GAD65) during progression to type 1 diabetes. J Autoimmun 2005; 24:153-67. [PMID: 15829408 DOI: 10.1016/j.jaut.2004.12.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2004] [Revised: 12/14/2004] [Accepted: 12/17/2004] [Indexed: 11/27/2022]
Abstract
Immunoglobulin G avidity assays are used to distinguish between the acute and chronic phase of several infectious diseases, and there is evidence of autoantibody affinity maturation also in autoimmune diseases. To assess whether the analysis of the avidity of autoantibodies against the protein tyrosine phosphatase-like IA-2 molecule and glutamic acid decarboxylase (GAD65) could improve the accuracy of risk assessment of progression to clinical type 1 diabetes, we established methods for the determination of the autoantibody avidity based on our previously developed time-resolved fluorometric IA-2 and GAD65 autoantibody (IA-2A and GADA) assays. The avidity indices of sequential plasma samples from six IA-2A-positive and seven GADA-positive prediabetic children were analysed applying elution with urea and diethylamine (DEA). For comparison, corresponding avidity indices of control children, who have remained non-diabetic for at least 3 years after seroconversion to IA-2A and GADA positivity, were analysed. For most of the children, only a slight fluctuation in the avidity index values was observed over time, although the titres for IA-2A and GADA varied substantially in some cases. The avidity indices of the prediabetic children remained within the same range as those of the control group throughout the follow-up. Our results indicate that the analysis of the avidity index levels of IA-2A and GADA does not improve the accuracy of the prediction of type 1 diabetes based on autoantibody detection.
Collapse
Affiliation(s)
- Annette Westerlund
- Department of Biochemistry and Pharmacy, Abo Akademi University, Tykistökatu 6, FIN-20520 Turku, Finland.
| | | | | | | | | | | |
Collapse
|
11
|
Palomer X, Mauricio D, Rodríguez-Espinosa J, Zapico E, Mayoral C, González-Sastre F, de Leiva A, Blanco-Vaca F. Evaluation of Two Nonisotopic Immunoassays for Determination of Glutamic Acid Decarboxylase and Tyrosine Phosphatase Autoantibodies in Serum. Clin Chem 2004; 50:1378-82. [PMID: 15155543 DOI: 10.1373/clinchem.2004.031799] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Abstract
Background: Autoantibodies for the 65-kDa form of glutamic acid decarboxylase (GAD65) and protein tyrosine phosphatase-like protein (IA-2) are measured for risk prediction and diagnosis of autoimmune diabetes mellitus. There is a lack of adequate nonisotopic alternatives to the most widely used method for both autoantibodies, which is a radiobinding assay (RBA).
Methods: We compared two commercially available immunoassays, an ELISA and a time-resolved immunofluorometric assay (TR-IFMA), with RBA.
Results: We found excellent agreement between the RBA and ELISA for measurement of GAD65 autoantibodies (GADAs); they showed comparable analytical precision in the cutoff range and achieved similar diagnostic specificity. The ELISA identified more GADA-positive individuals among patients with new-onset type 1 diabetes than did the RBA [89% (95% confidence interval, 78–95%), vs 71% (58–82%); P <0.03]. For IA-2 autoantibodies (IA-2As), only the TR-IFMA achieved analytical performance and diagnostic accuracy comparable to that of the RBA. These results with the GADA ELISA and IA-2A TR-IFMA were consistent with those obtained blindly in the Diabetes Antibody Standardization Program 2003. The performance of the GADA TR-IFMA and IA-2A ELISA was unsatisfactory, and these tests were not subjected to clinical evaluation.
Conclusions: The GADA ELISA and IA-2A TR-IFMA behave comparably with RBA and are thus suitable for use in the clinical laboratory.
Collapse
Affiliation(s)
- Xavier Palomer
- Institut de Recerca, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain
| | | | | | | | | | | | | | | |
Collapse
|