1
|
Langdon J, Sharbidre K, Garner MS, Robbin M, Scoutt LM. Renal transplant ultrasound: assessment of complications and advanced applications. Abdom Radiol (NY) 2024:10.1007/s00261-024-04731-9. [PMID: 39643733 DOI: 10.1007/s00261-024-04731-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2024] [Revised: 11/24/2024] [Accepted: 11/26/2024] [Indexed: 12/09/2024]
Abstract
Renal transplantation is the most commonly performed solid organ transplant procedure. Monitoring renal transplants with ultrasound is a critical component in the management of transplant patients both in the immediate aftermath of surgery and longitudinally. Many complications are detectable via ultrasound evaluation with relative prevalence dependent on the time since surgery. It is critical for the practicing radiologist to recognize these complications to help guide appropriate treatment. Fundamental understanding of the procedure, including various surgical techniques is of great importance. In this article, the sonographic findings of the most common postoperative and long-term complications of renal transplantation are reviewed. As complications are highly related to surgical technique, the most common surgical techniques are presented first. Comprehensive ultrasound evaluation of the allograft is discussed next, followed by extensive review of the ultrasound findings of common complications. Finally, select recent advances in ultrasound are presented with their current and potential applications to renal transplant evaluation.
Collapse
Affiliation(s)
- Jonathan Langdon
- Department of Radiology & Biomedical Imaging, Yale School of Medicine, New Haven, CT, USA.
| | - Kedar Sharbidre
- Department of Radiology, University of Alabama at Birmingham, Birmingham, USA
| | - Matthew S Garner
- Department of Surgery, SUNY Upstate Medical University, Syracuse, USA
| | - Michelle Robbin
- Department of Radiology, University of Alabama at Birmingham, Birmingham, USA
| | - Leslie M Scoutt
- Department of Radiology & Biomedical Imaging, Yale School of Medicine, New Haven, CT, USA
| |
Collapse
|
2
|
Kim J, Kamiyama N, Tanigawa S, Yoon H, Lim HJ, Lee MJ. Application of a quality threshold to improve liver shear wave elastography measurements in free-breathing pediatric patients. Ultrasonography 2024; 43:354-363. [PMID: 39112092 PMCID: PMC11374582 DOI: 10.14366/usg.24054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2024] [Accepted: 07/07/2024] [Indexed: 09/04/2024] Open
Abstract
PURPOSE This study assessed the benefits of quality threshold (QT) implementation for liver shear wave elastography (SWE) in children during free breathing. METHODS The QT, which adjusts the SWE map display based on shear wave quality, was set at 55%. Phantom measurements (PMs) were taken with a fixed probe using QT (termed PM-1); a moving probe without QT (PM-2); and a moving probe with QT (PM-3). Each measurement was subjected to random samplings of various sizes. Clinical measurements (CMs) were obtained from children with biliary atresia using following protocols: CM-1, manually defined regions of interest (ROIs); CM-2, default ROIs without QT; and CM-3, default ROIs with QT. Elasticity measurements were compared across fibrosis grades, and color patterns on the SWE maps were analyzed. RESULTS In the phantom experiments, the moving probe produced lower elasticity measurements; this difference decreased upon QT application. With the moving probe, random sampling indicated fewer interquartile range-to-median ratios exceeding 30% upon QT application (4% vs. 14% when five values were sampled, P=0.004). In clinical experiments, QT improved the differentiation of fibrosis grade in patients over 5 years old, with a significant difference between moderate and severe fibrosis (P=0.004). Elasticity variability was positively correlated with fibrosis grade (τ=0.376, P<0.001). Certain apparent errors, termed artificial stripe patterns, were not eliminated by QT. CONCLUSION Applying QT to exclude low-quality pixels can minimize measurement error and improve differentiation of liver fibrosis grades. The presence of an artificial stripe pattern on the SWE map may indicate images requiring exclusion.
Collapse
Affiliation(s)
- Jisoo Kim
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | | | | | - Haesung Yoon
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Hyun Ji Lim
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Mi-Jung Lee
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
3
|
Leong SS, Wong JHD, Rozalli FI, Yahya F, Tee YC, Yamin LSM, Razalli MM, Baharuddin H. 2D shear wave elastography for the assessment of quadriceps entheses-a methodological study. Skeletal Radiol 2024; 53:455-463. [PMID: 37594519 DOI: 10.1007/s00256-023-04425-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 08/04/2023] [Accepted: 08/04/2023] [Indexed: 08/19/2023]
Abstract
OBJECTIVE To establish the scanning protocol for 2-dimensional shear wave elastography (SWE) on normal entheses by investigating the possible confounding factors that may increase the variability of measured elasticity. MATERIAL AND METHODS 30 normal quadriceps entheses were scanned using SWE to compare the stiffness and coefficient variation by changing the ultrasonic coupling gel thickness, knee position, region of interest size, and scanning plane. RESULTS No significant difference in median shear wave velocity (SWV) was observed in different coupling gel thicknesses. The median SWV was higher in the knee flexion position than in the extended position (p < 0.001). Increased knee flexion led to stiffer quadriceps enthesis and higher SWV (ρ = 0.8, p < 0.001). The median SWV was higher when the diameter region of interest was 4.0 mm than 2.0 mm (p = 0.001). The median SWV was higher in the transverse plane than in the longitudinal plane (p < 0.001). Strong correlation was found between SWV and the degree of the shear wave to muscle fiber direction (ρ = 0.8, p < 0.001). The coefficient variation was lower in a gel thickness of 2.5 cm, with an extended knee, a region of interest of 2.0 mm, and a longitudinal plane (p > 0.05). For interobserver reliability for the proposed protocol, the intraclass correlation coefficients was 0.763. CONCLUSION In this study, we determined supine position with the knee extended; using 2.0 mm diameter region of interest and image acquisition at the longitudinal plane with thicker layer coupling gel seems most appropriate to reliably image healthy quadriceps entheses with SWE.
Collapse
Affiliation(s)
- Sook Sam Leong
- Centre for Medical Imaging Studies, Faculty of Health Sciences, Universiti Teknologi MARA, 42300, Selangor, Malaysia.
| | - Jeannie Hsiu Ding Wong
- Department of Biomedical Imaging, Faculty of Medicine, Universiti Malaya, 50603, Kuala Lumpur, Malaysia
| | - Faizatul Izza Rozalli
- Department of Biomedical Imaging, Faculty of Medicine, Universiti Malaya, 50603, Kuala Lumpur, Malaysia
| | - Fariz Yahya
- Department of Medicine, Faculty of Medicine, Rheumatology Unit, Universiti Malaya, 50603, Kuala Lumpur, Malaysia
| | - Ying Chew Tee
- Department of Medicine, Faculty of Medicine, Rheumatology Unit, Universiti Malaya, 50603, Kuala Lumpur, Malaysia
| | - Lyana Shahirah Mohamad Yamin
- Centre for Medical Imaging Studies, Faculty of Health Sciences, Universiti Teknologi MARA, 42300, Selangor, Malaysia
| | - Mazuin Mohd Razalli
- Department of Radiology, Faculty of Medicine, Universiti Teknologi MARA, 47000, Sungai Buloh, Malaysia
| | - Hazlyna Baharuddin
- Department of Internal Medicine, Faculty of Medicine, Rheumatology Unit, UniversitiTeknologi MARA, 47000, Sungai Buloh, Malaysia
| |
Collapse
|
4
|
Cè M, Felisaz PF, Alì M, Re Sartò GV, Cellina M. Ultrasound elastography in chronic kidney disease: a systematic review and meta-analysis. J Med Ultrason (2001) 2023; 50:381-415. [PMID: 37186192 DOI: 10.1007/s10396-023-01304-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Accepted: 03/07/2023] [Indexed: 05/17/2023]
Abstract
Ultrasound elastography (USE) is a noninvasive technique for assessing tissue elasticity, and its application in nephrology has aroused growing interest in recent years. The purpose of this article is to systematically review the clinical application of USE in patients with chronic kidney disease (CKD), including native and transplanted kidneys, and quantitatively investigate differences in elasticity values between healthy individuals and CKD patients. Furthermore, we provide a qualitative analysis of the studies included, discussing the potential interplay between renal stiffness, estimated glomerular filtration rate, and fibrosis. In January 2022, a systematic search was carried out on the MEDLINE (PubMed) database, concerning studies on the application of USE in patients with CKD, including patients with transplanted kidneys. The results of the included studies were extracted by two independent researchers and presented mainly through a formal narrative summary. A meta-analysis of nine study parts from six studies was performed. A total of 647 studies were screened for eligibility and, after applying the exclusion and inclusion criteria, 69 studies were included, for a total of 6728 patients. The studies proved very heterogeneous in terms of design and results. The shear wave velocity difference of - 0.82 m/s (95% CI: - 1.72-0.07) between CKD patients and controls was not significant. This result agrees with the qualitative evaluation of included studies that found controversial results for the relationship between renal stiffness and glomerular filtration rate. On the contrary, a clear relationship seems to emerge between USE values and the degree of fibrosis. At present, due to the heterogeneity of results and technical challenges, large-scale application in the monitoring of CKD patients remains controversial.
Collapse
Affiliation(s)
- Maurizio Cè
- Postgraduate School in Diagnostic and Interventional Radiology, University of Milan, Milan, Italy.
| | - Paolo Florent Felisaz
- Division of Radiology, ASST Fatebenefratelli Sacco, Fatebenefratelli Hospital, Milan, Italy
| | - Marco Alì
- Centro Diagnostico Italiano, Milan, Italy
- Bracco Imaging S.P.A., Milan, Italy
| | - Giulia Vanessa Re Sartò
- Division of Nephrology and Dialysis, ASST Fatebenefratelli Sacco, Fatebenefratelli Hospital, Milan, Italy
| | - Michaela Cellina
- Division of Radiology, ASST Fatebenefratelli Sacco, Fatebenefratelli Hospital, Milan, Italy
| |
Collapse
|
5
|
Lee SM, Ha HI, Lee IJ, Lee K, Lee JW, Park JW, Kim SE, Kwon MJ, Choe JY, Yoon SY, Yeo SG, Kim MJ. Comparison between Two-Dimensional and Point Shear Wave Elastography Techniques in Evaluating Liver Fibrosis Using Histological Staging as the Reference Standard: A Prospective Pilot Study. Diagnostics (Basel) 2023; 13:diagnostics13091646. [PMID: 37175039 PMCID: PMC10178401 DOI: 10.3390/diagnostics13091646] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 05/02/2023] [Accepted: 05/05/2023] [Indexed: 05/15/2023] Open
Abstract
Evaluation of hepatic fibrosis is essential to prevent liver-related morbidity and mortality. Although various types of ultrasound shear wave elastography (SWE) have been used and validated, there are limited studies on the relatively newer technique, two-dimensional SWE (2D-SWE). Therefore, this study aimed to compare the diagnostic performances of 2D-SWE and point SWE (p-SWE) for evaluating liver fibrosis using histology as the reference standard. To measure liver stiffness (LS) values, 87 patients underwent 2D-SWE and p-SWE using the same machine. Technical failures and unreliable measurements were also evaluated. The diagnostic performances of 2D-SWE and p-SWE were compared using area under the receiver operating characteristic (AUROC) curve analysis. No technical failures were observed in either method; however, unreliable measurements were less frequent in 2D-SWE (1/87 [1.1%]) than in p-SWE (8/87 [9.2%]) (p < 0.001). The AUROC of the LS values of 2D-SWE were significantly higher than those of p-SWE for diagnosing significant fibrosis (0.965 vs. 0.872, p = 0.022) and cirrhosis (0.994 vs. 0.886, p = 0.042). In conclusion, 2D-SWE is more reliable and accurate than p-SWE for diagnosing hepatic fibrosis.
Collapse
Affiliation(s)
- Sang Min Lee
- Department of Radiology, CHA University Gangnam Medical Center, Seoul 06135, Republic of Korea
| | - Hong Il Ha
- Department of Radiology, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang 14068, Republic of Korea
| | - In Jae Lee
- Department of Radiology, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang 14068, Republic of Korea
| | - Kwanseop Lee
- Department of Radiology, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang 14068, Republic of Korea
| | - Jung Woo Lee
- Department of Surgery, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang 14068, Republic of Korea
| | - Ji Won Park
- Department of Internal Medicine, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang 14068, Republic of Korea
| | - Sung-Eun Kim
- Department of Internal Medicine, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang 14068, Republic of Korea
| | - Mi Jung Kwon
- Department of Pathology, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang 14068, Republic of Korea
| | - Ji-Young Choe
- Anatomic Pathology Reference Lab, Seegene Medical Foundation, Seoul 04805, Republic of Korea
| | - Sam-Youl Yoon
- Department of Surgery, Inje University Sanggye Paik Hospital, Seoul 01757, Republic of Korea
| | - Seung-Gu Yeo
- Department of Radiation Oncology, Soonchunhyang University College of Medicine, Soonchunhyang University Hospital, Bucheon 14584, Republic of Korea
| | - Min-Jeong Kim
- Department of Radiology, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang 14068, Republic of Korea
| |
Collapse
|
6
|
Leong SS, Jalalonmuhali M, Md Shah MN, Ng KH, Vijayananthan A, Hisham R, Wong JHD. Ultrasound shear wave elastography for the evaluation of renal pathological changes in adult patients. Br J Radiol 2023; 96:20220288. [PMID: 36802861 PMCID: PMC10078884 DOI: 10.1259/bjr.20220288] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Revised: 08/10/2022] [Accepted: 02/06/2023] [Indexed: 02/22/2023] Open
Abstract
OBJECTIVE Many studies have conflicting findings in using shear wave elastography (SWE) to assess renal fibrosis. This study reviews the use of SWE to evaluate pathological changes in native kidneys and renal allografts. It also tries to elucidate the confounding factors and care taken to ensure the results are consistent and reliable. METHODS The review was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. Literature search was conducted in Pubmed, Web of Science and Scopus database up to 23 October 2021. To evaluate risk and bias applicability, the Cochrane risk-of bias tool and GRADE was used. The review was registered under PROSPERO CRD42021265303. RESULTS A total of 2921 articles were identified. 104 full texts were examined and 26 studies included in systematic review. 11 studies performed on native kidneys and 15 studies on transplanted kidney. A wide range of impact factors was found that affect the accuracy of SWE of renal fibrosis in adult patients. CONCLUSIONS Compared to point SWE, two-dimensional SWE with elastogram could enable better selection of the region of interest in kidneys, leading to reproducible results. Tracking waves were attenuated as the depth from skin to region of interest increased, therefore, SWE is not recommended for overweight or obese patients. Variable transducer forces might also affect SWE reproducibility, thus, training of operators to ensure consistent operator-dependent transducer forces may be helpful. ADVANCES IN KNOWLEDGE This review provides a holistic insight on the efficiency of using SWE in evaluating pathological changes in native and transplanted kidneys, thereby contributing to the knowledge of its utilisation in clinical practice.
Collapse
Affiliation(s)
- Sook Sam Leong
- Centre for Medical Imaging Studies, Faculty of Health Sciences, Universiti Teknologi MARA, Selangor, Malaysia
| | | | - Mohammad Nazri Md Shah
- Department of Biomedical Imaging, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia
| | | | | | - Ranitha Hisham
- University Malaya Library, Universiti Malaya, Kuala Lumpur, Malaysia
| | - Jeannie Hsiu Ding Wong
- Department of Biomedical Imaging, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia
| |
Collapse
|
7
|
Fang C, Rafailidis V, Konstantatou E, Yusuf GT, Barrow I, Pagkalidou E, Romanos O, Agarwal K, Quaglia A, Sidhu PS. Comparison Between Different Manufacturers' 2-D and Point Shear Wave Elastography Techniques in Staging Liver Fibrosis in Chronic Liver Disease Using Liver Biopsy as the Reference Standard: A Prospective Study. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:2229-2236. [PMID: 36008215 DOI: 10.1016/j.ultrasmedbio.2022.06.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 05/04/2022] [Accepted: 06/12/2022] [Indexed: 06/15/2023]
Abstract
The purpose of this study was to assess the utility of 2-D shear wave elastography (SWE) in assessing liver fibrosis in patients with chronic liver disease by comparing its performance with that of point shear wave elastography (pSWE) using liver histological staging as the reference standard. In this ethics committee-approved, single-institution prospective study, pSWE and 2-D SWE velocity measurements were obtained in 121 adult patients (age: 18-70 y, median: 45 y) immediately before a liver biopsy for chronic liver disease. Shear wave velocity (SWV) and Ishak scores were compared using the Kruskal-Wallis test, Spearman's correlation and receiver operating characteristic (ROC) curve analysis. Youden's index was used to determine the optimal cutoff point. There was no technical failure using pSWE and 2-D SWE. The mean difference for SWV between pSWE and 2-D SWE was 0.0223 (limits of agreement: -1.1009, 1.1145). Values for both pSWE and 2-D SWE were significantly correlated with fibrosis stage (Spearman's ρ = 0.606, p < 0.0001; ρ = 0.722, p < 0.001 respectively). The area under the ROC curve differentiating F ≥3 was 0.855 (95% confidence interval: 0.778-0.932) for pSWE and 0.884 (95% CI: 0.817-0.951) for 2-D SWE. The AUC for differentiating F ≥5 was 0.890 (95% CI: 0.826-0.954) for pSWE and 0.926 (95% CI: 0.88-0.973) for 2-D SWE. This study indicates that 2-D SWE provides feasible and accurate assessment of liver fibrosis, comparable to that provided by pSWE from two different manufacturers' machines.
Collapse
Affiliation(s)
- Cheng Fang
- Department of Radiology, King's College Hospital NHS Foundation Trust, London, UK.
| | - Vasileios Rafailidis
- Department of Radiology, King's College Hospital NHS Foundation Trust, London, UK
| | - Eleni Konstantatou
- Department of Radiology, King's College Hospital NHS Foundation Trust, London, UK
| | - Gibran T Yusuf
- Department of Radiology, King's College Hospital NHS Foundation Trust, London, UK
| | - Ian Barrow
- Department of Radiology, King's College Hospital NHS Foundation Trust, London, UK
| | - Eirini Pagkalidou
- Department of Hygiene, Social-Preventive Medicine and Medical Statistics, School of Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Odyssefs Romanos
- Department of Radiology, King's College Hospital NHS Foundation Trust, London, UK
| | - Kosh Agarwal
- Institute of Liver Studies, King's College Hospital NHS Foundation Trust, London, SE5 9RS, United Kingdom
| | - Alberto Quaglia
- Institute of Liver Studies, King's College Hospital NHS Foundation Trust, London, SE5 9RS, United Kingdom; Department of Cellular Pathology, Royal Free London NHS Foundation Trust, London, UK; UCL Cancer Institute, University College London, London, UK
| | - Paul S Sidhu
- Department of Radiology, King's College Hospital NHS Foundation Trust, London, UK
| |
Collapse
|
8
|
Sultan SR, Alghamdi A, Abdeen R, Almutairi F. Evaluation of ultrasound point shear wave elastography reliability in an elasticity phantom. Ultrasonography 2022; 41:291-297. [PMID: 35316890 PMCID: PMC8942736 DOI: 10.14366/usg.21114] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2021] [Accepted: 07/31/2021] [Indexed: 12/31/2022] Open
Abstract
PURPOSE To date, limited studies have specifically addressed the reliability of ultrasound point shear-wave elastography (pSWE). Therefore, the aim of the present study was to assess the reproducibility of ultrasound pSWE within and between operators using two ultrasound scanners. METHODS iU22 and EPIQ7 ultrasound scanners were used to assess the reliability of pSWE measurements of four inclusions [L I (8 kPa), L II (14 kPa), L III (48 kPa), and L IV (80 kPa)] at a depth of 3.5 cm in an elasticity phantom using a curvilinear 5-1 MHz transducer. The intraoperator, inter-operator, and inter-scanner reproducibility of pSWE was assessed using intraclass correlation coefficients (ICCs). Bland-Altman plots were used to establish bias and limits of agreement (LoA) between measurements. The accuracy of pSWE from manufacturer values was determined using the one-sample t-test. RESULTS Intra-operator agreement was excellent, with an ICC >0.90. The bias in measurements for operator A was -0.36±3.13 kPa (LoA, -6.47 to 5.75), and for operator B it was 1.97±6.29 kPa (LoA, -10.25 to 14.21). Inter-operator agreement was excellent, with an ICC of 0.95. The bias in measurements between operators was -0.42±5.00 kPa (LoA, -10.24 to 9.38). The inter-scanner agreement between EPIQ7 and iU22 was excellent, with an ICC of 0.96. The bias in measurements between scanners was 1.74±4.44 kPa (LoA, -6.95 to 10.45). There was significant overestimation for L I (17.75%) and L II (31.14%) and underestimation for L III (-15.28%) and L VI (-98.00%) relative to the manufacturer-reported values. CONCLUSION Phantom ultrasound pSWE was reproducible within and between operators, and between Philips ultrasound scanners; further studies using different ultrasound systems and transducers are required.
Collapse
Affiliation(s)
- Salahaden R Sultan
- Department of Diagnostic Radiology, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Amer Alghamdi
- Department of Diagnostic Radiology, King Fahad Hospital, Al-Baha, Saudi Arabia
| | - Rawan Abdeen
- Department of Diagnostic Radiology, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Fahad Almutairi
- Department of Diagnostic Radiology, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah, Saudi Arabia
| |
Collapse
|
9
|
Tosun M, Uslu H. Comparison of superb microvascular imaging and shear wave elastography for assessing liver fibrosis in chronic hepatitis B. Ultrasonography 2022; 41:394-402. [PMID: 35026886 PMCID: PMC8942734 DOI: 10.14366/usg.21136] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Accepted: 11/25/2021] [Indexed: 11/13/2022] Open
Abstract
Purpose The present study investigated the effectiveness and applicability of superb microvascular imaging (SMI) in determining the degree of liver fibrosis noninvasively in comparison with shear wave elastography (SWE). Methods Ninety-eight consecutive patients with chronic hepatitis B who underwent ultrasound (US)-guided needle biopsy were examined using US combined with SMI and SWE. The predictive performance of the two US techniques in staging liver fibrosis and inflammation was compared with reference to the histological findings obtained from liver biopsy. The intraobserver and interobserver reproducibility of SMI in vascularity scores were evaluated. Results SWE values and SMI vascular scores were statistically significantly different among fibrosis stages (χ2(3)=76.3, χ2(3)=81.5, P<0.001). The SWE and SMI models significantly predicted fibrosis stages separately, and SMI scores alone predicted fibrosis stages better than SWE values (50.1% for SWE, 63.5% for SMI, P<0.001). A model with both SMI scores and SWE values together explained 73.2% of variance in fibrosis stages. When other clinical and laboratory predictors were added to the model (81.5%, P<0.001), SWE values and SMI scores remained the main predictors of fibrosis stages. SWE and SMI were also applicable in predicting inflammatory grades, explaining 31% and 34% of variance, respectively, and 37.7% when used together (P<0.001). Conclusion Both SWE and SMI had good diagnostic performance in determining the degree of liver fibrosis in chronic hepatitis B patients. The efficacy of SMI was better than that of SWE. SMI can improve diagnostic performance for staging liver fibrosis and shows potential for estimating necroinflammation of the liver.
Collapse
Affiliation(s)
- Mesude Tosun
- Department of Radiology, Kocaeli University School of Medicine, Kocaeli, Turkey
| | - Hande Uslu
- Department of Radiology, Kocaeli University School of Medicine, Kocaeli, Turkey
| |
Collapse
|
10
|
Kim EM, Park JW, Lee SM, Kim MJ, Ha HI, Kim SE, Kim ES, Kim YC, Lee K. Diagnostic Performance of 2-D Shear Wave Elastography on the Evaluation of Hepatic Fibrosis with Emphasis on Impact of the Different Region-of-Interest Methods. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:198-208. [PMID: 34756464 DOI: 10.1016/j.ultrasmedbio.2021.09.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 08/08/2021] [Accepted: 09/22/2021] [Indexed: 06/13/2023]
Abstract
The purpose of this study was to evaluate the impact of the different region-of-interest (ROI) methods of 2-D shear wave elastography (2-D SWE) on hepatic fibrosis diagnosis. In this retrospective study, 83 patients who underwent 2-D SWE with three ROI methods (a circle ROI, a box ROI and multiple ROIs in an elastogram) and transient elastography (TE) were included. Liver stiffness (LS) was measured five times with each ROI method. These LS values were compared, and their correlation with those obtained from TE was evaluated. The LS values obtained using the three different ROI methods differed statistically (p < 0.001). However, the LS values obtained using each ROI method of 2-D SWE were highly correlated with those obtained using TE (r > 0.7, p < 0.001). All three ROI methods of 2-D SWE had high areas under the receiver operating characteristic curve in diagnosing significant fibrosis and cirrhosis (0.841, 0.820 and 0.840, respectively; 0.962, 0.946 and 0.945, respectively). There were no significant differences in area under the receiver operating characteristic curve among the ROI methods of 2-D SWE. Regardless of the ROI method, 2-D SWE had high performance in diagnosing hepatic fibrosis.
Collapse
Affiliation(s)
- Eun Mi Kim
- Department of Radiology, Hallym University Sacred Heart Hospital, Anyang-si, Gyeonggi-do, Republic of Korea
| | - Ji-Won Park
- Gastroenterology and Hepatology, Department of Internal Medicine, Hallym University College of Medicine, Chuncheon, Republic of Korea;; Institute for Liver and Digestive Diseases, Hallym University, Chuncheon, Republic of Korea
| | - Sang Min Lee
- Department of Radiology, Hallym University Sacred Heart Hospital, Anyang-si, Gyeonggi-do, Republic of Korea.
| | - Min-Jeong Kim
- Department of Radiology, Hallym University Sacred Heart Hospital, Anyang-si, Gyeonggi-do, Republic of Korea
| | - Hong Il Ha
- Department of Radiology, Hallym University Sacred Heart Hospital, Anyang-si, Gyeonggi-do, Republic of Korea
| | - Sung-Eun Kim
- Gastroenterology and Hepatology, Department of Internal Medicine, Hallym University College of Medicine, Chuncheon, Republic of Korea;; Institute for Liver and Digestive Diseases, Hallym University, Chuncheon, Republic of Korea
| | - Eun Soo Kim
- Department of Radiology, Hallym University Sacred Heart Hospital, Anyang-si, Gyeonggi-do, Republic of Korea
| | - Young Chul Kim
- Department of Radiology, Hallym University Dongtan Sacred Heart Hospital, Gyeonggi-do, Republic of Korea
| | - Kwanseop Lee
- Department of Radiology, Hallym University Sacred Heart Hospital, Anyang-si, Gyeonggi-do, Republic of Korea
| |
Collapse
|
11
|
Cha J, Kim J, Ko J, Kim J, Eom K. Effects of Confounding Factors on Liver Stiffness in Two-Dimensional Shear Wave Elastography in Beagle Dogs. Front Vet Sci 2022; 9:827599. [PMID: 35155659 PMCID: PMC8830801 DOI: 10.3389/fvets.2022.827599] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Accepted: 01/06/2022] [Indexed: 12/12/2022] Open
Abstract
Background Two-dimensional shear wave elastography (2D-SWE) is a powerful technique that can non-invasively measure liver stiffness to assess hepatic fibrosis. Purpose This study aimed to identify the effects of confounding factors, including anesthesia, breathing, and scanning approach, on liver stiffness when performing 2D-SWE in dogs. Materials and Methods Nine healthy Beagle dogs were included in this study. Hepatic 2D-SWE was performed, and liver stiffness was compared between conscious and anesthetized states, free-breathing and breath-holding conditions, and intercostal and subcostal approaches. For the anesthetized state, the breath-holding condition was subdivided into seven phases, which included forced-expiration (5 and 10 mL/kg), end-expiration (0 cm H2O), and forced-inspiration (5, 10, 15, and 20 cm H2O), and liver stiffness was compared among these phases. Changes in liver stiffness were compared between intercostal and subcostal approaches according to breathing phases. Results No significant difference was observed in liver stiffness between the conscious and anesthetized states or between the free-breathing and breath-holding conditions. No significant difference was noted in liver stiffness among the breathing phases, except for forced-inspiration with high airway pressure (15 and 20 cm H2O in the intercostal approach and 10, 15, and 20 cm H2O in the subcostal approach), which was associated with significantly higher liver stiffness (p < 0.05). Liver stiffness was significantly higher in the subcostal approach than in the intercostal approach (p < 0.05). Changes in liver stiffness were significantly higher in the subcostal approach than in the intercostal approach in all forced-inspiratory phases (p < 0.05). Conclusion In conclusion, when performing 2D-SWE in dogs, liver stiffness is unaffected by anesthesia and free-breathing. To avoid inadvertent increases in liver stiffness, the deep inspiratory phase and subcostal approach are not recommended. Thus, liver stiffness should be interpreted considering these confounding factors.
Collapse
|
12
|
Tosco A, Sepe A, Castaldo A, Catzola A, Cimbalo C, Angelini V, Vallone G, Buzzetti R, Raia V, Caprio MG. Non-invasive tools for detection of liver disease in children and adolescents with cystic fibrosis. Transl Pediatr 2021; 10:2952-2959. [PMID: 34976761 PMCID: PMC8649592 DOI: 10.21037/tp-21-68] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/20/2021] [Accepted: 08/12/2021] [Indexed: 11/06/2022] Open
Abstract
BACKGROUND Cystic fibrosis (CF) is a multi-organ genetic disease caused by mutations in the cystic fibrosis transmembrane conductance regulator (CFTR) gene which encodes the CFTR protein. CF-associated liver disease (CFLD) is a common complication; diagnosis is based on clinical, laboratory findings and abdominal imaging. However, non-invasive diagnostic approaches are needed to early detect CFLD, its progression and severity. Recent studies demonstrate a possible role of point shear wave elastography (p-SWE) with liver stiffness measurement (LSM) as a tool for CFLD diagnosis also in children. This non-invasive technique measures liver stiffness to assess liver fibrosis and is suggested to be less operator-dependent compared to ultrasonography. Aim of our prospective observational study is to investigate the role of p-SWE with LSM for CFLD diagnosis in children and adolescents with CF and to compare this finding with aspartate aminotransferase to platelet ratio index (APRI), fibrosis index based on four factors (FIB-4) and gamma-glutamyl-transpeptidase to platelet ratio (GPR) indices. METHODS Fifty-nine children with CF, who had routinely undergone abdominal imaging, were consecutively enrolled. Laboratory findings and clinical data were recorded, as abdominal ultrasound and shear wave elastography at baseline. The cases were divided into two groups based on collected data and classified as CFLD and CFnoLD (without liver disease) according to Debray criteria. APRI, FIB-4 and GPR fibrosis indices were also evaluated. RESULTS Twenty-four/59 (40.7%) were defined as CFLD. LSM test is superior to the APRI (P<0.001), the FIB-4 test (P=0.001) and the GPR test for early detection of liver fibrosis. LSM had an area under receiver operating characteristic (ROC) curve =0.818 (95% CI: 0.702-0.934) compared with APRI (0.571, 95% CI: 0.421-0.722), FIB-4 (0.656, 95% CI: 0.511-0.801) and GPR (0.632, 95% CI: 0.485-0.779). At a cut-off of ≥6.2 LSM show a sensitivity of 75.0% and a specificity of 88.6%. CONCLUSIONS LSM by transient p-SWE is a non-invasive, highly accessible, reliable, and reproducible test that can be used to assess early detection of liver fibrosis and its severity in children and adolescents with CF, limiting the use of liver biopsy. These preliminary observations point to the need of larger study population to confirm our data.
Collapse
Affiliation(s)
- Antonella Tosco
- Pediatric Unit, Department of Translational Medical Sciences, Regional Cystic Fibrosis Center, Federico II University of Naples, Naples, Italy
| | - Angela Sepe
- Pediatric Unit, Department of Translational Medical Sciences, Regional Cystic Fibrosis Center, Federico II University of Naples, Naples, Italy
| | - Alice Castaldo
- Pediatric Unit, Department of Translational Medical Sciences, Regional Cystic Fibrosis Center, Federico II University of Naples, Naples, Italy
| | - Andrea Catzola
- Pediatric Unit, Department of Translational Medical Sciences, Regional Cystic Fibrosis Center, Federico II University of Naples, Naples, Italy
| | - Chiara Cimbalo
- Pediatric Unit, Department of Translational Medical Sciences, Regional Cystic Fibrosis Center, Federico II University of Naples, Naples, Italy
| | - Valentina Angelini
- Department of Oncoematologia, Diagnostica per immagini e morfologica e Medicina Legale, University of Naples Federico II, Naples, Italy
| | - Gianfranco Vallone
- Department Life and Health "V. Tiberio", University of Molise, Campobasso, Italy
| | | | - Valeria Raia
- Pediatric Unit, Department of Translational Medical Sciences, Regional Cystic Fibrosis Center, Federico II University of Naples, Naples, Italy
| | | |
Collapse
|
13
|
Taibbi A, Petta S, Matranga D, Caruana G, Cannella R, Busè G, Marco VD, Midiri M, Bartolotta TV. Liver stiffness quantification in biopsy-proven nonalcoholic fatty liver disease patients using shear wave elastography in comparison with transient elastography. Ultrasonography 2020; 40:407-416. [PMID: 33561928 PMCID: PMC8217807 DOI: 10.14366/usg.20147] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Accepted: 12/18/2020] [Indexed: 12/14/2022] Open
Abstract
Purpose This study prospectively assessed the performance of liver stiffness measurements using point shear-wave elastography (p-SWE) in comparison with transient elastography (TE) in patients with biopsy-proven nonalcoholic fatty liver disease (NAFLD). Methods Fifty-six consecutive adult patients with a histological diagnosis of NAFLD prospectively underwent TE and p-SWE on the same day. The median of 10 measurements (SWE-10), the first five (SWE-5), and the first three (SWE-3) measurements were analyzed for p-SWE. Liver biopsy was considered as the reference standard for liver fibrosis grade. Receiver operating characteristic (ROC) curves and areas under the ROC curves (AUROCs) were calculated to assess the performance of TE and p-SWE for the diagnosis of significant (F2-F4) and advanced fibrosis (F3-F4). Results Forty-six patients (27 men, 19 women; mean age, 54.7±9.1 years) had valid p-SWE and TE measurements. Twenty-seven patients (58.7%) had significant fibrosis and 18 (39.1%) had advanced fibrosis. For significant fibrosis, both SWE-10 (AUROC, 0.787; P=0.002) and SWE-5 (AUROC, 0.809; P=0.001) provided higher diagnostic performance than TE (AUROC, 0.719; P=0.016) and SWE-3 (AUROC, 0.714; P=0.021), albeit without statistical significance (P=0.301). For advanced fibrosis, SWE-5 showed higher diagnostic performance (AUROC, 0.809; P<0.001) than TE (AUROC, 0.799; P<0.001), SWE-10 (AUROC, 0.797; P<0.001), and SWE-3 (AUROC, 0.736; P=0.003), although the differences were not statistically significant (P=0.496). The optimal SWE-10 and SWE-5 cutoff values were ≥8.4 and ≥7.8 for significant fibrosis, and ≥9.1 and ≥8.8 for advanced fibrosis, respectively. Conclusion TE and p-SWE showed similar performance for the diagnosis of significant and advanced fibrosis in NAFLD patients.
Collapse
Affiliation(s)
- Adele Taibbi
- Section of Radiology - BiND, University Hospital "Paolo Giaccone," Palermo, Italy
| | - Salvatore Petta
- Section of Gastroenterology and Hepatology, Department of Health Promotion Sciences Maternal and Infant Care, Internal Medicine and Medical Specialties, PROMISE, University of Palermo, Palermo, Italy
| | - Domenica Matranga
- Department of Health Promotion Sciences, Maternal and Infant Care, Internal Medicine and Medical Specialties "G. D'Alessandro," University of Palermo, Palermo, Italy
| | - Giovanni Caruana
- Section of Radiology - BiND, University Hospital "Paolo Giaccone," Palermo, Italy
| | - Roberto Cannella
- Section of Radiology - BiND, University Hospital "Paolo Giaccone," Palermo, Italy
| | - Gabriele Busè
- Section of Radiology - BiND, University Hospital "Paolo Giaccone," Palermo, Italy
| | - Vito Di Marco
- Section of Gastroenterology and Hepatology, Department of Health Promotion Sciences Maternal and Infant Care, Internal Medicine and Medical Specialties, PROMISE, University of Palermo, Palermo, Italy
| | - Massimo Midiri
- Section of Radiology - BiND, University Hospital "Paolo Giaccone," Palermo, Italy
| | - Tommaso Vincenzo Bartolotta
- Section of Radiology - BiND, University Hospital "Paolo Giaccone," Palermo, Italy.,Department of Radiology, Fondazione Istituto Giuseppe Giglio, Cefalù (Palermo), Italy
| |
Collapse
|