Jang SW, Lee SH, Shin HK, Jeon SR, Roh SW, Park JH. Management of Cerebrospinal Fluid Leakage by Pump-Regulated Volumetric Continuous Lumbar Drainage Following Anterior Cervical Decompression and Fusion for Ossification of the Posterior Longitudinal Ligament.
Neurospine 2023;
20:1421-1430. [PMID:
38171308 PMCID:
PMC10762383 DOI:
10.14245/ns.2346736.368]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Revised: 08/05/2023] [Accepted: 08/28/2023] [Indexed: 01/05/2024] Open
Abstract
OBJECTIVE
Cerebrospinal fluid (CSF) leakage is a major concern related to anterior cervical decompression and fusion for ossification of the posterior longitudinal ligament (OPLL). We propose a management algorithm for CSF leakage following anterior cervical decompression and fusion for OPLL involving the use of pump-regulated volumetric continuous lumbar drainage.
METHODS
We retrospectively reviewed patients who underwent anterior cervical decompression and fusion for OPLL and were managed with the proposed algorithm between March 2018 and July 2022. The proposed management algorithm for CSF leakage by pump-regulated volumetric continuous lumbar drainage was as follows. On exposure of the arachnoid membrane with or without CSF leakage, a dural sealant patch was applied to manage the dural defect. In case of persistent CSF leakage despite application of the dural sealant patch, patients underwent pump-regulated volumetric continuous lumbar drainage.
RESULTS
Fifty-one patients were included in the study. CSF leakage occurred in 14 patients. Of these 14 patients, 9 patients underwent lumbar drain insertion according to the proposed management algorithm. Successful resolution of CSF leakage was observed in 8 of the 9 patients who underwent lumbar drainage. All patients were encouraged to ambulate without concern of CSF overdrainage due to gravity, because it could be avoided with pump-regulated volumetric continuous CSF drainage. Therefore, complications associated with absolute bed rest or CSF overdrainage were not observed.
CONCLUSION
The proposed management algorithm with pump-regulated volumetric continuous lumbar drainage showed safety and efficacy for management of CSF leakage following anterior decompression and fusion for OPLL.
Collapse