Dziadzko MA, Harrison AM, Tiong IC, Pickering BW, Moreno Franco P, Herasevich V. Testing modes of computerized sepsis alert notification delivery systems.
BMC Med Inform Decis Mak 2016;
16:156. [PMID:
27938401 PMCID:
PMC5148853 DOI:
10.1186/s12911-016-0396-y]
[Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2016] [Accepted: 11/30/2016] [Indexed: 01/20/2023] Open
Abstract
BACKGROUND
The number of electronic health record (EHR)-based notifications continues to rise. One common method to deliver urgent and emergent notifications (alerts) is paging. Despite of wide presence of smartphones, the use of these devices for secure alerting remains a relatively new phenomenon.
METHODS
We compared three methods of alert delivery (pagers, EHR-based notifications, and smartphones) to determine the best method of urgent alerting in the intensive care unit (ICU) setting. ICU clinicians received randomized automated sepsis alerts: pager, EHR-based notification, or a personal smartphone/tablet device. Time to notification acknowledgement, fatigue measurement, and user preferences (structured survey) were studied.
RESULTS
Twenty three clinicians participated over the course of 3 months. A total of 48 randomized sepsis alerts were generated for 46 unique patients. Although all alerts were acknowledged, the primary outcome was confounded by technical failure of alert delivery in the smartphone/tablet arm. Median time to acknowledgment of urgent alerts was shorter by pager (102 mins) than EHR (169 mins). Secondary outcomes of fatigue measurement and user preference did not demonstrate significant differences between these notification delivery study arms.
CONCLUSIONS
Technical failure of secure smartphone/tablet alert delivery presents a barrier to testing the optimal method of urgent alert delivery in the ICU setting. Results from fatigue evaluation and user preferences for alert delivery methods were similar in all arms. Further investigation is thus necessary to understand human and technical barriers to implementation of commonplace modern technology in the hospital setting.