1
|
Taco Boltje JW, Carvalho Mota MT, Vriesendorp MD, Vonk ABA, Groenwold RHH, Klautz RJM, Velders BJJ. The use of pledget-reinforced sutures during surgical aortic valve replacement: A systematic review and meta-analysis. INTERNATIONAL JOURNAL OF CARDIOLOGY. HEART & VASCULATURE 2024; 54:101494. [PMID: 39263410 PMCID: PMC11387225 DOI: 10.1016/j.ijcha.2024.101494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2024] [Revised: 08/11/2024] [Accepted: 08/12/2024] [Indexed: 09/13/2024]
Abstract
Objective Literature presents conflicting results on the pros and cons of pledget-reinforced sutures during surgical aortic valve replacement (SAVR). We aimed to investigate the effect of pledget-reinforced sutures versus sutures without pledgets during SAVR on different outcomes in a systematic review and meta-analysis. Methods A literature search was performed in five different medical literature databases. Studies must include patients undergoing SAVR and must compare any pledget-reinforced with any suturing technique without pledgets. The primary outcome was paravalvular leakage (PVL), and secondary outcomes comprised thromboembolism, endocarditis, mortality, mean pressure gradient (MPG) and effective orifice area (EOA). Results were pooled using a random-effects model as risk ratios (RRs) or mean differences (MDs) for which the no pledgets group served as reference. Results Nine observational studies met the inclusion criteria. The risk of bias was critical in seven studies, and high and moderate in two other. The pooled RR for moderate or greater PVL was 0.59 (95 % confidence interval [CI] 0.13, 2.73). The pooled RR for mortality at 30-days was 1.02 (95 % CI 0.48, 2.18) and during follow-up was 1.15 (95 % CI 0.67, 2.00). For MPG and EOA at 1-year follow-up, the pooled MDs were 0.60 mmHg (95 % CI -4.92, 6.11) and -0.03 cm2 (95 % CI -0.18, 0.12), respectively. Conclusions Literature on the use of pledget-reinforced sutures during SAVR is at high risk of bias. Pooled results are inconclusive regarding superiority of either pledget-reinforced sutures or sutures without pledgets. Hence, there is no evidence to support or oppose the use of pledget-reinforced sutures.
Collapse
Affiliation(s)
- J W Taco Boltje
- Department of Cardiothoracic Surgery, Amsterdam University Medical Center Location AMC, Amsterdam, the Netherlands
- Department of Cardiothoracic Surgery, Leiden University Medical Center, Leiden, the Netherlands
| | - Mathijs T Carvalho Mota
- Department of Cardiothoracic Surgery, Amsterdam University Medical Center Location AMC, Amsterdam, the Netherlands
| | - Michiel D Vriesendorp
- Department of Cardiothoracic Surgery, Amsterdam University Medical Center Location AMC, Amsterdam, the Netherlands
- Department of Cardiothoracic Surgery, Leiden University Medical Center, Leiden, the Netherlands
| | - Alexander B A Vonk
- Department of Cardiothoracic Surgery, Amsterdam University Medical Center Location AMC, Amsterdam, the Netherlands
- Department of Cardiothoracic Surgery, Leiden University Medical Center, Leiden, the Netherlands
| | - Rolf H H Groenwold
- Department of Clinical Epidemiology, Leiden University Medical Center, Leiden, the Netherlands
- Department of Biomedical Data Science, Leiden University Medical Center, Leiden, the Netherlands
| | - Robert J M Klautz
- Department of Cardiothoracic Surgery, Amsterdam University Medical Center Location AMC, Amsterdam, the Netherlands
- Department of Cardiothoracic Surgery, Leiden University Medical Center, Leiden, the Netherlands
| | - Bart J J Velders
- Department of Cardiothoracic Surgery, Leiden University Medical Center, Leiden, the Netherlands
- Department of Clinical Epidemiology, Leiden University Medical Center, Leiden, the Netherlands
| |
Collapse
|
2
|
Arabkhani B, Gonthier S, Lorenz V, Deschamps S, Jahanyar J, Boute M, Vancraeynest D, Mastrobuoni S, Khoury GE, de Kerchove L. Continuous or interrupted pledgeted suture technique in stented bioprosthetic aortic valve replacement: a comparison of in-hospital outcomes. J Cardiothorac Surg 2024; 19:174. [PMID: 38576006 PMCID: PMC10996201 DOI: 10.1186/s13019-024-02754-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Accepted: 03/29/2024] [Indexed: 04/06/2024] Open
Abstract
BACKGROUND There is ambiguity in the literature regarding the continuous suture technique (CST) for aortic valve replacement (AVR). At our center, there has been a gradual shift towards CST over the interrupted pledgeted technique (IPT). This study aims at comparing outcomes for both techniques. METHODS We performed a retrospective analysis of a single-center study of patients undergoing AVR between January 2011 and July 2020. Patients were divided into two groups: Continuous suture technique and interrupted pledget-reinforced sutures. The pre-operative and In-hospital clinical characteristics and echocardiographic hemodynamics (i.e. transvalvular gradients and paravalvular leakage) were compared between CST and IPT. RESULTS We compared 791 patients with CST to 568 patients with IPT (median age: 73 and 74 years, respectively, p = 0.02). In CST there were 35% concomitant procedure vs. 31% in IPT (p = 0.16). Early mortality was 3.2% in CST versus 4.8% in IPT (p = 0.15), and a second cross-clamp due to a paravalvular-leak in 0.5% vs. 1.2%, respectively (p = 0.22). The CST was not associated with new-onset conduction-blocks mandating pacemaker implants(OR 1.07, 95% CI 0.54-2.14; P = 0.85). The postoperative gradients on echocardiography were lower in CST compared to IPT, especially in smaller annuli (peak gradients: 15.7mmHg vs. 20.5mmHg, in valve size < 23 mm, p < 0.001). CONCLUSIONS The continuous suture technique was associated with lower postoperative gradients and shorter cross-clamp time compared to interrupted pledgeted technique. Differences in paravalvular leaks were non-significant, although slightly less in the continuous suture technique. There were no further differences in valve-related complications. Hence, continues suture technique is safe, with better hemodynamics compared to the interrupted pledgeted technique. This may be of clinical importance, especially in smaller size annular size.
Collapse
Affiliation(s)
- Bardia Arabkhani
- Department of Cardiovascular and Thoracic surgery, UC Louvain Saint Luc, Brussels, Belgium.
- Department of Cardio-Thoracic Surgery, Erasmus Medical Center (EMC), Dr. Molewaterplein 40, Rotterdam, 3015 GD, The Netherlands.
| | - Sebastien Gonthier
- Department of Cardiovascular and Thoracic surgery, UC Louvain Saint Luc, Brussels, Belgium
| | - Veronica Lorenz
- Department of Cardiovascular and Thoracic surgery, UC Louvain Saint Luc, Brussels, Belgium
| | - Samuel Deschamps
- Department of Cardiovascular and Thoracic surgery, UC Louvain Saint Luc, Brussels, Belgium
| | - Jama Jahanyar
- Department of Cardiovascular and Thoracic surgery, UC Louvain Saint Luc, Brussels, Belgium
- Division of Cardiothoracic Surgery, Department of Surgery, Queen's Heart Institute, John A. Burns School of Medicine, University of Hawaii, Honolulu, HI, USA
| | - Marin Boute
- Department of Cardiovascular Diseases, Cliniques Universitaires St. Luc, and IREC/CARD UCLouvain, Brussels, B-1200, Belgium
| | - David Vancraeynest
- Department of Cardiovascular Diseases, Cliniques Universitaires St. Luc, and IREC/CARD UCLouvain, Brussels, B-1200, Belgium
| | - Stefano Mastrobuoni
- Department of Cardiovascular and Thoracic surgery, UC Louvain Saint Luc, Brussels, Belgium
| | - Gebrine El Khoury
- Department of Cardiovascular and Thoracic surgery, UC Louvain Saint Luc, Brussels, Belgium
| | - Laurent de Kerchove
- Department of Cardiovascular and Thoracic surgery, UC Louvain Saint Luc, Brussels, Belgium
| |
Collapse
|
3
|
Desai NB, Bhat PSS, M CS, S S, Praveen CH, Moharana AK, Ts D. Clinical Equivalence of Trubond® and Ethibond® Braided Polyester Sutures for Valvular Prosthesis Fixation During Aortic or Mitral Valve Replacement: A Single-Blind Randomized Controlled Trial. Cureus 2023; 15:e41117. [PMID: 37519509 PMCID: PMC10382791 DOI: 10.7759/cureus.41117] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/28/2023] [Indexed: 08/01/2023] Open
Abstract
Background Paravalvular leak (PVL) following valve replacement is a serious cardiovascular complication that increases morbidity and mortality. Valve replacement with the interrupted suture technique using polyester suture provides adequate tensile strength and reduces the probability of tissue reaction. This study compared the clinical equivalence of Trubond®(Healthium) and Ethibond® (Ethicon, Johnson & Johnson) braided polyester sutures for valvular prosthesis fixation using interrupted suturing, with respect to the proportion of subjects having PVL after aortic valve (AV) or mitral valve (MV) replacement. Methodology Patients undergoing AV/MV replacement were enrolled and randomized in this study. The primary endpoint of this prospective, multicentric, two-arm, randomized (1:1), parallel-group, single-blind study (December 2020-October 2022) was the presence of PVL in Trubond® (n = 40) and Ethibond® (n = 42) groups within 26 weeks of surgery. The secondary endpoints included event rate of all-cause mortality, cardiac death, stroke, myocardial infarction, re-hospitalization, re-intervention, wound infection, operative time, intraoperative suture parameters, postoperative hospital stay, time to resume normal activities and work, quality of life, patient satisfaction, and adverse events in both groups. Results Patients who underwent AV/MV replacement and were followed up until 26 weeks had no incidence of PVL or other postoperative complications. No requirement for readmission or re-intervention was noted in both groups. Intraoperative suture handling characteristics, operative time, and hospital stay were also comparable between the groups. With each follow-up, subjects in both groups exhibited improved postoperative functional abilities, quality of life, and health status. Conclusions Trubond® braided polyester suture is clinically equivalent to Ethibond® braided polyester suture. Trubond® suture is safe and effective for valvular prosthesis fixation in patients undergoing AV or MV replacement.
Collapse
Affiliation(s)
- Neelam B Desai
- Cardio Vascular and Thoracic Surgery, Sri Sathya Sai Institute of Higher Medical Sciences, Puttaparthi, IND
| | - P S Seetharama Bhat
- Cardio Vascular and Thoracic Surgery, Sri Jayadeva Institute of Cardiovascular Sciences and Research, Bengaluru, IND
| | - Chandra Sena M
- Cardio Vascular and Thoracic Surgery, Sri Jayadeva Institute of Cardiovascular Sciences and Research, Bengaluru, IND
| | - Siddharth S
- Cardio Vascular and Thoracic Surgery, Sri Sathya Sai Institute of Higher Medical Sciences, Puttaparthi, IND
| | - C H Praveen
- Cardio Vascular and Thoracic Surgery, Sri Sathya Sai Institute of Higher Medical Sciences, Puttaparthi, IND
| | | | - Deepak Ts
- Clinical Affairs, Healthium Medtech Limited, Bengaluru, IND
| |
Collapse
|
4
|
Yount KW, Hawkins RB, Mehaffey JH, Teman NR, Yarboro LT, Kern JA, Ailawadi G. Aortic valve biologic protheses: A cohort comparison of premature valve failure. J Card Surg 2022; 37:1224-1229. [PMID: 35245397 DOI: 10.1111/jocs.16328] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 11/18/2021] [Accepted: 11/24/2021] [Indexed: 11/29/2022]
Abstract
BACKGROUND Recent reports suggest an increased rate of early structural valve degeneration (SVD) in the Trifecta bioprosthesis (Abbott Cardiovascular). We sought to compare the intermediate-term outcomes of the Magna (Edwards Life Sciences) and Trifecta valves. METHODS All surgical aortic valve replacements (SAVRs) with Trifecta or Magna/Magna Ease bioprostheses at an academic medical center were extracted from an institutional database. Patients who survived until after discharge (2011-2019) were included. The primary outcome was valve failure for any reason requiring reintervention or contributing to death, identified by reintervention or review of cause of death. Time to failure was estimated with Kaplan-Meier analysis and Cox Proportional Hazards Modeling. RESULTS Out of 1444 patients, 521 (36%) underwent Trifecta and 923 (64%) underwent Magna implantation with a median follow-up of 27.6 months. Trifecta patients had larger median valve size (25 vs. 23 mm, p < .001) and lower median gradient (8.0 vs. 10.9 mmHg, p < .001). Trifecta patients had higher 48-month estimated failure rates (20.2 ± 7.6% vs. 2.6 ± 0.7%, p < .0001), with failure rates of 21.4 versus 9.2 failures per 1000 person-years (p < .001). After risk-adjustment, Trifecta patients had a 5.3 times hazard of failure (95% confidence interval: 2.78-12.34, p < .001) compared to Magna patients. Only Trifecta valves failed due to sudden aortic regurgitation, 8 out of 521 (1.5%). CONCLUSION Despite lower postoperative mean gradients, the Trifecta bioprosthesis may have an increased risk of intermediate-term SVD. Further research is warranted to confirm the potential for sudden valve failure.
Collapse
Affiliation(s)
- Kenan W Yount
- Division of Thoracic and Cardiovascular Surgery, University of Virginia, Charlottesville, Virginia, USA
| | - Robert B Hawkins
- Department of Cardiac Surgery, University of Michigan, Ann Arbor, Michigan, USA
| | - J Hunter Mehaffey
- Division of Thoracic and Cardiovascular Surgery, University of Virginia, Charlottesville, Virginia, USA
| | - Nicholas R Teman
- Division of Thoracic and Cardiovascular Surgery, University of Virginia, Charlottesville, Virginia, USA
| | - Leora T Yarboro
- Division of Thoracic and Cardiovascular Surgery, University of Virginia, Charlottesville, Virginia, USA
| | - John A Kern
- Division of Thoracic and Cardiovascular Surgery, University of Virginia, Charlottesville, Virginia, USA
| | - Gorav Ailawadi
- Department of Cardiac Surgery, University of Michigan, Ann Arbor, Michigan, USA
| |
Collapse
|
5
|
OUP accepted manuscript. Eur J Cardiothorac Surg 2022; 62:6563500. [DOI: 10.1093/ejcts/ezac195] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Revised: 02/23/2022] [Accepted: 03/15/2022] [Indexed: 11/13/2022] Open
|
6
|
Saisho H, Scharfschwerdt M, Schaller T, Reil JC, Ensminger S, Fujita B, Aboud A. An ex vivo evaluation of two different suture techniques for the Ozaki aortic neocuspidization procedure. Interact Cardiovasc Thorac Surg 2021; 33:518-524. [PMID: 34089604 DOI: 10.1093/icvts/ivab138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 03/11/2021] [Accepted: 03/31/2021] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVES We investigated the Ozaki procedure using a single interrupted suture technique (SST) and compared this with the standard continuous suture technique (CST) with regard to hydrodynamic valve performance. In addition, both techniques were compared with the native aortic valve (NAV). METHODS Effective orifice area, mean pressure gradient and leakage volume were evaluated in the NAV as well as after an Ozaki procedure using SST or CST in fresh swine aortic roots using a mock circulation loop. The NAV, SST and CST were evaluated under 4 defined hydrodynamic conditions. RESULTS Both suture techniques resulted in a similar effective orifice area under all conditions [for stroke volume of 70 ml: SST: 1.50 (1.35-1.87) vs CST: 1.57 (1.41-1.72) cm2, P = 0.8] and there were no significant differences between both suture techniques and the NAV (P > 0.05). Regarding mean pressure gradient, the Ozaki procedure with SST and CST showed no significant differences [7.23 (5.53-8.91) vs 7.04 (6.65-7.60) mmHg, P = 0.72] and there was no significant difference between both suture techniques and the NAV (P > 0.1). In leakage volume, there was no significant difference between SST and CST [4.49 (3.91-4.99) vs CST: 4.23 (3.58-4.87) ml/stroke, P = 0.34]. CONCLUSIONS The Ozaki procedure with SST performed similarly to that with CST with regard to hydrodynamic performance. Our results suggest that the Ozaki procedure can be performed with SST instead of CST, which may be useful in patients with limited surgical exposure, such as a small annulus.
Collapse
Affiliation(s)
- Hiroyuki Saisho
- Department of Cardiac and Thoracic Vascular Surgery, University Hospital of Schleswig-Holstein, Lübeck, Germany.,University of Lübeck, Lübeck, Germany
| | - Michael Scharfschwerdt
- Department of Cardiac and Thoracic Vascular Surgery, University Hospital of Schleswig-Holstein, Lübeck, Germany.,University of Lübeck, Lübeck, Germany
| | - Tim Schaller
- Department of Cardiac and Thoracic Vascular Surgery, University Hospital of Schleswig-Holstein, Lübeck, Germany.,University of Lübeck, Lübeck, Germany
| | - Jan Christian Reil
- University of Lübeck, Lübeck, Germany.,Department of Medicine II, University Hospital of Schleswig-Holstein, Lübeck, Germany
| | - Stephan Ensminger
- Department of Cardiac and Thoracic Vascular Surgery, University Hospital of Schleswig-Holstein, Lübeck, Germany.,University of Lübeck, Lübeck, Germany
| | - Buntaro Fujita
- Department of Cardiac and Thoracic Vascular Surgery, University Hospital of Schleswig-Holstein, Lübeck, Germany.,University of Lübeck, Lübeck, Germany
| | - Anas Aboud
- Department of Cardiac and Thoracic Vascular Surgery, University Hospital of Schleswig-Holstein, Lübeck, Germany.,University of Lübeck, Lübeck, Germany
| |
Collapse
|
7
|
Stamou SC, Moeller EA, Nores MA. Continuous Suture Technique for Aortic Valve Replacement: Technical Considerations and Controversies. Int J Angiol 2019; 28:64-68. [PMID: 30880896 DOI: 10.1055/s-0038-1676967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022] Open
Abstract
Continuous suture technique (CST) for aortic valve replacement (AVR) is a simple, secure, and fast surgical technique that has been shown to significantly decrease cross clamp time and cardiac bypass time, ultimately resulting in decreased myocardial ischemic injury, operation time, and hospital stay. However, previous studies have reported increased risk of periprosthetic regurgitation with CST for AVR. We describe our technique for AVR using CST in 100 patients with low complication rate and no perioperative paravalvular aortic insufficiency.
Collapse
Affiliation(s)
- Sotiris C Stamou
- Department of Thoracic and Cardiovascular Surgery, JFK Medical Center, Atlantis, Florida
| | - Ellie A Moeller
- Department of Thoracic and Cardiovascular Surgery, JFK Medical Center, Atlantis, Florida
| | - Marcos A Nores
- Department of Thoracic and Cardiovascular Surgery, JFK Medical Center, Atlantis, Florida
| |
Collapse
|
8
|
Lee MK, Choi JB, Kim NY. Continuous Suture Technique for Aortic Valve Replacement. Tex Heart Inst J 2018; 45:121. [PMID: 29844750 DOI: 10.14503/thij-18-6607] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Mi Kyung Lee
- Department of Thoracic and Cardiovascular Surgery, Wonkwang University Medical School, Iksan, Chonbuk, Republic of Korea
| | - Jong Bum Choi
- Department of Thoracic and Cardiovascular Surgery, Wonkwang University Medical School, Iksan, Chonbuk, Republic of Korea
| | - Nan Yeol Kim
- Department of Thoracic and Cardiovascular Surgery, Wonkwang University Medical School, Iksan, Chonbuk, Republic of Korea
| |
Collapse
|
9
|
Affiliation(s)
- Mi Kyung Lee
- Department of Thoracic and Cardiovascular Surgery, Wonkwang University Medical School, Iksan, Chonbuk, Republic of Korea
| | - Jong Bum Choi
- Department of Thoracic and Cardiovascular Surgery, Wonkwang University Medical School, Iksan, Chonbuk, Republic of Korea
| | - Nan Yeol Kim
- Department of Thoracic and Cardiovascular Surgery, Wonkwang University Medical School, Iksan, Chonbuk, Republic of Korea
| |
Collapse
|