1
|
Okwundu CI, Bhutani VK, Uthman OA, Smith J, Olowoyeye A, Fiander M, Wiysonge CS. Transcutaneous bilirubinometry for detecting jaundice in term or late preterm neonates. Cochrane Database Syst Rev 2024; 5:CD011060. [PMID: 38804265 PMCID: PMC11131145 DOI: 10.1002/14651858.cd011060.pub2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/29/2024]
Abstract
BACKGROUND The American Academy of Pediatrics and the Canadian Paediatric Society both advise that all newborns should undergo bilirubin screening before leaving the hospital, and this has become the standard practice in both countries. However, the US Preventive Task Force has found no strong evidence to suggest that this practice of universal screening for bilirubin reduces the occurrence of significant outcomes such as bilirubin-induced neurologic dysfunction or kernicterus. OBJECTIVES To evaluate the effectiveness of transcutaneous screening compared to visual inspection for hyperbilirubinemia to prevent the readmission of newborns (infants greater than 35 weeks' gestation) for phototherapy. SEARCH METHODS We searched CENTRAL, MEDLINE, Embase, CINAHL, ClinicalTrials.gov, ICTRP, and ISRCTN in June 2023. We also searched conference proceedings, and the reference lists of included studies. SELECTION CRITERIA We included randomized controlled trials (RCTs), quasi-randomized, cluster-randomized, or prospective cohort studies with control arm that evaluated the use of transcutaneous bilirubin (TcB) screening for hyperbilirubinemia in newborns before hospital discharge. DATA COLLECTION AND ANALYSIS We used standard methodologic procedures expected by Cochrane. We evaluated treatment effects using a fixed-effect model with risk ratio (RR) and 95% confidence intervals (CI) for categorical data and mean, standard deviation (SD), and mean difference (MD) for continuous data. We used the GRADE approach to evaluate the certainty of evidence. MAIN RESULTS We identified one RCT (1858 participants) that met our inclusion criteria. The study included 1858 African newborns at 35 weeks' gestation or greater who were receiving routine care at a well-baby nursery, and were randomly recruited prior to discharge to undergo TcB screening. The study had good methodologic quality. TcB screening versus visual assessment of hyperbilirubinemia in newborns: - may reduce readmission to the hospital for hyperbilirubinemia (RR 0.25, 95% CI 0.14 to 0.46; P < 0.0001; moderate-certainty evidence); - probably has little or no effect on the rate of exchange transfusion (RR 0.20, 95% CI 0.01 to 14.16; low-certainty evidence); - may increase the number of newborns who require phototherapy prior to discharge (RR 2.67, 95% CI 1.56 to 4.55; moderate-certainty evidence). - probably has little or no effect on the rate of acute bilirubin encephalopathy (RR 0.33, 95% CI 0.01 to 8.18; low-certainty evidence). The study did not evaluate or report cost of care. AUTHORS' CONCLUSIONS Moderate-certainty evidence suggests that TcB screening may reduce readmission for hyperbilirubinemia compared to visual inspection. Low-certainty evidence also suggests that TcB screening probably has little or no effect on the rate of exchange transfusion compared to visual inspection. However, moderate-certainty evidence suggests that TcB screening may increase the number of newborns that require phototherapy before discharge compared to visual inspection. Low-certainty evidence suggests that TcB screening probably has little or no effect on the rate of acute bilirubin encephalopathy compared to visual inspection. Given that we have only identified one RCT, further studies are necessary to determine whether TcB screening can help to reduce readmission and complications related to neonatal hyperbilirubinemia. In settings with limited newborn follow-up after hospital discharge, identifying newborns at risk of severe hyperbilirubinemia before hospital discharge will be important to plan targeted follow-up of these infants.
Collapse
Affiliation(s)
- Charles I Okwundu
- Centre for Evidence-based Health Care, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa
| | - Vinod K Bhutani
- Division of Neonatal and Developmental Medicine, Department of Pediatrics, Stanford School of Medicine, Lucile Packard Children's Hospital, Palo Alto, California, USA
| | - Olalekan A Uthman
- Warwick Centre for Applied Health Research and Delivery (WCAHRD), Division of Health Sciences, Warwick Medical School, The University of Warwick, Coventry, UK
| | - Johan Smith
- Department of Paediatrics and Child Health, Stellenbosch University, Faculty of Health Sciences, Stellenbosch, South Africa
| | - Abiola Olowoyeye
- Phoenix Children's Hospital and University of Arizona College of Medicine, Phoenix, Arizona, USA
| | | | - Charles S Wiysonge
- Cochrane South Africa, South African Medical Research Council, Cape Town, South Africa
| |
Collapse
|
2
|
Yan Q, Gong Y, Luo Q, Yin X, Yang L, Wang H, Feng J, Xing K, Huang Y, Huang C, Fan L. Effects of a Smartphone-Based Out-of-Hospital Screening App for Neonatal Hyperbilirubinemia on Neonatal Readmission Rates and Maternal Anxiety: Randomized Controlled Trial. J Med Internet Res 2022; 24:e37843. [DOI: 10.2196/37843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2022] [Revised: 08/16/2022] [Accepted: 09/06/2022] [Indexed: 11/24/2022] Open
Abstract
Background
Neonatal hyperbilirubinemia is one of the leading causes of neonatal readmission—especially severe hyperbilirubinemia and its complications—and it influences disease burden as well as neonatal and maternal health. Smartphones have been shown to have satisfactory accuracy in screening neonatal bilirubin levels, but the impact of this technology on neonatal health care service and maternal health outcomes is still unknown.
Objective
The aim of this study was to evaluate the impact of a smartphone-based out-of-hospital neonatal jaundice screening program on neonatal readmission rates for jaundice and related maternal anxiety.
Methods
This was a 2-arm, unblinded, randomized controlled trial with 30 days of intervention and follow-up periods. From August 2019 to August 2020, healthy mother-infant dyads were recruited on-site from 3 public hospitals in Hainan, China. Intervention group mothers used the smartphone app to routinely monitor neonatal jaundice at home under the web-based guidance of pediatricians. Control group participants received routine care. The primary study outcome was the neonatal readmission rate due to jaundice within 30 days of the first hospital discharge. The secondary outcome was the maternal anxiety score associated with neonatal jaundice. The data were collected through a self-assessed questionnaire. All participants were included in the analysis (intention-to-treat).
Results
In this study, 1424 mother-infant dyads were recruited, comprising 1424 mothers and 1424 newborns. The median age
of the mothers was 29 (IQR 26-32) years, and there were 714 (50.1%) male neonates. These mother-infant dyads were randomly
assigned to the intervention group and the control group, with 712 dyads in each group; only 1187 of these dyads completed the
follow-up. We found that the adjusted 30-day neonatal readmission rate due to jaundice reduced by 10.5% (71/605, 11.7% vs
141/582, 24.2%; 95% CI 5%-15.9%; odds ratio 0.4, 95% CI 0.3-0.5; P<.001) and the relevant maternal anxiety mean score
decreased by 3.6 (95% CI –4.4 to –2.8; β=–3.6, 95% CI –4.5 to –2.8; P<.001) in the intervention group compared to those in the
routine care group.
Conclusions
Our study shows that the smartphone-based out-of-hospital screening method for neonatal hyperbilirubinemia decreased the neonatal readmission rate within 30 days from the first discharge and improved maternal mental health to some degree, thus demonstrating the usefulness of this screening app for follow-up in pediatric care.
Trial Registration
China Clinical Trial Registration Center, ChiCTR2100049567; http://www.chictr.org.cn/showproj.aspx?proj=64245
Collapse
|
3
|
Evaluation of the Relationship Between Transcutaneous Bilirubin Measurement and Total Serum Bilirubin in Neonatal Patients Followed for Jaundice. MEDICAL BULLETIN OF SISLI ETFAL HOSPITAL 2021; 55:262-267. [PMID: 34349605 PMCID: PMC8298076 DOI: 10.14744/semb.2020.79837] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Accepted: 04/13/2020] [Indexed: 11/25/2022]
Abstract
Objectives: Jaundice is a physiological condition caused by hyperbilirubinemia, which is common in neonatal period. However, severe hyperbilirubinemia can cause kernicterus, which is a serious condition that leads to neurological problems. In this study, we aimed to investigate whether it is safe to use transcutaneous bilirubin (TcB) instead of blood for the evaluation of jaundice by comparing TcB measurement with standard total serum bilirubin (TSB) measurement values. Methods: A total of 105 term and early term infants with gestational ages between 37 and 42 weeks were included in the study. MBJ20 TcB measuring device was used for TcB measurement. TcB was measured from the forehead and sternum. To evaluate the relationship between TcB measurements and TSB measurements, we performed Pearson correlation, Spearman correlation, linear regression analysis, and Bland-Altman analysis in which we evaluated the scatter plot of the differences between the average values of the measurements. Results: There was a positive and statistically significant correlation between TcB forehead and TSB measurements and TcB sternum and TSB measurements (p<0.001). Linear regression analysis showed a positive directional correlation between TcB forehead and TSB measurements (R²=0.85) and TcB sternum and TSB measurements (R²=0.87). Bland-Altman analysis showed a good consistency between TSB and TcB forehead measurement methods (mean difference: 0.39±1.46, 95% CI: [−2.47]–[3.26]), and between TSB and TcB sternum measurement methods (mean difference: 0.49±1.32 95% CI: [−2.1]–[3.07]). Conclusion: As a result of our study, we found that TcB measurement can be reliable instead of taking blood for jaundice evaluation.
Collapse
|
4
|
Reproducibility of BiliCare™ Transcutaneus Bilirrubin Meter in Mexican Newborns. Int J Pediatr 2019; 2019:3812152. [PMID: 30713561 PMCID: PMC6333005 DOI: 10.1155/2019/3812152] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2018] [Revised: 10/30/2018] [Accepted: 12/02/2018] [Indexed: 11/17/2022] Open
Abstract
Background Newborn hyperbilirubinemia is considered a worldwide health problem that demands medical evaluation. Noninvasive transcutaneous bilirubin (TcB) has been used as a screening method with different devices but there has not been any evaluation of reproducibility of the same brand devices. The BiliCare™ system is evaluated to demonstrate consistency between measurements with four different devices. Methods 336 TcB measurements were obtained with four BiliCare™ devices in 21 Mexican icteric newborns with a mean postnatal age of 44.1 hours of life and 38 weeks of gestation (33–41). Two measurements were taken in the same ear alternatively at the scaphoid fossa with each device. TcB values were compared between devices. Validity was compared with total serum bilirubin (TB). Results intraclass correlation coefficient demonstrates a minimum limit in the study of 0.945 and maximum of 0.988 with the same device. Correlations with serum and between devices gave results above 0.932. Conclusions BiliCare™ transcutaneous bilirubin measurement instrument has very good intra- and interdevice reproducibility; also correlation of TcS with serum bilirubin gave statistically the same results.
Collapse
|
5
|
Sufian AT, Jones GR, Shabeer HM, Elzagzoug EY, Spencer JW. Chromatic techniques for in vivo monitoring jaundice in neonate tissues. Physiol Meas 2018; 39:095004. [PMID: 30129925 DOI: 10.1088/1361-6579/aadbdb] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE A chromatic method is described for providing a preliminary indication of unacceptable bilirubin levels in a newly born baby in order to avoid the development of serious mental deficiencies. The aim was to investigate the reliability of a new chromatic approach using a novel template unit for a preliminary, non-invasive monitoring of the skin tissue of newly born babies with jaundice and its capability for use with different mobile phone cameras. APPROACH A description of the monitoring system is given along with an explanation of the monitoring technique used. Preliminary tests have been performed on 48 different neonates each being addressed by one of six different mobile phone cameras, which were randomly available to the operating clinicians. MAIN RESULTS The test results have a correlation (R 2) of 0.81, a sensitivity (Sn) of 0.97, a specificity (Sp) of 0.82, a positive predictive value (PPV) of 0.95 and a negative predictive value (NPV) of 0.9. SIGNIFICANCE The significance of the results obtained is that they show the approach to have a high level of fail-safe reliability in indicating the bilirubin levels when compared with blood test results. The results also show that the approach can be used with a few different mobile phone cameras and that because of its non-invasive nature and its cost effectiveness, has the potential for remote use from a medical hospital to provide an immediate preliminary diagnosis.
Collapse
Affiliation(s)
- A T Sufian
- Department of Electrical Engineering and Electronics, Centre for Intelligent Monitoring Systems, University of Liverpool, Liverpool L69 3GJ, United Kingdom
| | | | | | | | | |
Collapse
|
6
|
Prediction of significant hyperbilirubinemia in term neonates by early non-invasive bilirubin measurement. World J Pediatr 2017; 13:222-227. [PMID: 27878783 DOI: 10.1007/s12519-016-0067-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2014] [Accepted: 05/13/2015] [Indexed: 10/20/2022]
Abstract
BACKGROUND Neonatal jaundice is a common problem. We evaluated the utility and best cut-off values of 24-and 48-hour transcutaneous bilirubin indices (TcBI) in predicting subsequent significant hyperbilirubinemia and evaluated various associated maternal and fetal risk factors. METHODS TcBI at 24 and 48 hours and serum bilirubin levels at 72 hours of age were obtained for healthy, term, appropriate for gestational age neonates. Neonates with prematurity, birth weight <2500 g, ABO or Rh incompatibility, onset of clinical jaundice <24 hours, clinical suspicion of septicemia, positive pressure ventilation at birth, admission in neonatal intensive care unit and contraindications for BiliChek were excluded. Twently-four and 48-hour TcB indices were assessed as predictors of subsequent hyperbilirubinemia, defined as serum bilirubin >17 mg/dL after 72 hours of life and various cut-offs, and were evaluated by calculating sensitivity, specificity and predictive values. RESULTS Of 500 newborns, 4.6% had significant hyperbilirubinemia, 27% had TcBI (mg/dL) <5 at 24 hours, and 27.4% had TcBI <8 at 48 hours. None of them had subsequent hyperbilirubinemia (100% negative predictive value). The percentage of newborns with subsequent hyperbilirubinemia increased from 3.4% to 13.2% as their 24-hour TcBI increased from 6 to above 9 mg/dL and from 4.2% to 7.4% as their 48-hour TcBI increased from 8 to above 11 mg/dL. The best cut-off value was TcBI (mg/dL) 7 (odd ratio=4.86, 95% confidence interval: 1.66-15.22) at 24 hours and 10 (odd ratio=2.87, 95% confidence interval: 1.04-8.29) at 48 hours. Area under the receiver operating characteristic curve for 24- and 48-hour measurements was 0.750 and 0.715, respectively. Maternal premature rupture of membranes, deep transverse arrest, post-date pregnancy, and fetal distress were significant risk factors for hyperbilirubinemia. CONCLUSIONS Twenty-four and 48-hour TcB indices are good predictors of subsequent hyperbilirubinemia. Twenty-four-hour TcBI had better predictive ability than 48-hour TcBI.
Collapse
|
7
|
Katayama Y, Enomoto M, Kikuchi S, Takei A, Ikegami H, Minami H, Lee YK. Transcutaneous bilirubin measurement during phototherapy in term neonates. Pediatr Int 2017; 59:686-690. [PMID: 28118513 DOI: 10.1111/ped.13248] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/27/2016] [Revised: 01/14/2017] [Accepted: 01/19/2017] [Indexed: 12/20/2022]
Abstract
BACKGROUND We tested whether direct transcutaneous bilirubin (TcB) measurement from an area unexposed to phototherapy is reliable for estimation of total serum bilirubin (TSB) in neonates during phototherapy and whether it contributes to reduction in TSB blood sampling in phototherapy decision making. METHODS This was a retrospective observational study of term neonates who received phototherapy in the mother's room. TSB and TcB from the neonate's sternum were measured before and during phototherapy and compared using linear regression analysis and Bland-Altman plot, respectively. Various cut-offs of TcB for estimating TSB during phototherapy at >72 h after birth were analyzed. RESULTS There were moderate correlations between TSB and TcB before (r = 0.56) and during (r = 0.47) phototherapy in 125 neonates. The mean difference (TSB-TcB) before and during phototherapy was 1.2 ± 1.7 mg/dL and 1.0 ± 1.7 mg/dL, respectively. The 95% limits of agreement for the difference before and during phototherapy ranged from -2.1 to 4.5 and from -2.3 to 4.3 mg/dL, respectively. For TSB ≤18 mg/dL during phototherapy, a TcB cut-off of 14 mg/dL had a specificity of 1.0; with this method, 43% of the TSB measurements could have been avoided. CONCLUSIONS Direct measurement of TcB during phototherapy using a bed-type device is a reliable method to estimate TSB in term neonates and would contribute to a reduction in blood sampling. It cannot, however, be used as a substitute for TSB measurement.
Collapse
Affiliation(s)
| | - Masahiro Enomoto
- Department of Pediatrics, Takatsuki General Hospital, Takatsuki, Japan
| | - Shin Kikuchi
- Department of Pediatrics, Takatsuki General Hospital, Takatsuki, Japan
| | - Atsuko Takei
- Department of Pediatrics, Takatsuki General Hospital, Takatsuki, Japan
| | - Hitoshi Ikegami
- Department of Pediatrics, Takatsuki General Hospital, Takatsuki, Japan
| | - Hirotaka Minami
- Department of Pediatrics, Takatsuki General Hospital, Takatsuki, Japan
| | - Yong Kye Lee
- Department of Pediatrics, Aijinkai Rehabilitation Hospital, Takatsuki, Japan
| |
Collapse
|
8
|
Lain SJ, Roberts CL, Bowen JR, Nassar N. Early discharge of infants and risk of readmission for jaundice. Pediatrics 2015; 135:314-21. [PMID: 25583922 DOI: 10.1542/peds.2014-2388] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVES To examine the association between early discharge from hospital after birth and readmission to hospital for jaundice among term infants, and among infants discharged early, to investigate the perinatal risk factors for readmission for jaundice. METHODS Birth data for 781,074 term live-born infants born in New South Wales, Australia from 2001 to 2010 were linked to hospital admission data. Logistic regression models were used to investigate the association between postnatal length of stay (LOS), gestational age (GA), and readmission for jaundice in the first 14 days of life. Other significant perinatal risk factors associated with readmission for jaundice were examined for infants discharged in the first 2 days after birth. RESULTS Eight per 1000 term infants were readmitted for jaundice. Infants born at 37 weeks' GA with an LOS at birth of 0 to 2 days were over 9 times (adjusted odds ratio [aOR] 9.43; 95% CI, 8.34-10.67) and at 38 weeks' GA were 4 times (aOR 4.05; 95% CI, 3.62-4.54) more likely to be readmitted for jaundice compared with infants born at 39 weeks' GA with an LOS of 3 to 4 days. Other significant risk factors for readmission for jaundice for infants discharged 0 to 2 days after birth included vaginal birth, born to mothers from an Asian country, born to first-time mothers, or being breastfed at discharge. CONCLUSIONS This study can inform guidelines or policy about identifying infants at risk for readmission for jaundice and ensure that appropriate post-discharge follow-up is received.
Collapse
Affiliation(s)
- Samantha J Lain
- Kolling Institute Clinical and Perinatal Population Health Research, University of Sydney, Sydney, Australia; and
| | - Christine L Roberts
- Kolling Institute Clinical and Perinatal Population Health Research, University of Sydney, Sydney, Australia; and
| | - Jennifer R Bowen
- Department of Neonatology, Royal North Shore Hospital, Sydney, Australia
| | - Natasha Nassar
- Kolling Institute Clinical and Perinatal Population Health Research, University of Sydney, Sydney, Australia; and
| |
Collapse
|
9
|
Abstract
Although the modern era of transcutaneous bilirubin monitoring (TcB) began only about 35 years ago, this screening tool is now widely used in newborn nurseries and outpatient clinics, offices, and emergency departments to obtain a rapid and non-invasive estimate of the degree of hyperbilirubinemia. TcB devices have become more sophisticated, and major breakthroughs include the following: (a) ability to report a bilirubin value rather than an index value, (b) enhanced correction for chromophores other than bilirubin, and (c) technologic improvements including interface with electronic medical records. Good agreement with laboratory bilirubin measurement has been demonstrated, and the ability of TcB screening to predict and decrease the incidence of subsequent hyperbilirubinemia has been well-documented. To date, it has not been shown that this screening results in improved long-term outcomes.
Collapse
Affiliation(s)
- William D Engle
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390-9063.
| | - Gregory L Jackson
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390-9063
| | - Nancy G Engle
- College of Nursing, University of Texas Arlington, Arlington, TX
| |
Collapse
|
10
|
Le LT, Partridge JC, Tran BH, Le VT, Duong TK, Nguyen HT, Newman TB. Care practices and traditional beliefs related to neonatal jaundice in northern Vietnam: a population-based, cross-sectional descriptive study. BMC Pediatr 2014; 14:264. [PMID: 25316215 PMCID: PMC4287314 DOI: 10.1186/1471-2431-14-264] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2014] [Accepted: 09/29/2014] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The National Hospital of Pediatrics in Vietnam performed >200 exchange transfusions annually (2006-08), often on infants presenting encephalopathic from lower-level hospitals. As factors delaying care-seeking are not known, we sought to study care practices and traditional beliefs relating to neonatal jaundice in northern Vietnam. METHODS We conducted a prospective, cross-sectional, population-based, descriptive study from November 2008 through February 2010. We prospectively identified mothers of newborns through an on-going regional cohort study. Trained research assistants administered a 78-item questionnaire to mothers during home visits 14-28 days after birth except those we could not contact or whose babies remained hospitalized at 28 days. RESULTS We enrolled 979 mothers; 99% delivered at a health facility. Infants were discharged at a median age of 1.35 days. Only 11% received jaundice education; only 27% thought jaundice could be harmful. During the first week, 77% of newborns were kept in dark rooms. Only 2.5% had routine follow-up before 14 days. Among 118 mothers who were worried by their infant's jaundice but did not seek care, 40% held non-medical beliefs about its cause or used traditional therapies instead of seeking care. Phototherapy was uncommon: 6 (0.6%) were treated before discharge and 3 (0.3%) on readmission. However, there were no exchange transfusions, kernicterus cases, or deaths. CONCLUSIONS Early discharge without follow-up, low maternal knowledge, cultural practices, and use of traditional treatments may limit or delay detection or care-seeking for jaundice. However, in spite of the high prevalence of these practices and the low frequency of treatment, no bad outcomes were seen in this study of nearly 1,000 newborns.
Collapse
Affiliation(s)
- Loc T Le
- Department of Pediatrics, University of California, San Francisco, Box 0748, 533 Parnassus Ave, U585, San Francisco, CA 94143, USA.
| | | | | | | | | | | | | |
Collapse
|
11
|
Effect of universal neonatal transcutaneous bilirubin screening on blood draws for bilirubin analysis and phototherapy usage. J Perinatol 2012; 32:851-5. [PMID: 22343396 DOI: 10.1038/jp.2012.10] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE To determine the effect of universal transcutaneous bilirubin (TcB) screening on total serum bilirubin (TSB) blood draws and phototherapy usage. STUDY DESIGN The subjects were infants ≥ 36 weeks gestation. In period 1, TSB was ordered based on clinical factors. In period 2, all infants underwent predischarge TcB measurement; infants with adjusted TcB values in the high-intermediate or high-risk zones had TSB ordered. Data were extracted through chart review. RESULT TSB measurements per 1000 infants decreased from 717 to 713 (P=0.008) between period 1 and 2, with more outpatient and less inpatient blood draws in period 2. Between periods 1 and 2, total phototherapy decreased from 59 to 39 per 1000 infants (P<0.0001), with less inpatient and more readmission phototherapy. CONCLUSION Universal TcB screening was implemented without increasing total blood draws or phototherapy treatment; however, it was associated with a shift in blood draws and phototherapy usage from inpatients to outpatients.
Collapse
|
12
|
Bosschaart N, Kok JH, Newsum AM, Ouweneel DM, Mentink R, van Leeuwen TG, Aalders MCG. Limitations and opportunities of transcutaneous bilirubin measurements. Pediatrics 2012; 129:689-94. [PMID: 22430456 DOI: 10.1542/peds.2011-2586] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVE Although transcutaneous bilirubinometers have existed for over 30 years, the clinical utility of the technique is limited to a screening method for hyperbilirubinemia, rather than a replacement for invasive blood sampling. In this study, we investigate the reason for this limited clinical value and address possibilities for improvement. METHODS To obtain better insight into the physiology of bilirubin measurements, we evaluated a transcutaneous bilirubinometer that determines not only the cutaneous bilirubin concentration (TcB) but also the blood volume fraction (BVF) in the investigated skin volume. For 49 neonates (gestational age 30 ± 3.1 weeks, postnatal age 6 [4-10] days) at our NICU, we performed 124 TcB and 55 BVF measurements. RESULTS The TcB correlated well with the total serum bilirubin concentration (TSB) (r = 0.88) with an uncertainty of 55 µmol/L. The BVF in the measured skin volume ranged between 0.1% and 0.75%. CONCLUSIONS The performance of our bilirubinometer is comparable to existing transcutaneous devices. The limited clinical value of current bilirubinometers can be explained by the low BVF in the skin volume that is probed by these devices. Because the TcB depends for over 99% on the contribution of extravascular bilirubin, it is a physiologically different parameter from the TSB. Hence, the standard method of evaluation that compares the TcB to the TSB is insufficient to fully investigate the clinical value of transcutaneous bilirubinometers, ie, their predictive value for kernicterus. We suggest that the clinical value may be improved considerably by changing either the method of evaluation or the technological design of transcutaneous bilirubinometers.
Collapse
Affiliation(s)
- Nienke Bosschaart
- Biomedical Engineering and Physics, Academic Medical Center, University of Amsterdam, Amsterdam, Netherlands.
| | | | | | | | | | | | | |
Collapse
|
13
|
Wainer S, Parmar SM, Allegro D, Rabi Y, Lyon ME. Impact of a transcutaneous bilirubinometry program on resource utilization and severe hyperbilirubinemia. Pediatrics 2012; 129:77-86. [PMID: 22184646 DOI: 10.1542/peds.2011-0599] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVES Our goal was to assess the impact of programmatic and coordinated use of transcutaneous bilirubinometry (TcB) on the incidence of severe neonatal hyperbilirubinemia and measures of laboratory, hospital, and nursing resource utilization. METHODS We compared the neonatal hyperbilirubinemia-related outcomes of 14 796 prospectively enrolled healthy infants ≥35 weeks gestation offered routine TcB measurements in both hospital and community settings by using locally validated nomograms relative to a historical cohort of 14 112 infants assessed by visual inspection alone. RESULTS There was a 54.9% reduction (odds ratio [OR]: 2.219 [95% confidence interval (CI): 1.543-3.193]; P < .0001) in the incidence of severe total serum bilirubin values (≥342 µmol/L; ≥20 mg/dL) after implementation of routine TcB measurements. TcB implementation was associated with reductions in the overall incidence of total serum bilirubin draws (134.4 vs 103.6 draws per 1000 live births, OR: 1.332 [95% CI: 1.226-1.446]; P < .0001) and overall phototherapy rate (5.27% vs 4.30%, OR: 1.241 [95% CI: 1.122-1.374]; P < .0001), a reduced age at readmission for phototherapy (104.3 ± 52.1 vs 88.9 ± 70.5 hours, P < .005), and duration of phototherapy readmission (24.8 ± 13.6 vs 23.2 ± 9.8 hours, P < .05). There were earlier (P < .01) and more frequent contacts with public health nurses (1.33 vs 1.66, P < .01) after introduction of the TcB program. CONCLUSIONS Integration of routine hospital and community TcB screening within a comprehensive public health nurse newborn follow-up program is associated with significant improvements in resource utilization and patient safety.
Collapse
Affiliation(s)
- Stephen Wainer
- Department of Pediatrics, Alberta Children's Hospital, 2888 Shaganappi Trail NW, Calgary, AB T3B 6A8, Canada.
| | | | | | | | | |
Collapse
|
14
|
Wainer S, Rabi Y, Parmar SM, Allegro D, Lyon M. Impact of skin tone on the performance of a transcutaneous jaundice meter. Acta Paediatr 2009; 98:1909-15. [PMID: 19764923 DOI: 10.1111/j.1651-2227.2009.01497.x] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
AIM To evaluate the performance of the Konica Minolta/Air-Shields JM-103 jaundice meter on the basis of infant skin tone during the early neonatal period. METHODS Infants were prospectively categorized into light, medium and dark skin tone groups relative to two reference colours. Transcutaneous bilirubin readings were taken at predetermined intervals through the early neonatal period on a convenience sample of 938 healthy infants > or =37 weeks gestation. Serum bilirubin measurements were drawn routinely with metabolic studies and repeated in the presence of an elevated transcutaneous reading or clinically significant jaundice. RESULTS Multivariate linear regression analysis showed a significant impact on serum and transcutaneous bilirubin agreement by skin tone. Highest precision and lowest bias were observed for medium skin toned infants. Greater disagreement between serum and transcutaneous measurements was noted at serum bilirubin concentrations >200 micromol/L. Insufficient numbers of dark skin toned infants were enrolled to evaluate fully the performance of the jaundice meter for this group. CONCLUSION The JM-103 jaundice meter displayed good correlation with serum bilirubin concentrations in light and medium skin tone infants, although it showed a tendency to under-read in the lighter skin tone group and to over-read in the darker skin tone group. The device shows excellent performance characteristics for use as a screening device.
Collapse
Affiliation(s)
- Stephen Wainer
- Division of Community Paediatrics, Faculty of Medicine, University of Calgary, Calgary, AB, Canada.
| | | | | | | | | |
Collapse
|
15
|
Trikalinos TA, Chung M, Lau J, Ip S. Systematic review of screening for bilirubin encephalopathy in neonates. Pediatrics 2009; 124:1162-71. [PMID: 19786450 DOI: 10.1542/peds.2008-3545] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
CONTEXT Severe neonatal hyperbilirubinemia is associated with chronic bilirubin encephalopathy (kernicterus). OBJECTIVE To systematically review the effectiveness of specific screening modalities to prevent neonatal bilirubin encephalopathy. METHODS We identified studies through Medline searches, perusing reference lists and by consulting with US Preventive Services Task Force lead experts. We included English-language publications evaluating the effects of screening for bilirubin encephalopathy using early total serum bilirubin (TSB), transcutaneous bilirubin (TcB) measurements, or risk scores. Severe hyperbilirubinemia was used as a surrogate for possible chronic bilirubin encephalopathy, because no studies directly evaluated the latter as an outcome. We calculated the sensitivity and specificity of early TSB, TcB measurements, or risk scores in detecting hyperbilirubinemia. RESULTS Ten publications (11 studies) were eligible. Seven (2 prospective) studies evaluated the ability of risk factors (n = 3), early TSB (n = 3), TcB (n = 2), or combinations of risk factors and early TSB (n = 1) to predict hyperbilirubinemia (typically TSB > 95th hour-specific percentile 24 hours to 30 days postpartum). Screening had good ability to detect hyperbilirubinemia: reported area-under-the-curve values ranged between 0.69 and 0.84, and reported sensitivities and specificities suggested similar diagnostic ability. Indirect evidence from 3 descriptive uncontrolled studies suggests favorable associations between initiation of screening and decrease in hyperbilirubinemia rates, and rates of treatment or readmissions for hyperbilirubinemia compared with the baseline of no screening. No study assessed harms of screening. CONCLUSIONS Effects of screening on the rates of bilirubin encephalopathy are unknown. Although screening can predict hyperbilirubinemia, there is no robust evidence to suggest that screening is associated with favorable clinical outcomes.
Collapse
Affiliation(s)
- Thomas A Trikalinos
- Tufts Evidence-Based Practice Center and Center for Clinical Evidence Synthesis, Institute for Clinical Research and Health Policy Studies, Boston, Massachusetts 02111, USA
| | | | | | | |
Collapse
|
16
|
Kuzniewicz MW, Escobar GJ, Newman TB. Impact of universal bilirubin screening on severe hyperbilirubinemia and phototherapy use. Pediatrics 2009; 124:1031-9. [PMID: 19786442 PMCID: PMC2858633 DOI: 10.1542/peds.2008-2980] [Citation(s) in RCA: 95] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVE The goal was to assess the impact of universal bilirubin screening on severe hyperbilirubinemia and phototherapy use. METHODS In this retrospective cohort study of 358086 infants of > or =35 weeks and > or =2000 g born between January 1, 1995, and June 30, 2007, we obtained demographic data, bilirubin levels, and codes for inpatient phototherapy from existing databases. We compared the incidence of high total serum bilirubin (TSB) levels and phototherapy before and after implementation of universal screening and examined risk factors for high TSB levels. RESULTS A total of 38182 infants (10.6%) were born at facilities that had implemented universal bilirubin screening. Compared with infants born at facilities that were not screening, these infants had a 62% lower incidence of TSB levels exceeding the American Academy of Pediatrics exchange guideline (0.17% vs 0.45%; P < .001), received twice the inpatient phototherapy (9.1% vs 4.2%; P < .001), and had slightly longer birth hospitalization lengths of stay (50.9 vs 48.7 hours; P < .001). Of those receiving phototherapy, 56% after initiation of universal screening had TSB levels at which phototherapy was recommended by the guideline, compared with 70% before screening. The adjusted odds ratio for developing TSB levels exceeding the guideline value was 0.28 (95% confidence interval: 0.20-0.40) for those born at a facility using TSB screening and 0.28 (95% confidence interval: 0.19-0.42) for those born at a facility using transcutaneous bilirubin screening. CONCLUSIONS Universal bilirubin screening was associated with a significantly lower incidence of severe hyperbilirubinemia but also with increased phototherapy use.
Collapse
Affiliation(s)
- Michael W. Kuzniewicz
- Division of Neonatology, Department of Pediatrics, University of California, San Francisco, California
| | - Gabriel J. Escobar
- Division of Research, Perinatal Research Unit, Kaiser Permanente Medical Care Program, Oakland, California
| | - Thomas B. Newman
- Division of Research, Perinatal Research Unit, Kaiser Permanente Medical Care Program, Oakland, California,Division of Clinical Epidemiology, Department of Epidemiology and Biostatistics, University of California, San Francisco, California,Division of General Pediatrics, Department of Pediatrics, University of California, San Francisco, California
| |
Collapse
|
17
|
El-Beshbishi SN, Shattuck KE, Mohammad AA, Petersen JR. Hyperbilirubinemia and Transcutaneous Bilirubinometry. Clin Chem 2009; 55:1280-7. [DOI: 10.1373/clinchem.2008.121889] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
AbstractBackground: Neonatal jaundice or hyperbilirubinemia is a common occurrence in newborns. Although most cases of neonatal jaundice have a benign course, severe hyperbilirubinemia can lead to kernicterus, which is preventable if the hyperbilirubinemia is identified early and treated appropriately.Content: This review discusses neonatal jaundice and the use of transcutaneous bilirubin (TcB) measurements for identification of neonates at risk of severe hyperbilirubinemia. Such a practice requires appropriate serial testing and result interpretation according to risk level from a nomogram that provides bilirubin concentrations specific for the age of the neonate in hours. In this context, we have evaluated the potential impact on clinical outcome and limitations of TcB methods in current use.Summary: TcB measurement is a viable option in screening neonates to determine if they are at risk for clinically significant hyperbilirubinemia. Total serum bilirubin should be measured by a clinical laboratory if a newborn is shown to be at higher risk for clinically significant hyperbilirubinemia. In addition, external quality assessment to identify biases and operator training issues should be part of any TcB monitoring program.
Collapse
Affiliation(s)
| | | | - Amin A Mohammad
- Department of Pathology, University of Texas Medical Branch, Galveston, TX
| | - John R Petersen
- Department of Pathology, University of Texas Medical Branch, Galveston, TX
| |
Collapse
|
18
|
Carceller-Blanchard A, Cousineau J, Delvin EE. Point of care testing: transcutaneous bilirubinometry in neonates. Clin Biochem 2008; 42:143-9. [PMID: 18929553 DOI: 10.1016/j.clinbiochem.2008.09.106] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2008] [Revised: 09/19/2008] [Accepted: 09/19/2008] [Indexed: 10/21/2022]
Abstract
Physicians taking care of infants in the first days of life are often faced with neonatal jaundice, especially in an era where post-partum discharge occurs earlier and assessment of newborn bilirubinemia status is required prior to discharge. The Canadian Pediatric Society and the American Academy of Pediatrics have developed and published guidelines for the diagnosis and management of hyperbilirubinemia in newborns. Point of care testing refers to any test performed outside of laboratory by clinical personnel and close to the site of patient care. Based on a summary of multiple reports during the last twenty years, we realize that devices which provide a non-invasive transcutaneous bilirubin (TcB) measurement have proven to be very useful as screening tools and provide a valid estimate of the total serum bilirubin level (TSB). Published data suggest that these devices provide measurements within 30-50 micromol/L of the TSB levels and can replace laboratory measurement particularly when TSB levels are less than 260 micromol/L. At the present time, in the literature, evidence is insufficient to abandon neonatal serum bilirubin testing and replace it with TcB. Any measurement, TSB or TcB, has potential for error. However, we have evidence that TcB, can help avoiding potential errors associated with even visual assessment of jaundice and may be useful as screening device to detect significant jaundice and decrease a large number of unnecessary skin punctures. The current manuscript is based on a careful comprehensive literature review concerning neonatal hyperbilirubinemia. We consider that this manuscript will help clinicians and laboratory professionals in the management of neonatal jaundice.
Collapse
Affiliation(s)
- A Carceller-Blanchard
- Department of Pediatrics, CHU Sainte-Justine, Université de Montréal, Montréal, Québec, Canada.
| | | | | |
Collapse
|
19
|
Kirk JM. Neonatal jaundice: a critical review of the role and practice of bilirubin analysis. Ann Clin Biochem 2008; 45:452-62. [DOI: 10.1258/acb.2008.008076] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Neonatal jaundice is common, and usually harmless, because of physiological jaundice or breast-feeding. In some neonates unconjugated bilirubin concentration, coupled with other risk factors, is sufficient to allow free bilirubin to cross the blood-brain barrier and cause kernicterus. Another subgroup of infants is jaundiced because of elevated conjugated bilirubin; a marker for a number of pathological conditions. Bilirubin measurement must identify those infants at risk. Transcutaneous bilirubin measurement is increasingly used in healthy infants, especially before early discharge or at home, to assess the need for laboratory bilirubin measurement. Transcutaneous measurements are not covered by laboratory quality assessment schemes. Guidelines on management of neonatal jaundice utilize age in hours and other risk factors to define bilirubin action thresholds, which may be as low as 100 μmol/L for sick premature infants, whereas early discharged babies may only present after bilirubin concentrations are extremely high. Hence, there is a requirement for accurate total bilirubin measurement from <100 to >500 μmol/L, with sufficient precision to assess the rate of bilirubin change with time. Babies presenting with late jaundice always require conjugated bilirubin measurement. It is of concern that many total and direct bilirubin automated kit methods suffer from haemolysis interference, while use of in-house methods or modification of commercial methods has virtually disappeared. External quality assessment has a vital role in providing data on different methods' performance, including accuracy, precision and susceptibility to interference. Laboratories should consider whether their adult bilirubin methods are suitable for neonates.
Collapse
Affiliation(s)
- Jean M Kirk
- Department of Paediatric Biochemistry/Haematology, Royal Hospital for Sick Children, Sciennes Road, Edinburgh EH9 1LF, UK
| |
Collapse
|
20
|
Kaplan M, Shchors I, Algur N, Bromiker R, Schimmel MS, Hammerman C. Visual screening versus transcutaneous bilirubinometry for predischarge jaundice assessment. Acta Paediatr 2008; 97:759-63. [PMID: 18460107 DOI: 10.1111/j.1651-2227.2008.00807.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
OBJECTIVE Comparison of visual screening with transcutaneous bilirubinometry (TcB) in identifying neonates with plasma total bilirubin (PTB) > or =75th percentile. DESIGN In 100 paired readings PTB was 34 +/- 24 micromol/L higher than the TcB counterpart. A TcB reading of 154 micromol/L was therefore regarded as equivalent to a PTB of 188 micromol/L, corresponding to the 75th percentile at 48 h. Predischarge, all newborns were evaluated for jaundice, first by visual inspection and then transcutaneously. PTB was ordered as indicated by visual assessment or if the TcB reading was > or =154 micromol/L. RESULTS Of 346 newborns tested, 25 (7.2%) had a PTB concentration > or =75th percentile. Forty-nine had PTB determinations based on TcB compared with 83 by visual assessment. However, a similar number of affected newborns was identified by each method (21/25 (84%) by visual screening vs. 18/25 (72%) by TcB). PTB concentrations of those who had been chosen by TcB were higher than those selected visually (202 +/- 24 micromol/L vs. 186 +/- 31 micromol/L). CONCLUSIONS A practical method for predischarge detection of neonates with plasma total bilirubin concentration > or = 75th percentile, implementing transcutaneous bilirubinometry, is described. The transcutaneous technique required fewer blood tests than visual assessment for similar yield.
Collapse
Affiliation(s)
- Michael Kaplan
- Department of Neonatology Shaare Zedek Medical Center, Jerusalem, Israel.
| | | | | | | | | | | |
Collapse
|
21
|
Bhutani VK, Maisels MJ, Stark AR, Buonocore G. Management of jaundice and prevention of severe neonatal hyperbilirubinemia in infants >or=35 weeks gestation. Neonatology 2008; 94:63-7. [PMID: 18204221 DOI: 10.1159/000113463] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Kernicterus is still occurring but should be largely preventable if health care personnel follow the recommendations listed in this guideline. These recommendations emphasize the importance of universal, systematic assessment of the risk of severe hyperbilirubinemia, lactation support, close follow-up, and prompt intervention when necessary. A systems-based approach to prevent severe neonatal hyperbilirubinemia should be implemented at all birthing facilities and coordinated with continuing ambulatory care. Translational research is needed to better understand the mechanisms of bilirubin neurotoxicity and potential therapeutic interventions.
Collapse
Affiliation(s)
- Vinod K Bhutani
- School of Medicine at Stanford University, Stanford, CA, USA
| | | | | | | | | | | | | |
Collapse
|
22
|
Ho HT, Ng TK, Tsui KC, Lo YC. Evaluation of a new transcutaneous bilirubinometer in Chinese newborns. Arch Dis Child Fetal Neonatal Ed 2006; 91:F434-8. [PMID: 16849367 PMCID: PMC2672758 DOI: 10.1136/adc.2005.090217] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
OBJECTIVE To evaluate the use of a new transcutaneous bilirubinometer (JM-103 Minolta Airshields) for detection of hyperbilirubinaemia in term or near-term healthy Chinese newborns. METHODS Transcutaneous bilirubin (TcB) was used to screen for severe hyperbilirubinaemia in newborn infants. Blood was taken for total serum bilirubin (TSB) measurement if the initial TcB level was higher than the 40th centile in Bhutani's nomogram. Paired TcB and TSB results were then reviewed over 6 months. The correlation as well as the mean difference between the two methods were calculated. The clinical application of TcB with Bhutani's nomogram in the prediction of severe hyperbilirubinaemia in low-risk, medium-risk and high-risk thresholds for phototherapy was also analysed. RESULTS 997 paired TcB and TSB measurements were evaluated in term or near-term newborns. TcB was significantly correlated with TSB, with a correlation coefficient of 0.83 (p<0.001). Their mean difference was 21.7 micromol/l (SD 21.2, p<0.001), with the 95% limits of agreement between -19.9 and 63.3 micromol/l. In both low-risk and medium-risk thresholds for phototherapy, using the 75th centile of Bhutani's nomogram as threshold, TcB could identify all cases and had a sensitivity and negative predictive value of 100% each, a specificity of 56% and positive predictive value of 23%. For high-risk cases, using the 75th centile as cut-off, the sensitivity and negative predictive value were reduced to 86.7% and 97.0%, respectively. CONCLUSION An accurate point-of-care bilirubin analyser facilitates bilirubin screening and avoids unnecessary blood tests. Although using the transcutaneous bilirubinometer JM-103 might result in a significant difference between TcB and TSB measured in Chinese newborns, combining the use of TcB and the 75th centile in Bhutani's nomogram as the cut-off level can identify all cases of significant hyperbilirubinaemia.
Collapse
Affiliation(s)
- H T Ho
- Department of Paediatrics and Adolescent Medicine, Pamela Youde Nethersole Eastern Hospital, Hong Kong SAR, China.
| | | | | | | |
Collapse
|
23
|
Borgard JP, Szymanowicz A, Pellae I, Szmidt-Adjidé V, Rota M. Determination of total bilirubin in whole blood from neonates: results from a French multicenter study. Clin Chem Lab Med 2006; 44:1103-10. [PMID: 16958604 DOI: 10.1515/cclm.2006.202] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
AbstractClin Chem Lab Med 2006;44:1103–10.
Collapse
Affiliation(s)
- Jean-Pierre Borgard
- Biochemistry Laboratory, Centre Hospitalier Intercommunal de Créteil, Créteil, France
| | | | | | | | | |
Collapse
|
24
|
Stevenson DK, Wong RJ, Vreman HJ. Reduction in Hospital Readmission Rates for Hyperbilirubinemia Is Associated with Use of Transcutaneous Bilirubin Measurements. Clin Chem 2005; 51:481-2. [PMID: 15738511 DOI: 10.1373/clinchem.2004.046789] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|