1
|
Xu H, Wu X, Liu Q, Yang C, Shen M, Wang Y, Liu S, Zhao S, Xiao T, Sun M, Ding Z, Bao J, Chen M, Gao M. A Universal Strategy for Enhancing the Circulating miRNAs' Detection Performance of Rolling Circle Amplification by Using a Dual-Terminal Stem-Loop Padlock. ACS NANO 2024; 18:436-450. [PMID: 38149638 PMCID: PMC10786163 DOI: 10.1021/acsnano.3c07721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Revised: 12/15/2023] [Accepted: 12/20/2023] [Indexed: 12/28/2023]
Abstract
Rolling circle amplification (RCA) is one of the most promising nucleic acid detection technologies and has been widely used in the molecular diagnosis of disease. Padlock probes are often used to form circular templates, which are the core of RCA. However, RCA often suffers from insufficient specificity and sensitivity. Here we report a reconstruction strategy for conventional padlock probes to promote their overall performance in nucleic acid detection while maintaining probe functions uncompromised. When two rationally designed stem-loops were strategically placed at the two terminals of linear padlock probes, the specificity of target recognition was enhanced and the negative signal was significantly delayed. Our design achieved the best single-base discrimination compared with other structures and over a 1000-fold higher sensitivity than that of the conventional padlock probe, validating the effectiveness of this reconstruction. In addition, the underlying mechanisms of our design were elucidated through molecular dynamics simulations, and the versatility was validated with longer and shorter padlocks targeting the same target, as well as five additional targets (four miRNAs and dengue virus - 2 RNA mimic (DENV-2)). Finally, clinical applicability in multiplex detection was demonstrated by testing real plasma samples. Our exploration of the structures of nucleic acids provided another perspective for developing high-performance detection systems, improving the efficacy of practical detection strategies, and advancing clinical diagnostic research.
Collapse
Affiliation(s)
- Hanqing Xu
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Xianlan Wu
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Qian Liu
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Cheng Yang
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Man Shen
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Yingran Wang
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Shuai Liu
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Shuang Zhao
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Ting Xiao
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Minghui Sun
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Zishan Ding
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Jing Bao
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Ming Chen
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
- College
of Pharmacy and Laboratory Medicine, Third
Military Medical University (Army Medical University), 30 Gaotanyan, Shapingba District, Chongqing 400038, P. R. China
| | - Mingxuan Gao
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| |
Collapse
|
2
|
Soares RRG, Madaboosi N, Nilsson M. Rolling Circle Amplification in Integrated Microsystems: An Uncut Gem toward Massively Multiplexed Pathogen Diagnostics and Genotyping. Acc Chem Res 2021; 54:3979-3990. [PMID: 34637281 PMCID: PMC8567418 DOI: 10.1021/acs.accounts.1c00438] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The development of robust methods allowing the precise detection of specific nucleic acid sequences is of major societal relevance, paving the way for significant advances in biotechnology and biomedical engineering. These range from a better understanding of human disease at a molecular level, allowing the discovery and development of novel biopharmaceuticals and vaccines, to the improvement of biotechnological processes providing improved food quality and safety, efficient green fuels, and smart textiles. Among these applications, the significance of pathogen diagnostics as the main focus of this Account has become particularly clear during the recent SARS-CoV-2 pandemic. In this context, while RT-PCR is the gold standard method for unambiguous detection of genetic material from pathogens, other isothermal amplification alternatives circumventing rapid heating-cooling cycles up to ∼95 °C are appealing to facilitate the translation of the assay into point-of-care (PoC) analytical platforms. Furthermore, the possibility of routinely multiplexing the detection of tens to hundreds of target sequences with single base pair specificity, currently not met by state-of-the-art methods available in clinical laboratories, would be instrumental along the path to tackle emergent viral variants and antimicrobial resistance genes. Here, we advocate that padlock probes (PLPs), first reported by Nilsson et al. in 1994, coupled with rolling circle amplification (RCA), termed here as PLP-RCA, is an underexploited technology in current arena of isothermal nucleic acid amplification tests (NAATs) providing an unprecedented degree of multiplexing, specificity, versatility, and amenability to integration in miniaturized PoC platforms. Furthermore, the intrinsically digital amplification of PLP-RCA retains spatial information and opens new avenues in the exploration of pathogenesis with spatial multiomics analysis of infected cells and tissue.The Account starts by introducing PLP-RCA in a nutshell focusing individually on the three main assay steps, namely, (1) PLP design and ligation mechanism, (2) RCA after probe ligation, and (3) detection of the RCA products. Each subject is touched upon succinctly but with sufficient detail for the reader to appreciate some assay intricacies and degree of versatility depending on the analytical challenge at hand. After familiarizing the reader with the method, we discuss specific examples of research in our group and others using PLP-RCA for viral, bacterial, and fungal diagnostics in a variety of clinical contexts, including the genotyping of antibiotic resistance genes and viral subtyping. Then, we dissect key developments in the miniaturization and integration of PLP-RCA to minimize user input, maximize analysis throughput, and expedite the time to results, ultimately aiming at PoC applications. These developments include molecular enrichment for maximum sensitivity, spatial arrays to maximize analytical throughput, automation of liquid handling to streamline the analytical workflow in miniaturized devices, and seamless integration of signal transduction to translate RCA product titers (and ideally spatial information) into a readable output. Finally, we position PLP-RCA in the current landscape of NAATs and furnish a systematic Strengths, Weaknesses, Opportunities and Threats analysis to shine light upon unpolished edges to uncover the gem with potential for ubiquitous, precise, and unbiased pathogen diagnostics.
Collapse
Affiliation(s)
- Ruben R. G. Soares
- Department of Biochemistry and Biophysics, Science for Life Laboratory, Stockholm University, 17165 Solna, Sweden
- Division of Nanobiotechnology, Department of Protein Science, Science for Life Laboratory, KTH Royal Institute of Technology, 17165 Solna, Sweden
| | - Narayanan Madaboosi
- Department of Biochemistry and Biophysics, Science for Life Laboratory, Stockholm University, 17165 Solna, Sweden
- Department of Biotechnology, Indian Institute of Technology Madras, Chennai, 600036 Tamil Nadu, India
| | - Mats Nilsson
- Department of Biochemistry and Biophysics, Science for Life Laboratory, Stockholm University, 17165 Solna, Sweden
| |
Collapse
|
3
|
Rolling Circle Amplification as an Efficient Analytical Tool for Rapid Detection of Contaminants in Aqueous Environments. BIOSENSORS-BASEL 2021; 11:bios11100352. [PMID: 34677308 PMCID: PMC8533700 DOI: 10.3390/bios11100352] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/12/2021] [Revised: 09/16/2021] [Accepted: 09/21/2021] [Indexed: 12/16/2022]
Abstract
Environmental contaminants are a global concern, and an effective strategy for remediation is to develop a rapid, on-site, and affordable monitoring method. However, this remains challenging, especially with regard to the detection of various contaminants in complex water environments. The application of molecular methods has recently attracted increasing attention; for example, rolling circle amplification (RCA) is an isothermal enzymatic process in which a short nucleic acid primer is amplified to form a long single-stranded nucleic acid using a circular template and special nucleic acid polymerases. Furthermore, this approach can be further engineered into a device for point-of-need monitoring of environmental pollutants. In this paper, we describe the fundamental principles of RCA and the advantages and disadvantages of RCA assays. Then, we discuss the recently developed RCA-based tools for environmental analysis to determine various targets, including heavy metals, organic small molecules, nucleic acids, peptides, proteins, and even microorganisms in aqueous environments. Finally, we summarize the challenges and outline strategies for the advancement of this technique for application in contaminant monitoring.
Collapse
|
4
|
Cassedy A, Parle-McDermott A, O’Kennedy R. Virus Detection: A Review of the Current and Emerging Molecular and Immunological Methods. Front Mol Biosci 2021; 8:637559. [PMID: 33959631 PMCID: PMC8093571 DOI: 10.3389/fmolb.2021.637559] [Citation(s) in RCA: 71] [Impact Index Per Article: 23.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Accepted: 02/01/2021] [Indexed: 12/14/2022] Open
Abstract
Viruses are ubiquitous in the environment. While many impart no deleterious effects on their hosts, several are major pathogens. This risk of pathogenicity, alongside the fact that many viruses can rapidly mutate highlights the need for suitable, rapid diagnostic measures. This review provides a critical analysis of widely used methods and examines their advantages and limitations. Currently, nucleic-acid detection and immunoassay methods are among the most popular means for quickly identifying viral infection directly from source. Nucleic acid-based detection generally offers high sensitivity, but can be time-consuming, costly, and require trained staff. The use of isothermal-based amplification systems for detection could aid in the reduction of results turnaround and equipment-associated costs, making them appealing for point-of-use applications, or when high volume/fast turnaround testing is required. Alternatively, immunoassays offer robustness and reduced costs. Furthermore, some immunoassay formats, such as those using lateral-flow technology, can generate results very rapidly. However, immunoassays typically cannot achieve comparable sensitivity to nucleic acid-based detection methods. Alongside these methods, the application of next-generation sequencing can provide highly specific results. In addition, the ability to sequence large numbers of viral genomes would provide researchers with enhanced information and assist in tracing infections.
Collapse
Affiliation(s)
- A. Cassedy
- School of Biotechnology, Dublin City University, Dublin, Ireland
| | | | - R. O’Kennedy
- School of Biotechnology, Dublin City University, Dublin, Ireland
- Hamad Bin Khalifa University, Doha, Qatar
- Qatar Foundation, Doha, Qatar
| |
Collapse
|
5
|
Soares RRG, Varela JC, Neogi U, Ciftci S, Ashokkumar M, Pinto IF, Nilsson M, Madaboosi N, Russom A. Sub-attomole detection of HIV-1 using padlock probes and rolling circle amplification combined with microfluidic affinity chromatography. Biosens Bioelectron 2020; 166:112442. [PMID: 32755809 DOI: 10.1016/j.bios.2020.112442] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Revised: 07/01/2020] [Accepted: 07/09/2020] [Indexed: 10/23/2022]
Abstract
Despite significant progress in diagnostics and disease management during the past decades, human immunodeficiency virus (HIV) infections are still responsible for nearly 1 million deaths every year, mostly in resource-limited settings. Thus, novel, accurate and cost-effective tools for viral load monitoring become crucial to allow specific diagnostics and the effective monitoring of the associated antiviral therapies. Herein, we report an effective combination of a (1) padlock probe (PLP)-mediated rolling circle amplification (RCA) bioassay and an (2) agarose bead-based microfluidic device for the affinity chromatography-based capture and detection of RCA products (RCPs) pre-labelled simultaneously with biotin and an organic fluorophore. This method allowed the efficient capture of ~1 μm-sized RCPs followed by their quantification either as discrete signals or an average fluorescence signal, thus being compatible with both high-resolution imaging for maximum sensitivity as well as simpler optical detection setups. A limit of detection < 30 fM was obtained for HIV-1 synthetic target with just a single round of RCA, comparable to recently reported procedures requiring technically complex amplification strategies such as hyperbranching and/or enzymatic digestion/amplification. Furthermore, targeting a set of five conserved regions in the HIV-1 gag gene, the method could specifically detect HIV-1 in 293T cell culture supernatants, as well as a set of 11 HIV-1 NIH reference samples with four different subtypes. The reported method provides simplicity of operation, unique versatility of signal transduction (i.e. average or discrete signals), and potential coupling with previously reported miniaturized photodetectors. These combined features hold promise for bringing RCA-based molecular diagnostics closer to the point-of-care.
Collapse
Affiliation(s)
- Ruben R G Soares
- Division of Nanobiotechnology, Department of Protein Science, Science for Life Laboratory, KTH Royal Institute of Technology, Solna, Sweden; Department of Biochemistry and Biophysics, Science for Life Laboratory, Stockholm University, Solna, Sweden.
| | - João C Varela
- Department of Biochemistry and Biophysics, Science for Life Laboratory, Stockholm University, Solna, Sweden
| | - Ujjwal Neogi
- Division of Clinical Microbiology, Department of Laboratory Medicine, Karolinska Institute, Huddinge, Sweden
| | - Sibel Ciftci
- Department of Biochemistry and Biophysics, Science for Life Laboratory, Stockholm University, Solna, Sweden
| | - Manickam Ashokkumar
- Division of Clinical Microbiology, Department of Laboratory Medicine, Karolinska Institute, Huddinge, Sweden
| | - Inês F Pinto
- Division of Nanobiotechnology, Department of Protein Science, Science for Life Laboratory, KTH Royal Institute of Technology, Solna, Sweden
| | - Mats Nilsson
- Department of Biochemistry and Biophysics, Science for Life Laboratory, Stockholm University, Solna, Sweden.
| | - Narayanan Madaboosi
- Department of Biochemistry and Biophysics, Science for Life Laboratory, Stockholm University, Solna, Sweden.
| | - Aman Russom
- Division of Nanobiotechnology, Department of Protein Science, Science for Life Laboratory, KTH Royal Institute of Technology, Solna, Sweden.
| |
Collapse
|
6
|
Ciftci S, Neumann F, Abdurahman S, Appelberg KS, Mirazimi A, Nilsson M, Madaboosi N. Digital Rolling Circle Amplification-Based Detection of Ebola and Other Tropical Viruses. J Mol Diagn 2020; 22:272-283. [PMID: 31837428 DOI: 10.1016/j.jmoldx.2019.10.014] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Revised: 09/04/2019] [Accepted: 10/23/2019] [Indexed: 02/06/2023] Open
Abstract
Emerging tropical viruses have caused serious outbreaks during the recent years, such as Ebola virus (EBOV) in 2014 and the most recent in 2018 to 2019 in Congo. Thus, immediate diagnostic attention is demanded at the point of care in resource-limited settings, because the performance and the operational parameters of conventional EBOV testing are limited. Especially, their sensitivity, specificity, and coverage of other tropical disease viruses make them unsuitable for diagnostic at the point of care. Here, a padlock probe (PLP)-based rolling circle amplification (RCA) method for the detection of EBOV is presented. For this, a set of PLPs, separately targeting the viral RNA and complementary RNA of all seven EBOV genes, was used in the RCA assay and validated on virus isolates from cell culture. The assay was then translated for testing clinical samples, and simultaneous detection of both EBOV RNA types was demonstrated. For increased sensitivity, the RCA products were enriched on a simple and pump-free microfluidic chip. Because PLPs and RCA are inherently multiplexable, we demonstrate the extension of the probe panel for the simultaneous detection of the tropical viruses Ebola, Zika, and Dengue. The demonstrated high specificity, sensitivity, and multiplexing capability in combination with the digital quantification rendered the assay a promising diagnostic tool toward tropical virus detection at the point of care.
Collapse
Affiliation(s)
- Sibel Ciftci
- Science for Life Laboratory, Department of Biochemistry and Biophysics, Stockholm University, Solna, Sweden
| | - Felix Neumann
- Science for Life Laboratory, Department of Biochemistry and Biophysics, Stockholm University, Solna, Sweden
| | | | | | - Ali Mirazimi
- Public Health Agency of Sweden, Solna, Sweden; LABMED, Karolinska Institute and Karolinska Hospital University, Solna, Sweden; National Veterinary Institute, Uppsala, Sweden
| | - Mats Nilsson
- Science for Life Laboratory, Department of Biochemistry and Biophysics, Stockholm University, Solna, Sweden.
| | - Narayanan Madaboosi
- Science for Life Laboratory, Department of Biochemistry and Biophysics, Stockholm University, Solna, Sweden.
| |
Collapse
|
7
|
Ciftci S, Cánovas R, Neumann F, Paulraj T, Nilsson M, Crespo GA, Madaboosi N. The sweet detection of rolling circle amplification: Glucose-based electrochemical genosensor for the detection of viral nucleic acid. Biosens Bioelectron 2019; 151:112002. [PMID: 31999596 DOI: 10.1016/j.bios.2019.112002] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2019] [Revised: 12/09/2019] [Accepted: 12/27/2019] [Indexed: 01/16/2023]
Abstract
Herein, an isothermal padlock probe-based assay for the simple and portable detection of pathogens coupled with a glucose oxidase (GOx)-based electrochemical readout is reported. Infectious diseases remain a constant threat on a global scale, as in recurring pandemics. Rapid and portable diagnostics hold the promise to tackle the spreading of diseases and decentralising healthcare to point-of-care needs. Ebola, a hypervariable RNA virus causing fatalities of up to 90% for recent outbreaks in Africa, demands immediate attention for bedside diagnostics. The design of the demonstrated assay consists of a rolling circle amplification (RCA) technique, responsible for the generation of nucleic acid amplicons as RCA products (RCPs). The RCPs are generated on magnetic beads (MB) and subsequently, connected via streptavidin-biotin bonds to GOx. The enzymatic catalysis of glucose by the bound GOx allows for an indirect electrochemical measurement of the DNA target. The RCPs generated on the surface of the MB were confirmed by scanning electron microscopy, and among other experimental conditions such as the type of buffer, temperature, concentration of GOx, sampling and measurement time were evaluated for the optimum electrochemical detection. Accordingly, 125 μg mL-1 of GOx with 5 mM glucose using phosphate buffer saline (PBS), monitored for 1 min were selected as the ideal conditions. Finally, we assessed the analytical performance of the biosensing strategy by using clinical samples of Ebola virus from patients. Overall, this work provides a proof-of-concept bioassay for simple and portable molecular diagnostics of emerging pathogens using electrochemical detection, especially in resource-limited settings.
Collapse
Affiliation(s)
- Sibel Ciftci
- Science for Life Laboratory, Department of Biochemistry and Biophysics, Stockholm University, Sweden
| | - Rocío Cánovas
- Department of Chemistry, Royal Institute of Technology, KTH, Teknikringen 30, SE-100 44, Stockholm, Sweden
| | - Felix Neumann
- Science for Life Laboratory, Department of Biochemistry and Biophysics, Stockholm University, Sweden
| | - Thomas Paulraj
- Department of Chemistry, Royal Institute of Technology, KTH, Teknikringen 30, SE-100 44, Stockholm, Sweden
| | - Mats Nilsson
- Science for Life Laboratory, Department of Biochemistry and Biophysics, Stockholm University, Sweden.
| | - Gaston A Crespo
- Department of Chemistry, Royal Institute of Technology, KTH, Teknikringen 30, SE-100 44, Stockholm, Sweden.
| | - Narayanan Madaboosi
- Science for Life Laboratory, Department of Biochemistry and Biophysics, Stockholm University, Sweden.
| |
Collapse
|
8
|
Optomagnetic Detection of Rolling Circle Amplification Products. METHODS IN MOLECULAR BIOLOGY (CLIFTON, N.J.) 2019; 2063:3-15. [PMID: 31667758 DOI: 10.1007/978-1-0716-0138-9_1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Rolling circle amplification (RCA) of a synthetic nucleic acid target is detected using magnetic nanoparticles (MNPs) combined with an optomagnetic (OM) readout. Two RCA assays are developed with on-chip detection of rolling circle products (RCPs) either at end-point where MNPs are mixed with the sample after completion of RCA or in real time where MNPs are mixed with the sample during RCA. The plastic chip acts as a cuvette, which is positioned in a setup integrated with temperature control and simultaneous detection of four parallel DNA hybridization reactions between functionalized MNPs and products of DNA amplification. The OM technique probes the small-angle rotation of MNPs bearing oligonucleotide probes complementary to the repeated nucleotide sequence of the RCPs. This rotation is restricted when MNPs bind to RCPs, which can be observed as a turn-off of the signal from MNPs that are free to rotate. The amount of MNPs bound to RCPs is found to increase in response to the amplification time as well as in response to the synthetic DNA target concentration (2-40 pM dynamic range). We report OM real-time results obtained with MNPs present during RCA and compare to relevant end-point OM results for RCPs generated for different RCA times. The real-time approach avoids opening of tubes post-RCA and thus reduces risk of lab contamination with amplification products without compromising the sensitivity and dynamic range of the assay.
Collapse
|
9
|
Garbarino F, Minero GAS, Rizzi G, Fock J, Hansen MF. Integration of rolling circle amplification and optomagnetic detection on a polymer chip. Biosens Bioelectron 2019; 142:111485. [DOI: 10.1016/j.bios.2019.111485] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Revised: 06/26/2019] [Accepted: 06/28/2019] [Indexed: 01/14/2023]
|
10
|
Minero GAS, Cangiano V, Garbarino F, Fock J, Hansen MF. Integration of microbead DNA handling with optomagnetic detection in rolling circle amplification assays. Mikrochim Acta 2019; 186:528. [DOI: 10.1007/s00604-019-3636-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2019] [Accepted: 06/25/2019] [Indexed: 01/14/2023]
|
11
|
Lakdawala SS, Lee N, Brooke CB. Teaching an Old Virus New Tricks: A Review on New Approaches to Study Age-Old Questions in Influenza Biology. J Mol Biol 2019; 431:4247-4258. [PMID: 31051174 DOI: 10.1016/j.jmb.2019.04.038] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Revised: 04/12/2019] [Accepted: 04/23/2019] [Indexed: 01/31/2023]
Abstract
Influenza viruses have been studied for over 80 years, yet much about the basic viral lifecycle remain unknown. However, new imaging, biochemical, and sequencing techniques have revealed significant insight into many age-old questions of influenza virus biology. In this review, we will cover the role of imaging techniques to describe unique aspects of influenza virus assembly, biochemical techniques to study viral genomic organization, and next-generation sequencing to explore influenza genomic evolution. Our goal is to provide a brief overview of how emerging techniques are being used to answer basic questions about influenza viruses. This is not a comprehensive list of emerging techniques, rather ones that we feel will continue to make significant contributions to field of influenza biology.
Collapse
Affiliation(s)
- Seema S Lakdawala
- Department of Microbiology and Molecular Genetics, University of Pittsburgh, School of Medicine Pittsburgh, PA 15219, USA.
| | - Nara Lee
- Department of Microbiology and Molecular Genetics, University of Pittsburgh, School of Medicine Pittsburgh, PA 15219, USA.
| | - Christopher B Brooke
- Department of Microbiology, University of Illinois at Urbana-Champaign, Champaign, IL 61801, USA; Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Champaign, IL 61801, USA.
| |
Collapse
|
12
|
A novel mutation tolerant padlock probe design for multiplexed detection of hypervariable RNA viruses. Sci Rep 2019; 9:2872. [PMID: 30814634 PMCID: PMC6393471 DOI: 10.1038/s41598-019-39854-3] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2018] [Accepted: 01/31/2019] [Indexed: 12/13/2022] Open
Abstract
The establishment of a robust detection platform for RNA viruses still remains a challenge in molecular diagnostics due to their high mutation rates. Newcastle disease virus (NDV) is one such RNA avian virus with a hypervariable genome and multiple genotypes. Classical approaches like virus isolation, serology, immunoassays and RT-PCR are cumbersome, and limited in terms of specificity and sensitivity. Padlock probes (PLPs) are known for allowing the detection of multiple nucleic acid targets with high specificity, and in combination with Rolling circle amplification (RCA) have permitted the development of versatile pathogen detection assays. In this work, we aimed to detect hypervariable viruses by developing a novel PLP design strategy capable of tolerating mutations while preserving high specificity by targeting several moderately conserved regions and using degenerate bases. For this, we designed nine padlock probes based on the alignment of 335 sequences covering both Class I and II NDV. Our PLP design showed high coverage and specificity for the detection of eight out of ten reported genotypes of Class II NDV field isolated strains, yielding a detection limit of less than ten copies of viral RNA. Further taking advantage of the multiplex capability of PLPs, we successfully extended the assay for the simultaneous detection of three poultry RNA viruses (NDV, IBV and AIV) and combined it with a paper based microfluidic enrichment read-out for digital quantification. In summary, our novel PLP design addresses the current issue of tolerating mutations of highly emerging virus strains with high sensitivity and specificity.
Collapse
|