1
|
Fei X, Zhu L, Han P, Jiang B, Li M, Li N, Jiao Z, Clevert DA, Luo Y. Value of high frame rate contrast-enhanced ultrasound in predicting microvascular invasion of hepatocellular carcinoma. Insights Imaging 2024; 15:273. [PMID: 39546065 PMCID: PMC11568103 DOI: 10.1186/s13244-024-01821-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2024] [Accepted: 09/10/2024] [Indexed: 11/17/2024] Open
Abstract
OBJECTIVES To investigate the value of vascular morphology on high frame rate contrast-enhanced ultrasound (H-CEUS) and CEUS Li-RADS in predicting microvascular invasion (MVI), Ki-67 expression and recurrence of hepatocellular carcinoma (HCC). METHODS This retrospective study enrolled 78 patients with single HCC diagnosed by postoperative pathology between January 1, 2021, and June 30, 2022. All patients underwent ultrasound and H-CEUS examination before operation. H-CEUS image features and CEUS Li-RADS were compared in different MVI status and Ki-67 level. Multiple logistic regression analysis was performed to select independent variables for MVI. Differences in recurrence among different H-CEUS image features, MVI status and Ki-67 level were further analyzed. RESULTS Tumor shape, vascular morphology, LR-M category, necrosis and AFP level were different between the MVI-positive group and MVI-negative group (p < 0.05). Vascular morphology and LR-M category were independent risk factors related to MVI (p < 0.05). Vascular morphology was also different between the high Ki-67 expression group and low Ki-67 expression group (p < 0.05). Vascular morphology, MVI status and Ki-67 expression were different between the recurrence group and no recurrence group (p < 0.05). CONCLUSION The vascular morphology of HCC on H-CEUS can indicate the risk of MVI status, Ki-67 expression and recurrence, which provides a feasible imaging technique for predicting the prognosis before operation. CRITICAL RELEVANCE STATEMENT H-CEUS shows the different vascular morphology of HCC in arterial phase and indicates the risk of MVI, Ki-67 expression and recurrence, which provides a feasible imaging technique for clinician to judge the risk of MVI pre-operation and adopt appropriate treatment. KEY POINTS H-CEUS can clearly show different vascular morphology of HCC in arterial phase. Vascular morphology on H-CEUS is associated with MVI status, Ki-67 expression and HCC recurrence. Preoperative MVI and Ki-67 expression prediction could help surgeons choose a more appropriate treatment plan.
Collapse
Affiliation(s)
- Xiang Fei
- Department of Ultrasound, The First Medical Centre, Chinese PLA General Hospital, Beijing, China
| | - Lianhua Zhu
- Department of Ultrasound, The First Medical Centre, Chinese PLA General Hospital, Beijing, China
| | - Peng Han
- Department of Ultrasound, The First Medical Centre, Chinese PLA General Hospital, Beijing, China
| | - Bo Jiang
- Department of Ultrasound, The First Medical Centre, Chinese PLA General Hospital, Beijing, China
| | - Miao Li
- Department of Ultrasound, The First Medical Centre, Chinese PLA General Hospital, Beijing, China
| | - Nan Li
- Department of Ultrasound, The First Medical Centre, Chinese PLA General Hospital, Beijing, China
| | - Ziyu Jiao
- Department of Ultrasound, The First Medical Centre, Chinese PLA General Hospital, Beijing, China
| | - Dirk-André Clevert
- Interdisciplinary Ultrasound-Center University of Munich-Grosshadern Campus, Munich, Germany.
| | - Yukun Luo
- Department of Ultrasound, The First Medical Centre, Chinese PLA General Hospital, Beijing, China.
| |
Collapse
|
2
|
Wu H, Shi J, Gao L, Wang J, Yuan W, Zhang W, Liu Z, Mao Y. Qualitative and quantitative analysis of solid renal tumors by high-frame-rate contrast-enhanced ultrasound. Cancer Imaging 2024; 24:139. [PMID: 39407335 PMCID: PMC11481758 DOI: 10.1186/s40644-024-00788-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2024] [Accepted: 10/08/2024] [Indexed: 10/19/2024] Open
Abstract
OBJECTIVE To analyze the characteristics of high-frame-rate contrast-enhanced ultrasound (H-CEUS) in solid renal tumors using qualitative and quantitative methods. METHODS Seventy-five patients who underwent preoperative conventional ultrasound (US), conventional contrast-enhanced ultrasound (C-CEUS), and H-CEUS examination of renal tumors were retrospectively analyzed, with a total of 89 renal masses. The masses were divided into the benign (30 masses) and malignant groups (59 masses) based on the results of enhanced computer tomography and pathology. The location, diameter, shape, border, calcification, and color doppler blood flow imaging (CDFI) of the lesions were observed by US, and the characteristics of the C-CEUS and H-CEUS images were qualitatively and quantitatively analyzed. The χ² test or Fisher's exact probability method was used to compare the US image characteristics between the benign and malignant groups, and the image characteristics of C-CEUS and H-CEUS between the benign and malignant groups. Moreover, the nonparametric Mann-Whitney test was used to compare the differences in C-CEUS and H-CEUS time-intensity curve (TIC) parameters. RESULTS Significant differences in gender, surgical approach, echogenicity, and CDFI were observed between the malignant and benign groups (p = 0.003, < 0.001, < 0.001, = 0003). Qualitative analysis also revealed significant differences in the mode of wash-out and fill-in direction between C-CEUS and H-CEUS in the malignant group (p = 0.041, 0.002). In addition, the homogeneity of enhancement showed significant differences between the two contrast models in the benign group (p = 0.009). Quantitative analysis indicated that the TIC parameters peak intensity (PI), deceleration time (DT) /2, area under the curve (AUC), and mean transition time (MTT) were significantly lower in the H-CEUS model compared to the C-CEUS model in both the benign and malignant groups. (all p < 0.001). In contrast, ascending slope of rise curve (AS) was significantly higher in the H-CEUS model compared to the C-CEUS model in the malignant group (p = 0.048). CONCLUSIONS In renal tumors, H-CEUS shows clearer internal enhancement of the mass and the changes in the wash-out period. The quantitative TIC parameters PI, DT/2, AUC, and MTT were lower in H-CEUS compared to C-CEUS. Both the quantitative and qualitative analyses indicated that H-CEUS better displays the characteristics of solid renal masses compared with C-CEUS.
Collapse
Affiliation(s)
- Hailan Wu
- Department of Ultrasound, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China
| | - Jiayu Shi
- The First Clinical Medical College, Jiangxi Medical College, Nanchang University, Nanchang, China
| | - Long Gao
- School of Advanced Manufacturing, Nanchang University, Nanchang, China
| | - Jingling Wang
- Department of Ultrasound, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China
| | - WenXin Yuan
- Department of Ultrasound, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China
| | - WeiPing Zhang
- Department of Ultrasound, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China.
| | - Zhixing Liu
- Department of Ultrasound, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China
| | - Yi Mao
- Department of Ultrasound, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China
| |
Collapse
|
3
|
He JJ, Xiong WL, Sun WQ, Pan QY, Xie LT, Jiang TA. Advances and current research status of early diagnosis for gallbladder cancer. Hepatobiliary Pancreat Dis Int 2024:S1499-3872(24)00123-1. [PMID: 39393997 DOI: 10.1016/j.hbpd.2024.09.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2024] [Accepted: 09/26/2024] [Indexed: 10/13/2024]
Abstract
Gallbladder cancer (GBC) is the most common malignant tumor in the biliary system, characterized by high malignancy, aggressiveness, and poor prognosis. Early diagnosis holds paramount importance in ameliorating therapeutic outcomes. Presently, the clinical diagnosis of GBC primarily relies on clinical-radiological-pathological approach. However, there remains a potential for missed diagnosis and misdiagnose in the realm of clinical practice. We firstly analyzed the blood-based biomarkers, such as carcinoembryonic antigen and carbohydrate antigen 19-9. Subsequently, we evaluated the diagnostic performance of various imaging modalities, including ultrasound (US), endoscopic ultrasound (EUS), computed tomography (CT), magnetic resonance imaging (MRI), positron emission tomography/computed tomography (PET/CT) and pathological examination, emphasizing their strengths and limitations in detecting early-stage GBC. Furthermore, we explored the potential of emerging technologies, particularly artificial intelligence (AI) and liquid biopsy, to revolutionize GBC diagnosis. AI algorithms have demonstrated improved image analysis capabilities, while liquid biopsy offers the promise of non-invasive and real-time monitoring. However, the translation of these advancements into clinical practice necessitates further validation and standardization. The review highlighted the advantages and limitations of current diagnostic approaches and underscored the need for innovative strategies to enhance diagnostic accuracy of GBC. In addition, we emphasized the importance of multidisciplinary collaboration to improve early diagnosis of GBC and ultimately patient outcomes. This review endeavoured to impart fresh perspectives and insights into the early diagnosis of GBC.
Collapse
Affiliation(s)
- Jia-Jia He
- Department of Ultrasound Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310003, China; Department of Ultrasound Medicine, Beilun District People's Hospital, Ningbo 315800, China
| | - Wei-Lv Xiong
- Department of Ultrasound Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310003, China; Department of Ultrasound Medicine, Huzhou Central Hospital, Huzhou 313000, China
| | - Wei-Qi Sun
- Department of Ultrasound Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310003, China; Department of Ultrasound Medicine, The Second Affiliated Hospital, Jiaxing University, Jiaxing 314000, China
| | - Qun-Yan Pan
- Department of Ultrasound Medicine, Beilun District People's Hospital, Ningbo 315800, China
| | - Li-Ting Xie
- Department of Ultrasound Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310003, China
| | - Tian-An Jiang
- Department of Ultrasound Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310003, China.
| |
Collapse
|
4
|
Wang J, Shi J, Gao L, Hu W, Chen M, Zhang W. High-frame-rate contrast-enhanced ultrasound to differentiate between clear cell renal cell carcinoma and angiomyolipoma. BMC Cancer 2024; 24:659. [PMID: 38816725 PMCID: PMC11138005 DOI: 10.1186/s12885-024-12413-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2024] [Accepted: 05/22/2024] [Indexed: 06/01/2024] Open
Abstract
BACKGROUND To investigate the diagnostic efficacy of high-frame-rate contrast-enhanced ultrasound (H-CEUS) in differentiating between clear cell renal cell carcinoma (CCRCC) and angiomyolipoma (AML). METHODS A retrospective study was performed on the clinical data of 79 patients diagnosed with CCRCC and 31 patients diagnosed with AML at the First Affiliated Hospital of Nanchang University between October 2022 and December 2023. Conventional ultrasound (US) and H-CEUS examinations were conducted on all patients prior to surgery, dynamic images were recorded from the US, and the qualitative and quantitative parameters of H-CEUS were collected. The t-test, χ² test and non-parametric Mann-Whitney test were employed to assess differences in clinical data, US characteristics, and qualitative and quantitative parameters of H-CEUS between the CCRCC and AML groups. The independent risk factors of CCRCC were identified using binary logistic regression. The receiver operator characteristic (ROC) curve was constructed to evaluate the diagnostic effectiveness of clinical + US and H-CEUS in differentiating between CCRCC and AML. RESULTS The CCRCC group and the AML group exhibited significant differences in patient gender, operation mode, nodular echo, and nodule blood flow (χ²=11.698, -, -,=10.582; P<0.001, <0.001, <0.001, and = 0.014, respectively). In addition, the H-CEUS qualitative analysis demonstrated significant differences between the AML group and the CCRCC group with respect to enhancement mode, regression mode, peak intensity, enhancement uniformity, no enhancement, and presence or absence of pseudocapsule (χ²=41.614, -, -, = 2.758, = 42.099, -; P<0.001, <0.001, <0.001, 0.097, <0.001, and <0.001, respectively). The Arrival time (AT) in the CCRCC group was significantly shorter than that in the AML group, as determined by quantitative analysis of H-CEUS (Z=-3.266, P = 0.001). Furthermore, the Peak intensity (PI), Ascent slope (AS), and The area under the curve (AUC) exhibited significantly higher values in the CCRCC group compared to the AML group (Z=-2.043,=-2.545,=-3.565; P = 0.041, = 0.011, and <0.001, respectively). Logistic regression analysis indicated that only gender, nodule echo, the pseudocapsule, AS, and AUC of H-CEUS were independent risk factors of CCRCC. The ROC curve revealed that combining gender and nodule echo yielded a sensitivity of 92.4%, specificity of 64.5%, and an AUC of 0.847 in distinguishing between CCRCC and AML. When combining the H-CEUS parameters of pseudocapsule, AS, and AUC, the sensitivity, specificity, and AUC for distinguishing between CCRCC and AML were 84.8%, 96.8%, and 0.918, respectively. No statistically significant difference was observed in the diagnostic effectiveness of the two methods (Z=-1.286, P = 0.198). However, H-CEUS demonstrated better AUC and specificity. CONCLUSIONS H-CEUS enhances the sensitivity and specificity of differentiating between CCRCC and AML by improving the temporal resolution, offering a more precise diagnostic foundation for identifying the most appropriate therapy for patients.
Collapse
Affiliation(s)
- JingLing Wang
- Department of Ultrasound, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China
| | - JiaYu Shi
- The First Clinical Medical College, Jiangxi Medical College, Nanchang University, Nanchang, China
| | - Long Gao
- School of Advanced Manufacturing, Nanchang University, Nanchang, China
| | - WeiHong Hu
- Department of Ultrasound, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China
| | - Miao Chen
- Department of Ultrasound, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China
| | - WeiPing Zhang
- Department of Ultrasound, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China.
| |
Collapse
|
5
|
Cao J, Wang H, Ling W. Compared with SonoVue ® LR-5, Sonazoid ® modified LR-5 has better diagnostic sensitivity for hepatocellular carcinoma: a systematic review and meta-analysis. Quant Imaging Med Surg 2024; 14:2978-2992. [PMID: 38617150 PMCID: PMC11007517 DOI: 10.21037/qims-23-1616] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Accepted: 01/12/2024] [Indexed: 04/16/2024]
Abstract
Background The contrast-enhanced ultrasound (CEUS) liver imaging reporting and data system (LI-RADS) is a standardized system for reporting liver nodules in patients at risk of developing hepatocellular carcinoma (HCC) and is only recommended for pure blood pool agents such as SonoVue®. A modified LI-RADS was proposed for Sonazoid®, a Kupffer cell-specific contrast agent. This meta-analysis was conducted to compare the diagnostic efficiency of the CEUS LI-RADS for SonoVue® and the modified LI-RADS for Sonazoid®. Methods The PubMed, Medline, Web of Science, Embase, and Cochrane Library databases were systematically searched to retrieve studies on the diagnostic efficiency of the CEUS LI-RADS algorithms in diagnosing HCC using SonoVue® and/or Sonazoid® from January 2016 to June 2023. Histopathology or imaging follow-up served as the reference standards. Only articles published in English on retrospective or prospective studies with full reports were included in the meta-analysis. A bivariate random-effects model was used. Data pooling, meta-regression, and sensitivity analysis were performed for the meta-analysis. Deeks' funnel plot asymmetry test was used to evaluate publication bias, and the QUADAS-2 tool was used to assess the methodological quality of eligible studies. Results In total, 26 studies comprising 8,495 patients with 9,244 lesions were included in the meta-analysis. The pooled data results for SonoVue® LI-RADS category 5 (LR-5) and Sonazoid® modified LR-5 were as follows: pooled sensitivity: 0.68 [95% confidence interval (CI): 0.64-0.73, I2=89.20%; P<0.01] and 0.82 (95% CI: 0.74-0.87, I2=85.39%; P<0.01) (P<0.05); pooled specificity: 0.93 (95% CI: 0.90-0.96, I2=86.52%; P<0.01) and 0.86 (95% CI: 0.79-0.91, I2=59.91%; P=0.01) (P<0.05); pooled area under the curve (AUC): 0.86 (95% CI: 0.82-0.89) and 0.91 (95% CI: 0.88-0.93) (P<0.05), respectively. The meta-regression analysis revealed that the study design, subject enrollment method, and reference standard contributed to the heterogeneity of SonoVue® LR-5, and the number of lesions was a source of heterogeneity for Sonazoid® modified LR-5. The diagnostic performance of the LI-RADS category M (LR-M) algorithms of SonoVue® and Sonazoid® was comparable. Conclusions The Sonazoid® modified LR-5 algorithm had a higher diagnostic sensitivity, lower specificity, and higher AUC than SonoVue® LR-5.
Collapse
Affiliation(s)
- Jiazhi Cao
- Department of Medical Ultrasound, West China Hospital of Sichuan University, Chengdu, China
| | - Hong Wang
- Department of Medical Ultrasound, West China Hospital of Sichuan University, Chengdu, China
| | - Wenwu Ling
- Department of Medical Ultrasound, West China Hospital of Sichuan University, Chengdu, China
| |
Collapse
|
6
|
Zhang W, Wang J, Chen L. Characteristics of high frame frequency contrast-enhanced ultrasound in renal tumors. BMC Med Imaging 2024; 24:71. [PMID: 38528467 DOI: 10.1186/s12880-024-01245-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2024] [Accepted: 03/13/2024] [Indexed: 03/27/2024] Open
Abstract
OBJECTIVE This study aims to analyze the characteristics of high frame rate contrast-enhanced ultrasound (H-CEUS) in renal lesions and to improve the ability for differential diagnosis of renal tumors. METHODS A total of 140 patients with renal lesions underwent contrast-enhanced ultrasound (CEUS) examination in the First Affiliated Hospital of Nanchang University from July 2022 to July 2023. Based on the tumor pathology and the results of enhanced CT, tumor patients were divided into malignant and benign groups. All subjects were examined using gray-scale ultrasound, conventional contrast-enhanced ultrasound (C-CEUS), and H-CEUS, and their dynamic images were recorded. Two radiologists independently analyzed and recorded the results of ultrasound, C-CEUS, and H-CEUS images and statistically analyzed the features of C-CEUS and H-CEUS images. The independent sample t-test was used to compare the difference in age and maximum diameter of nodules between the benign and malignant groups. The χ2 test was used to compare the sex, mode of operation, gray-scale ultrasound characteristics, and enhancement characteristics of the two CEUS modes (enhancement mode, regression mode, enhancement degree, enhancement uniformity, enhancement or not, enhancement direction, post-enhancement boundary and range, and pseudocapsule) between the benign and malignant groups. The difference in vascular morphology of malignant nodules of varying sizes under two angiographic modes. RESULTS There were significant differences in gender (χ2 = 10.408, P = 0.001), mode of operation (χ2 = 47.089, P < 0.001), nodule composition (χ2 = 7.481, P = 0.003), nodule echo (χ2 = 20.926, P < 0.001), necrosis (χ2 = 31.343, P < 0.001) and nodule blood flow (χ2 = 9.006, P = 0.029) between the benign and malignant groups. There were significant differences in the regression model (χ2 = 6.782, P = 0.034) and enhancement direction (χ2 = 13.771, P = 0.001) between the two radiographic techniques in the malignant group. There was a significant difference in the enhancement uniformity between the two CEUS techniques in the benign group (χ2 = 8.264, P = 0.004). There was a significant difference between the two CEUS techniques in displaying the vascular morphology in the malignant group with the maximum diameter of nodules ≤ 4.0 cm (χ2 = 11.421, P < 0.022). However, there was no significant difference between the two techniques in the malignant group with the maximum diameter of nodules > 4.0 cm. CONCLUSION Increasing the frame rate of ultrasound images is helpful to accurately display the enhanced features and vascular morphology of renal tumors, especially for malignant tumors with a maximum diameter of ≤ 4.0 cm. Thus, H-CEUS can make up for the limitation of CEUS with regard to the display of vascular morphology.
Collapse
Affiliation(s)
- WeiPing Zhang
- Department of Ultrasound, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China
| | - JingLing Wang
- Department of Ultrasound, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China
| | - Li Chen
- Department of Ultrasound, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China.
| |
Collapse
|
7
|
Villavicencio Kim J, Wu GY. Focal Nodular Hyperplasia: A Comprehensive Review with a Particular Focus on Pathogenesis and Complications. J Clin Transl Hepatol 2024; 12:182-190. [PMID: 38343607 PMCID: PMC10851072 DOI: 10.14218/jcth.2023.00265] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Revised: 09/27/2023] [Accepted: 11/09/2023] [Indexed: 01/03/2025] Open
Abstract
Focal nodular hyperplasia is a benign tumor of the liver that is often found incidentally with imaging. The purpose of this review is to discuss the pathophysiology, rare complications that can occur due to these lesions, and management options. A literature review was performed on clinical trials and case reports involving focal nodular hyperplasia complications and management of these, as well as the proposed pathogenesis underlying these tumors. Although exposure to oral contraceptive pills and endogenous hormones have been thought to play a role in the development of these lesions, this has not been proven. Most recently, they are thought to arise as a consequence of a vascular anomaly causing alterations in the expression of angiopoietin genes. Complications are rare, but previous cases have reported associated pain, rupture and compression of nearby structures (hepatic vein, stomach, biliary system). Resection of focal nodular hyperplasia is not usually recommended. However, if there is associated pain with no other identifiable cause or presence of a large or growing lesion with risk of causing a complication, then surgical resection, radiofrequency ablation or arterial embolization should be considered.
Collapse
Affiliation(s)
- Jaimy Villavicencio Kim
- Division of Gastroenterology-Hepatology, University of Connecticut Health Center, Farmington, CT, USA
| | - George Y. Wu
- Division of Gastroenterology-Hepatology, University of Connecticut Health Center, Farmington, CT, USA
| |
Collapse
|
8
|
Zhang Y, Li Q, Li L, Hong Y, Qiang B, Yu Y, Guo R, Deng H, Han X, Zou X, Guo Z, Zhou J. Diagnostic Performance of Modified Contrast-Enhanced Ultrasound Liver Imaging Reporting and Data System in Patients Without Risk Factors for Hepatocellular Carcinoma: Comparison With World Federation for Ultrasound in Medicine and Biology Guideline. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:243-250. [PMID: 37985306 DOI: 10.1016/j.ultrasmedbio.2023.10.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 10/14/2023] [Accepted: 10/17/2023] [Indexed: 11/22/2023]
Abstract
OBJECTIVE The aim of this study was to assess the ability of the modified contrast-enhanced ultrasound (CEUS) Liver Imaging Reporting and Data System (LI-RADS) to distinguish malignancy in patients without known hepatocellular carcinoma (HCC) risk factors and compare diagnostic accuracy with that of the World Federation for Ultrasound in Medicine and Biology (WFUMB) guideline across radiologists with different levels of CEUS experience. METHODS A total of 848 individuals with no hepatitis infection presenting with 870 lesions in non-cirrhotic livers were included and divided into the Testing and Validation groups. The modified CEUS LI-RADS was proposed, including downgrading of focal nodular hyperplasia with typical features. Diagnostic performance of the modified CEUS LI-RADS was assessed in the Testing group. In the Validation group, two radiologists with more than 9 y of CEUS experience (Experts) and two radiologists with less than 6 mo of CEUS experience (Novices) used both the modified CEUS LI-RADS and the WFUMB guideline to evaluate performance in diagnosis of the lesions. RESULTS LR-5 + M (combination of modified LR-5 and modified LR-M) revealed optimal performance with a sensitivity, specificity and area under the curve (AUC) of 99.3%, 81.6% and 0.904, respectively. Novices using the modified CEUS LI-RADS outperformed those using the WFUMB guideline (AUC: 0.858 vs. 0.767, p = 0.005). Additionally, the sensitivity, specificity and AUC of Novices were comparable to those of Experts using the modified CEUS LI-RADS (94.1%, 77.6% and 0.858 vs. 96.1%, 77.6% and 0.868 for experts, respectively). CONCLUSION The modified CEUS LI-RADS is a valuable method for distinguishing hepatic malignancy in patients without HCC risk factors. This is particularly beneficial for radiologists with limited CEUS expertise.
Collapse
Affiliation(s)
- Yafang Zhang
- Department of Ultrasound, State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Qing Li
- Department of Ultrasound, State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Lingling Li
- Department of Ultrasound, State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Yong Hong
- Department of Ultrasound, Zhongshan Dongfeng People's Hospital, Zhongshan, China
| | - Banghong Qiang
- Department of Ultrasound Medicine, Wuhu Hospital, East China Normal University (The Second People's Hospital), Wuhu, China
| | - Yiwen Yu
- Department of Ultrasound, State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Ruohan Guo
- Department of Ultrasound, State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Hanxia Deng
- Department of Ultrasound, State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Xu Han
- Department of Ultrasound, State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Xuebin Zou
- Department of Ultrasound, State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Zhixing Guo
- Department of Ultrasound, State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Jianhua Zhou
- Department of Ultrasound, State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, China.
| |
Collapse
|
9
|
Zhu L, Li N, Zhu Y, Han P, Jiang B, Li M, Luo Y, Clevert DA, Fei X. Value of high frame rate contrast enhanced ultrasound in gallbladder wall thickening in non-acute setting. Cancer Imaging 2024; 24:7. [PMID: 38191513 PMCID: PMC10775603 DOI: 10.1186/s40644-023-00651-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Accepted: 12/25/2023] [Indexed: 01/10/2024] Open
Abstract
BACKGROUND Ultrasound (US) has been widely used in screening and differential diagnosis of gallbladder wall thickening (GWT). However, the sensitivity and specificity for diagnosing wall-thickening type gallbladder cancer are limited, leading to delayed treatment or overtreatment. We aim to explore the value of high frame rate contrast enhanced ultrasound (H-CEUS) in distinguishing wall-thickening type gallbladder cancer (malignant) from GWT mimicking malignancy (benign). METHODS This retrospective study enrolled consecutive patients with non-acute GWT who underwent US and H-CEUS examination before cholecystectomy. Clinical information, US image and H-CEUS image characteristics between malignant and benign GWT were compared. The independent risk factors for malignant GWT on H-CEUS images were selected by multivariate logistic regression analysis. The diagnostic performance of H-CEUS in determining malignant GWT was compared with that of the gallbladder reporting and data system (GB-RADS) score. RESULTS Forty-six patients included 30 benign GWTs and 16 malignant GWTs. Only mural layering and interface with liver on US images were significantly different between malignant and benign GWT (P < 0.05). Differences in enhancement direction, vascular morphology, serous layer continuity, wash-out time and mural layering in the venous phase of GWT on H-CEUS images were significant between malignant and benign GWT (P < 0.05). The sensitivity, specificity and accuracy of H-CEUS based on enhancement direction, vascular morphology and wash-out time in the diagnosis of malignant GWT were 93.75%, 90.00%, and 91.30%, respectively. However, the sensitivity, specificity and accuracy of the GB-RADS score were only 68.75%, 73.33% and 71.74%, respectively. The area under ROC curve (AUC) of H-CEUS was significantly higher than that of the GB-RADS score (AUC = 0.965 vs. 0.756). CONCLUSIONS H-CEUS can accurately detect enhancement direction, vascular morphology and wash-out time of GWT, with a higher diagnostic performance than the GB-RADS score in determining wall-thickening type gallbladder cancer. This study provides a novel imaging means with high accuracy for the diagnosis of wall-thickening type gallbladder cancer, thus may be better avoiding delayed treatment or overtreatment.
Collapse
Affiliation(s)
- Lianhua Zhu
- Department of Ultrasound, the First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Nan Li
- Department of Ultrasound, the First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Yaqiong Zhu
- Department of Ultrasound, the First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Peng Han
- Department of Ultrasound, the First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Bo Jiang
- Department of Ultrasound, the First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Miao Li
- Department of Ultrasound, the First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Yukun Luo
- Department of Ultrasound, the First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Dirk-André Clevert
- Department of Clinical Radiology, Interdisciplinary Ultrasound-Center, University of Munich, Grosshadern Campus, Munich, Germany.
| | - Xiang Fei
- Department of Ultrasound, the First Medical Center, Chinese PLA General Hospital, Beijing, China.
| |
Collapse
|
10
|
Giangregorio F, Garolfi M, Mosconi E, Ricevuti L, Debellis MG, Mendozza M, Esposito C, Vigotti E, Cadei D, Abruzzese D. High frame-rate contrast enhanced ultrasound (HIFR-CEUS) in the characterization of small hepatic lesions in cirrhotic patients. J Ultrasound 2023; 26:71-79. [PMID: 36227456 PMCID: PMC10063709 DOI: 10.1007/s40477-022-00724-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Accepted: 08/22/2022] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND To show the effectiveness of plane wave HighFrame-Rate CEUS (HiFR-CEUS) compared with "conventional" (plane wave) CEUS (C-CEUS) in the characterization of small (< 2 cm) focal liver lesions (FLLs) not easily detected by CT in cirrhotic patients. HiFR-CEUS exploit an ultra-wideband nonlinear process to combine fundamental, second and higher-order harmonic signals generated by ultrasound contrast agents to increase the frame rate. C-CEUS is limited by the transmission principle, and its frame-rate is around 10 FPS. With HiFR-CEUS (Shenzhen Mindray Bio-Medical Electronics Co., China), the frame-rate reached 60 FPS. MATERIAL AND METHODS Ultrasound detected small FLLs (< 2 cm) in 63 cirrhotic patients during follow-up (June 2019-February 2020); (7 nodules < 1 cm and were not evaluable by spiral CT). Final diagnosis was obtained with MRI (47) or fine needle aspiration (16 cases) C-CEUS was performed and HiFR-CEUS was repeated after 5 min; 0.8-1.2 ml of contrast media (SonoVue, Bracco, Italy) was used. 57 nodules were better evaluable with HiFR-CEUS; 6 nodules were equally evaluable by both techniques; final diagnosis was: 44 benign lesions (29 hemangiomas, 1 amartoma, 2 hepatic cysts; 2 focal nodular hyperplasias, 3 regenerative macronodules, 3 AV-shunts, 3 hepatic sparing areas and 1 focal steatosis) and 19 malignant one (17 HCCs, 1 cholangioca, 1 metastasis); statistical evaluation for better diagnosis with X2 test (SPSS vers. 26); we used LI-RADS classification for evaluating sensitivity, specificity PPV, NPV and diagnostic accuracy of C- and HFR-CEUS. Corrispective AU-ROC were calculated. RESULTS C-CEUS and HiFR-CEUS reached the same diagnosis in 29 nodules (13 nodules > 1 < 1.5 cm; 16 nodules > 1.5 < 2 cm); HiFR-CEUS reached a correct diagnosis in 32 nodules where C-CEUS was not diagnostic (6 nodules < 1 cm; 17 nodules > 1 < 1.5 cm; 9 nodules > 1.5 < 2 cm); C-CEUS was better in 2 nodules (1 < 1 cm and 1 > 1 < 1.5 cm). Some patient's (sex, BMI, age) and nodule's characteristics (liver segment, type of diagnosis, nodule's dimensions (p = 0.65)) were not correlated with better diagnosis (p ns); only better visualization (p 0.004) was correlated; C-CEUS obtained the following LI-RADS: type-1: 18 Nodules, type-2: 21; type-3: 7, type-4: 7; type-5: 8; type-M: 2; HiFR-CEUS: type-1: 38 Nodules, type-2: 2; type-3:4, type-4: 2; type-5: 15; type-M: 2; In comparison with final diagnosis: C-CEUS: TP: 17; TN: 39; FP: 5; FN:2; HIFR-CEUS: TP: 18; TN: 41; FP: 3; FN:1; C-CEUS: sens: 89.5%; Spec: 88.6%, PPV: 77.3%; NPV: 95.1%; Diagn Acc: 88.6% (AU-ROC: 0.994 ± SEAUC: 0.127; CI: 0.969-1.019); HiHFR CEUS: sens: 94.7%; Spec: 93.2%, PPV: 85.7%; NPV: 97.6%; Diagn Acc: 93.2% (AU-ROC: 0.9958 ± SEAUC: 0.106; CI: 0.975-1.017) FLL vascularization in the arterial phase was more visible with HiFR-CEUS than with C-CEUS, capturing the perfusion details in the arterial phase due to a better temporal resolution. With a better temporal resolution, the late phase could be evaluated longer with HiFR-CEUS (4 min C-CEUS vs. 5 min HiFR-CEUS). CONCLUSION Both C-CEUS and HIFR-CEUS are good non invasive imaging system for the characterization of small lesions detected during follow up of cirrhotic patients. HiFR-CEUS allowed better FLL characterization in cirrhotic patients with better temporal and spatial resolution capturing the perfusion details that cannot be easily observed with C-CEUS.
Collapse
Affiliation(s)
| | - M Garolfi
- Ospedale Civico di Codogno, Lodi, Italy
| | - E Mosconi
- Ospedale Civico di Codogno, Lodi, Italy
| | | | | | | | | | - E Vigotti
- Ospedale Civico di Codogno, Lodi, Italy
| | - D Cadei
- Ospedale Civico di Codogno, Lodi, Italy
| | | |
Collapse
|