• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4616374)   Today's Articles (686)   Subscriber (49394)
For: Ryu H, Ahn SJ, Yoon JH, Lee JM. Reproducibility of liver stiffness measurements made with two different 2-dimensional shear wave elastography systems using the comb-push technique. Ultrasonography 2018;38:246-254. [PMID: 30744303 PMCID: PMC6595128 DOI: 10.14366/usg.18046] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2018] [Accepted: 11/23/2018] [Indexed: 12/12/2022]  Open
Number Cited by Other Article(s)
1
Coelho M, Fernandes F, Cardoso SW, Piedade J, Torres da Silva MV, Santos R, Veloso VG, Grinsztejn B, Pereira GH, Perazzo H. Accuracy and concordance of two-dimensional shear-wave elastography using transient elastography as the reference in chronic viral hepatitis and HIV infection in Rio de Janeiro, Brazil. Eur J Gastroenterol Hepatol 2023;35:583-590. [PMID: 36966773 DOI: 10.1097/meg.0000000000002537] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/30/2023]
2
Xiang H, Ling W, Ma L, Yang L, Lin T, Luo Y. Shear wave elastography using sound touch elastography and supersonic shear imaging for liver measurements: a comparative study. Quant Imaging Med Surg 2022;12:2855-2865. [PMID: 35502377 PMCID: PMC9014163 DOI: 10.21037/qims-21-863] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Accepted: 01/19/2022] [Indexed: 08/26/2023]
3
Yoo JJ, Kim SG, Kim YS. The Diagnostic Accuracy of LOGIQ S8 and E9 Shear Wave Elastography for Staging Hepatic Fibrosis, in Comparison with Transient Elastography. Diagnostics (Basel) 2021;11:diagnostics11101817. [PMID: 34679515 PMCID: PMC8535143 DOI: 10.3390/diagnostics11101817] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Revised: 09/24/2021] [Accepted: 09/27/2021] [Indexed: 12/12/2022]  Open
4
Li Y, Wu S. Liver stiffness measured with two-dimensional shear wave elastography comparable to histopathology falls dominantly on the severe liver fibrosis. Clin Hemorheol Microcirc 2021;79:587-596. [PMID: 34334386 DOI: 10.3233/ch-211223] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
5
Refraction artifact on abdominal sonogram. J Med Ultrason (2001) 2021;48:273-283. [PMID: 34021821 DOI: 10.1007/s10396-021-01097-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Accepted: 04/12/2021] [Indexed: 02/06/2023]
6
Lim Z, Whitaker T, DeColle K, Barrett K, Harlton C, Paskar L, Low G. Interobserver and Intraobserver Reliability of Hepatic Shear Wave Elastography and the Influence of Fasted Versus Nonfasted States in Healthy Volunteers. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2021;40:259-267. [PMID: 32686849 DOI: 10.1002/jum.15395] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Revised: 05/25/2020] [Accepted: 05/30/2020] [Indexed: 06/11/2023]
7
Naganuma H, Ishida H, Uno A, Nagai H, Kuroda H, Ogawa M. Diagnostic problems in two-dimensional shear wave elastography of the liver. World J Radiol 2020;12:76-86. [PMID: 32549956 PMCID: PMC7288776 DOI: 10.4329/wjr.v12.i5.76] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Revised: 05/06/2020] [Accepted: 05/13/2020] [Indexed: 02/06/2023]  Open
8
Lee J, Kang HJ, Yoon JH, Lee JM. Ultrasound-guided transient elastography and two-dimensional shear wave elastography for assessment of liver fibrosis: emphasis on technical success and reliable measurements. Ultrasonography 2020;40:217-227. [PMID: 32660200 PMCID: PMC7994746 DOI: 10.14366/usg.20036] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Accepted: 05/16/2020] [Indexed: 12/23/2022]  Open
9
Alrashed AI, Alfuraih AM. Reproducibility of shear wave elastography among operators, machines, and probes in an elasticity phantom. Ultrasonography 2020;40:158-166. [PMID: 32660213 PMCID: PMC7758105 DOI: 10.14366/usg.20011] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2020] [Accepted: 05/09/2020] [Indexed: 12/28/2022]  Open
10
Ko A, Lee ES, Park HJ, Park SB, Kim HS, Choi BI. Added value of 2D shear wave imaging of the gallbladder bed of the liver for acute cholecystitis. Ultrasonography 2020;39:384-393. [PMID: 32962334 PMCID: PMC7515659 DOI: 10.14366/usg.19060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2019] [Accepted: 03/23/2020] [Indexed: 12/07/2022]  Open
11
Osman AM, El Shimy A, Abd El Aziz MM. 2D shear wave elastography (SWE) performance versus vibration-controlled transient elastography (VCTE/fibroscan) in the assessment of liver stiffness in chronic hepatitis. Insights Imaging 2020;11:38. [PMID: 32152802 PMCID: PMC7062958 DOI: 10.1186/s13244-020-0839-y] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Accepted: 01/30/2020] [Indexed: 12/16/2022]  Open
12
Lee SM, Kim MJ, Yoon JH, Hong W, Ha HI, Lee K, Choe JY, Lee JW, Yoon SY, Han J. Comparison of point and 2-dimensional shear wave elastography for the evaluation of liver fibrosis. Ultrasonography 2020;39:288-297. [PMID: 32311869 PMCID: PMC7315295 DOI: 10.14366/usg.19090] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Accepted: 03/06/2020] [Indexed: 12/20/2022]  Open
13
Petzold G, Grieme B, Bremer SCB, Knoop RF, Goetze RG, Ellenrieder V, Kunsch S, Neesse A. Prospective comparison of 2D-shearwave elastography in both liver lobes in healthy subjects and in patients with chronic liver disease. Scand J Gastroenterol 2019;54:1138-1145. [PMID: 31433262 DOI: 10.1080/00365521.2019.1653961] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA